HomeMy WebLinkAboutEnergy Calculation Form & Manual J's (2) FOP,M R405-2014
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative(Performance) Method
Applications for compliance with the 2014 Florida Building Code Ene
rgy Conservation via the
residential Simulated Performance method shall include
rs checklist
Q A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a-ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst-case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report(1 page)and an input summary checklist that can
be used for field verification (usually 4 pages/may be greater).
nergy Performance Level(EPL)Display Card(one page)
13 andatory Requirements(three pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage" then a completed
Form R405 Duct Leakage Test Repot(usually one page)
DISAppROVED
EnergyGauge@-USRCZB v5.1
10/13/2617 10:01:27 AM Page 1 of 1
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: CAL ATLANTIC RIVERBEND LAUREL 5512 Builder Name: CAL ATLANTIC HOMES
Street: Permit Office: PORT ST LUCIE
City,State,Zip: PORT ST LUCIE,FL, Permit Number.
Owner, Jurisdiction: 661200
Design Location: FL,Fort Pierce County:: St. Lucie(Florida Climate Zone 2)
1. New construction or.e)isting New(From Plans) 9. Wall Types(4374.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=9.0 2399.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 1140.00 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Exterior R=19.0 495.00 ft
4. Number of Bedrooms 5 d.other(see details) R= 340.00 ft2
5. Is this a worst case? Yes 10.Ceiling Types (2306.0 sgft,) Insulation, Area
a.Roof Deck(Unvented) R=20.b 2306.00 ft2
6. Conditioned floor area above grade(ft2) 4404 b.NIA R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(710.5 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 142.8
a. U-Factor. Sgl,U=1.05 551.50 ft2 b.Sup: Attic,Ret:Attic,AH:2nd Floor 6 142.8
SHGC: SHGC=0.25
b. U-Factor. Sgl,U=0.77 111.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.22 a.Central Unit 47.0 SEER:14.00
b.Central Unit 47.0 SEER:14.00
c. U-Factor. Sgl,U=1.07 48.00 ftz
SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency
d. U-Factor: WA ft2 a.Electric Heat Pump 44.0 HSPF:8.50
SHGC: b.Electric Heat Pump 44.0 HSPF:8.50
Area Weighted Average Overhang Depth: 4.261 ft.
Area Weighted Average SHGC: 0.249 14.Hot water systems
8, Floor Types (2168.0 sgft.) Insulation Area a.Natural Gas Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 2098.00 ft2 EF:0.600
b. Conservation features
b.Floor over Garage R=19.0 70.00 ft2 None
c.NIA R= ft2 15.Credits Pstat
Total Proposed Modified Loads: 128.13 PASS
SS
Glass/Floor Area: 0.161 Total Baseline Loads: 133.71 !�1
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this 0
Code. calculation indicates compliance h, '' , ,��<�a<
with the Florida Energy Code. ti �4tri' ''• y. ,` o
PREPARED BY: Before construction is completed
DATE: - this building will be inspected for k;f
compliance with Section 553.908 * •
I hereby certify that this building,as gn i 'r►comp ian Florida Statutes.
with the Florida Energy o e.
OWNER/AGEN : BUILDING OFFICIAL:
DATE: 1 L / DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualities as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1,2017
this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50(R402.4.1.2).
1 0/13/2017 1 0:01 AM EnergyGaugeO USA-v5.1-Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
Tdle: CAL ATLANTIC RIVERBEND Bedrooms: 5 Address Type: Lot Information
Building Type: User Conditioned Area: 4404 Lot#
Owner. Total Stories: 2 Block/SubDMsion: RIVERBEND
#of Units: 1 Worst Case; Yes PlatBook:
Builder Name: CAL ATLANTIC HOMES Rotate Angle: 225 Street:
Permit Office: PORT ST LUCIE Cross Ventilation: County: St.Lucie
Jurisdiction: 661200 Whole House Fan: City,State,Zip: PORT ST LUCIE,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Blockl 2098 20980
2 Block2 2306 20754
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 1st Floor 2098 20980 Yes 8 1 1 Yes Yes Yes
