Loading...
HomeMy WebLinkAboutNOA # 20-0813.07MIAMIOADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, FL 33175 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.5!ov/economv Lawson Industries, Inc. 8501 NW 90 Street Medley, FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) and/ or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "SH-7700 (Flange Frame)" Aluminum Single Hung Window — L.M.I. APPROVAL DOCUMENT: Drawing No. L7700-0901, titled "Series-7700 Single Hung Flange Frame Impact Window", sheets 1 through 5 of 5, dated 05/27/09, with revision E dated 07/31/20, prepared by manufacturer, signed and sealed by Thomas J. Sotos, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LIMITATIONS: Insulated Glazing Options Types 6 and 7 are not approved to be installed above 30 feet in height without external protection device (shutters) LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA No. 17-1212.21 and consists of this page I and evidence pages E-I and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Sifang Zhao, P.E. QMIAMMIQ�ADECOMUN 12/17/2020 NOA No. 20-0813.07 Expiration Date: December 27, 2026 Approval Date: December 17, 2020 Page 1 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 09-0706.09) 2. Drawing No. L7700-0901, titled "Series-7700 Single Hung Flange Frame Impact Window", sheets 1 through 5 of 5, dated 05/27/09 with revision E dated 07/31/20, prepared by manufacturer, and signed and sealed by Thomas J. Sotos, P.E. B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of an aluminum single hung window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No. HETI- 09-2530A and HETI-09-2530B, dated 03/02/09, signed and sealed by Candido F. Font, P.E. (Submitted under NOA No. 09-0706.09) 2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of an aluminum single hung window, prepared by Hurricane Engineering & Testing, Inc., all Test Reports No. HETI-08-2003C, HETI-08-2004A, HETI-08-2060A & B, HETI-08-2061A & B, HETI-08-2062A & B, HETI-08-2063A & B, HETI-08-2064A & B, dated 03/15/08, signed and sealed by Candido F. Font, P.E. (Submitted under NOA No. 08-0825.17) 3. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of an aluminum single hung window, prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL- 2987 and FTL-2986, dated 04/03/01 and 03/27/01, all signed and sealed by Luis Antonio Figueredo, P.E. (Submitted under NOA No. 01-1009.01) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC, prepared by Lawson Industries, Inc., dated 05/28/09, revised on 01/18/10, signed and sealed by Thomas J. Sotos, P.E. (Submitted under NOA No. 11-0705.09) 2. Glazing complies with ASTM E1300-09 Sifang Zhao, P.E. Product Control Examiner NOA No. 20-0813.07 Expiration Date: December 27, 2026 Approval Date: December 17, 2020 E-1 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 12/28/17, expiring on 07/04/23. 2. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Interlayers" dated 01/19/17, expiring on 07/08/24. 3. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, complying with FBC-61h Edition (2017) dated 11/17/ 2017 and FBC 7th Edition (2020) dated 08/03/2020, and of no financial interest, , issued by manufacturer, signed and sealed by Thomas J. Sotos, P.E. 2. Statement letter of no financial interest, dated 05/28/09, issued by manufacturer, signed and sealed by Thomas J. Sotos, P.E. (Submitted under NOA No. 11-0705.09) 3. Laboratory compliance letter for all Test Reports No. HETI-09-2530A & B, issued by Hurricane Engineering & Testing, Inc., dated 03/02/09, signed and sealed by Candido F. Font, P.E. (Submitted under NOA No. 09-0706.09) 4. Laboratory compliance letter for Test Reports No. HETI-08-2003C, HETI-08- 2004A, HETI-08-2060A & B, HETI-08-2061A & B, HETI-08-2062A & B, HETI-08-2063A & B, HETI-08-2064A &B, issued by Hurricane Engineering & Testing, Inc., dated 03/15/08, signed and sealed by Candido F. Font, P.E. (Submitted under NOA No. 08-0825.17) 5. Laboratory compliance letter for Test Reports No. FTL-2987 and FTL-2986, issued by Fenestration Testing Laboratory, Inc., dated 04/03/01 and 03/27/01, signed and sealed by Luis Antonio Figueredo, P.E. (Submitted under NOA No. 01-0406.08) G. OTHERS 1. Notice of Acceptance No. 17-1212.21, issued to Lawson Industries, Inc. for their Series "SH-7700 (Flange Frame)" Aluminum Single Hung Window — L.M.I.", approved on 02/01/18 and expiring on 12/27/21. Sifang Zhao, P.E. Product Control Examiner NOA No. 20-0813.07 Expiration Date: December 27, 2026 Approval Date: December 17, 2020 E-2 INSTALLATION ANCHORS.— (A) 4 MAX. AT FRAME HEAD (B) NONE PER FRAME SILL (C) FRAME JAMBS (SEE SHEET 10 1/4' MAX. ABC` i j 3o MEETING R o � 9 7/8' 48• WIN➢OW FLANGE FRAME WIDTH l3 3/4' A MAX M x. D.L.O. Width ;r i =43 9 16 ii •- 0 INSTALLATION ANCHORS — (A ) 4 MAX. AT FRAME HEAD CB) NONE PER FRAME SILL (C) FRAME JAMBS (SEE SHEET o a" � 10 3/16- W I ' MAX. AH�VE �_ MEETING RAIL Nw n� 4i :- I AT MEETING om yo +RAILS 8 v2 .. II MAX. BELOW 7 MEETING Rqi WINDOW FLANGE FRAME WIDTH INSTALLATION ANCHORS, IO 15/16' AI (A) 4 MAX. AT FRAME HEAD (B) NONE PER FRAME SILL (C) FRAME JAMBS (SEE SHEET 40 C 6- 5• MAX: TIP• ALL CORNERS O. 10 a o II