HomeMy WebLinkAboutNOA # 20-0813.07MIAMIOADE MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, FL 33175
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.5!ov/economv
Lawson Industries, Inc.
8501 NW 90 Street
Medley, FL 33166
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami -Dade County) and/ or the AHJ (in areas other than Miami -Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in the
accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,
modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke
this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material
fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: Series "SH-7700 (Flange Frame)" Aluminum Single Hung Window — L.M.I.
APPROVAL DOCUMENT: Drawing No. L7700-0901, titled "Series-7700 Single Hung Flange Frame Impact
Window", sheets 1 through 5 of 5, dated 05/27/09, with revision E dated 07/31/20, prepared by manufacturer,
signed and sealed by Thomas J. Sotos, P.E., bearing the Miami -Dade County Product Control Revision stamp with
the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LIMITATIONS: Insulated Glazing Options Types 6 and 7 are not approved to be installed above 30 feet in
height without external protection device (shutters)
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises and renews NOA No. 17-1212.21 and consists of this page I and evidence pages E-I and E-2,
as well as approval document mentioned above.
The submitted documentation was reviewed by Sifang Zhao, P.E.
QMIAMMIQ�ADECOMUN
12/17/2020
NOA No. 20-0813.07
Expiration Date: December 27, 2026
Approval Date: December 17, 2020
Page 1
Lawson Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Manufacturer's die drawings and sections.
(Submitted under NOA No. 09-0706.09)
2. Drawing No. L7700-0901, titled "Series-7700 Single Hung Flange Frame Impact
Window", sheets 1 through 5 of 5, dated 05/27/09 with revision E dated 07/31/20,
prepared by manufacturer, and signed and sealed by Thomas J. Sotos, P.E.
B. TESTS
1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of an aluminum single hung
window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No. HETI-
09-2530A and HETI-09-2530B, dated 03/02/09, signed and sealed by Candido F.
Font, P.E. (Submitted under NOA No. 09-0706.09)
2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of an aluminum single hung
window, prepared by Hurricane Engineering & Testing, Inc., all Test Reports No.
HETI-08-2003C, HETI-08-2004A, HETI-08-2060A & B, HETI-08-2061A & B,
HETI-08-2062A & B, HETI-08-2063A & B, HETI-08-2064A & B, dated 03/15/08,
signed and sealed by Candido F. Font, P.E. (Submitted under NOA No. 08-0825.17)
3. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94
along with marked -up drawings and installation diagram of an aluminum single hung
window, prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL-
2987 and FTL-2986, dated 04/03/01 and 03/27/01, all signed and sealed by Luis
Antonio Figueredo, P.E. (Submitted under NOA No. 01-1009.01)
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC,
prepared by Lawson Industries, Inc., dated 05/28/09, revised on 01/18/10, signed and
sealed by Thomas J. Sotos, P.E. (Submitted under NOA No. 11-0705.09)
2. Glazing complies with ASTM E1300-09
Sifang Zhao, P.E.
Product Control Examiner
NOA No. 20-0813.07
Expiration Date: December 27, 2026
Approval Date: December 17, 2020
E-1
Lawson Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their
"SentryGlas® (Clear and White) Glass Interlayers" dated 12/28/17, expiring on
07/04/23.
2. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. for their
"Trosifol® Ultraclear, Clear and Color PVB Interlayers" dated 01/19/17, expiring
on 07/08/24.
3. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA)
for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on
05/21/21.
F. STATEMENTS
1. Statement letter of conformance, complying with FBC-61h Edition (2017) dated 11/17/
2017 and FBC 7th Edition (2020) dated 08/03/2020, and of no financial interest, ,
issued by manufacturer, signed and sealed by Thomas J. Sotos, P.E.
2. Statement letter of no financial interest, dated 05/28/09, issued by manufacturer,
signed and sealed by Thomas J. Sotos, P.E. (Submitted under NOA No. 11-0705.09)
3. Laboratory compliance letter for all Test Reports No. HETI-09-2530A & B, issued by
Hurricane Engineering & Testing, Inc., dated 03/02/09, signed and sealed by Candido
F. Font, P.E. (Submitted under NOA No. 09-0706.09)
4. Laboratory compliance letter for Test Reports No. HETI-08-2003C, HETI-08-
2004A, HETI-08-2060A & B, HETI-08-2061A & B, HETI-08-2062A & B,
HETI-08-2063A & B, HETI-08-2064A &B, issued by Hurricane Engineering &
Testing, Inc., dated 03/15/08, signed and sealed by Candido F. Font, P.E.
