HomeMy WebLinkAboutRevision 2-19-22NOTE: DOOR FR. SHAL' BE MIN. 4" FR01 SIDEWALL @ CC CONDITION (2) 2x4 WD. HD 2x4 WD. BUCK DOOR -SEE PLAN CAULK FULL 1 PERIMETER, - DOOR HINGE DOOR -SEE PL DOOR -SEE THRESHOLI HEAD JAMB 5/8" MIN. STUCCO FINISH EXIST CMU LINTEL 'FLEXWRAP' FLASHING - TC OR W SCR IF REQ'D BY PROD. APPVL MESH ON M. BARRIER — SEALANT, TYPICAL 1x P.T. WD. SHIM FASTEN TO SOLID 2X FRMG 1/2" GYP. BD, 4-9/16" DOOR FRAME — BOTH SIDES, TYP. EXTERIOR DOOR 1/2" WD. SHIM _ CAS NG D WD EXTERIOR PTD. GRADE WD, FRAME 1/2" GYP. BD. BOTH SIDES, TYP. FINISHED WD CASING (2) 2x4 WD. BUCK PTD. GRADE WD. FRAME ING EXTERIOR DOOR SEALANT, TYP @ FRAME CONT. lx P.T. WD. SHIM FASTEN TO CMU FLASHING GROUT FILL CELL #5 BAR OPENING EXTERIOR DOOR 3/16" TAPCON w/ 1-1/4" EMBEDMENT INTO CONC.-PER HOLE EX DRIVEWAY VC. SLAB - TUCK FLASHING INTO JOINT MIN 1", FILL WITH J1LL FOAM ROPE & SEALANT SILL INTERIOR HINGED DOOR EXTERIOR DOOR Im SCALE: 1-1/2" = V-0" SCALE: 1-1/2"=V-0" - FI-FOIL INSUL 5/8" MIN. STUCCO (R4) FINISH EXIST BOND BEAM -1/2" GYP. BD. -1/4" TC @ 12"oc STAG 'FLEXWRAP' FLASHING - -FURRING STRIPS STUCCO BAND - @ 16" o.c. HORIZ. AROUND OPENING SOLID 2X FRMG, ANCH - TO EXIST LINTEL, WRAP W/ FLASHING WOOD _FIN. CASING MESH ON M. BARRIER — 1x P.T. WD. SHIM CAULK @ FRAME CONT. INTERIOR WINDOW SEALANT, TYPICAL OPTIONAL — PRECAST SILL FI-FOIL INSUL.(R4) 0 1/2" GYP. BD. 1/4" TC @ 12"oc STAG FIN. WOOD CASING 1/2" GYP. BD. w/ CORNER BEAD /4" TAPCON w/ 1-1/2" EMBEDMENT INTO CONC - SPACING PER PRODUCT HEAD APPROVAL y >a VERIFY w/ OWNER FIN. WOOD FIN. WOOD SILL CASING <° 6" STUCCO SILL : FIN. WOOD TRIM w/ DRIP EDGE FURRING STRIPS VERTICAL @ END FURRING STRIPS FLASHING @ 16" o.c. 1/2" GYP. BD. OPT. CMU LINTEL -SEE - FI-FOIL INSUL BEAM/ LINTEL SCHEDULE FI-FOIL INSUL.(R4) (R4) 1w, 1/2" GYP. BD. STUCCO FINISH THRESHOLD PER ILL MANUFACTURER EXTERIOR INTERIOR -GROUT FILL & FLASHING VERIFY SILL W/ - FLOORING WINDOW OWNER 1/2" GYP, BD. CAULK @ FRAME FIN. WOOD CONT. CASING lx P.T. WD. SHIM -EX CONC. SLAB - FASTEN TO CMU FURRING STRIPS STUCCO BAND VARIES VERTICAL @ END FLASHING d 1/2" GYP. BD. GROUT FILL CELL ° a FI-FOIL INSUL.(R4) ALL ]AM B P ONINGS ALUMINUM OR VINYL WINDOW WINDOW &DOOR DETAILS P.T. WOOD FURRING STRIPS @ 16" o.c. HORIZONTALLY 1/2" GYP.BOARD, PTD. FI-FOIL INSULATION (MIN. R-4) FLOOR FINISH - EXIST TIE BEAM & GABLE FRAMING TRUSS BRG. #5 DOWEL EPDXY INTO EXIST CONC. LINTLE & TIE BEAM SCALE: 1-1/2"=V-0" NOTE: 1. WOOD TRIM SHOWN IS OPTIONAL, PER OWNER. 2. MARBLE WINDOW SILLS ARE STANDARD. 