Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NOA # 20-0901.11
MIAMbDADE MIAMI—DADE COUNTY, FLORIDA PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Lawson Industries, Inc. 8501 NW 90" Street Medley, FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami —Dade County RER—Product Control Section to be used in Miami —Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami —Dade County Product Control Section (In Miami —Dade County) and/orthe AHJ (in areas other than Miami —Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incurthe expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to rev oke this acceptance, if it is determined by Miami —Dade County Product Control Sectionthat this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Bu ilding Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "LaPorte 'W-0" Outswing Glazed Aluminum French Doors — L.M.I. APPROVAL DOCUMENT: Drawing No.FD-2003RevH, titled "LaPorte —Impact French Out —Swing Door", sheets 01 through 06 of 06, prepared by the manufacturer, dated 12/12/02 and last revised on AUG 03, 2020, sign ed and sealed by Thomas J. Sotos, P. E., bearing the Miami —Dade County Product Control Section Revision stamp with the Notice of Acceptance number and Expiration date by the Miami —Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant Limitations: 1. See Design Pressure (DP) charts VS door sizes and glazing in sheet 2. See lock option VS DP in sheet 3. 2. See glazing details in sheet 5. For the glazing detail #2 (The 1 /8 temp lite is oriented at exterior side in insulated laminated glass make-up). 3. Applicable door egress requirement to be reviewed by Building official LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami —Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of thisNOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision o r change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product; for sales, advertising or any otherpurposes shall automatically terminate this NOA. Failure to comp lywith any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami —Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA#18-0503.06 and consists of this page 1 and evidence pages E-1, E-2, E-3, E-4 and E-5, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq I. Chanda, P. E. 1s"7 1- APPROVED NOA No. 20-0901.11 Expiration Date: June 05, 2023 Approval Date: December 17, 2020 Page 1 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. Evidence submitted in previous files A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under previous NOA No. 11-0202.03) 2. Drawing No. FD-2003, titled "La Porte —Impact French Out —Swing Door", sheets 01 through 06 of 06, prepared by the manufacturer, dated 12/12/02 with the latest revision "G", dated 04/15/15, signed and sealed by Thomas J. Sotos, P. E. B. TESTS 1. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked —up drawings and installation diagram of aluminum Outswing French door, prepared by Hurricane Engineering & Testing, Inc., Test Reports No. HETI-11-3201, issued on 01/06/2011, signed and sealed by Candido F. Font, P. E. (Submitted under NOA No. I1-0202.03) 2. Test reports on: 1) Uniform Static Air Pressure Test, per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked —up drawings and installation diagram of aluminum Outswing French door, prepared by Hurricane Engineering & Testing, Inc., Test Reports No. HETI-09-2623, HETI-09-2645, HETI49-2624 and HETI-09-2646, issued on 10/22/2009, signed and sealed by Candido F. Font, P. E. (Submitted under NOA No.10-0128.04) 3. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per FBC 2411 3.2.1 and TAS 202-94 along with marked —up drawings and installation diagram of aluminum Outswing French door, prepared by Hurricane Engineering & Testing, Inc., Test Reports No.'s HETI-04-1897, BETI-04-1896 A, HETI-04-1896 B and HETI-04-1377, issued on 03/08/04 and 03/12/04, all signed and sealed by Rafael E. Droz—Seda, P. E. (Submitted under NOA No. 04-0607.04) 4. Test reports on: 1) Tensile Test, per FBC, ASTM E-8 along with marked —up drawings and installation diagram of aluminum Outswing French door, prepared by Hurricane Engineering & Testing, Inc., Test Reports No. HETI-02—TO95 and HETI-02—T090, issued on 01/13/03, both signed and sealed by Rafael E. Droz—Seda, P. E. (Submitted under NOA No. 03-0219.01) Ishaq I. