HomeMy WebLinkAboutEPL DISPLAY CARDFORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
3259 TURNABOUT LANE,PALM CITY,FL,34994
1. New construction or existing New (From Plans)
10.
Wall Types(2917.8 sgft.)
Insulation
Area
2. Single family or multiple family
Detached
a. Frame - Wood, Exterior
R=11.0
2917.80 ft2
3. Number of units, if multiple family
1
cb. N/A
R=
z
ft2
4. Number of Bedrooms
2
d. N/A
R=
ft2
5. Is this a worst case?
No
11.
Ceiling Types(3494.0 sqft.)
Insulation
Area
6. Conditioned floor area above grade (ft2)
3494
a. Roof Deck (Unvented)
R=21.0
2976.00 ft2
Conditioned floor area below grade (ft2)
0
b. Roof Deck (Unvented)
R=21.0
518.00 ft2
c. N/A
R=
ft2
7. Windows" Description
Area
12.
Ducts, location & insulation level
R ft2
a. U-Factor: Dbl, U=0.56
756.95 ft2
a. a. Sup: Attic, Ret: Attic, AH: Main
6 754
SHGC: SHGC=0.23
b.
b. U-Factor: N/A
ft2
C.
SHGC:
13.
Cooling Systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
36.0 SEER:16.00
SHGC:
Area Weighted Average Overhang Depth:
5.293 ft
Area Weighted Average SHGC:
0.230
14.
Heating Systems
kBtu/hr
Efficiency
8. Skylights Description
Area
a. Electric Strip Heat
36.0
COP:1.00
U-Factor:(AVG) N/A
N/A ft2
SHGC(AVG): N/A
15.
Hot Water Systems
9. Floor Types Insulation
Area 2
a. Electric
Cap:
40 gallons
a. Slab -On -Grade Edge Insulation R= 0.0
2976.00 ft
EF: 0.920
b. Raised Floor R= 36.0
518.00 ft2
b. Conservation features
c. N/A R=
ft
None
16.
Credits
CF,
CV, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Cgde\complj6nt f4ures.
Builder Signature: c'/Vy V Date: 1 "
Address of New Home: 3259 TURNABOUT LANE City/FL Zip: PALM CITY,FL,34994
'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for
energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the
Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff.
`*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/7/2022 11:00:34 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: DWYER RESIDENCE
Builder Name:
Street: 3259 TURNABOUT LANE
Permit Office: ST. LUCIE
City, State, Zip: PALM CITY, FL, 34994
Permit Number:
Owner: CHARLIE AND KIM DWYER
Jurisdiction: 6611000
Design Location: FL, VERO_BEACH_MUNICIPAL_ARPT
County: St. Lucie(Florida
Climate Zone 2)
1. New construction or existing New (From Plans)
10. Wall Types(2917.8 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Frame - Wood, Exterior
R=11.0 2917.80 ft2
3. Number of units, if multiple family 1
0, N/A
z
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types(3494.0 sgft.)
Insulation Area
6. Conditioned floor area above grade (ft2) 3494
a. Roof Deck (Unvented)
R=21.0 2976.00 ft2
Conditioned floor area below grade (ft2) 0
b. Roof Deck (Unvented)
R=21.0 518.00 ft2
c. N/A
R= ft2
7. Windows(757.0 sgft.) Description Area
12. Ducts, location & insulation level R ft2
a. U-Factor: Dbl, U=0.56 756.95 ft2
a. a. Sup: Attic, Ret: Attic, AH:
Main 6 754
SHGC: SHGC=0.23
b.
b. U-Factor: N/A ft2
C.
SHGC:
13. Cooling Systems
kBtu/hr Efficiency
c. U-Factor: N/A ft2
a. Central Unit
36.0 SEER:16.00
SHGC:
Area Weighted Average Overhang Depth: 5.293 It
Area Weighted Average SHGC: 0.230
14. Heating Systems
kBtu/hr Efficiency
8. Skylights Description Area
a. Electric Strip Heat
36.0 COP:1.00
U-Factor:(AVG) N/A N/A ft2
SHGC(AVG): N/A
9. Floor Types Insulation Area
15. Hot Water Systems
2
a. Slab -On -Grade Edge Insulation R= 0.0 2976.00 ft2
a. PropaneTankless
Cap: 1 gallons
b. Raised Floor R= 36.0 518.00 ft
b. Conservation features
EF: 0.59
c. N/A R= ft2
None
16. Credits
CF, CV, Pstat
Glass/Floor Area: 0.217 Total Proposed Modified Loads: 96.71
Total Baseline Loads: 99.73
PASS
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
04THE S74
Code.
calculation indicates compliance
A,
i r
PREPARED BY: ��,�,
with the Florida Energy Code.