(Submitted under NOA No. 08-0825.17)
5. Laboratory compliance letter for Test Reports No. FTL-2987 and FTL-2986, issued
by Fenestration Testing Laboratory, Inc., dated 04/03/01 and 03/27/01, signed and
sealed by Luis Antonio Figueredo, P.E. (Submitted under NOA No. 01-0406.08)
G. OTHERS
1. Notice of Acceptance No. 17-1212.21, issued to Lawson Industries, Inc. for their
Series "SH-7700 (Flange Frame)" Aluminum Single Hung Window — L.M.I.",
approved on 02/01/18 and expiring on 12/27/21.
Sifang Zhao, P.E.
Product Control Examiner
NOA No. 20-0813.07
Expiration Date: December 27, 2026
Approval Date: December 17, 2020
E-2
INSTALLATION ANCHORS.—
(A) 4 MAX. AT FRAME HEAD
(B) NONE PER FRAME SILL
(C) FRAME JAMBS (SEE SHEET
10 1/4'
MAX. ABC`
i j
3o MEETING R
o �
9 7/8'
48•
WIN➢OW FLANGE FRAME WIDTH
l3 3/4'
A
MAX
M x. D.L.O. Width ;r
i
=43 9 16 ii •-
0
INSTALLATION ANCHORS —
(A ) 4 MAX. AT FRAME HEAD
CB) NONE PER FRAME SILL
(C) FRAME JAMBS (SEE SHEET
o a"
�
10 3/16-
W I
'
MAX. AH�VE
�_ MEETING RAIL
Nw
n� 4i
:-
I AT
MEETING
om yo
+RAILS
8 v2
..
II MAX. BELOW
7 MEETING Rqi
WINDOW FLANGE FRAME WIDTH
INSTALLATION ANCHORS,
IO 15/16' AI
(A) 4 MAX. AT FRAME HEAD
(B) NONE PER FRAME SILL
(C) FRAME JAMBS (SEE SHEET 40
C
6-
5• MAX: TIP•
ALL CORNERS
O.
10 a
o
II
W>
MAX. ABOVE
Max. b.L.O. WidtH
i
B
�
i, ii
nim u3
no aN
i
z ao
�
T AT
6• MEETING
RAI
RA1LS�
111/ «
_ ua
zx
WINDOW FLANGE FRAME WIDTH
MAX, O.0
A 3O.0
.
L
I ; T
Mo ! D.L.O. Width
-u 48 11/19��
rn'E
N
0 U
j "MAX. —
(' C' EXT. 4 INT. FALSE COLONIAL C
EXT, 4 INT. FALSE COLONIAL 52.125• MUNTINS ARE APPLIED W/ 52.I25'
MUNTINS ARE APPLIED V/ 47.000• W/ SILICONE AND ARE
W/ SILICONE AND ARE WINDOW BUCK WIDTH WINDOW BUCK WIDTH WINDOW BUCK WIDTH
AVAILABLE AS OPTIONAL.
AVAILABLE AS OPTIONAL. 48" x 78" EQUAL LITE ELEVATION UN -EQUAL LITE RADIUS ELEVATION UN -EQUAL LITE ELEVATION
• INCLUDES UN -EQUAL LITE AND RADIUS HEAD (LIMITED TO LOADS ON SHEET 4 OF 5) (LIMITED TO LOADS ON SHEET 4 OF 5)
General Notes: (LIMITED TO LOADS ON SHEET 4 OF 5) SERIES-7700 SINGLE HUNG IMPACT WINDOW — FLANGE FRAME
1.) THIS WINDOW SYSTEM IS DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS 53.125•
OF THE FLORIDA BUILDING CODE (2017-6th Edition & 2020-7th Edition) INCLUDING INSTALLATION ANCHORS, WINDOW FLANGE FRAME WIDTH
HIGH VELOCITY HURRICANE ZONE VELOCITY (HVHZ) AND ASTM 1300-09. (A) r4iONE MAX. A tFRnM s EA +� 13 3/4'
THIS PRODUCT IS IMPACT RESISTANT. (SHUTTERS NOT REQUIRED) (C) FRAME JAMBS (SEE SHEET M4) MAX. O.C. ,
2.) WOOD BUCKS SHALL BE INSTALLED AND ANCHORED SO THAT THE BUILDING 4 (= MAX
RESISTS THE SUPERIMPOSED LOADS IN ACCORDANCE WITH THE REQUIREMENTS 6' (TYPICAL AT
OF THE F.B.C. & TO BE REVIEWED BY BUILDING OFFICIAL. AlL cORNERs
3.) ANCHORS SHOWN ABOVE ARE AS PER TEST UNITS. ANCHORS ON ALL WINDOW SIZES M.x. D.L.O. Width
ARE NOT TO EXCEED THESE MAXIMUM SPACINGS ON CENTER (O.C.) AND AS TABULATED =;;48 11/1QT-
ON SHEET 4.
