Loading...
HomeMy WebLinkAboutCertification for Design Load Compliance `J: Planning_&Development Services Department • ! Building&Code Regulations Division D ' 2300 Virginia Avenue,Fort Pierce,FL 34982—(772)462-1553 Certification-f r �Design_ C'�� load'Cd71i'Ylpl1aCIiGe Project Name: Hernandez Residence Project Address: 101'05 Muller Rd, Ft. Pierce, FL PCN#'2334-700-0003-2' Permit: OccupaneyT.Vpe: Constructiom-Type: ,�-.MSi'RUC 10WS F.OR-USE. • This certification must'be completed,sagrned,and sealed:by the design,professiarnal;.of reco,rd'. 0 Submit(2)icopies.for residential,43:)copiesfor commercial with all-permit applications°invo[ving.the.fol[bwina.:: o ,New Residences(single or mufti-family) o ..ResWential.Addition r, •Any zrrpSsnrv,:;SI.Y�acialra rpr�u�rina.a.hciilrling•[larrriit o Any.non-reMdential.structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: Ccamalete.all that apply). 1. DESIGN CODE: Florida S'A-J-_c► Code Fifth Edition with 205upplements using ASCE 7-10 2. 5tructu, ^es g led;as(check one): ^closed l?tirtiu!!;y Enclosew open 3. Risk Category: _F -X if [it iU Exposure:Category: B.. )<C' D'- 4. Design Wind Velocity __]_(a_Q—mph __)�.ASD LRFD End Zone Width: 'S 60 ft 5. Mean;.Roof Height .d ft Roof Pitch: :12 Parapet:1-4 1ft 6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft RIITM H,clearly label on all plan openings): Zone 1: ,3 t Zone 2,:/— 6� Zme 3,: —66 Zane 4: 3�{ 3 k Zon e s:1=3 6 Garage:_/, }` 7. Design Loads: Floor: `?.d NSF Roof/.,Dead: NSF Roc;f/Live.Zap 4d &2icony�: 1� {, psi: Dodo: ___PSF Deck: PSF stairs: _P5F Fence: �!/lam PSF Railings: PSF 8. Were Shear Walls Considered.For Structure? Yes: ,Not Applicable. Explain Why Not: 9. Is A Continuous Load.Path Provided? Yes 'Not Applicable Explain Why Not: 10. -Design Soif gearing"Pressure.: 95f . Soil Test Rt-ports Submitted? yes - - Dt, ,Jo—J Ky1(Oc/ DESIGN-PROFESSIONAL"CERTtFir—AT[Of4 STATEMEN 1 certify that, to:the best of my•knowledge and belief,..the attached,plans.& specifications have.been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on,these plans provide adequate resistance to the design forces specified: _ WAJ 62F_StJELL_ lee Print I/_Ylarne j Cert#f2�Co.Cerr with- > l:l(C c'1 1,.�.� C �J�t S�/u tr 4�U • 3),eye a��•� ,'7T I 3 - nature, Date,and Seal ' `� f� ��' V L1gi,.I ,41Ec S 7`vAY-(- E=L 3 LJ f J)- / J Company Name&Address Revised 07/25/20i4