Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFING 5/4/2021 Florida Building Code Online Business & iYl ,I tIF, _ ProfessionalRegulation r BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts Publications Contact Us BCIS Site Map Links Search bpr Product Approval` USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail OFFICE OF THE FL# FL25621-R2 SFCRETARY Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 flvalidation@yahoo.com Authorized Signature Richard McKuhen flvalidation@yahoo.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the David Eng Evaluation Report Florida License PE-81377 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By James R Wally, PE Validation Checklist- Hardcopy Received Certificate of Independence FL25621 R2 COI 26ga SnapMax plywood.pdf Referenced Standard and Year(of Standard) Standard Year TAS 100 1995 TAS 125 2003 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckBl071JGil iolYgdSepol aWOZICDw56hlzFHg%3d%3d 1/4 5/4/2021 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 12/16/2020 Date Validated 12/17/2020 Date Pending FBC Approval 12/26/2020 Date Approved 02/09/2021 Summary of Products FL# Model,Number or Name Description 25621.1 01: 26ga SnapMax on Plywood 26ga (min)SnapMax 1.0" nail strip on 15/32" (min) plywood or 3/4" (min)wood plank Limits of Use Installation Instructions Approved for use in HVHZ: No FL25621 R2 II 269a SnapMax plywood.pdf Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-97.25 Evaluation Reports Other: Refer to evaluation report FL25621 R2 AE 26ga SnapMax plywood.pdf Created by Independent Third Party: Yes 25621.2 02: 032 Aluminum SnapMax on Nominally 0.032"aluminum (or thicker)SnapMax 1.0" nail strip Plywood on 15/32" (min) plywood or 3/4"wood plank Limits of Use Installation Instructions Approved for use in HVHZ: No FL25621 R2 II 032 SnapMax plywood.pdf Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-78.5 Evaluation Reports Other: Refer to evaluation report FL25621 R2 AE 032 SnapMax plywood.pdf Created by Independent Third Party: Yes 25621.3 03: 032 Aluminum 12"SnapMax on Nominally 0.032"aluminum (or thicker)SnapMax 1.0" nail strip Plywood with 12"coverage on 15/32" (min)plywood or 3/4"wood plank Limits of Use Installation Instructions Approved for use in HVHZ: No FL25621 R2 II 032 SnapMax 12in Plywood.pdf Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-69.25 Evaluation Reports Other: Refer to evaluation report FL25621 R2 AE 032 SnapMax 12in Plywood.pdf Created by Independent Third Party: Yes 25621.4 04: 26ga SnapMax on Plywood 26ga (min)SnapMax 1.0" nail strip on 15/32" (min)plywood or 3/4" (min)wood plank Limits of Use Installation Instructions Approved for use in HVHZ: No FL25621 R2 II 26ga SnapMax plywood D.pdf Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-121.75 Evaluation Reports Other: Refer to evaluation report FL25621 R2 AE 26ga SnapMax plywood D.pdf Created by Independent Third Party: Yes 25621.5 05: 26ga SnapMax on Plywood HVHZ 26ga (min)SnapMax 1.0"nail strip on 15/32" (min)plywood or 3/4" (min)wood plank Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL25621 R2 II 26ga SnapMax plywood HVHZ.pdf Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-176 Evaluation Reports Other: Refer to evaluation report FL25621 R2 AE 26ga SnapMax plywood HVHZ.pdf Created by Independent Third Party: Yes 25621.6 06: 24ga SnapMax on Plywood 24ga (min)SnapMax 1.0" nail strip on 15/32" (min)plywood or 3/4" (min)wood plank Limits of Use Installation Instructions Approved for use in HVHZ: No FL25621 R2 II 24ga SnapMax plywood.pdf Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-206 Evaluation Reports Other: Refer to evaluation report FL25621 R2 AE 24ga SnapMax plywood.pdf Created by Independent Third Party: Yes 25621.7 07: 032 Aluminum SnapMax on Nominally 0.032"aluminum (or thicker)SnapMax 1.0" nail strip Plywood on 15/32" (min) plywood or 3/4"wood plank Limits of Use Installation Instructions Approved for use in HVHZ: No FL25621 R2 II 032 SnapMax plywood d.pdf https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckBl071JGil iolYgdSepo1 aWOZICDw56hlzFHg%3d%3d 2/4 5/4/2021 Florida Building Code Online Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-168.5 Evaluation Reports Other: Refer to evaluation report FL25621 R2 AE 032 SnapMax plywood d.pdf Created by Independent Third Party: Yes 25621.8 