HomeMy WebLinkAboutENGINEERING GENERAL NOTES: SCOPE OF WORK : PROJECT DESIGN DATA 7/22/2021 REVISIONS BY 1 .DEMO ALL UNPERMITED WORK PRERFORMED BY PREVIOUSE OWNERS JURISDICTION Saint lucie County THE BUILDER SHALL REVIEW DRAWINGS IN THEIR 2. NEW FRONT CMU BLOCK FACADE CODE FBC 2020 7th Edition, FBCR 2020 7th Edition 12-22-21 RAT ENTIRETY BEFORE STARTING WORK. THE BUILDER 3. NEW CMU BLOCK WALLS @ EACH END OF BUILDING CMU STRUCTURAL OPENING / O.H. GARAGE SHALL ACCEPT FULL RESPONSIBILITY FOR ANY 4. NEW 2HR RATED FIRE WALL DEVIDING SPACE IN TWO PROJECT NAME DOOR ERROR OR OMISSIONS NOT REPORTED IMMEDIATELY 5. RELOCATE ELECTRICAL SERVICE TO REAR OF BUILDING PROJECT ADDRESS 10535 S Ocean Dr Jensen Beach FL 34957 IN WRITING TO ENGINEER OF RECORD. BY SUBMITTING THESE PLANS FOR PERMIT THE BUILDER 6. INSTALL (2) NEW RESIDENTIAL ELECTRICAL RISERS & METER ACCEPTS FULL RESPONSIBILITY FOR THE ACCURACY 7. REMODEL EXISTING RESTROOM DIRECT REPLACMENT OF FIXTURES ONLY ARCHITECT/ENGINEER OF THE INFORMATION DEPICTED WITHIN AND IT IS 8. INSTALL NEW RESTROOM NORTH SIDE OF BUILDING ASSUMED THE BUILDER HAS READ AND 9. DECOMISSION (2) IN FLOOR GREASE TRAPS UNDERSTANDS THE NOTES BELOW. 10. PERMIT COMMERCIAL REMODEL (2) UNITS RISK CATEGORY II ASSUMED SOIL BEARING CAPACITY: 2500 PSF WIND SPEED ASCE 7-16 (3 Sec Gust) 165 MPH STRUCTURAL DRAWINGS SHALL BE USED IN AS 135 MPH CONJUNCTION WITH JOB SPECIFICATIONS AND EXPOSURE D ARCHITECTURAL, MECHANICAL, ELECTRICAL, MEAN BUILDING HEIGHT' <15'-0" PLUMBING, AND SITE DRAWINGS ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO ANY SIMILAR SITUATIONrD ELSEWHERE ON THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. IsbFid ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN FIELD. DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. IF ANY DISCREPANCIES ARE z DISCOVER THE ENGINEER OF RECORD MUST BE .��� CONTACTED BEFORE THE COMMENCEMENT OF CONSTRUCTION. ti THE STRUCTURE IS DESIGNED TO SELF SUPPORTING AND STABLE AFTER BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES TO INSURE _ SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, ---- TEMPORARY BRACING, GUYS OR TIE DOWNS. THE STRUCTURAL LAYOUT SHOWN IS SCHEMATIC IN LLI - co NATURE. HOWEVER, THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE O SCHEME SHOWN WILL CLOSELY PARALLEL FINAL p LAYOUT. PROPOSED NEW FACADE C SCALE: 1 /g„ - 1 ,_0„ A/R.N/A IY• w SS J0 m C) V C N TY MAP o CS SCALE: NTS A/R: w 75 U 10535 OCEAN ° O LO 00 TABLE R301.2(2)-continued U C:) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B(ASD) (psf)a,b,c. d,e,f EFFECTIVE ULTIMATE WIND AREA DESIGN WIND (w) SPEED,V L, 