tnxTower Report - version 8.1.1.0
Date: August 24, 2021
Morrison Hershfield
1455 Lincoln Parkway, Suite 500
Atlanta, GA 30346
(770) 379-8500
Subject: Structural Analysis Report
Carrier Designation: Trilogy 5G, Inc Co-Locate
Site Number: FP0001
Site Name: St Lucie Blvd and Center Rd
Crown Castle Designation: BU Number: 5800245
Site Name: Fox
JDE Job Number: 683650
Work Order Number: 2010461
Order Number: 583375 Rev. 2
Engineering Firm Designation: Morrison Hershfield Project Number: CN7-925R2 / 2101398
Site Data: 5041 St. Lucie Blvd., Fort Pierce, St. Lucie County, FL 34996
Latitude 27° 28' 54.17'', Longitude -80° 22' 32.68''
134 Foot – Sabre Monopole Tower
Morrison Hershfield is pleased to submit this “Structural Analysis Report” to determine the structural integrity
of the above-mentioned tower.
The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have
determined the tower stress level for the structure and foundation, under the following load case, to be:
LC7: Proposed Equipment Configuration Sufficient Capacity
This analysis utilizes an ultimate 3-second gust wind speed of 158 mph as required by the 2020 Florida Building
Code 7th Edition. Applicable Standard references and design criteria are listed in Section 2 - Analysis Criteria.
Respectfully submitted by:
G. Lance Cooke, P.E. (FL License No. 68787)
Senior Engineer
Certificate of Authorization #8508
tnxTower Report - version 8.1.1.0
TABLE OF CONTENTS
1) INTRODUCTION
2) ANALYSIS CRITERIA
Table 1 - Proposed Equipment Configuration
Table 2 - Other Considered Equipment
3) ANALYSIS PROCEDURE
Table 3 - Documents Provided
3.1) Analysis Method
3.2) Assumptions
4) ANALYSIS RESULTS
Table 4 - Section Capacity (Summary)
Table 5 – Tower Component Stresses vs. Capacity – LC7
4.1) Recommendations
5) APPENDIX A
tnxTower Output
6) APPENDIX B
Base Level Drawing
7) APPENDIX C
Additional Calculations
August 24, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R2 / 2101398, Order 583375, Revision 2 Page 3
tnxTower Report - version 8.1.1.0
1) INTRODUCTION
This tower is a 134 ft Monopole tower designed by Sabre Communications Corporation.
2) ANALYSIS CRITERIA
TIA-222 Revision: TIA-222-H
Risk Category: II
Wind Speed: 158 mph
Exposure Category: C
Topographic Factor: 1
Service Wind Speed: 60 mph
Table 1 - Proposed Equipment Configuration
Mounting
Level (ft)
Center
Line
Elevation
(ft)
Number
of
Antennas
Antenna
Manufacturer Antenna Model
Number
of Feed
Lines
Feed
Line
Size (in)
102.0 102.0
1 - Side Arm Mount [SO 202-3] 6
3
1
1
1/4
5/8
1/8
5/16
3 ericsson Radio 4408
3 kathrein 80010922 w/ Mount Pipe
Table 2 - Other Considered Equipment
Mounting
Level (ft)
Center
Line
Elevation
(ft)
Number
of
Antennas
Antenna
Manufacturer Antenna Model
Number
of Feed
Lines
Feed
Line
Size (in)
132.0
133.0
6 ericsson RRUS 11 B12
15
3
2
1
1-5/8
5/16
3/4
3/8
6 ericsson RRUS 11 B2
3 ericsson TME-RRUS 11
6 kathrein 800 10122 w/ Mount Pipe
3 kathrein 800 10764 w/ Mount Pipe
132.0
1 - Platform Mount [LP 303-1]
3 andrew CBC819-DF
6 andrew ETB19G8-12UB
1 raycap DC6-48-60-18-8F
120.0 123.0
3 commscope FFHH-65C-R3 w/ Mount Pipe
12 1-5/8
3 ericsson AIR6449 B41_T-MOBILE w/
Mount Pipe
3 ericsson RADIO 4460 B2/B25 B66_TMO
3 ericsson RADIO 4480 B71_TMO
120.0 1 - Platform Mount [LP 303-1_HR-1]
112.0 112.0
1 - Commscope MC-PK8-DSH
1 1-1/2
3 fujitsu TA08025-B604
3 fujitsu TA08025-B605
3 jma wireless MX08FRO665-21 w/ Mount Pipe
1 raycap RDIDC-9181-PF-48
August 24, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R2 / 2101398, Order 583375, Revision 2 Page 4
tnxTower Report - version 8.1.1.0
3) ANALYSIS PROCEDURE
Table 3 - Documents Provided
Document Reference Source
4-GEOTECHNICAL REPORTS 2609348 CCISITES
4-TOWER FOUNDATION
DRAWINGS/DESIGN/SPECS 2604744 CCISITES
4-TOWER MANUFACTURER DRAWINGS 2604731 CCISITES
3.1) Analysis Method
tnxTower (version 8.1.1.0), a commercially available analysis software package, was used to create a
three-dimensional model of the tower and calculate member stresses for various loading cases.
Selected output from the analysis is included in Appendix A. When applicable, Crown Castle has
calculated and provided the effective area for panel antennas using approved methods following the
intent of the TIA-222 standard.
3.2) Assumptions
1) Tower and structures were maintained in accordance with the TIA-222 Standard.
2) The configuration of antennas, transmission cables, mounts and other appurtenances are as
specified in Tables 1 and 2 and the referenced drawings.
This analysis may be affected if any assumptions are not valid or have been made in error. Morrison
Hershfield should be notified to determine the effect on the structural integrity of the tower.
4) ANALYSIS RESULTS
Table 4 - Section Capacity (Summary)
Section
No. Elevation (ft) Component Type Size Critical
Element P (K) SF*P_allow
(K) %
Capacity Pass / Fail
L1 134 - 96.75 Pole TP27.77x16x0.25 1 -12.58 1279.74 64.7 Pass
L2 96.75 - 47.25 Pole TP42.91x26.0061x0.5 2 -25.48 3949.39 46.7 Pass
L3 47.25 - 0 Pole TP56.84x40.0142x0.5 3 -46.39 5492.11 51.4 Pass
Summary
Pole (L1) 64.7 Pass
Rating = 64.7 Pass
Table 5 - Tower Component Stresses vs. Capacity – LC7
Notes Component Elevation (ft) % Capacity Pass / Fail
1 Anchor Rods 0 47.1 Pass
1 Base Plate 0 32.4 Pass
1 Base Foundation (Structure) 0 53.9 Pass
1 Base Foundation (Soil Interaction) 0 21.3 Pass
Structure Rating (max from all components) = 64.7%
Notes:
1) See additional documentation in “Appendix C – Additional Calculations” for calculations supporting the % capacity
consumed.
2) Rating per TIA-222-H, Section 15.5.
