Loading...
HomeMy WebLinkAboutFiber Glass Impact Single Door 8-6-20plastpro 5200 W. CENTURY BLVD. LOS ANGELES, CA 90045 GLAZED FIBERGLASS SINGLE DOOR w/ or w/out SIDELITES INSWING/ OUTSWING "IMPACT" GENERAL NOTES 1. This product has been evaluated and is in compliance with the 7th Edition (2020) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind bome debris protection this product compiles with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. TABLE OF CONTENTS SHEET# DESCRIPTION 1 Typical elevations, design pressures & general notes 2 Door panel details and glaring detail 3 Sidelite panel details and glaring detail 4 Elevations 5 Horizontal cross sections 6 Vertical cross sections 7 Vertical cross sections 8 Buck anchoring 9 Frame anchoring 10 Hardware details 11 Bill of materials and components 37.25" MAX. FRAME WIDTH 115.U" MAX. OVERALL FRAME WIDTH 37.5" MAX. OVERALL FRAME WIDTH 1.50" 6 o. O X 0 OXO CONFIGURATION MAX. FRAME DIMENSION MAX. SIDELITE D.L.O. DIMENSION DESIGN PRESSURE (PSF) INSWING DESIGN PRESSURE (PSF) OUTSWING POSITIVE NEGATIVE POSITIVE NEGATIVE X 37.5" X 98.0" 20.5" X 78.25" +50.0 -50.0 +50.0 -50.0 OX/XO 76.25" X 980' 20.5" X 78.25" +50.0 -50.0 +50.0 -50.0 OXO 115.0" X 98.0" 20.5" X 78.25" +50.0 -50.0 1 +50.0 -50.0 J=U M Lgg`� o LO N ' M U N m v G oZ E. �mm ur "� m d a 0 c° Z c ui C1> d \j1 sr ic• N.T.S. Dwo.l JK cHx. er: LFS FL-17184.1 :Er 1 of 11 KMKSET LOCK SIGNATURE SERIES DEADBOLT: SIGNATURE SERIES(780) YALE LOCK YH COLLECTION DEADBOLT: YH COLLECTION (80 SERIES) KNOB: 'PSEmES(FTO) SCHIAGE DEADBOLT: 'r SERIES (860162) 35.75' MAX. DOOR PANEL WIDTH � LTOOR PANEL 1 \ HORIZONTAL CROSS SECTION 1.75' -►{ TOP RAIL (COMP.) FOAM CORE (POLYURETHANE - 1.9 PCF MIN.) 5/8" GLASS BITE EXT. I" OVERALL GLASS THK. . 1/8" ANNEALED GLASS �- 0.090"SAFLEX®PVB INTERLAYER 1 ff ANNEALED GLASS INTERIOR 1 AIR SPACE 1/8"TEMPERED GLASS #7-19 X 1-3/4" PPH J� ALUMINUM SPACER SELF DRILLING: 3A INT. NON STRUCTURAL SEALANT w !E w w G1 GLAZING DETAIL x LL O IARDWARE g O RT ir) of N STRUCTURAL SIUCINE (DOW 995) 24.27'MAX. NON STRUCTURAL SEALANT — FRAME WIDTH 20.5' MAX. D.L.O. WIDTH II I1.1 ODL LITE FRAME T 1.86" I n 0.0 C`1 3A ODL LITFRAME (Alum.) FIBERGLASS SKIN (0.075" THICK) �•:� d EXTERIOR BOTTOM RAIL (COMP.) VERTICAL CROSS SECTION 2 m .