Loading...
HomeMy WebLinkAboutRHVAC Load CalculationsLaurel Model HVAC Load Calculations for Standard Pacific Homes RHVACHVAC: Prepared By: Greg Bolinsky Engineered Air LLC CACO45860 2520 N Andrews Ave Ext Pompano Beach, FL 33064 954 974-7277 Tuesday, November 12, 2013 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential 8't;ight Commercial HVAC Loads ati # " } ' Elite Software Development;, Inc.' `. Laurel Mosley Engineered Air; LLC Pa ..,�,•� ,i k ? System 1 A C 1- First Floor Summary Loads Com' onentn x W Area`w t� }, Sen + Lat �xSen r§Total; P,�r y; �wr� •:.. Desch bons; x�.�3`�d ��Quari�._# Loss:_Gam� �(,Gain� amp Lo-E French Door: Glazing-Low-E French Door, u-value 68 1,465 0 1,838 1,838 0.77, SHGC 0.22 Lo-E operable: Glazing-Low-E Operable Glass, u-value 208 3,496 0 4,805 4,805 0.6, SHGC 0.31 Lo-E S G D: Glazing -Low E Sliding Glass Door, ground 96 1,587 0 2,361 2,361 reflectance = 0.32, u-value 0.59, SHGC 0.32 11 D: Door -Wood - Solid Core 20 117 0 117 117 13A-4ocs: Wall -Block, board insulation only, R-4 board 1333 5,337 0 3,488 3,488 insulation, open core, siding finish 1213-0sw: Part -Frame, R-11 insulation in 2 x 4 stud 325 473 0 473 473 cavity, no board insulation, siding finish, wood studs 22A-pl: Floor -Slab on grade, No edge insulation, no 205 5,677 0 0 0 insulation below floor, any floor cover, passive, light dry_soil Subtotals for structure: 18,152 0 13,082 13,082 People: 6 1,800 1,680 3,480 Equipment: 4,600 3,000 7,600 Lighting: 700 2,387 2,387 Ductwork: 2,734 1,060 3,069 4,129 Infiltration: Winter CFM: 129, Summer CFM: 66 3,968 2,176 1,310 3,486 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 3,376 3,376 .System 1 AC 1 - First Floor Load Totals: 24,854 9,636 27,904 37,540 �.n�% "�ieckFi, f Supply CFM: 1,270 CFM Per Square ft.: 0.607 -Square ft. of Room Area: 2,091 Square ft. Per Ton: 668 Volume (ft3) of Cond. Space: 20,910 n 77,777 Total Heating Required Including Ventilation Air: 24,854 Btuh 24.854 MBH Total Sensible Gain: 27,904 Btuh 74 % Total Latent Gain: 9,636 Btuh 26 % Total Cooling Required Including Ventilation Air: 37,540 Btuh 3.13 Tons (Based On Sensible + Latent) Notes x � - ,. �� ,��k „��°• ����g� } _. .:rt, �,, , �:, {.ter ���, Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. S:\ ...\Stan Pac RB Laurel 5512 WBonus PSL.rh9 Tuesday, November 12, 2013, 10:14 AM at �iRhvad,-,Rdsidetibal,,&,Ligh't'�CoMRqrcial HVAC Loads a 'a Ehte,S&Waire Development,jnc. . t 3 Engineered AM.,1L , _ �� � ,, Laurel Model Mar ate,,FL,-W 63 -s • Pa e 5 System 2 AC 2 - Second Floor Summary Loads ^a3' i*: #' h. f r" Corri `o ent a 3 r h ., ,,r r 4,q 'Sena. I .>ILata Sen Totals fOR{ #"t*?�f yl, .?X'�tt3-3 f..x'�xj4ea reaaT bxr # �e N;�if'`a,r „w. s.- .Loss , Gain > ' :'Gains . , .Gain' .:. Lo-E operable: Glazing-Low-E Operable Glass, u-value 267.9 4,504 0 7,949 7,949 0.6, SHGC 0.31 Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value 58 651 0 1,328 1,328 0.4, SHGC 0.31 13A4ocs: Wall -Block, board insulation only, R-4 board 1782.7 7,137 0 3,900 3,900 insulation, open core, siding finish 16D-30: Roof/Ceiling-Under Attic with Insulation on Attic 2317 2,076 0 2,224 2,224 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Tile, Slate or Concrete, R-30 insulation 20P-11: Floor -Over open crawl space or garage, 226 494 0 176 176 Passive, R-11 blanket insulation, any cover Subtotals for structure: 14,862 0 15,577 15,577 People: 4 1,200 1,120 2,320 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 1,876 1,554 1,879 3,433 Infiltration: Winter CFM: 133, Summer CFM: 68 4,102 1,957 1,129 3,086 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: _ 0 0 1,171 1,171 System 2 AC 2 - Second Floor Load Totals: 20,840 4,711 20,876 25,587 • Supply CFM: 950 CFM Per Square ft.: 0.410 Square ft. of Room Area: 2,317 Square ft. Per Ton: 1,087 Volume (ft?) of Cond. Space: 21,618 S stemi--Loade Total Heating Required Including Ventilation Air: 20,840 Btuh 20.840 MBH { Total Sensible Gain: 20,876 Btuh 82 % Total Latent Gain: 4,711 Btuh 18 % Total Cooling Required Including Ventilation Air: 25,587 Btuh { 2.13 Tons (Based On Sensible + Latent) IN Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. S:\ ...\Stan Pac RB Laurel 5512 WBonus PSL.rh9 Tuesday, November 12, 2013, 10:14 AM