Loading...
HomeMy WebLinkAboutEPL Display Card4. FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 RECEIVED The lower the EnergyPerformance Index, the more efficient the home. NOV ® 2 7U21 Permitting Department 1912 Lynx Drive, Fort Pierce, FL, 34949 St. Lucie count), 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft') 7. Windows** Description a. U-Factor. Dbl, U=0.75 SHGC: SHGC=0.50 b. U-Factor. N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor. N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block- Int Insul, Exterior R=4.1 2056.30 ft' b. Frame -Wood, Adjacent R=11.0 310.00 ft' 1 c. Interior Frame -Wood, Interior R=11.0 65.00 ft' 3 d. N/A R= ft' 11. Ceiling Type and insulation level Insulation Area No a. Under Attic (Vented) R=30.0 2163.00 ft' 2163 b. Knee Wall (Vented) R=30.0 68.00 ft' c. N/A R= ft' Area 12. Ducts, location & Insulation level R ft' 342.67 ft' a. Sup: Attic, Ret: Attic, AH: Garage 6 560 ft2 13. Cooling systems kBtu/hr Efficiency ft' a. Central Unit 54.6 SEER:17.00 ft' 7.915 ft. 0.500 Area ft' 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 2163.00 ft' b. N/A R= ft' c. N/A R= ft' 14. Heating systems a. Electric Heat Pump 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficier Construction through the above energy saving features which will be in this home before final inspection. Otherwise, a new EPL Display based on installed Code com t fe ures. Builder Signature, Address of New Home: y� Z �j,X C *Note: This is not a Building Energy Rating. If your Index is b mortgage (EEM) incentives if you obtain a Florida Energy Ratir Energy Conservation, contact the Florida Building Commission . __r1r1_' - -1-11, kBtu/hr Efficiency 53.6 HSPF:9.50 Cap: 50 gallons EF: 0.95 **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. Pstat 7/30/2021 3:40 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: DieulioResidence BuilderName: P&VProperties Street: 1912 Lynx Drive Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL , 34949 Permit Number. TBD Owner. Dan and Stephanie Dieulio Jurisdiction: 661000 DesignLocation: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Types(2431.3 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block- Int Insul, Exterior R=4.1 2056.30 ft2 b. Frame - Wood, Adjacent R=11.0 310.00 ft2 3. Number of units, if multiple family 1 c. Interior Frame -Wood, Interior R=11.0 65.00 ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Types (2231.0 sqft.) Insulation Area 5. Is this a worst case? No a. UnderAttic (Vented) R=30.0 2163.00 ft2 6. Conditioned floor area above grade (ft2) 2163 b. Knee Wall (Vented) R=30.0 68.00 ft2 Conditioned floorarea belowgrade (ft2) 0 c. N/A R= ft2 7. Windows(342.7 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ft2 6 560 a. U-Factor: Dbl, U=0.75 342.67 ft2 SHGC: SHGC=0.50 b. U-Factor. N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 54.6 SEER:17.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 7.915 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.500 a. Electric Heat Pump 53.6 HSPF:9.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 60 gallons 9. Floor Types (2163.0 sqft.) Insulation Area EF:0.950 a. Slab -On -Grade Edge Insulation R=0.0 2163.