Loading...
HomeMy WebLinkAboutDrawing 5-29-20"EXISTING CCINDITIONS PORT ST. LUCIE FL 349152 7159 LJS=l GENERAL NOTES THESE DRAWINGS WERE PREPARED WITH THE ASSUMPTION THAT THE CONRACTOR/BUiLDER IS KNOWLEDGEABLE OF COMMON CONSTRUCTION PRACTICES. THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES IN WRITING PRIOR TO SUBMITTING HIS BID. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO THE SUBMISSION OF ANY BIDS, AND VERIFY THE ARCHITECTS DIMENSIONS, DETAILS AND INFORMATION PERTAINING TO THE PROJECT. IF ANY DISCREPANCIES, CONFLICTING INFORMATION, ERRORS OR OMISSIONS ARE PRESENT, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND OWNER IMMEDIATELY IN WRITING. ANY DISCREPANCY, OR CONFLICT NOT BROUGHT TO THE ATTENTION OF THE ARCHITECT AND OWNER PRIOR TO THE FINAL BID SUBMISSION SHALL BE CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. THE CONTRACTOR SHALL NOT SCALE THE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL CARRY PUBLIC LIABILITY, PROPERTY, AND WORKMEN'S COMPENSATION INSURANCE. VALID CERTIFICATES OF ALL SHALL BE PROVIDED. THE CONTRACTOR SHALL INCLUDE ALL WORK NECESSARY TO ASSURE THE PROJECTS COMPLIANCE WITH THE MOST STRINGENT REQUIREMENTS OF THE FLORIDA BUILDING CODE, CURRENT LOCAL EDITION, NFPA-101 AND ALL OTHER REGULATION CODES. THE CONTRACTOR SHALL OBTAIN ALL PERMITS, AND SECURE ALL CERTIFICATES OF INSPECTION AND OCCUPANCY THAT ARE REQUIRED BY THE GOVERNING JURISDICTION. THE OWNER SHALL RECEIVE A COPY OF THE PERMIT UPON ISSUANCE. THE CONTRACTOR SHALL REFERENCE THE BUILDING SHELL DRAWINGS FOR ALL INFORMATION RELATIVE TO THE BUILDING SHELL AND FOR COORDINATION OF NEW WORK. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORSNENDORS SMALL FAMILIARIZE THEMSELVES WITH AND CONFORM TO ALL REQUIREMENTS SET FORTH BY THE BUILDING OWNER OR MUNICIPALITY RELATIVE TO THE HOURS OF WORK. THE CONTRACTOR SHALL SUBMIT A DETAILED CONSTRUCTION SCHEDULE COORDINATION ALL SUBCONTRACTORS, SUPPLIERS AND VENDORS. THE CONTRACTOR SHALL NOT ALLOW ON THE PROJECT ANY MATERIALS CONTAINING ASBESTOS, PETROLEUM OR PCB. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND DISTRIBUTING ALL CURRENT DRAWINGS TO THE SUBCONTRACTORS/VENDORS AS WELL AS SUPERVISING AND COORDINATING THE WORK OF ALL TRADES IN ACCORDANCE WITH THE SPECIFICATIONS AND MAKING ADJUSTMENTS IN LAYOUT AS REQUIRED. THE ARCHITECT SHALL BE NOTIFIED PRIOR TO THE EXECUTION OF THEIR REVISIONS TO AVOID CONFLICT BETWEEN TRADES FOR PROPER EXECUTION OF THE WORK. THE CONTRACTOR SHALL INSTALL ANY APPARATUS, APPLIANCE, MATERIAL OR WORK NOT SHOWN ON THE DRAWINGS BUT MENTIONED IN THE SPECIFICATIONS, OR VICE VERSA, OR ANY INCIDENTAL ;ACCESSORIES NECESSARY FOR COMPLETION OF THE WORK FOR OPERATION WITHOUT ADDITIONAL EXPENSE TO OWNER. THE CONTRACTOR SHALL COORDINATE ALL OWNER/TENANT SUPPLIED ITEMS AND INCORPORATE THE INSTALLATION INTO THE CONSTRUCTION SCHEDULE. THE CONTRACTOR SHALL PROVIDE ANY TEMPORARY UTILITIES