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0901,11 Expiration Date: June 05, 2023 Approval Date: December 17, 2020 E-1 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (coNuNUED) 5. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 along with marked —up drawings and installation diagram of aluminum Outswing French door, prepared by Hurricane Engineering & Testing, Inc., Test Reports No.'s HETI-02-1253, HETI-02-1726, HETI-02-1728, HETI-02-1736, HETI-02-1742, HETI-02- 1763 and HETI-02-1765, issued on 01/14/2003, all signed and sealed by Rafael E. Droz— Seda, P. E. (Submitted under NOA No. 03-0219.01) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC, prepared by the manufacturer, dated 12/12/02 with the latest revised dated 07/02/10, signed and sealed by Thomas J. Sotos, P. E. (Submitted under NOA No.10-0128.04) 2. Glazing complies with ASTM E1300-98/ 04 D. QUALITY ASSURANCE 1. Miami —Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No.14-0916.10 issued to Kuraray America, Inc. for their "Kuraray PVB Glass Interlayer", expiring on 12/11/16. 2. Notice of Acceptance No.14-0916.11 issued to Kuraray America, Inc. for their "Kuraray SentryGlas® Interlayer", expiring on 01/14/17. 3. Notice of Acceptance No.14-0423.15 issued to Eastman Chemical Company (MA) for their "Saflex CP — Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 06/19/14, expiring on 12/11/18. F. STATEMENTS 1. Statement letter of conformance to, no financial interest and compliance with the FBC 5th Edition (2014), dated 09/02/14, signed and sealed by Thomas J. Sotos, P. E. 2. Statement letter of conformance, no financial interest and compliance with the FBC- 2010 and AAMA 101/ I.S.2-97, dated 01/25/12, signed and sealed by Thomas J. Sotos, P. E. (Submitted under previous NOA No. 12-0127.23) 1 s�G� f • Ll�n�, Ishaq I. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0901,11 Expiration Date: June 05, 2023 Approval Date: December 17, 2020 E-2 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS (CONTINUED) 2. Proposal issued by Product Control, dated 07/27/10, signed by Ishaq Chanda, P. E. (Submitted under NOA No. I1-0202.03) 3. Laboratory compliance letter for Test Report No. HETI-11-3201, issued by Hurricane Engineering & Testing, Inc., dated 01/06/11, signed and sealed by Candido F. Font, P. E. (Submitted under NOA No. 11-0202.03) 4. Proposal issued by Product Control, dated 03/26/09, signed by Renzo Narciso. (Submitted under NOA No.10-0128.04) 5. Laboratory compliance letters for Test Reports No.'s HETI-09-2623, HETI-09- 2645, HETI-09-2624 and HETI-09-2646, issued by Hurricane Engineering & Testing, Inc., dated 10/22/09, signed and sealed by Candido F. Font, P. E. (Submitted under NOA No.10-0128.04) 6. Laboratory compliance letter for Test Reports No.'s HETI-04-1897, HETI-04-1896A, HETI-04-1896B, HETI-04-1377, HETI-02—T095, HETI-02—T090, HETI-02-1253, HETI-02-1726, HETI-02-1728, HETI-02-1736, BETI-02-1742, HETI-02-1763 and HETI-02-1765, issued by Hurricane Engineering & Testing, Inc., dated 01/14/03 and 03/08/04, all signed and sealed by Rafael E. Droz—Seda, P. E. (Submitted under previous NOA No. 05-1116.06) 1. Notice of Acceptance No. 13-0328.11, issued to Lawson Industries, Inc. for their Series "La Porte 8'-0" Outswing Aluminum French Doors — L.M.I.", approved on 06/06/13 and expiring on 06/05/18. 2. New Evidence submitted. 1. Drawing No. FD-2003 Rev G, titled "La Porte —Impact French Out —Swing Door", sheets 01 through 06 of 06, prepared by the manufacturer, dated 12/12/02 and last revised on Nov 21, 2017, signed and sealed by Thomas J. Sotos, P. E. Note: This revision consists of editorial changes of FBC 17 (61h Edition) code compliance and update of glazing interlayer. B. Test 1. None. C. CALCULATIONS 1. None D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). Ishaq I. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0901,11 Expiration Date: June 05, 2023 Approval Date: December 17, 2020 E-3 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No.14-0916.11 issued to Kuraray America, Inc. (Former E.I. DuPont DeNemours) for the "Sentry Glass ® clear & white interlayer", expiring on 07/04/18. 