Loading...
HomeMy WebLinkAboutFLOOR PLANDEMOLITION FLOOR PLAN 14"=1'-0"W.I. CLOS.CLOS.OFFICEMASTER BATHMASTERBEDROOMEXISTUTILITYEXISTBEDROOM.KITCHENWET BARFAMILY ROOMNEW ENTRYEXISTPUMP HOUSE14" x 3" LONG TAPCONSINTO EXIST SLAB@ 12" O.C.SLAB DETAIL 34"=1'-0"6 MILL VISQUEENVAPOR BARRIERCOMPACTED & TERMITETREATED 2500 PSF FILL4" MIN 2500 PSI FIBERMESHCONCREPAIRS 24" OR LESS8" LONG #5 BARDOWELLED & EPOXIED INTO EXIST SLAB@ 12" O.C.SLAB DETAIL 34"=1'-0"6 MILL VISQUEENVAPOR BARRIERCOMPACTED & TERMITETREATED 2500 PSF FILLREPAIRS 24" OR GREATERA-1 DATE OF SHEET REVISIONS STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. 34996 1-7-22 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987MR. AND MRS. DWYER A RENOVATION FOR PALM CITY FLORIDA 3259 TURNABOUT LANE DESIGNATE EXISTAREA TO BE FRAMED INNEW 2x4 WOOD STUDSEXIST. 2x4 WOOD STUDSTO REMAINW.I. CLOS.ABKEYNOTESCLOS.OFFICEMASTER BATHBMASTERBEDROOMNEWUTILITYEXISTBEDROOMABKITCHENWET BARFAMILY ROOMNEW ENTRYPUMP HOUSEFLOOR PLAN 14"=1'-0"POOLBATHOUTDOOR KITCHEN3259 TURNABOUT LANEFL-13192.4JAMES HARDIFLORIDAN.A.ROOFFLORIDA BUILDING CODE 2017 RESIDENTIAL, LOCAL CODES AND GOVERNINGDONT USE 33% STRESS INCREASES FOR ROOF TRUSSES WIND LOAD 170 MPH AS PER ASCE 7-10ASCE 7-16N.D.S. 2001A.I.S.C. NINTH EDITIONACI 421.1-R92ACI 318-02REGULATONS.CODESDEAD LOAD: 25 PSFLIVE LOAD: 30 PSFACCORDANCE WITH THE 7 TH EDITION 2020 FLORIDA BUILDING CODE 2020THE FOLLOWING SUPERIMPOSED LOADING HAVE BEEN UTILIZED.WIND DIRECTIONALITY FACTOR Kd = .85EXPOSURE " C "RISK CATT.IINEC 2017A-2 DATE OF SHEET REVISIONS STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. 34996 1-7-22 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987MR. AND MRS. DWYER A RENOVATION FOR PALM CITY FLORIDA 3259 TURNABOUT LANE ABLOFT KEYNOTESALOFTSTAIRSLOFT FLOOR PLAN 14"=1'-0"BCCA-3 DATE OF SHEET REVISIONS STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. 34996 1-7-22 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987MR. AND MRS. DWYER A RENOVATION FOR PALM CITY FLORIDA 3259 TURNABOUT LANE SECTION " A " 12"=1'-0"DATE OF SHEET REVISIONS STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. 34996 1-7-22 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987MR. AND MRS. DWYER A RENOVATION FOR PALM CITY FLORIDA 3259 TURNABOUT LANEA-4 SECTION " B " 12"=1'-0"SECTION " C " 12"=1'-0"STAIR SECTION 12"=1'-0"DETAIL # 1 1-12" =1'-0"DETAIL # 2 1-12" =1'-0"AA-5AA-5BA-5DATE OF SHEET REVISIONS STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. 34996 1-7-22 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987MR. AND MRS. DWYER A RENOVATION FOR PALM CITY FLORIDA 3259 TURNABOUT LANEA-5 FRONT ELEVATION 14"=1'-0"REAR ELEVATION 14"=1'-0"SECTION " D " 12"=1'-0"DATE OF SHEET REVISIONS STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. 34996 1-7-22 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987MR. AND MRS. DWYER A RENOVATION FOR PALM CITY FLORIDA 3259 TURNABOUT LANEA-6 RIGHT SIDE ELEVATION 14"=1'-0"LEFT SIDE ELEVATION 14"=1'-0"DATE OF SHEET REVISIONS STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. 34996 1-7-22 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987MR. AND MRS. DWYER A RENOVATION FOR PALM CITY FLORIDA 3259 TURNABOUT LANEA-7 REMARKSSIZEDOOR SCHEDULETHK.TYPE & MAT.HWMARKMFG.DESCRIPTIONUNIT SIZEMARK W H RADIUSMANUF.REMARKSWINDOW SCHEDULEAS DESCRIBED IN PRODUCT CONTROL APPROVALSALL WINDOWS SHALL BE INSTALLEDA-8 DATE OF SHEET REVISIONS STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. 