HomeMy WebLinkAboutAPPROVED, Design Pressure Report (Ken and Tara Beck)Property Information Owner:Ken and Tara Beck Address:10680 S Ocean Dr 105 St. Lucie County, Building Information Wind Zone:180 MPH. Exposure Category:D Minimum Building Dimension:35 ft. Mean Roof Height:20 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 52.75 62.75 7 60.2 -65.6 2 Int 52.75 62.75 7 60.2 -65.6 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1