Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Calculation Form & Manual J's
RECEIVED JAN 0 0 Z018 FORM R405-2014 ST. Lucie County, Pormitting FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HERNANDEZ RESIDENCE-MULLER RD Builder Name: JDL BUILDERS Street: 10105 MULLER ROAD Permit Office: ST LUCIE COUNTY City,State,Zip: FORT PIERCE,FL, Permit Number: Owner: DAN AND HEATHER HERNANDEZ Jurisdiction: Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2540.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=5.0 2540.00 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Ic-this a worst case? 10.Ceiling Types (2569.0 sqft.) Insulation Area No a.Roof Deck(Unvented) R=20.0 2569.00 ft2 6. Conditioned floor area above grade(ft2) 2569 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(606.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:AHU 6 175 a. U-Factor: Sgl,U=0.30 284.00 ft2 SHGC: SHGC=0.21 b. U-Factor: Sgl,U=0.30 188.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.19 a.Central Unit 42.0 SEER:16.00 c. U-Factor: Sgl,U=1.11 128.00 ft2 SHGC: SHGC=0.54 13.Heating systems kBtu/hr Efficiency d. U-Factor: other(see details) 6.00 ft2 a.Electric Strip Heat 27.0 COP:1.00 SHGC: other(see details) Area Weighted Average Overhang Depth: 4.140 ft. Area Weighted Average SHGC: 0.274 14.Hot water systems 8. Floor Types (2569.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2569.00 ft2 b. Conservation features EF:0.980 b.N/A R= ft2 None c.N/A R= ft2 15.Credits None Glass/Floor Area: 0.236 Total Proposed Modified Loads: 80.80 PASS Total Baseline Loads: 87.69 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. rrr��,� ': %'.,'':• „ O� PRE E Y: Before construction is completed DATE: - - this building will be inspected for tl C compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida En y ode. �''OD W"t OWNER/AGENT. BUILDING OFFICIAL: r DATE: DATE: - Compliance re i s certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory- aled in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1,2017 ALL PROJECTS require an envelope leakage test report with envelope leakage no greater than 7 ACH50(R402.4.1.2). FRlk%e COPY 1/9/2018 8:58 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 PROJECT Title: HERNANDEZ RESIDENCE- Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2569 Lot# Owner Name: DAN AND HEATHER HERNA Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: JDL BUILDERS Rotate Angle: 0 Street: 10105 MULLER ROAD Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: Whole House Fan: No City,State,Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2569 26215 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 275 2750 No 0 1 1 Yes Yes Yes 2 M TOILET 40 400 No 0 1 Yes Yes Yes 3 M WIC 70 700 No 0 1 No Yes Yes 4 M BATH 130 1300 No 0 1 Yes Yes Yes 5 BEDROOM 2 144 1440 No 0 1 1 Yes Yes Yes 6 WIC 2 25 250 No 0 1 No Yes Yes 7 BATH 2 72 720 No 0 1 Yes Yes Yes 8 BEDROOM 3 156 1560 No 0 1 1 Yes Yes Yes 9 WIC 3 48 480 No 0 1 Yes Yes Yes 10 PLAY ROOM 143 1430 No 0 1 Yes Yes Yes 11 FAMILY ROOM 525 5775 No 0 1 Yes Yes Yes 412 ENTRY 104 1040 No 0 1 Yes Yes Yes 13 AHU 12 120 No 0 1 No Yes Yes 14 ENTRYWIC 24 240 No 0 1 No Yes Yes 15 CLST 16 160 No 0 1 Yes Yes Yes 16 STUDY 156 1560 No 0 1 Yes Yes Yes 17 UTILITY 135 1350 No 0 1 Yes Yes Yes 18 POWDER 24 240 No 0 1 Yes Yes Yes 19 HALL 76 760 No 0 1 Yes Yes Yes 20 KITCHEN 225 2250 Yes 0 1 Yes Yes Yes 21 DINING 169 1690 No 0 1 Yes Yes Yes 1/9/2018 8:58 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 L FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulation MASTER BEDRO 47 ft 0 275 ft2 ____ 1 0 0 2 Slab-On-Grade Edge Insulation M TOILET 4 ft 0 40 ft2 ____ 1 0 0 3 Slab-On-Grade Edge Insulation M W IC 1 ft 0 70 ft2 ___- 1 0 0 4 Slab-On-Grade Edge Insulation M BATH 13 ft 0 130 ft2 ____ 1 0 0 5 Slab-On-Grade Edge Insulation BEDROOM 2 12 ft 0 144 ft2 ____ 1 0 0 6 Slab-On-Grade Edge Insulation WIC 2 1 ft 0 25 ft2 ___- 1 0 0 7 Slab-On-Grade Edge Insulation BATH 2 6 ft 0 72 ft2 ____ 1 0 0 8 Slab-On-Grade Edge Insulation BEDROOM 3 25 ft 0 156 ft2 _ 1 0 0 9 Slab-On-Grade Edge Insulation WIC 3 14 ft 0 48 ft2 _--_ 1 0 0 10SIab-On-Grade Edge Insulation PLAY ROOM 5 ft 0 143 ft2 ____ 1 0 0 11Slab-On-Grade Edge Insulation FAMILY ROOM 20 ft 0 525 ft2 --_- 1 0 0 12SIab-On-Grade Edge Insulation ENTRY 8 ft 0 104 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation AHU 1 ft 0 12 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation ENTRY W IC 1 ft 0 24 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulation CLST 4 ft 0 16 ft2 -___ 1 0 0 16SIab-On-Grade Edge Insulation STUDY 12 ft 0 156 ft2 ___- 1 0 0 i 17SIab-On-Grade Edge Insulation UTILITY 22 ft 0 135 ft2 -_-_ 1 0 0 18SIab-On-Grade Edge Insulation POWDER loft 0 24 ft2 1 0 0 19SIab-On-Grade Edge Insulation HALL 4 ft 0 76 ft2 1 0 0 20SIab-On-Grade Edge Insulation KITCHEN 15 ft 0 225 ft2 1 0 0 