2. Notice of Acceptance No.16-1117.01 issued to Kuraray America., Inc. for their "Trosifol Ultraclear, Clear and Color PVB Glass Interlayers", expiring on 07/08/19. F. STATEMENTS 1. Statement letter of conformance to FBC 2017 (61h Edition) and "No financial interest" dated 11/17/17, prepared by the manufacturer, signed and sealed by Thomas J. Sotos, P.E. G. OTHER 1. This NOA revises # 14-0908.07, expiring 06/05/18. 3. Evidence submitted in previous NOA. A. DRAWINGS 1. Drawing No. FD-2003 Rev G, titled "La Porte —Impact French Out —Swing Door", sheets 01 through 06 of 06, prepared by the manufacturer, dated 12/12/02 and last revised on Nov 21, 2017, signed and sealed by Thomas J. Sotos, P. E. Note: This revision consists of "No change". B. Test 1. None. C. CALCULATIONS 1. None D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS (submitted under file #17-1212.09) 1. Statement letter of conformance to FBC 2017 (6th Edition) and "No financial interest" dated 11/17/17, prepared by the manufacturer, signed and sealed by Thomas J. Sotos, P.E. 2. Lab compliance as part of the test report. G. OTHER 1. This NOA renews NOA #17-1212.09, expiring 06/05/23. Ishaq I. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0901,11 Expiration Date: June 05, 2023 Approval Date: December 17, 2020 E-4 Lawson Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 4. New Evidence submitted. A. DRAWINGS 1. Drawing No. FD-2003 Rev H, titled "La Porte —Impact French Out —Swing Door", sheets 01 through 06 of 06, prepared by the manufacturer, dated 12/12/02 and last revised on AUG 03, 2020, signed and sealed by Thomas J. Sotos, P. E. Note: This revision consists of FBC 2020 update note. B. Test 1. None. C. CALCULATIONS 1. None D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No.17-0808.02 issued to Kuraray America, Inc. (Former E.I. DuPont DE Nemours) for the "Sentry Glass ® clear & white interlayer", expiring on 07/04/23. 2. Notice of Acceptance No.19-0305.02 issued to Kuraray America., Inc. for their "Trosifol Ultraclear, Clear and Color PVB Glass Interlayers", expiring on 07/08/24. F. STATEMENTS 1. Statement letter of conformance to FBC 2020 (7th Edition) and "No financial interest" dated 08/03/20, prepared by the manufacturer, signed and sealed by Thomas J. Sotos, P.E. 2. Lab compliance as part of the test report. G. OTHER 1. This NOA revises NOA #17-1212.09 and updates to FBC 2020 (TI Edition), expiring 06/05/23. 15t -7 l - L4gn-)'e, Ishaq I. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0901,11 Expiration Date: June 05, 2023 Approval Date: December 17, 2020 E-5 DESCRIPTION FRAME HEAD FRAME SILL FRAME JAMB SIDELITE JAMB ADAPTER PANEL TOP 6 BOTTOM RAIL HINGE STILE LOCK STILE TOP 6 BOTTOM RAIL ADAPTER 1/4 ROUND ALUM. BEAD - 7/16' 1/4 ROUND ALUM. BEAD - 3/8' HINGE LEAF ASSEMBLY Bulb Vinyl Wts'p: Team Plastics, 1 WTS'P. a TOP/BOTT. RAILS WTS'P. a FRAME HEAD 4 JAMB STRIKER MOUNTING PLATE STRIKER PLATE GLAZING ADAPTER DELTA FLUSH BOLT DOOR LOCK / BEAD BOLT SET DOOR LOCK / DEAD BOLT SET DOOR LOCK / DEAD BOLT SET Frame Install. Screw - Head Fran. Install. Screw- Jamb/Slit FRAME ASSEMBLY SCREW JAMB ADAPTER SCREW 1/4 ROUND ALUM. BEAD - II/16' GLAZING ADAPT. ATTACH. SCREW Double Rail Assembly Screw NEUTRAL CURE SILICONE NEUTRAL CURE SILICONE NEUTRAL CURE SILICONE Laminated Glass see Pg. 5 Laminated Glass see Pg. 5 Laminated Glass see Pg. 5 PANEL ASS'Y ALUM. PLATE Panel Ass'y Full Lenght Rod HINGE ATTACHMENT SCREW SIDELITE ATTACHMENT SCREW 1/2' Din. Hole Plug - Nylon 6-6 7/8' Dla. Hole Plug - Nylon 6-6 FLUSH BOLT Sill Plug - Nylon 6- 1/2 ROUND FALSE ALUM. MUNTIN INT FALSE APPLIED MUNTIN FRAME HEAD SHEAR PLATE FRAME LOW SILL - OPTIONAL TWO -POINT FLUSHBOLT LOCK FLUSH BOLT GUIDE ALUM. ANGLE 2-Point Lock Bolt Guide ANGLE Joint Sealant- White Colored LOCK ACTIVE HANDLE 6 TRIMSET MULTI -POINT LOCK ACTIVE LOCK PASSIVE HANDLE 6 TRIMSET MULTI -POINT LOCK PASSIVE Multi -Point Lock Bolt Guide Bolt Guide Attachment Fastener Lock Top Mount Adapter Lock Bottom Mount Adapter REMARxs I 6063-T6 ALUMINUM PRODUCT REVISED 6063-T6 ALUMINUM as complying with the Florida Building Code 6063-T6 ALUMINUM NOA-No. 20-0901.11 6063-TS 6063-T6 ALUMINUM ALUMINUM Expiration Date0610512023 6063-T6 ALUMINUM By 6063-T5 ALUMINUM 6063-TS ALUMINUM 6063-T5 ALUMINUM 6063-T5 ALUMINUM See Material Composition at Sheet Schlegel FS - .187'w. X .210'h. Schlegel PB - .187'w. X .330% 6063-TS ALUMINUM 6063-T5 ALUMINUM 6063-T6 ALUMINUM (e TOP 6 BOTTOM OF LOCK STILE) KWIKSET - Series 690T COMBO SCHLAGE - Series FB350 COMBO DEFIANT - Series 831 COMBO (See Notes at sheet 4 of 6) (See Notes at sheet 4 of 6) Olt X 3/4' PH. -PHI. 910 X 3/4' P.H.