FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Standard Pacific RB Laurel Model Lot 47
Builder Name: Standard Pacific Homes
Street: 3rt;q 1VW &tdGI%8C
A
Mr, City, State, Zip: Port St. Lucie, FL , r:Owner:
Standard Pacific Homes
Design Location: FL, ST LUCIE_CO_INTL l t�
1. New construction or existing New (From Plans)
9. Wall Types (4248.6`'sgft.)
Insulation Area
a. Concrete Block - Int Insul, Exterior
R=4.1 3813.60 ft2
2. Single family or multiple family Single-family
b. Frame - Wood, Adjacent
R=11.0 345.00 ft2
3. Number of units, if multiple family 1
c. Interior Wall, Interior
R=11.0 90.00 ft2
4. Number of Bedrooms. 5
d. N/A
R= ft2
10. Ceiling Types (2291.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 2291.00 ft2
6. Conditioned floor area above grade (ft2) 4382
b. N/A
R= ft2
c. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
11. Ducts
R ft2
7. Windows(697.9 sqft.) Description Area
a. Sup: AC 1 First Floor, Ret: AC 1 First
Floor, AH: A 6 440
a. U-Factor: Dbl, U=0.60 475.83 ft2
b. Sup: Attic, Ret: Attic, AH: AC 2 Second
Floor 6 380
SHGC: SHGC=0.31
b. U-Factor: Dbl, U=0.59 96.00 ft2
12. Cooling systems
kBtu/hr Efficiency
a. Central Unit
42.0 SEER:15.50
SHGC: SHGC=0.32
b. Central Unit
29.0 SEER:15.00
c. U-Factor: Dbl, U=0.77 68.00 ft2
SHGC: SHGC=0.22
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 58.05 ft2
a. Electric Heat Pump
42.0 HSPF:8.60
- SHGC: other (see details)
b. Electric Heat Pump
28.4 HSPF:8.50
Area Weighted Average Overhang Depth: 4.863 ft.
Area Weighted Average SHGC: 0.303
14. Hot water systems
a. Electric
Cap: 50 gallons
8.--Floor Types (2317.0 sqft.) Insulation Area
EF:0.910
a. Slab -On -Grade Edge Insulation R=0.0 2091.00 ft2
b. Conservation features
b. Floor over Garage R=11.0 226.00 ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 55.32
PASS
Glass/Floor Area: 0.159
Total Standard Reference Loads: 88.96
I hereby certify that the plans and specifications covered by
Review of the plans and
1,131
O� THE ST14T�p
this calculation are in compliance with the Florida Energy
specifications covered by this
,j� _ : , Off,
s' r g v
Code. t' Digitally signed b Chris Wildroudt
cn=Chris Wildroudt, c=US,
calculation indicates compliance
k� � , `_
h �ii, •,.,.��
=Engineered Air, t l c, eu=New
Chris o=
with the Florida Energy Code.
+++r+".y; : •',- a
PREPARED BY: construction Sales and
ngmeenng,
Before construction is completed
i4 d
DATE: _ -aa= o.
this building will be inspected for
O a
_�
VVIIUIUU �m ''
F Date: 2013,11,12 10,37,16 -05'00'
compliance with Section 553.908
* "'
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
1�,
COD WE'D
with the Florida Ener
OWNER/AGENT: I
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with 403.2.2.1.1.
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
- Heat sys #2 may be undersized. Size of 28.4 was increased to 29.5 for simulation. Please review the Manual J8 report.
11/12/2013 10:35 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6
PROJECT
Title:
Standard Pacific RB Laurel M
Bedrooms: 5
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 4382
Lot #
47
Owner:
Standard Pacific Homes
Total Stories: 2
Block/SubDivision:
Riverbend
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Standard Pacific Homes
Rotate Angle: 0
Street:
Permit Office:
Cross Ventilation:
County:
St. Lucie
Jurisdiction:
Whole House Fan:
City, State, Zip:
Port St. Lucie ,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
v Design Location TMY Site
Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, ST LUCIE_CO_INTL FL_ST_LUCIE_CO_INTL 2 39 90
70
72 722
58
Medium
BLOCKS
Number
Name Area
Volume
1
Blockl 2091
20910
2
Block2 2291
21375.0292
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
AC 1 First Floor 2091
20910 No 6
1
1 Yes
Yes
Yes
2
AC 2 Second Floor 2291
21375.03 No 4
4
1 Yes
Yes
Yes
FLOORS
#
Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio AC 1 First Floor 205 ft 0
2091 ft2
___
0 0
1
2 Floor over Garage AC 2 Second Flo ___ _-_
226 ft2
11
0 0
1
ROOF
/
Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
V #
Type Materials
Area Area Color
Absor.
Tested
Tested Insul.