5 l h ZONE (mph) 160 PROPOSED FRONT ELEV (53 6 4 FOS Neg o 2 LL 4 4 1,2e 10 20.6 -39.3 Ul 0 CS SCALE: 1 /8" - V-0" A/R.N/A �a 0 1,2e 20 17.8 39.3 Z w f 1,2e 50 14.0 -33.5 (1 U z Z Q 1 G I 1,2e 100 11.2 28.8 - r 2n,2r,3e 10 20.6 -62.8 w W N LO , 2n,2r,3e 20 17.8 -55.0 Q W ❑ ID Al0 2n,2r,3e 50 14.0 44.7 Z (n Z❑ Z N 2n,2r,3e 100 11.2 -37.0 ❑ W p U 3r 10 20.6 -74.5 U Z ❑ Q L3 ^ HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE 00 3r 20 17.8 -62.8 � Q Q E lV MEAN ROOF HEIGHT EXPOSURE CATEGORY m 3r 50 14.0 -46.4 Q Q U [� a Walls (ft) B cc 3r 100 11.2 -46.4 [] L 15 0.82 4 10 27.6 -30.0 Q 3 4 20 26.4 -28.7 3 ❑ 4 50 24.8 -27.1 L For SI: 1 foot = 304.8 mm, 1 degree = 0.0175 rad. 4 100 23.5 -25.8 Note: a = 4 feet in all cases. N 4 500 20.6 22.9 3: 5 10 27.6 -37.0 FIGURE R301 .2(7) 5 20 2 .4 -34.5 5 50 24.8 -31.2 COMPONENT AND CLADDING PRESSURE ZONES 5 100 23.5 -28.7 5 500 20.6 -22.9 U] W U > 90 /� W co %•� 1 w U] A � 2 z 0 PRESSURE ZONES � LL GPQ Q CS SCALE: NTS A/R:N/A o DATE 12-21-21 SCALE Digitally signed by Paul DRAWN 12-21-21 3 ROOF PLAN Welch JOB 10535 CS SCALE: 4 1 " = V-0" AN R: A au Welch / / / Date. 2022.01 .1811 .03.00 SHEET -05'00' CS THIS ELECTRONIC SIGNATURE, ALONG WITH P.E. SEAL ON EACH SHEET CERTIFIES ALL SHEETS IN THIS FILE OF SHEETS REVISIONS BY 12-22-21 RAT 66'-711 DEMO UNPERMITED DEMO UNPERMITED WOOD STRUCTURAL WALLS WOOD STRUCTURAL WALLS co m L zILL ^ m OU) DEMO OLD w FIRE WALLS 0 IN ATTIC BUILD TEMP PROTECTION BUILD TEMP PROTECTION O BARRIERS DEMO OLD DEMO OLD BARRIERS U) CD FIRE WALLS FIRE WALLS co IN ATTIC IN ATTIC O O C15 m 0 o DEMOLITION NOTES J T T 1. DUE TO THE NATURE OF THIS PROJECT AND THE STATE OF THE EXISTING BUILDING, U7 � 0 Ill Ln co M IT IS IMPOSSIBLE TO COMPLETELY RELATE THE SCOPE OF THE DEMOLITION U z Z Q �UJ COMPLETED IN THE PAST. w a w L9 r co DEMO (2) LAYERS OF 2. INFORMATION REGARDING THE EXISTING CONDITIONS WAS GATHERED FROM THE p W u] C) 0 00 GYP BOARD FROM In ALL AVAILABLE EXISTING DRAWINGS, SURVEY AND CORRESPONDENCE WITH UTILITY, z C7 z 0 `� C3 ALL CEILINGS DIG TO DISCOVER FOOTING STAFF AND MUNICIPAL PERSONNEL. THERE ARE NO GUARANTEES AS TO THE 0 Z Ll Ll w CONDITION Ll — Ll & INSULATION ACCURACY OF THIS INFORMATION AND IT IS OFFERED FOR INFORMATION ONLY. � Q Q a N DEMO ALL ROOF TOP O L Ll BACK SLAB AND UNDER EQUIPMENT AND REPAIR CUT BACK SLAB , UNDER PIN 3. MINIMIZE DISTURBANCE AND/OR DAMAGE TO EXISTING FINISHED SURFACES AND Q 0 U 0-- CUT PIN & POUR NEW FOOTINGS ROOF & POUR NEW FOOTINGS FOR FINISHES. ALL FIRE AND SMOKE RATINGS SHALL BE RETAINED AS PART OF THE U D o FOR NEW CMU WALLS NEW CMU WALLS REPAIRS AND PATCH/SEAL HOLES WEATHERTIGHT WHERE REQUIRED. LL o 4. ALL AREAS OF EGRESS SHALL BE KEPT OPEN AND FREE FROM DEBRIS AT ALL TIMES. 