W> MAX. ABOVE Max. b.L.O. WidtH i B � i, ii nim u3 no aN i z ao � T AT 6• MEETING RAI RA1LS� 111/ « _ ua zx WINDOW FLANGE FRAME WIDTH MAX, O.0 A 3O.0 . L I ; T Mo ! D.L.O. Width -u 48 11/19�� rn'E N 0 U j "MAX. — (' C' EXT. 4 INT. FALSE COLONIAL C EXT, 4 INT. FALSE COLONIAL 52.125• MUNTINS ARE APPLIED W/ 52.I25' MUNTINS ARE APPLIED V/ 47.000• W/ SILICONE AND ARE W/ SILICONE AND ARE WINDOW BUCK WIDTH WINDOW BUCK WIDTH WINDOW BUCK WIDTH AVAILABLE AS OPTIONAL. AVAILABLE AS OPTIONAL. 48" x 78" EQUAL LITE ELEVATION UN -EQUAL LITE RADIUS ELEVATION UN -EQUAL LITE ELEVATION • INCLUDES UN -EQUAL LITE AND RADIUS HEAD (LIMITED TO LOADS ON SHEET 4 OF 5) (LIMITED TO LOADS ON SHEET 4 OF 5) General Notes: (LIMITED TO LOADS ON SHEET 4 OF 5) SERIES-7700 SINGLE HUNG IMPACT WINDOW — FLANGE FRAME 1.) THIS WINDOW SYSTEM IS DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS 53.125• OF THE FLORIDA BUILDING CODE (2017-6th Edition & 2020-7th Edition) INCLUDING INSTALLATION ANCHORS, WINDOW FLANGE FRAME WIDTH HIGH VELOCITY HURRICANE ZONE VELOCITY (HVHZ) AND ASTM 1300-09. (A) r4iONE MAX. A tFRnM s EA +� 13 3/4' THIS PRODUCT IS IMPACT RESISTANT. (SHUTTERS NOT REQUIRED) (C) FRAME JAMBS (SEE SHEET M4) MAX. O.C. , 2.) WOOD BUCKS SHALL BE INSTALLED AND ANCHORED SO THAT THE BUILDING 4 (= MAX RESISTS THE SUPERIMPOSED LOADS IN ACCORDANCE WITH THE REQUIREMENTS 6' (TYPICAL AT OF THE F.B.C. & TO BE REVIEWED BY BUILDING OFFICIAL. AlL cORNERs 3.) ANCHORS SHOWN ABOVE ARE AS PER TEST UNITS. ANCHORS ON ALL WINDOW SIZES M.x. D.L.O. Width ARE NOT TO EXCEED THESE MAXIMUM SPACINGS ON CENTER (O.C.) AND AS TABULATED =;;48 11/1QT- ON SHEET 4. 4.) ANCHOR CONDITIONS NOT DESCRIBED IN THESE DRAWING'S ARE TO HE R 9 5/8• ENGINEERED ON A SITE SPECIFIC BASIS, UNDER SEPARATE APPROVAL AND o MAX, ABOVE TO BE REVIEWED BY BUILDING OFFICIAL. Q s ;; • II D 5.) WINDOWS ARE QUALIFIED FOR USE WITH SINGLE GLAZE LAMINATED GLASS i�Z TYPES TABULATED HEREIN (SEE SHEET #3), AND FOR USE WITH DOUBLE GLAZE _1' aw -�� v+iS LAMINATED INSULATED GLASS TYPES TABULATED HEREIN (SEE SHEET #3). ^wy _ 6• MEETING 6.) SEE SHEET 3 FOR LOCK DETAILS & OPTIONS. A= RAID « no 7.) SEE SHEET 4 FOR DESIGN PRESSURES AND GLASS TYPES. �` 8.) FOR OPTIONAL FRAME INSTALLATION DETAILS SEE SHEET 3. a 1/� 9.) EXT. & INT. FALSE COLONIAL MUNTINS ARE OPTIONAL & AND ARE APPLIED W/ SILICONE w 9MA%! BELOW =-__ �/ -a 10.) WOOD BUCKS IN CONTACT WITH CONCRETE MUST BE PRESSURE TREATED AND ANCHORED MEETING Jo n (BY OTHERS), PRIOR TO WINDOW INSTALLATION. (SEE SHEET #2 FOR DETAIL & NOTES) All ' II WOOD BUCKS TO BE ANCHORED IN COMPLIANCE WITH THE FBC CHAPTER 24, PRODUCT REVISED as complying with the Florida SECTION 11.3.3.3. 