HomeMy WebLinkAboutEnergy Efficiency Coder
\ l
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION -
Florida Department of Business and Professional Regulation - Residential Performance WNW .
Project Name: ELIZABETH AVENUE PROJECT
Builder Name:
JUL t R 7021
Street: ELIZABETH AVENUE
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Permitting Department
Owner:
Jurisdiction: ST LUCIE COUNTY
St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. W all Types(1773.3 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1577.30 ft2
b. Frame - Wood, Adjacent
R=11.0 196.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1568.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1568.00 112
6. Conditioned floor area above grade (W) 1568
b. N/A
R= ft2
Conditioned floor area below grade (W) 0
c. N/A
R= ft2
7. Windows(233.2 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: LAUNDRY
R ft2
RM 6 150
a. U-Factor: Sgl, U=1.05 233.22 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
35.4 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 3.292 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.250
a. Electric Strip Heat
27.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric Tankless
Cap: 1 gallons
9. Floor Types (1568.0 sqft.) Insulation Area
EF: 0.990
a. Slab -On -Grade Edge Insulation R=0.0 1568.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
None
Total Proposed Modified Loads: 51.88
Glass/Floor Area: 0.149
PASS
Total Baseline Loads: 57.15
I hereby certify that the plans and specifications covered by
Review of the plans and
.� T S.
this calculation are in compliance with the Florida Energy
specifications covered by this.0',
'
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 5-4-2021
this building will be inspected for
compliance with Section 553.908
* �'
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT•
BUILDING OFFICIAL:
DATE:
DATE:
a a®-
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
5/4/2021 12:36 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020
INPUT SUMMARY GFIEGKLIST REPURT
PROJECT
Title:
ELIZABETH AVENUE PROJE
Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 1568
Lot #
Owner Name:
Total Stories: 1
Block/Subdi%ision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
ELIZABETH AVENUE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State,
Zip:
FORT PIERCE,
Family Type:
Detached
FL,
New/Epsting:
New (From Plans)
Comment:
CLIMATE
v
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
1568
15188.4
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
KITCHEN
290
2697 Yes
0
1
Yes
Yes
Yes
2
CLST 3
16
149 No
0
1
Yes
Yes
Yes
3
BEDROOM 3
152
1413.6 No
0
1
1
Yes
Yes
Yes
4
FOYER
49
504.7 No
0
1
Yes
Yes
Yes
5
GREAT RM
322
3316.6 No
0
1
Yes
Yes
Yes
6
BATH 2
35
325.5 No
0
1
No
Yes
Yes
7
HALLWAY
28
260.4 No
0
1
No
Yes
Yes
8
LAUNDRY RM
63
585.9 No
0
1
Yes
Yes
Yes
9
CLST 2
18
167.4 No
0
1
No
Yes
Yes
10
BEDROOM 2
150
1395 No
0
1
1
Yes
Yes
Yes
11
M TOILET
20
186 No
0
1
No
Yes
Yes
12
M BATH
114
1060.2 No
0
1
Yes
Yes
Yes
13
M WIC
60
558 No
0
1
Yes
Yes
Yes