(deg)
1
Hip Barrel tile
2562 ft2 0 ft2 Medium
0.65
No 0.9
No 0
26.6
ATTIC
V #
Type Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic Vented 300 2291 ft2
N N
11 /12/2013 10:35 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6
CEILING
#
Ceiling Type Space
R-Value
Area Framing Frac
Truss Type
1
Under Attic (Vented) AC 2 Second Flo 30
2291 ft2 0.11
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing
Framing
Solar
Below
# Ornt
10
Space
Wall lype
Et
In
Et In Area
13-Vaille
Fraction
Ahsor
Grade%
_ 1 E
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
11.5
0
10 0 115 ft2
0.4
0
0.4
0
_ 2 S
Exterior
Concrete Block - Int Ins9C 1 First Flo
4.1
52
0
10 0 520 ft2
0.4
0
0.4
0
_ 3 S
Exterior
Concrete Block - Int InsiNC 1 First Flo
4.1
10
0
10 0 100 ft2
0.4
0
0.4
0
_ 4 W
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
19
0
10 0 190 ft2
0.4
0
0.4
0
_ 5 W
Exterior
Concrete Block - Int InsiNC 1 First Flo
4.1
21
0
10 0 210 ft2
0.4
0
0.4
0
_ 6 W
Exterior
Concrete Block - Int InsiNC 1 First Flo
4.1
13
0
10 0 130 ft2
0.4
0
0.4
0
_ 7 N
Exterior
Concrete Block - Int InsiNC 1 First Flo
4.1
44
0
10 0 440 ft2
0.4
0
0.4
0
_ 8 E
Garage
Frame - Wood AC 1 First Flo
11
22.5
0
10 0 225 ft2
0.4
0.4
0
_ 9 N
Garage
Frame - Wood AC 1 First Flo
11
12
0
10 0 120 ft2
0.4
0.4
0
_ 10 E
Exterior
Concrete Block - Int InsiNC 2 Second
4.1
53
0
9.33 0 494.4899
0.4
0
0.4
0
_ 11 S
Exterior
Concrete Block - Int InsBJC 2 Second
4.1
60
0
9.33 0 559.7999
0.4
0
0.4
0
_ 12 W
Exterior
Concrete Block - Int InstWC 2 Second
4.1
53
0
9.33 0 494.4899
0.4
0
0.4
0
_ 13 N
Exterior
Concrete Block - Int InsAC 2 Second
4.1
60
0
9.33 0 559.7999
0.4
0
0.4
0
14 N
AC 1 First
Interior Wall AC 2 Second
11
10
0
9 90 ft2
0
0
0.75
0
DOORS
#
Ornt
Door Type Space
Storms U-Value
Width
Area
Ft
In
FHeigh'n
1
E
Wood AC 1 First Flo
None 0.39 2.5 0
8 0
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Area Depth
Separation
Int Shade
Screening
1
E 1
Metal Low-E Double Yes
0.77
0.22
48 ft2 5 ft 0 in
2 ft 0 in
None
None
2
S 2
Metal Low-E Double Yes
0.6
0.31
48.51000 2 ft 0 in
12 ft 0 in
None
None
3
S 2
Metal Low-E Double Yes
0.6
0.31
27.34560 2 ft 0 in
12 ft 0 in
None
None
4
S 3
Metal Low-E Double Yes
0.77
0.22
20 ft2 39.5 ft 0 i
2 ft 0 in
None
None
5
W 4
Metal Low-E Double Yes
0.6
0.31
83.93579 6 ft 0 in
2 ft 0 in
None
None
6
W 5
Metal Low-E Double Yes
0.59
0.32
96 ft2 10 ft 0 in
2 ft 0 in
None
None
7
W 6
Metal Low-E Double Yes
0.6
0.31
6.652800 2 ft 0 in
12 ft 0 in
None
None
8
N 7
Metal Low-E Double Yes
0.6
0.31
32.34000 2 ft 0 in
12 ft 0 in
None
None
9
N 7
Metal Low-E Double Yes
0.6
0.31
9.180000 2 ft 0 in
12 ft 0 in
None
None
10
E 10
Metal Low-E Double Yes
0.6
0.31
22068000 2 ft 0 in
2 ft 0 in
None
None
11
E 10
Metal Low-E Double Yes
0.6
0.31
27.54000 2 ft 0 in
2 ft 0 in
None
None
12
E 10
Metal Low-E Double Yes
0.4
0.31
4 ft2 2 ft 0 in
2 ft 0 in
None
None
13
S 11
Metal Low-E Double Yes
0.6
0.31
65.45000 2 ft 0 in
2 ft 0 in
None
None
14
S 11
Metal Low-E Double Yes
0.4
0.31
21.78000 2 ft 0 in
2 ft 0 in
None
None
15
W 12
Metal Low-E Double Yes
0.6
0.31
11207099 2 ft 0 in
2 ft 0 in
None
None
16
W 12
Metal Low-E Double Yes
0.4
0.31
21.78000 2 ft 0 in
2 ft 0 in
None
None
11 /12/2013 10:35 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6
WINDOWS
Orientation shown is the entered, Proposed orientation.