� i Al, >> Dz \\\ N M O r))�� U N •; v Z OZ¢ m Em 9 0 so cw oa p o0. w'7 mmda� co oZ 3w 3d J ` �o a� Zp 0O 0 aEn ck: m z? am oz 0 0¢ ELI gy: JK sr: LFS W NG NO.: FL-17184.1 Et 2 a, 11 3 N Cl N YI f NC Y X V 95.25' MAX. DOOR PANEL HEIGHT �{ 0 ST T a i oM O m Z 82.25 MAX. O.A. FRAME HEIGHTPC T - 78.25' MAX. D.L.O. HEIGHT m O M Q 0 p O N a 10.5' MAX O.C. (TYP.) Dy N N H �T1 fy] Z 11--#- A Z E�- b--i ZFf C A rn m 0 � v 2.79" a f---1.76" --►I � �t7 3 Do D. s 1 —� O m �m n� O n 1.75' I" P m n > W m ZC' J O 3 3� z A� z m m m m Z T Z y r A er® 0 V D yC n p G7 p O < O O G y m y K zsZ [T�y OO 3z�0 Zmm T �O A a r� m Scmjlf to v "vcaF••.T �. �.•� / / No.43409 August 06 2020 i c f i PRODUCT: PLASTPRO INC. Oooumente Prepared t1r: ,• Lyndon F. Schmid! Iw R 4 N 4 8 3 8115118 04 20 UPDATE TO 7th ED. 2020) FBC CORRECT WORDING IN D.P. TABLE DAC LFS FIBERGLASS DOOR P.E. No. 43408 /sar/Q •••• ��� o V r' m / •o� y ro 2 7 24 17 UPDATE 70 67H ED. 2017) FBC JK PART OR ASSEMBLY: /� BUILDING CONSULTANTS, INC. 04 22 15 UPDATE TO 5TH ED. 2014 FBC JK SIDELITE PANEL DETAILS d 1�� P.O. Box 230. Valrica, FL 33595 N NO DATE BY AND GLAZING DETAIL Phone No.: 813.659.9197 FBPE Registry No. 9813 REVISIONS 2012 R.W. BUILDING CONSULTANTS INC. \\dc01\rwbc\Clients\Plastpro, Inc PERMANENT\A - Florida Product Approvals\FL-17184 Fiberglass Door - Inswing-Outswing (BHI)\C - Drawings\FL-17184 (2020)\FL-17184.1-4.dwg m mr G O A W Z X o. A a+ N O. tr W rr O• A N A Q V -+ m V W O V N mr -Da V A VtN O Z V ch QQ ID 6 �\ O. W P A O• N Q O. w N � O. O. N A Q V A W N V Cn m f1n Zw W o o. A O N d A rh Yr W O ```�glnurrrrr�i �. F•SC.... No. 43409 Au = 06 2020 g g `� $ r1 PRODUCT: Dooument. Pnparad ey:i, .• `� '�,� •• �ORIDr`.•' PLASTPRO INC. FIBERGLASS DOOR Lyndon F. Schmidt `�� P.E.No. 43409 412 05 TO 7thG 2'FBC D 11A`5`�� 3 e 18 CORRECT WORDINUPDATE IND.P.7ABLE 2 7 24 17 UPDATE TO 6TH ED. 2017 FBC JK PART OR ASSEMBLY: BUILDING CONSULTANTS. INC. 1 04122,115 UPDATE TO 5TH ED. (2014) FBC JK z in ELEVATIONS J V►/ P•0. Box 230, Valrlco, FL 33595 NO DATE BY I' t) Phone No.: 813.659.9197 FBPE Registry No. 9813 REVISIONS 2131 0 R.W. BUILDING CONSULTANTS INC. Inc PERMANENT\♦ - Flonda Product m 17184 Fiberglass Door - InsWing-UutsWing It O L O O Z °> a. IFT. v fD O O) m O PC �� �0 m o� n 0� 113 N O T J� r_ Im Z 7� m T m rr�r119 . w S. !7t br yno K y :J COO z y 92,2 0 o �A n >o A Z o m a • /J m Rs!A O --1-1 Z M O � O O A � A "a Z No.43409 Au ust 06 2020 i a PRODUCT: Daeumante Pmpamd By:-V Lyndon F. ��i '•�OR... r 9 T N 4 8 04 20 UPDATE TO 7th ED. 2020 FBC DAC PLASTPRO INC. FIBERGLASS DOOR