Loading...
HomeMy WebLinkAboutHealth Department Septic Approval -6� `i'0e� okz9 �`p Oepa�� APPLICATION #:AP1307567 S ` , 'FLORIDA PERMIT #:56-SF-1790116 Q'SFWATMENT OF HEALTH �tr ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #:F11286705 ' y CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:09/20/2017 FEE PAID:400.00 RECEIPT #:56-Pf D-3375438 APPLICANT: Standard Pacific of Florida AGENT: The Milcor Group,Inc. PROPERTY ADDRESS: 13192 NW Wheaton Ln Palm City FL 34990 LOT: 3 BLOCK: SUBDIVISION: R[verbend ID#: 4425-703-0008-000-1 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ 1 [011 TANK SIZE [11 483.00 [21 800.00 [ 1 [271 SURFACE WATER FT [ ] [021 TANK MATERIAL _ Polypropylene [ ] [281 DITCHES FT [ 1 [031 OUTLET DEVICE [ 1 [291 PRIVATE WELLS FT [ 1 [041 MULTI-CHAMBERED [ Y N ] [ 1 [301 PUBLIC WELLS FT [ 1 [051 OUTLET FILTER [ ] [311 IRRIGATION WELLS FT [ 1 [061 LEGEND 1. 70-143-54SC4 2. 28-015-AA2C3 [ 1 [321 POTABLE WATER 24 FT [ 1 [071 WATERTIGHT [ 1 [331 BUILDING FOUNDATIONS 5 FT [ 1 [081 LEVEL [ ] (341 PROPERTY LINES 5 FT [ 1 [091 DEPTH TO LID [ ] (351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ 1 (101 AREA [1] 650 [21 SQFT [ ] [361 DRAINFIELD COVER [ 1 [111 DISTRIBUTION BOX HEADER X [ 1 [371 SHOULDERS [ 1 [121 NUMBER OF DRAINLINES 1. 5.00 2. [ ] [38] SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 05/15/2019 [ 1 (141 DRAINLINE SLOPE [ 1 [151 DEPTH OF COVER ADDITIONAL INFORMATION [ 1 [161 ELEVATION [ ABOVE / BELOW ]BM 1.00 [ 1 [401 UNOBSTRUCTED AREA [ 1 [171 SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [18] DOSING PUMPS 1.00 [ ] [421 ALARMS [ 1 [191 AGGREGATE SIZE [ 1 [431 MAINTENANCE AGREEMENT 1 [201 AGGREGATE EXCESSIVE FINES [ 1 [441 BUILDING AREA [ 1 [211 AGGREGATE DEPTH [ 1 [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ 1 [461 FINAL SITE GRADING [ 1 [221 FILL AMOUNT [ ] [471 CONTRACTOR Brian Davis(Brian Davis Sept [ 1 [231 FILL TEXTURE [ 1 [481 OTHER Drip Irrigation-Netafim [ ] [241 EXCAVATION DEPTH ABANDONMENT I 1 [251 AREA REPLACED [ ] [491 TANK PUMPED [ 1 [261 REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED 6 FILLED Comments: Comments are on page 2. CONSTRUCTION [ APPROVED / DISAPPROVED ) St. Lucie CHD DATE: 04/19/2019 Env ron ental Spec a st 11 Br J Ingram(ENVIRONMENTAL HEALTH) FINAL SYSTEM [ AppROVED / DISAPPROVED 1: t. Lucie CHD DATE: 05/15/2019 (Explanation of Violations on following page) Environmental Specialist II Sr gram(ENVIRONMENTAL HEALTH) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, PAC Page 2 of 3 EH Database v 1.0.1 AP1307567 EID1790116 APPLICATION #:AP1307567 STATE OF FLORIDA PERmIT #:56-SF-1790116 . ' DEPARTMENT OF HEALTH DOCUMENT #:F11286705 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM 09/20/2017 CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID: •ry�OpW"s FEE PAID:400.00 RECEIPT #:56-PID-3375438. Violation Number Comment Comments The system is sized for 5 bedrooms with a maximum occupancy of 10 persons(2 per bedroom),for a total estimated flow of 520 gpd.New 483 gal(70-143-54S-C4)trash tank,800 GPD ATU tank,483gal(70-143-54S-C4)DT,inline filter,Pentair S.T.E.P. 1/2 hp pump,and 5x65'long netafim drip line OF installed. No violations,system ok to cover. Contractor notified onsite. Needs final inspection for mound sytem,gutters,alarm check,2 year maintenance entity contract,ATU operating permit application,and Written notice of ATU. Final system approved. ATU operating permit issued 5/1412019. ME contract and written notice of ATU received 5/14/2019. ' Final system approved. Contractor,builder, and building department emailed final approval. • I DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Page 2 of 3 Incorporated: 64E-6.003, PAC EH Database v 1.0.1 AP1307567 EID1790116 i I