HomeMy WebLinkAboutcompactionArdamanSoll Density - Nuclear
& Associates, Inc. Gauge
Permit # 2105-0074
Port St. Lucie Branch
Report Date: 02/01 /2022
Florida Registration No. 5950
460 NW Concourse Place, unit 1
Test Method: ASTM D6938
Port St. Lucie, Fl- 34986
Phone: 772-878-0072
Client: Project:
Renar Development Corp. 113-15-66-5434B
3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots
Stuart, FL 34996 Fort Pierce
Fort Pierce, FL
Test Results
Maximum
In Place
In Place
Optimum
Dry
In Place
Dry
Wet
Probe
Retest
Soil
Moisture
Density (pcf)
Moisture
Density
Density
Depth
Percent
Min Comp.
Test #
Of
Test Date
Proctor ID
Method
Classification
%
%
pcf)
pcf)
in
Compaction
(%)
Remark
552
01/28/22
22-013
A
9.5
120.5
8.4
118.6
128.6
12
98
95
Pass
Modified
553
01/28/22
22-013
A
9.5
120.5
8.3
117.5
127.3
12
98
95
Pass
(Modified)
554
01/28/22
22-013
A
--
9.5
120.5
7.5
115.0
123.E
12
95
95
Pass
(Modified)
555
01/28/22
22-013
A
--
9.5
120.5
8.1
113.9
123.1
12
95
95
Pass
(Modified)
Test
Information
Gauge
Test #
Test Location
Elevation
Reference
Make / Model / SN / Calibrated
Field Technician
552
House Pad - Pad Fill: House Pad. Lot# 88 at 9771 Palm Breezes Drive. North Footing
1.0
Top of Footing
CPN / MC-3 / M340507396 /
Tech, Port St. Lucie
553
House Pad - Pad Fill: House Pad. Lot# 88 at 9771 Palm Breezes Drive. East Portion
-1.0
Top of Footing
CPN / MC-3 / M3406 7396 /
Tech, Port St. Lucie
of Pad
554
House Pad - Pad Fill: House Pad. Lot# 88 at 9771 Palm Breezes Drive. South Footing
1.0
Top of Footing
CPN / MC-3 / M340507396 /
Tech, Port St. Lucie
555
House Pad - Pad Fill: House Pad. Lot# 88 at 9771 Palm Breezes Drive. West Portion
1.0
Top of Footing
CPN / MC-3 / M340507396 /
Tech, Port St. Lucie
of Pad
Remarks
Comments
Pass: Density Pass
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
1"Backscatter".
Gauge calibration data on file with the testing agency.
This item has been digitally signed and sealed by Jason
Manning on Feb 02, 2022 using a Digital Signature.
Printed copies of this document are not considered signed
and sealed and the SHA authentication code must be
verified on any electronic copies.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 1
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED
PENDING OUR WRITTEN APPROVAL.