Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ASPHALT SHINGLES 2/17/2021 Florida Building Code Online FLOPIOA OVARTMENT OF Li iYl ait ProfessionalBusiness & Regulation r BCIS Home I Log In I User Registration Hot Topics Submit Surcharge stats&Facts Publications Contact Us BCIS Site Map Links Search bpr Product Approval` USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail OFFICE OF THE FL# FL35321 SFCRETARY Application Type New Code Version 2020 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer TAMKO Building Products LLC Address/Phone/Email PO Box 97 Galena, KS 66739 (417) 624-6644 Ext2305 kerri_eden@tamko.com Authorized Signature Kerri Eden kerri_eden@tamko.com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin, MO 64802 (417) 624-6644 Ext2305 kerri_eden@tamko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity UL LLC Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 11/18/2021 Validated By Robert Nieminen, PE, NEMO ETC, LLC Validation Checklist- Hardcopy Received Certificate of Independence FL35321 RO COI UL Standards of Business Conduct-Independence.pdf Referenced Standard and Year(of Standard) Equivalence of Product Standards Certified By Sections from the Code 104.11 1504.6 1507.2.5 1507.2.7.1 R905.2.4 R905.2.6.1 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqugTpvOGuj4wUr2GseiRf3toJn6embhMJYcWNcZuwlwpQ%3d%3d 1/2 2/17/2021 Florida Building Code Online Product Approval Method Method 2 Option A Date Submitted 11/20/2020 Date Validated 11/23/2020 Date Pending FBC Approval Date Approved 11/24/2020 Summary of Products FL# Model,Number or Name Description 35321.1 TAMKO Asphalt Shingles Non-ASTM D3462 asphalt roof shingles and ridge cap shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL35321 RO II 2020 11 18 TAMKO UL ER2919-02.pdf Approved for use outside HVHZ: Yes Verified By: UL LLC Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: Refer to UL ER Section 8 for Limits of Use. FL35321 RO AE 2020 11 18 TAMKO UL ER2919-02.pdf Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® ® ® eCi Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqugTpvOGuj4wUr2GseiRf3toJn6embhMJYcWNcZuwlwpQ%3d%3d 2/2 UL Evaluation Report UL E R2919-02 Issued: April 25, 2014 Revised: November 18, 2020 Visit UL, LLC's Product iQT" database for the status of this Report. UL Category Code: ULEZ CSI MasterFormat® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Sub-level 2: 07 30 00—Steep Slope Roofing Sub-level 3: 07 31 00—Shingles and Shakes Sub-level 4: 07 31 13—Asphalt Shingle COMPANY: i TAMKO BUILDING PRODUCTS LLC 198 FOUR STATES DRIVE GALENA, KANSAS 66739 (417) 624-6644 www.tamko.com 1. SUBJECT: Asphalt Shingles ELITE GLASS-SEAL HERITAGE, HERITAGE IR, HERITAGE PREMIUM, HERITAGE WOODGATE, HERITAGE VINTAGE, AND HERITAGE PROLINE TITAN XT HERITAGE VINTAGE 12 X 12 HIP AND RIDGE, 12-1/4 X 12 HIP AND RIDGE AND 12-1/4 X 12 HERITAGE HIP AND RIDGE IR HERITAGE VINTAGE STARTER 2. SCOPE OF EVALUATION ■2018, 2015, 2012, and 2009 International Building Code®(IBC) ■2018, 2015, 2012, and 2009 International Residential Code®(IRC) ■2020 Florida Building Code— Building ■2020 Florida Building Code— Residential ■ ICC ES Acceptance Criteria for Quality Documentation (AC10) ■ ICC ES Acceptance Criteria for Alternative Asphalt Roofing Shingles (AC438) The products were evaluated for the following properties: ■Exterior Fire Exposure (UL790, ASTM E108) ■Wind Resistance (ASTM D3161; ASTM D7158) ■Physical Properties (ASTM D3462, ICC ES AC438) ■Impact Resistance (UL 2218) 3. REFERENCED DOCUMENTS ■ UL790 (ASTM E108), Standard Test Methods for Fire Tests of Roof Coverings Eighth Edition, dated October 19, 2018 ■ UL 2218, Standard Test Methods for Impact Resistance of Prepared Roof Covering Materials ■ ASTM D3161, Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method) ■ ASTM D7158, Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift Force/Uplift Resistance Method) ■ UL Subject 2375 Issue No. 2, Outline of Investigation for Hip and Ridge Shingles (UL Fire and Wind Tests) ■ ICC ES Acceptance Criteria for Alternative Asphalt Roofing Shingles (AC438) ■ ICC ES Acceptance Criteria for Quality Documentation (AC10) 4. USES TAMKO asphalt shingles described in this report are alternatives to asphalt shingles complying with Section 1507.2.4 of the 2018 IBC, Section 1507.2.5 of the 2015, 2012, and 2009 IBC, Section 1507.2.5 of the 2020 Florida Building Code- Building, or Section R905.2.4 of the IRC and 2020 Florida Building Code - Residential, and are Class A roof coverings for new and existing roofs. 