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.158 Total Proposed Modified Loads: 67.37 PASS Total Baseline Loads: 71.29 I hereby certify that the plans and specifications covered by Review of the plans and it HE S7, this calculation are in compliance with the Florida Energy specifications covered by this 4�� 80�, Code. Digitally signed by 7I95 rjhomas V Platanla calculation indicates compliance�i,, ' ClC18152U Pr.Wa, LLc _ Datep2021.0730 with the Florida Energy Code. PREPARED BY: 08:1930-04-00r DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as ned, is in compliance Florida Statutes. with the Florida Energy Cod 0 ? we OWNER/AGENT- BUILDING OFFICIAL: DATE: Z DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 7/30/2021 3:40 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: DieulioResidence Bedrooms: 3 Address Type: StreetAddress Building Type: User ConditionedArea: 2163 Lot# TBD OwnerName: Dan and Stephanie Dieulio Total Stories: 1 Block/Subdivision: TBD # of Units: 1 Worst Case: No PlatBook: TBD BuilderName: P&VProperfles RotateAngle: 0 Street: 1912LynxDrive Permit Office: St. Lucie County CrossVentilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce, FamilyType: Detached FL, 34949 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design DailyTemp V Design Location TMY Site 97.5 % 2.5 % Winter Summer DegreeDays Moisture Range FL, ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 ENTIRE HOUSE 2163 22373 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 237 2370 No 0 1 1 Yes Yes Yes 2 M WIC 92 920 No 0 1 Yes Yes Yes 3 LAUNDRY 88 880 No 0 1 Yes Yes Yes 4 DINING 233 2563 No 0 1 Yes Yes Yes 5 MUD ROOM 118 1180 No 0 1 Yes Yes Yes 6 BEDROOM 1 206 2060 No 0 1 1 Yes Yes Yes 7 BEDROOM 2 172 1720 No 0 1 1 Yes Yes Yes 8 PDR 50 500 No 0 1 Yes Yes Yes 9 HALL 220 2200 No 0 1 Yes Yes Yes 10 KITCHEN 154 1694 Yes 1 1 Yes Yes Yes 11 LIVING 356 3916 No 3 1 Yes Yes Yes 12 M TOILET 26 260 No 0 1 Yes Yes Yes 13 M BATH 118 1180 No 0 1 Yes Yes Yes 14 BATH1 63 630 No 0 1 Yes Yes Yes 15 TOILET 1 30 300 No 0 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 37.3 ft 0 237 ft2 __ 1 0 0 2 Slab -On -Grade Edge Insulation M WIC 7.5 ft 0 92 ft2 __-_ 1 0 0 3 Slab -On -Grade Edge Insulation LAUNDRY 20 ft 0 88 ft2 --_- 1 0 0 7/30/2021 3:40 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR Value Tile Wood Carpet 4 Slab -On -Grade Edge Insulation DINING 19 ft 0 233 ft2 -- 1 0 0 5Slab-On-Grade Edge Insulation MUD ROOM 9.5ft 0 118fN ---- 1 0 0 6 Slab -On -Grade Edge Insulation BEDROOM 1 45 ft 0 206 ft2 ---- 1 0 0 7 Slab -On -Grade Edge Insulation BEDROOM 2 16 ft 0 172 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulation PDR E ft 0 50 f12 ---- 1 0 0 9 Slab -On -Grade Edge Insulation HALL 21 ft 0 220 ft2 ---- 1 0 0 1OSlab-On-Grade Edge Insulation KITCHEN 1 ft 0 154ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulation LIVING 34ft 0 356ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulation M TOILET 6.5 ft 0 26 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulation MBATH 6.5ft 0 118ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulation BATH 1 5.5 ft 0 63 ft2 ---- 1 0 0 15SIab-On-GradeEdge Insulation TOILET 1 4 ft 0 30 ft2 ---- 1 0 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable orshed Composition shingles 2343 ft2 450 ft2 Medium N 0.85 No 0.9 No 0 22.62 ATTIC RBS IRCC V # Type Ventilation Vent Ratio (1 