2 2nd Floor 2306 20754 No 8 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio 1st Floor 207 ft 0 2098 ft2 — 0 0 1
2 Floor over Garage 2nd Floor -- -w 70 ft2 19 0 0 1
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Barrel tile 2498 ft2 0 ft2 Light 0.96 No 0.9 No 20 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Unvented 0 2306 ft2 N Y
10/13/201710:01 AM EnergyGaugeO USA-v5.1-Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Unvented) 2nd Floor 0.1 Blown 2306 ft2 0.11 Wood
WALLS
Adjacent Spate Cavity Width Height Sheathing Framing Solar Below
1 N=>SW Exterior Concrete Block-Int Insul 1st Floor 9 52 10 520.0 ft2 0 0.35 0
2 E=>NW Exterior Concrete Block-Int Insul 1 st Floor 9 49 10 490.0 ft2 0 0.35 0
_3 S=>NE Exterior Concrete Block-Int Insul 1 st Floor 9 30 10 300.0 ft2 0 0.35 0
-4 W=>SE Exterior Concrete Block-Int Insul 1st Floor 4.1 60 10 600.0 ft2 0 0.36 0
5 S=>NE Garage Frame-Wood 1 st Floor 11 22 10 220.0 ft2 0 0.35 0
-6 E=>NW Garage Frame-Wood 1 st Floor 11 12 10 120.0 ft2 0 0.35 0
7 N=>SW Exterior Concrete Block-Int Insul2nd Floor 9 31 9 279.0 ft2 0 0.35 0
- 8 E=>NW Exterior Concrete Block-Int Insul2nd Floor 9 50 9 450.0 ft2 0 0.35 0
9 S=>NE Exterior Concrete Block-Int Insul2nd Floor 9 40 9 360.0 ft2 0 0.35 0
_10 W=>SE Exterior Concrete Block-Int Insul2nd Floor 4.1 60 9 540.0 ft2 0 0.35 0
_11 S=>NE Exterior Frame-Wood 2nd Floor 19 23 9 207.0 ft2 0 0.35 0
12 E=>NW Exterior Frame-Wood 2nd Floor 19 11 9 99.0 ft2 0 0.35 0
13 N=>SW Exterior Frame-Wood 2nd Floor 19 21 9 189.0 ft2 0 0.35 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 E=>NW Insulated 2nd Floor None .46 6 8 48 ft2
2 S=>NE Wood 1st Floor None .46 2 8 8 21.3 ft2
3 E=>NW Wood 2nd Floor None .46 2 8 8 21.3 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/ Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N=>SW 1 Metal Single(Tinted) Yes 1.06 0.25 78,0 ft2 1 ft 6 in 12 ft 0 in None Exterior 5
2 N=>SW 1 Metal Single(Tinted) Yes 0.77 0.22 96.0 ft2 11 ft 6 in 0 ft 6 in None Exterior 5
3 W=>SE 4 Metal Single(Tnted) Yes 1.05 0.25 24.0 ft2 22 ft 6 in 2 ft 0 in None Exterior 5
4 N=>SW 1 Metal Single(Tinted) Yes 1.05 0.25 8.0 ft2 1 ft 6 in 12 ft 0 in None Exterior 5
5 E=>NW 2 Metal Single(Tinted) Yes 0.77 0.22 15.0 ft2 1 ft 6 in 12 ft 0 in None Exterior 5
6 E=>NW 2 Metal Single(Tinted) Yes 1.05 0.25 8.0 ft2 1 ft 6 in 12 ft 0 in None Exterior 5
7 S=>NE 3 Metal Single(Tinted) Yes 1.05 0.25 48.0 ft2 7 ft 6 in 1 ft 0 in None Exterior 5
8 E=>NW 2 Metal Single(Tinted) Yes 1.05 0.25 15.0 ft2 1 ft 6 in 12 ft 0 In None Exterior 5
9 W=>SE 4 Metal Single(Tinted) Yes 1.05 0.25 60.0 ft2 1 ft 6 in 12 ft 0 in None Exterior 5
10 N=>SW 7 Metal Single(Tinted) Yes 1.05 0.25 24.0 ft2 1 ft 6 in 12 ft 0 in None Exterior 5
11 N=>SW 7 Metal Single(Tinted) Yes 1.05 0.25 60.0 ft2 1 ft 6 in 1 ft 0 in None Exterior 5
12 W=>SE 10 Metal Single(Tinted) Yes 1.07 0.3 12.0 ft2 19 ft 0 in 1 ft 6 in None Exterior 5
13 N=>SW 13 Metal Single(Tinted) Yes 1.07 0.3 36.0 ft2 1 ft 6 in 1 ft 0 in None Exterior 5
14 N=>SW 7 Metal Single(Tinted) Yes 1.05 0.25 22.5 ft2 1 ft 6 in 1 ft 0 in None Exterior 5
15 E=>NW 8 Metal Single(Tinted) Yes 1.05 0.25 24.0 ft' 1 ft 61n 1 ft 0 in None Exterior 5
10/131201710:01 AM EnergyGaugeO USA-v5.1 -Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case_
Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
16 E=>NW 8 Metal Single(Tinted) Yes 1.05 0.25 12.0 ft2 1 ft 6 in 1 ft 0 in None Exterior 5
17 S=>NE 9 Metal Single(Tinted) Yes 1.05 0.25 24.0 ft2 1 ft 6 in 3 ft 0 in None Exterior 5
18 E=>NW 12 Metal Single(Tinted) Yes 1.05 0.25 15.0 ft2 1 ft 6 in 1 ft 0 in None Exterior 5
19 S=>NE 9 Metal Single(Tinted) Yes 1.05 0.25 15.0 ft2 1 ft 6 in 1 ft 0 in None Exterior 5
20 E=>NW 8 Metal Single(Tinted) Yes 1.05 0.25 8.0 ft2 1 ft 6 in 1 ft 0 in None Exterior 5
21 S=>NE 9 Metal Single(Tinted) Yes 1.05 0.25 8.0 ft' 1 ft 6 in 1 ft 0 in None Exterior 5
22 S=>NE 9 Metal Single(Tinted) Yes 1.05 0.25 18.0 ftz 1 ft 6 in 3 ft 0 in None Exterior 5
23 W=>SE 10 Metal Single(Tinted) Yes 1.05 0.25 60.01? 1 ft 6 in 1 ft 0 in None Exterior 5