-PHI. 6063-75 ALUMINUM we X 1 1/4' FH.-PHI. 3/8'x2 1/4' Hex Screw 6 Nut Dow Corning 899 Tremco S-500 Dupont - Sentry Glass Plus Dupont - PVB Saflex - PVB 1 1/2'. 21x 1/8' (6063-T5 ALUM.) 3/8'Dla.-20D Rod, Plate, Flange Nut 010 X 3/4' P.H. / PHI. O10 X 1' PH/PHIL. - (17' OC Max.) MICROPLASTICS - Rockwell M-79 MICROPLASTICS - Rockwell M-79 SUNCOPLASTICS Inc. Rockwell M-79 125' X .022' STOCK ALUMINUM 6063-T5 ALUMINUM - 4- long 6063-T5 ALUMINUM OPTIONAL ( FOR 4/- 76,0 psf DP) 1 1/2'x I I/21x 118' Alum. 6063-T5 3'x 3'x I I/2'x 1/8' Alum. 6063-TS 'Purvis Co.' Super Seal ASHLAND OW5201A-A ASHLAND NW5110-STACT5 ASHLAND NW52OIA-P ASHLAND OW5110-STPAS4 NYLON 6-6 Rockwell M scale 79 O6 x 1/2' P.H./PHIL. NYLON ADAPTER NYLON ADAPTER 5' OTE 145 1/2' Max Unit Width Sidellte s e anchor spacing Swing Panel Width as sill Panel Width C 33 13/16' O ( 35 3/16' Ina., Sidelite ANCHOR NOTES: 5 P/4- max, o.c. 1. SEE ELEVATION AT SHEET 1 OF 6 FOR (at sidelite) ANCHOR O.C. MAX. SPACING AND LOCATIONS. 2. SEE SHEET 4 OF 6 FOR INSTALLATION FASTENERS TYPES. 3. SAME ANCHOR SPACING 0 FRAME HEAD & SILL. NOTESZ 1). QUALIFIES SINGLE & MULTIPLE PANELS (SEE ELEVATIONS). 2). QUALIFIES UNITS WITH AND WITHOUT SIDELITES 3). MAX. FRAME SIZE 146 1/2"w. X 95 3/4"h. OXXO 4). EXT & INT FALSE COLONIAL MUNTIN APPLIED W/SILICONE. 5). QUALIFIES SINGLE OR DOUBLE BOTTOM RAILS 6). MAX. DAYLITE OPENING WIDTH = 25" 7). MAX. DAYLITE OPENING HEIGHT = 83 1/8" 8). SEE ELEVATION AT SHEET lof6 FOR MAX. ANCHOR SPACING 9). ALL DIMENSIONS SPECIFIED ARE IN INCHES 10). NO HURRICANE SHUTTERS ARE REQUIRED FL, LIC. -55225. .Cv �r �p E 2�5 ".�7 o-,ry71G 2OZO rr Revision Notes: C) Revised to comply t added Insulated GIs D Ashland Mult-Point E Revised to complyt F Revised to comply 1 G Revised to comply III Revised to comply •"'IJ �� �r )ATE-__ ° Q i L'r i C r ;' ('„•; + • '�'°'+ lslsas:taa; X.4,d 9y: Nelson Erazo Br �� Nelson Erazo ari ns A nneu / 3 f 6 Active ie 20 u a- \ X/ Inactive d-bolt 4ock7 se+ 25' Max. DLO q// % 4- S (D W � 00 a X d / F i Side ite 1 5' 7 1 55'' 14' I-12 3/4'-I 4 1/2 4 1/2' [.- 14 1/8'-i 3/4- / 5 3/4' Cma . a{ an as (nax o.c a L/ actve panel) Innc,lve panel) NOTE: Same anchor spacing "OXXO" EXTERIOR ELEVATION at frame head & .DI NOTES: 1). THIS PRODUCT IS DESIGNED AS PER FLORIDA BUILDING CODE (2017-6th EDITION & 2020 - 7th EDITION). 2). GLASS MEETS REQUIREMENTS OF ASTM-E1300 AS PER CHAPTER 24 OF FBC CODE. 3). 1X OR 2X WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOAD TO THE STRUCTURE & TO BE REVIEWED BY BUILDING OFFICIAL. 4). ANCHORS SHALL BE AS LISTED, AND SPACED AS NOTED ABOVE AND ON DRAWING DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. 5). SEE NOTES 0 SHEET 4 OF 6 FOR INTALLATION FASTENERS TYPE. 6). ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL LIMITATIONS: 1). MAX. DP - f86 PSF W/ (4) Surface Bolts & Glass Types A, B, C & D. (SEE LOCATION DETAILS ® SHEET 3 OF 6) 2). MAX. OP = ±76 PSF W/ 2-Point Lock (active)+ (2) Surface Bolts at Inactive 3). MAX. DP = ±76 PSF W/ Flat Sill & must be used where water infiltration is not required or opening is protected by overhang ratio greater than one. 4). MAX. DP = ±86 PSF W/ Multi -Point Lock (1-active)+(1-passive) at Inactive 7 11 LA S ON MEDLEY, FLORIDAt33166 ,C INDUSTRIES, INC. (305) 696-8660 �C MANDFACTURER OF 0UALI77ALVIONUM WINDOWS AND CLASS DOORS n.f-s. NOA APPROVALI I IMPACT I FRENCH DOOR I I 1 OF 6 "La Porte" Impact" French Out -Swing Door FD-2003 I- `°°" H 110 7/8' Max Unit Width $Win SEE ALTERNATE B Pael Vidth �3P'f065 AT SHEEP C 35 3/16" max-.