5. PRODUCT DESCRIPTION TAMKO asphalt shingles are roof covering materials complying with the following properties when installed as described in this report. The products are three-tab shingles, laminated shingles and hip and ridge shingles. Fire Classification: TAMKO asphalt shingles covered under this Report have been tested for fire classification Class A in accordance with UL 790 (ASTM E108). Shingles tested in accordance with UL790 (ASTM E108)qualify for use under Section 1505.1 of the 2020 Florida Building Code - Building, IBC, -Section R902.1 of the IRC and 2020 Florida Building Code- Residential. Wind Resistance: TAMKO asphalt shingles covered under this Report have been tested for wind resistance in accordance with ASTM D3161 or ASTM D7158. Shingles tested in accordance with ASTM D3161 are classified as Class F and qualify for use under the exception to Section 1504.1.1 of the 2018 and 2015 IBC and Section 1507.2.7.1 of the 2012 and 2009 IBC and 2020 Florida Building Code- Building, the exception to Section R905.2.4.1 of the IRC, and Section R905.2.4 of 2020 Florida Building Code - Residential. Shingles tested in accordance with ASTM D7158 are classified as Class H and qualify for use in locations as shown in Table 1507.2.7.1 of the 2012, 2009 IBC and 2020 Florida Building Code - Building, Table R905.2.4.1 of the 2012 and 2009 IRC, or Table R905.2.6.1 of the 2020 Florida Building Code - Residential, where the maximum basic wind speed is 150 mph (67 m/s) or less with exposure category of B or C (ASCE 7)and a maximum building height of 60 feet (18.3 m). Installation must be in accordance with Section 1507.2.6 of the 2018 IBC and Section 1507.2.7 of the 2015, 2012, and 2009 IBC, or Section R905.2.6 of the 2018, 2015, 2012, and 2009 IRC, as applicable. Page 2 of 18 Physical Properties: TAMKO asphalt shingles covered under this Report have been tested for physical properties in accordance with ICC ES AC438. Shingles tested in accordance with ICC ES AC438 qualify as an alternative roof covering for use under Section 1507.2.4 of the 2018 IBC, Section 1507.2.5 of the 2015, 2012, and 2009 IBC, Section 1507.2.5 of the 2020 Florida Building Code - Building, or Section R905.2.4 of the IRC and 2020 Florida Building Code - Residential. When installed on new construction in accordance with this report and the TAMKO Building Products LLC installation instructions, the shingles are a Class A roof covering. When the shingles are installed over existing roof coverings, the Class A fire classification is maintained. 5.1 Three-Tab Shingles—Elite Glass-Seal: Elite Glass-Seal shingles are three-tab shingles manufactured with a single fiberglass mat, coated on both sides with asphalt, and surfaced on the weather-exposed side with mineral granules. The shingles are self-sealing and have beads of thermal-tab sealing adhesive above the shingle butt on the weather side. See Table 2 for product dimensions and manufacturing locations. 5.2 Laminated Shingles— Heritage, Heritage IR, Heritage Premium, Heritage Woodgate, Heritage Vintage, and Heritage Proline Titan XT: Heritage, Heritage IR, Heritage Premium, Heritage Woodgate, Heritage Vintage, and Heritage Proline Titan XT shingles are laminated shingles manufactured with a double layer of fiberglass mats coated with asphalt on all sides, and surfaced on the weather-exposed side with mineral granules. See Table 3, Table 4 Table 5, Table 6, Table 7, Table 10 and Table 13 for product dimensions and manufacturing locations. 