HomeMy WebLinkAboutCertification Design Load CompliancePlanning & Development Services Department
• Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: S1' 4n )Gf� y7
Project Address: 3061 iJV 'Ro,d C<<<Ft W9a A14A 66
Permit #: Occupancy Type: �' 3 Construction Type: �!(j
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida ul, 6% Code 2010 Edition with 20 Supplements using ASCE 7-10
2. Structure Designed as (check one): Enclosed Partially Enclosed Open
3. Risk Category: _I 11 III IV Exposure Category: B K_C D
4. Design Wind Velocity ) 0 mph ASD LRFD End Zone Width: ft
5. Mean Roof Height ZS=O It ft Roof Pitch: S :12 Parapet: ,A- ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone1:'38.3 Zone2: -Gb'9 Zone1-98*� Zone 4:-4S•4 Zone5:,516'0 Garage:+3fS'S/434.J
7. Design Loads: Floor: _PSF Roof/Dead: PSF Roof/Live: Balcony: 7S PSF
Dock: PSF Deck: PSF Stairs: VO PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? ,Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: Z S Gv PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify,t,�qstdthVIp'p t of my knowledge and belief, the attached plans & specifications have been designed to
corn�p4�y�F�:al�structural portions of the building codes currently adopted and enforced by St. Lucie
ciaZn�y.,•�o fq.tt �uctural elements depicted on these plans provide adequate resistance to the design
�rces•sp ed: y
Acs A 339i�
Print Name Cert # & Co. Cert Auth.
T OF
AN. AN
Sign� ]?"o N• ''C-26-P-At ffs/Y sgZ7-L_ °G/t UMN
'''MAR 2 6 2014 Company Name & Address 33Y?(
SLCCDV Form # 020-12 Revised 3/15/12 (JS)