INCLUI )ING, ELECTRICAL, WATER, AND TELEPHONE REQUIRED FOR THE COMPLETION OF THE PROJECT. OWNER. THE CONTRACTOR SHALL HAVE A DITIGITAL CAMERA ON SITE TO DOCUMENT ANY ISSUES THAT MAY NEED TO BE CLARIFIED. THESE PICTURES SHALL BE EMAILED TO THE ARCHITECT ALONG WITH AN RIFI FOR CLARIFICATION. THE CONTRACTOR SHALL PROVIDE AT ALL TIMES PROTECTION FROM THE WEATHER AND EXCESSIVE DUST THAT MAY IN ANY WAY DAMAGE THE WORK, MATERIAL, FIXTURES, AND EQUIPMENT, OR PRESENT DANGER TO PERSONNEL. ANY WORK UNDER CONTRACT BY THE GENERAL CONTRACTOR DAMAGED BY A FAILURE TO PROVIDE ADEQUATE PROTECTION SHALL BE REMOVED AND REPLACED WITH NEW WORK AT THE SOLE EXPENSE OF THE CONTRACTOR. THE CONTRACTOR SHALL MAINTAIN THE JOB SITE FREE FROM RUBBISH AND DEBRIS. DISPOSAL. OF ALL CONSTRUCTION DEBRIS SHALL CONFORM TO BUILDING REGULATIONS. THE CONTRACTOR SHALL RUN FIRE RATED WALLS AND PARTITIONS TO UNDERSIDE OF RATED ROOF/CEILING ASSEMBLY ABOVE: TAPE AND SEAL JOINTS. PROVIDE FIRE DAMPERS AT DUCT PENETRATIONS AS REQUIRED BY CODE. TAPE AND SEAL OTHER PENETRATIONS TO MAINTAIN INTEGRITY OF FIRE -RATED PARTITION USING ONLY UL APPROVED MATERIAL. THE CONTRACTOR SHALL FINISH GYPSUM WALLBOARD ABUTTING OTHER MATERIAL WITH METAL EDGE STRIPS. CONCEAL PIPING, DUCTWORK, AND CONDUIT. THE CONTRACTOR SHALL BACK ALL ELECTRICAL CABINETS, FIRE EXTINGUISHERS, CABINETS AND OTHER RECESSED EQUIPMENT LOCATED IN FIRE -RATED WALLS WITH 5/8"TYPE 'X' GYPSUM BOARD AS REQUIRED TO MAINTAIN THE RATING. THE CONTRACTOR SHALL PROVIDE BRACING OR BLOCKING AS REQUIRED TO SUPPORT WALL MOUNTED EQUIPMENT: CABINETS, GRILLES, DOORS, WINDOWS, ETC.. WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED. METAL STUDS MAY BE USED IN LIEU OF WOOD BLOCKING. THE CONTRACTOR SHALL NOT CUT ANY STEEL, WOOD, OR OTHER MAIN STRUCTURAL MEMBERS WITHOUT WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER. ANY ROOM, WALL, FLOOR, OR CEILING FINISH NOT SCHEDULED SHALL BE ASSUMED TO BE IDENTICNTICAL TO THE CLOSEST ROOM OF SIMILAR USE AND TYPE FOR PURPOSES OF BIDDING AND CONSTRUCTION. NOTIFY THE ARCHITECT OF ANY OBSERVED APPARENT DISCREPANCIES IN WRITING PRIOR TO COMMENCING WITH THE WORK. ANY DETAIL NOT SPECIFICALLY REFERENCED SHALL BE ASSUMED TO BE SIMILAR TO THAT SHOWN IN THE CLOSEST POSITION WHERE A SIMILAR CONDITIONS OCCURS FOR THE PURPOSES OF BIDDING AND CONSTRUCTION. NOTIFY THE ARCHITECT IN WRITING OF ANY OBSERVED APPARENT DISCREPANCIES PRIOR TO COMMENCING WITH THE WORK. WHERE TWO OR MORE DETAILS, MATERIALS, OR CONDITIONS OCCUR IN APPARENT CONFLICT, THE CONTRACTOR SHALL INCLUDE THE MOST COSTLY SOLUTION IN HIS BID AND NOTIFY THE ARCHITECT OF ANY APPARENT DISCREPANCIES PRIOR TO START OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE UPON COMPLETION OF THE WORK A SET OF "AS -BUILT" NEATLY MARKED UP PLANS, THE ELECTRICAL CONTRACTORS "AS -BUILT" DRAWINGS SHALL BE INCLUDED. THESE DRAWINGS SHALL BE TRANSMITTED TO THE OWNER. OCCUPANCY LOAD