24 W=>SE 10 Metal Single(Tinted) Yes 1.05 0.25 20.0 ft2 1 ft 6 in 1 ft 0 in None Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 620 ft2 620 ft' 64 ft loft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000421 4869 267.3 502.7 .3788 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8.5 44 kBtu/hr 1 sys#1
2 Electric Heat Pump None HSPF:8.5 44 kBtu/hr 2 sys#2
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit None SEER:14 47 kBtu/hr 1410 cfm 0.75 1 sys#1
2 Central Unit None SEER:14 47 kBtu/hr 1410 cfm 0.75 2 sys#2
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Natural Gas None Exterior 0.6 50 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
9
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None fJ2
10/13/2017 10:01 AM EnergyGauge@ USA-v5.1 -Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
DUCTS
--Supply— —Return— Air CFM 25 CFM25 HVAC#
# Location R Value Area Location Area Leakage Type Handier TOT OUT QN RLF Heat Cool
1 Attic 6 142.8 ft Attic 45.7 W Default Leakage 2nd Floor (Default) (Default) 1 1
2 Attic 6 142.8 ft Attic 45.7 ft2 Default Leakage 2nd Floor (Default) (Default) 2 2
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar Apr May Jun Jul Au Se Oct kj Nov Dec
Heatin Jan Feb Mar Apr L May Jun Jul Aug Sep Oct Nov Dec
Ventin Jan Feb Mar A r [ Ma Jun Jul Au Se Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68' 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 -68 68 68 68 68 68 66 66
MECHANICAL VENTILATION
Type Supply CFM Exhaust CFM Fan Watts HRV Heating System , Run Time Cooling System
None 0 0 0 0 1 -Electric Heat Pump 0% 1 -Central Unit
None 0 0 0 2-Electric Heat Pump 0% 2-Central Unit
10/13/201710:01 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 5 of 5
FORM R405 2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index,the more efficient the home.
PORT ST LUCIE, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int lnsul,Exterior R=9.0 2399.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 1140.00 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Exterior R=19.0 495.00 ft2
4. Number of Bedrooms 5 d.other(see details) R= 340.00 ft2
5. Is this a worst case? Yes 10.Ceiling Types Insulation Area
a.Roof Deck(Unvented) R=20.0 2306.00 ft2
6. Conditioned floor area(ft2) 4404 b.N/A R= ft2
7. Windows" Description Area c.N/A R= ft2
a. U-Factor: SgI,U=1.05 551.50 ft2 11.Ducts R ft2
a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 142.8
SHGC: SHGC=0.25 b.Sup: Attic, Rat Attic,AH:2nd Floor 6 142.8
b. U-Factor. Sgl,U=0.77 111.00 ft2
SHGC: SHGC=0.22 12.Cooling systems kBtu/hr Efficiency
c. U-Factor. SgI,U=1.07 48.00 ft2 a.Central Unit 47.0 SEER:14•00
SHGC: SHGC=0.30 b.Central Unit 47.0 SEER:14.00
d. U-Factor. N/A ft2 13.Heating systems kBtu/hr. Efficiency
SHGC: a.Electric Heat Pump 44.0 HSPF:8.50
Area Weighted Average Overhang Depth: 4.261 ft. b.Electric Heat Pump 44.0 HSPF:8.50
Area Weighted Average SHGC: 0.249
8. Floor Types Insulation Area 14.Hot water systems
z a.Natural Gas Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 2098.00 ft EF:0.6
b.Floor over Garage R=19.0 70.00 ft2 c.NIA R= ft2 b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded) o� TEsrgrr
0�
in this home before final inspection. Otherwise, a new EPL Display Card will be completed �,''���
based on installed Code compliant features.
Builder Signature: �jQ� Date:
Address of New Home: 13(ga Lo �A��, -an L City/FL Zip:`�7�l
31-111
WE
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
10/13/2017 10:01 AM EnergyGauge®USA-v5.1- Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
Florida Department of Business and Professional Kegulations
Residential Whole Building Performance and Prescriptive Methods
ADDRESS: Permit Number:
7
PORT ST LUCIE, FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
13 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
[Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C.
R402A Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4.