4.) ANCHOR CONDITIONS NOT DESCRIBED IN THESE DRAWING'S ARE TO HE R 9 5/8•
ENGINEERED ON A SITE SPECIFIC BASIS, UNDER SEPARATE APPROVAL AND o MAX, ABOVE
TO BE REVIEWED BY BUILDING OFFICIAL. Q s ;; • II D
5.) WINDOWS ARE QUALIFIED FOR USE WITH SINGLE GLAZE LAMINATED GLASS i�Z
TYPES TABULATED HEREIN (SEE SHEET #3), AND FOR USE WITH DOUBLE GLAZE _1' aw -�� v+iS
LAMINATED INSULATED GLASS TYPES TABULATED HEREIN (SEE SHEET #3). ^wy _ 6• MEETING
6.) SEE SHEET 3 FOR LOCK DETAILS & OPTIONS. A= RAID « no
7.) SEE SHEET 4 FOR DESIGN PRESSURES AND GLASS TYPES. �`
8.) FOR OPTIONAL FRAME INSTALLATION DETAILS SEE SHEET 3. a 1/�
9.) EXT. & INT. FALSE COLONIAL MUNTINS ARE OPTIONAL & AND ARE APPLIED W/ SILICONE w 9MA%! BELOW =-__ �/ -a
10.) WOOD BUCKS IN CONTACT WITH CONCRETE MUST BE PRESSURE TREATED AND ANCHORED MEETING Jo n
(BY OTHERS), PRIOR TO WINDOW INSTALLATION. (SEE SHEET #2 FOR DETAIL & NOTES) All
' II
WOOD BUCKS TO BE ANCHORED IN COMPLIANCE WITH THE FBC CHAPTER 24, PRODUCT REVISED
as complying with the Florida
SECTION 11.3.3.3. 6• Building Code
11.) APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE MULLED UNITS. MAX' NOA-No. 20-0813.07
12.) MULLING SINGLE HUNG WINDOWS WITH OTHER TYPES OF MIAMI-DADE COUNTY APPROVED C Expiration Date 12/27/2026
WINDOWS USING A MIAMI-DADE COUNTY APPROVED MULLION IN BETWEEN ARE ACCEPTABLE EXT. N INT. FALSE COLONIAL
BUT THE LOWER DESIGN PRESSURE FROM THE WINDOWS OR MULLION APPROVAL WILL APPLY MUNTINS ARE APPLIED W/ s212s' By •`� �'
TO THE ENTIRE MULLED SYSTEM. SILICONE AND ARE AV WINDOW BUCK WIDTH Miami -Dade Product Control
13.) SEE SHEET # 3 FOR MULLION/METAL ATTACHMENT DETAILS & OPTIONS. AVAILABLE As OPTIONAL.
14.) ALL METAL/STEEL IN CONTACT WITH ALUMINUM OR OTHER DISSIMILAR MATERIALS TO BE EQUAL LATE ELEVATION
(LIMITED TO LOADS ON SHEET 4 OF 5)
PAINTED OR PLATED AND SHALL MEET THE FLORIDA BLDG. CODE,
Cn
Or
O
O (a
z
LO
in
P.-
I
(~l a v
L)
a
o
o & .. q
So
W
3 01 -.4'~
z
by
t[
Z J Z O
W
a
y
ow z
a
C
DW
U'
a
O
Z
a
o
(5
�
z
U
a
U FZ
C5
M ?
x
Z
o
ru;
N
Z
�W7
a
o
N V
O
a
6
�z
W
o
I
�
a�
o
0
n
$
$
c48;og $ coj m
- o'b'b z z
yrc u z s
1/4' TAPCUN W/ 1 1/4'
MIN. EMBEDMENT INTO CONC,
ALL WOOD BUCKS ENGINEERED SEPARATELY —
(SEE ELEVATION AT SHEET #1
g TO BE REVIEWED BY BLDG. OFFICIAL (TYP.)