T 21SIab-On-Grade Edge Insulation DINING 31 ft 0 169 ft2 -___ 1 0 0 i ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch u # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2873 ft2 0 ft2 Light 0.6 No 0.9 No 20 26.6 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 2569 ft2 N N 1/9/2018 8:58 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) MASTER BEDRO 20 Blown 275 ft2 0.1 Wood 2 Under Attic(Unvented) M TOILET 20 Blown 40 ft2 0.1 Wood 3 Under Attic(Unvented) MWIC 20 Blown 70ft2 0.1 Wood 4 Under Attic(Unvented) M BATH 20 Blown 130 ft2 0.1 Wood 5 Under Attic(Unvented) BEDROOM 2 20 Blown 144 ft2 0.1 Wood 6 Under Attic(Unvented) WIC 2 20 Blown 25 ft2 0.1 Wood 7 Under Attic(Unvented) BATH 2 20 Blown 72 ft2 0.1 Wood 8 Under Attic(Unvented) BEDROOM 3 20 Blown 156 ft2 0.1 Wood 9 Under Attic(Unvented) WIC 3 20 Blown 48 ft2 0.1 Wood 10 Under Attic(Unvented) PLAY ROOM 20 Blown 143 ft2 0.1 Wood 11 Under Attic(Unvented) FAMILY ROOM 20 Blown 525 ft2 0.1 Wood 12 Under Attic(Unvented) ENTRY 20 Blown 104ft2 0.1 Wood 13 Under Attic(Unvented) AHU 20 Blown 12 ft2 0.1 Wood 14 Under Attic(Unvented) ENTRY W IC 20 Blown 24 ft2 0.1 Wood 15 Under Attic(Unvented) CLST 20 Blown 16 ft2 0.1 Wood 16 Under Attic(Unvented) STUDY 20 Blown 156ft2 0.1 Wood 17 Under Attic(Unvented) UTILITY 20 Blown 135 ft2 0.1 Wood 18 Under Attic(U nvented) POWDER 20 Blown 24ft2 0.1 Wood 19 Under Attic(Unvented) HALL 20 Blown 76 ft2 0.1 Wood 20 Under Attic(Unvented) KITCHEN 20 Blown 225 ft2 0.1 Wood 21 Under Attic(Unvented) DINING 20 Blown 169 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ _ 1 E Exterior Concrete Block-Ext InsMASTER BE 5 16 0 10 0 160.0 ft2 0 0 0.6 0 2 S Exterior Concrete Block-Ext InsMASTER BE 5 15 0 10 0 150.0 ft2 0 0 0.6 0 3 W Exterior Concrete Block-Ext InsMASTER BE 5 16 0 10 0 160.0 ft2 0 0 0.6 0 4 E Exterior Concrete Block-Ext InsulM TOILET 5 4 0 10 0 40.0 ft2 0 0 0.6 0 5 E Exterior Concrete Block-Ext Insul M BATH 5 13 0 10 0 130.0 ft2 0 0 0.6 0 6 E Exterior Concrete Block-Ext InstSEDROOM 2 5 12 0 10 0 120.0 ft2 0 0 0.6 0 _ 7 E Exterior Concrete Block-Ext Insul BATH 2 5 6 0 10 0 60.0 ft2 0 0 0.6 0 8 N Exterior Concrete Block-Ext InstBEDROOM 3 5 12 0 10 0 120.0 ft2 0 0 0.6 0 9 E Exterior Concrete Block-Ext InsSEDROOM 3 5 13 0 10 0 130.0 ft2 0 0 0.6 0 10 N Exterior Concrete Block-Ext Insul WIC 3 5 6 0 10 0 60.0 ft2 0 0 0.6 0 11 W Exterior Concrete Block-Ext Insul WIC 3 5 8 0 10 0 80.0 ft2 0 0 0.6 0 12 N Exterior Concrete Block-Ext InsLIi? AY ROOM 5 5 0 10 0 50.0 ft2 0 0 0.6 0 13 S Exterior Concrete Block-Ext Ins61AMILY ROO 5 20 0 11 0 220.0 ft2 0 0 0.6 0 14 N Exterior Concrete Block-Ext Insul ENTRY 5 8 0 10 0 80.0 ft2 0 0 0.6 0 _15 N Exterior Concrete Block-Ext Insul CLST 5 4 0 10 0 40.0 ft2 0 0 0.6 0 16 N Exterior Concrete Block-Ext Insul STUDY 5 12 0 10 0 120.0 ft2 0 0 0.6 0 17 N Exterior Concrete Block-Ext Insul UTILITY 5 11 0 10 0 110.0 ft2 . 0 0 0.6 0 _18 W Exterior Concrete Block-Ext Insul UTILITY 5 11 0 10 0 110.0 ft2 0 0 0.6 0 19 S Exterior Concrete Block-Ext Insul POWDER 5 4 0 10 0 40.0 ft2 0 0 0.6 0 1/9/2018 8:58 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 20 W Exterior Concrete Block-Ext Insul POWDER 5 6 0 10 0 60.0 ft2 0 0 0.6 0 _21 S Exterior Concrete Block-Ext Insul HALL 5 4 0 10 0 40.0 ft2 0 0 0.6 0 _22 W Exterior Concrete Block-Ext Insul KITCHEN 5 15 0 10 0 150.0 ft2 0 0 0.6 0 23 E Exterior Concrete Block-Ext Insul DINING 5 4 0 10 0 40.0 ft2 0 0 0.6 0 24 S Exterior Concrete Block-Ext Insul DINING 5 15 0 10 0 150.0 ft2 0 0 0.6 0 25 W Exterior Concrete Block-Ext Insul DINING 5 12 0 10 0 120.0 ft2 0 0 0.6 0 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Single Yes 0.3 0.21 20.0 ft2 1 ft 6 in 1 ft 4 in None None 2 S 2 Metal Low-E Single Yes 0.3 0.21 40.0 ft2 1 ft 6 in 1 ft 4 in None None 3 W 3 Metal Low-E Single Yes 0.3 0.19 48.0 ft2 1 ft 6 in 1 ft 4 in None None. 4 E 5 Metal Low-E Single Yes 0.3 0.21 20.0 ft2 1 ft 6 in 1 ft 4 in None None 5 E 6 Metal Low-E Single Yes 0.3 0.21 20.0 ft2 1 ft 6 in 1 ft 4 in None None 6 E 7 Metal Low-E Single Yes 0.38 0.22 6.0 ft2 1 ft 6 in 1 ft 4 in None None 7 N 8 Metal Low-E Single Yes 0.3 0.21 20.0 ft2 1 ft 6 in 1 ft 4 in None None 8 E 9 Metal Low-E Single Yes 0.3 0.21 18.0 ft2 1 ft 6 in 1 ft 4 in None None 9 N 12 Metal Low-E Single Yes 0.3 0.21 20.0 ft2 1 ft 6 in 1 ft 4 in None None 10 S 13 Metal Low-E Single Yes 1.11 0.54 128.0 ft2 14 ft 0 in 1 ft 4 in None None 11 N 14 Metal Low-E Single Yes 0.3 0.19 48.0 ft2 1 ft 6 in 1 ft 4 in None None 12 N 16 Metal Low-E Single Yes 0.3 0.19 48.0 ft2 1 ft 6 in 1 ft 4 in None None 13 N 17 Metal Low-E Single Yes 0.3 0.21 12.0 ft2 1 ft 6 in 1 ft 4 in None None 14 W 18 Metal Low-E Single Yes 0.3 0.21 12.0 ft2 1 ft 6 in 1 ft 4 in None None 15 S 21 Metal Low-E Single Yes 0.3 0.19 .20.0 ft2 1 ft 6 in 1 ft 4 in None None 16 W 22 Metal Low-E Single Yes 0.3 0.21 12.0 ft2 1 ft 6 in 1 ft 4 in None None 17 W 22 Metal