HomeMy WebLinkAboutAPPROVED, Design Pressure Report (Ken and Tara Beck)Property Information
Owner:Ken and Tara Beck
Address:10680 S Ocean Dr 105
St. Lucie County,
Building Information
Wind Zone:180 MPH.
Exposure Category:D
Minimum Building Dimension:35 ft.
Mean Roof Height:20 ft.
Risk Category:II
Design Pressure Calculations
Opening
Number
Location
Zone
Device
Width (in)
Device
Height (in)
Device
Elevation (ft)
Max Positive
Pressure (psf)
Max Negative
Pressure (psf)
1 Int 52.75 62.75 7 60.2 -65.6
2 Int 52.75 62.75 7 60.2 -65.6
Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code.