HomeMy WebLinkAboutCompaction Test Soil Nuclear Gauge Client: Project:
Report Date: 7/13/2018 Standard Pacific Homes,South Florida 13-0183.00
Test Method:ASTM D 6938 825 Coral Ridge Drive Riverbend
Port St.Lucie Coral Springs, FL 33071-4180 St. Lucie County, Florida
FBPE CA#4930
607 NW Commodity Cove
Port St.Lucie,FL 34986
Phone:772-924-3575 1 Fax:772-924-3580
Test Results
Optimum Maximum In Place In Place Probe Min/Max
Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Comp.
Test# Of Date Proctor ID Method Classification N (pcf) N (pcf) (in) Compaction N Remark
132 7/12/18 P-1 N/A 10.2 116.0 9.2 114.3 12 99 95/105 Pass
133 7/12/18 P-1 N/A 10.2 116.0 9.8 113.8 12 98 95/105 Pass
134 7/12/18 P-1 N/A 10.2 116.0 9.5 114.7 12 99 95/105 Pass
Test Information
Gauge
Test# Test Location Elevation Reference Make I Model I SN I Calibrated Field Technician
132 Pad:Northeast corner of pad for lot 3. 0-1 Troxler/T3430/22260/ Greatorex,Brandon
133 Pad:Center of pad for lot 3. 0-1 Troxler/T3430/22260/ Greatorex,Brandon
134 Pad:Southwest corner of pad for lot 3. 0-1 Troxler/T3430/22260/ Greatorex,Brandon
Remarks Comments
Pass:Tests results comply with specifications Tests are"Direct Transmission"(Method A)unless probe depth is noted as
"Backscatter".Gauge calibration data on file with the testing agency.
REICEIV2z"D
\�\\111111►Ir��
��HN KFN
JUL 16 2018 � •�\GENSF• i ,
nt 63218
Permitting 1epartme - -
St. Lucie Co
unty, FL 18
•Kent, ATE OF !(�
Frq%'0n615g9i teei 18
Stat&61�,,(Gkj� L �G�0\
Irllllt\
Test Reports shall not be reproduced,except in full,without the written approval of GFA International Inc. Page 1 of 1
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on'any electronic copies.