Low-E Single Yes 0.3 0.19 24.0 ft2 1 ft 6 in 1 ft 4 in None None 18 E 23 Metal Low-E Single Yes 0.3 0.21 18.0 ft2 1 ft 6 in 1 ft 4 in None None 19 S 24 Metal Low-E Single Yes 0.3 0.21 54.0 ft2 1 ft 6 in 1 ft 4 in None None T' 20 W 25 Metal Low-E Single Yes 0.3 0.21 18.0 ft2 1 ft 6 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000454 3058.4 167.9 315.77 .3313 7 1/9/2018 8:58 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2014 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:16 42 kBtu/hr 1260 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Exterior 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / --Supply— —Return-- Air CFM 25 CFM25 HVAC# �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 Attic 18 ft2 Default Leakage AHU (Default)c(Default)c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [[ ]]Jan Feb Mar Apr Ma Jun Jul Auge [ ]Oct Nov Dec Heatin [X]Jan Feb Mar E APr f May 4 Jun Jul jj Au Sep [ ]Oct X Nov Dec Ventin [[ ]]Jan Feb Mar [X]A r [ Ma [ Jun Jul Aug [ Se [X]Oct [X]Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling'(W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 6 1/9/2018 8:58 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HERNANDEZ RESIDENCE-MULLER RD Builder Name: JDL BUILDERS Street: 10105 MULLER ROAD Permit Office: ST LUCIE COUNTY City,State,Zip: FORT PIERCE,FL, Permit Number: Owner: DAN AND HEATHER HERNANDEZ Jurisdiction: Design Location: FL,Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/aftic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. 'Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 1/9/2018 8:58 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the EnergyPerformance Index, the more efficient the home. 10105 MULLER ROAD, FORT PIERCE, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=5.0 2540.00 ft2 b.N/A R= ftz 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. I' this a worst case? No 10.Ceiling Types Insulation Area a.Roof Deck(Unvented) R=20.0 2569.00 ft2 6. Conditioned floor area(ft2) 2569 b.N/A R= ft2 7. Windows*' Description Area c.N/A R= ft2 11.Ducts R ft2 a. U-Factor: Sgl,U=0.30 284.00 ft2 SHGC: SHGC=0.21 a.Sup:Attic,Ret:Attic,AH:AHU 6 175 b. U-Factor: Sgl,U=0.30 188.00 ft2 SHGC: SHGC=0.19 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Sgl,U=1.11 128.00 ft2 a.Central Unit 42.0 SEER:16.00 SHGC: SHGC=0.54 d. U-Factor: other(see details) 6.00 ft2 13.Heating systems kBtu/hr Efficiency SHGC: other(see details) a.Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 4.140 ft. Area Weighted Average SHGC: 0.274 8. Floor Types Insulation Area 14.Hot water systems Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2569.00 ft2 a.Electric EF:0.98 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building ,TNE Sp Construction through the above energy saving features which will be installed (or exceeded) �� _ �TF rin this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. 10 Builder Signature: Date: Add[ess of New Home: City/FL Zip: ,. ion WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/9/2018 8:58 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Job: ® Project Summary Date: Oct 12 2017 wri htsoft , 9 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@/\OL.COM Project • • For: HERNANDEZ RESIDENCE, JDL BUILDERS 10105 MULLER ROAD, FORT PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 28555 Btuh Structure 21813 Btuh Ducts 7654 Btuh Ducts 8922 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 36208 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 29198 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4420 Btuh Ducts 3038 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 2569 2569 Equipment latent load 7458 Btuh Volume(ft3) 26215 26215 Air changes/hour 0.32 0.16 Equipment total load 36656 Btuh Equiv.AVF(cfm) 140 70 Req. total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane • Trade Trade TRANE Model Cond 4TTR40431_1 AHRI ref Coil TEM6AOC6OH51++TDR+UF/HRZ AHRI ref 8858419 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 10.5 kW Sensible cooling 29400 Btuh Heating output 35692 Btuh Latent cooling 12600 Btuh Temperature rise 23 OF Total cooling 42000 Btuh Actual airflow 1400 cfm Actual airflow 1400 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.80 File Copy Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _A:_ + wrightsoft" 2017-Oct-12 12:41:39 Right-Suite®Universal 2017 17.0.08 RSU08101 Pagel ...umnets\Wrightsoft HVAC\HERNANDEZ-MULLER RD.rup Calc=MJ8 Front Door faces: N - Job: wrightsoft' Right-J®Worksheet Entire House Date: Oct 12,2017 BY: QUICK CALCS, INC. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Fa:c 772-466-6796 Email:QUICKCALCS a@/\OL.COM 1 Room name Entire House MASTER BEDROOM 2 Exposed wall 252.0 ft 47.0 ft 3 Room height 10.2 ft 10.0 It heat/cool 4 Room dimensions 1.0 x 275.0 ft 5 Room area 2569.0 ft2 275.