Schmidt � P.E. No. 43408 I,� s/O I� J o Z 3 8 15 16 CORRECT WORDING IN D.P. TABLE LFS $ -i 2 8 02 17 UPDATE TO 6TH ED. (2017 FBC JK PART OR ASSEMBLY: //� /t- BUILDING CONSULTANTS, INC. lY -iZto \ 1 4 22 15 UPDATE 70 STH ED. (2014 FBC JK HORIZONTAL J 1�� P.O. Box 230, Valrico, FL 33595 ro NO DATE BY CROSS SECTIONS Phone No.: 813.659.9197 REVISIONS FBPE Registry No. 9813 ® 2012 R.W. BUILDING CONSULTANTS INC. \\d Z rn m v ;v m m aw °• O PC g o ° 5m , P ° O PC ° v v > to In i 70 m C1 Po ) o v oQ o N P � 7nO •• v . z O O CC) n Z z 0 � m OD v w ° Q 29 ° a. w Z P v (D G °o CL V ° • 0.15 r ;v C'SINK oo vv 1-1 /4I MIN. (TYP-1 EMB. (TYP.) m rn 1-1 /4" MIN. m EMB. (TYP.) e •4 ° e• °.4 Z ° Z m P O a m A n . °. 0, a P• 70 ' P 3rn Po.. am o a O P w m . ° A ; N 70 EMB. (TYP.) ..' . 1-1 /4"MIN. EMB. (TYP.) 1-1/4" MIN. EMB. (TYP.) m m • 4 .P T G e . .ZO7 a CC. °o .• o c m P ' •4 Z C ;X• y ° P.0 Pp.• m OC c A V ''� c n °�. Y. Q pa 11 r •'P . N W V o y o 0Q - e. ti P'. 71 CZ m ° .0 Z • rn g 0 f n No.43409 EMB. (TYP Auclug k-26707 PRODUCT: Documents Prepared Sr.-" t " PLASTPRO INC. Lyndon F. Schmidt ��� FZO D�: \ �� 8 104/20 UPDATE TO 7th 18 CORRECT WORDING IN2020 TABLE OLFS FIBERGLASS DOOR P..EF- No. 43409 /ASS',Q�A`t yN„ 2 8 02 17 UPDATE TO 6TH ED. (2017 FBC JK PART OR ASSEMBLY: / IV BUILDING CONSULTANTS, INC. 1 04 22 15 UPDATE TO 5TH ED. 2014 FBC JK VERTICAL CROSS SECTIONS J I�YY P•0. Box 230. Valrico, FL 33595 N NO DATE BY Phone No.: 813.659.9197 REVISIONS I FBPE R.9latry No. 9813 ZO12 R.W. BUILDING CONSULTANTS INC. ' R M ° •' ui m m o p •' O M O m X Z O C3 VW ''R••••.. p V� M m < • u ' O < 7C A ° 4. a O 00 o y imp y '•A 'p T m m to'. O� Z 0 Z oO m c '• A G N a a' . to A °.' . 0.151-1 ' C'SINK MIN. (TYP,) c EMB. EMB. (TYP.) , a n a .•: .. , �r 1-1/4"MIN. EMB. (TYP.) •• 1-1/4' MIN. p EMB. (TYP.) R • p T V A •' to m o p O 4. Oy m 0(a o �O '• p p° 7 0 m >< CO e ct C ao O N ° N 0 " m CL . -.O m a y m ::• 0 Z o a CO. •. m M 0 po V Al v o m . $O$ y0y 7m7QQ �' •'v vt m Xs r- .•o p .� A H T D C O O A O v v, In !.. v .e CL 0 0 m m M O o m o v ! m 1-1 /4" MIN. Z • EMB. (TYP.) C2, 1-1/4"MIN. No.43409 -* . •: EMB, (TYP.) G/ * Au ust 06 2020 PRODUCT: PLASTPRO INC. Documents Pneperod By:�, .