O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air
changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section
553.993(5)or(7),Florida Statutes or individulas licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party. A
written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be
performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed.and sealed;
S.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
O R402A.2 Fireplaces. New wood-buming fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 b an accredited Independent laboratory n I'
Y � P and listed and labeled b the manufacturer.
ry y e
Exception: Site-built windows,skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed In the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces,All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be'sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
13 R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
O R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
0 R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction
or rough-in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553.993(5)or(7),
Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i),Florida Statutes,to be"substantially leak free"by either of
the following:
1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All
register boots shall be taped or otherwise sealed during the test.
2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be
taped or otherwise sealed during the test.If the air handler is not Installed at the time of the test,total leakage shall be less than or equal to 3 cfm
(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code.
10/13/2017 10:01 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 3
FORM R405 2014
MANDATORY REQUIREMENTS - (Continued)
❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41`C)
or below 55°F(13°C)shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'/z inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
❑ R403.4.4 Water heater efficiencies(Mandatory).
O R403.4.4.1 Storage water heater temperature controls
• R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum
temperature setting range shall be from 100'F to 1407(38°C to 60'C).
• R403.4.4.1.2 Shutdown. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s)
of combustion types of service water heating systems to be turned off.
O R403A.4.2 Water heating equipment Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water
heating systems should meet the following criteria:
1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
p R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
• R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
10/13/2017 10:01 AM EnergyGauge®USA-v5.1 - -Section R405.4.1 Compliant Software Page 2 of 3
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and
shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This
selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and mufti-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that toad.
2. When signed and sealed by a Florida-registered engineer,in attached single-and mufti-family units,the capacity of
equipment may be sized in accordance with good design practice.
O R403.6.1.2 Heating equipment capacity
• R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
• R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1.
• R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1.
O R403.6.1.3 Extra capacity required forspecial occasions. Residences requiring excess cooling
or heating equipment capacity on an
Intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or healing within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
p R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55•F,and no precipitation is failing
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40'F.
D 403 9 R Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and
In ground s g ourtd spas shall be as specified in Sections R403.9.1 through R403.9,3 and In accordance with ANSI/APSP-15.The energy
requirements for portable spas shall be In accordance with ANSUAPSP-
14.
O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI 2 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. 'rime switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
• 1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps.
O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have sufficent space,R-10 is allowed.
10/13/201710:01 AM EnergyGaugeO USA-v5.1 - -Section R405.4.1 Compliant Software Page 3 of 3
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND iNSULATION INSPECTION COMPONENT CRITERIA
Project Name: CAL ATLANTIC RIVERBEND LAUREL 5512 Builder Name: CAL ATLANTIC HOMES
Street: Permit Office: PORT ST LUCIE
City,State,Zip: PORT ST LUCIE,FL, Permit Number.
Owner: Jurisdiction: 661200
Design Location: FL,Fort Pierce
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier_
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
airtight, IC rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
1 0/1 312017 1 0:01 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 1 of 1
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: CAL ATLANTIC RIVERBEND LAUREL 5512 Builder Name: CAL ATLANTIC HOMES
Street: Permit Office: PORT ST LUCIE
City,State,Zip: PORT ST LUCIE,FL, Permit Number:
Design Location: FL,Fort Pierce Jurisdiction: 661200
Cond.Floor Area:: 4404 sq.ft. Cond.Volume: 41734 cu ft.
Envelope Leakage Test Results Leakage Characteristics
Regression Data: CFM(50):
ELA:
Single or Multi Point Test Data
HOUSE PRESSURE FLOW: EgLA.
1 Pa cfm ACH:
2 Pa cfm SLA:
3 Pa cfm ACH(50)
4 Pa cfm For prescriptive projects, tested leakage must be
5 Pa cfm <=7 ACH(50). For performance projects,tested
6 Pa cfm leakage must be<=the ACH(50)shown on Form
R405-2014 for this project.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour
in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by
either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing
shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other
infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not seated beyond intended infiltration
Control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
Testing shall be conducted by either
I hereby certify that the above envelope leakage individuals as defined in Section 01
0'1-114E �
performance results demonstrate compliance s'
553.993(5)or(7), Florida Statutes or �., �0 +
with Florida Energy Code requirements in individuals licensed as set forth in �' �`" '.0
accordance with Section R402.4.1.2. Are. %=F.;,.� t
Section 459.105 3 y"
( }(f), (g),or(i)or an
approved third party. A written report
SIGNATURE: of the results of the test shall be signed _
by the third party conducting the test
PRINTED NAME:
and provided to the code official.