FOR MAX. FASTENER SPACING)
P.T WOOD DUCK NOT BY LAWSON IND.
MUST SUSTAIN IMPOSED LOADS
1 1/e' MIN.
EME D A
1. 1/4' MIN.
.d EMBEDMENT
a
OI
EXTERIOR GRA➢E
PERIMETER CAULKING
EXTERIOR
O
C
O
EXTERIOR
PERIMETER
SILICONE ADHESIVE
BEDDING COMPOUND
LAMINATED GLASS
24
INTERIOR
MEETING
RAILS 18
EXT. GRADE
CAULK
9 5 O
d:
v• s a
a:
EX
#14 S.M.S. V/ 1 1/4'
MIN. EMBEDMENT INTO WOOD.
(SEE ELEVATION AT SHEET #1
FOR MAX. FASTENER SPACING)
SILICONE ADHESIVE
23 BEDDING COMPOUND
(122 INTERIOR
EXT. GRADE / I O
#14 S.M.S. W/ 1 1/4' V MIN. II
MIN. EMBEDMENT INTO WOOD. ➢GE DISTAtitE7
(SEE ELEVATION AT SHEET #1
FOR MAX. FASTENER SPACING)
EXT. GRADE
CAULK
MIN.
OJT
Al
MAX.
iIM
YP
GLASS
L,; rp ;,,.
.PT. WOOD BUCKS
u
C
20
•1/4' TAPCON W/ 1 1/4'
n °0 0
19
MIN. EMBEDMENT INTO CONC.
"' (SEE ELEVATION AT SHEET #1
FOR MAX. FASTENER SPACING)
N o
1 1/4: MIN•
? z
EMBEDMENT I
y�j = C
8
1 1/B' MIN.
`. EDGE DISTANCE
co DL
EXTERIOR — a
EXTERIOR GRADE •'-:?",.,'�;
PERIMETER CAULKING
-WINDOW FRAME WIDTH -
WINDOW INSTALLATION NOTES:
1. THE WINDOW FRAME FLANGE TO BE BACK -BEDDED W/ AN EXT.
GRADE CAULK THROUGHOUT THE ENTIRE PERIMETER OF FLANGE
BY WINDOW INSTALLER (TYP.)
/ 2. THE EXPOSED EXT. PERIMETER OF THE WINDOW FRAME TO
BE SEALED W/ AN APPROVED EXTERIOR GRADE CAULK
K BY OTHERS (TYP.)
• WHEN THE GAP BETWEEN THE WINDOW FRAME AND THE BUCK OR
MASONRY IS LESS THAN 1/8% SHIMS ARE NOT REQUIRED.
ANCHORS NOTE:
ANCHORS TO BE #12 SMS OR WD. SCREWS INT❑ WOOD, OR
1 1/4' TAPCONS or APPROVED CONC. FASTENERS INT❑ CONC.,
WITH A MINIMUM OF 1 1/4' PENETRATION INTO WOOD OR
CONC. (REFER TO LOAD TABLES AT SHEET 4 OF 5 FOR
QUANTITIES REQUIRED)
rc z va rc
id m
PRODUCT REVISED
as complying with the Florida 41?P •: _0 G"
Building Code w
NDA-No. 20-0813.07 v�z�• '-'
Expiration Date 'I 2/27/2026 0 ,`ti 1 m : v
o�Pc0F.a'' ,
By
Miami -Dade Product Control a 'ra/.
8
24 II
23
'SILICONE OPTIONS',
DOW CORNING 899
SEMNEE-MDREHEA➢ 5731
ITREMCD SPECTRUM 2
GLAZING
T
GLAZING DEPTH
LAMINATED GLASS COMPOSITION
- TYPE 2
70'SY
I GLASS DESCRIPTION
➢ETAD.
Al
L@lAT6 DBSCRD'110N
I
2
1/8- ANNEALED GLASS
0.090' PLASTIC INTERLAYER
AA9w� '_ _ _ _
J[B _ __ =�_�
SAFLEX PVB by
Enstnnn Chenlcnl co.
