HomeMy WebLinkAboutRevisions OFFICE USE ONLY:.
DATE FILED:. PERMIT 4 .c�/00? 0
REVISION FEE: RECEIPT#
PLANNING & DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION viECoNfD
2300 VIRGINIA AVENUE
FORT PIERCE,FL 34982-5652 FEB p 12022
(772)462-1553 Aunty
' St.perml�tlR9
APPLICATION.FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS: i
DETAILED DESCRIPTION OF PROJECT
REVISIONS: C
�✓1 ( O
CONTRACTOR INFORMATION: FILE P
STATE of FL REG./CERT.#: ST. LUCIE CO CERT. #:
BUSINESS NAME:
QUALIFIERS NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME): FAX:
OWNER/BUILDER INFORMATION:
NAME: et-f
ADDRESS:
CITY: STATE: ZIP:
PHONE (DAYTIME: FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:. r�f S
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME): 2-7 3-- FAX:
SLCCC: 9123109
Revised 06/30/17
n.
FILE COPY
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation -.Residential Performance Method
Project Name: MW-168 Builder Name: GHO BUILDERS
.Street: 9406 PINEBARK CT. Permit Office: SLLucie County
City.State,Zip: FORT PIERCE,FL,34951 Permit Number:2,16 2., - 03�Z
Owner: Jurisdiction:
Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 10. Wall Typet2378.1 sqft.) Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Ext Insul,Exterior R=4.1 2068.30 ft'
b.Framer Wood,Adjacent R=11.0 309.78 ft'
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 3 d.N/A R= ft'
11.Ceiling Types(2674.8 sqft.) Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=40.0 2284.00 ft'
6. Conditioned floor area above grade(ft') 2284 b.Knee Wall(Vented) R=38.0 390.80 fl'
Conditioned floor area below grade(ft') 0 c.N/A R= ft,
7. Windows(441.2 sqft.) Description Area 12.Ducts R (t'
a.Sup:Attic,Ret:Attic,AH:Main 6 630
a. U-Factor: Dbl,U=0.62 441.15 ft'
SHGC: SHGC=0.26
b. U-Factor: N/A fN 13.Cooling systems kBlu/hr Efficiency
SHGC: a.Central Unit 46.5 SEER:16.00
c. U-Factor: N/A ft'
SHGC: 14.Heating systems kBtulhr Efficiency
Area Weighted Average Overhang Depth: 6.640 ft.
Area Weighted Average SHGC: 0.260 a.Electric Strip,Heat 34.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft, 15.Hot water systems
SHGC(AVG): NIA a.Electric Cap:50 gallons
9. Floor Types (2284.0 sqft.) Insulation Area EF:0.940
a.Slab-On-Grade Edge Insulation R=0.0 2284.00 ft' b. Conservation features
b.N/A R= ft' None
c.NIA R= ft' 16.Credits Pstal
Glass/Floor Area: 0.193 Total Proposed Modified Loads: 71.98 PASS
Total Baseline Loads: 73.48
I hereby certify that the plans and specifications covered by Review of the plans and O,THE Sr4
this calculation are in compliance with the Florida Energy specifications covered by this < 1�,��"` a°� O� n
Code. calculation indicates compliance
with the Florida Energy Code. uu„ " w„ O
PREPARED BY: _ Before construction is completed
R,
DATE: 0�T3d this building will be inspected for1 _G
compliance with Section 553.908
hereby
the Florida Energy Code.
with building,as designed, is,in compliance Florida Statutes. �COp�
-
OWNER/AGENT: BUILDING OFFICIAL: V
DATE: �( 2.D2� DATE: -
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
1/13/2022 11:12 AM 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 5
r
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: MW-168 Bedrooms: 3 Address Type: Street Address
Building Type: User Conditioned Area: 2284 Lot#
Owner Name: Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: GHO BUILDERS Rotate Angle: 0 Street: 9406 PINEBARK CT.
