Loading...
HomeMy WebLinkAboutEnergy Efficiency Coder \ l FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION - Florida Department of Business and Professional Regulation - Residential Performance WNW . Project Name: ELIZABETH AVENUE PROJECT Builder Name: JUL t R 7021 Street: ELIZABETH AVENUE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Permitting Department Owner: Jurisdiction: ST LUCIE COUNTY St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. W all Types(1773.3 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1577.30 ft2 b. Frame - Wood, Adjacent R=11.0 196.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1568.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1568.00 112 6. Conditioned floor area above grade (W) 1568 b. N/A R= ft2 Conditioned floor area below grade (W) 0 c. N/A R= ft2 7. Windows(233.2 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: LAUNDRY R ft2 RM 6 150 a. U-Factor: Sgl, U=1.05 233.22 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 35.4 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 3.292 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Tankless Cap: 1 gallons 9. Floor Types (1568.0 sqft.) Insulation Area EF: 0.990 a. Slab -On -Grade Edge Insulation R=0.0 1568.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits None Total Proposed Modified Loads: 51.88 Glass/Floor Area: 0.149 PASS Total Baseline Loads: 57.15 I hereby certify that the plans and specifications covered by Review of the plans and .� T S. this calculation are in compliance with the Florida Energy specifications covered by this.0', ' Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 5-4-2021 this building will be inspected for compliance with Section 553.908 * �' I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT• BUILDING OFFICIAL: DATE: DATE: a a®- - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 5/4/2021 12:36 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY GFIEGKLIST REPURT PROJECT Title: ELIZABETH AVENUE PROJE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1568 Lot # Owner Name: Total Stories: 1 Block/Subdi%ision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: ELIZABETH AVENUE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Epsting: New (From Plans) Comment: CLIMATE v Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1568 15188.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 KITCHEN 290 2697 Yes 0 1 Yes Yes Yes 2 CLST 3 16 149 No 0 1 Yes Yes Yes 3 BEDROOM 3 152 1413.6 No 0 1 1 Yes Yes Yes 4 FOYER 49 504.7 No 0 1 Yes Yes Yes 5 GREAT RM 322 3316.6 No 0 1 Yes Yes Yes 6 BATH 2 35 325.5 No 0 1 No Yes Yes 7 HALLWAY 28 260.4 No 0 1 No Yes Yes 8 LAUNDRY RM 63 585.9 No 0 1 Yes Yes Yes 9 CLST 2 18 167.4 No 0 1 No Yes Yes 10 BEDROOM 2 150 1395 No 0 1 1 Yes Yes Yes 11 M TOILET 20 186 No 0 1 No Yes Yes 12 M BATH 114 1060.2 No 0 1 Yes Yes Yes 13 M WIC 60 558 No 0 1 Yes Yes Yes 14 MASTER BEDROO 235 2420.5 No 0 1 1 Yes Yes Yes 15 M HALL 16 148.8 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation KITCHEN 37 ft 290 ftz ____ 1 0 0 2 Slab -On -Grade Edge Insulation CLST 3 2 ft 16 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulation BEDROOM 3 32 ft 152 ftz ____ 1 0 0 5/4/2021 12:36 PM I EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 4 Slab -On -Grade Edge Insulation FOYER 7 ft 49 ft2 ---- 1 0 0 5 Slab -On -Grade Edge Insulation GREAT RM 14 ft 322 ft2 --_- 1 0 0 6 Slab -On -Grade Edge Insulation BATH 2 1 ft 35 ft2 ---- 1 0 0 7Slab-On-Grade Edge Insulation HALLWAY 1 ft 28 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulation LAUNDRY RM 9 ft 63 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulation CLST 2 1 ft 18 ft2 __-_ 1 0 0 10SIab-On-Grade Edge Insulation BEDROOM 2 12 ft 150 ft2 1 0 0 11SIab-On-Grade Edge Insulation M TOILET 1 ft 20 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulation M BATH 9 ft 114 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulation M W IC 6 ft 60 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation MASTER BEDRO 35 ft 235 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulation M HALL 1 ft 16 ft2 ____ 1 0 0 ROOF v Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1699 ft2 0 ft2 Medium N 0.3 No 0.9 No 0 22.62 ATTIC V # Type Ventilation Vent Ratio (1 in) Area FIBS IRCC 1 Full attic Vented 150 1568 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) KITCHEN 30 Blown 290 ft2 0.1 Wood 2 Under Attic (Vented) CLST 3 30 Blown 16 ft2 0.1 Wood 3 Under Attic (Vented) BEDROOM 3 30 Blown 152 ft2 0.1 Wood 4 Under Attic (Vented) FOYER 30 Blown 49 ft2 0.1 Wood 5 Under Attic (Vented) GREAT RM 30 Blown 322 ft2 0.1 Wood 6 Under Attic (Vented) BATH 2 30 Blown 35 ftz 0.1 Wood 7 Under Attic (Vented) HALLWAY 30 Blown 28 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY RM 30 Blown 63 ft2 0.1 Wood 9 Under Attic (Vented) CLST 2 30 Blown 18 ft2 0.1 Wood 10 Under Attic (Vented) BEDROOM 2 30 Blown 150 ft2 0.1 Wood 11 Under Attic (Vented) M TOILET 30 Blown 20 ft2 0.1 Wood 12 Under Attic (Vented) M BATH 30 Blown 114 ft2 0.1 Wood 13 Under Attic (Vented) M WIC 30 Blown 60 ft2 0.1 Wood 14 Under Attic (Vented) MASTER BEDRO 30 Blown 235 ft2 0.1 Wood 15 Under Attic (Vented) M HALL 30 Blown 16 ft2 0.1 Wood 5/4/2021 12:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 13-11alie EtEt n Arpn1 E Exterior Concrete Block - Int Insul KITCHEN 4.1 25 0 9 4 233.3 ft2 0 0 0.3 0 2 S Exterior Concrete Block - Int Insul KITCHEN 4.1 12 0 9 4 112.0 ft2 0 0 0.3 0 3 E Exterior Concrete Block - Int Insul CLST 3 4.1 2 0 9 4 18.7 ft2 0 0 0.3 0 4 N Exterior Concrete Block - Int InsuBEDROOM 3 4.1 12 0 9 4 112.0 ft2 0 0 0.3 0 5 E Exterior Concrete Block - Int InsuBEDROOM 3 4.1 12 0 9 4 112.0 ft2 0 0 0.3 0 _ 6 W Exterior Concrete Block - Int InsuBEDROOM 3 4.1 8 0 9 4 74.7 ft2 0 0 0.3 0 7 N Exterior Concrete Block - Int Insul FOYER 4.1 7 0 10 4 72.3 ftz 0 0 0.3 0 8 S Exterior Concrete Block - Int InsuIGREAT RM 4.1 14 0 10 4 144.7 ft2 0 0 0.3 0 9 E Exterior Concrete Block - Int InsuLAUNDRY R 4.1 9 0 9 4 84.0 ft2 0 0 0.3 0 10 N Garage Frame - Wood LAUNDRY R 11 7 0 9 4 65.3 ft2 0 0.1 0.3 0 11 N Garage Frame - Wood CLST 2 11 2 0 9 4 18.7 ft2 0 0.1 0.3 0 12 W Exterior Concrete Block - Int InsuBEDROOM 2 4.1 12 0 9 4 112.0 ft2 0 0 0.3 0 13 N Garage Frame - Wood BEDROOM 2 11 12 0 9 4 112.0 ft2 0 0.1 0.3 0 14 W Exterior Concrete Block - Int Insul M BATH 4.1 9 0 9 4 84.0 ft2 0 0 0.3 0 15 W Exterior Concrete Block- Int Insul M W IC 4.1 6 0 9 4 56.0 ft2 0 0 0.3 0 16 E Exterior Concrete Block - Int InsuMASTER BE 4.1 4 0 10 4 41.3 ft2 0 0 0.3 0 17 S Exterior Concrete Block - Int InsuMASTER BE 4.1 14 0 10 4 144.7 ft2 0 0 0.3 0 18 W Exterior Concrete Block - Int InsuMASTER BE 4.1 17 0 10 4 175.7 ft2 0 0 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated LAUNDRY R None .23 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Single Yes 1.05 0.25 Y 15.0 ft2 1 ft 4 in 1 ft 4 in None None 2 S 2 Metal Low-E Single Yes 1.05 0.25 Y 15.0 ft2 1 ft 4 in 1 ft 4 in None None 3 N 4 Metal Low-E Single Yes 1.05 0.25 Y 30.0 ft2 1 ft 4 in 1 ft 4 in None None 4 N 7 Metal Low-E Single Yes 1.05 0.25 Y 48.0 ft2 9 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 5 S 8 Metal Low-E Single Yes 1.05 0.25 Y 48.0 ft2 1 ft 4 in 1 ft 4 in None None 6 W 12 Metal Low-E Single Yes 1.05 0.25 Y 20.0 ft2 1 ft 4 in 1 ft 4 in None None 7 W 14 Metal Low-E Single Yes 1.05 0.25 Y 9.0 ft2 1 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 8 E 16' Metal Low-E Single Yes 1.05 0.25 Y 18.2 ft2 5 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 9 W 18 Metal Low-E Single Yes 1.05 0.25 Y 30.0 ft2 1 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 5/4/2021 12:36 PM EnergyGaugeB USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 441 ftz 441 ftz 21 ft 9 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000308 1265.7 69.44 130.37 .0974 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitt Split Single SEER: 16 35.4 kBtu/hr 1062 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless LAUNDRY RM 0.99 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ftz DUCTS V # ---- Supply ---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 150 ft2 Attic 15 ftz Default Leakage LAUNDRY (Default) c(Default) c 1 1 5/4/2021 12:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling Jan Feb Mar A r X Jun X Jul AugX Se Oct Nov Dec Heatin Jan HFeb Mar A r JMa Ma Jun Jul Auge Oct N Nov Dec H Venting Jan Feb X Mar Apr May Jun Jul Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 1 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8lbs/sq.ft. ft2 ft 0.3 GREAT RM Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY RM Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8lbs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default 8 Ibs/s .ft. ft2 ft 0.3 M HALL 5/4/2021 12:36 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.