CALCULATIONS TENANT SPACE: "NON SEPARATED OCCUPANCIES" GROUP "M" 8,135 S.F./60= GROUP "F" 2,088 S.F./100= MEZZANINE: 1,590S.F./300= TOTAL OCCUPANCY: EGRESS WIDTH: 0.2 X 26=5.2" REQ'D, EXIT ACCESS TRAVEL DISTANCE REQ'D: T MAX. COMMON PATH OF EGRESS TRAVEL: PLUMBING FIXTURES CALCULATIONS 10,223 S.F. "M" OCC. LOAD: 135/2 (M,F): 67.5 67.5 MALE, 67.5 FEMALE WATER CLOSETS 1 /500 M - 11500 F MALE 67.5 OCCUPANTS/500 = 1 FEMALE 67.5 OCCUPANTS/500 = 1 LAVATORIES 1 /750 MALE 67.5 OCCUPANTS/ 750 = 1 FEMALE 67.5 OCCUPANTS/ 750 = 1 DRINKING FOUNTAIN 1 SERVICE SINK 1 "F" OCC. LOAD: 25/2 (M,F): 12.5 12.5 MALE, 12.5 FEMALE WATER CLOSETS 1 /100 M - 1 /100 F MALE 12.5 OCCUPPANTS/500 = 1 FEMALE 12.5 OCCUPPANTS/500 = 1 LAVATORIES 1/100 MALE 12.5 OCCUPANTS/ 750 =1 FEMALE 12.5 OCCUPANTS/ 750 = 1 DRINKING FOUNTAIN 1 SERVICE SINK 1 DETAIL 2 DETAIL INDENTIFICATION # A-02 SHEET WHERE DETAIL IS DRAWN SECTION 2 SECTION INDENTIFICATION # A-02 17 SHEET WHERE SECTION IS DRAWN ELEVATION 2 - —ELEVATION INDENTIFICATION # A-02 SHEET WHERE ELEVATION IS DRAWN INTERIOR ELEVATION A ELEVATION INDENTIFICATION # SHEET WHERE INTERIOR ELEVATION IS DRAWN D I( A-02 B C 1 ) DOOR TAG OWINDOW TAG WALL TYPE ELEVATION MARK PROJECT DATA BUILDING CONSTRUCTION TYPE: TYPE 11 EXISTING FIRE SPRINKLER SYSTEM EXISTING FIRE ALARM SYSTEM OCCUPANCY CLASSIFICATION: BUILDING HEIGHT: BUILDING AREA: PROJECT AREA: ADDRESS: LEGAL DESCRIPTION: FOLIO COMPLIANCE• WORK:CLASSIFICATION OF GROUP " M ", MERCANTILE 1 STORY 84,544 S.F. 10,223 S.F. ST. LUCIE PLAZA 7159 S US HIGHWAY PORT ST. LUCIE, FL 34952 22 36 40 BEG AT SE COR OF NE 1/40F NW 1/4 RUN S 27 DEG 38 MIN E 210 FT TONLI OFRIOMAR DR, TIHS62DEG 22 MIN W 30 FT, TH N 27 DEG 38 MIN W 225.83 FT, TH N 89 DEG 49 MIN W 555.72 FT M/L, TH N 00 DEG 07 MIN E 800 FT, TH S 89 DEG 49 MIN E 400 FT, TH S 00 DEG 07 MIN W 150 FT, TH S 89 DEG 49 MIN E 164.36 FT TO W R/W US 1, THSELY ON R/W 313.79 FT(SAID LINE BEING ON A CURVE AND HAVING A RADIUS OF 1952.08 FT, A CA OF 09 DEG 06 MIN 48 SEC AND A LONG CHORDBEARING OF S 11 DEG 56 MIN 25 SEC E), TH N 89 DEG 49MIN W101.01 FT, TH S 00 DEG 07 MIN W 229.94 FT, TH S 27 DEG 38 MIN E 132.02 FT TO POB (9.95 AC) (OR 2846- 775) 3422-211-0010-000-6 CHANGE OF OCCUPANCY �L LOCATION MAP �nJ to ti i Wvzaly it A W 0 11 ARCHITECTURAL: GN GENERAL NOTES A-1 EXISTING FLOOR PLANS APPLICABLE CODES A. 2017 FLORIDA BUILDING CODE, 6th EDITION C. 2017 FLORIDA MECHANICAL CODE, 6th EDITION A D. 2017 FLORIDA PLUMBING CODE, 6th EDITION E. 2017 NATIONAL ELECTRIC CODE F. 2017 FLORIDA ENERGY CONSERVATION CODE, 6th EDITION G. 2017 FLORIDA ACCESSIBILITY CODE H. 2018 N.F.P.A 1 (UNIFORM FIRE CODE.) 1. 2018 N.F.P.A 101 J. 2017 FLORIDA BUILDING CODE, EXISTING, 6th EDITION Relnaldo A Gomez Architect AR #0013736 16047 Uff 68 ST Revisions 1� 04-28-2020 BLDG DEPT COMMENTS 05-28.2020 BLDG DEPT COMMENTS • 0 inn UM • 1 • am Date Prepared Reviewed By: By: 0200/2020 Author Author SHEET OF GN 3