DATE: BUILDING OFFICIAL:
DATE:
10/13/2017 10:01 AM EnergyGaugeO USA-v5.1 -section R405.4.1 Compliant Software Page 1 of 1
Cal Atlantic 5512 Model Laurel
HVAC Load Calculations
for
Cal Atlantic Homes
rxHVAC. HVAC. LoAce
Prepared By:
Robert Weidman
Preferred Air Conditioning&Mechanical
1643 Donna Road
West Palm Beach,FI.33409
661 8691093
Friday, October 13,2017
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
Rhvac'-Residential`&Li9 ht Col im l:HVAC Loads•:;tdia _'
.:.,_ ......:.:. Elite:°SoftwareDevelopmerrt Inc:
Preferred:Alr:Cond1ttonm &Nie.ch... :::::;:: <:;::>: .:;::; ::.•;::: ?,;,:: 1::-:.::;; :::::;
5...-:,.:. _ CaI Atlantic 5512:Model:LaUrel:
West Palm 3each FL.33408 ..
a e•2
Project Report
Project Title: Cal Atlantic 5512 Model Laurel
Designed By: Preferred Air Conditioning &Mechanical
Project Date: 10-12-2017
Client Name: Cal Atlantic Homes
{ Company Name: Preferred Air Conditioning&Mechanical
Company Representative: Robert Weidman
Company Address: 1643 Donna Road
Company City: West Palm Beach, A. 33409
Company Phone: 561 8691093
Company Fax:
Company E-Mail Address: getcold.net
Company Comment:
Reference City: Fort Pierce, Florida
Building Orientation: Front door faces North
Daily Temperature Range: Medium
Latitude: 27 Degrees
Elevation: 25 ft.
Altitude Factor. 0.999
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 42 39.4 n/a n/a 72 n/a
Summer. 90 78 59% 50% 75 61
Total Building Supply CFM: 2,520 CFM Per Square ft.: 0.609
Square ft. of Room Area: 4,139 Square ft. Per Ton: 536
Volume(ft3): 39,118
......—...._..,....�._...:..._s..... .: •............. r.L'Bu dln Dads ..... .
Total Heating Required Including Ventilation Air: 73,218 Btuh 73.218 MBH
Total Sensible Gain: 65,609 Btuh 71 %
Total Latent Gain: 26,992 Btuh 29 %
Total Cooling Required Including Ventilation Air: 92,601 Btuh 7.72 Tons(Based On Sensible+ Latent)
-
................•.... li.... .....,... ::!..,.....III.,....r,... .... ..,....._ .....i....... ..1.. ..Y..
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
CA...\CAL ATL RIVERBEND LAUREL 5512.rh9 Friday, October 13,2017, 9:58 AM
Rhp4c-RfsidenUall�.1.ghtCommercialllYAG;goads..,::,::':'.;:'_-; : :: .... .:::: Eaitesoftvvar :�
PneferredAtrCondibanln &Mech: _.;:;: s.;"..::.>::,:: :';:4; ::•:.::::::.: :_::..::.:,::.;•. .. .:.... ..,
...evelopment,'Inc::
::.'• -
• •�'Gat Atlantic 55`12;Modei Laurel
Wi:st Pa1m�B ;.:3 Og.. ... .. ..:..
each FL. 34 .:..:.. ;
Pa e•3
System 1 First Floor Summary Loads
.. iAt..._....., .. . .n ....t .. ............. 1...w..:. .
...,.,:.,........ .. .z._..,...,., <. .._. ., .fir_i.._.. _. a ,..._...._s....l.._.... %?.:
e n... -
.....__....r...,v�...........:.,... :.............._. ._.....,. .,..... GtWatf.. doss. :Ga':
vain
STPC SHG: Glazing-STANDARD PACIFIC HOMES 208 6,679 0 7,400 7,400
SINGLE HUNG WINDOW, u-value 1.07, SHGC 0.3
STPC FD: Glazing-STANDARD PACIFIC HOMES 72 2,203 0 1,496 1,496
FRENCH DOOR, u-value 1.02, SHGC 0.26
STPC SGD: Glazing-STANDARD PACIFIC HOMES 96 3,197 0 2,144 2,144
SLIDING GLASS DOOR, u-value 1.11, SHGC 0.27
11 D: Door-Wood-Solid Core 21 246 0 213 213
11F: Door-Wood-Solid Core With Metal Storm 21 176 0 153 153
STUCCO BLOCK R-4.1:Wall-Custom, BLOCK 4.1 1273 4,547 0 2,014 2,014
12B-Obw:Wall-Frame, R-11 insulation in 2 x 4 stud 409 1,190 0 505 505
cavity, no board insulation, brick finish,wood studs
22A-ph: Floor-Slab on grade, No edge insulation, no 210 8,556 0 0 0