August 24, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R2 / 2101398, Order 583375, Revision 2 Page 5
tnxTower Report - version 8.1.1.0
4.1) Recommendations
The tower and its foundation have sufficient capacity to carry the proposed load configuration. No
modifications are required at this time.
tnxTower Report - version 8.1.1.0
APPENDIX A
TNXTOWER OUTPUT
Consulting Engineers
Morrison Hershfield
1455 Lincoln Parkway, Suite 500
Atlanta, GA 30346
Phone: (770) 379-8500
FAX: (770) 379-8501
Job: CN7-925R2 / 2101398
Project: 5800245 / FOX
Client: Crown Castle USA Drawn by: MK App'd:
Code: TIA-222-H Date: 08/24/21 Scale: NTS
Path:
C:\Users\mkodey\Documents\Madhuri (WORK)\Reviews\CN7-925\CN7-925R2 SA\Analysis\CN7-925R2 BU_5800245 WO_2010461.eri
Dwg No. E-1
134.0 ft
96.8 ft
47.3 ft
0.0 ft
REACTIONS - 158 mph WIND
TORQUE 2 kip-ft
41 K
SHEAR
3894 kip-ft
MOMENT
46 K
AXIAL
ARE FACTORED
ALL REACTIONS
Section 123 Length (ft) 37.2553.5053.25 Number of Sides 181818 Thickness (in) 0.25000.50000.5000 Socket Length (ft) 4.006.00 Top Dia (in) 16.000026.006140.0142 Bot Dia (in) 27.770042.910056.8400 Grade A572-65 Weight (K) 2.29.813.825.8MATERIAL STRENGTH
GRADE GRADEFy FyFu Fu
A572-65 65 ksi 80 ksi
TOWER DESIGN NOTES
1. Tower designed for Exposure C to the TIA-222-H Standard.
2. Tower designed for a 158 mph basic wind in accordance with the TIA-222-H Standard.
3. Deflections are based upon a 60 mph wind.
4. Tower Risk Category II.
5. Topographic Category 1 with Crest Height of 0.00 ft
6. TOWER RATING: 64.7%
August 24, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R2 / 2101398, Order 583375, Revision 2 Page 7
tnxTower Report - version 8.1.1.0
Tower Input Data
The tower is a monopole.
This tower is designed using the TIA-222-H standard.
The following design criteria apply:
Tower base elevation above sea level: 19.00 ft.
Basic wind speed of 158 mph.
Risk Category II.
Exposure Category C.
Simplified Topographic Factor Procedure for wind speed-up calculations is used.
Topographic Category: 1.
Crest Height: 0.00 ft.
Deflections calculated using a wind speed of 60 mph.
A non-linear (P-delta) analysis was used.
Pressures are calculated at each section.
Stress ratio used in pole design is 1.
Tower analysis based on target reliabilities in accordance with Annex S.
Load Modification Factors used: Kes(Fw) = 0.95.
Maximum demand-capacity ratio is: 1.05.
Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not
considered.
Options
Consider Moments - Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules
Consider Moments - Horizontals Assume Legs Pinned Calculate Redundant Bracing Forces
Consider Moments - Diagonals √ Assume Rigid Index Plate Ignore Redundant Members in FEA
Use Moment Magnification √ Use Clear Spans For Wind Area SR Leg Bolts Resist Compression
√ Use Code Stress Ratios Use Clear Spans For KL/r All Leg Panels Have Same Allowable
√ Use Code Safety Factors - Guys Retension Guys To Initial Tension Offset Girt At Foundation
Escalate Ice √ Bypass Mast Stability Checks √ Consider Feed Line Torque
Always Use Max Kz √ Use Azimuth Dish Coefficients Include Angle Block Shear Check
Use Special Wind Profile √ Project Wind Area of Appurt. Use TIA-222-H Bracing Resist. Exemption
Include Bolts In Member Capacity Autocalc Torque Arm Areas Use TIA-222-H Tension Splice Exemption
Leg Bolts Are At Top Of Section Add IBC .6D+W Combination Poles
Secondary Horizontal Braces Leg Sort Capacity Reports By Component √ Include Shear-Torsion Interaction
Use Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow
SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets
SR Members Are Concentric Ignore KL/ry For 60 Deg. Angle Legs Pole Without Linear Attachments
Pole With Shroud Or No Appurtenances
Outside and Inside Corner Radii Are Known
Tapered Pole Section Geometry
Section Elevation
ft
Section
Length
ft
Splice
Length
ft
Number
of
Sides
Top
Diameter
in
Bottom
Diameter
in
Wall
Thickness
in
Bend
Radius
in
Pole Grade
L1 134.00-96.75 37.25 4.00 18 16.0000 27.7700 0.2500 1.0000 A572-65
(65 ksi)
L2 96.75-47.25 53.50 6.00 18 26.0061 42.9100 0.5000 2.0000 A572-65
(65 ksi)
L3 47.25-0.00 53.25 18 40.0142 56.8400 0.5000 2.0000 A572-65
(65 ksi)
August 24, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R2 / 2101398, Order 583375, Revision 2 Page 8
tnxTower Report - version 8.1.1.0
Tapered Pole Properties
Section Tip Dia.
in
Area
in2
I
in4
r
in
C
in
I/C
in3
J
in4
It/Q
in2
w
in
w/t
L1 16.2083 12.4976 391.6752 5.5912 8.1280 48.1884 783.8657 6.2500 2.3760 9.504
28.1598 21.8371 2089.4389 9.7696 14.1072 148.1119 4181.6271 10.9206 4.4475 17.79
L2 27.6135 40.4782 3326.9550 9.0547 13.2111 251.8302 6658.2877 20.2429 3.6971 7.394
43.4948 67.3047 15293.933
4
15.0556 21.7983 701.6119 30607.9909 33.6587 6.6722 13.344
L3 42.4795 62.7091 12370.155
4
14.0276 20.3272 608.5509 24756.5878 31.3605 6.1625 12.325
57.6397 89.4116 35856.253
1
20.0007 28.8747 1241.7870 71759.6868 44.7143 9.1238 18.248
Tower
Elevation
ft
Gusset
Area
(per face)
ft2
Gusset
Thickness
in
Gusset Grade Adjust. Factor
Af
Adjust.
Factor
Ar
Weight Mult.
