Loading...
HomeMy WebLinkAboutFlood Elevation final packetFTrJ NNING DEVELOPMENT" S 2300 VIRGHaA AVENUE I i DIVISION 462-196o I TDD w2) 462-142s i www-smuc[Eco.Gov Memo of EC Review for Correctness and Completion The attached FEMA Elevation Certificate for the following address has been reviewed by this office. 1844 WILDCAT COVE DR 11603-0374) The items noted below are not correct on the attached form and should read as entered on this page. SECTION A - PROPERTY INFORMATION For Insurance Company Use: �. Al. Building Owner's Name Policy Number -... -- A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. I company r n. rvuncdei., city State ZIP Code A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) A5. Latitude/Longitude: Lat. Long. Horizontal Datum: NAD 1927 NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. AT A8. Building Diagram Number. I For a building with a crawlspace or enclosure(s): A9. For a building with an attached garage: a) Square footage of crawlspace or enclosure(s) sq ft a) Square footage of attached garage sq ft b) No. of permanent flood openings in the crawlspace or b) No. of permanent flood openings in the attached garage enclosure(s) within 1.0 foot above adjacent grade within 1.0 foot above adjacent grade c) Total net area of flood openings in A8.b sq in c) Total net area of flood openings in A9.b sq in d) Engineered flood openings? Yes No d) Engineered flood openings? Yes No SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B4. Map/Panel Number B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) (Zone AO, use base flood depth) Date I Effective/Revised Date Zone(s) BID. Indicate the source of the Base Flood Elevation (BFE) data or base flood depm entered in uem dn. FIS FIRM Community Determined Other (Describe) B11. Indicate elevation datum used for BFE in Item B9: NGVD 1929 NAVD 1988 Other (Describe) B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Proteded Area (OPA)? Yes No Designation Date CBRS OPA Local Official's Name: Leslie Olson, AICP Title: Director, Planning and Development Services Community Name: St. Lucie County (Unincorporated Areas) Telephone: 772-462-1960 Uate: I CBS 310 FEMA EC CORAEC [ON MEMO ST. LU C I E U.S. DEPARTMENT OF HOMELAND z�,CCURITY OMB No. 1660-0008 Federal Emergency Management Agency Expiration Date: November 30, 2018 National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. SECTION A — PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Policy Number: Andrew J. Stefanik and Lynn M. Stefanik A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Company NAIC Number: Box No. 1844 Wildcat Cove Drive City State ZIP Code Ft. Pierce Florida A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Lot 44, Riverpoint at the Sands Phase II A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential A5. Latitude/Longitude: Lat. 27° 29' 32.31" Long, 80° 18' 21.66" Horizontal Datum: ❑ NAD 1927 ❑x NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. AT Building Diagram Number 1A A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) 0 sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade 0 c) Total net area of flood openings in A8.1b 0 sq in d) Engineered flood openings? ❑ Yes ❑x No A9. For a building with an attached garage: a) Square footage of attached garage 533 sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 0 c) Total net area of flood openings in A9.b 0 sq in d) Engineered flood openings? ❑ Yes x❑ No SECTION B—FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State St. Lucie County 120285 St. Lucie Florida B4. Map/Panel B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood Zone(s) B9. Base Flood Elevation(s) Number Date Effective/ (Zone AO, use Base Revised Date Flood Depth) 12111CO181 J 02/16/2012 02/16/2012 AE 5 B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item 69: ❑ FIS Profile ❑x FIRM ❑ Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item 139: ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ❑x No Designation Date: ❑ CBRS ❑ OPA FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 1 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding Information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 1844 Wildcat Cove Drive , City State ZIP Code