HomeMy WebLinkAboutAPPROVED NOA - Metal panels
NOA No: 18-0711.14
Expiration Date: 08/09/2023
Approval Date: 08/09/2018
Page 1 of 9
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Extreme Metal Fabricators, LLC
2160 SW Poma Drive
Palm City, FL 34990
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami-Dade County) and/ or the AHJ (in areas other than Miami-Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Series 1300 Aluminum 0.032” Panel over Wood Deck
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has bee n no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 16-0125.01 and consists of pages 1 through 9.
The submitted documentation was reviewed by Freddy Semino
NOA No: 18-0711.14
Expiration Date: 08/09/2023
Approval Date: 08/09/2018
Page 2 of 9
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Metal, Panels (Non-Structural)
Material: Aluminum
Deck Type: Wood
Maximum Design Pressure See Table A Below
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product
Dimensions
Test
Specifications
Product
Description
Series 1300 l = various
w = 16” or 20”
Thickness = 0.032”
Min. Yield Strength: 24 ksi
TAS 110
TAS 125
Aluminum, preformed, standing seam,
coated panels.
Series 1300 6” Clip l = 6-¼”
w = 1-½”
h = 1-11/16”
Thickness Min. = 0.024”
TAS 114 Corrosion resistant, formed, steel clips for
metal panel installation.
Series 1300 Two
Piece Floating Clip
l = 3”
w = ¾”
h = 1- ½”
Thickness Min. =
Top: 0.015”
Base: 0.030”
TAS 114 Corrosion resistant, two piece floating,
stainless steel clips for metal panel
installation.
Series 1300 3” Clip l = 3”
w = 1-3/16”
h = 1-5/8”
Thickness Min. = 0.024”
Corrosion resistant, formed, steel clips for
metal panel installation
Trim Pieces l = varies
w = varies
Thickness = 0.032”
TAS 110 Standard flashing and trim pieces.
Manufactured for each panel width.
TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS:
Product
Dimensions
Test
Specifications
Product
Description
Manufacturer
Bostik 70 0-5A N/A TAS 110 Heavy duty construction
adhesive.
Bostik, Inc.
NOA No: 18-0711.14
Expiration Date: 08/09/2023
Approval Date: 08/09/2018
Page 3 of 9
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report
Date
Architectural Testing, Inc.
01-32797.01
46064.01-122-18
B8192.01-109-18 R2
TAS 100
TAS 125
TAS 125
11/05/98
07/21/11
02/01/13
Hurricane Test
Laboratory, Inc.
0155 0404-04 TAS 125
05/21/04
BASF ASTM G23 11/15/04
ASTM B117
ATI/ Intertek F1488.01-109-18 TAS 125 05/05/16
NOA No: 18-0711.14
Expiration Date: 08/09/2023
Approval Date: 08/09/2018
Page 4 of 9
APPROVED ASSEMBLIES:
System A-1: Series 1300 Metal Roof Panels 16” wide
Deck Type: Wood, Non-Insulated
Deck Description: New Construction 19/32” or greater plywood or wood plank.
Slope Range: 2": 12" or greater
Maximum Uplift
Pressure:
See Table A below
Deck Attachment: Deck shall be attached in accordance with applicable Building Code, but in no case shall it
be less than 8d x 2-1/2” galvanized ring shank roofing nails spaced 6” o.c. at roof perimeter
and field. In reroofing, where the deck is less than 19/32” thick (Minimum 15/32”) the above
attachment method must be in addition to existing attachment.
Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4”
side-lap and 6” end-laps. Underlayment shall be fastened with corrosion resistant 32 gauge
tin-caps and 12 gauge 1-¼” annular galvanized ring-shank roofing nails, spaced 6” o.c. at
all laps and two staggered rows 12” o.c. in the field of the roll. Or, any approved
underlayment having a current NOA.
Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation # 1.
Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with Englert’s current published installation instructions.
Metal Panels and
Accessories:
Install the "Series 1300 Panel" and accessories in compliance with the current published
installation instructions and details in Englert’s Installation Manual. Flashings,
penetrations, valley construction and other details shall be constructed in compliance with
Roofing Application Standard RAS 133.
Each roof panel is attached to the plywood substrate along it’s male rib using the approved
Series 1300 6” Clip (6-¼” long x 1-½ ” wide x 1-11/16” tall) located 3” from each panel end
and at a spacing as listed in Table A below. Each clip is attached to substrate with four (4)
corrosion resistant #10 self tapping pan head screws of sufficient length to penetrate
through the sheathing a minimum of 3/16".
Attach adjacent panel by placing the female rib over the male rib and clip. Standing seams
shall be mechanically seamed to a full 180 degree seam, (double lock)
TABLE A
MAXIMUM DESIGN PRESSURES
Roof Areas Field Perimeter and Corner1
Maximum Design Pressures –55psf –123.5psf
Maximum Clip Spacing 24” o.c. 8” o.c.
1. Extrapolation shall not be allowed
NOA No: 18-0711.14
Expiration Date: 08/09/2023
Approval Date: 08/09/2018
Page 5 of 9
System B: Series 1300 Metal Roof Panels 16” or 20” wide
Deck Type: Wood, Non-Insulated
Deck Description: New Construction 19/32” or greater plywood or wood plank.
Slope Range: 2": 12" or greater
Maximum Uplift
Pressure:
See Table B below
Deck Attachment: Deck shall be attached in accordance with applicable Building Code, but in no case shall it
be less than 8d x 2-1/2” galvanized ring shank roofing nails spaced 6” o.c. at roof perimeter
and field. In reroofing, where the deck is less than 19/32” thick (Minimum 15/32”) the above
attachment method must be in addition to existing attachment.
Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4”
side-lap and 6” end-laps. Underlayment shall be fastened with corrosion resistant 32 gauge
tin-caps and 12 gauge 1-¼” annular galvanized ring-shank roofing nails, spaced 6” o.c. at
all laps and two staggered rows 12” o.c. in the field of the roll. Or, any approved
underlayment having a current NOA.
Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation # 1.
Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with Englert’s current published installation instructions.
Metal Panels and
Accessories:
Install the "Series 1300 Panel" and accessories in compliance with the current published
installation instructions and details in Englert’s Installation Manual. Flashings,
penetrations, valley construction and other details shall be constructed in compliance with
Roofing Application Standard RAS 133.
Each roof panel is attached to the plywood substrate along it’s male rib using the approved
Series 1300 Two Piece Floating Clip (3” long x ¾” wide x 1-1/2” tall) located 3” from each
panel end and at a spacing as listed in Table B below. Each clip is attached to substrate
with two (2) corrosion resistant #10 self tapping pan head screws of sufficient length to
penetrate through the sheathing a minimum of 3/16".
Attach adjacent panel by placing the female rib over the male rib and clip. Standing seams
shall be hand crimped to a 90 degree single lock, then mechanically seamed to a full 180
degree seam, (double lock).
TABLE B
MAXIMUM DESIGN PRESSURES
Roof Areas Field Perimeter and Corner1 Perimeter and Corner1
Maximum Design Pressures –101.25psf –142.5psf –180 psf
Maximum Clip Spacing 16” o.c. 8” o.c. 8” o.c.
Bostik 70-05A Adhesive None None (2) 1/8” beads in seam
1. Extrapolation shall not be allowed
NOA No: 18-0711.14
Expiration Date: 08/09/2023
Approval Date: 08/09/2018
Page 6 of 9
System C: Series 1300 Metal Roof Panels 16” or 20” wide
Deck Type: Wood, Non-Insulated
Deck Description: New Construction 19/32” or greater plywood or wood plank.
Slope Range: 2": 12" or greater
Maximum Uplift
Pressure:
See Table C below
Deck Attachment: Deck shall be attached in accordance with applicable Building Code, but in no case shall
it be less than 8d x 2-1/2” galvanized ring shank roofing nails spaced 6” o.c. at roof
perimeter and field. In reroofing, where the deck is less than 19/32” thick (Minimum
15/32”) the above attachment method must be in addition to existing attachment.
Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4”
side-lap and 6” end-laps. Underlayment shall be fastened with corrosion resistant 32
gauge tin-caps and 12 gauge 1-¼” annular galvanized ring-shank roofing nails, spaced 6”
o.c. at all laps and two staggered rows 12” o.c. in the field of the roll. Or, any approved
underlayment having a current NOA.
Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing
for fire ratings of this roofing system assembly as well as the location of the fire barrier
within the assembly. See Limitation # 1.
Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with Englert’s current published installation instructions.
Metal Panels and
Accessories:
Install the "Series 1300 Panel" and accessories in compliance with the current published
installation instructions and details in Englert’s Installation Manual. Flashings,
penetrations, valley construction and other details shall be constructed in compliance
with Roofing Application Standard RAS 133.
1. Each roof panel is attached to the plywood substrate along it’s male rib using the
approved clips located 3” from each panel end and at a spacing as listed in Table
C below. Clips are attached using #10 self-tapping pan head screws of sufficient
length to penetrate through the sheathing a minimum of 3/16".
2. Attach adjacent panel by placing the female rib over the male rib and clip.
Standing seams shall be mechanically seamed to a full 90 degree seam, (single
lock)
TABLE C
MAXIMUM DESIGN PRESSURES
Roof Areas Field Perimeter and Corner1
Maximum Design Pressures –86psf –97.5psf
Panel Clip Series 1300 3” Clip
(2 screws per clip)
(
Series 1300 6” Clip
(4 screws per clip)
Maximum Clip Spacing 12” o.c. 8” o.c.
Bostik 70-05A Adhesive 1/8” beads in seam 1/8” beads in seam
1. Extrapolation shall not be allowed
NOA No: 18-0711.14
Expiration Date: 08/09/2023
Approval Date: 08/09/2018
Page 7 of 9
SYSTEM LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended corners and corners).
3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in
Roofing Application Standard RAS 133
4. All panels shall be permanently labeled with the manufacturer’s name and/or logo, and the following statement:
“Miami-Dade County Product Control Approved” or with the Miami-Dade County Product Control Seal as seen
below. All clips shall be permanently labeled with the manufacturer’s name and/or logo, and/or model.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
6. Panels may be jobsite roll formed with machine model #’s 10811107, 0290414, 338213, 4260215 and 596019
from Englert, Inc.
NOA No: 18-0711.14
Expiration Date: 08/09/2023
Approval Date: 08/09/2018
Page 8 of 9
PROFILE DRAWINGS
SERIES 1300 METAL PANEL
SERIES 1300 6” CLIP SERIES 1300 TWO-PIECE FLOATING CLIP
3"
7/16"1-5/8"1-1/16"
SERIES 1300 3” CLIP
1-1/2"
16"
6-1/4"
1"
1-11/16"
NOA No: 18-0711.14
Expiration Date: 08/09/2023
Approval Date: 08/09/2018
Page 9 of 9
Before Seaming 90 degree
Seam
180 degree
Seam
END OF THIS ACCEPTANCE
90 degree
Seam w/Bostik
Sealant
Bostik Sealant
180 degree
Seam w/ (2) beads
of Bostik Sealant
Bostik Sealant