Permit Office: S_t.Lucle County Cross Ventilation: NO County: St.Lucie
Jurisdiction: Whole House Fan: No City,State,Zip: FORT PIERCE,
Family Type: Detached FL, 34951
New/Existing: New(From Plans)
Comment:
CLIMATE
/ Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Blockl 2284 23068.4
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InftIID Finished Cooled Heated
1 Main 2284 23068.4 Yes 4 3 1 Yes Yes Yes
- FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 241.1 ft 2284 ft' __._ 0 0 1
ROOF
/ Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. .(deg)
1 Hip Flat tile/slate 2554 ft' 0 R' Medium N 0.4 N 0.9 No 0 26.57
`/ ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 2284 ft' N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 40 Blown 2284 ft' 0.1 Wood
2 . Knee Wall(Vented) Main 38 Blown 390.8 ft' 0.1 Wood
1/13/2022 11:12 AM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
0
F . 1 N Exterior Concrete Block-Ext Insul Main 4.1 58 2 9 4 542.9 ft' 0 0 0.3 0
-2 NE Exterior Concrete Block-Ext Insul Main 4.1 8 9 11 4 99.2 ft' 0 0 0.3 0
_3 E Exterior Concrete Block-Ext Insul Main 4.1 55 7 9 4 518.8 ft' 0 0 0.3 0
_4 SE Exterior Concrete Block-Ext Insul Main 4.1 2 11 11 4 33.1 ft' 0 0 0.3 0
_5 S Exterior Concrete Block-Ext Insul Main 4.1 32 0 11 4 362.7 ft' 0 0 0.3 0
6 W Exterior Concrete Block-Ext Insul Main 4.1 54 10 9 4 511.8 ft' 0 0 0.3 0
7 Garage Frame-Wood Main 11 27 4 11 4 309.8 ft' 0 0.25 0.3 0
DOORS
# Ornt Door Type Space Storms U-Value Ft Width In Ft WidthArea
1 S Wood Main None .39 3 8 24 ft'
WINDOWS
Orientation shown is the entered.Proposed orientation.
/ Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 n 1 Metal Double(Clear) Yes 0.62 0.26 N 7.0 ft' 2 ft 0 in 1 ft 0 in None None
2 n 1 Metal Double(Clear) Yes 0.62 0.26 N 43.3 ft' 2 ft 0 in 1 ft 0 in None None
3 n 1 Metal Double(Clear) Yes 0.62 0.26 N 31.6 ft' 4 ft 0 in 2 ft 0 in None None
4 n 1 Metal Double(Clear) Yes 0.62 0.26 N 111.6 ft' 12 ft 0 in 2 ft 0 in None None
5 no 2 Metal Double(Clear) Yes 0.62 0.26 N 22.5 ft' 5 ft 0 in 2 ft 0 in None None
6 ne 2 Metal Double(Clear) Yes 0.62 0.26 N 18.7 It' 10 it 0 in 2 ft 0 in None None
7 e 3 Metal Double(Clear) Yes 0.62 0.26 N 11.8 ft' 2 ft 0 in 1 ft 0 In None None
8 e 3 Metal Double(Clear) Yes 0.62 0.26 N 7.0 ft' 2 ft 0 in 1 ft 0 in None None
9 e 3 Metal Double(Clear) Yes 0.62 0.26 N 21.3 ft' 15 ft 0 in 3 ft 0 in None None
10 se 4 Metal Double(Clear) Yes 0.62 0.26 N 14.0 ft' 2 ft 0 in 1 ft 0 in None None
11 s 5 Metal Double(Clear) Yes 0.62 0.26 N 8.0 ft' 8 ft 0 in 2 ft 0 in None None
12 s 5 Metal Double(Clear) Yes 0.62 0.26 N 15.0 ft' 2 ft 0 in 1 ft 0 in None None
13 s 5 Metal Double(Clear) Yes 0.62 0.26 N 48.0 it' 2 ft 0 in 1 ft 0 in None None
14 S 5 Metal Double(Clear) Yes 0.62 0.26 N 8.0 ft' 8 ft 0 in 4 ft 0 in None None
15 w 6 Metal Double(Clear) Yes 0.62 0.26 N 9.0 ft' 2 ft 0 in 1 ft 0 in None None
16 w 6 Metal Double(Clear) Yes 0.62 0.26 N 21.3 ft' 2 ft 0 in 1 ft 0 in None None