Before is
F. n,nr"., •-`_ ':,.;moo
construction completed
�2
this building will be inspected for
re
a t7
DATE: i/�
compliance with Section 553.908
Florida Statutes.
a
de n is in compliance
I hereby certify that this buildi:T'
j'1'COp
with the Florida Energy Code.
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: / ^ =�6 2 Z.
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance with a proposed duct leakage On requires a PERFORMANCE Duct Leakage Test Report confirming duct
leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
1/10!'202210:28:50 AM EnergyGaugeS USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: DWYER RESIDENCE
Builder Name:
Street: 3259 TURNABOUT LANE
Permit Office: ST. LUCIE
City, State, Zip: PALM CITY, FL, 34994
Permit Number:
Owner: CHARLIE AND KIM DWYER
Jurisdiction: 6611000
Design Location: FL, VERO_BEACH_MUNICIPAL_ARPT
County: St. Lucie(Florida Climate Zone 2)
1. New construction or existing New (From Plans)
10. Wall Types(2917.8 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Frame - Wood, Exterior
R=11.0 2917.80 ftz
3. Number of units, if multiple family 1
b. N/A
z
R= ftz
4. Number of Bedrooms 2
d. N/A
R= ftz
5. Is this a worst case? No
11. Ceiling Types(3494.0 sgft.)
Insulation Area
6. Conditioned floor area above grade (ftz) 3494
a. Roof Deck (Unvented)
R=21.0 2976.00 ftz
Conditioned floor area below grade (ftz) 0
b. Roof Deck (Unvented)
R=21.0 518.00 ftz
c. N/A
R= ftz
7. Windows(757.0 sgft.) Description Area
12. Ducts, location & insulation level R ftz
a. U-Factor: Dbl, U=0.56 756.95 ftz
a. a. Sup: Attic, Ret: Attic, AH:
Main 6 754
SHGC: SHGC=0.23
b.
b. U-Factor: N/A it
C.
SHGC:
13. Cooling Systems
kBtu/hr Efficiency
c. U-Factor: N/A ftz
a. Central Unit
36.0 SEER:16.00
SHGC:
Area Weighted Average Overhang Depth: 5.293 ft
Area Weighted Average SHGC: 0.230
14. Heating Systems
kBtu/hr Efficiency
8. Skylights Description Area
a. Electric Strip Heat
36.0 COP:1.00
U-Factor.(AVG) N/A N/A ftz
SHGC(AVG): N/A
9. Floor Types Insulation Area
15. Hot Water Systems
z
a. Slab -On -Grade Edge Insulation R= 0.0 2976.00 ftz
a. PropaneTankless
Cap: 1 gallons
b. Raised Floor R= 36.0 518.00 ft
b. Conservation features
EF: 0.590
c. N/A R= ftz
None
16. Credits
CF, CV, Pstat
Glass/Floor Area: 0.217 Total Proposed Modified Loads: 96.71
Total Baseline Loads: 99.73
PASS
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
04THE STg7�
Code.
calculation indicates compliance
_IV,
i n
PREPARED BY:
with the Florida Energy Code.
y
Before construction is completed
v
this building will be inspected for
a o
DATE:?z
compliance with Section 553.908;$
Florida Statutes.
a
r'%'C0
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance with a proposed duct leakage On requires a PERFORMANCE Duct Leakage Test Report confirming duct
leakage to outdoors, tested in accordance with ANSI/RESNETACC 380, is not greater than 0.030 On for whole house.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
1A 0/2022 10:28:50 AM EnergyGauge@ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
(Total Exposed Area = 3494 sq.ft.)
#
Ceiling Type
Space
R-Value Ins, Type
Area U-Factor Framing Frac.
Truss Type
_ 1 Under Attic(Unvented)
2nd Floor
21.0 Blown
518.Oft2 0.024
0.11
Wood
2 Under Attic(Unvented)
Main
0.0 Blown
2976.Oft2 0.042
0.11
Wood
WALLS
(Total Exposed Area = 2918 sq.ft.)
Adjacent
Cavity Width
Height Area U-
Sheath Frm.
