Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department Building & Code Regulations Division ` 2300 Virginia Avenue, Fort Pierce, FL 34982 — 772 462-1577 Certification for Design Load Compliance 7th Edition Project Name: Treasure Coast Homes Pro)ectAddress: 6504 Bayard Rd. Fort. Pierce, Saint Lucie County FL. 34952 Permit #: Occupancy Type: R3 Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • If submitting hard copy, submit (2) copies with all pertinent information. St Lucie Fire District requires a digitally signed electronic version. • If submitting electronically, form should be uploaded into Bluebeam. Separate submission to Fire is still required • All digital files must be in an unlocked Portable Document Format (PDF) version * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the plan reviewer. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2020 Code 7th Edition using ASCE 7-16 2. Structure Designed as (check one): x Enclosed Partially Enclosed Open 3. Risk Category: I 11 X III IV Exposure Category: B� D 4. Design Wind Velocity 170 mph 132 ASD LRFD End Zone Width: 4 ft S. Mean Roof Height 14 ft Roof Pitch: 5 :12 Parapet: NA ft 6. Components & Clad ing Design Pressures Used: 17 Zone 44g,f'r one 5: �3� b +*01( Garage: -1- 44.3 8,, 6a. Roofs r� Maximum +/- pressures: + �psf-.-/A2% 'sf Or define individual zones on the plans 7. Design Loads: Floor: 40 PSF Roof -Dead: 30 PSF Roof -Live: 25 Balcony+/- NA PSF Dock: NA PSF Deck: NA PSF Stairs: NA PSF Fence: NA PSF Railings: NA PSF 8. Were Shear Walls Considered For Structure? Yes X Not Applicable Please Explain: 9. Is a Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes No Assumed DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the current Florida Building Code as adopted. �0� 9J �2 (3tKi9�-2 ��� �l__�l L I Signatu e, Date ndSeal Print Name Cert # & Co. Cert ofAuthorization Revised 3/25/2021 Company Name &Address PM_P-7'1 6,5 1 rud IL 33�-I r