3
1/8' ANNEALED GLASS
1 .11
LAMINATED GLASS COMPOSITION
- TYPE 3
rnm
GLASS DESCRWIYON
➢BTA6
= _ _ --
Aoso � - _ -
.ICB '- -- -'--�
I 1 .41
LAIDNATR DESCROMON
I
2
UB' ANNEALED GLASS
0.090- PLASTIC INTERLAYER
SENTRYGLAS by
Kurarny M-1co, Inc
3
Us- ANNEALED GLASS
LAMINATED GLASS COMPOSITION - TYPE 4
ITHN GL199 DESCRD'07DN � ➢SI%6 IAMOTATE DE9CHOTION
1 1/8' ANNEALED GLASS —_ _ _-
2 0.0 M PLASTIC INTERLAYER _ _ _ _._ __ TRO -y PVH by
.1/H' �-�- Kurorny Anerkn, Inc.
3 U8' ANNEALED GLASS ea4w
LAMINATED GLASS COMPOSITION - TYPE 5
rlBx 1 GLASB ➢8''t LAMINATE DBSCRD nON
t I/e' HEAT-STRENGHTENED GLASS
2 0.090' PLASTIC INTERLAYER 4 = _ _ TROSIFOL PVB by
7g1 == Kuraroy .-I., Inc.
3 1/8, HEAT-STRENGHTENED GLASS I 1 � A04w
TT 20
23
'SILICONE OPTIONS-
- DOW CORNING 899
SCHNEE-MOREHEAD 5731
24 TREMCO SPECTRUM 2
0.600'
GLAZING DEPTH
INSULATED LAMINATED GLASS COMPOSITION TYPE 8
ITEM CUSS DZSCRIPYION 01
D8'IAM L IMTE DRSCRO7TON
1 1/8' HEAT-STRENGHTENED GLASS Ye• _- _ _ ___ 1
2 0.090- PLASTIC INTERLAYER TROSIFOL PVB by
3 1/8' HEAT-STRENGHTENED GLASS = -_ Kuroroy Anerlcn, Inc.
4 1/4' INSULATED AIR SPACE J[r = =
5 1/8' ANNEALED GLASS I I nr4
INSULATED LAMINATED GLASS COMPOSITION TYPE 7
1T'K11 cuss DESCRaRON D$CAO, LAMINATE DESCRIPTION
1 1/6' ANNEALED GLASS
2 0.090- PLASTIC INTERLAYER .0 L4• SAFLEX PVB by
3 1/8' ANNEALED GLASS e• '__'__ _-_::= j 1 Eoslnnn Ch Klcol Co.
4 1/4- INSULATED AIR SPACE
5 1/8' ANNEALED GLASS 1 n04w
GLAZING DETAILS AND OPTIONS
NOTE:
WINDOWS WITH GLASS TYPES "6 & 7" INSTALLED ABOVE 30It
IN THE HVHZ, THE I.G. IN THE EXTERIOR LITE SHALL BE TEMPERED
TO COMPLY WITH THE SMALL MISSILE IMPACT RESISTANCE
REQUIREMENTS (FBC-2017, Chapter 24 Section 2411.3.3.7).
014 S.M.S. W/ 1 1/4'
MIN. EMBEDMENT INTO WOOD. 26
(SEE ELEVATION AT SHEET ql ,
FOR MAX. FASTENER SPACING) t/v wx INTERIOR 6 6
SHIM SPACE
INTERIOR FINISH
NOT BY LAWSON IN➢USTRIES, INC.rZ
---- m
EXT. GRADE BACK BEDDING 25 21
TO BE APPLIED BEHIND
VINDOV FRAME FLANGE BY 52X 2X - INSTALLER (TYP.)
aas�.WER,
EXTERIOR
EXT. GRADE PERIMETER
CAULKING NOT BY
LAWSON INDUSTRIES',
TO BE APPLIED BY OTHERS
C I JAMB (TYPJ
METAL LATH NAILED TO
WOOD FRAME INSTALLATION DETAIL
ALUMINUM MULLION —
SEE MULUON APPROVALS FOR
MULUON TYPE, SIZE AND MAX.
DESIGN PRESSURE LIMITATIONS.
(ALUM. 0.078" MIN. THICK)
NOTE: THE LOWER PRESSURES OF SINGLE
HUNG WINDOW OR MULL SHALL GOVERN
INTERIOR
LOCK (LATCH AND SWEEP) OPTIONS
1. BOTH EXTRUDED ALUMINUM AND PLASTIC LIFT HANDLE
LOCKS ARE QUALIFIED FOR USE ON ALL WINDOWS.
2. BOTH DIE CAST AND NYLON CAM LOCKS ARE QUALIFIED
FOR USE ON ALL WINDOWS.