5.3 Hip & Ridge Shingles— 12-1/4 X 12 Hip and Ridge, Heritage Vintage 12 X 12 Hip and Ridge, 12-1/4 X 12 Heritage Hip and Ridge IR: 12-'/4 X 12 Hip and Ridge, Heritage Vintage 12 X 12 Hip and Ridge, and 12-'/4 x 12 Heritage Hip and Ridge IR shingles are prefabricated hip and ridge shingles. Heritage Vintage 12 X 12 Hip and Ridge shingles are perforated so they can be torn into three 12-inch by 12-inch shingles. The 12-1/4 X 12 Hip and Ridge and 12-'/4 X 12 Heritage Hip and Ridge IR shingles are perforated so they can be torn into three 12-'/4 inch by 12-inch shingles. As an alternative, Elite Glass-Seal shingles are cut into three 12-'/4 inch by 12-inch hip and ridge shingles. See Table 8, Table 9, and Table 11 for product dimensions and manufacturing locations. 6. INSTALLATION TAMKO asphalt shingles must be installed in accordance with the applicable code, this report and the manufacturer's published installation instructions. The shingles must be installed in accordance with Section 1507.2 of the IBC and 2020 Florida Building Code - Building, or Section R905.2 of the IRC and 2020 Florida Building Code- Residential, as applicable, except as noted in this report. The manufacturer's published installation instructions must be available at all times on the jobsite during installation. Minimum roof slopes must be 2:12 (16.67% slope)for the three-tab shingles described under 5.1 of this Report and for the laminated shingles described under 5.2 of this Report. Page 3 of 18 6.1 Underlayment and Ice Barriers: For roof slopes 4:12 and greater, the roof deck must be covered with a minimum of one layer of underlayment as described in Sections 7.2 and 7.3 of this Report. Underlayment application must be in accordance with Table 1507.1.1 of the 2018 IBC, 2020 Florida Building Code - Building, and Section 1507.2.8 of the 2015, 2012, and 2009 IBC or Section R905.2.7 of the IRC and Section 905.2.3 of the 2020 Florida Building Code - Residential, as applicable. For roof slopes 2:12 and up to but less than 4:12, two layers of the underlayment described in Section 7.2 or one layer of the self-adhering polymer modified bitumen sheet in described in Section 7.3 of this Report are required. Underlayment application must be in accordance with Section 1507.1.1 of the 2018 IBC, 2020 Florida Building Code - Building, and Section 1507.2.8 of the 2015, 2012, and 2009 IBC, Section R905.1.1 of the IRC, and 2020 Florida Building Code- Residential, as applicable. In areas where there has been a history of ice forming along the eaves, causing a backup of water, an ice barrier must be provided in accordance with Section 1507.1.2 of the 2018 IBC and Section 1507.2.8.2 of the 2020 Florida Building Code - Building, 2015, 2012, and 2009 IBC or Section R905.2.7 of the 2018 IRC, 2020 Florida Building Code- Residential, and Section R905.16.4.1 2015 IRC, and Section R905.2.7.1 of the 2012, and 2009 IRC, as applicable. 6.2 Starter Shingle: A starter course, as described in Section 7.4 of this Report, must be attached to the eave edge using fasteners described in Section 7.5 of this Report, located 1-'/2 to 3 inches (38.1 to 76.2 mm) from the eave edge and spaced 1 inch (25.4 mm) and 12 inches (305 mm)from each end, for a total of four fasteners per shingle. Starter strips must overhang the eave and rake edges '/4 to 3/4 inch (6.4 to 19.1 mm) if no drip edge flashing is present. If drip edge flashing is present, install shingles even with the drip edge or overhang the drip edge up to% inch. 6.3 Asphalt Shingles: The first course of field shingles must be installed over the starter course described in Section 7.4 of this Report. Shingles must be installed with vertical joints offset a minimum of 4 inches (102 mm)from adjacent courses. 6.3.1 Three-Tab Shingles— Elite Glass-Seal: For roof slopes 2:12 up to but less than 21:12 (16.67% to 175% slope), each shingle must be fastened to the roof deck using a minimum of four fasteners, spaced as shown in Tables 2 and 3. For roof slopes equal to or greater than 21:12 (175% slope), six fasteners must be used, spaced as shown in Table 2. Fasteners must be in a nail area between 5-% inches (143 mm)and 6'/8 inches (175 mm) from the butt edge of the shingle. Maximum exposure to the weather must be 5-'/8 inches (130 mm). In colder climates or wind regions where it is questionable whether the thermal-sealing adhesive will activate to seal the shingles, the shingles can be hand-sealed. A 1-in diameter (25.4 mm)spot of asphalt cement complying with ASTM