Double Angle
Stitch Bolt
Spacing
Diagonals
in
Double Angle
Stitch Bolt
Spacing
Horizontals
in
Double Angle
Stitch Bolt
Spacing
Redundants
in
L1 134.00-
96.75
1 1 1
L2 96.75-
47.25
1 1 1
L3 47.25-0.00 1 1 1
Feed Line/Linear Appurtenances - Entered As Round Or Flat
Description Sector Exclude
From
Torque
Calculation
Componen
t
Type
Placement
ft
Total
Number
Number
Per Row
Start/En
d
Position
Width or
Diamete
r
in
Perimete
r
in
Weight
plf
****
Safety Line 3/8 C No Surface Ar
(CaAa)
134.00 -
10.00
1 1 0.000
0.000
0.3750 0.22
Climbing Pegs C No Surface Ar
(CaAa)
134.00 -
10.00
1 1 -0.050
0.050
0.7050 1.80
*******
RPM1191647(5/8) C No Surface Ar
(CaAa)
102.00 -
8.00
3 3 -0.260
-0.240
0.6290 0.14
RPM2533512(1/8) C No Surface Ar
(CaAa)
102.00 -
8.00
1 1 -0.320
-0.310
0.1880 0.02
TFL90134(1/4) C No Surface Ar
(CaAa)
102.00 -
8.00
3 3 -0.310
-0.290
0.3280 0.00
860 10009(1/4) C No Surface Ar
(CaAa)
102.00 -
8.00
3 3 -0.290
-0.260
0.3140 0.00
860 10013(5/16) C No Surface Ar
(CaAa)
102.00 -
8.00
1 1 -0.270
-0.260
0.3100 0.00
Feed Line/Linear Appurtenances - Entered As Area
Description Face
or
Leg
Allow
Shield
Exclude
From
Torque
Calculation
Componen
t
Type
Placement
ft
Total
Number
CAAA
ft2/ft
Weight
plf
******
LDF7-50A(1-5/8) A No No Inside Pole 132.00 - 8.00 15 No Ice 0.00 0.82
840 10414(5/16) A No No Inside Pole 132.00 - 8.00 3 No Ice 0.00 0.06
12 PAIR(3/8) A No No Inside Pole 132.00 - 8.00 1 No Ice 0.00 0.08
WR-VG86ST-
BRD(3/4)
A No No Inside Pole 132.00 - 8.00 2 No Ice 0.00 0.58
******
EC7-50A(1-5/8) C No No Inside Pole 120.00 - 3.00 10 No Ice 0.00 0.68
***
August 24, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R2 / 2101398, Order 583375, Revision 2 Page 9
tnxTower Report - version 8.1.1.0
Description Face
or
Leg
Allow
Shield
Exclude
From
Torque
Calculation
Componen
t
Type
Placement
ft
Total
Number
CAAA
ft2/ft
Weight
plf
HB158-21U6S24-
xxM_TMO(1-5/8)
C No No Inside Pole 120.00 - 3.00 2 No Ice 0.00 2.50
*****
CU12PSM9P6XXX
(1-1/2)
B No No Inside Pole 112.00 - 3.00 1 No Ice 0.00 2.35
Feed Line/Linear Appurtenances Section Areas
Tower
Sectio
n
Tower
Elevation
ft
Face AR
ft2
AF
ft2
CAAA
In Face
ft2
CAAA
Out Face
ft2
Weight
K
L1 134.00-96.75 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
6.286
0.000
0.000
0.000
0.48
0.04
0.35
L2 96.75-47.25 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
26.685
0.000
0.000
0.000
0.68
0.12
0.71
L3 47.25-0.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
20.944
0.000
0.000
0.000
0.54
0.10
0.61
Feed Line Center of Pressure
Section Elevation
ft
CPX
in
CPZ
in
CPX
Ice
in
CPZ
Ice
in
L1 134.00-96.75 0.2940 1.2612 0.1870 0.8022
L2 96.75-47.25 1.5211 3.1022 1.0038 2.0471
L3 47.25-0.00 1.3373 2.6907 0.8561 1.7226
Note: For pole sections, center of pressure calculations do not consider feed line shielding.
Shielding Factor Ka
Tower
Section
Feed Line
Record No.
Description Feed Line
Segment Elev.
Ka
No Ice
Ka
Ice
L1 2 Safety Line 3/8 96.75 - 134.00 1.0000 1.0000
L1 3 Climbing Pegs 96.75 - 134.00 1.0000 1.0000
L1 18 RPM1191647(5/8) 96.75 - 102.00 1.0000 1.0000
L1 19 RPM2533512(1/8) 96.75 - 102.00 1.0000 1.0000
L1 20 TFL90134(1/4) 96.75 - 102.00 1.0000 1.0000
L1 21 860 10009(1/4) 96.75 - 102.00 1.0000 1.0000
L1 22 860 10013(5/16) 96.75 - 102.00 1.0000 1.0000
L2 2 Safety Line 3/8 47.25 - 96.75 1.0000 1.0000
L2 3 Climbing Pegs 47.25 - 96.75 1.0000 1.0000
L2 18 RPM1191647(5/8) 47.25 - 96.75 1.0000 1.0000
L2 19 RPM2533512(1/8) 47.25 - 96.75 1.0000 1.0000
L2 20 TFL90134(1/4) 47.25 - 96.75 1.0000 1.0000
L2 21 860 10009(1/4) 47.25 - 96.75 1.0000 1.0000
L2 22 860 10013(5/16) 47.25 - 96.75 1.0000 1.0000
L3 2 Safety Line 3/8 10.00 - 47.25 1.0000 1.0000
L3 3 Climbing Pegs 10.00 - 47.25 1.0000 1.0000
L3 18 RPM1191647(5/8) 8.00 - 47.25 1.0000 1.0000
L3 19 RPM2533512(1/8) 8.00 - 47.25 1.0000 1.0000
L3 20 TFL90134(1/4) 8.00 - 47.25 1.0000 1.0000
L3 21 860 10009(1/4) 8.00 - 47.25 1.0000 1.0000
L3 22 860 10013(5/16) 8.00 - 47.25 1.0000 1.0000
August 24, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R2 / 2101398, Order 583375, Revision 2 Page 10
tnxTower Report - version 8.1.1.0
Discrete Tower Loads
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustmen
t
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
K
Lighting Rod 3/4'' x 3' C From Leg 0.00
0.00
1.50
0.0000 134.00 No Ice 0.23 0.23 0.03
*******
(2) 800 10122 w/ Mount
Pipe
A From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 6.24 4.89 0.09
(2) 800 10122 w/ Mount
Pipe
B From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 6.24 4.89 0.09
(2) 800 10122 w/ Mount
Pipe
C From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 6.24 4.89 0.09
800 10764 w/ Mount Pipe A From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 4.33 3.12 0.07
800 10764 w/ Mount Pipe B From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 4.33 3.12 0.07
800 10764 w/ Mount Pipe B From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 4.33 3.12 0.07
TME-RRUS 11 A From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 2.79 1.19 0.05
TME-RRUS 11 B From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 2.79 1.19 0.05
TME-RRUS 11 C From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 2.79 1.19 0.05
(2) RRUS 11 B12 A From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 2.83 1.18 0.05
(2) RRUS 11 B12 B From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 2.83 1.18 0.05
