HomeMy WebLinkAboutPRODUCT APPROVAL7/23/2021 Florida Building Code Online
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Masonite International
1955 Powis Road
West Chicago, IL 60185
(800) 663-3667
sschreiber@masonite.com
Steve Schreiber
sschreiber@masonite.com
Exterior Doors
Swinging Exterior Door Assemblies
Certification Mark or Listing
National Accreditation & Management Institute
National Accreditation & Management Institute
Standard
TAS 201
TAS 202
TAS 203
Method 1 Option A
11/05/2020
11/05/2020
11/11/2020
Year
1994
1994
1994
Summary of Products
FL # Model, Number or Name Description
https:/AmAw.floridabuiIding.org/pr/pr app dtl.aspx?param=v,GEVXQvADgs3M6m9%2fK8XPIOX7\28VVDoO3rKdgwOBugQacWmDBFHOng%3d%3d
1 /4
7/23/2021
Florida Building Code Online
22378.1 Stormguard Fiberglass Side -Hinged Door 6'-8" Opaque I/S Single Door
Unit
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22378 R7 C CAC NI007077.07-R3.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
12/31/2025
Design Pressure: +60/-65
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22378 R7 II FL0170.pdf
Building Code, including the High Velocity Hurricane Zone, and
Verified By: National Accreditation & Management Institute
where pressure requirements do not exceed the design pressures
Created by Independent Third Party:
listed. 3'-0" x 6'-8" max nominal size. Hurricane protective system
Evaluation Reports
is NOT required. See DWG-MA-FLO170 for anchor details and water
FL22378 R7 AE 514010B.pdf
performance where required.
FL22378 R7 AE 514014B.pdf
Created by Independent Third Party: Yes
22378.2
Stormguard Fiberglass Side -Hinged Door
Unit
6'-8" Opaque O/S Single Door
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22378 R7 C CAC NI007077.07-R3.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
12/31/2025
Design Pressure: +60/-60
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22378 R7 II FL0170.pdf
Building Code, including the High Velocity Hurricane Zone, and
Verified By: National Accreditation & Management Institute
where pressure requirements do not exceed the design pressures
Created by Independent Third Party:
listed. 3'-0" x 6'-8" max nominal size. Hurricane protective system
Evaluation Reports
is NOT required. See DWG-MA-FLO170 for anchor details and water
FL22378 R7 AE 514010B.pdf
performance where required.
FL22378 R7 AE 514014B.pdf
Created by Independent Third Party: Yes
22378.3 Stormguard Fiberglass Side -Hinged Door 6'-8" Opaque I/S Single or Double Door w/ or w/o Sidelites
Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +50.5/-50.5
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design pressures
listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system
is NOT required. See DWG-MA-FLO170 for anchor details and water
performance where required.
Certification Agency Certificate
FL22378 R7 C CAC NIO07077.07-R3.pdf
Quality Assurance Contract Expiration Date
12/31/2025
Installation Instructions
FL22378 R7 II FL0170.pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22378 R7 AE 514008B.pdf
FL22378 R7 AE 514012B.pdf
Created by Independent Third Party: Yes
22378.4 Stormguard Fiberglass Side -Hinged Door 6'-8" Opaque O/S Single or Double Door w/ or w/o Sidelites
Unit
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22378 R7 C CAC NI007077.07-R3 pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
12/31/2025
Design Pressure: +55.0/-50.5
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22378 R7 II FL0170.pdf
Building Code, including the High Velocity Hurricane Zone, and
Verified By: National Accreditation & Management Institute
where pressure requirements do not exceed the design pressures
Created by Independent Third Party:
listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system
Evaluation Reports
is NOT required. See DWG-MA-FLO170 for anchor details and water
FL22378 R7 AE 514008B.pdf
performance where required.
FL22378 R7 AE 514012B.pdf
Created by Independent Third Party: Yes
22378.5 Stormguard Fiberglass Side -Hinged Door 6'-8" Impact Glazed I/S or O/S Single Door w/ or w/o Sidelites
Unit
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22378 R7 C CAC NI007077.09-114.pi f
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
12/31/2025
Design Pressure: +55/-55
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22378 R7 II 1`1_0172.pdf
Building Code, including the High Velocity Hurricane Zone, and
Verified By: National Accreditation & Management Institute
where pressure requirements do not exceed the design pressures
Created by Independent Third Party:
listed. 9'-0" x 6'-8" max nominal size. Hurricane protective system
Evaluation Reports
is NOT required. See DWG-MA-FLO172 for anchor details and water
FL22378 R7 AE 514008B.pd
performance where required.