• Lyndon F. Schmidt ���� �O. N FIBERGLASS DOOR ... P.E. No. 43409 G�� 4 8 04 20 UPDATE TO 7th ED. 2020 FBC DAC 3 8 15 18 CORRECT WORDING IN D.P. TABLE LFS Ij v v o Z /////AL 11\�� 2 8 02 17 UPDATE TO 6TH ED. 2017 FBC JK PART OR ASSEMBLY: oo //� /t BUILDING CONSULTANTS, INC. 1 4 22 15 UPDATE TO 5TH ED. 2014 FBC JK x (n VERTICAL d li� P.O. Box 230, ValMeo, FL 33595 NO DATE BY Iv CROSS SECTIONS Phone No.: 813.659.9197 REVISIONS FBPE Reglet No. 9813 Inc MAMANEN I Vt - YIOnua p N -• r)33nmor) QQQ-00 mmmCDCL8A mB;m$a m 7 QrL r) q? �m,o an mRo6-72 B�'uo�R >> 3 3 m n- �Z s o� m as m 3 � 8 mo c �oc a m � o °m�io 3 :3 o mina 3 o �Qm 3 mna � o' m F3 uoor - inswing-umswing tunglL - C O n s X t7 18.5" MAX. 4" O.C. pp.)PYP.) 09 z 77% z z O' p x XOM <Zm Z T T OM A Tm� m � m3 T �a - — — — — — — — — — — — — — — — —- O Z -G O 18.S' MAX. (TYP,) O.C. (1YP.) 0 A m "o c 7�c z z Oj ------------------------ to 9 O zy E�OA On 0o Zz Aar b m :' rz' �� v 18.S' MAX. T^� O.C. (TYP.) 4° v x O ```,�1lnurrir��i SC%O�''�. 41 (TYP.) I No.43409 A—U.t nF;_ gron I� v P ' - ¢¢ F Z in i 12103 2 N PRODUCT: PLASTPRO INC. FIBERGLASS DOOR DUCUMente Pmp—d Lyndon F. Schmidt ��j�• •'• .... •''G\`��� P.E. No. 43409 lils$`1 11 10"`% J W BUILDING CONSULTANTS, INC. �/y PO. Box 230, Valrico, FL 33595 Phone No.: 813.859.9197 FBPE Registry No. 9813 75 UPDATE TO 7th G FBC Dj AC 3 8 18 CORRECT WORDIN4/20 INZD.P.)TABLE 2 B 02 17 UPDATE TO 6TH ED. (2017) FBC JK PART OR ASSEMBLY: BUCK ANCHORING f 22 15 UPDATE TO STH ED. 2014) FBC JK NO DATE BY REVISIONS 12012 R.W. BUILDING CONSUL—N-1 INC. \\dc01\rwbc\Clients\Plastpro, Inc PERMANENT\A - Florida Product Approvals\FL-17184 Fiberglass Door- Inswing-Outswing (BHI)\C- Drawings\FL-17184 (2020)\FL-17184.1-4.dwg 0Q 05$ CL 9=n a �3a �C) m Z UmZ =p0 0 0ib a� 0 0 I 0 4f N 033o�op O m'=�N01 c ?O z�m �g9 gm,go0 A 0 IT �� :.• •. LA. p aaafl�AA �s ..1 .sr . e:.'•. . ' 'mma a.o 0Ac'i OAF [� � � mCr m T Z q 7 6R n 3 � X2 D 2 rn 3 X X O c c • .1 • -a z t7 ^�0ZO �n g a q I I I 1 I I 1 14.5' MAX.) 6. (Tl'P.IH- 0 o c a O.C.(T(P.) =n� 003 = o g o� m c O I I I v T I I I I 14.25-MAX. O.C. (TYP.) y w_ 6 T z T Z zC= j MAX. 6- I►� O.C. O.C. (TYP.) (TfP.) —� X T () (7 ATo z Z G] I I I I I I X ` C C o n 0 D n z i 14.25' MAX.— O Z o T T Z r- O.C. (TYP.) Z _ � � t1 I I n z o o. Z -v SCH. f 14.5' MAX. 6.' (TYP.) ' O.C. (TYP.) Z No.43409 PLASTPRO INC. FIBERGLASS DOOR Lyndon F. S.hmtdt ��C��� •:�t„�s�"•' P.E. No. 43409 �i'1`2� �Q�A`t, PART OR ASSEMBLY: V�-�/�� BUILDING CONSULTANTS, INC. FRAME ANCHORING d 1i4Y P.O. Box 230, Valrico, FL 33595 Phone No.: 813.659.9197 FBPE Registry No. 9513 m 201 2 R.W. BUILD INS CONSULTANTS INC. \\dc01\rwbc\Clients\Plastpro, Inc PERMANENT\A - Florida Product Approvals\FL-17184 Fiberglass Door - Inswing-Outswing (BHI)\C - Drawings\FL-17184 (2020)\FL-17184.14.dwg 6 11" �— 48.375" m Am 3 m x 'z c1 T W I Fes— 26' 26" I 26' 9.25" s n x w v a v to 0 C; O A .