(2) RRUS 11 B12 C From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 2.83 1.18 0.05
(2) RRUS 11 B2 A From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 2.83 1.18 0.05
(2) RRUS 11 B2 B From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 2.83 1.18 0.05
(2) RRUS 11 B2 C From Leg 4.00
0.00
1.00
0.0000 132.00 No Ice 2.83 1.18 0.05
CBC819-DF A From Leg 4.00
0.00
0.00
0.0000 132.00 No Ice 0.45 0.07 0.00
CBC819-DF B From Leg 4.00
0.00
0.00
0.0000 132.00 No Ice 0.45 0.07 0.00
CBC819-DF C From Leg 4.00
0.00
0.00
0.0000 132.00 No Ice 0.45 0.07 0.00
(2) ETB19G8-12UB A From Leg 4.00
0.00
0.00
0.0000 132.00 No Ice 0.91 0.42 0.02
August 24, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R2 / 2101398, Order 583375, Revision 2 Page 11
tnxTower Report - version 8.1.1.0
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustmen
t
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
K
(2) ETB19G8-12UB B From Leg 4.00
0.00
0.00
0.0000 132.00 No Ice 0.91 0.42 0.02
(2) ETB19G8-12UB C From Leg 4.00
0.00
0.00
0.0000 132.00 No Ice 0.91 0.42 0.02
DC6-48-60-18-8F B From Leg 4.00
0.00
0.00
0.0000 132.00 No Ice 0.92 0.92 0.02
8' x 2'' Mount Pipe A From Leg 4.00
0.00
0.00
0.0000 132.00 No Ice 1.90 1.90 0.03
8' x 2'' Mount Pipe B From Leg 4.00
0.00
0.00
0.0000 132.00 No Ice 1.90 1.90 0.03
8' x 2'' Mount Pipe C From Leg 4.00
0.00
0.00
0.0000 132.00 No Ice 1.90 1.90 0.03
Platform Mount [LP 303-1] B None 0.0000 132.00 No Ice 14.69 14.69 1.25
******
(2) 8' x 2'' Mount Pipe A From Leg 4.00
0.00
0.00
0.0000 120.00 No Ice 1.90 1.90 0.03
(2) 8' x 2'' Mount Pipe B From Leg 4.00
0.00
0.00
0.0000 120.00 No Ice 1.90 1.90 0.03
(2) 8' x 2'' Mount Pipe C From Leg 4.00
0.00
0.00
0.0000 120.00 No Ice 1.90 1.90 0.03
Platform Mount [LP 303-
1_HR-1]
A None 0.0000 120.00 No Ice 17.09 17.09 1.50
****
FFHH-65C-R3 w/ Mount
Pipe
A From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 12.97 6.20 0.16
FFHH-65C-R3 w/ Mount
Pipe
B From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 12.97 6.20 0.16
FFHH-65C-R3 w/ Mount
Pipe
C From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 12.97 6.20 0.16
AIR6449 B41_T-MOBILE
w/ Mount Pipe
A From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 5.19 2.71 0.13
AIR6449 B41_T-MOBILE
w/ Mount Pipe
B From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 5.19 2.71 0.13
AIR6449 B41_T-MOBILE
w/ Mount Pipe
C From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 5.19 2.71 0.13
RADIO 4460 B2/B25
B66_TMO
A From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 2.14 1.69 0.11
RADIO 4460 B2/B25
B66_TMO
B From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 2.14 1.69 0.11
RADIO 4460 B2/B25
B66_TMO
C From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 2.14 1.69 0.11
RADIO 4480 B71_TMO A From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 2.85 1.38 0.09
RADIO 4480 B71_TMO B From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 2.85 1.38 0.09
August 24, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R2 / 2101398, Order 583375, Revision 2 Page 12
tnxTower Report - version 8.1.1.0
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustmen
t
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
K
RADIO 4480 B71_TMO C From Leg 4.00
0.00
3.00
0.0000 120.00 No Ice 2.85 1.38 0.09
******
MX08FRO665-21 w/
Mount Pipe
A From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 8.01 4.23 0.11
MX08FRO665-21 w/
Mount Pipe
B From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 8.01 4.23 0.11
MX08FRO665-21 w/
Mount Pipe
C From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 8.01 4.23 0.11
TA08025-B605 A From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.96 1.13 0.08
TA08025-B605 B From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.96 1.13 0.08
TA08025-B605 C From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.96 1.13 0.08
TA08025-B604 A From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.96 0.98 0.06
TA08025-B604 B From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.96 0.98 0.06
TA08025-B604 C From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.96 0.98 0.06
RDIDC-9181-PF-48 A From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 2.01 1.17 0.02
(2) 8' x 2'' Mount Pipe A From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.90 1.90 0.03
(2) 8' x 2'' Mount Pipe B From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.90 1.90 0.03
(2) 8' x 2'' Mount Pipe C From Leg 4.00
0.00
0.00
0.0000 112.00 No Ice 1.90 1.90 0.03
Commscope MC-PK8-DSH A None 0.0000 112.00 No Ice 34.24 34.24 1.75
******
80010922 w/ Mount Pipe A From Leg 2.00
0.00
0.00
0.0000 102.00 No Ice 1.61 1.27 0.03
80010922 w/ Mount Pipe B From Leg 2.00
0.00
0.00
0.0000 102.00 No Ice 1.61 1.27 0.03
80010922 w/ Mount Pipe C From Leg 2.00
0.00
0.00
0.0000 102.00 No Ice 1.61 1.27 0.03
Radio 4408 A From Leg 2.00
0.00
0.00
0.0000 102.00 No Ice 0.60 0.33 0.01
Radio 4408 B From Leg 2.00
0.00
0.00
0.0000 102.00 No Ice 0.60 0.33 0.01
Radio 4408 C From Leg 2.00
0.00
0.00
0.0000 102.00 No Ice 0.60 0.33 0.01
Side Arm Mount [SO 202-
3]
A None 0.0000 102.00 No Ice 5.70 5.70 0.33
August 24, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R2 / 2101398, Order 583375, Revision 2 Page 13
tnxTower Report - version 8.1.1.0
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustmen
t
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
K
***
Load Combinations
Comb.
No.