- I III - II A 5. Max. 12DLO 'Width S G II_D II �ji% I II H ma % I ACi;ive i% I� -- 1- - -B I II -- - -- r ,-DOUBLE RAIL®2 1 `-SEE ALTERNATE OPTIOTERNATES AT BOLT 3of 6 "OXO" ELEVATION 73 5/16' Mox Unit Vidth /-SEA PL�ERNATE LT Ponel'Width 3of 6 ( 35 3/16' nax, A N I I .0 o m� FII EII � o XQ =� lT II II s Inactive ° X a i I II Active a m j%/ 4 j% a x E B 2 145 1/2' Max UNt Width SEE ALTERNATE BOLT "PHS AT SHEET Sldellte 3 Sc+ing Panel Width Panel Width C 33 13/16, max, 1 A C 35 3/16' Max. in Max. DL Width mo 6, DII E 1 \ BII =7=/. S 0 i� II II II mo XA II II II II etive I ud w c e < o f Active 171 A II �r z II I� x• v N m 1 2 II B IF i SEE ALTERNATE BOLT OPTIONS AT SHEET Sot B "OXXO" ELEVATION ANCHOR NOTES: 1. SEE ELEVATION AT SHEET 1 OF 6 FOR ANCHOR O.C. MAX. SPACING AND LOCATIONS. 2. SEE SHEET 4 OF 6 FOR INSTALLATION FASTENERS TYPES. D. 74 1/2.' Max UMt Vidth 38 5/6, Max 38 5/8' Max �...II Unit Vidth Unit Width rrrI33� Idellte I SEE ALTERNATE BOLT SEE ALTERNATE B LT Panel Width A �1I)/ 3 T106S AT SHEET 3 oTifO6NS AT SHE 13/16' r >%. 25 Max. DL C11T a I Width I I DI I II II II H 12 I II mn% II/ / oho NT�� 3of 6 "XX" ELEVATION "OX" ELEVATION APPROVED CONFIGURATIONS NOTES: 1. ALL ELEVATIONS ARE A GRAPHICAL REPRESENTATION VIEWED FROM THE EXTERIOR SIDE. 2. FALSE COLONIAL MUNTINS ARE APPLIED W/ SILICONE AND ARE AVAILABLE AS OPTIONAL. 3. OR ELS ARE AAIILLAMBLEE WITH SINGLE BOTTOM RAIL 4. OUT -SWING DOOR WITHOUT INSECT SCREEN. C2 PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20.0901.11 Expiration Date0610512023 DpppiLJ[gg EE By 1SMZ HOTITI9M A RRRR III Miami -Dade Product Control f . 1 _ � N A II 1 II y s I I s ?d _ C2 tl Ss tL SS II XA 2� I II XQ 2� G i c II II G -0 c II II a G2 G3 �= atl� Act/ige a G 3\S as U F115e() ROUBLE Ins Ins OTTOM c' E RAIL IN I ® II II B `'-}•- ';e�, �', �c; _ �. iU -5225 A �: ± - t 10 (; 2020 1 .. r. y S_ Oj:C �r•�. �. 1 C �• W^ d �61' 'Sl .: l �' 1 'b aQdI��R1 Iauleetttn° ___ Revision Notes: C) Revised to comply w/ FBC2007 & added Insulated Glees 01 22 10 D Ashland Mult-Point Lock Ol 27 11 0 cam 1 w 2010 FBC B Revised U1.1 P Revised to comply w 2014 FBC C Revised to comply w 2017 FBC III Revised to comply w 2020 FBC Brvt••d Dy: Dab Nelson Etezo 11 01 1/1! 1'� D n- BLS Dab Dec Nelson Erazo 08/17 21 s•am n.t.e. SEE ALTERNATE BOLT SEE ALTERNATE BOLT 3PoTf06S AT SHEET t d 65 AT SHEET "X" ELEVATION "0" ELEVATION "LaPorte" IMPACT FRENCH OUTSWING DOOR - DESIGN LOAD CHART PANEL WIDTH/IBIGHT AC(1NNISSY)LE NUBBER OF ANCHORS /lam DP PANEL DP ( PSF ) GLASS TTPE "A' k 'S' +/-(PSF) ACTUAL (INCHES GLAS9 TYPE "B" +/-(PSF) GLASS TYPE 'C' +/-(PSF) GLASS TYPE "D" +/-(PSF) WIDTH • REIGRT • WDT1T1 • 10 1/4' 16 1/4' 22 1/4' 28 I/4' 30 1/4' 34 1/4' 77' xC51 5 ±86.0 11 3/16' +76.0 +76.0 ±76.0 5 +86.0 17 3/16' ±76.0 ±76.0 +76,0 5 ±86.0 23 3/16' ±76.0 +76.0 t76.0 5 ±86.0 29 3/16' +76.0 +76.0 +76.0 5 ±86.0 31 3/w ±76.0 ±76.0 ±76.0 5 ±86.0 35 3/16' ±76.0 ±76.0 ±76.0 IO 1/4' 16 1/4' 22 1/4' 28 1/4' 30 1/4' 34 1/4' 93' rC61 6 +86.0 11 3/16' ±76.0 ±76.0 ±76,0 6 +B6,0 1 17 3/16' +76.0 +76.0 +76.0 6 +86.0 23 3/16' +76.0 ±76.0 +7610 6 ±86,0 1 29 3/16' ±76.0 +76.0 ±76.0 6 ±86,0 31 3/16' ±76.0 ±76.0 ±76,0 1 6 +86,0 1 35 3/16' +76,0 +76,0 +76.0 • UP KABLt PANEL MU51 Mttl AYY11 uu HGQUIHtMtN15 PtH MILLING CUUt. • () PARENTHESIS INDICATES ® OF ANCHORS AT FRAME JAMB. LS �l..G1 V' MEDLEY,)f FLORIDAt .11 33166 INDUSTRIES, INC. (305) 696-8660 MANUFACTURER OF QUALITY ALUMINUM WLVDOWS AND CUSS DOORS OA APPROVALI I IMPACT I FRENCH DOOR 1 2 OF 6 "La Porte" Impact" French Out -Swing Door FD-2003 I"..".,"., - H 1 I/4' •5/16' TAPCON W/ 1 1/2' MIN EMBED. (SEE NOTES BELOW FOR SPACING) 2 x IRT.) WOOD BUCK / I I _1/4' MAX. SHIM TYP. 3 a,r /JAMB Sldellte MULLION DLO Width 9 11 N Panel. el Width 1 } MIN EMBED, TYP O O 18 46 INTERIOR SIDE INTERIOR SIDE Active Inactive Active Inactive O � / \ E%TERIOR 9IDE 1 1 -OR SIDE E3 L( J E4 L—J LOCK STILES WITH FLUSH BOLT LOCK STILES WITH TWO -POINT LOCK & FLUSH BOLT INTERIOR SIDE EXTERIOR SIDE 2' Sillr.�. Height T4L INTO SI CONC. (TYP.) N V/ IND ENDED. (MIN. EDGE DIST.) (SEE SHEET I OF 6 FOR LOCATION AND SPACING) B2 OPTIONAL - DOUBLE BOTTOM RAIL DETAIL PRODUCT REVISED as Complying with the Florida Building Code NOA-No. 20.0901.11 Expiration DateO610512023 By Miami -Dade Product Control INTERIOR SIDE LOCK STILE Active 1 X (P.T.) WOOD BUCK - (SEE NOTE 3, SHEET D 3 4 3 MUWON JAlIII14 Inactive O 12 O 17O 12 17 I I Sldellte E EXTERIOR SIDE O "OXXO" UNIT WIDTH 6' TWO —POINT MULTI —POINT MAX. DP - t76 PSF MAX. DP - t86 PSF OPTIONAL LOCK DETAILS PROFESSIONAL ENGINEER FL.LIC. y1 65226,E 0 55225 iiiJJ/ 1 .