5/8" MIN. 2 COAT STUCCO FINISH MATCH EXISTING FINISH #5 VERTICAL REINFORCEMENT IN SOLID GROUTED CELL FROM FOOTING DOWEL TO EPDXY DOWEL IN EXIST LINTLE DOWEL @FILLED CELL, EMBED 8", 6" INTO EXIST FTG, LAP TO #5 VERT. 0'-0" EX HOUSE FIN FLR 6 EX GARAGE FLR \/VA/� e �Ax\ A WALL SECTION @ GAR. DR. IN -FILL - SCALE 3/4" = 1' -0 ACCESS ABOVE CEILING TO INSTALL 2x4 OR 25GA M STUD BRACE WHERE WALL SUPPORT EXCEEDS 8 FT. R30 INSULATION _ __ EX GYP BD @ ROOF TRUSSES SIDE VIER 11 — DBL 2x4 PLATE OR I 20 GA TRACK 11 I I (2) 16d OR #10 X 3" I I W SCR @ EA TRUSS OR BRACE II iINTERIOR WALL SECTION SCALE 3/4" = 1'-0" Product Approval Submittal Affidavit 150 MPH (Lilt) WIND SPEED PER FBC R301.2(2), EXPOSURE 'B' Opening Schedule: Swing Doors & Windows Opening ID Product Model # Manufacturer Glass Description Attachment Method Type, Size, Spacing, & Embedment Building Desi InProduct Pressure (PS`R) Design Pressure (PSF) 1 36" EXTERIOR DOOR FIBER -CLASSIC INSWING IMPACT THERMA-TRU FL #20468-R4 1" LAMINATED INSULATED 1/4" TC THRU 1X PT BUCK W/ 1-1/4" CONC EMBED, 6" ROM HEAD, JAMB, SILL CORNERS, 14"oc EA JAMB, NONE @ Z5, 10SF +24.3/-32.5 + J - 50.0 A SH WINDOW 36"x 49-5/8" 'OCEANVIEW' VINYL, IMPACT VIWINCO, INC. FL #29511-R1 15/16" LAMINATED INSULATED, ANNEALED 1/4" TC THRU 1X PT BUCK, EMBED 1-1/4" INTO GROUTED CONC ELK, W/ 2" MIN EDGE DIST. SAME INTO 2X PT Z5, 10SF +24.3/-32.5 + / - 50.0 Signature: I have reviewed the above product approval information and and approved it. Certification Number: AR 17155 Name: Dan Stuart Davis, Architect w°....m°°are.,�o=a, Date: 6/15/21 4"T.C. THRU 2X PT W/ 1-1/2" EMBED — — FT — INTO EXIST CONC LINTEL 12"oc STAG. 2X SOLID 4" HIGH PT HEADER i THIS ANCHORED TO CONC LINTLE, SAME AT PROJECT DOOR. SEE HEAD DETAILS ON THIS AND SHT 2. 12" max Heao & Sill 411 X X Ia E CL 0 N E f0 (0 r1 C6 W MOP N C L_ 0 U �ro 4" A WINDOW ANCHOR SPACING MASONRY NOTES 1. CONCRETE (where shown) NONE 2. REINFORCING a. shall meet ASTM 615-90 standard for 60 Grade. b. horiz. & Vert. reinforcing lapping shall be a min. 22". c. 1-1/2" min protection for reinforcing 3. CONCRETE MASONRY UNIT a. shall be meet ASTM C 90-90 GRADE NI OR NII. b. shall be load bearing concrete masonry units. 4. MORTAR a. shall meet ASTM C 270 standards. b. shall be type M. c. joint type shall be concave. 5. GROUT a. shall meet ASTM C 476 standards. b. shall have a min. 2000 psi compressive strength. c. shall meet 8" -10" slump test. (2) #5 VERTS a DOOR SCH 1 FIBERGLASS EXT, D, 2 NONE 3 FRENCH INTERIOR C 4 RELOCATED EXISTIC FULL HEIGHTI PI R WALL SECTIdN #5 HORIZ @ WDO SILL, EMBED 6" INTO EX FILLED CELL EX FILLED CELL, SAME OPP. L------------ --- ----- ---- T-2" �- 2'-10" 36" VERIFY R.O. VERIFY R.O. 2'-4" 9'-0" EXIST OPNG 