HomeMy WebLinkAboutProduct Evaluation ReportBUILDING DROPS
A Perfect Solution in Every Drop!
Certificate of Authorization: 29578
of
JELD-WEN, inc.
Siteline Clad Double Hung Window
Impact Rated
for
Florida Product Approval
Current Florida Building Code
Method:
Category:
Sub — Category:
Product:
Material:
Product Dimensions:
398 E Dania Beach Blvd.
Suite 338
Dania Beach, FL 33004
954.399.8478 PH
954.744.4738 FX
contact@buildingdrops.com
1— A (Certificate Method)
Windows
Double Hung
Siteline Clad Double Hung Window
Aluminum Clad Wood
45" x 80"
Prepared For:
JELD-WEN, inc.
3737 Lakeport Blvd.
Klamath Fails, OR 97601
Prepared by:
Hermes F. Norero, P.E.
Florida Professional Engineer # 73778
Date: 08/03/2020
Contents:
Evaluation Report Pages 1— 3
Digitally signed by Hermes F Norero
Reason: I am approving this document
Date: 2020.08.26 00:16:14-04'00'
7a A' OF
0
c�
O ```,
I 'lilt
114,111111
Hermes F. Norero, P.E.
Florida P.E. No. 73778
BUILDING DROPS
A Perfect Solution in Every Drop
Certificate of Authorization: 29578
Manufacturer:
Product Category:
Product Sub -Category:
Compliance Method:
Product Name:
JELD-WEN, Inc.
Windows
Double Hung
State Product Approval Method (1)(a)
Siteline Clad Double Hung Window
(Impact Rated)
Date: 08/03/2020
Report No: 4205
Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for JELD-WEN, Inc.
based on Method 1a of the State of Florida Product Approval, Florida Department of Business & -
Professional Regulation - Florida Building Commission.
Limits of Use:
Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of
the product named herein.
This product has been evaluated for use in locations adhering to the current Florida Building Code.
See Installation Instructions SJW2015-125, signed and sealed by Hermes F. Norero, P.E. (FL # 73778)
for specific use parameters.
1. This product has been evaluated and is in compliance with the current Florida Building Code,
excluding the "High Velocity Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Chapter 16 of the current Florida Building Code and does not require an impact resistant
covering.
4. Site conditions that deviate from the details of drawing SJW2015-125 require further
engineering analysis by a Iicensed engineer or registered architect.
5. See Installation Instructions SJW2015-125 for size and design pressure limitations.
Hermes F. Norero, P.E.
Florida P.E. No. 73778
Page 2 of 3
BUILDING DROPS
A Perfect Solution in Every Dropl Date: 0
020 Report No:o: 42 4205
Certificate of Authorization: 29578
Certification Agency: The manufacturer has demonstrated compliance of products in accordance with the
Florida Building Code for manufacturing under a program audited by and approved
by Windows and Door Manufactures Association (FBC Organization #: CER1508).
Performance Standards: The product described herein has been tested per:
• AAMA/WDMA/CSA 101/I.S.2/A440-08/11
• ASTM E1886-13a
• ASTM E1996-14a
Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories, Inc.
(FBC Organization # TST1589)
Report: SJW2015-125, Report Date: 01/25/2016
Installation:
2. Certification Agency
Windows and Door Manufactures Association
(FBC Organization #CER1508)
Refer to Installation Instructions (SJW2015-125) for anchor types, spacing and more details of the
installation requirements.
Design Pressure:
Refer to Installation Instructions (SJW2015-125) for design pressure configurations.
Hermes F. Norero, P.E.
Florida P.E. No. 73778
Page 3 of 3
4" MAX.
8" O.C. MAX. FROM
THRU FIN �—} —r CORNERS
x
a
f
y
D
Z
3
d d d b d 1
WINDOW WIDTH
(45 3/8" MAX.)
8" O.C.