insulation below floor, any floor cover, passive, heavy
oist soil
Subtotals for structure: 26,794 _ 0 '13,925 _ 13,925
People: 8 1,840 2,400 4,240
Equipment: 358 5,002 5,360
Lighting: 675 2,302 2,302
Ductwork: 4,303 1,101 3,934 5,035
Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0
Ventilation: Winter CFM:250, Summer CFM:250 8,243 10,376 4,121 14,497
_AED Excursion: 0 0 582 582_
System 1 First Floor Load Totals: 39,339 13,675 32,266 _ 45,941
Supply CFM: 1,236 CFM Per Square ft.: 0.662
Square ft. of Room Area: 1,867 Square ft. Per Ton: 488
Volume(f?): 18,670
Total Heating Required Including Ventilation Air: 39,339 Btuh 39.339 MBH
Total Sensible Gain: 32,266 Btuh 70 %
Total Latent Gain: 13,675 Btuh 30 %
Total Cooling Required Including Ventilation Air: 45,941 Btuh 3.83 Tons(Based On Sensible+ Latent)
Notes..._ .. . . .. r .:.. .._ ......._.......,.r... . .. „ ..,...,_.........:.,..,.r ..... .,, , . . ,
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
f
C:1...1CAL ATL RIVERBEND LAUREL 5512.rh9 Friday, October 13, 2017, 9:58 AM
"ac'- Lh#Co
9m'Residential& "
imerCral. At.:�oads:'> :.:;A:;:::: •:::....:::::::.::: :::Eli.. . .........:.�:..:. ._.,.. :.:;:::.::-..:�,.:::.•:......_.. to S
Preferred Arr Gortditionm &�Me�h.•:...... ....:...:.: :_:•:_.:...... ofiiniare:.Deyelopment,°:lnc.�
. .. c
,:.: ..._. . :. ..... ...:..... ..:_....:::.:::::: ::�;:.•:::�;::;:: :::�;.:.�: '�•��'.::::.;:::�:�:Gal Atlarfti :5fia2:Model�Laure{
West'Pafm'Beach'.:F1 33 69*.--.: :::: ...::r:- :.:..:•'•:::-::: ;.;.:..•:: :•:-:-... •.
Equipment Data - System I - First Floor
Cooling
System Type: Air Source Heat Pump
Outdoor Model: CH14NB048*0**A*
Indoor Model: FB4CNP061 L
Tradename: CARRIER AIR CONDITIONING
Outdoor Manufacturer: CARRIER AIR CONDITIONING
Description: Air Source Heat Pump
AHRI Reference No.: 9162971
Capacity: 47000
Efficiency: 14.5 SEER
Heating
System Type: Air Source Heat Pump
Model: CH 14NB048*0**A*
Tradename: CARRIER AIR CONDITIONING
Manufacturer: CARRIER AIR CONDITIONING
Description: Air Source Heat Pump
Capacity: 44000
Efficiency: 8.5 HSPF
C:\...\CAL ATL RWERBEND LAUREL 5512.rh9 Friday, October 13, 2017, 9:58 AM
:9 'h.f-C•:o..im.:.n..r:e::::r.::c_ ::H.::U.:.:AC...'t.: ad..'s: °;:_�*':-:::::•;';:.:.:..:.::°::,:..; .,.-: :.,;:.;%.:':::::•:::.::::::::<::.:::::::,:°::...::;::••:.:..::::.:::::::::,:_°::;::'.:_:;:::.:::::::,:,::;,::...:.:,:.:,::.
tware•Devefa men IncPreerreRvac-RAtrCde
WestPalm�6eacti.FL'.S3�U9•:.',':::::::.••::•.-;;.�:::,•,�: ::;:.:�:..::;::'::::::::.::.:•,°�;:�•�• ;:;.....: ...;.,.. :•.�:::.. .... ..,:.. •.':::• ::;'..... .,:::::::: .. ••.��5'12NlodelLayrel
:.Pa e 7
S stem 9 Room Load Summary.
_....-. -
Pict'
-
--Zone 1-
1 Family 324 7,500 97 2-7 529 6,211 460 283 283
2 Dining 252 2,221 29 1-7 482 2,830 460 129 129
3 Office 216 5,048 66 1-9 558 5,414 460 246 246
4 Foyer 170 2,378 31 1-5 479 1,436 0 65 65
5 Pantry 44 1,047 14 1-2 590 283 0 13 13
6 Casual Dining/ 441 4,878 63 2-6 485 4,186 358 190 190
Kitchen
7 Bath 4 78 3,217 42 1-4 664 1,274 0 58 58
8 Wic 5 65 617 8 1-2 470 226 0 10 10
9 Bedroom 5 169 1,641 21 1-8 452 3,467 460 158 158
10 Launch 36 535 7 1-3 342 369 0 17 17
11 Laund-r�r- 72 1,819 24 1-5 488 1,461 0 66 66
Ventilation _ 8,243 4,121 10,376
Duct Latent 742
Return Duct 196 988 359
_ y System 1 total _T 1,867 39,339 402 _ 32,266^ 13,675 _ 1,236 1.236
System 1 Main Trunk Size: 12x17 in.