1 5. DO NOT REMOVE ITEMS SUPPORTING OTHER ITEMS WITHOUT PROVIDING � TEMPORARY OR PERMANENT SUPPORT AS REQUIRED. SEE DRAWINGS FOR AREAS DECOMMISION GREASE AND EXTENT OF ASSUMED DEMOLITION. PROPERLY SUPPORT ALL EXISTING ITEMS TO co BUILD TEMP SHURING WALLS TRAPS BUILD TEMP SHURING WALLS REMAIN. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING REQUIRED SUPPORTS w TO JACK ROOF TRUSSES g�_4�8 TO JACK ROOF TRUSSES FOR AFFECTED ITEMS. h �'oJ o 6. PURPOSE OF THIS DEMOLITION IS TO DETERMIN THE REQUIERED ENGINEERING TO co w BRING THIS LOCATION UP TO FBC2020 7TH ED. co 02 z LL Q Q DEMO UNPERMITED DEMO UNPERMITED DATE 07-22-21 WOOD STRUCTURAL WALLS WOOD STRUCTURAL WALLS SCALE DRAWN 07-22-21 DEMO PLAN JOB 10535 D1 SCALE: 1 /4" = V-0" A/R:N/A REMOVE DOOR AND INFILL SHEET PER SHEET 002 Dl OF SHEETS BRUSH REVISIONS BY CONCRETE SURFACE 12-22-21 RAT X N a � � S D D D a CONCRETE � D a D DRILL 1 /8" LARGER HOLE THAN ALL THREAD ROD OR REBAR. CLEAN OUT WITH BLOWOUT BULB. COMPLETE HOLE PREPARATION WITH USE OF A 8"X ' CONCRETE ) NYLON BRUSH (DO NOT USE WIRE BRUSH) COLUMN (HIGH (1 ) VERT# REBARS PSI MIN.) INTO EXISTING HEADER EPDXYTUBE CONCRETE SURFACE 12" #5 BAR @16" O.C. EPDXY IN U" OR r- OUR IN TILLED CELL a 12" 5 BAR @16" D.C. D EPDXY IN 6 ' OR POUR D IN FILLED C LL � EPDXY a CONCRETE � D D 8"X8' CONCRETE PRIOR TO INJECTION, DISCHARGE ONE FLUID OUNC LO OF EPDXY OR UNTIL UNIFORM IN COLOR. FILL THE STRENGTH GROUT 4000 HOLE TO 1 /2 THE HOLE DEPTH. z M PSI MIN.) z O EMBEDDED BOLT LU O LOL CONCRETE SURFACE OR REBAR a O w CD O co J aa)i LAP BARS MIN 25 Q Q cn o a � (D EXISTING FOOTING = o 0 6" MIN. a D v o 48 48 48 (1 ) VERT #5 REBARS EPDXY DOWLED >� O 8" INTO EXISTING FOOTING MAX 4' �/ > 0 0.C. a CONCRETE V L0 V (y)L0U) 0 CM U WALE INFILL INSERT ALLTHREAD ROD OR REBAR SLOWLY BY 002 SCALE: 1 " = 1 '-0" A/R:N/A #3@16" o.c STAGGERED AT HAND INTO THE HOLE TO THE END USING A SLOWTWISTING MOTION. HARDENING WILL BEGIN IN 7 EACH SIDE, INSTALLED IN 4" MINUTES AT ROOM TEMPERATURE. IMPORTANT DO DEEP HOLES DRILLED INTO 2'-0" MIN. EXISTING CONCRETE Stucco Installation, Procedures and Guidelines EXISTING SLAB USING SLAB ON FILL NOT LOAD FOR 3 DAYS. Masonry: EPDXY/ ADHESIVE. TYP. 1 '-0" 2 2 4 Conventional stucco over masonry surfaces may be applied with two or three coats. Two-coat systems OVERLAP N EPDXY U over masonry consist of: first coat = 3/8 inch thick and finish coat = 1/8 inch thick; or over cast concrete z Q � consist of: first coat = 1/4 inch thick and finish coat = 1/8 inch thick. Three-coat