HomeMy WebLinkAboutEngineer LetterSoutheast Building Engineers, LLC 3578 Rolling Acres Road Pace, FL 32571 RECEIVED 772-774-9086 s.sanders@sebenin�eQxs.c�o a JAN 2 6 2022 St., County Permitting January 24, 2022 RE: Application of %11 CDX Over Ix Tongue and Groove Roof Decking Austin Residence — Permit Number 2112-0732 109 W Alden St Port St. Lucie, FL To Whom It May Concern: � 1�This letter is to certify that it is acceptable to apply '/2" CDX plywood sheathing over the existing x tongue and groove roof deckin at the above referenced property in preparation for the installation of a new roof covering. The '/2" CDX plywood shall be attached using 12d ring shank nails installed at 4" on cen covering). the field and on the edges. The roofing contractor shall ensure that the 12d fasteners are installed through the existing lx tongue and groove roof decking and into the underlying roof framing. ®( Should you require any additional information or clarification, please contact me. Sincerely, CflX p �► IG 1-ZS ' Z o z2 FL Reg. No. 64781 I - 2T -0,02ZZ p.EVIEWED FOR COMPLIANCE yIE �; UNTY EOCC pe�vec- I I Z- z. Page 1 I 1 Southeast Building Engineers, LLC 3578 Rolling Acres Road Pace, FL 32571 772-774-9o86 s.sanders@s en9111eers.com January 24, 2022 REVIr City of Port St. Lucie Building Department cOoi VVQ F0� 121 SW Port St. Lucie Blvd. LCcMP�I Port St. Lucie, FL 34984 �DE �°�E ccM�r 14�cL� Subiect: %1' CDX Sheathing Overlay Inspection for Code Red Roofing�eccc Metcalf Residence — Permit Number 2112-0732 109 W Alden St Port St. Lucie FL. To Whom It May Concern: This firm was retained to certify the installation of the %" CDX roof sheathing over the existing structural roof decking for the above referenced project. Our findings are as follows: Background: The contractor, Code Red Roofers, overlaid the existing tongue and groove lx8 structural roof decking with %2" CDX . The contractor showed proof of having attached the %2" CDX sheathing with 12d ring shank nails spaced at 4 inches on center in the field and edges through the existing lx8 decking into the underlying wood roof trusses. Inspection Description: Views of/z" CDX sheathing being installed over the tongue and groove lx8 decking. Page 112 Southeast Building Engineers, LLC 3578 Rolling Acres Road Pace, FL 32571 772-774-9o86 s.sanders a�,Sebelagineers.coM REVIEWED FOR CODE COMPLIANCE T. LUCIE COUNTY BOCC Views of nail patter and nails in the installed''/2" CDX sheathing. The contractor provided photographs of the work area sufficient to verify the installation of the 1/2" CDX sheathing and the mechanical fastener attachment. Findings: We hereby certify that the %2" CDX roof sheathing was installed in a satisfactory manner to comply with the project specifications and the 2020 Florida Building Code, 701 Edition.. Should you require any additional information or clarification, please contact me. Sincerely, Southeast Building Engineers, LLC Page 212