•, 2a2a `; h '/'d•'T'G nItET'd` # 18 # 18 Active Inactive OPTIONAL BOLT @ TOP RAIL Active Inactive ' % OPTIONAL BOLT 0 BOTTOM RAIL C SEE DETAIL E3 FOR MOUNTING LOCATION ) FLUSH BOLT & TWO -POINT LOCK LIMITATIONS: 1). MAX. DP = ±86 PSF W/ (4) Surface Bolts & Glass Types A, B, & C. 2). MAX. DP = ±76 PSF W/ 2-Point Lock (active)+(2) Surface Bolts ® Inactive -5/16' TAPCON W/ 1 1/2' MIN EMBED. SEE ELEVATION AT SHEET 1 OF 6 FOR SPACING s' •`'' 1 1/4' Minimum ^EcIn Distnnce C2 MAX SHIN —1 MIN (T ANCHOR NOTES: 1. SEE ELEVATION AT SHEET 1 OF 6 FOR ANCHOR O.C. MAX. SPACING AND LOCATIONS. 2• FASTENERS T41'POF 6 FOR INSTALLATION 5 17 EXTERIOR SIDE LINTERIOR 9IDE 5 13 I B'3 12 1/2' Sil( (*) OPTIONAL SILL Heigh A':.1 A' MIN EMBED. INTO 3500 PSI CONC. (TYP.) 5/l6' ELCO TAPCON V/ 1 1/4• 1 1/2' MIN EMBED. (MIN. EDGE DIST.) 23 (•) FLAT SILL NOTE: DOORS 4 SIDELITES WITH THIS SILL TO BE 95 1/4' MAX FRAME HEIGHT. THIS TYPE OF SILL IS LIMITED TO +/- 76.0 psf DESIGN LOAD AND MUST BE USED WHERE WATER INFILTRATION IS NOT REQUIRED OR THE EXTERIOR OPENING IS PROTECTED WITH AN EXTENDED CEILING OR ROOF OVERHANG GREATER THAN OR EQUAL TO THE HEIGHT OF THE WALL WHERE THE DOOR IS LOCATED. an Notes: evised to comply A/ FBC2007 & shed Insulated Glass Ol 22 10 77' ,1 pppp��'//,R T� Tp 7R T 1lAJL9J.1L/1JIIIII L V Pwty// `IY�L�OH/) 1 t\N\V// 8501 NW 90th St. MEDLEY, FLORIDA 33166 NDUSTRIES. INC. (305) 696-8660 MANUFACTURER OF QUALITY ALUMINUM WINDOWS AND GLASS DOORS ehland Mult-Paint Lock 01 27 11 evised to com A 2010 FHC evised to comply A 2014 FBC evleed to com l A 2017 FBC Drmo CW.: ran cm.. »•a Cabsary: s.N../AM . ]A - —L NOA APPROVAL IMPACT FRENCH DGOR S OF 6 evised to com 1 w 2020 FEW Dr. Nelson Erazo Da cn.aa•.n 11/01/17 ' ' LaPorte" Impact" French Out —Swing Door Br: Dan Drawn• Nelson Erazo 06/17/20 S-4. n.t.e. R.Jmfw. Number D'a"A'e A'itn _ FD-2003 RwANan Lrv.t H 5/1 TAPCON W1 I I MIN EMBED. SEE BELOW FOR SPACING INTERIOR SIDE I x (P.T.) WOOD BUCK 3 (SEE NOTE 3, SHEET 1) 3 JAMB AMD 19 20 21 LOCK STILE 46 23 6 7 (15) Active InoctiveST 615T. 'E KEDGE DI 17 18 Y P.* 27 12 1/4' MAX SHIM ..NXII (MIN. EMBED.) UNIT WIDTH MIN EMBED EXTERIOR SIDE (TYP.) lrnoe -T. TYP. — 5/16' TAPCON W/ 5/16' TAPCON W1 LOC I 1 112' MIN EMBED. 1 1/4' MIN. 7�.<SEE NOTES FOR SPACING) EDGE DIST 1 1/2' MIN EMBED. SEE NOTES FOR SPACING TYP le. TO;— 2x P.T. 'x BUCK (SWO. BUC C (SEE 1 1/2 ;EMBI.N I x (PT) WOOD BUCK (SEE 46iE 3, SHEET 1) 29 30 31 MIN. EMBED NO NOTE 3, AT _T EM TYP TYP SHEET 1) SHEET r Active Active (D-- 1/4M MAX. MAX, SHIM TYP, HEAD TYP. HEAD22 FSHI 44 9 10 13 22 FS (X) 8 12 EXTERIOR SIDE S t AI1;1.6L.-t Screw Q_ c,, s crews .. Ids of jambs, 12 totmi, per sideUte INTERIOR SIDE GLASS 0 7� Tj Lo I = L; W _j LO EXTERIOR SIDE W z z < CL INTERIOR SIDE 042 P 17' H.., DC. 17 EXTERIOR SIDE 5 5 213 12 12 21 O 3 1 23tj 1 2� 11 t 2. Slit SILL ?h't ... Height 1 MIN EMBED SILL •: Igh t • '.". I J'.MIN EMBED, INTO TYP - m, 3500 PSI CONC. 5/16' ELCO TAPCON W/ (TYP.) I / ' MIN EMBED. 2SHEET 1 1/4' (MIN. EDGE DIST.) 1/4 (SEIE I OF 6 FOR SPACING) (MIN. EDGE DISL) Active I x (P.T.) WOOD BUCK (SEE NOTE 3, SHEET 1) INTERIOR SIDE LOCK STILE /QJAMB IRA: 37 9 10 36 27 ' • O EXTERIOR SIDE STILE ©� (@ MULLION INTERIOR SIDE 12 SIdelite V INTERIOR SIDFf E LOCK STILE W /0 Inactive 5/16' TAPCON W1 1 1/2' MIN EMBED. SEE ELEVATION AT SHEET I OF 6 FOR SPACING INTERIOR SIDE LOCK STILE 7 Active (EDGE DIST) =k,-5;j TYP. 12 EMLED.) L J TYP. EXTERIOR SIDE INTERIOR SIDE Active LOCK STILE EXTERIOR SIDE INSTALLATION FASTENERS NOTES: '1X BUCK' MINIMUM REQUIRED FASTENER LENGTH HEAD: 5�16: X 3 1/2" Long TAPCON(*? JAMB: 5/16" X 2 3/4" Long TAPCON -) MULLIONS: 5/16" X 2 1/4" Long TAPCON(-) 0) TAPCON BY "ELCO ULTRACON "9X RUCK' MINIMUM REQUIRED FASTENER LENGTH HEAD: 5/16" X 3' Long TAPCON(-) JAMB: 5/16' X 2 1/4 Long TAPCON(-) MULLIONS: 5/16" X 2 1/4" Long TAPCON(-) 011 TAPCON BY "ELCO ULTRACON' AT SILL, 5/16" TAPCON w/ 1 1/2" MIN. EMBED, INTO 3500 PSI CONC. MIN. NOTE ALL FASTENERS W/ 1 1/a MIN. EMBEDMENT. 