2'-4" FOUNDATION P LA N SCALE 1/4" = V-0" REMOVE EXISTING OVERHEAD DOOR DEMO PLAN SCALE 1/4" = V-0" Lit. ►_, �I 42nd St. 0 � I SITE PLAN SCALE 1" = 30' PROJECT INFORMATION DESIGN PARAMETERS: 2020 7th Ed. Florida Building Code Building Design: Enclosed Basic Wind Speed: Al160 mph 3 second gust Risk Category: II Internal Pressure Coefficient: +/-0.18 Building Mean Height: 12'-0" Roof Overhang: V-4" Roof Pitch: 5/ 12 OCCUPANCY: R3 One -Family Residence EXISTING CONSTRUCTION: Type V Unprotected, Unsprinklered Ext. brg walls- CMU Eng, wood trusses Int walls -wood stds & drywall Asphalt Shingles AREA TABULATIONS: Existing House: Non -A/C Area: 280 sqft. F-Porch : 60 sf R-Porch : 220 sf New A/C Area: 273 sf Existing A/C Area: 1117 sf Total A/C Area: 1390 sqft Total: 1670 sqft. FLOOR PLAN SCALE 1/4" = V-0" TEP OR 3-1/2" x 25 4TL STUD rITION W/" BD EA SIDE =X CBS WALL HORIZ PT IRRING @ 16"oc. FOIL INSUL &" fP BD OVER, ALL :TERIOR WALLS �a w A - w Ln 00 0= O a w � LU _ U_w 0 � o Z0 00 L—__— +24.3/-32.3 - -+24.3/-32.3 � -- 2.3-------- 4.3-32. --- — #5 HORIZ @SILL FRONT ELEVATION SCALE 1/4" = 1'-0" N h 0 in (n 5 a U a o 3,: O +, Z �CL Q W _ L U� O > Ld > U Cr W a N n N N N + W N to w 0 M O n E U) E li 0I Q C:) ca 0) O 0 oCO V Qw V V > M zo,� M 0 a) 0 0 ti Q CY — ~ E 0 Q M=F— w W ry O� M J J Uai Z) W IL o W_ rUJ V -a� Q N a m < Z I` ' ^ O C:)v N 2 Z W ZLli 0 J Z Q > > 0 W 0- W ILLZz�to LL ~ ui N LU 0 -� 0 0 0 0 o 0 I- U ry J Of LLJ r CL IL CL C/) DSD PROJ. 2110 DRWN. D D DATE 05 /25121 SHEET 1 of 2 v 0 5/8" MIN. STUCCC FINISH EXIST BOND BEAN ' FLEXW RAP' FLAS f STUCCO BAND AROUND OPENING SOLID 2X FRMG, A TO EXIST LINTEL, W/ FLASHING MESH ON M. BARR 1x P.T. WD. SHIM CAULK @ FRAME - CONT. HEAD :I -FOIL INSUL.(R4) 1/2" GYP. BD. 1/4" TC @ 12"oc STAG FIN. WOOD 'ASING 1/2" GYP. BD. w/ 'ZORNER BEAD /4" TAPCON w/ 1-1/2" :MBEDMENT INTO CONC .PACING PER PRODUCT APPROVAL 2X SOLID FRAME HEAD DETAIL SCFLE 3" _ ELECTRICAL NOTES 1. Contractor shall compare the electrical drawings and 11. Load data and calculations were designed based on specifications with drawings from other trades. Contractor information given to Architect at the time of the design. Prior shall report any discrepancies to the Architect. Obtain written to installation of all equipment verify size of equipment and instructions for any necessary changes. panel sizes. 2. Contractor to verify and coordinate utility service with local 12. Electrical system shall be grounded. See Riser utility company. Locate meter and panel as required. Diagram. 3. Install temporary power for construction as required. 