FL22378 R7 AE 514012B,pdf
Created by Independent Third Party: Yes
22378.6 I St Unit nuard Fiberglass Side -Hinged Door 6'-8" Impact Glazed I/S Double Door w/ or w/o Sidelites
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: Yes FL22378 R7 C CAC NI007077 09-R4 pdf
Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: Yes 12/31/2025
Design Pressure: +50/-55 Installation Instructions
Other: Evaluated for use in locations adhering to the Florida FL22378 R7 II FL0172.pdf
https:/AmA w.floridabul Idi ng .org/pr/pr__app_dtl.aspx?param=wGE\/XQwtDq s3M 6mg`/`2f <8XPIOX7\t28WDoO3rKdg v OBug QacWmDBFH Ong %3d%3d 2/4
7/23/2021
Florida Building Code Online
Building Code, Including the High Velocity Hurricane Zone, and
Verified By: National Accreditation &Management Institute
where pressure requirements do not exceed the design pressures
Created by Independent Third Party:
listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system
Evaluation Reports
is NOT required. See DWG-MA-FL0172 for anchor details and water
FL22378 R7 AE 514008B.pdf
performance where required,
FL22378 R7 AE 514012B.pdf
Created by Independent Third Party: Yes
22378.7
Stommguard Fiberglass Side -Hinged Door
6'-8" Impact Glazed O/S Double Door w/ or w/o Sidelites
Unit
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22378 R7 C CAC NI007077,09-R4.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
12/31/2025
Design Pressure: +55/-55
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22378 R7 II FL0172 pdf
Building Code, including the H(gh Velocity Hurricane Zone, and
Verified By: National Accreditation &Management Institute
where pressure requirements do not exceed the design pressures
Created by Independent Third Party:
listed. 12'-0" x 6'-8" max nominal s(ze. Hurcicane protective system
Evaluation Reports
is NOT required. See DWG-MA-FL0172 for anchor details and water
FL22378 R7 AE 5140088.pdf
performance where required.
FL22378 R7 AE 514o128.pdf
Created by Independent Third Party; Yes
22378.8
Stormguard Fiberglass Side -Hinged Door
8'-0" Opaque I/S Single Door
Unit
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22378 R7 C CAC NI007077.08-R2.pd1:
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
12/31/2025
Design Pressure: +60/-65
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22378 R7 II FL0171.pdf
Building Code, including the High Velocity Hurricane Zone, and
Verified ey: National Accreditation &Management Institute
where pressure requirements do not exceed the design pressures
Created by Independent Third Party;
listed. 3'-0" x 8'-0" max nominal size. Hurricane protective system
Evaluation Reports
is NOT required. See DWG-MA-FL0171 for anchor details and water
FL22378 R7 AE 514009B.pdf
perfommance where required.
FL22378 R7 AE 514013B.pdf
Created by Independent Third Party: Yes
Z2378,9
Stormguard Fiberglass Side -Hinged Door
8'-0" Opaque O/S Single Door
Unit
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22378 R7 C CAC NI007077.08-R2.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
12/31/2025
Design Pressure: +60/-60
Installation Instructions
Other: Evaluated for use In locations adhering to the Florida
FL22378 R7 II FL0171.pdf
Building Code, including the High Velocity Hurricane Zone, and
Verified By: National Accreditation &Management Institute
where pressure requirements do not exceed the design pressures
Created 6y Independent Third Party:
listed. 3'-0" x 8'-0" max nominal size. Hurricane protective system
Evaluation Reports
is NOT required. See DWG-MA-FL0171 for anchor details and water
FL22378 R7 AE 514009B.pdf
perfommance where required.
FL22378 R7 AE 5140138.pdf
Created by Independent Third Party: Yes
22378.10
Stommguard Fiberglass Side -Hinged Door
8'-0" Opaque I/S Single or Double Door w/ or w/o Sidelites
Unit
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22378 R7 C CAC NI007077 08-R2 pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
12/31/2025
Design Pressure: +50.0/-50.5
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22378 R7 II FL0171.pdf
Building Code, Including the High Velocity Hurricane Zone, and
Verified By: National Accreditation &Management Institute
where pressure requirements do not exceed the design pressures
Created by Independent Third Party:
listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system
Evaluation Reports
is NOT required. See DWG-MA-FL0171 for anchor details and water
FL22378 R7 AE 514007B.�df
perfommance where required.
FL22378 R7 AE 5140118.pdf
Created by Independent Third Party: Yes
22378.11
Stommguard Fiberglass Side -Hinged Door
8'-0" Opaque O/S Single or Double Door w/ or w/o Sidelites
Unit
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22378 R7 C CAC NI007077 08-R2 pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
12/31/2025
Design Pressure: +55.0/-50.5
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22378 R7 II FL0171.pdf
Building Code, including the High Velocity Hurricane Zone, and
Verified By; National Accreditation &Management Institute
where pressure requirements do not exceed the design pressures
Created by Independent Third Party:
listed. 12'-0" x 8'-0" max norrfnal size. Hurricane protective system
Evaluation Reports
is NOT required. See DWG-MA-FL0171 for anchor details and water
FL22378 R7 AE 5140078.pdf
performance where required.
FL22378 R7 AE 5140116.pdf
Created by Independent Third Party; Yes
22378.12
Stormguard Fiberglass Side -Hinged Door
8'-0" Impact Glazed I/S Single or Double Door w/ or w/o Sidelites
Unit
https:/Mn�wvfloridabuilding.org/pr/pr_app dtl.asp�C?param=wGEVXQwtDgs3M6m9%2fK8XPIOX7�28WDo03rKdgwOBugQacWmDBFHOng%3d%3d 3l4
7/23/2021
Florida Building Code Online
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +43/-47
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design pressures
listed. 12'-0" x 8'-0" max norrfnal size. Hurricane protective system
is NOT required. See DWG-MA-FL0173 for anchor details and water
performance where required.