34996 1-7-22 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987MR. AND MRS. DWYER A RENOVATION FOR PALM CITY FLORIDA 3259 TURNABOUT LANE 14" TAPCON SEE CHARTFOR SPACING14" TAPCON SEE CHARTFOR SPACING2-2 x 12 WOOD HDRFIN FLOORDOOR HEADER DETAIL 3/4"=1'-0"2-SIMPSON LSTA 12 STRAIGHT STRAPW/ 10 - 10 d NAILS2-2 x 12 WOOD HDR2 x 4 NAILER2- JACK STUD190151901719002A1900719007190311903119011 19015718609718609 1901719015718609718609 19017BV28BV28DH79SDH77SDH74SBV28BV28DH76SVPI-431DH1101SSPH-4 SIMPSON ANCHOR W/ 10-10d x 112" INTO STUDSR703.2Water-resistive barrier.One layer of HENRY FORTIFLASH BUTYL FLASHING MEMBRANEWINDOW FRAMING DETAIL 12"=1'-0"A-9 DATE OF SHEET REVISIONS STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. 34996 1-7-22 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987MR. AND MRS. DWYER A RENOVATION FOR PALM CITY FLORIDA 3259 TURNABOUT LANE DESIGNATE EXISTAREA TO BE FRAMED INSD & CMDSD & CMDSD & CMDEEEW.I. CLOS.CLOS.OFFICEMASTER BATHMASTERBEDROOMEXISTCLOS.NEWUTILITYEXISTBRDROOMKITCHENWET BARFAMILY ROOMNEW ENTRYPOOLBATH MECHANICAL FIRST FLOOR PLAN 1/4"=1'-0"EEEESD & CMDAC-1 DATE OF SHEET REVISIONS STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. 34996 1-7-22 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987MR. AND MRS. DWYER A RENOVATION FOR PALM CITY FLORIDA 3259 TURNABOUT LANE SD & CMD LOFT MECHANICAL PLAN 14"=1'-0"EAC-2 DATE OF SHEET REVISIONS STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. 34996 1-7-22 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987MR. AND MRS. DWYER A RENOVATION FOR PALM CITY FLORIDA 3259 TURNABOUT LANE DESIGNATE EXISTAREA TO BE FRAMED INSD & CMDSD & CMDSD & CMDE ELECTRICAL PLAN 316"=1'-0"EEW.I. CLOS.CLOS.OFFICEMASTER BATHMASTERBEDROOMNEWUTILITYEXISTCLOS.KITCHENWET BARFAMILY ROOMNEW ENTRYEXISTPUMP HOUSEPOOLBATHEEGENERAL NOTEALL EXIST LIGHT FIXTURES AND RECEPTACLES ARE TO BEREMOVED AND NEW ADDEDJUNCTION BOXJWALL SWITCHGFIWPGFIWEATHERPROOF GROUND FAULT INTERRUPTER OUTLETHALF SWITCHED RECEPTACLE OUTLETQUADRAPLEX RECEPTACLE OUTLETGROUND-FAULT INTERRUPTER OUTLETDUPLEX RECEPTACLE OUTLETDEDICATED RECEPTACLE OUTLETSPECIAL RECEPTACLE OUTLET 240VEXHAUST FANVPFLOOD LIGHTCEILING RECESSED LIGHT FIXTURE - VAPOR PROOFCEILING RECESSED LIGHT FIXTURE - DIRECTIONALFLUORESCENT LIGHTING FIXTURE - SURFACE MTD.CEILING MOUNTED LIGHTING FIXTUREWALL MOUNTED LIGHTING FIXTURETELEPHONE JACKELECTRICAL PANELPADDLE FANSMOKE DETECTORTELEVISION JACKPUSHBUTTON SWITCHFUSE OR DISCONNECT SWITCHCEILING RECESSED LIGHTING FIXTUREDUPLEX FLOOR RECEPTACLESDTVECHIMECNEW RECEPTACLENCCABLEDUPLEX RECEPTACLE OUTLET LIVE TO A SWITCHPENDANT LIGHTSROUND CEILING RECESSED LIGHTING FIXTUREE-1 DATE OF SHEET REVISIONS STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. 34996 1-7-22 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987MR. AND MRS. DWYER A RENOVATION FOR PALM CITY FLORIDA 3259 TURNABOUT LANE SD & CMD LOFT ELECTRICAL PLAN 14"=1'-0"EE-2 DATE OF SHEET REVISIONS STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. 34996 1-7-22 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987MR. AND MRS. DWYER A RENOVATION FOR PALM CITY FLORIDA 3259 TURNABOUT LANE ELECTRICAL NOTES* HOUSE PANEL***PROVIDE "AFCI" BREAKERSAT ALL BEDROOM OUTLETS TO COMPLY WITHNEC. 