17 w 6 Metal Double(Clear) Yes 0.62 0.26 N 21.7 It' 2 ft 0 in 1 ft 0 in None None
18 W 6 Metal Double(Clear) Yes 0.62 0.26 N 21.3 ft' 15 it 0 in 2 ft 0 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 686 ft' 686 ft' 64 it 9.3 It 1
1/13/202211:12 AM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000449 2691.3 147.65 277.2 .1387 7
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Strip Heat/ None COP:1 34 kBtulhr 1 sys#1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Singl SEER:16 46.5 kBtu/hr cfm 0.7 1 sys#1
HOT WATER SYSTEM
# System Type SubTpe Location EF Cap Use SetPnt Conservation
1 Electric None Main 0.94 50 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft'
DUCTS
J —Supply— —Return— Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 630 ft= Attic 320 ft° Default Leakage Main (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Heating
[]Jan []Feb HX
Mar [ ]Apr I ]May rl Jun JXJ Jul [X]Augri
Sepp [ )Oct []Nov [1 Dec
Heatin EXl]Jan ExJ}Feb Mar I[X�]Apr [[ ]]Ma E ]]Jun Jul [[ )]Aug Sep [[x]1 Oct IIxJJ Nov [Ix])Dec
VentingJan Feb Mar Apr may Jun Jul Aug Se Oct X Nov Dec
1/13/202211:12 AM 7.0.00-FlaRes202O FBC 71h Edition(2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main
1/13/2022 11:12 AM 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index,the more efficient the home.
9406.PINEBARK CT., FORT PIERCE, FL, 34951
1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Ext Insul,Exterior R=4.1 2068.30 f'
b.Frame-Wood,Adjacent R=11.0 309.78 fl
3. Number of units,if multiple family 1 c.NIA R= ft--
4. Number of Bedrooms 3 d.NIA R= ft'
11.Ceiling Type and insulation level Insulation Area
5. Is this.a worst case? No a.Under Attic(Vented) R=40.0 2284.00 ft'
6. Conditioned floor area(W) 2284 b.Knee Wall(Vented) R=38:0 390.80 IF
7. Windows" c.NIA R= it,
Description Area 12.Ducts,location&insulation level R ft'
a. U-Factor: Dbl,U=0.62 441.15 ft' a.Sup:Attic,Ret:Attic,AH:-Main 6 630
SHGC: SHGC=0.26
b. U-Factor: NIA ft'
SHGC: 13.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A IF a.Central Unit 46.5 SEER:16.00
SHGC:
d. U-Factor: N/A ft' 14.Heating systems kBtu/hr .Efficiency
SHGC: a.Electric Strip Heat 34.0 COP:1.00
Area Weighted Average Overhang Depth: 6.640 ft.
Area Weighted Average SHGC: 0.260
8. D Skylights escri Description Area 15.Hot water systems
p Cap:50 gallons
a. U-Factor(AVG): N/A ft2 a.Electric EF:0.94
SHGC(AVG): N/A
b. Conservation features
9. Floor Types Insulation Area None
a.Slab-On-Grade Edge Insulation R=0.0 2284.00 fl' Credits(Performance method) Pslat
b.N/A R= fl'
c.N/A R= ft=
I certify that this home has complied with the Florida Energy Efficiency Code for Building 4 THE sTgr
Construction through the above energy saving features which will be installed or exceeded O
9 9Y 9 ( � � a � o
in this home before final inspection. Ot erwise,a new EPL Display Card will be completed :;<
based on installed Code compliant fea res.
