HomeMy WebLinkAboutSewage Approved3�
APPLICATION, t=AP1159312
STATE OF FLORIDA ;PERMIT # :56-SF-4529657
DEPARTMENT OF HEALTH. DOcor>ErrT #:;FI987281
ONSITE SEWAGE TREATMENT. AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION: AND.FINAL'APPROVAL DATE PAID:
FEE 'PAIDr
12ECEIPT1 #'t
APPLICANT: Standard Pacific of Florida GP' Inc..
AGENT: Dave: Fowler (Culpepper & Terpening, Inc)
PROPERTY ADDRESS: 3001 NW Radcliffe Way Port Saint Lucie, :FL 34952
LOT: :47 B OCFC::
SUBDIVISION: Riverbend xD#: 4425463-6052-000-4,
CHECKED [XI ITEMS ARE NOT IN COMPLIANCE WITH :STATUTE OR RULE AND MUST 'BE CORRECTED.,
TANK INSTALLATION
[011 TANK SIZE' [1] 900.00 12] 900.00
[921 TANK MATERIAL Concrete
[03] OUTLET DEVICE
[0'4] MULTI -CHAMBERED [ Y N ,]
[051 OUTLET FILTER POiylok PL-68
(06.1 LEGEND 1. 28-015-04DC3 2. 28-015-04DC3
(07] WATERTIGHT
(081 LEVEL
[09.1 DEPTH TO LID
DRAINFZELD INSTALLATION
[107 AREA [1], 657 [2]
['11] DISTRIBUTION BOX
NUMBER OF DRAINLINES
DRAINLINE SEPARATION
'DRAINLINE SLOPE
DEPTH OF COVER
ELEVATION [ ABCVE
SYSTEM LOCATION
DOSING -PUMPS
SQFT
HEADER X
1. 4:00 Z
BELOW ] BM 13.00
'AGGREGATE SIZE
AGGREGATE EXCESSIVE FINES
AGGREGATE DEPTH
FILL /EXCAVATION MATERIAL
[ ] 1221 PILL AMOUNT.
], [23] FILL TEXTURE.
[ ]. (24] EXCAVATION DEPTH
[ ]" [25] AREA REPLACED
I ]. (901 REPLACEMENT MATERIAL
Cbmmentsa Comments are on page 2,
CONSTRUCTION. [ APPROVED / DISAPP.ROVED ]
FINAL SYSTEM [. APPROVED / DISAPPROVED
(Explanation'of,'Violations on followi3* page)
SETBACKS
[271
SURFACE WATER
78'
FT
[281•
DITCHES
15'
FT
[29]'
PRIVATE WELLS
FT
[30]
PUBLIC WELLS
FT
[311.
IRRIGATION WELLS
FT
[321.
POTABLE WATER.
110
FT
[33]
BUILDING FOUNDATIONS
5
FT
(34],
PROPERTY LINES
10.
FT
[35`],
:OTHER
FT
FILLED:,/ MOUND SYSTEM:
[36]
DRAINFIELD COVER
[37]
SHOULDERS
1381:
SLOPES
139.1
STABILIZATION 0511'5/2015
'ADDITIONAL INFORMATION
U403 UNOBSTRUCTED AREA,
[41-] STORMWATER.RUNOFF
1423 ALARMS
1431 MAINTENANCE AGREEMENT
[441 ]BUILDING, AREA
[45;] LO.CATION" CONFORMS WITH, SITE ;PLAN
[46] FINALSITE GRADING
[AJ] CONTRACTOR Brian Davis (Brian Davis Sep
[48] OTHER INFILTRATOR QUkR4 Pius E036 LP
ABANDONMENT
[ ], [,49] TANK PUMPED
TANK CRUSHED S 'FILLED
:St. Lucie CHD DATE: 02/06/201:0
St. Lucie CHD DATE-- 05/15%20:15,
DH'4016,. 08/0.9 (Obsoletes all previous editions: which ;may not be used)
Incorporated: 64E-6.003, FAC Page 2 of .3
EH Database v 1.0.1 AP1159312 EID1529657
STATE OF FLORIDA
DEPARTMENT OF HEALTH
'0 * N , STTE SEWAGE TREATMENT 'AND DISPOSAL. -SYSTEM
CONSTRUCTION -INSPECTION AND FINAL -APPROVAL
W�s
Api-micAom #:;AP1 1159312
PERMIT #,.; 5.6-SF-I 529657
DOCUMENT t:`r1987281
DATE SAID
FEE PAID:
RECEIPT #:
Violation Number Comment
Comments
The.systern issized for 5 bedrooMr with a rn c� of 10 persons (2 per bedroom), for a total estimatedlow of
..PXImum,QccUPj@rI
20 gpd.
;Ystem Ok to cover
:ontractor bri *site
luring Final, shoulders and slopes were adequate. 'Top was,stabilized with -sod apd-tat. toast, 6" dfdover. Final will, be mailed to
ontractor.
DH 4016i ;00/00 (Obsoi-etes all previous edi:tions whidh may 'not -b6 iisedl,
Incorporated; 6413-6;00.3,, PAC Page 2. of 3
EH Database v 1.0.1 Ap1I69312 EID1529657