systems consist of: rn L9 :1 first coat — 1/4 inch thick, III=1'-1=1'-1=1'-1=1'-1=' — —1'1=III=1'-1=1'-1=1'1=1'—I INSTALLATION W W W W W second coat = 1/4 inch thick, and finish coat = 1/8 inch thick over both III— —III W NEW #3 HORIZONTAL III SAND, GRAVEL OR u] p 0 masonry and cast concrete. CONTINUOUS. INSTALL III— I C II o LIME ROCK FILL WELL Z D z It When required by ASTM C 926, Section 5.2.2; an exterior bonding agent, conforming to ASTM C 932, #3Q12" o.c. IF WIDTH F IIIIII I = I I III COMPACTED. PROCEDURES 0 Z U U W 11=1 11=1 11=1 I =1 =1 I I III v _ o W _ shall be used on all masonry surfaces. In lieu of a bonding agent, a dash coat, roughing the surface, or SLAB-CUT EXCEEDS 24 DO NOT UNDERMINE EXISTING SLAB Q Q ro metal lath are also acceptable methods for bonding. NEW / L` W W w 6 MILL VAPOR PLUMBING Q Q @ a , FBC 2510.3 Installation, references ASTM C 926 requires form ties or other obstructions (including PIPE MAINTAIN 6 OVER LAP WITH U r 3 q g BARRIER BELOW EXISTING VAPOR BARRIER 3 V masonry cut nails for clean out opening forms) to be removed or trimmed back even with the surface of SLAB 3 o the solid base. In addition, if the nails are to be trimmed flush and left in place, they need to be corrosion SLAB-CUT REPAIR DETAIL `` resistant as would be required for lath or other metal accessories, ASTM C 926 section 5.2 and C 1063 section 6. FBC B302.8 REPAIRS. WHERE PORTIONS OF AN EXISTING SLAB HAVE BEEN REMOVED AND ARE ABOUT TO BE REPLACED, A MEMBRANE SHALL BE CAREFULLY FINED TO THE OPENING AND ALL OPENINGS BETWEEN THE MEMBRANE AND THE SOIL CLOSED WITH TAPE OR MASTIC. w TABLE 1405.2 MINIMUM THICKNESS OF WEATHER COVERINGS ^y �oJ U COVERING TYPE MINIMUM THICKNESS 1 . CONCRETE COMPRESSIVE STRENGTH F c= 3000 PSI. � W 2. REINFORCING: TO BE DEFORMED BARS CONFORMING ASTM A615, GRADE 60. 1 .�.7 a LO W (inches) 3. CLEAN AND ROUGHEN THE CONTACT SURFACES AT EACH SIDE OF SLAB CUT °� Stucco or exterior cement plaster Three-coat work over: AND PROVIDE BONDING AGENT PRIOR TO POURING. ��� Goz 4. D . DEPTH OF TRENCH AS NEEDED TO ACHIEVE REQUIRED PIPER SLOPE. q W Unit masonry 0.625b �P 0 TERMITE PROTECTION DATE 07-22-21 Two-coat work over: 0.5b PROVIDE SOIL TREATMENT PROTECTION AGAINST SUBTERRANEAN TERMITES FOR ALL Unit masonry SLAB CUTS IN COMPLIANCE W/ FBC SECTION 1816. A CERTIFICATE OF COMPLIANCE SCALE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED b. Exclusive of texture. TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS DRAWN 07-22-21 ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." JOB 10535 2 SLAB REPAIR DETAI SHEET 002 002 SCALE: NTS A/R:N/A OF SHEETS