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A,5ocs - -- - 0.125 n 3.50 1.91 580 - 432 1512 826 0 0 -�0 0 2 glazing,clr low-e 0.330 n 9.24 8.72 12 0 Ill 105 0 0 0 0 2 glazing,clr low-e 0.330 n 9.24 8.72 40 0 370 349 0 0 0 0 TEG_ 2 glazing,clr_lowwe _ _ _0.330 n- _ _ 9.24 _ 8.72 __ __96 , __ 0 __887 _ _ 837-_ _ _ _ 11 13A5ocs 0.125 a 3.50 1.91 680 578 2023 1105 160 140 490 268 2 glazing,clr low-e 0.330 a 9.24 22.25 6 0 55 133 0 0 0 0 2 glazing,cir low-e 0.330 a 9.24 22.25 20 0 185 445 20 0 185 445 2 glazing,clr low-e 0.330 a 9.24 22.25 40 0 370 890 0 0 0 0 2 glazinq,clr low-e _ ----0.330 e__ 9.24 22.25 _ - _36___ _ .0-- __333 .. _ 801 _ 0 __ __ _0_ _ _ 0 _ 0 13A5ocs 0.125 s 3.50 1.91 600 358 1253 685 150 110 385 210 2 glazing,clr low-e 0.330 s 9.24 8.72 40 40 370 349 40 40 370 349 2 glazing,clr low-e 0.330 s 9.24 8.72 54 54 499 471 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 20 20 g 85 174 0 0 0 0 _ - 2 glazing,_clr low-e-_ -----0.330 _s- 9.24 _ 8.72 _ 128____ 128 __1183 _ 1117 ___0 _0 0 _ -0 13A-5ocs 0.125 w 3.50 1.91 680 566 1981 1082 160 112 392 214 2 glazing,clr low-e 0.330 w 9.24 22.25 24 0 222 534 0 0 0 0 2 glazing,clr low-e 0.330 w 9.24 22.25 18 0 166 400 0 0 0 0 2 glazing,clr low-e 0.330 w 9.24 22.25 24 0 222 534 0 0 0 0 2gla2;inq,clrlow-e _0.330 _ w _ 9.24_ _22.25__- ___48 0 444 ____1068 __ _-_48 _ 0- 444 _ _ 1068 16A-3Omd__ __ __ 0.032__- 0.90 _ 2.24 _2569 _ 2569 _ 2302 5755_ 275- 275 _ 246 616 F 22A-tph 1.358 38.02 0.00 2569 252 9582 0 275 47 1787 0 6 c)AED excursion 0 73 Envelope loss/gain 24252 17661 4298 3243 12 a) Infiltration 4302 1152 796 213 b) Room ventilation 0 0 01 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 3000 0 Subtotal(lines 6 to 13) 28555 21813 5095 3456 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 28555 21813 5095 3456 15 Duct loads 1 27% 41%1 7654 8922 27% 41%1 1366 1413 Total room load 36208 30735 6460 4869 Air required(cfm) I 1 1 1400 14M1 250 222 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ACCA' wrigFftsoft' 2017-Oct-12 1 Right-Suite®Universal 2017 17.0.08 RSU08101 P 1 Page ...umnets\Wdghtsoft WAC\HERNANDEZ-MULLER RD.rup Calc=MJ8 Front Door faces: N 9 wrightsoft, Right-M)Worksheet Job: Entire House Date: Oct 12,2017 QUICK CALCS, INC. By: 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@/\OL.COM 1 Room name M TOILET M WIC 2 Exposed wall 4.0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 10.0 x 4.0 ft 7.0 x 10.0 ft 5 Room area 40.0 ft2 70.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2--°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VIJ - 13A-5ocs 0.330 n 9.24 1.72 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 n 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 n 9.24 8.72 0 0 0 0 0 0 0 0 2-glazing,.clr lower 0.330 n 9.24. 8.72. 0 _ _ 0 0 0 _ 0 0 _ 0 0 • 11 13A-5ocs 0.125 a 3.50 1.91 40 40 140 76 0 0 0 0 2 glazing,cir low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2glazinq,cir low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 13A-5ocs 0.125 s 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e_ 0.330 s 9.24 8.72 0 0 0 0 _ 0 0 0 0 13A-5ocs 0.125 w 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazinq,clr low-e 0.330 w 9.24 _ 22.25 0 0 0 0 0 0 _ 0 0 C _ _ 16A-30md_ __0.032 0.90__ 2.24 40 _ 40 36 90 70 70 63 157 F 22?rtph 1.358 38.02 0.00 40 4 152 0 70 0 0 0 6 c)AED excursion -7 -6 Envelope loss/gain 328 159 63 151 12 a) Infiltration 68 18 0 0 b) Room ventilation 0 01 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 396 177 63 151 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 396 177 63 151 15 Duct loads 27% 41% 106 72 27% 41% 17 62 Total room load 502 250 80 213 Air required(cfm) 19 11 3 10 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _'Q__ _Fk wri offt ghts 2017-Oct-1212:41:39 Right-Suited Universal 2017 17.0.08 RSU08101 Page 2 ..umnets\Wrightsoft WAC\HERNANDEZ-MULLER RD.rup Calc=MJ8 Front Door faces: N + -wrightsoft= Right-.10 Worksheet Job: Entire House Date: Oct 12,2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Farc 772-466-6796 Email:QUICKCALCS OL.COM 1 Room name M BATH BEDROOM 2 2 sed wall 13.0 ft 12.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 10.0 x 13.0 ft 12.0 x 12.0 ft 5 Room area 130.0 ft2 144.0 ft2 • Ty Construction LI-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft;°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 2 glazing, 0.330 n 9.24 1.7 0 0 0 0 0 0 0 0 I���GG 2 glazing,cir lower 0.330 n 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 n 9.24 8.72 0 0 0 0 0 0 0 0 ___ 2 glazing,cir-lower. __ 0.330 n_ _ 9.24 _ 8.72 _ 0 _0 _ 0 0- _ 0 0 0 0 11 13A-5ocs 0.125 a 3.50 1.91 130 110 385 210 120 100 350 191 2 glazing,cir low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 a 9.24 22.25 20 0 185 445 20 0 185 445 2 glazinq,cir low-e _ _ _ 0.330 a 9.24 22.25 _0 _ _ _0 0 0 0 0- 0 _ 0 13A 5ocs 0.125 s 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,cir low-e_ 0.330 s _ _ 9.24 8.72 0 _ -0 _ __ 0 _0 _ 0 _ _ 0 _ 0 0 13A5ocs 0.125 w 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e_ _ 0.330 w 9.24_ 22.25 0 0 0 0 0 0 0 0 C _ 16A-30md_ _ _ _ 0.032 _ - _ _ 0.90 130 130_ 2.24 _ _116 291 144 144 129 _323 F 22A-tph 1.358 38.02 0.00 130 13 494 0 144 12 456 0 4. 