22378.13 Stommguard Fiberglass Side -Hinged Door
Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +47/-45
Other: Evaluated for use in locations adhering tD the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do not exceed the design pressures
listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system
is NOT required. See DWG-MA-FL0173 for anchor details and water
performance where required.
Certification Agency Certificate
FL22378 R7 C CAC NI007077.04-R7.pdf
Quality Assurance Contract Expiration Date
12/31/2025
Installation Instructions
FL22378 R7 II FL0173.pdf
Verified By: National Accreditation &Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22378 R7 AE 514007B
FL22378 R7 AE 514011B.pdf
Created by Independent Third Party; Yes
8'-0" Impact Glazed O/S Single or Double Door w/ or w/o Sidelites
Certification Agency Certificate
FL22378 R7 C CAC NI007077.04-R7.pdf
Quality Assurance Contract Expiration Date
12/31/2025
Installation Instructions
FL22378 R7 II FL0173.pdf
Verified By; National Accreditation &Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22378 R7 AE 514007E pdf
FL22378 R7 AE 514011B.pdf
Created by Independent Third Party: Yes
back Pvtytat
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Cop�ght 2007-2013 State of Florida.:: rivacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not vrant your a -mall address released In response to apublic-records request, do not send
electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to
Section 456,275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department vAth an email address If
they have one. The emalls provided may be used for official communication with the Ilcensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department vAth an email address wfiich can be made available to the public. To determine If you are a Ilcensee
underChapter455, F.S., please click here .
SC CtII"li}'1lt1TRICS`
https:/h�wrw.floridabuildi ng .org/pr/pr_app_dtl.asp>Clparam=wGEVXQwtDq s3M6m9%2iK8XPIOX7J28WDo03rKdg wOBug QacWmD BFH Ong %3d%3d 4/4
NOTICE OF PRODUCT CERTIFICATION
Company: Masonite International Corporation Certification No.:
1955 Powis Road Certification Date:
West Chicago, IL 60185 Expiration Date:
Revision Date:
NI007077.07-R3
05/22/2017
12/31/2025
07/27/2020
Product: Fiberglass Impact Rated Opaque Inswing or Outswing Door w/ and w/o Impact Rated Sidelites
ti (w/Wood Frame or Worldwide Composite Frame' unless noted)
Specification: TAS 201/202/203-94/ASTM E330-02
The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification
label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within
NAMI's Certified Product Listing=- at www.Namicertification.com. NAMI's Certification Program is accredited by The American National Standards Institute (ANSI).
Inswing
Glazed
Structural
Water
Missile
Test Report Number
Configuration
or
or
Maximum
Design
Test
Impact
Drawing Number &
Outswing
Opaque
Size
Pressure
Pressure
Rated
Comments
X
FS
Opaque
3'0" x 6'8"
+60/-65
0 psf
Yes
NCTL-210-3102-1/ATLNC 0129.02-15/ATLNC 1012A1-16
Single
Maximum Panel Size: 3'0" x 6'8"
Anchor Details-MA-FL0170-07/W-1807
X
O/S
Opaque
3'0" x 6'8"
+60/-60
3.75 psf/ 6.0 psf
Yes
NCTL-210-3102-1/ATLNC 0129.02-15/ATLNC 1012.01-16
Single
10.5 psf'`/9.0 psf a
Maximum Panel Size: 3'0" x 6'8"
7.5 psf s
Anchor Details-MA-FL0170-07/W-1807/W-1835/ W-1860
XX
FS
Opaque
6'0" x 6'8"
+501-50.5
0 psf
Yes
NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16
Double
Maximum Panel Size: 3'0" x 6'8"
Anchor Details-MA-FL0170-07/W-1807
XX
O/S
Opaque
6'0" x 6'8"
+55/-50.5
3.75 psf/ 6.0 psf
Yes
NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16
Double
8.25 psf'-/8.25 psf a
Maximum Panel Size: 3'0" x 6'8"
Anchor Details-MA-FL0170-07/W-1807/W-1835
XO/OX
FS
Opaque Door
6'0" x 6'8"
+50.51-50.5
0 psf
Door -Yes
NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16
Single w/Sidelite
Glazed Sidelite
Sidelite-Yes
Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8"
Anchor Details-MA-FL0170-07/W-1807
XO/OX
O/S
Opaque Door
6'0" x 6'8"
+551-50.5
3.75 psf/ 6.0 psf'
Door -Yes
NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16
Single w/Sidelite
Glazed Sidelite
8.25 psf'-/9.0 psf°
Sidelite-Yes
Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8"
Anchor Details-MA-FL0170-07/W-1807/W-1835
OXO
FS
Opaque Door
910" x 6'8"
+50.51-50.5
0 psf
Door -Yes
NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16
Single w/Sidelites
Glazed Sidelite
Sidelite-Yes
Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8"
Anchor Details-MA-FL0170-07/W-1807
OXO
O/S
Opaque Door
9'0" x 6'8"
+551-50.5
3.75 psf/ 6.0 psf'
Door -Yes
NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16
Single w/Sidelites
Glazed Sidelite
8.25 psf 2/9.0 psf 4
Sidelite-Yes
Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8"
Anchor Details-MA-FL0170-07/W-1807/W-1835
OXXO
FS
Opaque Door
12'4" x 6'8"
+501-50.5
0 psf
Door -Yes
NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16
Double w/Sidelites
Glazed Sidelite
Sidelite-Yes
Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8"
Anchor Details-MA-FL0170-07/W-1807
OXXO
O/S
Opaque Door
12'4" x 6'8"
+551-50.5
3.75 psf/ 6.0 psf 1
Door -Yes
NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16
Double w/Sidelites
Glazed Sidelite
8.25 psf ''-/8 25 psf 4
Sidelite-Yes
Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8"
Anchor Details-MA-FL0170-07/W-1807/W-1835
1-Denotes 2rSeries Threshold Design 2 -Denotes High Dam Threshold Design 3-W-1815 4-Denotes Worldwide Pro T4 Threshold 5-Denotes HP Outswing Threshold
National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072
Tel: (804) 684-5124/Fax: (804) 684-5122
NAMI AUTHORIZED SIGNATURE:
L. Roberto Lomas P. E.
1432 Woodford Rd.
Lewisville, NC 27023
434-688-0609
Manufacturer: Masonite
Report #: 514008B
Date: 10/10/2017
Product: Double Door with and without sidelites 12'x6'8" (wood frame)
Scope:
This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the
product described herein. These calculations comply with requirements of the Florida Building Code 7th edition (2020).
Anchor capacity in shear condition:
Solid members w/ a w/out gap:
a. With threads present in shear plane
Fastener type: #10 wood screw (ND5 2018, TR12)
Nominal diameter: D: 0.190 in Gap: g: 0.0000 in
Root diameter: Dr: 0.152 in Moment arm: 0.0000 in
Minimum required penetration: p: 1.140 in
Side member: Douglas Fir -Larch (6=0.50)
Side member thickness: t,= 1.000 in
Side member dowel bearing strength: Fe, = 40650 psi
Side member dowel bearing length: I, = 1.000 in
Mode Im
qm = 636.5 Ibs/in
P = 725.61 Ibs
KC,= 2,400
Zm= 302lbs
Mode I,
qs = 884 Ibs/in
P = 884 Ibs
Ko = 2,400
Z,= 368lbs
Min. Design value: Z= 110 ibs
Duration Factor: Co = 1.6
Allowable Design Value (ZCD): Z1=
Mode II
A: 0.0007
B: 1.07
C:-427.674
P = 331 Ibs
Kb = 2,400
Z= 138 Ibs
175 Ibs/anchor
Screw bending yield strength:
175 Ibs/anchor
Screw bending yield strength:
FA
80000
psi
Mode IITm
A:
0.00096
B:
0.57
C:
-253.623
Ms =
46.8 in-Ibs
P =
297 Ibs
Kb =
2,400
Z=
124 Ibs
Fastener type; 1/4 ITW Tapcon Tobulated values
N.O.A. 16-1222.06
Substrate: Hollow block
Minimum embedment: 1.25 in
Actual edge distance: 2.50 in
Mode III,
A:
0.00107
C:
-267.699
Mm =
46.8 in-Ibs
P =
319 Ibs
Ko =
2,400
Z=
133 Ibs
edge
distance
spac(ng (in)
2.00
4.00
2.00
130
161
4.00
163
202
Actual C To C spacing: 3.00 in
Allowable Design Value: Zll= 155 Ibs/anchor (per interpolation when needed)
Fastener type: #10 Tek screw
Substrate: 18 GA, Steel
Tabulated design value: Z= 1266 Ibs
Safety factor: Fs= 4
Allowable Design Value (ZFs): Z'= 316 Ibs/anchor
Minimum anchor capacity: 155 Ibs/anchor
Note: Anchors with the least capacity is used for calculations to qualify anchors with higher capacity.
Anchor calculations, minimum required anchors
36.38 36.38
` Al Al
A2 YA2 79,25
i Al Al `
7Z75
mooll
37.50 / 36.38 36.38 37.50`
Al
Y
Y_
Y
147.75 ,
79.25
Design pressure: 60.0 psf
Zone
Area
x
Load
Ind.
Max.
O.C,
Anchor
Result
Cap,
(Ibs)
QtY
Load
(Ibs)
Al
2.3
138
N/A
N/A
155
1 1
138
OK
AZ
7.7
463
6.00
200
155
1 5
93
OK
A3
7.7
463
N/A
N/A
155
1 3
154
OK
Design pressure: 60.0 psf
Zone
Area
2
(ft)
Load
(Ibs)
Ind.
(in)
Max.
O.C.
(in)
Anchor
Result
Cap.
(Ibs)
QtY
Load
(Ibs)
Al
2A
146
N/A
N/A
155
1
146
OK
A2
7.9
473
6.00
21.00
155
5
95
OK
A3
7.8
468
N/A
N/A
155
4
117
OK
A4
1 2.3
1 138
N/A
N/A
155
1
138
1 OK
A5
1 7.7
1 463
N/A
N/A
155
3
154
OK
Mode IV
A: 0,00135
B: 0.000
C: -93.6
P = 263 Ibs
Ko = 2.400
Z= 110 Ibs
• • 0 • • • '�/
�:��� •��C+ E NSF•.A • ti `!
*� 0,4gsl
TATC OF • w
s 1 ORtDP G�
�ONAL,E��`
Luis R. Lomas P.E.