Velocity: 872 ft./min
Loss per 100 ft.: 0.109 in.wg
C0o7m ..5.St TnSO' � - -e mm -
............ ::.. .. ...... ..-.... :,r.;;.,::.::,:: -,
........................:........:.........:........... :.......� . :.... t...._.._...:.....:...,...: �e sible..:...,..__:._._,..:.,,.:........
.. .. .. .: ...... etaf
TX
uh'
Net Required: 3.83 70%/30% 32,266 13,675 45,941
Actual: 3.92 75%/25% 35,250 11,750 47,000
� a the .Data......:.............:....:..........,.:....._...... :..., .._J.,:•. ..,. ,..,-�:_.�:><::.:,.;�:;;:>:::;.:,:
Heating System Cooling System
Type: Air Source Heat Pump Air Source Heat Pump
Model: CH14NB048*0**A* CH14NB048*0**A*
Indoor Model: FB4CNP061 L
Brand: CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING
Description: Air Source Heat Pump Air Source Heat Pump
Efficiency: 8.5 HSPF 14.5 SEER
Sound: 0 0
Capacity: 44,000 Btuh 47,000 Btuh
Sensible Capacity: n/a 35,250 Btuh
Latent Capacity: n/a 11,750 Btuh
AHRI Reference No.: n/a 9162971
C:1...\CAL ATL RIVERBEND LAUREL 5512.rh9 Friday, October 13, 2017, 9:58 AM
Rhvac'-Residential
:. '.:..Elrbe.Sofiware'.Developinerit,lnc.:
Preferred Air Condihoniri ::&Mech:':'::>.::::' : ;:°_'::::::.::;:-•:•..:...:.:..:.....:.:.:.: --.:...::.:..::: :.... ...... . .,.i
:-
Cal.Atlarrtrc 55'IZModei'Laurel'.
:West Palm Beach .1=L:'33409;::':=:; ::.';: :• ::::.:::;:':.: :•:::':;: ;.:.:•::
S stem 2 Second Floor Summ' ary Loads
:_... - h
e
V
.•..,..m..........:_....,.,,�ti 17. ...r..._..:�..,.:t,..,:LQs�........ .:....{T al IR
STPC SHG: Glazing-STANDARD PACIFIC HOMES 319.5 10,259 0,,...•,.,r.:..'.•'9 935 935
SINGLE HUNG WINDOW, u-value 1.07, SHGC 0.3
STPC FIX:Glazing-STANDARD PACIFIC FIXED 20 594 0 907 907
GLASS, u-value 0.99, SHGC 0.33
11 F: Door-Wood-Solid Core With Metal Storm 21 176 0 153 153
STUCCO BLOCK R-4.1:Wall-Custom, BLOCK4.1 1354.5 4,837 0 2,142 2,142
12E-Obw:Wall-Frame, R-19 insulation in 2 x 6 stud 372 759 0 288 288
cavity, no board insulation, brick finish, wood studs
18C1-13o: Roof/Ceiling-Roof Joists Between Roof Deck 2236 4,629 0 3,702 3,702
and Ceiling or Foam Encapsulated Roof Joists,
Spray Foam Insulation,White or Light Color Tile,
Slate or Concrete,White Metal, White Membrane, R-
13 open cell 1/2 lb.spray foam, 3.5 inches in 2 x 4
joist cavity, 1 inch on joist
20P-19: Floor-Over open crawl space or garage, Passive, 60 90 0 30 30
_ R-19 blanket insulation, any cover
Subtotals for structure: 21,344 0 17,157 17,157
People: 8 1,840 2,400 4,240
Equipment: 0 5,011 5,011
Lighting: 0 0 0
Ductwork: 4,292 1,100 3,932 5,032
Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0
Ventilation: Winter CFM: 250, Summer CFM: 250 8,243 10,376 4,121 14,497
AED Excursion: 0 0 _ 723 _7_23
System 2 Second Floor Load Totals: 33,878 13,316 33,344 46,660
CheckFr res.:..... ......... .. .... .. >. .. .....:.:t.t_�.......,............. .........,..-.._ ,t..�. :.... ....._.._... ......-=°
Supply CFM: 1,285 CFM Per Square ft..- 0.565
Square ft. of Room Area: 2,272 Square ft. Per Ton: 584
Volume(f?): 20,448
:
S stern f_o d :.::::.....:.
Total Heating Required Including Ventilation Air. 33,878 Btuh 33.878 MBH
Total Sensible Gain: 33,344 Btuh 71 %
Total Latent Gain: 13,316 Btuh 29 %
Total Cooling Required Including Ventilation Air. 46,660 Btuh 3.89 Tons(Based On Sensible+ Latent)
-.. .. ... .. ...............................:..... _ ..✓,. .
.:...,:......,, ... ,. .......,, ...E.......:.........:.....�...,..: ....., .., ..:,......,....