MAX. TYP
THRU FIN
TYPICAL ELEVATION WITH FASTENER SPACING
Installed Fastener Schedule:
1. Seal flange/frame to substrate.
2. Use #8 PH or greater fasteners through nail fin with sufficient length to penetrate a minimum of 1 1/2" into
the wood framing. For 2X wood frame substrate (min. S.G. = 0.42).
3. Host structure (wood buck, stud framing and opening) to be designed and anchored to properly transfer all
loads to the structure. The host structure is the responsibility of the architect or engineer of record for the
project of installation.
This schedule addresses only the fasteners required to anchor the
window to achieve the rated design pressure up to the size limitations
noted. It is not intended as a guide to the installation process and does
not address the sealing consideration that may arise in different wall
conditions. For the complete installation procedure, see the instructions
packaged with the door or go to www.jeld-wen.com.
Dow 899
'GLAZING DETAIL
FRAME SECTION (TYP)
VERTICAL SECTION
roveabsen.�x.ady ray�avamaP y
MIN.
EDGE
1 1/2- M
EMBEDMI
NAIL FIN INSTALLATION
FRAME JAMB SECTION (TYP)
HORIZONTAL SECTION
NOTE: mNk between NaNn9 flange & Wood opening.
Max Frame
DP Ratinq
Im act
45 3 8" x 80"
+50/-65
YES
General Notes:
1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of
the adopted International Building Code (IBC), the International Residential Code (IRC), the Florida
Building Code (FBC) and the industry standard requirement for the stated conditions.
2. Buck, framing and masonry by others and is responsibility of architect or engineer of record.
3. All glazing shall conform to ASTM E1300.
4. At minimum, glazing shall be 3.Omm annealed - 8.6mm airspace - 2.5mm annealed - 2.3mm PVB
Intedayer by Dupont - 2.5mm annealed insulating glass.
PROJECT ENGINEER: DATE.
-- 10/08/2015
DRAWN BY: SCALE:
D. Vezo NTS
CHECKED BY:
JELD WEN th F Lakeport Blvd
Klamath Falls, OR. 97601
Phone: (800)535-3936
DISCLAIMER: APPROVED
P R VEDStoBY: Siteline Clad Double Hung Impact Window
This drawing and its contents are confidential and are not to be P5RTLPROJ o�:
reproduced or copied in whole or in part or used or disclosed to others DU 1LE l9.
except as authorized by dELD-WEN Inc. IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG. No.: REV: SHEET
SJW2015-125
4" MAX.
16" O.C. MAX. FROM
THRU FRAME CORNERS
K
Q
f
2
2
O
z_
WINDOW WIDTH
1 6" O.C.
MAX. TYP
THRU
FRAME
(45 3/8" MAX.)
TYPICAL ELEVATION WITH FASTENER SPACING
Installed Fastener Schedule:
1. Seal flange/frame to substrate.
2. Use #8 PH or greater fasteners through frame with sufficient length to penetrate a minimum of 1 1/2" into
the wood framing. For 2X wood frame substrate (min. S.G. = 0.42).
3. Host structure (wood buck, stud framing and opening) to be designed and anchored to properly transfer all
loads to the structure. The host structure is the responsibility of the architect or engineer of record for the
project of installation.
This schedule addresses only the fasteners required to anchor the
window to achieve the rated design pressure up to the size limitations
noted. It is not intended as a guide to the installation process and does
not address the sealing consideration that may arise in different wall
conditions. For the complete installation procedure, see the instructions
packaged with the door or go to www.jeld-wen.com.
DISCLAIMER:
This drawing and its contents are confidential and are not to be
reproduced or copied in whole or in part or used or disclosed to others
except as authorized by JELD-WEN Inc.
Dow f'99
II
EME
JELBrWENKJamath
MIN. DISTAN
FROM EDGE:
THROUGH FRAME"
INSTALLATION
FRAME JAMB SECTION (TYP)
HORIZONTAL SECTION
45 3 8" x 80"
+50/-65
YES
Max Max Frame DP Rating Impact
General Notes:
1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of
the adopted International Building Code (IBC), the International Residential Code (IRC), the Florida
Building Code (FBC) and the industry standard requirement for the stated conditions.