FL No.: 62514
9/2/2020
L. Roberto Lomas P. E.
1432 Woodford Rd.
Lewisville, NC 27023
434-688-0609
rllomas onlrlomaspe.com
Anchor Locations:
Double door
79.25
6.00 TYR 7 8.19 TYPI —
3.00 TYP.� �-+—
Manufacturer: Masonite
Report 514008B
Date: 10/10/2017
6.00
1 an
MAX
O.C.
6.00
ti�v .��Q E NS+�.q`p00e
51
A , TAT OF40
• �`�
•:,LQRt�P. L
iiFs►
CG �.
NAL,E��`�
Luis R. Lomas P.E.
FL No.: 62514
9/2/2020
L. Roberto Lomas P. E.
1432 Woodford Rd. Manufacturer: Masonite
Lewisville, NC 27023 Report #: 514008B
434-688-0609 Date: 10/10/20V
rilomas a(iirlomaspe.com
Double door with sidelites
-- - 18,75 T'P,
6.00 TYP. --. 6.00 TYP --- 18.19 TYP.
3,00 TYP
�._.. 6.00_._.
t
y 6,.
MAX
O.C.
1 _
79,25
6,00
�iy
���,•.�ENs ..(P
1 •
• TAT OF ,•w
NAL.,E����
Luis R. Lomas P.E.
FL No.: 62514
9/2/2020
L. Roberto Lomas P. E.
1432 W0001010 Rd.
Lewisville, NC 27023
434-688-0609
rllomaQ"o Ilomaspe.coI I
Manufacturer: Masonite
Report #: 5140088
Date: 10/1012017
Installation instructions:
1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS
WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2"
MINIMUM EDGE DISTANCE, LOCATE ANCHORS AS SHOWN BELOW,
2, FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2"
MINIMUM EDGE DISTANCE, LOCATE ANCHORS AS SHOWN BELOW,
3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE
INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE, LOCATE ANCHORS AS SHOWN BELOW,
4, ALL FASTENERS TO BE CORROSION RESISTANT,
5, INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S
INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH
STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI.
C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM.
D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063J5 FU=30KSI
.052" THICK MINIMUM
6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE
DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN,
7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE, FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY
OF THE ARCHITECT OR ENGINEER OF RECORD,
8, 1 X BUCK OVER MASONRY/CONCRETE IS OPTIONAL,
9. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" UNITS MUST BE ANCHORED THROUGH
FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER
STRUCTURAL SUBSTRATE MATERIAL,
10. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE, UNITS MAY BE ANCHORED THROUGH
FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS,
11. WHERE I BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE, SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE
ARCHITECT OR ENGINEER OF RECORD,
12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
4of4
Luis R. Lomas P.E.
FL No.: 62514
9/2/2020
L. Roberto Lomas P.E.
Mode I,
qs =
1900 Ibs/in
P =
1900 IDS
Ko =
2,400
Zs=
792lbs
1432 Woodford Rd.
Lewisville, NC 27023
434-688-0609
Manufacturer: Masonite
Report #: 514012B
Date: 10/10/2017
Product: Double Door with and without sidelites 12'x6'8" (composite
frame)
Scope:
This analysis provides calculations, quantities, and
spacing requirements for installing product to substrate, and
it applies
only to the
product described herein. These calculations comply with
requirements of the
Florida Building Code 7th edition
(2020).
Anchor capacity in shear condition:
Solid members w/ S w/out gap:
a. With threads present In shear plane
Fastener type: #10 wood
screw
(NDS 20180 TR12)
Nominal diameter: D:
0.190
in
Gap:
g:
0,0000
in
Root diameter: Dr:
0.152
in
Moment arm:
0.0000
in
Minimum required penetration: p:
1.140
in
Screw bending yield strength:
Fyb =
80,000
psi
Side member: PVC
Main member: Spruce -Pine -Fir
(G=0.42)
Side member thickness: t,=
1.000
in
Main member thickness:
tm=
1.500
in
Side member dowel bearing strength: Fes =
100000
psi
Main member dowel bearing strength:
Fm =
30350
psi
Side member dowel bearing length: Is =
1.000
In
Main member dowel bearing length:
Im =
1.140
in
Mode Im
qm = 636.5 Ibs/in
P = 725.61 Ibs
Kt) = 2.400
Zm= 302lbs
Mode IIIm
Mode III,
A: 0.00092
C:-521.824
Mm = 46.8 in-Ibs