14
MASTER BEDROO
235
2420.5 No
0
1
1
Yes
Yes
Yes
15
M HALL
16
148.8 No
0
1
No
Yes
Yes
FLOORS
#
Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation KITCHEN
37 ft
290 ftz
____
1 0
0
2 Slab -On -Grade Edge Insulation CLST 3 2 ft
16 ft2
____
1 0
0
3 Slab -On -Grade Edge Insulation BEDROOM 3 32 ft
152 ftz
____
1 0
0
5/4/2021 12:36 PM I EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
4 Slab -On -Grade Edge Insulation
FOYER 7 ft
49 ft2
----
1 0
0
5 Slab -On -Grade Edge Insulation
GREAT RM 14 ft
322 ft2
--_-
1 0
0
6 Slab -On -Grade Edge Insulation
BATH 2 1 ft
35 ft2
----
1 0
0
7Slab-On-Grade Edge Insulation
HALLWAY 1 ft
28 ft2
----
1 0
0
8 Slab -On -Grade Edge Insulation
LAUNDRY RM 9 ft
63 ft2
____
1 0
0
9 Slab -On -Grade Edge Insulation
CLST 2 1 ft
18 ft2
__-_
1 0
0
10SIab-On-Grade Edge Insulation
BEDROOM 2 12 ft
150 ft2
1 0
0
11SIab-On-Grade Edge Insulation
M TOILET 1 ft
20 ft2
----
1 0
0
12SIab-On-Grade Edge Insulation
M BATH 9 ft
114 ft2
----
1 0
0
13SIab-On-Grade Edge Insulation
M W IC 6 ft
60 ft2
____
1 0
0
14SIab-On-Grade Edge Insulation
MASTER BEDRO 35 ft
235 ft2
____
1 0
0
15SIab-On-Grade Edge Insulation
M HALL 1 ft
16 ft2
____
1 0
0
ROOF
v
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Composition shingles 1699 ft2
0 ft2
Medium
N
0.3
No 0.9
No 0
22.62
ATTIC
V # Type
Ventilation
Vent Ratio (1 in)
Area
FIBS
IRCC
1 Full attic
Vented
150
1568 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
KITCHEN
30
Blown
290 ft2
0.1
Wood
2 Under Attic (Vented)
CLST 3
30
Blown
16 ft2
0.1
Wood
3 Under Attic (Vented)
BEDROOM 3
30
Blown
152 ft2
0.1
Wood
4 Under Attic (Vented)
FOYER
30
Blown
49 ft2
0.1
Wood
5 Under Attic (Vented)
GREAT RM
30
Blown
322 ft2
0.1
Wood
6 Under Attic (Vented)
BATH 2
30
Blown
35 ftz
0.1
Wood
7 Under Attic (Vented)
HALLWAY
30
Blown
28 ft2
0.1
Wood
8 Under Attic (Vented)
LAUNDRY RM
30
Blown
63 ft2
0.1
Wood
9 Under Attic (Vented)
CLST 2
30
Blown
18 ft2
0.1
Wood
10 Under Attic (Vented)
BEDROOM 2
30
Blown
150 ft2
0.1
Wood
11 Under Attic (Vented)
M TOILET
30
Blown
20 ft2
0.1
Wood
12 Under Attic (Vented)
M BATH
30
Blown
114 ft2
0.1
Wood
13 Under Attic (Vented)
M WIC
30
Blown
60 ft2
0.1
Wood
14 Under Attic (Vented)
MASTER BEDRO
30
Blown
235 ft2
0.1
Wood
15 Under Attic (Vented)
M HALL
30
Blown
16 ft2
0.1
Wood
5/4/2021 12:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
Space
13-11alie
EtEt
n
Arpn1
E
Exterior
Concrete Block - Int Insul KITCHEN
4.1
25
0
9
4
233.3 ft2
0
0
0.3
0
2
S
Exterior
Concrete Block - Int Insul KITCHEN
4.1
12
0
9
4
112.0 ft2
0
0
0.3
0
3
E
Exterior
Concrete Block - Int Insul CLST 3
4.1
2
0
9
4
18.7 ft2
0
0
0.3
0
4
N
Exterior
Concrete Block - Int InsuBEDROOM 3
4.1
12
0
9
4
112.0 ft2
0
0
0.3
0
5
E
Exterior
Concrete Block - Int InsuBEDROOM 3
4.1
12
0
9
4
112.0 ft2
0
0
0.3
0
_ 6
W
Exterior
Concrete Block - Int InsuBEDROOM 3
4.1
8
0
9
4
74.7 ft2
0
0
0.3
0
7
N
Exterior
Concrete Block - Int Insul FOYER
4.1
7
0
10
4
72.3 ftz
0
0
0.3
0
8
S
Exterior
Concrete Block - Int InsuIGREAT RM
4.1
14
0
10
4
144.7 ft2
0
0
0.3
0
9
E
Exterior
Concrete Block - Int InsuLAUNDRY R