Builder Signature: Date:
Address of New Home: iY�e'D�tY1�- C� , City/FLZip: p�eY(>° r�ycov�
3gg5I °"'`
`Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify'for energy efficient
mortgage(EEM)incentives if you obtain a Florida Energy Rating. For information about-the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/13/2022 11:12 AM 7.0.00-FlaRes202O FBC 71h Edition(2020) Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation, 7th Edition (2020)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 9406 PINEBARK CT, Permit Number:
FORT PIERCE,FL,34951
MANDATORY REQUIREMENTS-See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level(EPL)display card(Mandatory).The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
(Section 553.9085,Florida Statutes)requires the EPL display card to be Included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains Information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD.
SECTION R402 BUILDING THERMAL ENVELOPE
❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
II
R402.4.1 Building thermal envelopeThe building thermal envelope shall comply with Sections R402.4.1.1 and
R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
❑ R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required
by the code official,an approved third party shall Inspect all components and verify compliance.
❑ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either
individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or
an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures.
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures.
3.Interior doors,if installed at the time of the test,.shall be open.
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5.Heating and cooling systems,if installed at the time of the test,shall be turned off.
6.Supply and return registers,if Installed at the time of the test,shall be fully open.
❑ R402A.2 Fireplaces. New wood-buming fireplaces shall have light-fitting flue dampers or doors,and outdoor combustion air.Where
using tight-fitting doors on factory-built fireplaces listed and labeled In accordance with UL 127,the doors shall be tested and listed for the
fireplace.Where using tight-filling doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907.
❑ R402A.3 Fenestration air leakage. Windows,skylights and sliding glass doors shall have an air Infiltration rate of no more than 0.3 cfm
per square foot(1.5 Lls/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,Independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
1/13/2022 11:12 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
❑R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to
open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room,isolated from Inside the thermal envelope.Such rooms shall be sealed and insulated In accordance with the envelope requirements
of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be
fully gasketed and any water lines and ducts in the room Insulated in accordance with Section R403.The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both Intake and exhaust pipes installed continuous to the outside,
2. Fireplaces and stoves complying with Section R402A.2 and Section R1006 of the Florida Building Code,Residential.
❑R402.4.5 Recessed lighting. Recessed luminaires installed In the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested In accordance with ASTIVI E283 at a 1,57 psi(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 Controls.
❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electdc-resistance heal shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct lightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or
(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(I),Florida Statutes,to be"substantially leak free"in
accordance with Section R403.3.3.
❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
❑ R403.3.3 Duct testing(Mandatory).Ducts shall be pressure tested to determine air leakage by one of the following methods:
1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 Inch w.g.(25 Pa)across the system,
including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise
sealed during the test.
2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire
system,Including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.Duct leakage testing Is required for Section
R405 compliance where credit is taken for leakage,and a duct air leakage On to the outside of less than 0.080(where On=
duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals)is indicated in the
compliance report for the proposed design.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
❑R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or.plenums.
❑R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F.(41°C)
or below 55°F(13°C)shall be insulated to a minimum of R-3.
❑ R403A.1 Protection of piping Insulation. Piping insulation exposed to weather shall be protected from damage,Including that
caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause
degradation of the material.Adhesive tape shall not be permitted.
❑ R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). If heated water circulation systems are
Installed,they shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with
Section R403.5.1.2.Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall
❑ be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited.Controls for
circulating hot water system pumps shall start the pump based on the Identification of a demand for hot water within the occupancy.The
controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no
demand for hot water.
❑ R403.5.1.2 Heat trace systems.Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall
automatically adjust the energy Input to the heat tracing to maintain the desired water temperature in the piping in accordance with the
times when heated water is used in the occupancy.
1/13/2022 11:12 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 5
i
MANDATORY REQUIREMENTS - (Continued) .
❑ R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both.the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'Y2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies(Mandatory).
❑ R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature
setting range shall be from 100°F to 140°F(38°C to 60'C).
❑ R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of
combustion types of service water-heating systems to be turned off.
❑ R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water-heating category.Solar water healers shall meet the criteria of Section R403.5.6.2.1.