D4586, Type I, Class I, should be placed under the corner of each tab (two spots per tab). Page 4 of 18 6.3.2 Laminated Shingles— Heritage, Heritage IR, Heritage Premium, Heritage Woodgate, and Heritage Proline XT: For roof slopes 2:12 up to but less than 21:12 (16.67% to 175% slope), each shingle must be fastened to the roof deck using a minimum of four fasteners, spaced as shown in Tables 3, 4, 5, 6, 10 and 13. For roof slopes over 21:12 (175% slope), six fasteners must be used, spaced as shown in Tables 3, 5, 6, 10, and 13. Maximum exposure to the weather must be 5% inches (143 mm). In colder climates or wind regions where it is questionable whether the thermal-sealing adhesive will activate to seal the shingles, the shingles can be hand-sealed. Four evenly spaced 1-inch diameter(25.4 mm)spots of cement should be placed under the exposed portion of the shingle, approximately 1 inch (76 mm) above the butt edge. 6.3.3 Laminated Shingles—Heritage Vintage: For roof slopes 2:12 up to but less than 21:12 (16.67% to 175% slope), each shingle must be fastened to the roof deck using a minimum of five fasteners, spaced as shown in Table 7. For roof slopes equal to or greater than 21:12 (175% slope), nine fasteners must be used, spaced as shown in Table 7. Fasteners must be located 6 and 11-1/2 inches (152 and 292 mm) above the butt edge of the shingles. Maximum exposure to the weather must be 5 inches (127 mm). In colder climates or wind regions where it is questionable whether the thermal-sealing adhesive will activate to seal the shingles, the shingles must be hand-sealed. Four evenly spaced 1-inch diameter(25.4 mm)spots of cement should be placed under the exposed portion of the shingle, approximately 1 inch (127 mm) above the butt edge. 6.4 Valley Construction and Other Flashing: Valleys must consist of woven, open valley or closed-cut construction and must be flashed in accordance with Section 1507.2.8.2 of the 2018 IBC, and Section 1507.2.9.2 of the 2020 Florida Building Code - Building, 2015, 2012, and 2009 IBC or Section R905.2.8.2 of the IRC and 2020 Florida Building Code - Residential. Other flashings must be in accordance with Sections 1503.2 and 1507.2.8 of 2020 Florida Building Code - Building, 2018 IBC, Section 1507.2.9 of the 2015, 2012, and 2009 IBC, or Section R903.2 and Section R905.2.8 of the IRC and 2020 Florida Building Code - Residential, as applicable. 6.5 Hip and Ridge Application: Hip and ridge shingles must be placed evenly over hips and ridges, and must be fastened to the roof deck using two fasteners, one located on either side of the shingle, 5-1/2 inches (140 mm) or 5-% inches (143 mm) from the exposed end, and 1 inch (25.4 mm) in from the edge as shown in Tables 8 and 9. Fasteners must be a minimum '/4 inch (6.4 mm) longer than those used in the field of the roof, as specified in Section 7.5 of this report. The 12-'/4 X 12 Hip and Ridge and 12-'/4 x 12 Heritage Hip and Ridge IR prefabricated hip and ridge shingles must be installed with a maximum exposure of 5-1/in. (130 mm). Heritage Vintage 12 X 12 Hip and Ridge prefabricated hip and ridge shingles must be installed with a maximum exposure of 5 in. (127 mm). Hip and ridge shingles are installed starting at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing wind. Page 5 of 18 6.6 Reroofing: The existing asphalt shingle roof covering must be inspected in accordance with the provisions and limitations of Section 1510 of the IBC, Section 1511 of the 2020 Florida Building Code - Building, Section R908.1 of the IRC, or Section 901.1 of the 2020 EBC-Residential, as applicable. Prior to the reroofing, hip and ridge coverings must be removed. Except as noted in this section, the shingles must be installed in accordance with Section 6.3 and 6.5 of this Report. Fasteners must be of sufficient length to penetrate 3/4 inch (19.1 mm) into the sheathing, or through the sheathing where the sheathing is less than 3/4 inch (19.1 mm) thick. Flashing and edging must comply with Section 6.4 and with Section1511.6 of the 2018 and 2015 IBC and 2020 Florida Building Code - Building, Section 1510.6 of the 2012, and 2009 IBC and Section R908.6 of the 2018 and 2015 IRC, 2020 Florida Building Code - Residential, and R907.6 of the 2012, and 2009 IRC, as applicable. 