4.1
9
0
9
4
84.0 ft2
0
0
0.3
0
10
N
Garage
Frame - Wood LAUNDRY R
11
7
0
9
4
65.3 ft2
0
0.1
0.3
0
11
N
Garage
Frame - Wood CLST 2
11
2
0
9
4
18.7 ft2
0
0.1
0.3
0
12
W
Exterior
Concrete Block - Int InsuBEDROOM 2
4.1
12
0
9
4
112.0 ft2
0
0
0.3
0
13
N
Garage
Frame - Wood BEDROOM 2
11
12
0
9
4
112.0 ft2
0
0.1
0.3
0
14
W
Exterior
Concrete Block - Int Insul M BATH
4.1
9
0
9
4
84.0 ft2
0
0
0.3
0
15
W
Exterior
Concrete Block- Int Insul M W IC
4.1
6
0
9
4
56.0 ft2
0
0
0.3
0
16
E
Exterior
Concrete Block - Int InsuMASTER BE
4.1
4
0
10
4
41.3 ft2
0
0
0.3
0
17
S
Exterior
Concrete Block - Int InsuMASTER BE
4.1
14
0
10
4
144.7 ft2
0
0
0.3
0
18
W
Exterior
Concrete Block - Int InsuMASTER BE
4.1
17
0
10
4
175.7 ft2
0
0
0.3
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated LAUNDRY R
None
.23
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
E 1
Metal Low-E Single Yes
1.05
0.25
Y
15.0 ft2
1 ft 4 in
1 ft 4 in
None
None
2
S 2
Metal Low-E Single Yes
1.05
0.25
Y
15.0 ft2
1 ft 4 in
1 ft 4 in
None
None
3
N 4
Metal Low-E Single Yes
1.05
0.25
Y
30.0 ft2
1 ft 4 in
1 ft 4 in
None
None
4
N 7
Metal Low-E Single Yes
1.05
0.25
Y
48.0 ft2
9 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
5
S 8
Metal Low-E Single Yes
1.05
0.25
Y
48.0 ft2
1 ft 4 in
1 ft 4 in
None
None
6
W 12
Metal Low-E Single Yes
1.05
0.25
Y
20.0 ft2
1 ft 4 in
1 ft 4 in
None
None
7
W 14
Metal Low-E Single Yes
1.05
0.25
Y
9.0 ft2
1 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
8
E 16'
Metal Low-E Single Yes
1.05
0.25
Y
18.2 ft2
5 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
9
W 18
Metal Low-E Single Yes
1.05
0.25
Y
30.0 ft2
1 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
5/4/2021 12:36 PM EnergyGaugeB USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
441 ftz
441 ftz
21 ft 9 ft 11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000308
1265.7 69.44 130.37 .0974 5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
Electric Strip Heat/
None
COP:1 27 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unitt
Split
Single SEER: 16 35.4 kBtu/hr 1062 cfm 0.8 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric Tankless
LAUNDRY RM 0.99 1 gal 55.1 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ftz
DUCTS
V #
---- Supply ----
Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
Attic 6 150 ft2
Attic
15 ftz Default Leakage LAUNDRY (Default) c(Default) c
1 1
5/4/2021 12:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat:
N
Ceiling Fans:
Cooling Jan
Feb
Mar
A r
X Jun
X Jul
AugX
Se
Oct
Nov
Dec
Heatin Jan HFeb
Mar
A r
JMa
Ma
Jun
Jul
Auge
Oct
N
Nov
Dec
H
Venting Jan
Feb
X Mar
Apr
May
Jun
Jul
Aug
Sep
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (W D)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
1
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8lbs/sq.ft.
ft2
ft
0.3
GREAT RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
M WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default 8 Ibs/s .ft.
ft2
ft
0.3
M HALL
5/4/2021 12:36 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6