#
Wall
Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Area Depth Separation Int Shade
Screening
17
18
19
N 13 Metal Low-E Double Yes
N 13 Metal Low-E Double Yes
N 13 Metal Low-E Double Yes
0.6 0.31 26.18000 2 ft 0 in 2 ft 0 in None
0.6 0.31 13.30560 2 ft 0 in 2 ft 0 in None
0.4 0.31 10.48499 2 ft 0 in 2 ft 0 in None
None
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
400 ft2
174 ft2
56 ft 9 ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Best Guess
0.000500
5747.0 315.50 593.35 0.4616 8.1546
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
2
Electric Heat Pump
Electric Heat Pump
None
None
HSPF: 8.6 42 kBtu/hr 1
HSPF: 8.5 28.4 kBtu/hr 2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit
Central Unit
Split
Split
SEER: 15.5 42 kBtu/hr 1260 cfm 0.75 1
SEER: 15 29 kBtu/hr 870 cfm 0.75 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.91 50 gal 80 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
/
v #
--- Supply ----
Location R-Value Area
---- Return — Air Percent
Location Area Leakage Type Handler CFM 25 Leakage QN RLF
HVAC #
Heat Cool
1
2
AC 1 First Flo 6 440 ft2
Attic 6 380 ft2
AC 1 First Flo 30 ft2 Default Leakage AC 2 Secon (Default) (Default) %
Attic 120 ft' Default Leakage AC 2 Secon (Default) (Default) %
1 1
2 2
11/12/2013 10:35 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6
TEMPERATURES
Programabl[e ]Thermostat: Y
Heating [X] Jan H Feb
[[ ]]Jan Feb
Mar
ki Mar
Apr
Ceiling Fans:
May
LXJun
Jun
Jul
rl Jul
Aug
ri Aug
ri
Sep
Sep
Oct
Oct
Nov
Nov
Dec
DecVenting
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78•
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
68
68
68
68
68
68
68
66
68
66
Heating (WEH)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
68
68
68
68
68
68
68
66
68
66
11/12/2013 10:35 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: PERMIT #:
Port St. Lucie, FL,
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required.
Fireplaces: gasketed doors & outdoor combustion air. Must complete
ir
envelope leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating
controls.
and cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
in Section 503.2.7.2 of this code.
sealed accordance with
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to =
R-2 + accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawispaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
f
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
/
11/12/2013 10:35 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6
try
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 62
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz)
7. Windows- Description
a. U-Factor: Dbl, U=0.60
SHGC: SHGC=0.31
b. U-Factor: Dbl, U=0.59
SHGC: SHGC=0.32
c. U-Factor: Dbl, U=0.77
SHGC: SHGC=0.22
d. U-Factor: other (see details)
SHGC: other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
-a. Slab -On -Grade Edge Insulation
b. Floor over Garage
c. N/A
, Port St. Lucie, FL,
New (From Plans)
9. Wall Types
Insulation
Area
a. Concrete Block - Int Insul, Exterior
R=4.1
3813.60 ftz
Single-family
b. Frame - Wood, Adjacent
R=11.0
345.00 ft2
1
c. Interior Wall, Interior
R=11.0
90.00 ftz
5
d. N/A
R=
ftz
10. Ceiling Types
Insulation
Area
No
a. Under Attic (Vented)
R=30.0
2291.00 ftz
4382
b. N/A
R=
ftz
c. N/A
R=
ftz
Area
11. Ducts
R ftz
475.83 ftz
a. Sup: AC 1 First Floor, Ret: AC 1 First Floor, AH: A 6 440
b. Sup: Attic, Ret: Attic, AH: AC 2 Second Floor
6 380
96.00 ftz
12. Cooling systems
kBtu/hr
Efficiency
68.00 ftz
a. Central Unit
42.0
SEER:15.50
b. Central Unit
29.0
SEER:15.00
Insulation
R=0.0
R=11.0
R=
58.05 ftz
13. Heating systems
kBtu/hr Efficiency
a. Electric Heat Pump
42.0 HSPF:8.60
4.863 ft.
b. Electric Heat Pump
28.4 HSPF:8.50
0.303
Area
14. Hot water systems
Cap: 50 gallons
2091.00 ft z
a. Electric
EF: 0.91
226.00 ftz
b. Conservation features
ftz
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
W
Builder Signature: pn,t,Q •--� Date: 411 1, V
Address of New Home: c,,jvj (a �j City/FL Zip: PairgL,
2%0.