Solar Below
V# Ornt
To
Wall Type
Space
R-Value Ft
In
Ft In sq.ft. Factor
R-Value Frac.
Absor. Grade
-1 W
Exterior
Frame - Wood
Main
11.0 15.0
6
8.0 0 124.0 0.091
0.15 0.23
0.50 0 %
2 N
Exterior
Frame - Wood
Main
11.0 26.0
0
8.0 0 208.0 0.091
0.15 0.23
0.50 0 %
-3 W
Exterior
Frame - Wood
Main
11.0 19.0
0
8.0 0 152.0 0.091
0.15 0.23
0.50 0 %
-4 N
Exterior
Frame - Wood
Main
11.0 22.0
7
17.0 8 399.0 0.091
0.15 0.23
0.50 0 %
-5 E
Exterior
Frame - Wood
Main
11.0 6.0
0
17.0 8 106.0 0.091
0.15 0.23
0.50 0 %
-6 N
Exterior
Frame - Wood
Main
11.0 5,0
4
17.0 8 94.2 0.091
0.15 0.23
0.50 0 °%
7 N
Exterior
Frame - Wood
Main
11.0 16.0
1
17.0 8 284.1 0.091
0.15 0.23
0.50 0 %
-8 E
Exterior
Frame - Wood
Main
11.0 17.0
6
17.0 6 309.2 0.091
0.15 0.23
0.50 0 %
9 S
Exterior
Frame - Wood
Main
11.0 16.0
0
8.0 0 128.0 0,091
0.15 0.23
0.50 0 %
10 S
Exterior
Frame - Wood
Main
11.0 2.0
1
8.0 0 16.7 0.091
0.15 0.23
0.50 0 %
_ 11 E
Exterior
Frame - Wood
Main
11.0 5.0
4
8.0 0 42.7 0.091
0.15 0.23
0.50 0 %
12 S
Exterior
Frame - Wood
Main
11.0 12.0
2
8.0 0 97.3 0.091
0.15 0.23
0.50 0 %
_ 13 W
Exterior
Frame - Wood
Main
11.0 5.0
4
8.0 0 42.7 0.091
0.15 0.23
0.50 0 %
_ 14 S
Exterior
Frame - Wood
Main
11.0 45.0
3
8.0 0 362.0 0.091
0.15 0.23
0.50 0 %
_ 15 W
Exterior
Frame - Wood
Main
11.0 3.0
4
8.0 0 26.7 0.091
0.15 0.23
0.50 0 %
_ 16 S
Exterior
Frame - Wood
Main
11.0 7.0
1
8.0 0 56.7 0.091
0,15 0.23
0.50 0 %
_ 17 E
Exterior
Frame - Wood
Main
11.0 10.0
2
8.0 0 81.3 0.091
0.15 0.23
0.50 0 %
_ 18 S
Exterior
Frame - Wood
Main
11.0 3.0
0
8.0 0 24.0 0.091
0.15 0.23
0.50 0 %
_ 19 E
Exterior
Frame - Wood
2nd Floor
11.0 20.0
3
8.0 0 162.0 0.099
0.15 0.23
0.50 0 %
20 S
Exterior
Frame - Wood
2nd Floor
11.0 25.0
2
8.0 0 201.3 0.099
0.15 0.23
0.50 0 %
DOORS
(Total Exposed Area = 46 sq.ft.)
Width
Height
# Ornt
Adjacent To Door Type
Space
Storms
U-Value Ft In
Ft In
Area
1 N
Exterior Insulated
Main
Metal
0.46 5.00 9
8.00 0
46.Oft2
WINDOWS
(Total Exposed Area = 757 sq.ft.)