7. INSTALLATION MATERIALS 7.1 Sheathing: The roof deck must be code-complying, minimum 3/8-inch thick (9.5 mm), exterior plywood complying with DOC PS-1; rated sheathing complying with DOC PS-2; or solid sheathing using minimum nominally 1 by 6 lumber. 7.2 Underlayment: Under the IBC or IRC, underlayment must comply with ASTM D226, Type I (minimum), ASTM D4869, Type I (minimum) or ASTM D6757 as specified in Section 1507.1.1 of the 2020 Florida Building Code - Building, Section 1507.2.3 of the IBC or Section R905.1.1 of the IRC, and 2020 Florida Building Code - Residential. 7.3 Self-adhering Polymer Modified Bitumen Sheet: The self-adhering polymer modified bitumen sheet must comply with ASTM D1970. 7.4 Starter Shingles: The starter course shingle consists of either TAMKO 10-inch starter, TAMKO Shingle Starter, TAMKO Perforated Starter,or a self-sealing three-tab shingle. If self-sealing three-tab shingles are used, remove the exposed tab portion and install with factory-applied sealant adjacent to the eaves. Heritage Vintage requires a Heritage Vintage starter shown in Table 12 is to be installed over the starter course at the eave edge. 7.5 Fasteners: Fasteners must be minimum No. 12 gage [0.105 inch (2.7 mm)], 3/8-inch diameter head (9.5 mm), galvanized, stainless steel, aluminum or copper corrosion-resistance nails. Fasteners must be of sufficient length to penetrate into the sheathing%-inch (19.1 mm), or through the sheathing, where the sheathing is less than 3/4-inch (19.1 mm)thick. Fasteners must be compliant with ASTM F1667. 7.6 Asphalt Cement: Asphalt cement must comply with ASTM D 4586, Type I, Class I. Page 6 of 18 8. CONDITIONS OF USE The TAMKO Asphalt Shingles described in this Report comply with, or are suitable alternatives to, what is specified in those codes listed in Section 2 of this Report, subject to the following conditions: 8.1 Materials and methods of installation shall comply with this Report and the manufacturer's published installation instructions. In the event of a conflict between the installation instructions and this Report, this Report governs. 8.2 The products are manufactured at the locations listed in Table 1 of this Report under the UL LLC Classification and Follow-Up Service Program, which includes regular audits in accordance with quality elements of ICC-ES Acceptance Criteria for Quality Documentation, AC10. 8.3 See UL Product iQTM database for Prepared Roof-Covering Materials (TFWZ). 9. SUPPORTING EVIDENCE 9.1 Manufacturer's descriptive product literature, including installation instructions. 9.2 See UL Product iQTM database for the following: 9.2.1 UL test reports and Classification in accordance with UL 790, Class A and UL Subject 2375 for Roof-Covering Materials (TFWZ). 9.2.2 UL test reports and Classification in accordance with ICC ES Acceptance Criteria for Alternative Asphalt Roofing Shingles, AC438. (TFWZ). 9.2.3 UL test reports and Classification in accordance with ASTM D7158, Class H for Prepared Roof-Covering Materials (TGAH). 9.2.4 UL test reports and Classification in accordance with ASTM D3161, Class F Prepared Roof-Covering Materials (TFWZ). 9.3 Quality Documentation in accordance with ICC-ES Acceptance Criteria for Quality Documentation, AC10. 10. IDENTIFICATION TAMKO asphalt shingles described in this Evaluation Report are identified by a marking on each package bearing the report holder's name (TAMKO Building Products LLC), the plant identification, the product name, the UL Listing/Classification Mark and the evaluation report number UL ER2919-02. The validity of this Evaluation Report is contingent upon this identification appearing on the package. 11. USE OF UL EVALUATION REPORT 11.1 The approval of building products, materials or systems is under the responsibility of the applicable authorities having jurisdiction. 