1 1/4" MIN, EDGE DISTANCE & 1 A" MAX. SHIM SPACE ANCHOR YIELD STRENGTH Fy=155ksi Q7 EXTERIOR SIDE THOMAS J. SOTOS PROFESSIONAL ENGINEER FL 13C. #.55=,. ANCHOR ULTIMATE STRENGTH Fu=177ksi TAPCON LENGTHS "L" SPECIFIED ARE MINIMUMS SEE ELEVATION AT SHEET 1 of 6 FOR ANCHOR MAX. SPACING AND LOCATIONS 1.added cii:3zko Revision Notes: vise 0 4k C) Re d to comply wl FBCZO 7 T-mlated Glass 01/22 to 8501 NW 90th St. LA WS ON MEDLEY, FLORIDA 33166 i,.T3DT_Tis-rMH:�s, INC. _) (305) 696 -8660 MANUFACTURER OF QUALrff ALUUINVZI 711MOYS AND CLASS DOORS 2 Addend 1-110 4elc OIW7 11 A 11 - %!T;�_ - - j Revised�t.mg 0,. C F) Revised to comply w/ 2014 FBC zz Revised to comply w/ 2017 FBC Mt`- -7- No APPROVAL jp� �' J�IMPACT ISFRENCH DOOR 4 OF 6 tvised to comply w/ 2020 FBC r J�ld By, D.0 0..k.d. Nelson Ereato 11/01/17 "LaPorte" impact" French Out —Swing Door aw N.1... Er=. 08/17/20 S.�` ..L.. 1..f—. N-b-. FD-2003 H .._ .._........ SIDELITC WAD' "� 12 v4 scREvs ( f ... ........ ..\ eta x 1. 1 ASSEMBLY SCREVS n28 012 a 3/1' Pll/PND.. I I WEATHERSTRIP FACE IP \ 3 IS/1 INTERIOR SIDE 17 Glazing Adapter- \ L5/6'�Glazing Depth Laminated Glass L/ --� Types "A', 'B" or "C" SILL by �(see below) ADAPTEC� 'INTERIM "' JAMB INTERIM SIDE (SEE TAHLCORRESPONDINGFRAME ASSEMBLY DETAIL SIDELITE/JAMB ATTACHMENT DETAIL GLAZINGTDESCRIPTION)1/4 Round33 34 Head 9 10 T-,(BXK ACCESSfaIE\ EXTERIOR SIDE SIDE) \IT SHOWN SILL SEALANT DETAIL NOTE, HEADER TO DE SEALED SIMILAR TO SILL ,� ^/ I LEFT DOOR \/ �HDIGE STILE EP1 BOTTOM LEFT JAMB THIEF THRE Da - HINGE ATTACHMENT" I SCREWS 031 U mo K s/4• vM/vwL SINGE ATTACHMENT )ETAILS ACCESS HOLE /- P.1 / LEFT HAND HINGE .1 To I. W STILE BOTTOM TTACNMENT NIX NUT r31 AND vasty ,• PR PHIL PANEL ASSEMBLY DETAIL ACCESS HOLE COVEF #14 SMS OR SELF DRILLING SCREWS INTO METAL STRUCTURE I114 SHE OR SELF DRILLING SCREWS INTO METAL STRUCTURE (SEE NOTES FOR SPACING) E➢GE ➢IST. ..(i.... II (603TT5MIN) (SEE NOTES FOR SPACING) 1� MIN EDGE DIST. .�Ii.� II (fy2--F'36A. MKSI MIN,) K114111 UM TUBE STEEL TUBE OR I �j ...�.._____. IMIA� OE NOpODIONry-_L TOTEEL BE PLATED OR PAIN C12NTAC 1/4' MAX. SHIM TYP, 1/4' MAY SHIM TYP. 5/16' ELCO TAKEN W/ 1 1/4' MIN, EDGE DISSTT. 1 MIN TYPE DIST, ENDED. I- TYP 5/16' TAPCGN W/ f CONC. (SEE2N TES SPACING) I (SEE2 NOTESEFORDSPACING) (GONG. TO BE 3 KSI MIN.) I 2 X CP.T.) 1 1/Y = .yam ^' 1 1�2- (MIN. MBFD ) WOOD BUCK (SEE GEN. NOTE 83) OA (MIN � NOTE, OPTIONAL INSTALLATION TD DOOR FRAME JAMB (TYP.) MAXI SHIM TYP. DETAILS HAY APPLY AND/OR FRAME HEAR FRAME INSTALLATION OPTIONAL 1/4' MAX. SHIM TYP. DETAILS GLAZING DETAIL #1 -A' - SENTRYGLASS by, Kuraray America, Inc. 'B' - TROSIFOL PVB by, Kuraray America, Inc. 'C' - SAFLEX PVB by, Eastman Chemical Co, INTERIOR SIDE 10 Glazing Adapter Glazing SYlaol 6/16" Laminated Glass 5/8 29 30 31 Types "D" or °E" 37 34 GI g De th by : (see below) (SEE TABLE W/ CORRESPON➢ING GLAZING TYPE L ➢ESCRIPTIDM - -- - - 1/4" Insulated Air Space w/ 1/8- Temp. Glass INSULATED SPACER 'TruSeal'- Glazing Bead Dura Seal SWlggle Spacer 26 Black - I/4' Alr Space PILNo, 812-25H-357 EXTERIOR GLAZING DETAIL #2 'D' - SAFLEX PVB bys Eastman Chemical Co. 'E' - SENTRYGLASS by, Kuraray America, Inc. N(NTiE NYLW( Eno PLUG— < Nm` L-S��H12 I 5/16•(a� ST 4QIl♦E�SS' STEEL Pet PRODUCT REVISED _' as complying with the Florida Building Code NOA-No. 20-0901.11 Expiration Date0610512023 R. I0-. 1 L4,n1. PROFESSIONAL ENGINEER - �0 3A. HI6E BE NIO� '' R ,128— I— li—�.sp- I - NCE°23()a - =_ ll GLAZING TYPE & DESCRIPTIONS .466" 0 A Laminated Glass by DuPont - Glass TvDe "A" ITgn DESCRIPTION DETAIL 32 1 3/16' Annenled 3/l6• ° 2 ,090' SentryGlnss Intertnyer I a4cc• 3 3/16' Annenled .340" 0 A Laminated Glass by DuPont - Glass TvPe "B" ITEM DESCRIPTION DETAIL 33 I ' oa 4 1 2 1/8' Annealed .090' TROSIFOL PVB Interloyer 3 I/8' Annealed .340 0 A Laminated Glass by So 'a - Glass Type C ITEM DESCRIPTION J_/ DETAIL 34 va• -`{t- I a341r J 1 tHeat-Strengthened Glass 2 A90990' Snflez PVB Intertnyer 3 1/e' Heat -Strengthened Glns GLAZING TYPE & DESCRIPTIONS .340" 0 A Laminated Glass by Solutia - Glass DMe D ITEM DESCRIPTION DETAIL 1 1/8' Hent-Strengthened Glass / ® .1/4• I O n J 2 3 A90' Saflez PVB ]nterlayer 1/0' Heat -Strengthened Glass 4 1/4' INSULATED AIR