in) Area 1 Full attic Vented 150 2163 ft2 N N CEILING # Ceiling Type Space R Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 237 ft2 0.11 Wood 2 Under Attic (Vented) M WIC 30 Blown 92ft2 0.11 Wood 3 Under Attic (Vented) LAUNDRY 30 Blown 88 ft2 0.11 Wood 4 Under Attic (Vented) DINING 30 Blown 233ft2 0.11 Wood 5 Under Attic (Vented) MUD ROOM 30 Blown 118 ft2 0.11 Wood 6 Under Attic (Vented) BEDROOM 1 30 Blown 206ft2 0.11 Wood 7 Under Attic (Vented) BEDROOM 2 30 Blown 172 ft2 0.11 Wood 8 Under Attic (Vented) PDR 30 Blown 50 ft2 0.11 Wood 9 Under Attic (Vented) HALL 30 Blown 220 ft2 0.11 Wood 10 Under Attic (Vented) KITCHEN 30 Blown 154ft2 0.11 Wood 11 Under Attic (Vented) LIVING 30 Blown 356ft2 0.11 Wood 12 Under Attic (Vented) M TOILET 30 Blown 26 ft2 0.11 Wood 13 Under Attic (Vented) M BATH 30 Blown 118 ft2 0.11 Wood 14 Under Attic (Vented) BATH 1 30 Blown 63 ft2 0.11 Wood 15 Under Attic (Vented) TOILET 1 30 Blown 30 ft2 0.11 Wood 16 Knee Wall (Vented) LIVING 30 Blown 68 ft2 0.11 Wood FORM R405-2020 INPUT 5UMMAKY CHEGKLI5T KEPOK 1 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # ()Mt To Wall 1upeSpace 1 N Exterior Concrete Block- Int InsuMASTER BE 4.1 5 4 10 0 53.3 ft2 0 0 0.5 0 2 NE Exterior Concrete Block - Int InsuMASTER BE 4.1 5 D 10 0 50.0 fe 0 0 0.5 0 3 SW Exterior Concrete Block- Int InsuMASTER BE 4.1 15 6 10 0 155.0 ft2 0 0 0.5 0 4 NW Exterior Concrete Block - Int InsuMASTER BE 4.1 11 6 10 0 115.0 ft2 0 0 0.5 0 5 SW Exterior Concrete Block- Int Insul M WIC 4.1 7 6 10 0 75.0 ft2 0 0 0.5 0 6 SW Exterior Concrete Block - Int Insul LAUNDRY 4.1 13 6 10 0 135.0 ft2 0 0 0.5 0 7 SE MASTER Interior Frame - Wood LAUNDRY 11 6 6 10 0 65.0 ft2 0 0.25 0.8 0 8 NE Exterior Concrete Block- Int Insul DINING 4.1 5 6 11 0 60.5 ft2 0 0 0.5 0 9 NW Exterior Concrete Block- Int Insul DINING 4.1 13 6 11 0 148.5 ft2 0 0 0.5 0 10 SE Garage Frame - Wood MUD ROOM 11 9 6 10 0 95.0 ft2 0 0.23 0.01 0 11 NE Exterior Concrete Block - Int InsuBEDROOM 1 4.1 17 6 10 0 175.0 ft2 0 0 0.5 0 12 SE Exterior Concrete Block - Int InsuBEDROOM 1 4.1 12 6 10 0 125.0 ft2 0 0 0.5 0 13 SW Exterior Concrete Block- Int InsuBEDROOM 1 4.1 15 0 10 0 150.0 112 0 0 0.5 0 14 NE Exterior Concrete Block- Int InsuBEDROOM 2 4.1 16 0 10 0 160.0 112 0 0 0.5 0 15 SE Garage Frame - Wood PDR 11 5 6 10 0 55.0 ft2 0 0.23 0.01 0 _ 16 SW Garage Frame - Wood PDR 11 0 6 10 0 5.0 ft2 0 0.23 0.01 0 17 SE Exterior Concrete Block - Int Insul HALL 4.1 5 6 1 D 0 55.0 ft2 0 0 0.5 0 18 SW Garage Frame - Wood HALL 11 15 6 10 0 155.0 ft2 0 0.23 0.01 0 19 NE Exterior Concrete Block - Int Insul LIVING 4.1 23 6 11 0 258.5 ft2 0 0 0.5 0 20 NW Exterior Concrete Block - Int Insul LIVING 4.1 10 6 11 0 115.5 ft2 0 0 0.5 0 21 SW Exterior Concrete Block- Int Insul M TOILET 4.1 6 6 10 0 65.0 ft2 0 0 0.5 0 22 SW Exterior Concrete Block- Int Insul M BATH 4.1 6 6 10 0 65.0 ft2 0 0 0.5 0 23 NE Exterior Concrete Block- Int Insul BATH 1 4.1 5 6 10 0 55.0 ft2 0 0 0.5 0 24 NE Exterior Concrete Block- Int Insul TOILET 1 4.1 4 0 10 0 40.0 ft2 0 0 0.5 0 DOORS # Omt DoorType Space Storms U Value Width Height Area Ft In Ft In 1 SE Wood HALL None .33 3 8 24 ft2 2 SE Wood MUD ROOM None .33 3 6 8 20 ft2 WINDOWS Orientation shown isthe entered, Proposed orientation. Wall Overhang v # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 N 1 Vinyl