6• Building Code 11.) APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE MULLED UNITS. MAX' NOA-No. 20-0813.07 12.) MULLING SINGLE HUNG WINDOWS WITH OTHER TYPES OF MIAMI-DADE COUNTY APPROVED C Expiration Date 12/27/2026 WINDOWS USING A MIAMI-DADE COUNTY APPROVED MULLION IN BETWEEN ARE ACCEPTABLE EXT. N INT. FALSE COLONIAL BUT THE LOWER DESIGN PRESSURE FROM THE WINDOWS OR MULLION APPROVAL WILL APPLY MUNTINS ARE APPLIED W/ s212s' By •`� �' TO THE ENTIRE MULLED SYSTEM. SILICONE AND ARE AV WINDOW BUCK WIDTH Miami -Dade Product Control 13.) SEE SHEET # 3 FOR MULLION/METAL ATTACHMENT DETAILS & OPTIONS. AVAILABLE As OPTIONAL. 14.) ALL METAL/STEEL IN CONTACT WITH ALUMINUM OR OTHER DISSIMILAR MATERIALS TO BE EQUAL LATE ELEVATION (LIMITED TO LOADS ON SHEET 4 OF 5) PAINTED OR PLATED AND SHALL MEET THE FLORIDA BLDG. CODE, Cn Or O O (a z LO in P.- I (~l a v L) a o o & .. q So W 3 01 -.4'~ z by t[ Z J Z O W a y ow z a C DW U' a O Z a o (5 � z U a U FZ C5 M ? x Z o ru; N Z �W7 a o N V O a 6 �z W o I � a� o 0 n $ $ c48;og $ coj m - o'b'b z z yrc u z s 1/4' TAPCUN W/ 1 1/4' MIN. EMBEDMENT INTO CONC, ALL WOOD BUCKS ENGINEERED SEPARATELY — (SEE ELEVATION AT SHEET #1 g TO BE REVIEWED BY BLDG. OFFICIAL (TYP.) FOR MAX. FASTENER SPACING) P.T WOOD DUCK NOT BY LAWSON IND. MUST SUSTAIN IMPOSED LOADS 1 1/e' MIN. EME D A 1. 1/4' MIN. .d EMBEDMENT a OI EXTERIOR GRA➢E PERIMETER CAULKING EXTERIOR O C O EXTERIOR PERIMETER SILICONE ADHESIVE BEDDING COMPOUND LAMINATED GLASS 24 INTERIOR MEETING RAILS 18 EXT. GRADE CAULK 9 5 O d: v• s a a: EX #14 S.M.S. V/ 1 1/4' MIN. EMBEDMENT INTO WOOD. (SEE ELEVATION AT SHEET #1 FOR MAX. FASTENER SPACING) SILICONE ADHESIVE 23 BEDDING COMPOUND (122 INTERIOR EXT. GRADE / I O #14 S.M.S. W/ 1 1/4' V MIN. II MIN. EMBEDMENT INTO WOOD. ➢GE DISTAtitE7 (SEE ELEVATION AT SHEET #1 FOR MAX. FASTENER SPACING) EXT. GRADE CAULK MIN. OJT Al MAX. iIM YP GLASS L,; rp ;,,. .PT. WOOD BUCKS u C 20 •1/4' TAPCON W/ 1 1/4' n °0 0 19 MIN. EMBEDMENT INTO CONC. "' (SEE ELEVATION AT SHEET #1 FOR MAX. FASTENER SPACING) N o 1 1/4: MIN• ? z EMBEDMENT I y�j = C 8 1 1/B' MIN. `. EDGE DISTANCE co DL EXTERIOR — a EXTERIOR GRADE •'-:?",.,'�; PERIMETER CAULKING -WINDOW FRAME WIDTH - WINDOW INSTALLATION NOTES: 1. THE WINDOW FRAME FLANGE TO BE BACK -BEDDED W/ AN EXT. GRADE CAULK THROUGHOUT THE ENTIRE PERIMETER OF FLANGE BY WINDOW INSTALLER (TYP.) / 2. THE EXPOSED EXT. PERIMETER OF THE WINDOW FRAME TO BE SEALED W/ AN APPROVED EXTERIOR GRADE CAULK K BY OTHERS (TYP.) • WHEN THE GAP BETWEEN THE WINDOW FRAME AND THE BUCK OR MASONRY