08: 032 Aluminum SnapMax on Nominally 0.032"aluminum (or thicker) SnapMax 1.0" nail strip Plywood HVHZ on 15/32" (min) plywood or 3/4"wood plank Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL25621 R2 II 032 SnapMax plywood HVHZ.pdf Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-175 Evaluation Reports Other: Refer to evaluation report FL25621 R2 AE 032 SnapMax plywood HVHZ.pdf Created by Independent Third Party: Yes 25621.9 09: 26ga 19"TopMax on Plywood 26ga (min)TopMax 1.5" nail strip with 19"coverage on 15/32" (min) plywood or 3/4" (min)wood plank Limits of Use Installation Instructions Approved for use in HVHZ: No FL25621 R2 II 26ga TopMax 19in plywood.pdf Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-63.5 Evaluation Reports Other: Refer to evaluation report FL25621 R2 AE 26ga TopMax 19in plywood.pdf Created by Independent Third Party: Yes 25621.10 10: 032 Aluminum TopMax on Nominally 0.032"aluminum (or thicker)TopMax 1.5"nail strip plywood HVHZ on 15/32" (min) plywood or 3/4"wood plank Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL25621 R2 II 032 TopMax plywood HVHZ.pdf Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-179.5 Evaluation Reports Other: Refer to evaluation report FL25621 R2 AE 032 TopMax plywood HVHZ.pdf Created by Independent Third Party: Yes 25621.11 11: 24ga TopMax on Plywood HVHZ 24ga (min)TopMax 1.5" nail strip on 15/32" (min) plywood or 3/4" (min)wood plank Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL25621 R2 II 24ga To plywood HVHZ.pdf Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-153.5 Evaluation Reports Other: Refer to evaluation report FL25621 R2 AE 24ga TopMax plywood HVHZ.pdf Created by Independent Third Party: Yes 25621.12 12: 24ga 19"TopMax on Plywood 24ga (min)TopMax 1.5" nail strip with 19"coverage on 15/32" HVHZ (min) plywood or 3/4" (min)wood plank Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL25621 R2 II 24ga TopMax 19in plywood HVHZ.pdf Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-116.25 Evaluation Reports Other: Refer to evaluation report FL25621 R2 AE 24ga TopMax 19in plywood HVHZ.pdf Created by Independent Third Party: Yes 25621.13 13: 032 Aluminum 19"TopMax on Nominally 0.032"aluminum (or thicker)TopMax 1.5"nail strip plywood HVHZ with 19"coverage on 15/32" (min)plywood or 3/4" (min)wood plank Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL25621 R2 II 032 TopMax 19in plywood HVHZ.pdf Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-166.75 Evaluation Reports Other: Refer to evaluation report FL25621 R2 AE 032 TopMax 19in plywood HVHZ.pdf Created by Independent Third Party: Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckBl071JGil iolYgdSepo1 aWOZICDw56hlzFHg%3d%3d 3/4 MAX FL25621 .06- R2 EXTREMEMETAL FABRICATORS SKILLED CRAFTERS OF METAL ROOFING SYSTEMS 24ga ( min ) SNAFMAX over 15/32"' ( min ) plywood Extreme Metal Fabricators 2160 SW Poma Dr I Palm City FL 34990 Product Description Nailstrip, snaplock style panel with a 16" maximum panel width and a nominal rib height of 1" Product Material 24ga (min) steel Corrosion resistant per FBC 1507.4.3 where required Fastener #10 x 1-inch pancake style fastener Compliant with FBC 1506.6 where required. Substrate/ Deck 15/32" (min) plywood or 3/4" (min) thick wood plank (min S.G. of 0.42) Evaluated by: David Eng, PE Timberlake Cove, LLC 3324 W Univ Ave #206 1 Gainesville FL FL PE 81377 1 FL CA 33344 www.TimberLakeCove.com \D EN sFF�G' Iry Digitally signed � by David E Eng_ No. 81377 =_✓� �Date: 2020.12.16 10:55:28+01'00'; �3 0 STATE OF IN SS •. � !ONAL • This item has been -. • and sealed by D.E. Eng, PE,on the copiesdate indicated. Printed SNAPMAX document are not considered signed copiesverified on any electronic MAX FL25621 . 