210.12 ( B )**SMOKE DETECTOR SHALL BE 120 V. WITH BATTERYBACK-UP & ALL SMOKE DETECTORS MUST BEINTERCONNECTED.SWITCHSMOKE DETECTOR CONNECTION DETAIL ntsNONMETALICPROTECTIVESLEEVEBOLTED-TYPE CONNECTION DEVICE OREXOTHERMIC WELDDIRECT CONTACT WITHEARTHNo. 4 AWG OR LARGER BARE COPPER CONDUCTOROR STEEL REINFORCING BAR OR ROD NOT LESSTHAN 1/2- INCH DIAMETERENCASED GROUNDING ELECTRODE DETAILSWITCHLEGKITCHEN ORBATHROOM LIGHTSMOKE DETECTOR2 in.MIN.20 FTMIN.NOTE:NON METALIC - SHEATHEDCABLE(ROMEX CABLE) SHALLCOMPLYWITH NFPA-10 ARTICLE 336PARTICULARLY PARAGRAPH336-10-7 AND ALSO WITHCHAPTERS 250 300 AND 310.CONCRETEFOUNDATIONGROUNDINGELECTRODEGROUNDINGELECTRODECONDUCTORLINE SIDE OFSWITCHPHASE CONDUCTOR120 V.SDCONNECT TO A CONCRETE-ENCASED ELECTRODECONSISTING OF AT LEAST 20 FT OF ONE OR MOREBARE OR ZINC GALVANIZED STEEL REINFORCINGBARS OF NOT LESS THAN 1/2 INCH OR CONSISTINGOF AT LEAST 20 FT OF BARE COPPER CONDUCTORNOT SMALLER THAN No. 4AND LOCATED WITHINAND NEAR THE BOTTOM OF A CONCRETEFOUNDATION OR FOOTING THAT IS IN DIRECTCONTACT WITH EARTH.RISER DIAGRAMNTS* PUMP HOUSEE-3 DATE OF SHEET REVISIONS STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. 34996 1-7-22 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987MR. AND MRS. DWYER A RENOVATION FOR PALM CITY FLORIDA 3259 TURNABOUT LANE PLUMBING PLAN 316"=1'-0"DESIGNATE EXISTAREA TO BE FRAMED IN4" MIN 2500 PSI FIBERMESHCONC8" LONG #5 BARDOWELLED & EPOXIED INTO EXIST SLAB@ 12" O.C.SLAB DETAIL 34"=1'-0"6 MILL VISQUEENVAPOR BARRIER14" x 3" LONG TAPCONSINTO EXIST SLAB@ 12" O.C.SLAB DETAIL 34"=1'-0"6 MILL VISQUEENVAPOR BARRIERCOMPACTED & TERMITETREATED 2500 PSF FILL4" MIN 2500 PSI FIBERMESHCONCCOMPACTED & TERMITETREATED 2500 PSF FILLREPAIRS 24" OR GREATERREPAIRS 24" OR LESSP-1 DATE OF SHEET REVISIONS STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. 34996 1-7-22 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987MR. AND MRS. DWYER A RENOVATION FOR PALM CITY FLORIDA 3259 TURNABOUT LANE P-2 DATE OF SHEET REVISIONS STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. 34996 1-7-22 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987MR. AND MRS. DWYER A RENOVATION FOR PALM CITY FLORIDA 3259 TURNABOUT LANE PLUMBING NOTES- PROVIDE SHUT-OFF VALVE FOR EACH FIXTURE.- MATERIALS SHALL BE AS FOLLOWS: COPPER BELOW GROUND AND TYPE "M" COPPER ABOVE GROUND. 4) STORM LINES INSIDE BUILDING SHALL BE PVC SCHEDULE 40. 1) COLD WATER PIPING DOWNSTREAM OF WATER METER SHALL BE TYPE "L" 2) COLD WATER PIPES INSIDE OF SLAB SHALL BE TYPE "K" SOFT COPPER 3) SANITARY WASTE AND VENT 4" DIA. AND SMALLER SHALL BE PVC INSTALLED INSIDE POLYETHYLENE CONDUIT. NO JOINTS PERMITTED INSIDE SLAB. BUILDING SHALL BE PVC SCHEDULE 40. 5) IN COASTAL AREAS ALL SANITARY AND STORM PIPING OUTSIDE OF 6) CONDENSATE DRAIN PIPE SHALL BE PVC SCHEDULE 40 PIPE AND FITTINGS. 7) WATER HEATER RELIEF AND DRAIN LINE SHALL BE TYPE "L" COPPERSTORM LINES OUTSIDE BUILDING SHALL BE PVC SCHEDULE 80. MASTER BATHPLUMBING RISERDIAGRAMN.T.S.PLUMBING RISERDIAGRAMN.T.S.UTILITYPOOL BATHMASTER BATHKITCHENWET BARLOFTWATER NOTENEW WATER PIPING TO BE UPONOR BRAND WITH HOTWATER RECIRCULATING SYSTEMP-3 DATE OF SHEET REVISIONS STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. 34996 1-7-22 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987MR. AND MRS. DWYER A RENOVATION FOR PALM CITY FLORIDA 3259 TURNABOUT LANE