IS LESS THAN 1/8% SHIMS ARE NOT REQUIRED. ANCHORS NOTE: ANCHORS TO BE #12 SMS OR WD. SCREWS INT❑ WOOD, OR 1 1/4' TAPCONS or APPROVED CONC. FASTENERS INT❑ CONC., WITH A MINIMUM OF 1 1/4' PENETRATION INTO WOOD OR CONC. (REFER TO LOAD TABLES AT SHEET 4 OF 5 FOR QUANTITIES REQUIRED) rc z va rc id m PRODUCT REVISED as complying with the Florida 41?P •: _0 G" Building Code w NDA-No. 20-0813.07 v�z�• '-' Expiration Date 'I 2/27/2026 0 ,`ti 1 m : v o�Pc0F.a'' , By Miami -Dade Product Control a 'ra/. 8 24 II 23 'SILICONE OPTIONS', DOW CORNING 899 SEMNEE-MDREHEA➢ 5731 ITREMCD SPECTRUM 2 GLAZING T GLAZING DEPTH LAMINATED GLASS COMPOSITION - TYPE 2 70'SY I GLASS DESCRIPTION ➢ETAD. Al L@lAT6 DBSCRD'110N I 2 1/8- ANNEALED GLASS 0.090' PLASTIC INTERLAYER AA9w� '_ _ _ _ J[B _ __ =�_� SAFLEX PVB by Enstnnn Chenlcnl co. 3 1/8' ANNEALED GLASS 1 .11 LAMINATED GLASS COMPOSITION - TYPE 3 rnm GLASS DESCRWIYON ➢BTA6 = _ _ -- Aoso � - _ - .ICB '- -- -'--� I 1 .41 LAIDNATR DESCROMON I 2 UB' ANNEALED GLASS 0.090- PLASTIC INTERLAYER SENTRYGLAS by Kurarny M-1co, Inc 3 Us- ANNEALED GLASS LAMINATED GLASS COMPOSITION - TYPE 4 ITHN GL199 DESCRD'07DN � ➢SI%6 IAMOTATE DE9CHOTION 1 1/8' ANNEALED GLASS —_ _ _- 2 0.0 M PLASTIC INTERLAYER _ _ _ _._ __ TRO -y PVH by .1/H' �-�- Kurorny Anerkn, Inc. 3 U8' ANNEALED GLASS ea4w LAMINATED GLASS COMPOSITION - TYPE 5 rlBx 1 GLASB ➢8''t LAMINATE DBSCRD nON t I/e' HEAT-STRENGHTENED GLASS 2 0.090' PLASTIC INTERLAYER 4 = _ _ TROSIFOL PVB by 7g1 == Kuraroy .-I., Inc. 3 1/8, HEAT-STRENGHTENED GLASS I 1 � A04w TT 20 23 'SILICONE OPTIONS- - DOW CORNING 899 SCHNEE-MOREHEAD 5731 24 TREMCO SPECTRUM 2 0.600' GLAZING DEPTH INSULATED LAMINATED GLASS COMPOSITION TYPE 8 ITEM CUSS DZSCRIPYION 01 D8'IAM L IMTE DRSCRO7TON 1 1/8' HEAT-STRENGHTENED GLASS Ye• _- _ _ ___ 1 2 0.090- PLASTIC INTERLAYER TROSIFOL PVB by 3 1/8' HEAT-STRENGHTENED GLASS = -_ Kuroroy Anerlcn, Inc. 4 1/4' INSULATED AIR SPACE J[r = = 5 1/8' ANNEALED GLASS I I nr4 INSULATED LAMINATED GLASS COMPOSITION TYPE 7 1T'K11 cuss DESCRaRON D$CAO, LAMINATE DESCRIPTION 1 1/6' ANNEALED GLASS 2 0.090- PLASTIC INTERLAYER .0 L4• SAFLEX PVB by 3 1/8' ANNEALED GLASS e• '__'__ _-_::= j 1 Eoslnnn Ch Klcol Co. 4 1/4- INSULATED AIR SPACE 5 1/8' ANNEALED GLASS 1 n04w GLAZING DETAILS AND OPTIONS NOTE: WINDOWS WITH GLASS TYPES "6 & 7" INSTALLED ABOVE 30It IN THE HVHZ, THE I.G. IN THE EXTERIOR LITE SHALL BE TEMPERED TO COMPLY WITH THE SMALL MISSILE IMPACT RESISTANCE REQUIREMENTS (FBC-2017, Chapter 24 Section 2411.3.3.7). 