6 c)AED excursion 0 -P7 Envelope loss/gain 1181 947 1120 932 12 a) Infiltration 220 59 203 54 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 700 Subtotal(lines 6 to 13) 1401 1006 1323 1687 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1401 1006 1323 1687 15 Duct loads 27% 41% 375 411 27% 41%1 355 690 Total room load 1776 1417 1678 2376 Air required(cfm) 69 65 65 108 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft" Right-Suite®Universal 2017 17.0.08 RSU08101 2017-Oct-12 12:41:39 AC�A ...umnets\Wrightsoft HVAC\HERNANDEZ-MULLER RD.rup Calc=MA Front Door faces: N Page 3 i +�-wrightsoft' Right-J®Worksheet Job: Entire House Date: Oct 12,2017 QUICK CALCS, INC. By: 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772466-6799 Fax 772-466-6796 Email:QUICKCALCS AOL.COM 1 Room name WIC 2 BATH 2 2 Exposed wall 0 ft 6.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 5.0 x 5.0 ft 12.0 x 6.0 ft 5 Room area 25.0 ftz 72.0 ft' Ty Construction Ll-value Or HTM Area (ft') Load Area (ft) Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vy 13A5ocs 6T:E5 n 3.50 - 1.91 - - 0- '- _O____-_ 0 -____ 6 _0 ___0 -00- 2 glazing,clr low-e 0.330 n 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 n 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e ----_-__0.330 -n---9.24 8.72_______0-_-_---0____0 0- 0-_- 0 __- _0 _ 0- 11 13A-5ocs 0.125 a 3.50 1.91 0 0 0 0 60 54 189 163 2 glazing,clr low-e 0.330 a 9.24 22.25 0 0 0 0 6 0 55 133 2 glazing,clr low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 a 9.24 22.25 0 0 0. 0 0 0 0 0 _ -- -2 glazinq,clr-low-e-- -__.__0.330--e-- --- 9.24.-_22.25 _____.___0 -----._0- ------ 0 - -0 _.. _ -----_ -- 0 0---- 0 - - 0 13A Socs 0.125 s 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 -2 glazing,.clr_low-e___ _____0.330_ s- _ _-9.24-___8.72 __0___ ___0 _- __._0_.___ ___0 __ _0 13A5ocs 0.125 w 3.50 1.91' 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low_e _-_ _ _0.330-w 9.24 22.25 0 �__0 _ 0 __-_ 0 _ 0 0 _ 0 _ 0 _ -- OA32 - _ 0.90 2,24_ 25- 25 _ 22 _ _56_ `72 `72_ 65 1_61_ F 22A-tph T _ 1.358 - 38.02 0.00 25- 0 - 0" 0 72 6 228 0 77 6 c)AED excursion -2 -7 Envelope loss/gain 22 54 537 391 12 a) Infiltration 0 0 102 27 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 22 54 639 418 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 22 54 639 418 15 Duct loads 27% 41% 6 22 27% 41% 171 171 Total room load 28 76 810 589 Air required(cfm) 1 3 1 1 311. 27 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrightsoft' Right-Suite®Universal 2017 17.0.08 RSU08101 2017-Oct-12 12:41:39 ACCN ...umnets\Wrightsoft HVAC\HERNANDEZ-MULLER RD.rup Calc=MJ8 Front Door faces: N Page 4 -r�- wrightsoft Right-J®Worksheet Job: Entire House Date: Oct 12,2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772466-6799 Fax 772466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BEDROOM 3 WIC 3 2 Eqjosed wall 25.0 ft 14.0 ft 3 Room height 10.0 ft - heat/cool 10.0 ft heat/cool 4 Room dimensions 12.0 x 13.0 ft 6.0 x 8.0 ft 5 Room area 156.0 ft2 48.0 ft2 • Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross I N/P/S Heat Cool 6 V�/ 13A-5ocs 0.125 n 3.50- 1.91 120 100 - 350 191 65 - -60 210 - -115 2 glazing,cir low-e 0.330 n 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 n 9.24 8.72 20 0 185 174 0 0 0 0 2 glazing,cir low�e_ ___--0.330_ n 9.24 __8.72-_--__0_-- _ 0 --..0 -- 0 _ _0 _ __-_ 0 _ _ 0 11 13A-5ocs 0.125 a 3.50 1.91 130 112 392 214 0 0 0 0 2 glazing,cir low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 _ 2 glazinq,clr low_e_ _ _ _ 0.330 _e_ 9.24 _ 22.25 18_ _ _ 0 _ 166_ _ 400 _0 _ 0 _0 0 13A 5ocs 0.125 s 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2glazing,clrlow--e -_ __0.330 _s _ ___9.24__-_8.72 ----___0_____ _ _0 .__ 0- 0 ._ .0_ ___ __0 _ A. _ _.. 0 13A5ocs 0.125 w 3.50 1.91 0 0 0 0 80 80 280 153 2 glazing,cir low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazinq,clr low-e_ _ _-_- __0.330--w -- 9.24-22.25 _ ,_0 _ _ _0 -- ___0 _ -- 0 .. 0 _ 16A-30md -_- 0.032_ 0.90 ____2.24__-___156 156 ____140 _349 43 _ _108 ---- �-1.358 - 38.02 0.00 156 25 951 0 -----48 14 532 0 6 c)AED excursion -74 -17 Envelope loss/gain 2183 1256 1065 359 12 a) Infiltration 423 113 237 64 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 0 Subtotal(lines 6 to 13) 2607 1869 1302 422 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2607 1869 1302 422 151 Duct loads 27% 41% 699 765 27% 41% 349 173 Total room load 3306 2634 1652 595 Air required(cfm) 128 120 64 27 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -7-A � wr-tghtsoft` Right-Suite®Universal 2017 17.0.08 RSU08101 2017-Oct-12 12:41:39 Page 5 ...umnets\Wrightsoft HVAC\HERNANDEZ-MULLER RD.rup Calc=MJB Front Door faces: N i g wrightsoft Ri-�- ht-J®Worksheet Job: Entire House Date: Oct 12,2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@�40L.COM 1 Room name PLAY ROOM FAMILYROOM 2 Exposed wall 5.0 ft 20.0 ft 3 Room height 10.0 ft heat/cool 11.0 ft heat/cool 4 Room dimensions 11.0 x 13.0 ft 1.0 x 525.0 ft 5 Room area 143.0 ft2 525.