Description
1 Dead Only
2 1.2 Dead+1.0 Wind 0 deg - No Ice
3 0.9 Dead+1.0 Wind 0 deg - No Ice
4 1.2 Dead+1.0 Wind 30 deg - No Ice
5 0.9 Dead+1.0 Wind 30 deg - No Ice
6 1.2 Dead+1.0 Wind 60 deg - No Ice
7 0.9 Dead+1.0 Wind 60 deg - No Ice
8 1.2 Dead+1.0 Wind 90 deg - No Ice
9 0.9 Dead+1.0 Wind 90 deg - No Ice
10 1.2 Dead+1.0 Wind 120 deg - No Ice
11 0.9 Dead+1.0 Wind 120 deg - No Ice
12 1.2 Dead+1.0 Wind 150 deg - No Ice
13 0.9 Dead+1.0 Wind 150 deg - No Ice
14 1.2 Dead+1.0 Wind 180 deg - No Ice
15 0.9 Dead+1.0 Wind 180 deg - No Ice
16 1.2 Dead+1.0 Wind 210 deg - No Ice
17 0.9 Dead+1.0 Wind 210 deg - No Ice
18 1.2 Dead+1.0 Wind 240 deg - No Ice
19 0.9 Dead+1.0 Wind 240 deg - No Ice
20 1.2 Dead+1.0 Wind 270 deg - No Ice
21 0.9 Dead+1.0 Wind 270 deg - No Ice
22 1.2 Dead+1.0 Wind 300 deg - No Ice
23 0.9 Dead+1.0 Wind 300 deg - No Ice
24 1.2 Dead+1.0 Wind 330 deg - No Ice
25 0.9 Dead+1.0 Wind 330 deg - No Ice
26 Dead+Wind 0 deg - Service
27 Dead+Wind 30 deg - Service
28 Dead+Wind 60 deg - Service
29 Dead+Wind 90 deg - Service
30 Dead+Wind 120 deg - Service
31 Dead+Wind 150 deg - Service
32 Dead+Wind 180 deg - Service
33 Dead+Wind 210 deg - Service
34 Dead+Wind 240 deg - Service
35 Dead+Wind 270 deg - Service
36 Dead+Wind 300 deg - Service
37 Dead+Wind 330 deg - Service
Maximum Member Forces
Sectio
n
No.
Elevation
ft
Component
Type
Condition Gov.
Load
Comb.
Axial
K
Major Axis
Moment
kip-ft
Minor Axis
Moment
kip-ft
L1 134 - 96.75 Pole Max Tension 1 0.00 0.00 0.00
Max. Compression 18 -12.61 462.16 -265.84
Max. Mx 8 -12.60 -536.90 -3.01
Max. My 14 -12.59 -3.61 -536.85
Max. Vy 8 25.31 -536.90 -3.01
Max. Vx 14 25.37 -3.61 -536.85
Max. Torque 2 -2.47
L2 96.75 -
47.25
Pole Max Tension 1 0.00 0.00 0.00
Max. Compression 18 -25.49 1644.99 -947.82
August 24, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R2 / 2101398, Order 583375, Revision 2 Page 14
tnxTower Report - version 8.1.1.0
Sectio
n
No.
Elevation
ft
Component
Type
Condition Gov.
Load
Comb.
Axial
K
Major Axis
Moment
kip-ft
Minor Axis
Moment
kip-ft
Max. Mx 8 -25.48 -1905.31 -7.62
Max. My 14 -25.48 -8.11 -1908.15
Max. Vy 8 32.61 -1905.31 -7.62
Max. Vx 14 32.67 -8.11 -1908.15
Max. Torque 2 -2.47
L3 47.25 - 0 Pole Max Tension 1 0.00 0.00 0.00
Max. Compression 18 -46.39 3351.62 -1932.10
Max. Mx 8 -46.39 -3878.77 -12.72
Max. My 14 -46.39 -12.97 -3884.86
Max. Vy 8 41.35 -3878.77 -12.72
Max. Vx 14 41.41 -12.97 -3884.86
Max. Torque 2 -2.46
Maximum Reactions
Location Condition Gov.
Load
Comb.
Vertical
K
Horizontal, X
K
Horizontal, Z
K
Pole Max. Vert 14 46.42 -0.09 -41.38
Max. Hx 20 46.42 41.32 0.09
Max. Hz 2 46.42 0.09 41.38
Max. Mx 2 3883.88 0.09 41.38
Max. Mz 8 3878.77 -41.32 -0.09
Max. Torsion 14 2.45 -0.09 -41.38
Min. Vert 7 34.81 -35.74 20.61
Min. Hx 8 46.42 -41.32 -0.09
Min. Hz 14 46.42 -0.09 -41.38
Min. Mx 14 -3884.86 -0.09 -41.38
Min. Mz 20 -3877.26 41.32 0.09
Min. Torsion 2 -2.46 0.09 41.38
Tower Mast Reaction Summary
Load
Combination
Vertical
K
Shearx
K
Shearz
K
Overturning
Moment, Mx
kip-ft
Overturning
Moment, Mz
kip-ft
Torque
kip-ft
Dead Only 38.68 0.00 0.00 0.40 -0.60 0.00
1.2 Dead+1.0 Wind 0 deg -
No Ice
46.42 -0.09 -41.38 -3883.88 11.48 2.46
0.9 Dead+1.0 Wind 0 deg -
No Ice
34.81 -0.09 -41.38 -3859.12 11.58 2.45
1.2 Dead+1.0 Wind 30 deg -
No Ice
46.42 20.58 -35.79 -3357.39 -1929.17 2.04
0.9 Dead+1.0 Wind 30 deg -
No Ice
34.81 20.58 -35.79 -3336.01 -1916.64 2.03
1.2 Dead+1.0 Wind 60 deg -
No Ice
46.42 35.74 -20.61 -1931.13 -3353.12 1.07
0.9 Dead+1.0 Wind 60 deg -
No Ice
34.81 35.74 -20.61 -1918.89 -3331.45 1.06
1.2 Dead+1.0 Wind 90 deg -
No Ice
46.42 41.32 0.09 12.72 -3878.77 -0.19
0.9 Dead+1.0 Wind 90 deg -
No Ice
34.81 41.32 0.09 12.50 -3853.72 -0.19
1.2 Dead+1.0 Wind 120 deg
- No Ice
46.42 35.83 20.77 1953.26 -3365.30 -1.39
0.9 Dead+1.0 Wind 120 deg
- No Ice
34.81 35.83 20.77 1940.61 -3343.54 -1.39
1.2 Dead+1.0 Wind 150 deg
- No Ice
46.42 20.74 35.88 3370.55 -1950.32 -2.22
0.9 Dead+1.0 Wind 150 deg
- No Ice
34.81 20.74 35.88 3348.83 -1937.62 -2.21
August 24, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R2 / 2101398, Order 583375, Revision 2 Page 15
tnxTower Report - version 8.1.1.0
Load
Combination
Vertical
K
Shearx
K
Shearz
K
Overturning
Moment, Mx
kip-ft
Overturning
Moment, Mz
kip-ft
Torque
kip-ft
1.2 Dead+1.0 Wind 180 deg
- No Ice
46.42 0.09 41.38 3884.86 -12.97 -2.45
0.9 Dead+1.0 Wind 180 deg
- No Ice
34.81 0.09 41.38 3859.85 -12.68 -2.45
1.2 Dead+1.0 Wind 210 deg
- No Ice
46.42 -20.58 35.79 3358.37 1927.68 -2.03
0.9 Dead+1.0 Wind 210 deg
- No Ice
34.81 -20.58 35.79 3336.73 1915.54 -2.03
1.2 Dead+1.0 Wind 240 deg
- No Ice
46.42 -35.74 20.61 1932.10 3351.62 -1.07
0.9 Dead+1.0 Wind 240 deg
- No Ice
34.81 -35.74 20.61 1919.62 3330.34 -1.07
1.2 Dead+1.0 Wind 270 deg