3. TWO (2) LOCKS ARE REQUIRED PER EACH VENT.
-0 12 X 3/4' S.D.S.
SEE MULLION APPROVALS FOR
FLAT HEAD, PHILLIPS.
MULLION TYPE, SIZE AND MAX.
(SEE ELEVATION AND
DESIGN PRESSURE LIMITATIONS.
DP TABLES FOR QUANTITY
INTERIOR NOTE: THE LOWER PRESSURES OF SINGLE
AND FASTENER SPACING)
1/4' MAX. HUNG WINDOW OR MULL SHALL GOVERN
FSHIM
# 12 S.D.S. X 1 1/4' L.
WSJ / SEE ELEV. FOR SPACING
i NOTE: E o �q E E o
1. ALL STEEL IN CONTACT WITH
1-'-"-' - ALUM. TO RE PAINTED OR PLATED. o
_ _ _ _ _ - 2. METAL STRUCTURES: v c v W
»- A) STEEL : Fy - 36 K51 MIN. •¢ c x Q .9 o x
(STEEL 18 GA. MIN. THICK - 0.048") 5 rc ¢ rc gg
EXTERIOR PERIMETER WINDOW FRAME B) ALUMINUM : 6063-T5 MIN. x d o d c W k B
EXTERIOR O SEALANT (ALUM. 0.078- MIN. THICK) v
EXTERIOR GRADE E�+
PERIMETER CAULKING a a a
FRAME MULLING DETAIL METAL STRUCTURE ATTACHMENT DETAIL
PRODUCT REVISED
as complying with the Florida
Building Code
NOA-No. 20-0813.07
Expiration Date 12/2712026
Dy �J
Miami -Dade Product Control
W
W
w
w
K
N
(O
N
0
O
Coto
fD
N
Orl)
K)
b
N O
m'
-N wN
O
m
tNJ
N N
m
N W
m"
N W
U1
N
N
Cn
N
N
D7
N
V
lP
N
N
co
N
-4cn
lr
N
X
m
N
V
m N
N V
m N
m
N
N V
m N
Co
N
N �l
m
(T
CT
011
U)
CT
(n
CT
=
(/)
m
m
m
m
m
m
m
s
z
0
O
Z
=
v z
= 0
m m
m 0
m m
V
V
V
V
V
m
000000tn�
t`
V
O�
V
V
W
V
QD
A
N
A
N
A
N
A
N
A
N
p)
W
07
W
O
W
O)
W
O
W
O
W
(h
O
Ul
tD
CT
O
C)1
tD
CT
(O
(.TI
O
^^
YI
O
n
V
m
v v y
m m m
A A
N N
A A
N N
m m
W W
m m
W W
m m
W W
m m
W [Lf
m m
W W
m m
!D m
n
n
m m
m m
p
D A
D
y
V
C d
co
co
rn
m
3 as
n
m
m
m
m
m
3 xt cAi
0 cr
o v y
`�-
m
mmmm
(D
O
O
O
m
O
m
O
m
O
mm
O
O
m
O
m
O
mmmm
O
CD
O
O
m
O
m
O
mmol
O
O
O
rn
O
A
mmmm
m
0 0 0
mmmmmmmmmm
0 o
O O
o 0
0 0
0 0
mmmmmm
0 0
o 0
0 0
mmmmmm
0 0
0 0
0 O
A N
0
0
0
CD
0
0
0
0
0
0
CD
0
0
0
0
0
0
0
(D
0
0
C
o
0 0 0
0 0
0 0
0 0
0 0
0 0
6600.0
0 0
0 0
0 0
<_
RCI
a m
}
4
cC
c�
Z
0
b
m
O
m
-4
�o
o0......
0C)
00000
o
as
0
o
CD
auw
0000
o
00
o
00000
w
aow
au
co
Cl
N �
p
Vmmmmmmmmmmmmmmmmmmmmmmmmm
tp0000000000000000000000000p,i�
0
0
CD
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
O
K
1
o
0 0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
y
a
•p
�
z
v
A.