P = 529 Ibs
Min. Design value: Z= 125 Ibs Z= 212 Ibs Kb = 2.400 Kb = 2,400 KD = 2,400
Duration Factor: Co = 1.6 Z= 135 Ibs Z= 221 Ibs Z= 125 Ibs
Allowable Design Value (ZCo); Z'= 199 Ibs/anchor
Fastener Type: 1/4 ITW Topcon Tabulated values
N.0.A.16-1222,06
Substrate: Hollow block
A:
0.0005
B:
1.07
C:
-681.799
P =
510 Ibs
Kt, =
2.400
A:
0.00066
B:
0.57
C:
-253.623
Ms =
46.8 in-Ibs
P =
324 Ibs
edge
distance
spacing (in)
2.00
4.00
2.00
130
161
4.00
163
202
Mode IV
A: 0.00105
B: 0,000
C: -93.6
P = 299 Ibs
Minimum embedment:
1.25
in
Actual edge distance:
2.50
in
Actual C To C spacing:
3.00
in
Allowable Design Value:
Z11=
155 Ibs/anchor
(per Interpolation when needed)
Fastener type:
#10
Self tapping screw
(Calculations per 2015 Aluminum Design Manual, section J.5.5)
Nominal screw diameter:
D:
0.190 in
Screw root area: A, 0.0151 inz
Actual edge distance:
de:
1.085 in
Screw shear ultimate strength: Fs� 54.0 ksi
Per table J3.2 of 2010 Steel Construction Manual 14th Edition
Side member
material:
Vinyl PVC
Main member material: 6063-T5 aluminum
Thickness:
t,
1.000 in
Thickness: t2 0.052 in
Ultimate tensile strength:
Ftu,
14 ksi
Ultimate tensile strength: Ft z 22 ksi
Nominal strength per bearing (side
member):
An = 2Dt,F,�,
Rnl = 5320 Ibs (Eq J.5-12)
Nominal strength per bearing (main
member):
Rn = 2Dt2F1 2
Rn2 = 435 Ibs (Eq J.5-12)
Nominal strength per
tilting:
An = 4.2(t23D)'/zFn2
Rn = 478 Ibs (Eq J.5-13)
Nominal screw shear
strength:
Rn = A,Fn/1.25
An = 654 Ibs (Eq J.5-14)
Safety
factor:
n= 3
Allowable shear and bearing capacity:
Pa
145 Ibs/anchor
Fastener type:
#10
Self tapping screw
(Calculations per AISI 5100-16 and AI5C 2017)
Nominal screw diameter:
D:
0,190 in
Screw shear ultimate strength: Fs 54.0 ksi
Screw root area:
A,
0.0151 in2
Per table J3.2 of 2010 Steel Construction Manual 14th Edition
Side member
material:
Vinyl PVC
Main member material: Metal framing
Thickness;
t
1000 in
Thickness: t 0CA` '-
, 2
Ultimate tensile strength: F,,, 14 ksi Ultimate tensile strength: Fez
Nominal strength per tilting: An = 4.2(tz3D)'/zF�z An = 1001 Ibs (Eq E4.3.1-I) \\` �' R , � a,►'//l
Nominal strength per bearing (side member): An = 2.7Dt1F2, AM = 7182 Ibs (Eq E4,3.1-2 and -4) �N * • • 0 A4 • 4�
Nominal strength per bearing (main member): An = 2.7Dt2F 2 Rn2 = 1280 Ibs (Eq E4,3.1-3 and -5) ` v •�\Cj E 2Y ty �
Nominal screw shear strength: An = A,F,�/1.25 An = 654 Ibs
Safety factor: c= 3 a. *4�TVAT
5 1
Allowable shear and bearing capacity: Ps 218 Ibs/anchor
Minimum
hors with the least capacity is used for calculations to qualify anchors with higher capacity.
0 F • ��
1
'%'`Fs 0 R k V G�7
9 ONA�WEO�\`�
Luis R. Lomas P.E.
FL No.: 62514
9/2/2020
L. Roberto Lomas P.E.
1432WoodlordRd. Manufacturer: Masonite
Lewisville, NC 27023 Report #: 514012B
434-688-0609 Date: 10/10/2017
rllOmas aAirlomaspe.com
Anchor calculations, minimum required anchors
36,38 36.38 Design pressure: 60.0 psf
\ Al X.\ Al _..�
Ay
YAz 79.25
Al Al
72,75
37.50 36.38 36.38 37.50
Al � A4 A4 Al
% I� I �I_�
/� /�
Al A4 A4 Al
147.75
Anchor Locations:
Double door
6.00 TYP...-
�s.zs
2of4
4
79.25
147.75
Anchor Locations:
Double door
6.00 TYP...-
�s.zs
2of4
4
79.25
Max.
Anchor
Design pressure; 60.0 psf
Zone
Area
2
(fi)
Load
(Ibs)
Ind.
(in)
Max.
O.C.
Anchor
Result
Cap.
Q
Load
(Ibs)
At
2.4
146
N/A
N/A
145
2
73
OK
A2
7.9
473
600
21,00
145
5
95
OK
A3
7.8
468
N/A
N/A
145
4
117
OK
A4
2.3
138
1 N/A
N/A
145
1
138
OK
A5
7.7
463
1 N/A
N/A
145
4
116
OK
36.38 ----_-_----•1Lµ-_-_----____ 36.38
6.00 TYPT.--------^-'------ 18.19 TYP.
3.00 YP. -
I
i
464TATE 0 F ; w
31ORt4P. �'�•;
ONAL,E���`�
Luis R. Lomas P.E.
FL No.: 62514
9/2/2020
L. Roberto Lomas P. E.
1432 Woodford Rd, Manufacturer: Masonite
Lewisville, NC 27023 Report #: 514012B
434-688-0609 Date: 10/1012017
rllornas 0(7, dornaspe,corn
Double door with sidelites
6.00
7YP.
-� ---,.
', 6.00
?YP
3.00 TYP
'_..... _600. _._.
79.25
J
•�� �',•o,\G E N S'�c'gCP
=*• 0 51 0
TAT 0 F
ORI ;0
ONAltill 1E\����
Luis R. Lomas P.E.