- No Ice
46.42 -41.32 -0.09 -11.73 3877.26 0.18
0.9 Dead+1.0 Wind 270 deg
- No Ice
34.81 -41.32 -0.09 -11.76 3852.61 0.18
1.2 Dead+1.0 Wind 300 deg
- No Ice
46.42 -35.83 -20.77 -1952.27 3363.80 1.38
0.9 Dead+1.0 Wind 300 deg
- No Ice
34.81 -35.83 -20.77 -1939.87 3342.43 1.38
1.2 Dead+1.0 Wind 330 deg
- No Ice
46.42 -20.74 -35.88 -3369.56 1948.83 2.22
0.9 Dead+1.0 Wind 330 deg
- No Ice
34.81 -20.74 -35.88 -3348.09 1936.52 2.22
Dead+Wind 0 deg - Service 38.68 -0.01 -5.62 -525.57 1.03 0.34
Dead+Wind 30 deg - Service 38.68 2.80 -4.86 -454.27 -261.75 0.28
Dead+Wind 60 deg - Service 38.68 4.86 -2.80 -261.15 -454.56 0.15
Dead+Wind 90 deg - Service 38.68 5.61 0.01 2.06 -525.74 -0.02
Dead+Wind 120 deg -
Service
38.68 4.87 2.82 264.83 -456.22 -0.19
Dead+Wind 150 deg -
Service
38.68 2.82 4.87 456.74 -264.62 -0.31
Dead+Wind 180 deg -
Service
38.68 0.01 5.62 526.38 -2.28 -0.34
Dead+Wind 210 deg -
Service
38.68 -2.80 4.86 455.09 260.50 -0.28
Dead+Wind 240 deg -
Service
38.68 -4.86 2.80 261.96 453.31 -0.15
Dead+Wind 270 deg -
Service
38.68 -5.61 -0.01 -1.25 524.49 0.02
Dead+Wind 300 deg -
Service
38.68 -4.87 -2.82 -264.01 454.96 0.19
Dead+Wind 330 deg -
Service
38.68 -2.82 -4.87 -455.93 263.36 0.31
Solution Summary
Load
Comb.
Sum of Applied Forces Sum of Reactions
% Error PX
K
PY
K
PZ
K
PX
K
PY
K
PZ
K
1 0.00 -38.68 0.00 0.00 38.68 0.00 0.000%
2 -0.09 -46.42 -41.38 0.09 46.42 41.38 0.000%
3 -0.09 -34.81 -41.38 0.09 34.81 41.38 0.000%
4 20.58 -46.42 -35.79 -20.58 46.42 35.79 0.000%
5 20.58 -34.81 -35.79 -20.58 34.81 35.79 0.000%
6 35.74 -46.42 -20.61 -35.74 46.42 20.61 0.000%
7 35.74 -34.81 -20.61 -35.74 34.81 20.61 0.000%
8 41.32 -46.42 0.09 -41.32 46.42 -0.09 0.000%
9 41.32 -34.81 0.09 -41.32 34.81 -0.09 0.000%
10 35.83 -46.42 20.77 -35.83 46.42 -20.77 0.000%
11 35.83 -34.81 20.77 -35.83 34.81 -20.77 0.000%
12 20.74 -46.42 35.88 -20.74 46.42 -35.88 0.000%
13 20.74 -34.81 35.88 -20.74 34.81 -35.88 0.000%
14 0.09 -46.42 41.38 -0.09 46.42 -41.38 0.000%
15 0.09 -34.81 41.38 -0.09 34.81 -41.38 0.000%
16 -20.58 -46.42 35.79 20.58 46.42 -35.79 0.000%
August 24, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R2 / 2101398, Order 583375, Revision 2 Page 16
tnxTower Report - version 8.1.1.0
Load
Comb.
Sum of Applied Forces Sum of Reactions
% Error PX
K
PY
K
PZ
K
PX
K
PY
K
PZ
K
17 -20.58 -34.81 35.79 20.58 34.81 -35.79 0.000%
18 -35.74 -46.42 20.61 35.74 46.42 -20.61 0.000%
19 -35.74 -34.81 20.61 35.74 34.81 -20.61 0.000%
20 -41.32 -46.42 -0.09 41.32 46.42 0.09 0.000%
21 -41.32 -34.81 -0.09 41.32 34.81 0.09 0.000%
22 -35.83 -46.42 -20.77 35.83 46.42 20.77 0.000%
23 -35.83 -34.81 -20.77 35.83 34.81 20.77 0.000%
24 -20.74 -46.42 -35.88 20.74 46.42 35.88 0.000%
25 -20.74 -34.81 -35.88 20.74 34.81 35.88 0.000%
26 -0.01 -38.68 -5.62 0.01 38.68 5.62 0.000%
27 2.80 -38.68 -4.86 -2.80 38.68 4.86 0.000%
28 4.86 -38.68 -2.80 -4.86 38.68 2.80 0.000%
29 5.61 -38.68 0.01 -5.61 38.68 -0.01 0.000%
30 4.87 -38.68 2.82 -4.87 38.68 -2.82 0.000%
31 2.82 -38.68 4.87 -2.82 38.68 -4.87 0.000%
32 0.01 -38.68 5.62 -0.01 38.68 -5.62 0.000%
33 -2.80 -38.68 4.86 2.80 38.68 -4.86 0.000%
34 -4.86 -38.68 2.80 4.86 38.68 -2.80 0.000%
35 -5.61 -38.68 -0.01 5.61 38.68 0.01 0.000%
36 -4.87 -38.68 -2.82 4.87 38.68 2.82 0.000%
37 -2.82 -38.68 -4.87 2.82 38.68 4.87 0.000%
Non-Linear Convergence Results
Load
Combination
Converged? Number
of Cycles
Displacement
Tolerance
Force
Tolerance
1 Yes 4 0.00000001 0.00000001
2 Yes 4 0.00000001 0.00035105
3 Yes 4 0.00000001 0.00021012
4 Yes 5 0.00000001 0.00011080
5 Yes 5 0.00000001 0.00004545
6 Yes 5 0.00000001 0.00010204
7 Yes 5 0.00000001 0.00004142
8 Yes 4 0.00000001 0.00003646
9 Yes 4 0.00000001 0.00001777
10 Yes 5 0.00000001 0.00010320
11 Yes 5 0.00000001 0.00004170
12 Yes 5 0.00000001 0.00011265
13 Yes 5 0.00000001 0.00004605
14 Yes 4 0.00000001 0.00041611
15 Yes 4 0.00000001 0.00024862
16 Yes 5 0.00000001 0.00009972
17 Yes 5 0.00000001 0.00004039
18 Yes 5 0.00000001 0.00010787
19 Yes 5 0.00000001 0.00004413
20 Yes 4 0.00000001 0.00005781
21 Yes 4 0.00000001 0.00003260
22 Yes 5 0.00000001 0.00010986
23 Yes 5 0.00000001 0.00004482
24 Yes 5 0.00000001 0.00010103
25 Yes 5 0.00000001 0.00004075
26 Yes 4 0.00000001 0.00001079
27 Yes 4 0.00000001 0.00002094
28 Yes 4 0.00000001 0.00001457
29 Yes 4 0.00000001 0.00000001
30 Yes 4 0.00000001 0.00001489
31 Yes 4 0.00000001 0.00002158
32 Yes 4 0.00000001 0.00001102
33 Yes 4 0.00000001 0.00001438
34 Yes 4 0.00000001 0.00001815
35 Yes 4 0.00000001 0.00000001
36 Yes 4 0.00000001 0.00001881
37 Yes 4 0.00000001 0.00001471
August 24, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R2 / 2101398, Order 583375, Revision 2 Page 17
tnxTower Report - version 8.1.1.0
Maximum Tower Deflections - Service Wind
Section
No.