Wall
----- Overhang -----
✓# Ornt
ID
Frame
Panes NFRC
. U-Factor SHGC
Imp Storm
Area
Depth Separation
Interior Shade
Screening
_ 1 W
1
Metal
Double (Tinted)
Yes
0.56 0.23
Y Y
12.0112
1.0 ft 0 in 1.0 ft 10 in
Drapes/blinds
None
-2 W
1
Metal
Double (Tinted)
Yes
0.56 0.23
Y Y
14.02
1.0 ft 0 in 1.0 ft 7 in
Drapes/blinds
None
3 W
3
Metal
Double (Tinted)
Yes
0.56 0.23
N Y
8.0ft2
1.0 It 0 in 0.0 ft 7 in
Drapes/blinds
None
-4 W
3
Metal
Double (Tinted)
Yes
0.56 0.23
Y Y
15.8ft2
1.0 fl 0 in 2.0 ft 7 in
Drapes/blinds
None
5 N
4
Metal
Double (Tinted)
Yes
0.56 0.23
Y Y
48.0112
1.0 ft 0 in 12.0 ft 2 in
Drapes/blinds
None
6 N
7
Metal
Double (Tinted)
Yes
0.56 0.23
Y Y
23.2112
1.0 ft 0 in 0.0 ft 2 in
Drapes/blinds
None
7 N
7
Metal
Double (Tinted)
Yes
0.56 0.23
Y Y
135.81`12
1.0 ft 0 in 0.0 ft 2 in
Drapes/blinds
None
8 E
8
Metal
Double (Tinted)
Yes
0.56 0-23
Y Y
21.91112
1.0 ft 0 in 3.0 ft 0 in
Drapes/blinds
None
9 E
8
Metal
Double (Tinted)
Yes
0.56 0.23
Y Y
10.01112
1.0 ft 0 in 3.0 ft 5 in
Drapes/blinds
None
10S
9
Metal
Double (Tinted)
Yes
0.56 0.23
Y Y
60.0f12
14.0 ft 6 in 0.0 ft 6 in
Drapes/blinds
None
11 E
11
Metal
Double (Tinted)
Yes
0.56 0.23
Y Y
14.7112
15.0 ft 2 in 0.0 ft 6 in
Drapes/blinds
None
12S
12
Metal
Double (Tinted)
Yes
0.56 0.23
Y Y
40.0ft2
6.0 ft 2 in 0.0 If 6 in
Drapes/blinds
None
13S
14
Metal
Double (Tinted)
Yes
0.56 0.23
Y Y
72.0ft2
11.0 ft 6 in 0.0 ft 6 in
Drapesiblinds
None
14S
16
Metal
Double (Tinted)
Yes
0.56 0.23
Y Y
30.0ft2
1.0 ft 0 in 0.0 ft 4 in
Drapes/blinds
None
15E
17
Metal
Double (Tinted)
Yes
0.56 0.23
Y Y
35.0112
1.0 It 0 in 2.0 ft 3 in
Drapes/blinds
None
16N
4
Metal
Double (Tinted)
Yes
0.56 0.23
Y Y
12.0112
1.0 It 0 in 5.0 ft 5 in
Drapes/blinds
None
17S
14
Metal
Double (Tinted)
Yes
0.56 0.23
Y Y
13.3ft2
11.0 ft 6 in 0.0 ft 6 in
Drapesiblinds
None
18S
14
Metal
Double (Tinted)
Yes
0.56 0.23
Y Y
80.5ft2
11.0 ft 6 in 0.0 ft 4 in
Drapes/blinds
None
1Ill 0./2022 10:28:50 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: DWYER RESIDENCE
Address type:
Street Address
Building Type: User
Bedrooms: 2
Lot #:
---
Owner: CHARLIE AND KIM DWYER
Conditioned Area: 3494
Block/SubDivision:
---
Total Stories: 2
PlatBook:
---
Builder Name:
Worst Case: No
Street:
3259 TURNABOUT LANE
Permit Office: ST. LUCIE
Rotate Angle: 0
County:
St. Lucie
Jurisdiction: 6611000
Cross Ventilation: Yes
City, State, Zip:
PALM CITY,
Family Type: Detached
Whole House Fan: No
FL. 34994
New/Existing: New (From Plans)
Terrain: Suburban
Year Construct: 2021
Shielding: Suburban
Comment:
CLIMATE
Design
Design Temp
Int Design Temp
Heating Design Daily temp
Location
Tmy Site
97.5% 2.5%
Winter Summer
Degree Days Moisture Range
FL, VERO_BEACH_MUNICIP
FL_VERO_BEACH_MUNICIPA 45 90
70 75
299 64 Medium
BLOCKS
Number Name
Area
Volume
1 Blockl
3494
27952
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms
Finished Cooled Heated
1 Main
2976
23808 Yes 2
2
Yes Yes Yes
2 2nd Floor
518
4144 No 2
0
Yes Yes Yes
FLOORS
(Total Exposed Area = 3494 sq.ft.)
