HomeMy WebLinkAboutFormBoardEXISTING 0 WELL LOT t ,Z),, bo S,L 1000 Dot iO A TO, SITE PLAN NOTES - Is COUNTY WATER + SEWER NOT AVAILABLE FOR THI5 PARCEL. 2- A DRIVEWAY MAXIMUM SLOPE 15 NOT TO EXCEED A 107. GRADE 3- FIRST FLOOR ELEVATION ESTABLISHED WITHOUT A HEALTH DEPARTMENT PERMIT. 4- PROPOSED DRAINAGE PLAN DESIGNED TO MEET FLORIDA BUILDING CODE. RESIDENTIAL REQUIREMENT5.CR401.3) 5. ALL SLOPES AROUND THE PROP05ED STRUCTURE ARE NOT TO EXCEED THE MAXIMUM ALLOWABLE SLOPE GRADE OF 4,1 G, WHEN A CULVERT 15 REQUIRED THE INVERTS ARE TO BE SET BY PUBLIC WORKS DEPARTMENT AND WILL BE DETERMINED AT STAKE AND GRADE. 7- ALL 5TORMWATER RUNOFF 15 NOT TO IMPACT THE ADJACENT PROPERTIES AND MUST MEET A MINIMUM OF 1Z LONGITUDINAL SLOPE OR OTHERWISE ACCEPTED. 8l PLOT PLANS ARE NOT TO BE USED FOR GON5TRUGTION LAYOUT PURPOSES WITHOUT APPROVED BUILDING PERMITS. OCCUPIED F.F.EL.=21.2 I LEGEND A OF SURVEY ABBREVIATIONS HEAD WALL DELTA ANGLE H.W. A/C AIR CONDITIONER L. LENGTH AVE. AVENUE 7Q( LIGHT POLE AVG. AVERAGE M. MEASURED BH. HEARING BASE M.H. MANHOLE i BASELINE M,H,W.L. MEAN HIGH WATER LINE H.M. BENCH MARK MON. MONUMENT ELK. BLOCK N&D NAIL 6 DISK BLVD. BOULEVARD N. NORTH H.S.L. BUILDING SETBACK LINE No, NUMBER C. CURVE N.IC, NOT INCLUDED C.B, CHORD BEARING O.H.W. OVERHEAD WIRES C.B.S. CONCRETE BLOCK PG. PAGE D STRUCTURE CHORD DISTANCE P.K. PARKER KALON NAIL CENTERLINE P. PLATP.C. C.L.F. CHAIN LINK FENCE POINT OF CURVATURE C.D. CHORD DISTANCE P.C.P. PERMANENT CONTROL POINT C.M. CONCRETE MONUMENT P POINT OINTERSECTION C.M.P. CORRUGATED METAL PIPE P,I L, PROPERTY LINE C CONCRETE P M, POWER METER CAaR.. COUNTY ROAD P.D.B. POINT OF BEGINNING CT, COURT P.M.C. POINT OF COMMENCEMENT C/S CONCRETE SLAB PRC POINT OF REVERSE CURVE CUR. CORNER P.R.M. PERMANENT REFERENCE MONUMENT D. DEED PROP. PROPOSED D.B. DEED BOOK CU.) POWER POLE DEP DEPARTMENT OF RAD. RADIAL OR RADIUS ENVIRONMWAL PROTECTION R/W RIGHT OF WAY DIST. DISTANCE S. SOUTH DNR DEPARTMENT OF SEC. SECTION NATURAL RESOURCES SOFT, SQUARE FEET DR. DRIVE S.R. STATE ROAD E. EAST ST. STREET ESMT. EASEMENT STAB STATION ELEC. ELECTRICAL STRUC, STRUCTURE EL. ELEVATION SUB. SUBDIVISION E.O.W. EDGE OF WATER T,B.M, TEMPORARY BENCH MARK FND F.F. FINISHED FLOOR TELE. TELEPHONE FND. FOUND T.O.H. TOP OF BANK FND IR 589°40'00T 59.50' 1/2' IP i7 FPL FIRE HYDRANT FLORIDA POWER TOPO. TR. TOPOGRAPHICAL TRACT 0.4'N I.P. 6 LIGHT IRON PIPE TWSP. TOWNSHIP I.R. IRON ROD U 6 D UTILITY 6 DRAINAGE INV. INVERT U.R. UNREADABLE IRR, IRRIGATION W. WEST GOV'T GOVERNMENT ® WATER METER GR, GRADE WV WATER VALVE GND. GROUND COMBINED LOTS FND IR` 0.2'5 BELL5OUTH�, BOX 9.2_ -SET TBM ON PK EL =19.57' N89040'00"W 59.50' MATANZA S AVE. C 70' R/W ) 18' PAVEMENT 0 n N L17 c-1 CC! 0 0 FND 1/2' IF 0.7'N. 0.9'W EXISTING ® WELL LOT 2 OCCUPIED F.F.EL.