+ z .. r- I� P. yZy No.43409 PLASTPRO INC. (Lyndon F. Schmidt FIBERGLASS DOOR P.E. No. 43409 PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. I HAREWARE DETAILS d I VY F"O. Box 230. volrlco, FL 33595 Phone No.: 813.659.9197 U BILL OF MATERIALS ITEM f DESCRIPIION MATERIAL A 1 X BUCK (SG >= 0.42) WOOD B 2X BUCK (SG >= 0.42) WOOD C 1 /4" MAX. SHIM SPACE - D 1 /4" X 2-3/4" DeWALT OR ITW CONCRETE SCREW STEEL E MASONRY - 3,000 PSI MIN, CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE F 1 /4" X 2-1/4"PFH DeWALT OR ITW CONCRETE SCREW STEEL G 3116" X 3-1 /4" PFH ITW CONCRETE SCREW STEEL H 1 /4" x 3-1 /4" PFH DeWALT OR ITW CONCRETE SCREW STEEL J 1/4" X 3-3/4" PFH DeWALT OR ITW CONCRETE SCREW STEEL K #9 X 2-1 /2" PFH WOOD SCREW STEEL L # 10 X 2-1 /2" PFH WOOD SCREW (1.15" MIN. EMBEDMENT) STEEL M #8 X 2" PFH WOOD SCREW STEEL N 1/4" X 1-3/4" PFH DeWALT OR ITW CONCRETE SCREW STEEL 7 FORCE 5 WEATHERSTRIP (ENDURA) FOAM 8 COMPRESSION WEATHERSTRIP QLON 650 (SCHLEGEL) FOAM 9 4" X 4" BUTT HINGE STEEL 10 #9 X 1" PFH WOOD SCREW STEEL 11 #9 X 3/4" PFH WOOD SCREW STEEL 20 FINGER JOINTED PINE FRAME, HEAD & HINGE JAMBS WOOD 21 POLY FIBER JAMB COMP. / VINYL 27 LATCH STRIKE PLATE STEEL 28 DEADBOLT STRIKE PLATE STEEL 29 SIDELITE SPACER (ISSLB) PVC 30 DOOR SWEEP PVC 31 OUTSWING THRESHOLD BY DLP (QOSH) ALUM. / WOOD 32 ADA THRESHOLD BY DLP (ISHC) ALUM. 33 INSWING THRESHOLD BY DLP (ISCS) ALUM. / WOOD 34 SIDELITE THRESHOLD BY DLP (ISH/ EIS) ALUM. / WOOD 35 TRIM WOOD 36 OUTSWING ADA BUMP THRESHOLD ALUM. 40 DOOR PANEL - SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS 60 SIDELITE PANEL - SEE SIDELITE PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS 88 2X REINFORCEMENT (CLEAR PINE: SG >= 0.49) WOOD I-� 4.56" —�-I I A zy � 2.36" —►I� 2.2" 2t1 HEAD 8 SIDE Jamb (— 4.56" � a F7. P I HEAD $ SIDE Poly fiberjamb 0 QQUTSOSHWING THRESHOLD S' rn 32 ADA SILL ISHC �n Tn D o �ZOUISWING ADA BUMP THRESHOLD OSHC 829 SIDELILE SPACER IS �ZINI NG THRESHOLD u ISCS SIDE_ ISH/ T THRESHOLD V _ M a. Q_z T O' m Z o N� J •O m G\� En onm U N •• 0 z o z Ec 9m� ug o O va m a a 4 ` Cc l\\ Oz c �d J R �2 M �o � ;das � m 0 EL a SCAM. N.r.s. MG. BY.. JK CHK. aY: LFS FL- 177 84.1 FT 11 OF 11