13. Outlet boxes shall be pressed steel in dry locations, 4. All electrical work and materials to be installed per NEC, NFPA, cast alloy with threaded hubs in wet and damp local, state, and national code. locations and special enclosures for other classified 5. Location of electrical raceways, switches, panels, locations. equipment, fixtures, etc. shall be adjusted to accommodate 14. Disconnect switches shall be H.P. rated, heavy the work to avoid interferences anticipated and encountered. 1 duty, quick -made, quick break enclosure required 6. Contractor shall verify switch type and locations with owner by exposure. prior to installation. Color of cover plates, switches and 15. Smoke detectors shall be hard wired (110 volt receptacles shall be selected by owner. type) to non-switchable light circuit and shall not be 7. Contractor shall determine the exact route and location of each connected into the load side of a ground fault electrical raceway prior to make-up and assembly. circuit. 8. Outlets and appliances are shown and located on the drawings 16. Smoke detectors shall be located on or near ceiling as accurately as possible. All measurements shall be verified inside and outside each sleeping area. Verify on the project and in all cases the work shall suit the locations of smoke detectors with the drawings. surrounding trim, finishes, and/or construction. 17. Smoke detectors shall be 110 volt type, with a test 9. Heights of all outlets shown on the drawings are button with battery back-up system and visible approximate only. "power on" indicator. 10. All outlets installed outdoors, in bathrooms, on kitchen 18. Carbon Monoxide Detectors are required, may be in combination counters and in the garage shall have ground -fault circuit with Smoke Detector, mounted within 10 ft. of a bedroom. interrupter breaker or receptacle. All other outlets 19. Furnish and install fixtures as called for on the plans or as installed in living spaces shall have an arc -fault circuit selected by Owner. interrupter breaker or receptacles. 20. Contractor shall verify fixture type and locations with owner prior to installation. 21. Coordinate heights of wall mounted lighting fixtures to clear mirriors, cabinets, builts-ins, trim, etc. ARCHITECTURAL SPECIFICATIONS GENERAL SCOPE OF WORK: 1. MATERIALS AND METHODS OF CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF ST. LUCIE COUNTY, FL AND THE FLORIDA RESIDENTIAL BUILDING CODE, 2020 7th EDITION. 