❑ R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors In Installed solar
water-heating systems should meet the following criteria:
1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be Installed at an orientation within 45 degrees of true south.
❑ R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation
Including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.,
❑ R403.6.1 Whole-house mechanical ventilation system fan efficacy.When installed to function as a whole-house mechanical
ventilation system,fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole-house mechanical
ventilation,the air handler shall be powered by an electronically commutated motor.
❑ R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable
Indoor Air uality,shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawispaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10
otherwise.
R403.7 Heating and cooling equipment.
R403.7.1 Equipment sizing(Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based
❑ on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation
methodologies,based on building loads for the directional orientation of the building.The manufacturer and model number of the
outdoor and Indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design
conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other
factors that affect equipment sizing.System sizing calculations shall not include loads created by local Intermittent mechanical
ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have
an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is
installed.
TABLE R403.6.1
WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMU
(CFM) (CFM/WATT) (CFM)
HRV or ERV Any 1.2 cfm/watt Any
Range hoods Any 2.8 cfm/watt Any
Incline fan Any 2.8 cfm/watt Any
Bathroom,utility room 10 1 A cfm/watt <90
Bathroom,utility room 90 2.8 cfm/watt Any
For SI:1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916
1113/202211:12 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section R403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's
expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded
performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed In an unconditioned space.
Exceptions:
1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by aFlorida-registered engineer,In attached single-and multiple-family units,the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 limes greater than the design cooling load even if
the design heating load Is 1.15 times greater than the design cooling load.
R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
❑ C403 and C404 of the Florida Building Code,Energy Conservation—Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and ice system controls(Mandatory)Snow-and ice-melting systems,supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature Is above 50°F(10°C),and no
precipitation Is failing and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C).
R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an
Integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation
of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the
power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches.Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
1/131202211:12 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 5
❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered
energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required.
❑ R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April 16,2013.when tested in accordance with ANSI Z 21.56.Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
❑ R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHR11180,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
❑ R403.11 Portable spas(Mandatory).The energy consumption of electric-powered portable spas shall be controlled by the
requirements of APSP-14.
R403.13 Dehumidifiers(Mandatory If installed,a dehumidifier shall conform to the following requirements:
1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters!kWh if the total dehumidifier capacity for the house
is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day.
2. The dehumidifier shall be controlled by a sensor that is installed In a location where it Is exposed to mixed house air.
3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2.
4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code,Residential.
❑ R403.13.1 Ducted dehumidifiers. Ducled dehumidifiers shall,in addition to conforming to the requirements of Section R403.13,
conform to the following requirements:
1. If a ducted dehumidifier Is configured with return and supply ducts both connected Into the supply side of the cooling system,a backdraft
damper shall be Installed in the supply air duct between the dehumidifier inlet and outlet duct.
2. If a ducted dehumidifier Is configured with only Its supply duct connected Into the supply side of the central healing and cooling system,
a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct.
3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the
central cooling evaporator coil.
4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment(Mandatory). Not less than 90 percent of the lamps In permanently installed luminaires shall have an
efficacy of at least 45 lumens-per-watt or shall utilize lamps with an efficacy of not less than 65 lumens-per-watt.
R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
1/13/2022 11:12 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 5 of 5
i
2020-AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1 a
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: MW-168 Builder Name: GHO BUILDERS
Street: 9406 PINEBARK CT. Permit Office: St.Lucie County
City,State,Zip: FORT PIERCE,FL,34951 Permit Number: V
Owner. Jurisdiction: _
Design Location: FL,Fort Pierce v
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
Ceilinglattic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity
sealed. with a material having a thermal resistance of R-3
Knee walls shall be sealed, per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/door jambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be Insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity Insulation
and cantilevered shall be permitted to be in contact with the top side
flcom) of sheathing,or continuous Insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls.
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities Installation
shall be filled by insulation that on
Installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spa s.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
Showeritub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on exterior wall tubs shall separate them from the showers and tubs. be insulated.