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/W-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 LL// 13A-5ocs _ 0.125 n 3.50 1.91 50 30 105 57 0 0 0 0 I--G 2 glazing,clr low-e 0.330 n 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 n 9.24 8.72 20 0 185 174 0 0 0 0 2 glazing,clr low-e 0.330 n 9.24-- 8.72 0 _0 0 0 0 0 _ _ ___0 0 11 13A5ocs 0.125 a 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazinq,clr low-e 0.330 a 9.24_ 22.25 0 0 _0 0 0 0 0 _ 0 0 13A-5ocs 0.125 s 3.50 1.91 _0 0 0 0 220 92 322 176 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2.glazing,clr low- 0.330 s 9.24 8.72 0 0 0 0 128 128 1183 1117 13A-5ocs 0.125 w 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 qlazinq,c_Ir low- 0.330 w 9.24_ 22.25 0 0 0 0 0 0 0 0 C 16A-30m_d _ _ _0.032 0.90 _ 2.24 143_ 143 128 320 _ 525 525 _ 470 1176 F 22A-tph 1.358 38.02 0.00 143 5 190 0 525 20 760 0 6 c)AED excursion 56 -67 Envelope loss/gain 608 496 2736 2401 12 a) Infiltration 85 23 373 100 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 900 900 Subtotal(lines 6 to 13) 693 1419 3108 3401 Less a)denial load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 201 96 56 48 14 Subtotal 894 1515 3164 3449 15 Duct loads 27% 41% 240 620 27% 41% 848 1411 Total room load 1133 2135 4012 4860 Air required(cfm) 44 97 155 221 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ACCA�'� wf IghtSoTt` Right-Suite®Universal 2017 17.0.08 RSU08101 2017-Oct-12 1 Page 6 ...umnets\Wdghtsoft WAC\HERNANDEZ-MULLER RD.rup Calc=MJ8 Front Door faces: N g i - - wrightsoft Right-J®Worksheet Job: Enure House Date: Oct 12,2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name ENTRY AHU 2 F)q3osed wall 8.0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 8.0 x 13.0 ft 4.0 x 3.0 ft ft 5 Room area 104.0 ' 12.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft') Load number (Btuh/ftz°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-52glazins 0.330 n 9.24 1.7 80 32 112 61 0 0 0 0 2 glazing,clr lower 0.330 n 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 n 9.24 8.72 0 0 0 0 0 0 0 0 -_--_2.glazing,clr low_e __ ___0.330 n_ 9.24.___ 8.72 --_ ___48. --_ 0, _-.__444_ 419-_- ___ 0___ -0_-- _--_0_-- _-- 0 11 13A5ocs 0.125 a 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazinq,clr lower 0.330 e_ 9.24 22.25 _ 0 0 0 0 _ 0 _0 0 _ - _ 0 13A-5ocs 0.125 s 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e_ 0.330 s 9.24 8.72 _ 0 __ - 0 .0 0 _ 0 0 _ 0 _ 0 13A-5ocs 0.125 w 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazinp,_clr low-e_ _ 0.330 w_ 9.24 22.25 0 0 _ 0 0 0 0 0 0 C' 16A-30md_ _ 0.032 0.90 2.24 104 104 _ _ 93 -233 12_ 12 11 27 F` 22A4tph- -- _-1.358 38.02 0.00 - _104 - 8 :SO4 0 12 - 0- 0_ - _ -0 6 c)AED excursion -28 -1 Envelope loss/gain 953 684 11 26 12 a) Infiltration 136 36 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1088 721 11 26 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 201 96 -11 -26 14 Subtotal 1289 817 0 0 15 Duct loads 27% 41% 346 334 27'/6 41% 0 0 Total room load 1635 1151 0 0 Air required(cfm) 63 52 0 0 Calculations approved b ACCA to meet all requirements of Manual J 8th Ed. PP Y eQ -off- Wr'ightSOft" Right-Suite®Universal 2017 17.0.08 RSU08101 2017-Oct-12 12:41:39 �� ...umnets\Wdghtsoft WAC\HERNANDEZ-MULLER RD.rup Calc=MJ8 Front Door faces: N Page 7 -�+ wrightsot Right-J®Worksheet Job: Entire House Date: Oct 12,2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@AOL.COM 1 Room name ENTRY W IC CLST 2 Erq)osed wall 0 ft 4.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 4.0 x 6.0 ft 4.0 x 4.0 ft 5 Room area 24.0 ft2 16.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft-) Load number (Btuhlft;°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VVjj// 13A 5ocs 0.125 n 3.50 1.91 0 0 0 0 40 40 140 76 I--G 2 glazing,cir low-e 0.330 n 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 n 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,cir_low-e _ 0.330 n 9.24 9.72 0 _ 0_ 0 _ 0 _0 0. _ 0 _ 0 11 13A-5ocs 0.125 a 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 alazinq,clr low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 13A•5ocs . 