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
1
C:`...1CAL ATL RIVERBEND LAUREL 5512.rh9 Friday, October 13, 2017, 9:58 AM
Residefitial&.icigFrtCoiitrr+ercial'HVA :�aads
::.:_ .: _•.:..:::.::::_:: :::..:.:....... ::;:::::<:;:::.:-.- ...... :::,.:;•;Elite:Soffware:Deyelopme4;Irtc:
PreferredAir.�orttlit�onrn &-Mectr::,: ;:: :>• r:.: :.. ..:.. ._:..: ._.::..:. . ..... ... .:._.. ,..
:: ..9._.... . �:••..:::
:.:... ... .
West Palm:Beach :FL�33449�:�-;��::��.;:::.:..:,:..>::::�;•:�.-:.:•:::•:•: .......:.:.:.:•:::.; ...:. .....,:.•:�.�:;:�:,•;.:.�-...::-;•...:,::�..;:::;.-:::;;:.:..;.Aflantic55'1.2Nfod eI:Laiiref
Equipment Data - System 2 - Second Floor
Cooling
System Type: Air Source Heat Pump
Outdoor Model: CH14NB048*0**A*
Indoor Model: FB4CNP061 L
Tradename: CARRIER AIR CONDITIONING
Outdoor Manufacturer. CARRIER AIR CONDITIONING
Description: Air Source Heat Pump
AHRI Reference No.: 9162971
Capacity: 47000
Efficiency: 14.5 SEER
Heating
System Type: Air Source Heat Pump
Model: CH14NB048*0**A*
Tradename: CARRIER AIR CONDITIONING
Manufacturer: CARRIER AIR CONDITIONING
Description: Air Source Heat Pump
Capacity: 44000
Efficiency: 8.5 HSPF
C:1...\CAL ATL RIVERBEND LAUREL 5512.rh9 Friday, October 13, 2017, 9:58 AM
Rhvac;-:Residantia[
eyelopment,.lnc::
.
Freferfed Alr:Cortdit<onin :''`''- ::::-:::::::::. : . ::....•.: .
tic 5$1 2.Mod6iLau rel
WeS0• ilm:.Beach"'F..L:334f19::.:::: ...:: .::';::
- Pa'e''8
S stern 2 Room Load Summary
{ rlt
-
.3:
�........... __.,..., ... ...v. .�+�y �>
-
`SP
a..
.r
--Zone 2--
12 Bonus Room 342 5,207 68 2-7 491 5,765 0 262 262
13 Stairwell 152 1,305 17 1-5 476 1,426 0 65 65
14 Loft 209 1,753 23 1-5 579 1,734 0 79 79
15 Bedroom 2 216 2,819 37 1-7 584 3,433 460 156 156
16 Bath 2 90 1,417 18 1-4 535 1,026 0 47 47
17 Bedroom 3 198 2,262 29 1-7 551 3,235 460 147 147
18 Bath 3 99 728 9 1-3 426 460 0 21 21
19 Bedroom 4 210 2,409 31 1-7 547 3,215 460 146 146
20 Master Wic 144 700 9 1-3 390 421 0 19 19
21 Master Bath 252 3,429 45 2-4 703 2,696 0 123 123
22 Master Bedroom 360 3,410 44 1-9 497 4,825 460 _219 219_
Ventilation 8,243 4,121� 10,376 �W
Duct Latent 741
Return Duct 195 _ 987 359
T System 2 total 2,272 33,878 331 33,344 13,316 1,285 1,285 1
System 2 Main Trunk Size: 12x18 in.
Velocity: 856 ft./min
Loss per 100 ft.: 0.103 in.wg
00 In
.r_..
�rn Sum
._....::........._..:.,.:..:::.....:.... ..._...,.�.......::....:......... ...ayta.....:. �. .�..:�,., c13:1
C ohn W.
., . .. ..._..._...... ., . ,. .. 9 ........................ ,...... .........,.. . .{_, ::i=ate
�T
r.
Net Required: 3.89 71%/29% 33,344 13,316 46,660
Actual: 3.92 75%/25% 35,250 11,750 47,000
ui ment'r]�ta.: ... . .. ...., , �..,._r ......... ......,,,....�....... . . ._.. . .. -
...............
...........::......:..
Heating System Cooling System
Type: Air Source Heat Pump Air Source Heat Pump
Model: CH14NB048*0**A* CH14NB048*0**A*
Indoor Model: FB4CNP061 L
Brand: CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING
Description: Air Source Heat Pump Air Source Heat Pump
Efficiency: 8.5 HSPF 14.5 SEER
Sound: 0 0
Capacity: 44,000 Btuh 47,000 Btuh
Sensible Capacity: n/a 35,250 Btuh
Latent Capacity: n/a 11,750 Btuh
AHRI Reference No.: n/a 9162971
C:1...\CAL ATL RIVERBEND LAUREL 5512.rh9 Friday, October 13,2017, 9:58 AM