014 S.M.S. W/ 1 1/4' MIN. EMBEDMENT INTO WOOD. 26 (SEE ELEVATION AT SHEET ql , FOR MAX. FASTENER SPACING) t/v wx INTERIOR 6 6 SHIM SPACE INTERIOR FINISH NOT BY LAWSON IN➢USTRIES, INC.rZ ---- m EXT. GRADE BACK BEDDING 25 21 TO BE APPLIED BEHIND VINDOV FRAME FLANGE BY 52X 2X - INSTALLER (TYP.) aas�.WER, EXTERIOR EXT. GRADE PERIMETER CAULKING NOT BY LAWSON INDUSTRIES', TO BE APPLIED BY OTHERS C I JAMB (TYPJ METAL LATH NAILED TO WOOD FRAME INSTALLATION DETAIL ALUMINUM MULLION — SEE MULUON APPROVALS FOR MULUON TYPE, SIZE AND MAX. DESIGN PRESSURE LIMITATIONS. (ALUM. 0.078" MIN. THICK) NOTE: THE LOWER PRESSURES OF SINGLE HUNG WINDOW OR MULL SHALL GOVERN INTERIOR LOCK (LATCH AND SWEEP) OPTIONS 1. BOTH EXTRUDED ALUMINUM AND PLASTIC LIFT HANDLE LOCKS ARE QUALIFIED FOR USE ON ALL WINDOWS. 2. BOTH DIE CAST AND NYLON CAM LOCKS ARE QUALIFIED FOR USE ON ALL WINDOWS. 3. TWO (2) LOCKS ARE REQUIRED PER EACH VENT. -0 12 X 3/4' S.D.S. SEE MULLION APPROVALS FOR FLAT HEAD, PHILLIPS. MULLION TYPE, SIZE AND MAX. (SEE ELEVATION AND DESIGN PRESSURE LIMITATIONS. DP TABLES FOR QUANTITY INTERIOR NOTE: THE LOWER PRESSURES OF SINGLE AND FASTENER SPACING) 1/4' MAX. HUNG WINDOW OR MULL SHALL GOVERN FSHIM # 12 S.D.S. X 1 1/4' L. WSJ / SEE ELEV. FOR SPACING i NOTE: E o �q E E o 1. ALL STEEL IN CONTACT WITH 1-'-"-' - ALUM. TO RE PAINTED OR PLATED. o _ _ _ _ _ - 2. METAL STRUCTURES: v c v W »- A) STEEL : Fy - 36 K51 MIN. •¢ c x Q .9 o x (STEEL 18 GA. MIN. THICK - 0.048") 5 rc ¢ rc gg EXTERIOR PERIMETER WINDOW FRAME B) ALUMINUM : 6063-T5 MIN. x d o d c W k B EXTERIOR O SEALANT (ALUM. 0.078- MIN. THICK) v EXTERIOR GRADE E�+ PERIMETER CAULKING a a a FRAME MULLING DETAIL METAL STRUCTURE ATTACHMENT DETAIL PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0813.07 Expiration Date 12/2712026 Dy �J Miami -Dade Product Control W W w w K N (O N 0 O Coto fD N Orl) K) b N O m' -N wN O m tNJ N N m N W m" N W U1 N N Cn N N D7 N V lP N N co N -4cn lr N X m N V m N N V m N m N N V m N Co N N �l m (T CT 011 U) CT (n CT = (/) m m m m m m m s z 0 O Z = v z = 0 m m m 0 m m V V V V V m 000000tn� t` V O� V V W V QD A N A N A N A N A N p) W 07 W O W O) W O W O W (h O Ul tD CT O C)1 tD CT (O (.TI O ^^ YI O n V m v v y m m m A A N N A A N N m m W W m m W W m m W W m m W [Lf m m W W m m !D m n n m m m m p D A D y V C d co co rn m 3 as n m m m m m 3 xt cAi 0 cr o v y `�- m mmmm (D O O O m O m O m O mm O O m O m O mmmm O CD O O m O m O mmol O O O rn O A mmmm m 0 0 0 mmmmmmmmmm 0 o O O o 0 0 0 0 0 mmmmmm 0 0 o 0 0 0 mmmmmm 0 0 0 0 0 O A N 0 0 0 CD 0 0 0 0 0 0 CD 0 0 0 0 0 0 0 (D 0 0 C o 0 0 0 0 0 0 0 0 0 0 0 0 0 6600.0 0 0 0 0 0 0 <_ RCI a m } 4 cC c� Z 0 b m O m -4 �o o0...... 