2. Buck, framing and masonry by others and is responsibility of architect or engineer of record.
3. All glazing shall conform to ASTM E1300.
4. At minimum, glazing shall be 3.0mm annealed - 8.6mm airspace - 2.5mm annealed - 2.3mm PVB
Interiayer by Dupont - 2.5mm annealed insulating glass.
PROJECT ENGINEER:
DRAWN BY:
D. Vezo
CHECKED BY:
L. Molatore
APPROVED BY:
D. Stokes
PDT6P1203�9
IDENTIFIER No.
SJW2015-125
DATE:
10/08/2015
SCALE:
NTS
TITLE:
3737 Lakeport Blvd
Falls, OR. 97601
Phone: (800)535-3936
Siteline Clad Double Hung Impact Window
PLANT NAME AND LOCATION: I CAD DWG. No.: I REV: I SHEET
4" MAX.
16" O.C. MAX. FROM
THRU FRAME —t--� CORNERS
X
Q
b
it
D
Z_
3
I- WINDOW WIDTH
16" O.C.
MAX. TYP
THRU
FRAME
(45 3/8" MAX.)
TYPICAL ELEVATION WITH FASTENER SPACING
Installed Fastener Schedule:
1. Seal flange/frame to substrate.
2. Install masonry straps to wood frame using #8 corrosion resistant fasteners no more then 4" from each
comer and 16" o.c. along the jambs and head. Bend straps around buck and secure with #8 fastener thru
masonry strap into buck. Fasteners must be long enough to penetrate at least 1" into framing members.
3. Host structure (wood buck, stud framing and opening) to be designed and anchored to properly transfer all
loads to the structure. The host structure is the responsibility of the architect or engineer of record for the
project of installation.
This schedule addresses only the fasteners required to anchor the
window to achieve the rated design pressure up to the size limitations
noted. It is not intended as a guide to the installation process and does
not address the sealing consideration that may arise in different wall
conditions. For the complete installation procedure, see the instructions
packaged with the door or go to www.jeld-wen.com.
DISCLAIMER:
This drawing and its contents are confidential and are not to be
reproduced or copied in whole or in part or used or disclosed to others
except as authorized by JELDVEN Inc.
Min. Dfstanm Fmm
Edge:3/4'
o MASONRY
° BLOCK
a °
2 Min,
1 1/2- MIN. From
EMBEDMENT
1/4' MAX
SHIM SPACE
3.Omm
Gia. BRe
18.42mm
7.3mm
23mm
` Dow 899
GLAZING DETAIL
FRAME SECTION (TYP)
VERTICAL SECTION
NOTE: huh0. NA"N &N Opa4
MASONRY STRAP " ,
INSTALLATION
1 12- MIN.
FRAME JAMB SECTION (TYP)
HORIZONTAL SECTION
Max Frame
DP Rating
Impact
45 3 8" x 80"
+50/-65
YES
General Notes:
1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of
the adopted International Building Code (IBC), the International Residential Code (IRC), the Florida
Building Code (FBC) and the industry standard requirement for the stated conditions.
2. Buck, framing and masonry by others and is responsibility of architect or engineer of record.
3. All glazing shall conform to ASTM E1300.
4. At minimum, glazing shall be 3.0mm annealed - 8.6mm airspace - 2.5mm annealed - 2.3mm PVB
Intedayer by Dupont - 2.5mm annealed insulating glass.
PROJECT ENGINEER:
DRAWN BY:
D. Vezo
CHECKED BY:
L. Molatore
APPROVED BY:
D. Stokes
PP12039
6T�
IDENTIFIER No.
SJW2015-125
DATE:
10/08/2015
SCALE:
NTS
TITLE:
JELRWENI(larnathLakeport Blvd
Falls, OR. 97601
Phone: (800)535-3936
Siteline Clad Double Hung Impact Window