=20.G' EXI5TING STRUCTURE F �__o 2' SEPTIC TANK LID5 4. 11%02' I -Cif' 1 _j 70 HORZ. HORIZONTAL H.P. HIGH POINT LEGAL DESCRIPTION, ALL OF LOT 3, BLOCK C HARMONY HEIGHT5 ACCORDING TO THE PLAT THEREOF A5 RECORDED IN PLAT BOOK 8. PAGE 38 OF THE PUBLIC RECORDS OF 5T. LUCIE CO.. FLORIDA. CONTAINING 0.21 ACRES MORE OR LE55 SURVEY NOTES: 1. LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR RIGHTS -OF -WAY AND/OR EASEMENTS OF RECORD. 2. THIS SURVEY IS CERTIFIED ONLY TO THE BELOW NAMED INDIVIDUALS 3. LEGAL DESCRIPTION SUPPLIED BY CLIENT. 4. SQ. FT. OF HOUSE (IF SHOWN) SUPPLIED BY CLIENT. 5. NO STRUCTURES OR UTILITIES THAT ARE BENEATH THE SURFACE HAVE BEEN LOCATED. 6. ALL SET CAPS LABELED PSM WEH 4416 ARE SUPPORTED WITH AN 18" LONG #5 REBAR ALL FOUND CAPS ARE A 5/8" ROD WITH A CAP AS LABELED ON SURVEY. ALL FOUND REBAR ARE A 5/8" ROD UNLESS OTHERWISE NOTED. 7. ALL LOT DIMENSIONS ARE PLAT AND MEASURED UNLESS OTHERWISE NOTED. 8. BEARING BASE ON THE EAST LINE OF LOT 3. 9. ORIGINAL IRC BM: SHELL EL.=19.12' NAVD 88 10. ELEVATIONS (IF SHOWN) HEREON ARE BASED ON N.A.V.D. (1988), UNLESS OTHERWISE NOTED. CERTIFIED T®: JEFF GEORGE JR. W � :I✓ a`> LSJLU U; .2/-073�v THIS SURVEY MAP AND REPORT OR COPIES THEREOF ARE SURVEY TYPE: FLOOD ZONE: X NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED, BOUNDARY/SITE: DATE: REVISIONS: BY. EFFECTIVE DATE: 2/16/12 SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER, PNL NO.: 12111CO160J K.MA En ineerin & Surve In LLC CHECKED BY: W.E.H. 1/20/21 ADD WATER METER SMD® INDICATES EXISTING ELEVATION v �0 INDICATES PROPOSED ELEVATION Surveying, DRAWN BY: SMD 4/12/21 REMOVED PROP WELL PER CLIENT LEH 1150-1 INDICATES AS -BUILT ELEVATION ELEVATIONS ARE FOR CAL.C, Consulting Engineers & Surveyors FIELD BOOK: 389 8/27/21 REV. PER CO. LETT. SMD THERESES AREONOYWELLS OR SEPTICS PAGE NO. WITHIN 100' OF PROPERTY UNLESS 2345 14th Ave. Suite 3 Vero Beach, Fl. 32960 2rf4 1 1/19/22 FORM BOARD LOCATION JEK SHOWN, FIELD DAIS: 12/10�201 — - PROPOSED SPROPOSED ONTOUR WALE LINE ✓ t °I %2 �" Phone: (772) 569-6680 Fax: (772) 770-3446 E-Mail: survey@kmafl.com -w-►INDICATES LOT DRAINAGE WILLIAM[ E. HA T:IRST r DAB �SCAM- 1 M=20� LIVILIVII INDICATES NDI ATESsq f{INFIELD PROrE88IONA1, L"D NUMMXOR as U"PIOR Certificate of Authorization Number: L.B.8351 LOT AREA 9.062 sn,ft rLORMA REG18TRA'TION NO "is ENGINEERINGSURVEYING � 'N0. 21-2231 ®=SEPTIC TANK 2C-338)