0.125 s 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 s 9.24 8.72 0 _ 0 0 0 0 0 0 0 13A-5ocs 0.125 w 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr lower_ 0.330 w 9.24_ 22.25 0 _ 0_ 0 0 0 0 0 0 C_-_ 16A30md_. __ 0.032 0.90 2.24 24 24 22_ 54 16 16 14 36 F 22Fk7tph 1.358 38.02 0.00 '24 0 0 0 16 4 152 0 - - - - - - - - --- - - - - -- - 6 c)AED excursion -2 -5 Envelope loss/gain 22 52 306 107 12 a) Infiltration 0 0 68 18 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 22 52 374 126 Less eAemai load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -22 -52 -374 -126 14 Subtotal 0 0 0 0 15 Duct loads 27% 41% 0 0 27% 41% 0 0 Total room load 0 0 0 0 Air required(cfm) 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2O17-Oct-12 12:41:39 RightSuite®Universal 2017 17.0.08 RSU08101 Page 8 ...umnets\Wrightsoft WAC\HERNANDEZ-MULLER RD.rup Calc=MJ8 Front Door faces: N -wrightsoft' Right-M Worksheet Job: Entire House Date: Oct 12,2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772466-6799 Fax 772-466-6796 Email:QUICKCALCS AOL.COM 1 Room name STUDY UTILITY 2 Fposed wall 12.0 It 22.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 12.0 x 13.0 ft 1.0 x 135.0 ft 5 Room area 156.0 ft' 135.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft) Load number (BtutVf?°F) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 _ 13A-5ocs _ - _ 0.125 n 3.50 1.91 120 _ - 72 252 138 110 98 343 187 2 glazing,clr low-e 0.330 n 9.24 8.72 0 0 0 0 12 0 111 105 2 glazing,clr low-e 0.330 n 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e ___--- --0.330 n _ _ 9.24.--_ 8.72-_- _ _48_ _ ._ 0 _ __-.4 _4 44 419, -._.- --0 _ ----0_ -- 11 13X5ocs 0.125 a 3.50 1.91 0 0 0 0 0 0 C1 0 2 glazing,clr low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 _ 2 glazinq,clr low- 0.330 e__ 9.24 22.25 _ 0- 0 _ _0 0 0 0 0 0 13A-5ocs 0.125 s 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2glazing,clr.low-e _ 0.330 s_ 9.24. _ 8.72 _ _0 _ 0 0 -0 0 -0- - 0 0 13A-5ocs 0.125 w 3.50 1.91 0 0 0 0 110 98 343 187 2 glazing,cir low-e 0.330 w 9.24 22.25 0 0 0 0 12 0 111 267 2 glazing,clr low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 w 9.24 22.25 0 0 0 0 C_ -0 0 0 0 0.032 0.90 2.24 156 156 _ 135 135_ 16A-30md - -- _ _ _ _ _ -__ _ _140 _ -349 - - - -__ _ _ _ __ 121 _ 302 F 22A-tph 1.358 38.02 0.00 156 12 456 0 135 22 837 0 6 ' c)AED excursion -36 60 Envelope loss/gain 1292 869 18651 1109 12 a) Infiltration 203 54 373 100 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1495 924 2238 1209 Less ekemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 155 113 90 66 14 Subtotal 1650 1037 2328 1275 15 Duct loads 27% 41% 442 424 27% 41% 624 521 Total room load 2092 1461 2952 1796 Air required(cfm) 81 671 1 114 82 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �A Wrightsoft' 2017-Oct-12 1 Right-Suite®Universal 2017 17.0.08 RSU08101 Page ae 9 ...umnets\Wdghtsoft WAC\HERNANDEZ-MULLER RD.rup Cale=MJ8 Front Door faces: N 9 +wrightsoft' Right-J®Worksheet Job: Entire House Date: Oct 12,2017 QUICK CALCS, INC. By. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@!AOL.COM 1 Room name POWDER HALL 2 Exposed wall 10.0 ft 4.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 4.0 x 6.0 ft 19.0 x 4.0 ft 5 Room area 24.0 ft2 76.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuhfft'°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool i Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 y! 13A 5ocs 0.125 n 3.50 - 1.91 - `- _00 0 0 0 0-- _0 2 glazing,clr low-e 0.330 n 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 n 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr.low-e--- __ --_0.330 n 9.24.. _3.72 --._-9_-- _ __0 ___--_0__ _-_-_0 _--0-- -_ -0-._ 11 - 13A-5ocs 0.125 a 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2Alazinq,_clr low-e -------- 0.330 e _ 9.24_ __22.25_ - _ 0 .- _ _0 -- - 0_ ___ 0 - - - 0 --- - 0 -------_0 -__.- 0 13A5ocs 0.125 s 3.50 1.91 40 40 140 76 40 20 70 38 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 20 20 185 174 2 glazing,clr-low-e___ ___ 0.330 s _ 9.24 _ 8.72 0 0 '___0 _0 __ _ 0 -0 _ _ 0 _ 0 13A-5ocs 0.125 w 3.50 1.91 60 60 210 115 0 0 0 0 2 glazing,clr low-e 0.330 w 9.24 22.25 0 0 0 .0 0 0 0 0 2 glazing,clr low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 w 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 w 9.24 __22.25- _ 0- __ _ _0 _ __ _ -0 0 16A-30md_-_______ _ 0.032 _ - ___ 0.90- 2.24_ __-24 _ 24__- -22 54_ _76 _76 __ 68 _ 170 F 22A-tp 1.358 - 38.02 0.00 24 10 380 0 76 4 152 0 6 c)AED excursion -11 -5 Envelope loss/gain 752 234 475 378 12 a) Infiltration 169 45 68 18 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 921 279 543 396 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 52 38 -543 -396 14 Subtotal 973 317 0 0 15 Duct loads 27% 41% 261 130 27% 41% 0 0 Total room load 1234 447 0 0 Air required(cfm) 48 20 1 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrigtratsOft' g Right-Suite@ Universal 2017 17.0.08 RSUD8101 2017-Oct-12 Page 10 m...unets\Wrightsoft WAC%HERNANDEZ-MULLER RD.rup Calc=MA Front Door faces: N i -wrightsoft Right-J®Worksheet Job: Entire House Date: Oct 12,2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name KITCHEN DINING 2 Exposed wall 15.0 ft 31.