Elevation
ft
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
°
Twist
°
L1 134 - 96.75 10.024 30 0.7637 0.0056
L2 100.75 - 47.25 5.283 31 0.5341 0.0012
L3 53.25 - 0 1.388 31 0.2484 0.0003
Critical Deflections and Radius of Curvature - Service Wind
Elevation
ft
Appurtenance Gov.
Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius of
Curvature
ft
134.00 Lighting Rod 3/4'' x 3' 30 10.024 0.7637 0.0056 42106
132.00 (2) 800 10122 w/ Mount Pipe 30 9.718 0.7496 0.0053 42106
120.00 (2) 8' x 2'' Mount Pipe 30 7.906 0.6656 0.0035 15038
112.00 MX08FRO665-21 w/ Mount Pipe 31 6.756 0.6102 0.0024 9569
102.00 80010922 w/ Mount Pipe 31 5.436 0.5424 0.0013 6670
Maximum Tower Deflections - Design Wind
Section
No.
Elevation
ft
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
°
Twist
°
L1 134 - 96.75 73.769 12 5.5974 0.0411
L2 100.75 - 47.25 38.959 12 3.9399 0.0084
L3 53.25 - 0 10.241 12 1.8331 0.0021
Critical Deflections and Radius of Curvature - Design Wind
Elevation
ft
Appurtenance Gov.
Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius of
Curvature
ft
134.00 Lighting Rod 3/4'' x 3' 12 73.769 5.5974 0.0411 5866
132.00 (2) 800 10122 w/ Mount Pipe 12 71.523 5.4963 0.0387 5866
120.00 (2) 8' x 2'' Mount Pipe 12 58.233 4.8915 0.0252 2093
112.00 MX08FRO665-21 w/ Mount Pipe 12 49.793 4.4921 0.0172 1330
102.00 80010922 w/ Mount Pipe 12 40.088 4.0006 0.0092 925
Compression Checks
Pole Design Data
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
L1 134 - 96.75
(1)
TP27.77x16x0.25 37.25 0.00 0.0 20.834
2
-12.58 1218.80 0.010
L2 96.75 - 47.25
(2)
TP42.91x26.0061x0.5 53.50 0.00 0.0 64.296
1
-25.48 3761.32 0.007
August 24, 2021
134 Ft Monopole Tower Structural Analysis CCI BU No 5800245
Project Number CN7-925R2 / 2101398, Order 583375, Revision 2 Page 18
tnxTower Report - version 8.1.1.0
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
L3 47.25 - 0 (3) TP56.84x40.0142x0.5 53.25 0.00 0.0 89.411
6
-46.39 5230.58 0.009
Pole Bending Design Data
Section
No.
Elevation
ft
Size
Mux
kip-ft
Mnx
kip-ft
Ratio
Mux
Mnx
Muy
kip-ft
Mny
kip-ft
Ratio
Muy
Mny
L1 134 - 96.75
(1)
TP27.77x16x0.25 539.61 813.50 0.663 0.00 813.50 0.000
L2 96.75 - 47.25
(2)
TP42.91x26.0061x0.5 1914.03 3962.03 0.483 0.00 3962.03 0.000
L3 47.25 - 0 (3) TP56.84x40.0142x0.5 3894.15 7348.56 0.530 0.00 7348.56 0.000
Pole Shear Design Data
Section
No.
Elevation
ft
Size
Actual
Vu
K
Vn
K
Ratio
Vu
Vn
Actual
Tu
kip-ft
Tn
kip-ft
Ratio
Tu
Tn
L1 134 - 96.75
(1)
TP27.77x16x0.25 25.44 365.64 0.070 2.23 840.75 0.003
L2 96.75 - 47.25
(2)
TP42.91x26.0061x0.5 32.73 1128.40 0.029 2.22 4003.59 0.001
L3 47.25 - 0 (3) TP56.84x40.0142x0.5 41.47 1569.17 0.026 2.22 7742.26 0.000
Pole Interaction Design Data
Section
No.
Elevation
ft
Ratio
Pu
Pn
Ratio
Mux
Mnx
Ratio
Muy
Mny
Ratio
Vu
Vn
Ratio
Tu
Tn
Comb.
Stress
Ratio
Allow.
Stress
Ratio
Criteria
L1 134 - 96.75
(1)
0.010 0.663 0.000 0.070 0.003 0.679 1.050 4.8.2
L2 96.75 - 47.25
(2)
0.007 0.483 0.000 0.029 0.001 0.491 1.050 4.8.2
L3 47.25 - 0 (3) 0.009 0.530 0.000 0.026 0.000 0.540 1.050 4.8.2
Section Capacity Table
Section
No.
Elevation
ft
Component
Type
Size Critical
Element
P
K
øPallow
K
%
Capacity
Pass
Fail
L1 134 - 96.75 Pole TP27.77x16x0.25 1 -12.58 1279.74 64.7 Pass
L2 96.75 - 47.25 Pole TP42.91x26.0061x0.5 2 -25.48 3949.39 46.7 Pass
L3 47.25 - 0 Pole TP56.84x40.0142x0.5 3 -46.39 5492.11 51.4 Pass
Summary
Pole (L1) 64.7 Pass
RATING = 64.7 Pass
tnxTower Report - version 8.1.1.0
APPENDIX B
BASE LEVEL DRAWING
tnxTower Report - version 8.1.1.0
APPENDIX C
ADDITIONAL CALCULATIONS
Monopole Base Plate Connection
*TIA-222-H Section 15.5 Applied
#VALUE!