0C) 00000 o as 0 o CD auw 0000 o 00 o 00000 w aow au co Cl N � p Vmmmmmmmmmmmmmmmmmmmmmmmmm tp0000000000000000000000000p,i� 0 0 CD 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O K 1 o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 y a •p � z v A. v x G) m H m r,co,O O O O O c O c O 003c000 O O O O O 0o,0 O O O ca,o,c O O O O 0�� O O O t0N�1 O) N Z �mmmmmmmmmmmmmmmmmmmmmmmmm m O 000000000000000000000.000 ply Z O O O 0 0 0 0 O o 0 0 0 0 0 0 0 0 0 0 0 0 y o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 V a m C I n 0 a o N x1 x1 I W d C 0 G+1 C E.IJ Em d m zm�y x D-.0 m 3 ° � ao O 1 o ?ma C y p 'd om O c j N O SC fJ E2 �N t7 7 ` W o m N 0 � � a N V S IL O) PROFESSIONAL ENGINE FL LIC. # 55225 N N N f0 W m N N v tD W co N N V fD W Co N-4 N o' f0 W Co N N -4 !O •tm.1 c. N N v fp W co N N v m tp v co m N N m m m N N m m m N N m m m N N m m m N N m m m N N m m m N= m Z V V V A V V A V A m 0 m m 0 0 m m 0 0 m W 0 O) W W m m W W 00 W W = G C 0C G V V m m V V m m V A m N A tJ N A !J tJ m N W m m W W m m W W m m W W m m W m m m W m m W m m m m m m W W W W W -4 N W m -4 N N m m N N m m N m m m m m m m N N N d m 00 m m m A A S 0 3 # tr °m O y "4 V m m O O m V O A m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 O m m O O m m O O co O N tR Z (O fD o A -4 -4m fp m 0 0 m 0 m m 0 0 m m 0 0 m m 0 0 m m o O m m o 0 Co m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 m m 0 O m m O O m m O O m m o 0 m m 0 0 m m 0 0 m 0 W A 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 T A m 0 m 0 m 0 m 0 mmmm 0 m m m m m m m m m m m m m m m m m m m m m 0) A xi\ 0 0' 00 0 0 0 0' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 A b a r t5 d m m o m o m o mmmm o 0 0 0 mmmm o 0 0 m 0 0 Co Co 0 0 Co m 0 0 m m 0 0 m m 0 0 Co m 0 0 m m 0 0 m m 0 0 m m 0 0 m o p, �i 2 o O O i O i O i 0000 O tatdn N y m D m o i m 0 m 0, mmmm 0 0 0.0 mmmm O O O mmmm O O O o m O O m m O 0 m m 0 0 m m 0 O m m O O m m o O m m 0 O m o m a ID V m m m m m m 'O m m m m m m 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m m 0 0 m 0 tR f0 0 0 0 0 0 0 0 0 0 0 O 0 0 O o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 V 0 a N NWs B. Revised to Comply w 2010 FBC m �/ Illll 8501 N.W. 90 ST. L xtl� S O MEDLEY, FLORIDA 33166 INDUSTRIES, INC. PH No. (305) 696-8660 MANUFACTURER OF QUALITY ALUMINUM WINDOWS AND GLASS DOORS 4 B. Revised to Com I w 201FBC C. Compliance w/ FBC 5l� Edition (zo14) end ASTM E1300-os D. Revised to Comply W/ 2017 FBC E.Revised to Com W 2oio FBC e N. ERAzO D'L0s z7-09 SERIES-7700 SINGLE HUNG FLANGE FRAME IMPACT WINDOW w N. Erflzo ow 07/31/ Nw20 1/ DESIGN PRESSURE CHARTS, & CONFIGURATION OPTIONS LavrL• E Sow4: Prodvat Bf—. N,.w . a'e.