Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutPRODUCT APPROVAL - ROOFING UNDERLAYMENTS , 1 �
11/« /21.2:13 PM Florida Building Code Online
Business ` ® ® RECEIVED p
Nub
n K..,. ,..
BCIS Home Log In I User Registration I Hot Topi"' Submit^SurE �� Statr&FacLs I Publications Contact Us .� BCIS Site Map Links •Search .�
F�Oflda St.Lucie County
C ;;i "' �Product Approval Permitting
- I
FJ USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL2569=R23
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived �
e
!/IEVv ;.;D""'�, .x
Product Manufacturer Soprema,Inc.(Canada) FI s ODE C - j, "
0
Address/Phone/Email 1640 rue Haggarty '^' � �� .r ,
Drummondville, NON-US 008 "
(819)478-2400
memathleu@soprema.ca 0@@r� '"
Authorized Signature Marc-Etienne Mathieu
memathleu@soprema.ca
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville, NON-US 00000
(819)478-2400 Ext 3327
memathleu@soprema.ca
Quality Assurance Representative Jean-Francois Cote, Ph.D. LE GO
Address/Phone/Email 1640 rue Haggarty
Drummondville'
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated By John W. Knezevich, PE
( Validation Checklist-Hardcopy Received
Certificate of Independence FL2569 R23 COI 2021 01 COI NIEMINEN.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D4601 2012
ASTM D4798 2011
FM 4474 2011
FRSA/TRI Sixth Edition 2018
TAS 103 2020
UL1897 2015
hftps://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgsKQFEnckBI08ErxlUd3xYldTUyLi2pFprvGZEoRjE%2fHg%3d%3d 1/2
11/23/21,2:13 PM Florida Building Code Online !7
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 07/29/2021
Date Validated 08/03/2021
Date Pending FBC Approval 08/09/2021
Date Approved 10/12/2021
Summary of Products
FL# Model,Number or Name Description
2569.1 Soprema Roof Underlayments for Self adhering roof underlayments
use in FBC HVHZ jurisdictions
Limits of Use Installation Instructions .
Approved for use in HVHZ:Yes FL2569 R23 II 2021 07 29 FINAL ER SOPREMA HVHZ FL2569-
Approved for use outside HVHZ:No B21,P-9
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party:Yes
Other: Refer to ER Section 5 for Limits of Use. Evaluation Reports
FL2569 R23 AE 2021 07 29 FINAL ER SOPREMA HVHZ FL2569-
R2.pdf
Created by Independent Third Party:Yes
2569`2 Soprirr ROof�Underlayments for Self adhering,,roof underlayments
UM in FBC non-HVH Urisdictions
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL2569 R23 II 2021 07 29 FINAL ER SOPREMA NON-
Approved for use outside HVHZ:Yes HVHZ F1,2569-1123.12d
Impact Resistant: N/A Verified By: Robert Nieminen,P.E. PE-59166
Design Pressure: +N/A/-150 Created by Independent Third Party:Yes
Other: 1.)Refer to ER Section 5 for Limits of Use.2.) Evaluation Reports
The design pressure noted herein pertains to FL2569 R23 AE 2021 07 29 FINAL ER SOPREMA NON-
underlayment systems used beneath tile roof systems. HVHZ FL2569-R23.pdd
Refer to ER Section 5.8.3 for details. Created by Independent Third Party:Yes
Back Next
Contact us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Cop ririnlit 2007-2013 State of Florida.::Privaa Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity,Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
eChrck
Credit Card
Safe
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGE\/XQwtDgsKQFEnckB108Erx1 Ud3xYIdTUyLi2pFprvGZEoRjE%2fHg%3d%3d 2/2
NEMO I etc.
Certificate of Authorization#32455
353 Christian Street, Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION REPORT
Soprema, Inc. Evaluation Report S18010.06.09-R21
1640 rue Haggerty FL2569-R23(NON-HVHZ)
Drummondville,Quebec 32C 5P8 Canada Date of Issuance:06/15/2009
(819)478-2400 Revision 21:07/29/2021
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7" Edition(2020)Florida Building Code sections noted herein.
DESCRIPTION: Soprema Roof Underlayments for use in FBC non-HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE:This.Evaluation Report is valid until such time asthe named product(s)changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s)change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify MEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by: --
/ `.a-ors -. -_''� :.2~••�'1,5?e�e�afi .Y
Robert J.M. Nieminen,P.E. •.D� �,.`e The facsimile seal appearing was authorized by Robert
Florida Registration No.59166 Florida DG4 ANE1983 s .•-j+E: •' Nieminen,P.E.on 07/29/2021.This does not serve as
;
' s: .... an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEW ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2019 NEMO ETC,LLC
NNEMO etc.