Anchor Rod Data Anchor Rod Summary (units of kips, kip-in)
(24) 2-1/4" ø bolts (A615-75 N; Fy=75 ksi, Fu=100 ksi) on 63.5" BC Pu_t = 120.65 Stress Rating
Anchor Spacing: 6 in Vu = 1.73 47.1%
Mu = n/a Pass
Base Plate Data
66.5" W x 3" Plate (A572-50; Fy=50 ksi, Fu=65 ksi); Clip: 17 in Base Plate Summary
Max Stress (ksi): 15.33 (Flexural)
Stiffener Data Allowable Stress (ksi): 45
N/A Stress Rating:32.4%Pass
Pole Data
56.84" x 0.5" 18-sided pole (A572-65; Fy=65 ksi, Fu=80 ksi)
46.39
41.47
Adjusted Pole Reactions
BU # 5800245
Applied Loads
Site Name Fox
Order # 583375 Rev. 2
Analysis Considerations
Site Info
TIA-222 Revision H
Grout Considered:No
Analysis ResultsConnection Properties
Iar (in) 1
Moment (kip-ft) 3894.15
Axial Force (kips) 46.39
Shear Force (kips) 41.47
Moment (kip-ft)
Axial Force (kips)
Shear Force (kips)
0.00
Analysis Date: 8/24/2021CCIplate - Version 4.1.2
Report File:TIA-222 Revison:Tower Type:Check Pier Capacity only at location of Max Moment?NoLocation:Soil Lateral CheckCompressionUpliftComp.Uplift10.21-3894.147.17-46.424209.38-41.4417.7%-Soil Vertical CheckCompressionUpliftGo to Soil Calculations868.62-3ksi173.18-60ksi186.89-40ksi1041.80-233.31-21.3%-40ftReinforced Concrete FlexureCompressionUplift0.5 ft10.29-4209.34-8322.72-7 ft48.2%-2736Reinforced Concrete ShearCompressionUplift1129.34-4 in300.31-5531.07-in53.9%-in*Rating per TIA-222-H Section 15.57.5# of Layers4121FALSE1 0 3.5 3.5 120 150 0 0 0.000 0.0000.00 0.00FALSE2 3.5 7.5 4 120 150 0 30 0.781 0.781 19FALSE3 7.5 18 10.5 58 87.6 0 30 1.063 1.063 13FALSE4 18 40 22 68 87.6 0 34 1.745 1.745 6 46Pier DiameterRebar QuantityRebar Cage DiameterRebar QuantityTie SpacingDrilled Pier FoundationBU # :Site Name:Order Number:MonopoleApplied LoadsMaterial PropertiesPier Design DataH5800245Fox 583375 Rev.2Moment (kip-ft)Axial Force (kips)Shear Force (kips)Concrete Strength, f'c:Rebar Strength, Fy:Tie Yield Strength, Fyt:CohesionlessCohesionlessCohesionlessUltimate Skin Friction Uplift Override (ksf)Critical Shear CapacityRating*Skin Friction (kips)Weight of Concrete (kips)Rating*Critical Shear (kip)End Bearing (kips)Axial (kips)Critical Depth (ft from TOC)Calculated Ultimate Skin Friction Uplift (ksf)Calculated Ultimate Skin Friction Comp (ksf)Ultimate Skin Friction Comp Override (ksf)Soil ProfileSoil TypeSPT Blow CountUlt. Gross Bearing Capacity (ksf)soil (pcf)concrete (pcf)Critical Depth (ft from TOC)21.3%Soil Interaction Rating*Rebar 2, Fy Override (ksi)Rebar 3, Fy Override (ksi)DepthCohesionlessLayerTop (ft)Bottom (ft)Thickness (ft)Groundwater DepthCohesion (ksf)Angle of Friction (degrees)Rebar SizePier Section 1Check LimitationApply TIA-222-H Section 15.5:Additional Longitudinal RebarShear Design OptionsCheck Shear along Depth of Pier:Utilize Shear-Friction Methodology:Override Critical Depth:Dv=0 (ft from TOC)Soil Safety FactorMax Moment (kip-ft)Rating*Ext. Above GradeCritical Moment (kip-ft)Critical Moment CapacityRating*From 0.5' above grade to 40' below gradeRebar SizeClear Cover to TiesTie SizeInput Effective Depths (else Actual):C:\Users\mkodey\Documents\Madhuri (WORK)\Reviews\CN7-925\CN7-925R2 SA\Analysis\CN7-925R2 BU_5800245 WO_2010461.eri.rtf53.9%Structural Foundation Rating*Total Capacity (kips)N/AAnalysis ResultsRebar & Pier OptionsEmbedded Pole InputsBelled Pier InputsVersion 5.0.3
ASCE 7 Hazards Report
Address:
No Address at This
Location
Standard:ASCE/SEI 7-16
Risk Category:II
Soil Class:D - Stiff Soil
Elevation:18.54 ft (NAVD 88)
Latitude:
Longitude:
27.481714
-80.375744
Wind
Results:
Wind Speed: 158 Vmph
10-year MRI 87 Vmph
25-year MRI 106 Vmph
50-year MRI 118 Vmph
100-year MRI 130 Vmph
Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2
Date Accessed: Thu Aug 19 2021
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds
correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability =
0.00143, MRI = 700 years).
Site is in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Glazed openings shall be protected
against wind-borne debris as specified in Section 26.12.3.
Page 1 of 3https://asce7hazardtool.online/Thu Aug 19 2021
SS : 0.05
S1 : 0.028
F a : 1.6
F v : 2.4
SMS : 0.08
SM1 : 0.068
SDS : 0.053
SD1 : 0.045
T L : 8
PGA : 0.023
PGA M : 0.037
F PGA : 1.6
Ie : 1
C v : 0.7
Design Response Spectrum
S (g) vs T(s)a
MCE Response SpectrumR
S (g) vs T(s)a
Design Vertical Response Spectrum
S (g) vs T(s)a
MCE Vertical Response SpectrumR
S (g) vs T(s)a
Seismic
Site Soil Class:
Results:
Seismic Design Category
D - Stiff Soil
A
Data Accessed:
Date Source:
Thu Aug 19 2021
USGS Seismic Design Maps based on ASCE/SEI 7-16 and ASCE/SEI 7-16
Table 1.5-2. Additional data for site-specific ground motion procedures in
accordance with ASCE/SEI 7-16 Ch. 21 are available from USGS.
Page 2 of 3https://asce7hazardtool.online/Thu Aug 19 2021
Ice
Results:
Data Source:
Date Accessed:
Ice Thickness: 0.00 in.
Concurrent Temperature: 25 F
Gust Speed: 30 mph
Standard ASCE/SEI 7-16, Figs. 10-2 through 10-8
Thu Aug 19 2021
Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys
and gorges may exceed the mapped values.
Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds,
for a 500-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain.
Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice
thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may
exceed the mapped values.
The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of
any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers;
or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from
reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability,
currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement,
affiliation, relationship, or sponsorship of such third-party content by or from ASCE.
ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent
professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such
professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard.
In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors,
employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential
damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by
law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data
provided by the ASCE 7 Hazard Tool.
Page 3 of 3https://asce7hazardtool.online/Thu Aug 19 2021