v x
G)
m
H m
r,co,O
O
O
O
O
c
O
c
O
003c000
O
O
O
O
O
0o,0
O
O
O
ca,o,c
O
O
O
O
0��
O
O
O
t0N�1
O) N
Z
�mmmmmmmmmmmmmmmmmmmmmmmmm
m
O 000000000000000000000.000
ply Z
O
O
O
0
0
0
0
O
o
0
0
0
0
0
0
0
0
0
0
0
0
y
o
0 0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0
0 0
V
a
m
C
I
n
0
a
o
N
x1
x1
I
W
d
C
0
G+1
C
E.IJ
Em
d
m zm�y
x D-.0 m
3
°
� ao O
1
o ?ma C
y
p
'd om
O
c
j
N O SC
fJ E2 �N
t7
7
` W o m
N 0 � �
a
N V S
IL
O)
PROFESSIONAL ENGINE
FL LIC. # 55225
N
N
N
f0 W
m N
N
v
tD W
co N
N
V
fD W
Co N-4
N
o'
f0 W
Co N
N
-4
!O •tm.1
c. N
N
v
fp W
co N
N
v m
tp
v
co
m
N N
m m
m
N N
m m
m
N N
m m
m
N N
m m
m
N N
m m
m
N N
m m
m
N=
m
Z
V
V V
A
V V
A
V
A
m
0
m m
0 0
m m
0 0
m W
0 O)
W W
m m
W W
00 W
W
=
G
C 0C
G
V V
m m
V V
m m
V A
m N
A
tJ N
A
!J tJ
m
N W
m m
W W
m m
W W
m m
W W
m m
W m
m m
W m
m
W m
m m
m m
m W
W W
W W
-4
N
W m
-4
N N
m m
N N
m m
N
m
m
m m
m m
m
N
N
N
d
m
00
m
m
m
A
A S
0
3 #
tr
°m
O y
"4 V
m m
O O
m V
O A
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 O
m m
O O
m m
O O
co
O N
tR Z
(O
fD o
A
-4 -4m
fp
m
0 0
m
0
m m
0 0
m m
0 0
m m
0 0
m m
o O
m m
o 0
Co m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0
m m
0 O
m m
O O
m m
O O
m m
o 0
m m
0 0
m m
0 0
m
0 W
A
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
00
0
T
A
m
0
m
0
m
0
m
0
mmmm
0
m
m m
m m
m m
m m
m m
m m
m m
m m
m m
m m
0) A
xi\
0
0'
00
0
0 0
0'
0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0
1
A
b
a r
t5
d
m
m
o
m
o
m
o
mmmm
o
0 0
0
mmmm
o
0 0
m
0 0
Co Co
0 0
Co m
0 0
m m
0 0
m m
0 0
Co m
0 0
m m
0 0
m m
0 0
m m
0 0
m
o p,
�i 2
o
O
O
i
O
i
O
i
0000
O
tatdn
N y
m
D
m
o i
m
0
m
0,
mmmm
0
0 0.0
mmmm
O
O O
mmmm
O O
O o
m
O O
m m
O 0
m m
0 0
m m
0 O
m m
O O
m m
o O
m m
0 O
m
o m
a
ID
V
m m
m m
m m
'O
m m
m m
m m
0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m m
0 0
m
0
tR
f0
0 0
0 0
0 0
0 0
0 0
O
0 0
O o
0 0
0 0
0 0
0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
V
0
a
N
NWs
B. Revised to Comply w 2010 FBC
m
�/ Illll 8501 N.W. 90 ST.
L xtl� S O MEDLEY, FLORIDA 33166
INDUSTRIES, INC. PH No. (305) 696-8660
MANUFACTURER OF QUALITY ALUMINUM WINDOWS AND GLASS DOORS
4
B. Revised to Com I w 201FBC
C. Compliance w/ FBC 5l� Edition (zo14)
end ASTM E1300-os
D. Revised to Comply W/ 2017 FBC
E.Revised to Com W 2oio FBC
e N. ERAzO
D'L0s z7-09
SERIES-7700 SINGLE HUNG FLANGE FRAME IMPACT WINDOW
w
N. Erflzo
ow
07/31/ Nw20
1/
DESIGN PRESSURE CHARTS, & CONFIGURATION OPTIONS
LavrL• E
Sow4:
Prodvat Bf—. N,.w . a'e.�, Nv — L7700-0901 stir 4 OF 5 Rni4bn
FRAME HEAD
L-7701
O
.500 F.062
i Etc
2.651�-
( 80G9-T5 ALU1@N1i )
FRAME SILL
L-7702
FIXED MEETING RAIL
L-7704
C
FRAME JAMB
L-77C'
O
VENT INTERLOCK RAIL VENT BOTTOM RAIL
L-7705 L-7706
O( GOBS -TB ALVblINllx ) O ( 6063_T6 ALUMINUM )
VENT JAMB RAIL
L-7707
O( 6063-T6 ALUMINUM )
�1.375�
062 1.II 5
VENT SPRING LATCH GLAZING BEAD GLAZING BEAD GLAZING BEAD
L-7539 L-7708 L-7711 L-4204
O O 16 17
.062 ( GOB3-76 ALUIO R ) ( 6083-T5 ALUllMUM ) ( 8003-T� ALUMINUM
} ase --1
— soa
1.013 L
.391
1—II .698 J466
( M63-T5 AU/MU )
t O
I FRAME TOP CORNER
9
I
I
I
I
I FRAME HEAO
FRAME JAMB
FR MF SILL ( r�
FRAME BOTTOM CORNER
� O•�• 3
�• VENT TOP CORNER
9 4
VENT JAMB RAIL
VEM T01 RAIL
O
VENT BOTTOM CORNER
FRAME & SASH CORNER DETAILS
BILL OF MATERIALS
ITEM #
PART #
REQD.