Double(Clear) Yes 0.75 0.5 Y 22.7 ft2 9 ft 6 in 1 ft 0 in None None 2 SW 3 Vinyl Double(Clear) Yes 0.75 0.5 Y 16.5 ft2 1 ft 6 in 1 ft 0 in None None 3 NW 4 Vinyl Double(Clear) Yes 0.75 0.5 Y 36.0 ft2 8 ft 0 in 1 ft 0 in None None 4 SW 5 Vinyl Double(Clear) Yes 0.75 0.5 Y 5.0 ft2 1 ft 6 in 1 ft 0 in None None 5 SW 6 Vinyl Double(Clear) Yes 0.75 0.5 Y 9.0 ft2 1 ft 6 in 1 ft 0 in None None 6 NE 8 Vinyl Double(Clear) Yes 0.75 0.5 Y 18.0 ft2 1 ft 6 in 1 ft 0 in None None 7 NW 9 Vinyl Double(Ciear) Yes 0.75 0.5 Y 54.0 ft2 16 ft 0 in 1 ft 0 in None None 8 NE 11 Vinyl Double(Clear) Yes 0.75 0.5 Y 18.0 ft2 1 ft 6 in 1 ft 0 in None None 9 SE 12 Vinyl Double(Ciear) Yes 0.75 0.5 Y 24.0 ft2 0 ft 0 in 0 ft 0 in None None 7/30/2021 3:40 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Omt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation IntShade Screening 10 11 12 13 14 15 16 NE 14 Vinyl Double(Clear) Yes SE 17 Vinyl Double(Clear) Yes NE 19 Vinyl Double(Clear) Yes NW 20 Vinyl Double(Clear) Yes SW 21 Vinyl Double(Clear) Yes SW 22 Vinyl Double(Clear) Yes NE 23 Vinyl Double(Clear) Yes 0.75 0.5 Y 15.0 ft' 1 ft 6 in 1 ft 0 in 0.75 0.5 Y 8.0 ft' 8 ft 0 in 1 ft 0 in 0.75 0.5 Y 36.0 ft' 1 ft 6 in 1 ft 0 in 0.75 0.5 Y 48.0 ft' 22 ft 0 in 1 ft 0 in 0.75 0.5 Y 6.0 ft' 1 ft 6 in 1 ft 0 in 0.75 0.5 Y 8.5 ft' 1 ft 6 in 1 ft 0 in 0.75 0.5 Y 18.0 ft' 1 ft 6 in 1 ft 0 in None None None None None None None None None None None None None None GARAGE # FloorArea Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 548.25 W 548.25 ft' 94 ft loft 0 INFILTRATION # Scope Method SLA CFM 50 EL.A EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000328 1864.4 102.29 192.03 .1 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:9.5 53.6 kBtu/hr 1 sys#1 COOLING SYSTEM # SystemType Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 CentralUnit/ Split Single SEER:17 54.6 kBtu/hr 1785 cfm 0.85 1 sys#1 HOT WATER SYSTEM # SystemType SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # CompanyName Collector System Model# Collector Model# Area Storage Volume FEF None None ft' DUCTS V # - Supply - - Return -- Air CFM 25 CFM25 Location R-Value Area Location Area LeakageType Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 560 ft' Attic 377.8 ft' DefaultLeakage Garage (Default) c(Defauft) c 1 1 7/30/2021 3:40 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES ProgramableThermostat: Y Ceiling Fans: CoolingH Jan H Feb HeatinJan Feb [[ ]] Mar [X] Mar [ ] A r [ ] Apr I Ma May Jun rl Jun r Jul 11 Jul Au f Aug P Se Sep [ ] Oct MNov [ ] Oct Nov Dec Dec Ventin Jan Feb [[XXJ) Mar [X] A r May Jun E ] Jul [ Aug Sep (Xl Oct Nov Dec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(81bs/sq.ft. 0 ft2 Oft 0.3 MASTER BEDROO Default(8lbs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft2 ft 0.3 DINING Default(8lbs/sq.ft. ft2 ft 0.3 MUD ROOM Default(8lbs/sq.ft. ft2 ft 0.3 BEDROOM 1 Default(8lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 PDR DefauR(8 lbs/sq.ft. ft2 It 0.3 HALL Default(8 lbs/sq.ft. ft2 It 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING Default(8lbs/sq.ft. ft2 It 0.3 M TOILET Default(8lbs/sq.ft. ft2 ft 0.3 M BATH Default(8lbs/sq.ft. ft2 ft 0.3 BATH 1 Default(8lbs/s .ft. ft2 ft 0.3 TOILET 1 7/30/2021 3:40 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6