Electricallphone box or The air barrier shall be installed behind electrical or communication
exteriorwalls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub-floor,wall covering or
Concealed When required to be sealed,concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. n addition,inspection of og walls shall be n accor ante 59 0.proves ons of I CC-400.
Ill 312022 11:12 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2020 Florida Building Code, Energy Conservation, 7th Edition
Jurisdiction: Permit#:
Job.Information
Builder: GHO BUILDERS Community: Lot: NA
Address: 9406 PINEBARK CT.
City: FORT PIERCE State: FL Zip: 34951
Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method
O PRESCRIPTIVE METHOD=The building or dwelling unit.shall be tested and verified ad having an air leakage rate of not exceeding 7 air
changes per hour at a pressure of 0.2 inch w.g.(50 Pascals)in Climate Zones 1 and.2.
O PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an,air leakage rate of not.exceeding
the-selected ACH(50)value,as-shown on Form R4054020(Performance)or R406-2020(ERI),section labeled as infiltration,subsection ACH50.
ACH(50):•spec1Bed on.Form R405.2020�Energy:Calc(Perfo►mance)orR406.2020(ERQ.-, 7.000
x 60 + 23068 — Method for calculating building volume:
CFM(50) Building Volume ACH(50) O Retrieved from architectural plans
PASS •Code software calculated
When ACH(50)Is less than 3,Mechanical Ventilation installation O Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSIIRESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals)
Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth In Section
489.105(3)(0.(g),or(1)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration
control measures.
2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended Infiltration control
measures.
3.Interior doors,if installed at the time of the test,shall be open.
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
S.Healing and cooling systems.If installed at the time of the test,shall be turned off.
6.Supply and return registers,if installed at the time of the test,shall be fully open.
Testing Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification#: Issuing Authority:
1/131202211:12:43 AM EnergyGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 1 of 1
Load Short Form J°�`
wright�oft
f�+ b Data: Jan 11,zozi
Entire House By.
•
For: MW-168
9406 PINEBARK CT.,FORT PIERCE.FL 34951
i g • on
Htg Clg Infiltration
Outside db(`F) 43 90 Method Simplified
Inside db(°F) 70 72 Construction quality Tight
Design TD('F► 27 18 Fireplaces 0
Daily range - L
Inside humidity(%) 30 50
Moisture difference(gri1b) 0 668
HEATING EQUIPMENT COOLING EQUIPMENT
Make Make Lennox
Trade Trade LENNOX
Model Cond ML14XC1-047-230A"
AHRI ref Coil CBA27UHE-048-230'++TDR
AHRI ref 10259428
Efficiency 100 EFF Efficiency 13.0 EER.16 SEER
Heating input 10.0 kW Sensible cooling 32900 Btuh
Heating output 34035 Stuh Latent cooling 14100 Btuh
Temperature rise 20 'F Total cooling 47000 Bluh
Actual air flow 1567 cfm Actual air floty 1567 cfm
Air flow factor 0.048 dmrBtuh Airflow-factor 0.048 cfm/Btuh
Static pressure 0 in H2O Stalfcpressure 0 in H2O
Space thermostat Load sensible heat ratio 0.74
ROOM NAME Area Htg load Cig load HtgAVF CIgAVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
MASTER SUITE 385 5759 5259 277 251
HER WIC 45 39 230 2 11
HIS WIC 86 1214. 724 58 35
GREAT ROOM 435 5282 5631 254 269
DINING 159 2946 2680 142 128
FOYER 57 1254 995 60 48
NOOK 95 2522 2604 121 124
KIT 210 178 1670 9 80
BED 3 1.47 1562 2862 75 137
BED3W IC 33 1051 620 51 30
CABANA 76 2098 1293 101 62
BATH 2 60 1446 1129 70 54
UTILITY 49 197 694 9 33
MECH 36 860 631 41 30
Calculations approved byACCA to meeLall requirements of Manual J 8th Ed.