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
Rhvac"- Res�denttal 8� light Commercial HVAC Loads ,;� . Elite Software Development,°Inca
EngirieeredAir`iLLG'' gar xis_° ° .LaurellUlodel.
Mar"ate,.FL,33063 � =;'- ,,n ''°,�, ."� h?;•_:t _ � _ �` -'Pa e2
Project Report
Project Title:
Laurel Model
Designed By:
Greg Bolinsky
Project Date:
Wednesday, October 23, 2013
Client Name:
Standard Pacific Homes
Company Name:
Engineered Air LLC CACO45860
Company Representative:
Greg Bolinsky
Company Address:
2520 N Andrews Ave Ext
Company City:
Pompano Beach, FL 33064
Company Phone:
954 974-7277
Company Fax:
954 973-1883
Reference City:
Fort Pierce, Florida
Building Orientation:
House faces East
Daily Temperature Range:
Medium
Latitude:
27 Degrees
Elevation:
25 ft.
Altitude Factor:
0.999
Outdoor
Outdoor Outdoor Indoor
Indoor
Grains
Dry Bulb
Wet Bulb Rel.Hum Rel.Hum
Dry Bulb
Difference
Winter:
42
39.4 n/a n/a
70
n/a
Summer:
90
75 50% 50%
72
48
Total Building Supply CFM: 2,219 CFM Per Square ft.: 0.503
Square ft. of Room Area: 4,408 Square ft. Per Ton: 838
Volume (ft) of Cond. Space: 42,528
^°lt,
Builclin .Loads g ,,ppAA ,7
Total Heating Required Including Ventilation Air: 45,693 Btuh 45.693 MBH
Total Sensible Gain: 48,781 Btuh 77 %'
Total Latent,Gain: 14,347 Btuh 23 %
Total Cooling Required Including Ventilation Air: 63,127 Btuh 5.26 Tons (Based On Sensible + Latent)
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
S:\ ...\Stan Pac RB Laurel 5512 WBonus PSL.rh9 Tuesday, November 12, 2013, 10:14 AM
Total Building Summary Loads
Lo-E French Door: Glazing-Low-E French Door, u-value
68
1,465
0
1,838
1,838
0.77, SHGC 0.22
Lo-E operable: Glazing-Low-E Operable Glass, u-value
475.8
8,000
0
12,754
12,754
0.6, SHGC 0.31
Lo-E S G D: Glazing -Low E Sliding Glass Door, ground
96
1,587
0
2,361
2,361
reflectance = 0.32, u-value 0.59, SHGC 0.32
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
58
651
0
1,328
1,328
0.4, SHGC 0.31
11 D: Door -Wood - Solid Core
20
117
0
117
117
13A-4ocs: Wall -Block, board insulation only, R-4 board
3115.7
12,474
0
7,388
7,388
insulation, open core, siding finish
12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud
325
473
0
473
473
cavity, no board insulation, siding finish, wood studs
16D-30: Roof/Ceiling-Under Attic with Insulation on Attic
2317
2,076
0
.2,224
2,224
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark Tile,
Slate or Concrete, R-30 insulation
22A-pl: Floor -Slab on grade, No edge insulation, no
205
5,677
0
0
0
insulation below floor, any floor cover, passive, light
dry soil
20P-11: Floor -Over open crawl space or garage,
226
494
0
176
176
Passive, R-11 blanket insulation, any cover
_
Subtotals for structure:
33,014
0
28,659
28,659
_
People:
10
3,000
2,800
5,800
Equipment:
4,600
3,000
7,600
Lighting:
700
2,387
2,387
'-Ductwork:
4,609
2,614
4,948
7,562
Infiltration: Winter CFM: 262, Summer CFM: 135
8,070
4,133
2,439
6,572
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0
0
AED Excursion:
0
0
4,547
4,547
Total Building Load Totals:
45,693
14,347
48,781
63,127
Total Building Supply CFM: 2,219
CFM Per Square ft.:
0.503
Square ft. of Room Area: 4,408
Square ft. Per Ton:
838
Volume (ft') of Cond. Space: 42,528
d
r 4` "-'YYV M M ,-�drhs Yi"' G{�v'_.:4d rl � .,r3'e �1 *i'4*4Q I' ?n*1
Total Heating Required Including Ventilation Air:
45,693
Btuh 45.693 MBH
Total Sensible Gain:
48,781
Btuh 77 %
Total Latent Gain:
14,347
Btuh 23 %
Total Cooling Required Including Ventilation Air:
63,127
Btuh 5.26 Tons (Based
On Sensible + Latent)
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
S:\ ...\Stan Pac RB Laurel 5512 WBonus PSL.rh9 Tuesday, November 12, 2013, 10:14 AM