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 15.0 x 15.0 ft 1.0 x 169.0 ft 5 Room area 225.0 ft2 169.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuhlft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool ' 6 ------ 18A-5ocs -_ _ - -- - 0.126 n 3.50--- 1.91 - -- -- 0 - --- 0 ---- - 0 0 - - 0 - -0 - 0 - 0 --G 2 glazing,clr low-e 0.330 n 9.24 8.72 0 0 0 0 0 0 0 0 1�_GG 2 glazing,clr low-e 0.330 n 9.24 8.72 0 0 0 0 0 0 0 0 2.glazing,_c(r_low-e -- _0.330 -0 ---9.24 --8.72.__ _0 - 0 __-_..0 _0-- _0 - - 6 - - -0 �._ - 0 11 13A-5ocs 0.125 a 3.50 1.91 0 0 0 0 40 22 77 42 2 glazing,clr low- 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 a 9.24 22-25 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 a 9.24 22.25 0 0 0 0 0 0 0 0 2 glazinp._clr low-e - -- - 0.330 _e 9.24 22.25_ __._ __0 -_-__ 0 - _ _.-0 0- -- -18-- -- -0 - -- 166 _ 400 • 13A5ocs 0.125 s 3.50 1.91 0 0 0 0 150 96 336 184 2 glazing,cir low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 54 54 499 471 2 glazing,clr low-e 0.330 s 9.24 8.72 0 0 0 0 0 0 0 0 _ 2 glazing,.cir_low-e_ _ _..0.330 _s 9.24____ 8.72 ____,_0 ___ _ 0 -_- -0 _0 .-- _ -0 _____ 0 ___-_ _ 0 __ 0 13A5ocs 0.125 w 3.50 1.91 150 114 399 218 120 102 357 195 2 glazing,clr low-e 0.330 w 9.24 22.25 12 0 111 267 0 0 0 0 2 glazing,clr low-e 0.330 w 9.24 22.25 0 0 0 0 18 0 166 400 2 glazing,clr low-e 0.330 w 9.24 22.25 24 0 222 534 0 0 0 0 2 plazinp,clr low e__ __-0.330 _w - 9.24 _- 22.25_.-_-.-_0------0--- ---9 --0 --.--- --0 ---- --0-- -- 0 �_. --0 01-- ,16A-Mmd_-__ _ _ __0.032 _.-_ 0.90_-_2.24 _ ___225__ 226 ___._202 __ _504 _ _ 169-_ _169 _ 151_ _.__ 379 F 22A tph 1.358 38.02 0.00 225 15 570 0 169 31 1179 0 6 c)AED excursion 303 -84 Envelope loss/gain 1504 1825 2932 1987 12 a) Infiltration 254 68 525 141 b) Room ventilation 0 0 01 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal.(lines 6 to 13) 1758 1894 3457 2128 Less a)denial load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 194 141 0 0 14 Subtotal 1952 2035 3457 2128 15 Duct loads 127% 41% 523 832 27% 41% 927 870 Total room load 2475 2867 4383 2998 Air required(cfm) 96 131 169 137 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. ACCA' wrightsoft" Right-Suite®Universal 2017 17.0.08 RSU08101 2017-Oct-12 1age 11 ...umnets\Wrightsoft HVAC%HERNANDEZ-MULLER RD.rup Calc=MJ8 Front Door faces: N 9 Duct System Summary Job: �=�+-, wrightsoft, y Date: Oct 12,2017 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE,FORT PIERCE,FL 34946 Phone:772466-6799 Fax 772466-6796 Email:QUICKCALCS AOL.COM -Project • • For. HERNANDEZ RESIDENCE, JDL BUILDERS 10105 MULLER ROAD, FORT PIERCE, FL Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply/return available pressure 0.500/0.500 in H2O 0.500/0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 1400 cfm 1400 cfm Total effective length(TEL) 203 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk BATH 2 h 810 31 27 1.000 5.0 Ox 0 VIFx 16.2 115.0 st2 BEDROOM 2 C 2376 65 108 1.000 7.0 Ox 0 VIFx 27.3 135.0 st4 BEDROOM 3 h 3306 128 120 1.000 7.0 Ox 0 VIFx 18.2 115.0 st2 DINING h 4383 169 137 1.000 7.0 Ox0 VIFx 36.7 135.0 st3 ENTRY h 1635 63 52 1.000 6.0 Ox0 VIFx 18.9 115.0 st1 FAMILY ROOM C 2430 78 111 1.000 7.0 Ox0 VIFx 47.4 155.0 st5 FAMILY ROOM-A c 2430 78 111 1.000 7.0 Ox0 VIFx 31.2 135.0 st4 KITCHEN C 2867 96 131 1.000 7.0 Ox 0 VIFx 34.9 135.0 st3 M BATH h 1776 69 65 1.000 6.0 Ox 0 VIFx 42.4 155.0 st5 M TOILET h 502 19 11 1.000 4.0 Ox0 VIFx 43.3 155.0 st5 M WIC c 213 3 10 1.000 4.0 Ox0 VIFx 28.6 135.0 st4 MASTER BEDROOM h 3230 125 111 1.000 T.0 Ox0 VIFx 48.3 155.0 st5 -MASTER BEDROOM-A h 3230 125 111 1.000 7.0 Ox 0 VIFx 46.9 155.0 st5 PLAYROOM c 2135 44 97 1.000 7.0 Ox0 VIFx 14.0 115.0 st2 POWDER h 1234 48 20 1.000 5.0 Ox0 VIFx 29.3 115.0 st1 STUDY h 2092 81 67 1.000 6.0 Ox0 VIFx 15.9 115.0 st1 UTILITY h 2952 114 82 1.000 6.0 Ox0 VIFx 27.0 115.0 st1 WIC 2 c 76 1 3 1.000 4.0 Ox 0 VIFx 27.0 135.0 st4 WIC h 1652 64 27 1.000 5.0 Ox0 VIFx 18.8 115.0 st2 1 wrl htsoft° 2017-Oct-1212:41:41 9 Right-Suite®Universal 2017 17.0.08 RSU08101 Page 1 �+� ...umnets\Wrightsoft WAC\HERNANDEZ-MULLER RD.rup Calc=MJ8 Front Door faces: N Supply Trunk Detail • - Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st5 Peak AVF 415 408 1.000 762 10.0 0 x 0 VinlFlx st4 st4 Peak AVF 562 640 1.000 815 12.0 0 x 0 VinlFlx st2 st2 Peak AVF 829 912 1.000 853 14.0 0 x 0 VinlFlx st3 Peak AVF 265 267 1.000 605 9.0 0 x 0 VinlFlx st1 st1 Peak AVF 571 488 1.000 865 11.0 0 x 0 VinlFlx Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Matl Trunk rb1 Ox 0 1400 1400 0 0 0 0 Ox 0 VIFx 9 wrl htsoft, 2017-Oct-12 12:41:41 �� _f Right-Suite®Universal 2017 17.0.08 RSU08101..umnets\Wrightsoft WAC\HERNANDEZ-MULLER RD.rup Calc=MJ8 Front Doorfaces: N Page 2