DESCRIPTION
REMARKS
1
L-7801
1
FLANGE FRAME HEAD
6063-T6 ALUMINUM
2
L-7802
1
FLANGE FRAME SILL
6063-T6 ALUMINUM
3
L-7803
2
FLANGE FRAME JAMB
6063-T6 ALUMINUM
4
L-7704
1
FRAME FIXE➢ MEETING RAIL
6063-T6 ALUMINUM
5
L-7705
1
VENT MEETING (TOP) RAIL
6063-T6 ALUMINUM
6
L-7706
1
VENT BOTTOM (LATCH) RAIL
6063-T6 ALUMINUM
7
L-7707
2
VENT JAMB (SIDE) RAIL
6063-T6 ALUMINUM
8
L-7708
AS REQD.
GLAZING BEAD C 3/8' )
6063-T5 ALUMINUM
9
FS-006
AS REQD.
FRAME ASSEMBLY SCREWS
#8 X 3/4' P.H. PHILLIPS
10
FS-040
AS REQD.
INSTALLATION SCREWS
#14 X 1 1/4' F.H./PHIL,
11
L-7531
AS REQD.
BULB VINYL WTST
1/4' DIA. BULB #3033
12
PWS-003
AS REQ'➢.
FIN SEAL WEATHERSTRIP
,187'x.230'
13
PWS-005
AS REQ'D.
FIN SEAL WEATHERSTRIP
.187'x.350'
14
PWS-009
AS REQD.
FIN SEAL WEATHERSTRIP
.187'x.310'
15
HC-024-1
2
SELF ADHESIVE PILE PAD
1/4' X 1 1/2'
16
L-7711
AS REQ'D.
GLAZING BEAD/ INSULATED
6063-T5 ALUMINUM
17
L-4204
AS REQD,
GLAZING BEAD - RADIUS
6063-T5 ALUMINUM
18
L-7723
1
SASH BALANCE CAM/GUIDE
(2 X VENT)
19
L-7725
2
RIGID VINYL SASH STOP
C2 X FRAME)
20
L-7727
2
BLOCK & TACKLE BALANCE
BSI Balance Systems
21
L-7539
2
VENT LIFT LATCH
6063-T5 ALUMINUM
22
L-7523
1X LATCH
VENT LATCH SPRING
STAINLESS STEEL
23
x
AS REQD.
GLAZING SILICONE
SEE GLAZING @ SHT. 3
24
x
2
Laminated Glass
SEE GLAZING DETAILS
25
HC-057-Ij
2
VENT LIFT LATCH
MOLDED NYLON
26
HC-058-1
2
VENT SWEEP LATCH
MOLDED NYLON
27
■
2
FRAME SILL FOAM GASKET
SELF ADHESIVE
28
HC-026-1
1
SCREEN FRAME & MESH
29
L-7730
1
PRODUCT LABEL
30
X
x
A
X
31
SM-5504
AS REQD.
JOINT SEALANT
SM-5504
32
x
AS REQ'D.j
PERIMETER ACRYLIC CAULK
OSI POLYSEAMSEAL
PRODUCT REVISED
as complying with the Florida
Building Code
NOA-No. 20-0813.07
Expiration Date 12/27/2026
By 11-- '
Miami -Dade Product Control
cw8.2
PWG
W
u �o-H
I
z
z
2 d
m u `o
c w
w
Z.
i �•