06- R2 Underlayment: Comply with local building code or FBC 1507.1.1 where required. Slope: Comply with local building code or FBC 1507.4.2 where required. Re-Roofing: This panel may be installed over a single layer of existing shingles as permitted by local building code or FBC 1511, provided the existing roof meets the conditions required by the applicable code. Maximum Allowable Loads & Installation Requirements: ethod A: #10 x 1" fastener at 6" o.c. along nail strip: 206 PSF factor of safety of 2 has been applied. asteners are installed through the metal flange, NOT through the pre-punched slots Technical Documentation: This product has been tested to the UL 580 standard by Intertek Testing (TST-1527), report G3443.09-450-44, as referenced in FL 28059.01-RO. Compliance Statement: This product as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2 (non-HVHZ), as required by FL Rule 61G20-3, method 1D. This product as described has been tested and demonstrated compliance with: • UL580 - Test for Uplift Resistance of Roof Assemblies • UL 1897 - Uplift test for roof covering systems Design Process: The load tables in this report provides one prescriptive option for the fastening requirement for the applicable wind loads for roofs within the parameters described. For roofs outside of the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or other design code in force, using allowable stress. These load tables are based on ASCE 7-16. Use of these tables assumes that the structure is: • Enclosed and conforms to wind-borne debris provisions and is a regular shaped building • Is not subject to across-wind loading, vortex shedding, or instability; nor does it have a site location for which channeling or buffeting warrant consideration Engineering analysis may be completed by other licensed engineers for project specific approval by local authorities having jurisdiction. Certification of Independence: David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. The same entities do not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Exclusions and Limitations: Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated weathering/salt spray is outside the scope of this evaluation. This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions, interpretations, or designs made by others based on this evaluation report. This report is limited solely to documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding performance of this product. Installation shall be subject to the local building code and authority having jurisdiction; this report shall not be construed to supersede local codes in force. //04S646, EYTREMEMErALFABRICA TORS.COM MAX LOAD TABLES FL25621 . 06-R2 Instructions: Select the appropriate load table that applies to the structure in question. 2 2 Determine the design wind speed for the project a 3 location. 2 ;:2 Use the attachment method indicated for that 2windspeed within each roof zone. 2 3 11 2 3NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept. for each zone and reported using the standard zones For the load tables below, the worst case was taken 2 1 2 1-2-3: Zone 1 includes zones 1 and 1' 2 2 Zone 2 includes zones 2e, 2r, and 2n a� HIP ROOF GABLE ROOF �a Zone 3 includes zones 3e and 3r Combining these zones creates a clear, simple a_1°'OF LEAST HOIZONTAL DIMENSION OR 0 4h'WHICHEVER IS SMALLER'BUT NOT LESSTHANEITHER 4%OF LEAST HORIZONTAL DIMENSION DR 3FT(0.9M). scheme, at the expense of some design efficiency. OR AS DETERMINED BY DESIGN OR OTHER APPLICABLE CODE_ Contact the manufacturer for further information, ROOF ZONES FOR GENERIC BUILDING or consult a licensed design professional. 7METHODNR: NOT RATED FEMALE LEG SNAPS CONSULT DESIGN ONTO MALE LEGPROFESSIONAL AS NECESSARY STENER O.C. Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B,C,or D exposure area Have either a flat roof,or gable/hip roof with max slope of 12:12 Have either a flat roof,or gable/hip roof with max slope of 12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less FL25621.06: 24 a Sna Max on 15/32" Plywood FL25621.06: 24cia Sna Max on 15/32" Plywood Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A A A Zone 2: A A A A A A A A A A A Zone 2: A A A A A A A A A A A Zone 3: A A A A A A A A A A A Zone 3: A AA AAA AA A Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria.- Are located in Exposure B area Are located in B,C,or D exposure area Have either a flat roof less than 7°,hip roof with Have either a flat roof less than 7°,hip roof with max slope of 12:12,or gable roof with slope between 4.4:12&12:12 max slope of 12:12,or gable roof with slope between 4.4:12& 12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less FL25621.06: 24 a Sna Max on 15/32" Plywood FL25621.06: 24cia Sna Max on 15/32" Plywood Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A A A Zone 2: A A A A A A A A A A A Zone 2: A A A A A A A A A A A Zone 3: A A A A A A A A A A A Zone 3: A A A A A A A A A A TORS./o/as, EXTREMEMErALFABRICA •