# Floor Type
Space
Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet
1 Slab -On -Grade Edge Ins
Main
90 0
2976 ft 0.360
--- 0.00 0.25 0.75
2 Raised Floor
2nd Floor
--- ---
518 ft 0.034
36 0.00 0.50 0.50
ROOF
Roof Gable Roof
Rad Solar
SA Emitt Emitt Deck Pitch
# Type
Materials
Area Area Color
Barr Absor.
Tested Tested Insul. (deg)
1 Hip
Composition shingles
3907 ftz UBlft9shed, Galvaniz6d 0.85
No 0.7 No 21 26.57
ATTIC
# Type
Ventilation
Vent Ratio (1 in)
Area FIBS
IRCC
_ 1 Partial cathedral ceiling
Unvented
0 3494 ft2 N
N
1;10/202210:28:50 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS(Continued)
19E 19 Metal Double (Tinted)
20S 20 Metal Double (Tinted)
21 S 20 Metal Double (Tinted)
Yes 0.56 0.23 Y Y 15.8ft2 1.0 ft 0 in 0.0 ft 7 in Drapes/blinds None
Yes 0.56 0.23 Y Y 80.0ft2 4.0 ft 0 in 3.0 ft 1 in Drapes/blinds None
Yes 0.56 0.23 Y Y 14.7ft2 4.0 ft 0 in 6.0 ft 9 in Drapes/blinds None
INFILTRATION
# Scope Method
SLA CFM50 ELA EgLA ACH ACH50 Space(s)
1 Wholehouse Proposed ACH(50)
0.00036 3261 178.91 335.89 0.1810 7.0 All
MASS
# Mass Type
Area Thickness Furniture Fraction Space
1 Default(8 Ibs/sq.ft.)
2 Default(8 Ibs/sq.ft.)
0 ftz 0 ft 0.30 Main
0 ft- 0 ft 0.30 2nd Floor
HEATING SYSTEM
# System Type
Subtype AHRI # Efficiency Capacity ----Geothermal HeatPump---- Ducts Block
kBtu/hr Entry Power Volt Current
1 Electric Strip Heat
None 201336693 COP: 1.00 36.0 0.00 0.00 0.00 sys#1 1
COOLING SYSTEM
# System Type Subtype/Speed AHRI # Efficiency Capacity Air Flow SHR Duct Block
kBtu/hr cfm
1 Central Unit
None!Single 201336693 SEER:16.0 36.0 1080 0.75 sys#1 1
HOT WATER SYSTEM
System Type Subtype
Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length
1 Propane Tankless
Main 0.59 (0.59) 1.00 gal 70 gal 120 deg Standard =>R-3 85
Recirculation Recirc Control
System Type
Loop Branch Pump DWHR Facilities Equal DWHR Other Credits
length length power Connected Flow Eff
1 No
NA NA NA No NA NA NA None
DUCTS
VDuct ----Supply----- ----Return----- Air CFM 25 CFM 25 HVAC #
# Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT ON RLF Heat Cool
1 Attic 6.0 754 ftz Attic
6.0 716 ftz Prop. Leak Free Main -- --- 0.03 0.50 1 1
MECHANICAL VENTILATION
Type Supply CFM Exhaust CFM HRV Fan Run Time Heating System Cooling System
Runtime Vent 4.0
0.0 0.0 0.0 W 0 % 1 - Electric Strip Heat 1 - Central Unit
11%2022 10:28:50 AM EnergyGaugeS USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans: N
Cooling [ ] Jan
[] Feb
[ ] Mar
[ ] Apr
[ ] May
[X] Jun
[X] Jul
[X] Aug
[X] Sep
[ ] Oct
[ ] Nov
[I Dec
Heating [X] Jan
[XI Feb
[X] Mar
[I Apr
[ ] May
[ J Jun
[ ] Jul
[ ] Aug
[ J Sep
[ ] Oct
[X] Nov
[XJ Dec
Venting [ ] Jan
[ ] Feb
[X] Mar
[X] Apr
[ ] May
[ ] Jun
[ ] Jul
[ J Aug
[ ] Sep
[X] Oct
[X] Nov
[ ]Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3 4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78 78
78 78
78
78
78
78
78
78
78
78
80
78
80
78
80
78
BO
78
Cooling (WEH)
AM
PM
78
78
78
78
78 78
78 78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66 66
68 68
66
68
68
68
68
68
68
68
68
68
6B
68
68
66
68
66
Heating (WEH)
AM
PM
66
68
66
68
66 66
68 68
66
68
68
68
68
68
68
68
68
68
68
68
68
66
68
66
1111 W2022 1028:50 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5