FL No.: 62514
9/2/2020
L. Roberto Lomas P. E.
1432 Woodrord Rd.
Lewisville, NC 27023
434-688-0609
rllomas()Irlomaspe,com
Manufacturer: Masonite
Report #: 514012B
Date: 10/10/2017
Installation instructions:
1.
FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS
WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2"
MINIMUM EDGE DISTANCE, LOCATE ANCHORS AS SHOWN BELOW,
2,
FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2"
MINIMUM EDGE DISTANCE, LOCATE ANCHORS AS SHOWN BELOW,
3,
FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE
INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE, LOCATE ANCHORS AS SHOWN BELOW,
4.
ALL FASTENERS TO BE CORROSION RESISTANT,
5,
INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S
INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH
STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI,
C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PS1 MINIMUM.
D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063J5 FU=30KSI
.052" THICK MINIMUM
6,
ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE
DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN,
7,
WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY
OF THE ARCHITECT OR ENGINEER OF RECORD,
8,
1 X BUCK OVER MASONRY/CONCRETE IS OPTIONAL,
9.
WHERE SHIM OR BUCK THICKNESS IS LESS THAN lA/2" UNITS MUST BE ANCHORED THROUGH
FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS,
ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER
STRUCTURAL SUBSTRATE MATERIAL,
10,
WHERE WOOD BUCK THICKNESS IS IA/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE, UNITS MAY BE ANCHORED THROUGH
FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS.
11.
WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE, SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE
ARCHITECT OR ENGINEER OF RECORD,
12.
BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
4of4
��o • TAT OF
w'
���•c�.s 'c� �
0 RI G�'\�.
NAL`E���`�
Luis R. Lomas P.E.
FL No.: 62514
9/2/2020
NA
1111 MASONITE.
STORMGUARD FIBERGLASS DOOR UNIT
6'-8" DOUBLE DOOR WITH /WITHOUT SIDELITES
GFN RA NOT S
1. EVALUATED FOR USE IN LOCATIONS ADHERING TO
THE FLORIDA BUILDING CODE AND WHERE PRESSURE
REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM
DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES,
DOES NOT EXCEED THE DESIGN PRESSURES LISTED.
2. THIS PRODUCT DOES NOT REQUIRE THE USE OF
A HURRICANE PROTECTIVE SYSTEM (SHUTTERS).
3. POLYURETHANE CORE FLAME SPREAD INDEX OF 50
AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84.
4. PLASTICS TESTING:
rFCT ncccaicTlnni ncc11-T-
SELF IGNITION TEMP
ASTM 01929
1 752 'F > 650 'F 1 842 'F > 650 'F
RATE OF BURNING
ASTM D635
0.56 IN MIN 1 1.28 IN/MIN
SMOKE DENSITY
ASTM D2843
53,49 170.27
TENSILE STRENGTH'
ASTM D638
3,27 DIFF 1 1.87 DIFF
5, PLASTICS TESTING OF WORLDWIDE COMPOSITE FRAME (WHERE USED):
TCCT hCC/DiDT!\n,• unr-nT
SELF IGNI11ON TEMP
ASTM D1929
j 779 "F > 650 "F
RATE OF BURNING
ASTM D635
0.0 IN/MIN
,SMOKE DENSITY
ASTM D2843
39.0%
TENSILE STRENGTH'
ASTM D638
3.67. DIFF
wmrr IIVL ItNDILt DIKENGIH AHLK WEATHERING
4500 HOURS XENON ARC METHOD 1
11 11 11 11�1
r
149" MAX. OVERALL FRAME WIDTH CCC
L.
27" MAX 36.375" MAX. O Q CO
�- D.L.O. -PANEL W/ASTRAGAL FRAME WIDTH z of J
O
U) O
Z
LU
r C/7
ms � w
�I g 0
01'
DOUBLE DOOR UNIT W `SIDELITES aj al
SINGLE DOOR UNIT W/SIDELITE�
STRUCTURAL
WHERE WATER INFILTRATION PERFORMANCE IS
DESIGN PRESSURE RATING
REQUIRED TO BE 157 OF DESIGN PRESSURE
CONFIG
MAX WIDTH
INSWING
ALL OUTSWING
INSWING
BUMPER 0 S , Z-SERIES OiS
HP OJS
T4 OJS
I HIGH DAM 0'S
X
37.5
+60.0 ! -65.0
+60.0 -6D.0
N?A
+25.D ,�' -25.0 1 +40.0 J -40.0
+50.0 -50.0
+60.0 ; -60.0
+60.D
XX
1 74
-5505
55.0ll- -50.5
?A
-25.0 1 +40.0 -40.0
N'A
-50.5OX
OrXO
++50.0
+55.-50.5
5.0 +40.0 -40.0
NIA
+55.0 J -50.5
OXO
112.5
+50.5 , -50.5
....
.+55.0
+./ -50.5
+55.0 ,'-50.5OXXO
1 149
+50.0 50.5
0 -50.5
N;A
25.0 -25.D +40.0 -40.0 !
NA
+55
+55.0 I-50.5.0/-50.5
TABLE OF CONTENTS
SHEET # I DESCRIPTION
1 ITYPICAL ELEVATIONS & GENERAL NOTES
2 IANCHORING LOCATIONS & DETAILS
3 JANCHORING LOCATIONS & DETAILS
AddeAmjoWM
cmf�ftmuoO��, d
RBYIBwBd By.