2. SCOPE OF WORK INCLUDES: a) REMOVE EXISTING OVERHEAD DOOR. b) INSTALL EMBEDDED REBAR DOWELS AT EXISTING TIE -BEAM AND FOOTING, INSTALL CMU BLOCK CLOSURE WALL W/ REINFORCING. c) FRAME WOOD HEADERS, INSTALL EXTERIOR DOOR AND WINDOW PER PRODUCT APPROVALS & DETAILS. d) FRAME WOOD (OR METAL) STUD PARTITIONS, INSTALL ATTIC & WALL FOIL INSULATION, AC DUCTWORK, ELECTRICAL WIRING, AND SHEET ROCK. e) INSTALL ELECTRICAL FIXTURES, AND SELECTED FLOORING. f) APPLY EXTERIOR STUCCO (FINISH) AND PAINT INTERIOR AND EXTERIOR TO MATCH EXISTING. DIVISION 3 & 4: CONCRETE & MASONRY 1. FOR CBS WALL SEE MASONRY NOTES. DIVISION 6: WOOD AND PLASTICS 1. LUMBER: FURRING & BLOCKING: DOUGLAS FIR -LARCH, HEM -FIR, SOUTHERN PINE, OR SPRUCE -PINE -FIR NO.2 OR BETTER. MAX 19% MOISTURE CONTENT. USE PRESSURE TREATED WHERE NOTED AND/OR REQUIRED AND IDENTIFIED PER FBC 2303.1,8.1. 2. PLYWOOD (where called for): APA EXP-1, CDX. 3. FRAMING ANCHORS: SIMPSON, GALVANIZED, W/ ALL NAILS, SCREWS AS SCHEDULED. 4. ANCHOR ADHESIVE: SIMPSON AT'ACRYLIC-TIE', 2 COMPONENT, CAT. PA. 69. DIVISION 7: THERMAL AND MOISTURE PROTECTION 1. BATT ATTIC INSULATION: EQUAL TO R-30 MANVILLE KRAFT-FACED THERMAL INSULATION: INSTALL PER MANUFACTURER'S RECOMMENDATION FOR THE GIVEN CONDITION. 2. WALL INSULATION: MIN R-4 AT NEW CBS WALL, INSTALL PER MANUFACTURERS RECOMMENDATIONS. 3. CAULKING/SEALANT: GE SILICONE II XST, PAINTABLE TYPE. 4, DOOR & WINDOW MASONRY FLASHING: EQUAL TO 'DRYLOK' BY UNITED GILSONITE LABORATORIES, APPLIED PER MFGR'S RECOMMENDATION. APPLY TO BOTH EXISTING AND NEW MASONRY. 5. FLASHING AT DOOR & WINDOW WOOD HEADERS: EQ TO DUPONT'FLEXWRAP', SELF -ADHERED BUTYL FLASHING PER MANUFACTURE'S RECOMMENDATION. DIVISION 8: WINDOWS AND DOORS 1. EXTERIOR DOORS: P.RE-HUNG, FIBERGLASS OR METAL, IMPACT RATED, FLUSH OR PANEL INSULATED CORE, PRE -FINISHED, 3-BUTT HINGES PER DOOR, 36"x80" SIZE, RAIN -TIGHT WEATHERSTRIPPING AND WEATHERSEAL THRESHOLD. HARDWARE: KEYED EXTERIOR LOCKSET. 2. WINDOWS: SINGLE HUNG, VINYL OR ALUMINUM, IMPACT RATED, INSULATED, SIZES SHOWN, INSTALL PER PRODUCT APPROVAL. DIVISION 9: FINISHES 1. CEMENT STUCCO: - ON PLYWOOD (WHERE NOTED) - WIRE MESH ON 30# MIN FELT UMDERLAYMENT, SCRATCH, BROWN, FINISH COATS, 3/4" THK - ON CONC BLOCK - 1/2" THK, 2 COAT, TEXTURE FINISH TO MATCH EXIST HOUSE. - SOFFIT - ON EXPANDED METAL LATH 2. GYPSUM WALLBOARD SHALL BE U.S. GYPSUM OR EQUAL. INSTALL AS PER MANUFACTURER'S INSTRUCTIONS. MATCH EXIST TEXTURE. 3. PAINT INTERIOR 2 COATS, OF VINYL LATEX SEMI -GLOSS PAINT STUCCO 2 COATS LATEX 4. FLOOR FINISH AS SELECTED, 5. CERAMIC TILE AS SELECTED. DIVISION 15: MECHANICAL 1. EXTEND DUCTWORK OF FXISTING HVAC SYSTEM INTO NEW ADDITION AS SHOWN ON DRAWINGS. ALL WORK SHALL COMPLY WITH THi FLORIDA BUILDING CODE 20120, 7th ED. MECHANICAL. SEE ATTACHED MANUAL-3, ENERGY CALCS AND DUCT LAYOUT W/ CFM. 2. CUTTING & PATCHING OF WALLS OR ROOF SHALL BE IN ACCORDANCE TO THE OWNER'S AND ARCHITECT'S REQUIRMENTS. 3. COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO INSTALLATION TO AVOID ROUTING CONFLICTS. 4. PROPERLY DISPOSE OF ALL DISCARDED MATERIAL AND WASTE PER OWNER AND THE CITY OF FT. PIERCE REQUIREMENTS. Weather Head EXIST SERVICE EXIST 150 AMP Ee METER EXIST #4 COPPER CU TO COLD WATER PIPE AT HOSE BIB GROUND ROD EMBEDDED IN FOUNDATION ELECTRICAL RISER Electrical Load Calculations: SCALE: NTS 1,390 sgft. @ 3.0 VA/sqft. = 4170 VA Garbage Disposal = 900 VA Refrigerator = 1,200 VA Total Panel Load: Microwave = 1,500 VA A/C #1 @ 10.0 kw = 10,000 VA Dishwasher = 1,800 VA 1st 10,000 VA @ 100% = 10,000 VA Range/Oven = 6,000 VA Remaining VA @ 40% = 11,308 VA Dryer = 5,000 VA Washer = 1,200 VA Total: = 31,308 VA Water Heater = 5,000 VA Pump = 1,500 VA 31,308 VA = 130.45 amps A/C #1 @ 10.0 kw = 10,000 VA 24 240 V Total Amps required: = 131 Sub -Total: = 38,270 VA Summary: Existing 150 amp service and breaker panel are properly sized for this additional load. AC NOTES: 1. Contractor shall verify all duct sizes and consult Energy Calculations prior to extending A/C system. 2. Flex Duct shall be insulated flexible duct. ELECTRICAL & AC PLAN SCALE 1/4" = V-0" N N U. O z w 3 U o0 O Z 5 a 3 w -4- O LLI a w U W J Ir W a. 3 a. W N M cn �! (0 n O E W CK ti U O"' rn J VL U Z0 CL WItf- W " 'v C ^/ g LL dN' a N < Z F_ .^ vO 2 Q O N U w F_ z0 Z 213 C-L C/) U U < Z 06 0 0 Q Q F- U rUU // Of LL. N ry U U U LJ W w W U) DSD PROJ. 2110 DRWN. DSD DATE 05 �25 /21 SHEET 2 of 2 � V"A c -0, w OFFICE USE ONLY: DATE FILED: REVISION FEE: PERMIT # �100 -000 RECEIPT # PLANNING & DEVELOPMENT SERVICES k UIKIW= BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 St. Lucie county Permitting "t"P" ;APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: DETAILED DESCRIPTION OF PROJECT REVISIONS: N I t'k 01� ct C.JA0V\C4t 0/c, M-cc V� . mci 9 00 -M, a Vd 'R f- vt I Cady( 5U-)1"I tO VC-e-f F jCkdt V)eCkV'jd00i('(fV0tAj) Ck(Aj CAOIC CONTRACTOR INFORMATION: SATEofFL REG./CERT. #: 13USINES§­N­AME---�-. QUALIFIERS NAME: __SLit ADDRESS: ) on'-7 m, 4 CITY: STATE: } let= PHONE -(DAYTIME): q'71 - OWNER/BUILDER INFORMATION: NAME: -'Samcno ADDRESS: CITY: -�A '� 1 r- ko? STATE: PHONE (DAYTIME: 77, - q -71 - ARCHITECT/ENGINEER INFORMATION: NAME: Mk) Davi k5 ADDRESS:-3(-, ---l(ACXCLUrkl (+. CITY: Mf-%(SGV\ 1 I STATE: PHONE (DAYTIME): --'773 - -979- 3-:3 so SLCCC,. 9123109 ell"s Revised 0613011 REVISION ST. LUCIE CO FAX: '77A - e-OTS 10 -to 1:2 15( 1a " ZIP: -3z4L FAX: '77; - I;q5- (o?) ZIP: FAX: CvKai a(A 0 com