ROOFING COMPONENT EVALUATION:
1. -SCOPE.
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Soprema Roof Underlayments,as produced by Soprema,have demonstrated compliance
with the following sections of the 7eh Edition(2020) Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use
set forth herein.
STANDARDS.IL
Section Property Standard Year
1504.3.1 Wind resistance FM 4474 2011
1504.3.1 Wind resistance UL 1897 2015
1507.1.1,1507.2.4,1507.2.9.2 Material standard ASTM D1970 2015
/R905.1.1,R905.2.8.2
1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) FRSA/TRI 04-12(MS) 543530.02.14-1-R1 02/21/2014
ERD(TST6049) ASTM D1970(QC) S44870.04.14-3 04/02/2014
ERD(TST6049) ASTM D1970(OH) S44870.04.14-1 04/10/2014
ERD(TST6049) ASTM D1970(MS) S44870.04.14-4 04/10/2014
ERD(TST6049) ASTM D1970(OH) S40540.10.14 10/31/2014
ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-RI 06/07/2017
NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-R1 04/25/2018
NEMO(TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018
NEMO(TST6049) Tile Slippage 4S-SOPC-18-002.09.18 09/21/2018
NEMO(TST6049). ASTM D4798/D1970(OH&MS) 4S-SOPC-18-002.05.19.A 05/31/2019
NEMO(TST6049) Tensile Adhesion/Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-20-SSUDL-01.A 01/07/2021
NEMO(TST6049) ASTM D1970(MS) 4j-SOPC-2I-SSUDL-01.A 04/19/2021
PRI(TST5878) ASTM D1970(MS) SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
NEMO Traceability FBC Cross-Listing 07/28/2021
UL,LLC(QUA9625) Quality Control MLA File No.R16814 12/10/2015
UL,LLC(QUA9625) Quality Control MLA File No.R27605 05/08/2019
UL,LLC(QUA9625) Quality Control Service Confirmation 06/29/2020
UL,LLC(QUA9625) Quality Control Florida BCIS Current
NEMO ETC,LLC Evaluation Report 518010.06.09-1121
Certificate ofAuthorizotion#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R23(NON-HVHZ)
Soprema Roof Underlayments Revision 21:07/29/2021
Page 2 of 8
z '
NNEMOjetc.
PRODucT DESCRIPTION
Material
Product Standard Plant(s) Description, ,
4.1 LASTOBOND TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric
FRSA/TRI 09-18 surfaced,SBS modified bitumen roof
underlayment
4.2 SRS TopShield DEFENDER ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric
TU FRSA/TRI 09-18 surfaced,SBS modified bitumen roof
underlayment
4.3 Tri-Built S/A HT TU ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric
Underlayment FRSA%TRI 09-18 surfaced,SBS modified bitumen roof
underlayment
4.4 LASTOBOND Shield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.5 RESISTO SA SMOOTH PLY ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
40 modified bitumen roof underlayment
4.6 LASTOBOND Shield HT ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.7 LASTOBOND Pro HT-N ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4 8 €L9 TO`TCYN Pro HT�jS (�STM'D1970) Drummon_vl e C1C se f a�henng,:woven?per)ethy,ene�su aced }iigF�i
temperature;SB: ,S modiie_-Etumen°roof)
under ayment
4.9 EnviroShield ASTM D1970 Drummondville,QC. self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.10 LASTOBOND Eco ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.11 LASTOBOND Smooth ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Seal HT Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment'
4.12 Tri-Built Smooth HT S/A ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Underlayment Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.13 PrimeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Smooth Seal HT Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.14 RESISTO LB1236 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.15 TRI-BUILT Sand-R SA ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Shingle Underlayment Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.16 PrimeSource Grip-Rite ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Eave&Valley Protector Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
NEMO ETC,LLC Evaluation Report S18010.06.09-R21
Certificate ofAuthorizotion#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R23(NON-HVHZ)
Soprema Roof Underlayments Revision 21:07/29/2021
Page 3 of 8
NNEMOletc.