Ome:
Scue N.T.S.
DWG. BY: SINS
CNN. BY:
KURT BALTHAZOR DRWING NG:
FLORIDA P.E. DWG-MA-FL017D-
#56533
SHEEP _L OF 3
3"
SEE DE(Ali
C"
DETAIL "D"
SEE DETAIL
"E" �I
3»
= 6"
30
3 3
3"
—
3it
f—
I Ili
I�
I
II I�
6
1
3»
i
io
I
ii
0
w
Nf
r
D
\A
w
6^—
—
` 6" 3"
it SIC w
3"
3"
6"
M�A St
#10 x
#10x2-
#10 x
DEl-AIL "C"
io
0
.I N
o �
v
a¢ SEE DETAIL
v,
J
a
w I
w
6"
x 2„
f
10 x 1" DETAIL "E" ASTRAGAL
ATTACH ASTRAGAL RETAINER BOLT
I 0 x 1 " STRIKE PLATE TO FRAME
AS SHOWN.
-�
INSWING THRESHOLD BUMPER O/S THRESHOLD HP 01S THRESHOLD
T
Z-SERIES O/S THRESHOLD
1.75" �1.047"
HIGH DAM O/S THRESHOLD
=THRESHOL)
�EE DEiAIL
C"
6"
ASTRAGAL RETAINER BOLT HOLE
,�---MUST BE DRILLED THROUGH
THE THRESHOLD & INTO THE
STRUCTURE DEEP ENOUGH
FOR A 1.375" THROW
QETAIL "F" ASTRAGAL
,• MSNATED CLA55 ,- INSOUIFD C1A55 1w
0.124' NEAT SfREYCINFYEO .- OECCRARVE INSERT 0.124• HEAT S,RENC0IENED
0.080• SA'T2Y (NOA 20-C622Ai) (OPTIQVAI) o.nas• svux (Na zaouzo,) (oPTu2ru.)
0.,2{ NFI,T SIRENORIENED i+F—.0,2a• RyP. 0.124• NEAT STRENOMRENED— I'i--.0,24- TERP,
BENYL FGW, W METAL SPACM i/Y BITE BUTYL• FOAM. CB YET& SPACER + ,/Y am w w O,U m Q Z
arx eas ^�F oow aes ror Bas �" uav B¢s OATE_ 4/9/07
SCALE:
•.• 4 N.T.S.
iYPf A GLAZING D AiR �a DWG. BY: SWS
LTE NTF kAZJNG DETAIL crY,E. �:
IMPACT RATED GLASS IMPACT RATED 8L&U
ATTACHMENT DETAIL
1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED,
SIGNED AND SEALED BY ROBERTO LOADS, PE
(FLORIDA #62514) WITH THE LOWEST (LEAST)
FASTENER RATING FROM THE DIFFERENT FASTENERS
BEING CONSIDERED FOR USE. JAMB, HEAD, AND
THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE
#10 WOOD SCREWS, 1/4" TAPCONS, AND #10 TEK SCREWS.
A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH
ANCHOR LOCATION, TAPCON EDGE DISTANCE MIN 2-1/2 It
WOOD SCREW EDGE DISTANCE MIN 3/4. TEK SCREW EDGE
DISTANCE MIN 1/2"0
2. ANCHORING INTO STEEL STRUCTURE MUST BE SUFFICIENT TO
ACHIEVE 3 THREADS MINIMUM BEYOND STEEL INTERIOR SURFACE.
3, THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM
ANSI/AFBcPA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT
OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE
MINIMUM EMBEDMENT OF 1-1/4"1
4, WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO
TRANSFER LOADS TO STRUCTURE.
5. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS.
0
U
a SEE DET
n "D" SHT.
J
d
3"
3^
f 3;
!l
IL
II!
0
it
2
It
I
it
t B��---
K
I,
io
� I
II
II
II 11
_
11 li
6,
6"
3
3^f
6"
6"
0.25"
SHIM
1.25"
MIN
TYPICAL MASONRY
ANCHOR INSTALLATION
1MIN" i
- — _ 0.25"
SHI
CL
TYPICAL WOOD BUCK
ANCHOR INSTALLATION
1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND
SERIES 980 GRADE 1 DEADLOCK HARDWARE TO 8E INSTALLED
AT 5-1/2" CENTERLINE.
2. 4" X 4" FULL MORTISE BUTT HINGES,
Mom"
SHIM
1X BUCK MASONRY
ANCHOR INSTALLATION
10
1"X1/2" CORRUGATED #10X2" WOOD SCREW
3" FROM EACH END 6' FROM EACH END
AND 7" OC AND 12" OC
ALATEX
CAULK
ACRYLIC
CAULK CL
f
COMBINATION WOOD COMBINATION WOOD
MULLION (BOXED) MULLION (BOXED)
WOOD SCREWS"
EACH END
INTEGRAL WOOD
MULLION (CHS)
(WO6DDSCREWS"
EACH END
ei
INTEGRAL WW
MULLION (CHS)
saw: N.T.S.
Dwc_ er: SWS
cwc. er:
DRAN9NG NO.:
DWG—MA-FL0170,
sNEEr 3 OF 3