Company NAIC Number Ft. Pierce Florida SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings' ❑ Building Under Construction" ❑x Finished Construction •A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations — Zones Al—A30, AE, AH, A (with BFE), VE, VI—V30, V (with BFE), AR, ARIA, AR/AE, AR/A1—A30, AR/AH, AR/AO. Complete Items C2.a—h below according to the building diagram specified in Item AT In Puerto Rico only, enter meters. Benchmark Utilized: 94 77 A 29 Vertical Datum: NAVD 88 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 0 NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 5.49 x❑ feet ❑ meters b) Top of the next higher floor N/A. El feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) N/A. 0 feet ❑ meters d) Attached garage (top of slab) 5. 10 0 feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building 5. 13 0 feet ❑ meters (Describe type of equipment and location in Comments) 0 Lowest adjacent (finished) grade next to building (LAG) 4, 25 x❑ feet El meters g) Highest adjacent (finished) grade next to building (HAG) 5 16 ❑X feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including N/A. ❑x feet ❑ meters structural support SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. i certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine orimprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? 0 Yes ❑ No ❑ Check here if attachm nts. Certifier's Name License Number • `" Michael T. Owen L55556 -. Title` Vice President _ Company Name Engineering, Design & Construction, Inc. ' Seal - Address 10250 SW Village Parkway, Suite 201 gyp 1 �•' y City State ZIP Code Port St. Lucie Florida 34987-2362 Signatur Date Telephone 02/13/2017 (772) 462-2455 Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agentloompany, and (3) building owner. Comments (including type of equipment and location, per C2(e), if applicable) Equipment in Section C.2.e) is air conditioner condenser servicing house. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 2 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 1844 Wildcat Cove Drive City State ZIP Code Company NAIC Number Ft. Pierce Florida SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) Far Zones AO and A (without BFE), complete Items El—E5. If the Certificate is Intended to support a LOMA or LOMR-F request, complete Sections A, B,and C. For Items El—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is NIA. ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is N/A , ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 1-2 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is N/A. ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is N/A . ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment N/A servicing the building Is . ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F— PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -Issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name N/A Address City State ZIP Code N/A N/A N/A Signature Date Telephone Comments N/A ❑ Check here if attachments. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 3 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 1844 Wildcat Cove Drive City State ZIP Code Company NAIC Number Ft. Pierce Florida SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8-G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4-G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued N/A G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) ❑ feet ❑ meters Datum of the building: G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters Datum G10. Community's design flood elevation: ❑ feet ❑ meters Datum Local Official's Name Title N/A N/A Community Name Telephone N/A Signature Date Comments (including type of equipment and location, per C2(e), if applicable) N/A ❑ Check here if attachments. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 4 of 6 BUILDING PHOTOGRAPHS OMB No. 1660-0008 ELEVATION CERTIFICATE See Instructions for Item A6. Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 1844 Wildcat Cove Drive City State ZIP Code Company NAIC Number Ft. Pierce Florida If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. r Photo One Photo One Caption Front View - Taken 2.11.17 b Photo Two Photo Two Caption Northeast corner - Taken 2.10.17 FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 5 of 6 ELEVATION CERTIFICATE BUILDING PHOTOGRAPHS OMB No. 1660-0008 Continuation Page Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 1844 Wildcat Cove Drive City State ZIP Code Company NAIC Number Ft, Pierce Florida If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and 'Rear View'; and, if required, 'Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the Flood openings or vents, as Indicated in Section A8. r. .y 4 Photo One Photo One Caption Northwest corner - Taken 2.10.17 Photo Two Photo Two Caption West side - Taken 2.10.17 FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 6 of 6 �1� Gl) P� N50'35'56"E 0.83'(P� QG N50.24'31"E 0.83(C) CONSERVATION EASEMENT (O.R.B. 1232, PAGE 2001) F,2,5\1 s yya6�F s� FOUND 5/8" IRON ROD �yrRL'N�ti JFF�� \. 1.11'I SOUTHWESTOOF PROPERTY LINE MEAN HIGH WATER LINE PER PLAT / of s BENCHMARK NO. 1 t / �,�OQ �C• �B�+JB LOT 43 FOUND 5/8" IRON RO •� ? F•��., (OCCUPIED) (NO IDENTIFICATION) s'0. ELEVATION 2.03 FEET (N.A.V.D.) Q O_,pJ O '0. sIT S 00n tx sw LOT 45 �, �J• Co. (VACANT) ��. 'fa• (`\, � � a $t • C dd Opte 910N ry y- a FOUND 5/8" IRON ROD 60472' (NO IDENTIFICATION) / N43.5057"W 25.00'(C) / N43'39'32"W 25.00'(P) FOUND "X" CUT 4' IN CONC. CURB �07. CURB 0.12' NORTHWEST COT 4S A=30'40'29"(P)(M) / 4.01 R6. R=77.00' L=41.22' / 2' CONC. VALL�V CURB / , K4.12 FOUNqq X" CUTS' IN CONC. CURB I i BENCHMARK NO. 2 FOUND "X" CUT IN CONC. CURB CURB 0.11' NORTHWEST ELEVATION 4.16 FEET / (N.A.V.D) / 4' PAV R/ 0111 6P SID WALK �. / 9� / ,\ Gµµ O4.2t64P ryti { � y�P FOUND "X" CUT 4.06 \G�IN CONC. CURB CURB 0.12' NORTHWEST 9 2' CONC. VALLEY CURB `0=5•16'22"(P)(C) R=77.00' L=7.09' MICHAEL T. OWEN P FLORIDA REGISTRATI GRAPHIC SCALE 30 0 15 30 ( IN Fm) 1 Imh - 80 tL LEGAL DESCRIPTION LOT 44, RIVERPOINTE AT THE SANDS - PHASE II, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 43, PAGES 16, 16A, PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. LEGEND (P) PLAT DATA (F) FIELD DATA (C) CALCULATED FROM FIELD MEASUREMENTS FND. FOUND P.C.C. POINT OF COMPOUND CURVE P.R.C. POINT OF REVERSE CURVE P.L.S. PROFESSIONAL LAND SURVEYOR L.B. LICENSED BUSINESS T.E. TELECOMMUNICATIONS EASEMENT 0 DELTA (CENTRAL ANGLE) R RADIUS L ARC LENGTH CB CHORD BEARING PC POINT OF CURVE PT POINT OF TANGENCY CL CENTERLINE No. NUMBER TYP TYPICAL EL. ELEVATION CONC CONCRETE WM WATER METER TOB TOP OF BANK (AD) RADIAL LINE SET 5/8" IRON ROD & CAP STAMPED "LB 7673" SANITARY CLEAN OUT HAND HOLE T TELEPHONE BOX . .V.D. NORTH AMERICAN VERTICAL DATUM DRAINAGE FLOW NOTES 1) NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. 2) ADDITIONS OF DELETIONS TO SURVEY MAPS OR REPORTS, BY OTHER THAN THE SIGNING SURVEYOR IS PROHIBITED, WITHOUT CONSENT OF THE SIGNING SURVEYOR. 3) DESCRIPTION SHOWN HEREON PROVIDED BY CLIENT AND/OR THEIR AGENT. 4) OVERALL PARCEL CONTAINS 9,767 SQUARE FEET OR 0.22 ACRES, MORE OR LESS. 5) THE LAST DATE OF FIELD WORK WAS MAY 18. 2016. 6) LANDS SHOWN HEREON WERE NOT ABSTRACTED BY THIS OFFICE FOR RIGHT-OF-WAYS, RESERVATIONS, AGREEMENTS, AND/OR EASEMENTS OF RECORD. SUCH INFORMATION SHOULD BE OBTAINED AND CONFIRMED BY OTHERS THROUGH APPROPRIATE TITLE VERIFICATION. 7) THE NORTHWESTERLY RIGHT OF WAY LINE OF WILDCAT COVE DRIVE IS TAKEN TO BEAR NORTH 51'25'25" EAST AND ALL OTHER BEARINGS SHOWN HEREON ARE RELATIVE THERETO. 8) UNDERGROUND UTILITIES, UTILITY SERVICES, FOUNDATIONS AND IMPROVEMENTS WERE NOT LOCATED AS A PART OF THIS SURVEY. 9) ELEVATIONS SHOWN HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88) AND REFERENCE NATIONAL GEODETIC SURVEY CONTROL POINT "94 77 A 29", HAVING AN ELEVATION OF 5.80 FEET. 10) BY GRAPHIC PLOTTING ONLY, SAID DESCRIBED PROPERTY IS LOCATED WITHIN AN AREA HAVING A FLOOD ZONE DESIGNATION "AE" WITH A BASE ,FLOOD ELEVATION OF "5" BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY (g.E.M.A.) ON FLOOD INSURANCE RATE MAP NO. 12111CO181J PATH A DATE OF !IDENTIFICATION OF FEBRUARY 16, 2012, (SN}AL SURVEYOR AND MAPPER K,.. SIGNATURE t` 0) Y d 1p 00 aa C4 in I QLL O IL J Iil't 00 >UN WF �Jn alav V) 0 E OF ILL to F- 2 N, .n 0 H V N 0 0 � 2 v12 O Q s �L 4 V O 4 �� 0 O Ll D 4 0 F- C, y <:tEL f ° %mow a OL y O \ as W V1 N SHEET o cn OF Z