Product Material Plant(s) Description
Standard
4.17 SRS TopShield ICE& ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
WATER DEFENDER Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.18 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FBCSection: 1507.2 1507.3 1507.4&1507.5 1507.7 1507.8&2507.9
Asphalt
Clay and Concrete Tile Metal Slate or
Wood Shakes or
Underlayment Mechanical Adhesive- Slate-Type Shingles
Shingles Attach Set Panels Shingles Shingles g
LASTOBOND TU HT,SRS TopShield Yes
DEFENDER TU,Tri-Built S/A HT TU Yes Yes Yes Yes Yes Yes (joint strips,1507.1.1.3/
Underlayment See 5.6.1 R905.1.1.3)
LASTOBOND Shield,Pro HT-N,RESISTO Yes
SA SMOOTH PLY 40 Yes No No Yes Yes Yes (joint strips,1507.1.1.3/
R905.1.1.3)
es
(LAST_OBOND Shield NT,-ProHT=S Yes No No es Yes es o!Et apt 5 07:1:13Ti
RJ05"13:3
Yes
EnviroShield Yes No No Yes Yes Yes (joint strips,1507.1.1.3/
R905.1.1.3)
LASTOBOND ECO,RESISTO LB1236,TRI-
BUILT Sand-R SA Shingle Underlayment, Yes
Grip-Rite Eave&Valley Protector, Yes No No No No Yes (joint strips,1507.1.1.3/
TopShield ICE&WATER DEFENDER, R905.1.1.3)
RESISTO LB1244
LASTOBOND Smooth Seal HT,Tri-Built Yes
Smooth HTS/A Underlayment,Grip-Rite Yes No No Yes Yes Yes (joint strips,1507.1.1.3/
Smooth Seal HT R905.1.1.3)
NEMO ETC,LLC Evaluation Report S18010.06.09-R21
Certificote ofAuthorizotion#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-1123(NON-HVHZ)
Soprema Roof Underlayments Revision 21:07/29/2021
Page 4 of 8
ONEMOletc.
5.6.1 Adhesive-set tile is limited to use of the following Approved underlayment/tile-adhesive combinations.
TABLE 1A:ALLOWABLE TILE ADHESIVE UNDERLAYMENT COMBINATIONS'
Underlayment Adhesive - Florida Product Approval
LASTOBOND TU HT,SRS Dupont"Tile Bond'"Roof Tile Adhesive" FL22525
TopShield DEFENDER TU,Tri-
Built S/A HTTU Underlayment ICP Adhesives and Sealants"Polyset®AH-160" FL6332
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates(designed to meet wind loads for project)
Underlayment Application
Type Primer Material(s)
LASTOBOND Shield,LASTOBOND Pro HT- (Optional)ASTM
N,RESISTO SA SMOOTH PLY 40, Deck/ D41,Elastocol Stick, Plywood,OSB or Southern Yellow
Pine(SYP)
LASTOBOND Shield HT,LASTOBOND Pro
sheathing Elastocol Stick Zero
HT-S,EnviroShield,LASTOBOND TU HT, ASTM D41 structural concrete
SRS TopShield DEFENDER TU,Tri-Built
S/A HTTU Underlayment,LASTOBOND Insulation (Optional)Elastocol Dens Deck Prime or SECUROCK
ECO,RESISTO LB1236,TRI-BUILT Sand-R self Stick Zero Gypsum-Fiber Roof Board
SA Shingle Underlayment,Grip-Rite Eave adhering
&Valley Protector,TopShield ICE&
WATER DEFENDER,RESISTO LB1244, Base Sheet (Optional)Elastocol ASTM D226,Type II felt or
LASTOBOND Smooth Seal HT,Tri-Built Stick Zero Modified Sopra-G
Smooth HT S/A Underlayment or Grip-
Rite Smooth Seal HT
LASTOBOND TU HT,SRS TopShield
DEFENDER TU,Tri-Built S/A HT TU
Underlayment,RESISTO LB1236,TRI- self- Existing RESISTO EXTERIOR Existing sand-surfaced,glass-fiber
BUILT Sand-RSA Shingle Underlayment; adhering substrate PRIMER surfaced,mineral-surfaced or film-
Grip-Rite Eave&Valley Protector or surfaced roof underlayment*
TopShield ICE&WATER DEFENDER
*Final acceptance of any existing substrate in a reroof(tear-off)installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive LASTOBOND TU HT,SRS TopShield
DEFENDER TU,Tri-Built S/A HTTU Underlayment RESISTO LB1236,TRI-BUILT Sand-RSA Shingle Underlayment,Grip-Rite Eave& Valley
Protector or TopShield ICE&WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the
self-adhering underlayment
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions,but—for mechanically attached base sheets-not less than Section 5.8.3 herein.
i Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report S18010.06.09-1121
Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-1123(NON-HVHZ)
Soprema Roof Underlayments Revision 21:07/29/2021
Page 5 of 8
NMEMO I etc.
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety'per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Table 1A or the critical(highest)
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-45.0 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)Elastocol Stick,Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: LASTOBOND TU HT,SRS TopShield DEFENDER TU,Tri-Built S/A HT TU'Underlayment,self-adhered and
back-nailed within the selvedge-edge side laps using 12 ga.x 1Y<"ring shank nails through 32 ga.,1-5/8"
diameter tin caps spaced 12-inch o.c..