11.2 UL Evaluation Reports shall not be used in any manner that implies an endorsement of the product, material or system by UL. 11.3 The status of this report, as well as a complete directory of UL Evaluation Reports may be found at UL.com via the Product iQTM database. Page 7 of 18 Table 1 - Manufacturing Locations LISTEE LOCATION FACTORY ID TAMKO BUILDING PRODUCTS LLC 7910 S CENTRAL EXPY D DALLAS TX 75216 TAMKO BUILDING PRODUCTS LLC 4500 TAMKO DR F FREDERICK MD 21704 TAMKO BUILDING PRODUCTS LLC 601 N HIGH ST J JOPLIN MO 64801 TAMKO BUILDING PRODUCTS LLC 1598 HWY 183 P PHILLIPSBURG KS 67661 KAUL INDUSTRIAL PARK TAMKO BUILDING PRODUCTS LLC 2300 35TH ST T TUSCALOOSA AL 35401 Table 2- Elite Glass-Seal Dimensions: 12-'/4" x 36" ------------------------T---------------------------------------- ------------------------------- Plant Location(s): Frederick, Joplin ------------------------r----------------------------------------------------------------------------------------- For slopes 2:12 up to but less than 21:12 NAILS Fastening Pattern: Nailing - - - - - - - ---------------�__ 6-718 - - - - - - - - - - - - ----------- - Area — hut# Ec:{;��:� -----------------------+----------------------------------------------------------------------------------------- For slopes equal to or greater than 21:12 NAILS —fin 1 r Fastening Pattern: ---j------------------------ --------------------------�. - Nailing -- ------- ------ Area - --------------------------------------------------------------------`-------------------------------- ------ 7-5i8' Butt Edge Page 8 of 18 Table 3— Heritage Dimensions: 13-1/"x 39 3/8" -----------------------r----------------------------------------------------------------------------------------- Plant Location(s): Dallas, Frederick, Joplin, Phillipsburg -----------------------r----------------------------------------------------------------------------------------- For slopes between 2:12 up to but less than 21:12 NAIL ZONE FASTENERS COMMCNBCND Fastening Pattern: 6-1/8" EXPOSURE 5-5/8 1 12-1/2" 12-3/8" 12-112 ------------------------r----------------------------------------------------------------------------------------- For slopes equal to or greater than 21:12 NAIL ZONE FASTENERS COMMON BOND Fastening Pattern: "1D Ll Li EXPOSURE 5-518, Page 9 of 18 ---------------------------- ---Table 4--Heritage............................................... Dimensions: 13-1/4"x 39-3/8" ------+----------------------------------------------------------------------------------------- Plant Location(s): Tuscaloosa ---+----------------------------------------------------------------------------------------- For slopes between 2:12 up to but less than 21:12 12-1/2" — 12-3/8" a 12-1/2" I -V PAINT PREFERRED FASTENER LOCATIONS LINE 7_711311 }NAIL ZONE EDGE OF Fastening Pattern: COMMON BOND EXPOSURE ACCEPTABLE 5-FAI I FASTENER LOCATION DO NOT FASTEN ALONG EDGE OF COMMON BOND PREFERRED FASTENER -LOCATION -----------------------r----------------------------------------------------------------------------------------- For slopes equal to or greater than 21:12 NAIL ZONE FASTENERS • COMMON BOND Fastening Pattern: 8-118" L] Ll L EXPOSURE 5-518" 1� �+7-112'�F T-i{7"-Y�F 7-3J8"�7-112"�T-112'-►I �1" Page 10 of 18 Table 5—Heritage Premium Dimensions: 13-1/"x 39 3/8" -----------------------r----------------------------------------------------------------------------------------- Plant Location(s): Phillipsburg, Frederick -----------------------r----------------------------------------------------------------------------------------- For slopes between 2:12 up to but less than 21:12 NAIL ZONE FASTENERS COMMCNBCND Fastening Pattern: 6-1/8" EXPOSURE 6-5/8 1 12-1/2" 12-3/8" 12-112 ------------------------r----------------------------------------------------------------------------------------- For slopes equal to or greater than 21:12 NAIL ZONE FASTENERS COMMON BOND Fastening Pattern: L Ll Ll EXPOSURE 5-5+8' 1 H-7-1112- F 7-112"-k-� 7-318' 7-112'-*�*-7-112' 1' Table 6— Heritage Wood ate Dimensions: 13-'/"x 393/8" ------------------------r----------------------------------------------------------------------------------------- Plant Location(s): Dallas, Frederick -----------------------r----------------------------------------------------------------------------------------- For slopes of 2:12 up to but less than 21:12 NAIL ZONE! FASTENERS COMMONBOND Fastening Pattern: 6-118" EXPOSURE 5.5l3" V. 12-112' 12-318" 