SPACE 5 I/B' TEMPERED GLASS .340 O A Laminated Glass !MQ Solutia - Glass DMe fi ITEM DESCRIPTION DETAIL 1 1/8' Heat -Strengthened Glnss J- © J 4' A. 11 2 ,090' SentryGlnss Interlayer 3 1/8' Heat -Strengthened Glass A9' 1.141 34 4 1/4' INSULATED AIR SPACE 5 1/8' TEMPERED GLASS 11 HINGE ASSEMBLY DETAIL #FD-624-2 ion Notes: evised to complyy w/ FBC2007 & ddedshla Insulated Glass Ol 22 10 ,A ��B T ,�1 7a T 1,L/JIIIIIIl WpWI /CNF// f. (�J��1' 1 1 @\T7/( 8501 NW 90th St. MEDLEY, FLORIDA 33166 INDUSTRIES- INC. (305) 696-8660 ATANUFACTURER OF QUALITY ALUMINUM WINDOWS AND CLASS DOORS sblsed Lock 01 27 11 ;evlsed to comply w 2010 o comply FBC 'wised to comply w 2014 FBC ,a 122e to com ] w 2017 FBC n.nW, cta..: Part cla..: r'.aa eae se.v: s..a./R.a°D te.a. MCA APPROVAL IMPACT FRENCH ODOR 5 OP 6 lavleed to COm 1 w 2020 FBC Nelson Erazo Gail%01 17 "LaPorte" Impact" French Out —Swing Door DV: Nelson Erato ➢al. a. — 08/17/20 $"". a.t.s. Fan Rw,L.r tAao(sD Ra.A°°r: I FD-2003 b w MULTI -POINT - LOCK ACTIVE ACTIVE HANDLE 6 TRIMSET . 3/8, 1 STEEL MULTI -POINT LOCK PASSIVE 0 0 '0 0 52 53 PASSIVE HANDLE s TRIMSET 0D. . BOLT U 1-`il Optional Multi -Point Locks (+/- 86.0 psf DP) OPTIONAL 48 TWO -POINT LOCK Active Lock Posslve Lock LOCK #HC-060 ASHLAND OW5130-STACT5 ASHLAND RWMIO0 STPA: (+/- 76.0 psf DP) HANDLE 4 TRIMSET HANDLE 4 TRIMSET ASHLAND NW5201A-A ASHLAND OW5201A-P FLUSH BOLT AND TWO -POINT LOCK 49 ANGLE GUIDE #FD-627-1 1.500 - 124 �1 1500 INACTIVE -PANEL FLUSH BOLT 47 ANGLE GUIDE 1 1/2" LONG #FD-625-1 I' 1 1/2' I SIDELITE PANEL ALUMINUM PLATE 35 2" LONG #HC-002 .s3a i m _1 STAINLESS STEEL BOLT 0) (e) 5/16' OIL SSS ('/- 76.0 psf) (�) 3/E' ❑A SSS (+/- 860 psf) INACTIVE -PANEL 18 FLUSH BOLT #HC-001 .076 -�I- I .875 ,062 J- 17 1.151 GLAZING ADAPTER #L-910 .119 I- II 2.031 -I 11 BINGE LEAF #L-908 10.656 L250 045J HALF ROUND 42 FALSE MUNTIN #L-913 -{ 078 50 I .460 .986 L .908 1 QUARTER ROUND 28 (11/16") BEAD #FD-634 .060 726 II- s 8080 QUARTER ROUND 10 (3/8") BEAD #L-912 070 L35�� I I_656 .808 -{--I OQUARTER ROUND (1/4") BEAD #L-911 1.625-IL0.19£ o l ORAIL ADAPTER #L-909 Flexible Vin FFVG Cumposition -Team Plastics Inc. "1. FPVC Black Compound No. 7200-75 PHYSICAL ASIM NO. D)rommr Hardres"A", 10 sec 75 D-2240 Spec'dic Grmity 1.45 D-792 Temile Sbengiki'S1 1640 D538 Ultimate Elon&itior4 % 340.0 D4638 Modulus @I00%Elmga6on, PSI 765.0 D-638 Impact Brittimess, -31.0 D-746 "2. FPVC While: Compound No. 7267-75 PHYSICAL ASTM NO. DmometerHardres"A",10sm 75 D-2240 Spwific Gravity IA5 D.792 Tewilc Sur gth,PSI 1640 D-638 Ulthnate Elonga(ioq % 325.0 D-638 Modulus@ 100% ElmlIdon, PSI 765.0 D-638 lm act BdUI_, -30.0 D-746 PROFESSIONAL ENGINEHR FL LIC. # 55225. n• Ii y•�Q_- lirm. E-- �`rPdA93t"v-'Lln°` 3.5 .096 L7so .o7a 127 4 I OPANEL HINGE STILE #L-907 TI 4,187 .098 I 1.750 .075 5.05 OPANEL LOCK STILE #L-905 I- 1.75 -I .072 j 4,000 072 - .094 - ,082 OPANEL TOP & BOTTOM RAIL #L-906 1.750 I OFRAME JAMB #L-903 NOTE: 1. ALL DIMENSIONS SPECIFIED ARE IN INCHES 2. SEE ELEVATION AT SHEET 1 OF 6 FOR ANCHOR O.C. MAX. SPACING AND LOCATIONS PRODUCT REVISED as complying with the Florida Building Code NOA-No. 20-0901.11 Expiration Date0610512023 a.' 1 s-1 I. Z ;", ", v 4.500 1. I50 k�1� .687 r .065 "I - 1.812 --I FRAME HEAD #L-901 _T 125� 1 .100 .064 '064 2.000 I 4.500 OFRAME SILL #L-902 1.812 1 1.812 -I .066 ,063 .214 J 4.500 OJAMB ADAPTER #L-904 4.346 0.078 0.058 J 4.066 44 FRAME HEAD SHEAR PLATE #L-916 2.688 ,500 LIB .300 � I4.500I 45 FRAME LOW SILL #L-916 NOTE RTO DETAIL '113' AT SHEET 0 3 OF 6 FOR ADDITIONAL NOTES AND LIMITATIONS. Remion Notes: mlam-acie rrocuct wnnol C) Revised s comply ws FBC2007 & addedInsulatedulted Glass 22 10 t ,,��yy /III `� ON 8501 NW 90th St. LA k D Aehlend Mult-Point Lock 01 27 I1 1,L111i11 P.`VJI' MEDLEY, FLORIDA 33166 INDUSTRIES, I C. (305) 696-8660 E Revised to com 19 w 2010 FBC F Revised to comply w 2014 FBC MANUFACTURER OF QUALITY ALUMINUM WINDOWS AND CLASS DOORS G Revised to comply wl 2017 PRO rare ctao.: nod ccwPo s..w/uoa.e tam - R Revised to complyw 2020 FBC NOA APPROVAL IMPACT FRENCH DOOR 6 OF 6 RMud Dr. Nelson Erazp Dah Wv"Lvd: 11/o1/L7 q "LaPorte" Impact" French Out -Swing Door Da, Nelson Erazo DOB/D'1 .20 IFu+f Nu - n.te. FD-2003 I"•'""""" `"'"` H