�, Nv — L7700-0901 stir 4 OF 5 Rni4bn FRAME HEAD L-7701 O .500 F.062 i Etc 2.651�- ( 80G9-T5 ALU1@N1i ) FRAME SILL L-7702 FIXED MEETING RAIL L-7704 C FRAME JAMB L-77C' O VENT INTERLOCK RAIL VENT BOTTOM RAIL L-7705 L-7706 O( GOBS -TB ALVblINllx ) O ( 6063_T6 ALUMINUM ) VENT JAMB RAIL L-7707 O( 6063-T6 ALUMINUM ) �1.375� 062 1.II 5 VENT SPRING LATCH GLAZING BEAD GLAZING BEAD GLAZING BEAD L-7539 L-7708 L-7711 L-4204 O O 16 17 .062 ( GOB3-76 ALUIO R ) ( 6083-T5 ALUllMUM ) ( 8003-T� ALUMINUM } ase --1 — soa 1.013 L .391 ­­1—II .698 J466 ( M63-T5 AU/MU ) t O I FRAME TOP CORNER 9 I I I I I FRAME HEAO FRAME JAMB FR MF SILL ( r� FRAME BOTTOM CORNER � O•�• 3 �• VENT TOP CORNER 9 4 VENT JAMB RAIL VEM T01 RAIL O VENT BOTTOM CORNER FRAME & SASH CORNER DETAILS BILL OF MATERIALS ITEM # PART # REQD. DESCRIPTION REMARKS 1 L-7801 1 FLANGE FRAME HEAD 6063-T6 ALUMINUM 2 L-7802 1 FLANGE FRAME SILL 6063-T6 ALUMINUM 3 L-7803 2 FLANGE FRAME JAMB 6063-T6 ALUMINUM 4 L-7704 1 FRAME FIXE➢ MEETING RAIL 6063-T6 ALUMINUM 5 L-7705 1 VENT MEETING (TOP) RAIL 6063-T6 ALUMINUM 6 L-7706 1 VENT BOTTOM (LATCH) RAIL 6063-T6 ALUMINUM 7 L-7707 2 VENT JAMB (SIDE) RAIL 6063-T6 ALUMINUM 8 L-7708 AS REQD. GLAZING BEAD C 3/8' ) 6063-T5 ALUMINUM 9 FS-006 AS REQD. FRAME ASSEMBLY SCREWS #8 X 3/4' P.H. PHILLIPS 10 FS-040 AS REQD. INSTALLATION SCREWS #14 X 1 1/4' F.H./PHIL, 11 L-7531 AS REQD. BULB VINYL WTST 1/4' DIA. BULB #3033 12 PWS-003 AS REQ'➢. FIN SEAL WEATHERSTRIP ,187'x.230' 13 PWS-005 AS REQ'D. FIN SEAL WEATHERSTRIP .187'x.350' 14 PWS-009 AS REQD. FIN SEAL WEATHERSTRIP .187'x.310' 15 HC-024-1 2 SELF ADHESIVE PILE PAD 1/4' X 1 1/2' 16 L-7711 AS REQ'D. GLAZING BEAD/ INSULATED 6063-T5 ALUMINUM 17 L-4204 AS REQD, GLAZING BEAD - RADIUS 6063-T5 ALUMINUM 18 L-7723 1 SASH BALANCE CAM/GUIDE (2 X VENT) 19 L-7725 2 RIGID VINYL SASH STOP C2 X FRAME) 20 L-7727 2 BLOCK & TACKLE BALANCE BSI Balance Systems 21 L-7539 2 VENT LIFT LATCH 6063-T5 ALUMINUM 22 L-7523 1X LATCH VENT LATCH SPRING STAINLESS STEEL 23 x AS REQD. GLAZING SILICONE SEE GLAZING @ SHT. 3 24 x 2 Laminated Glass SEE GLAZING DETAILS 25 HC-057-Ij 2 VENT LIFT LATCH MOLDED NYLON 26 HC-058-1 2 VENT SWEEP LATCH MOLDED NYLON 27 ■ 2 FRAME SILL FOAM GASKET SELF ADHESIVE 28 HC-026-1 1 SCREEN FRAME & MESH 29 L-7730 1 PRODUCT LABEL 30 X x A X 31 SM-5504 AS REQD. JOINT SEALANT SM-5504 32 x AS REQ'D.j PERIMETER ACRYLIC CAULK OSI POLYSEAMSEAL PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0813.07 Expiration Date 12/27/2026 By 11-- ' Miami -Dade Product Control cw8.2 PWG W u �o-H I z z 2 d m u `o c w w Z. i �•