12-112"—+-1„ -----------------------+----------------------------------------------------------------------------------------- For slopes equal to or greater than 21:12 NAIL ZONE/ ASTENERS COMMONBOND Fastening Pattern: T 6-11W EXPOSURE 5 5'13" 1 {-112^ T-1!L"-►�-7 31� 7 112 T 1f2�-►I �—v Page 11 of 18 Page 12o/18 Table 8— Heritage Vintage 12 X 12 Hip and Ridge Dimensions: 12" x 12" -----------------------r----------------------------------------------------------------------------------------- Plant Location(s): Phillipsburg -------------------------r----------------------------------------------------------------------------------------- Neils 12" rI • Fastening Pattern: 1 in �, I 5" 5 1�2" Exposure 12" Page 13 of 18 Table 9— 12'/4 X 12 Hip and Ridge Dimensions: 12-'/4"x 12" ------------------------r----------------------------------------------------------------------------------------- Plant Location(s): Frederick, Joplin ------------------------r----------------------------------------------------------------------------------------- Nails 124/47 1 in. in_ Fastening Pattern: 1 f$" 5 5W Exposure 12" Page 14 of 18 Table 10—Heritage IR Dimensions: 13-'/4" x 39 3/8" -----------------------r----------------------------------------------------------------------------------------- Plant Location(s): Joplin, Philipsburg -----------------------r----------------------------------------------------------------------------------------- For slopes between 2:12 up to but less than 21:12 NAIL ZONE FASTENERS COMMONBOND Fastening Pattern: 1 EJ 1-1 fi-1l8" EXPOSURE 5-5f8' 1 12-1/2" 12-3/8" 12-112 -----------------------r----------------------------------------------------------------------------------------- For slopes equal to or greater than 21:12 NAIL ZONE FASTENERS COMMON BOND Fastening Pattern: 6 118" EXPOSURE:5-518'Ll Ll 1 �-7-112 L�F 7-1 f2"+� 7-319" 7-112`1�4-7-112" 1„ Page 15 of 18 Table 11 Heritage Hip and Ridge IR Dimensions: 12-/�" x 12" ------------------------r----------------------------------------------------------------------------------------- Plant Location(s): Joplin -------------------------r----------------------------------------------------------------------------------------- Nails Fastening Pattern: 12-1/4" I� 1 in_ 1 in. 5 118" 5 518" Exposure 12" Table 12 Heritage Vintage Starter p_ -V: " eo n c N Page 16 of 18 Table 13— Heritacie Proline Titan XT Dimensions: 13-'/4"x 39 3/8" -----------------------r----------------------------------------------------------------------------------------- Plant Location(s): Philipsburg and Frederick --------------- For slopes 2:12 up to but less than 21:12 12-1/2"-� 12-3/8"—I= 12.1/2" 1i� Preferred Fastener Locations `v }Nail Zone 5T5/8" Paint Lines r~ Exposure Fastening Pattern 7 Iji ) 39-3/S" Acceptable Fastener Location Preferred Fastener Location r -- ------- ---- For slopes equal to or greater than 21:12 �8-1/2"— &1/2"� 1i Required Fastener Locations rh + —Nail Line �0 5t5/8" Paint Lines Fastening Pattern: Exposure 39-3/8" - �i TT Required Fastener Location Page 17 of 18 ©2020 UL LLC This UL Evaluation Report is not an endorsement or recommendation for use of the subject and/or product described herein. This report is not the UL Listing or UL Classification Report that covers the subject product. The subject product's UL Listing or UL Classification is covered under a separate UL Report. UL disclaims all representations and warranties whether express or implied, with respect to this report and the subject or product described herein. Contents of this report may be based on data that has been generated by laboratories other than UL that are accredited as complying with ISO/IEC Standard 17025 by the International Accreditation Service (IAS) or by any other accreditation body that is a signatory to the International Laboratory Accreditation Cooperation (ILAC) Mutual Recognition Arrangement (MRA). The scope of the laboratory's accreditation shall include the specific type of testing covered in the test report. As the accuracy of any non-UL data is the responsibility of the accredited laboratory, UL does not accept responsibility for the accuracy of this data. U` Page 18 of 18