wrightsoft- 74:47ot
R ipt-Sri�Jlknvn12027 31!J.Q2 RSUi3c ?aye t
�� ..�sivryUsorlr�nntt'�.Yr:gic:o'.!h�lACL17W-tfi91� Calc=AUc FroiEL�ri�s:.5 '
MASTER BATH 226 4340 2817 209 135
B®2 180 1884 2954 87 141
Entire House 2281 3204 32792 1567 1567
Other equip toads p 0
Equip.@ 0.95 RSM 31152
Latent cooling 11604
TOTALS 22M1 MR 42757 1567 1567
Catcuiagons approved byACCAto meetag neqdranmftofManual J n Ed.
wr[gh�opt-
AOGi\ �,�" ��*s'rD®u"�`e+s�2axr2uo�o2as �,,reM1tstaxtao
,+s► MhVAC aV-1G& a Cac-awe Ragowrtma s Pez
Jabc
wri htsofte Project Summary Date: Jan 11,2021
9 Entire House air
Project • •
For. MW-168 9 CT FORT PIERCE FL 34951
Motes:
Design
Weans. Vero Beach,FL,US
Winter Design Condithm Summer Design Conditions
Outside db 43 OF Outside db 90 OF
Inside db 70 OF Inside db 72 OF
Design 27 OF DedgrnarTtgDe 1L OF
DalRelative humidly 50 %
Moistruredifietenoe 68 gdib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 26M Stuh Structure 25789 Btuh
Duds 5W8 Btuh Duos 7003 Btuuh
Central vent(0 dm) 0 Bluh Central md(0dm) 0 Btuh
Hur(none
dilichlon 0 Bbih Blower 0 Btuh
Eq�up ent load 32554 �h Use mRateanutctuuntsds data n
Infiltration 6quipmerd ibie oad 310152 Btuh
Method
fiction quality Simples Latent Cooling Equipment Load Sing
Fireplaces 0 Structure 9319 Btuh
Coottna Ducts Central vent(0 dm) �0 BBb uh
Area(ft- 22Hea"80 2291 Bq*merit latent load 11604 Bbuh
Volume(fe) 23185 23185
Air 0.11 0M tEquipmwd Total Load((Sen+Lat} 42757 Btuh
Equiv. 43 23 Req.total capacity at0:70 SHR 3.7 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make Lep=
Model Cord ML1 4XC1.047 230A"
AHRI ref Coil C8A27UHE 048-230'++TDR
AHM ref 10259428
M!Ef6ci 100 EFF ORcietxy 13.0 EER,16 SEER
d=q nput 10.0 kW Sensible cooling 32900 Btuh
Heating output 34W5 Btuh Latentcooling 14100 Btuh
Temperas n rise 20 OF Total cooling 47000 Btuh
Actual airflow 1567 dm Actual afrtlaw 1587 dm
Airftowfaacr 0.048 df VBtuh Airficw�r 0.048 dh Btuh
Static pressure 0 in H2O Staec pressure 0 In H2O
Space thermostat Load sensible heat ratio 0.74
Calculations approved byACCA to mod all requirements of Martial J 8th Ed.
-00-. !M*tW-vL- 2021.,m-0214%W4
U twomd2Ml 21D.02 aSU23M pop I
e:yrmoarnmoa�w-�eeno (,�tca4tla Fnac000rQ;�s s
ANA s:t'u% G�, '•-... COYEFEG
,ddK
.r• s, VASTER
SUITE
:n..:a.
emocu 3
`w II ro o GMT RON
eor.
e VIPt - KT ;I -HNI _ —
I SEDROW 2 1. c• a V q +� o.fi - r
Ei I) 29 CF k� J :y� •�
HERS
c.1: BATH 2 \-I
�1 - I n •4.
FOYER +� " a
ri c�v
11 ��{I
E uzal /t {/ ddM5E0
l
o I ENTRY S Or BAT{{
.u2 { '
.CAETUA:.r:�uc3a•:".JX
adOH
® 2 CAR GARAGE
iI
II
GHO HOMES
MW- 168
9406 PINEBARK CT
FORT PIERCE, FL 34951