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: LASTOBOND TU HT,SRS TopShield DEFENDER TU,Tri-Built S/A HT TU Underlayment,self-adhered and
back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"
diameter tin caps spaced 12-inch o.c..
#3 Maximum Design Pressure=-120.0 psf:
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40,self-adhered.
Underlayment: LASTOBOND TU HT,SRS TopShield DEFENDER TU,Tri-Built S/A HT TU Underlayment,self-adhered and
back-nailed within the selvedge-edge side laps using 12 ga.x 1'/0"ring shank nails through 32 ga.,1-5/8"
diameter tin caps spaced 12-inch o.c..
#4 Maximum Design Pressure=-150.0 psf:
Deck: Min.15/32-inch APA-rated BCX plywood(may be installed C-side up)to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: LASTOBOND TU HT,SRS TopShield DEFENDER TU,'Tri-Built S/A HT TU Underlayment,self-adhered and
back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"
diameter tin caps spaced 12-inch o.c..
#5 All other direct-deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of-45 psf.
5.8.3.2 Mechanically-Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Table 1A or the critical(highest)
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
PRIME design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated
pressure zones shall employ an attachment density by a qualified design professional to resist the elevated
pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing
Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*
carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
NEMO ETC,LLC Evaluation Report S18010.06.09-1121
Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION F1.2569-1123(NON-HVHZ)
Soprema Roof Underlayments Revision 21:07/29/2021
Page 6 of 8
NNEMO I etc.
#6 Maximum Design Pressure=-60.0 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC 1517.5.2)spaced 6-
inch o.c.at the 4-inch laps and 6-inch o.c.in three(3),equally spaced rows in the center of the sheet.
Underlayment: LASTOBOND TU HT,SRS TopShield DEFENDER TU,Tri-Built S/A HT TU Underlayment,self-adhered and
back-nailed within the selvedge-edge side laps using 12 ga.x 1X"ring shank nails through 32 ga.,1-5/8"
diameter tin caps spaced 12-inch o.c.
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment
attachment shall be in accordance with the manufacturer's installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment Prepared Roof Cover Maximum
Installation Type Exposure(days)
LASTOBOND Eco,RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,
Grip-Rite Eave&Valley Protector,TopShield ICE&WATER DEFENDER or RESISTO Mechanically attached 30
LB1244
LASTOBOND Shield,LASTOBOND Pro HT-N,RESISTO SA SMOOTH PLY 40,
LASTOBOND Shield HT,LASTOBOND Pro HT-S,EnviroShield,LASTOBOND Smooth Mechanically attached 90
Seal HT,Tri-Built Smooth HT S/A Underlayment or Grip-Rite Smooth Seal HT
LASTOBOND TU HT,SRS TopShield DEFENDER TU or Tri-Built S/A HT TU Mechanically attached or
Underlayment adhesive-set tile roof 180
system
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Slope
Flat Max.10-tile stack 6:12
Lugged Max.10-tile stack 5:12
Double-tile stacking method,as shown below 6:12
LASTOBOND TU HT,
SRS TopShield
DEFENDER TU,Tri-Built
S/A HT TU Lugged
Underlayment
NEMO ETC,LLC Evaluation Report S18010.06.09-R21
Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R23(NON-HVHZ)
Soprema Roof Underlayments Revision 21:07/29/2021
Page 7 of 8
NNEMO I etc.
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.2.1 Installation of RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave&Valley Protector or
TopShield ICE&WATER DEFENDER self-adhering underlayment in a reroof(tear-off) application atop an existing
underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate in a reroof(tear-off) installation is at the discretion of the installer and the
Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive
RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave&Valley Protector or TopShield ICE
&WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
6.3 LASTOBOND TU HT, SIRS TopShield DEFENDER TU, Tri-Built S/A HT TU Underlayment, LASTOBOND Shield,
LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S,
EnviroShield,LASTOBOND Eco,LASTOBOND Smooth Seal HT,Tri-Built Smooth HT S/A Underlayment,Grip-Rite
Smooth Seal HT, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave & Valley
Protector,TopShield ICE&WATER DEFENDER or RESISTO LB1244:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type II felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.3.2 Tile Applications:
Limited to LASTOBOND TU HT,SRS TopShield DEFENDER TU or Tri-Built S/A HT TU Underlayment.
Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
•
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
MANUFACTU,RiN;s PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
QUALITY
UL, LLC—QUA9625;(314)578-3406; k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report 518010.06.09-1121
Certificate ofAuthorizotion#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R23(NON-HVHZ)
Soprema Roof Underlayments Revision 21:07/29/2021