Loading...
HomeMy WebLinkAboutEnergy Efficiency Code 4-17-14t i FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Standard Pacific RB Laurel Model Lot 47 Builder Name: Standard Pacific Homes Street: 3rt;q 1VW &tdGI%8C A Mr, City, State, Zip: Port St. Lucie, FL , r:Owner: Standard Pacific Homes Design Location: FL, ST LUCIE_CO_INTL l t� 1. New construction or existing New (From Plans) 9. Wall Types (4248.6`'sgft.) Insulation Area a. Concrete Block - Int Insul, Exterior R=4.1 3813.60 ft2 2. Single family or multiple family Single-family b. Frame - Wood, Adjacent R=11.0 345.00 ft2 3. Number of units, if multiple family 1 c. Interior Wall, Interior R=11.0 90.00 ft2 4. Number of Bedrooms. 5 d. N/A R= ft2 10. Ceiling Types (2291.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2291.00 ft2 6. Conditioned floor area above grade (ft2) 4382 b. N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(697.9 sqft.) Description Area a. Sup: AC 1 First Floor, Ret: AC 1 First Floor, AH: A 6 440 a. U-Factor: Dbl, U=0.60 475.83 ft2 b. Sup: Attic, Ret: Attic, AH: AC 2 Second Floor 6 380 SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.59 96.00 ft2 12. Cooling systems kBtu/hr Efficiency a. Central Unit 42.0 SEER:15.50 SHGC: SHGC=0.32 b. Central Unit 29.0 SEER:15.00 c. U-Factor: Dbl, U=0.77 68.00 ft2 SHGC: SHGC=0.22 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 58.05 ft2 a. Electric Heat Pump 42.0 HSPF:8.60 - SHGC: other (see details) b. Electric Heat Pump 28.4 HSPF:8.50 Area Weighted Average Overhang Depth: 4.863 ft. Area Weighted Average SHGC: 0.303 14. Hot water systems a. Electric Cap: 50 gallons 8.--Floor Types (2317.0 sqft.) Insulation Area EF:0.910 a. Slab -On -Grade Edge Insulation R=0.0 2091.00 ft2 b. Conservation features b. Floor over Garage R=11.0 226.00 ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 55.32 PASS Glass/Floor Area: 0.159 Total Standard Reference Loads: 88.96 I hereby certify that the plans and specifications covered by Review of the plans and 1,131 O� THE ST14T�p this calculation are in compliance with the Florida Energy specifications covered by this ,j� _ : , Off, s' r g v Code. t' Digitally signed b Chris Wildroudt cn=Chris Wildroudt, c=US, calculation indicates compliance k� � , `_ h �ii, •,.,.�� =Engineered Air, t l c, eu=New Chris o= with the Florida Energy Code. +++r+".y; : •',- a PREPARED BY: construction Sales and ngmeenng, Before construction is completed i4 d DATE: _ -aa= o. this building will be inspected for O a _� VVIIUIUU �m '' F Date: 2013,11,12 10,37,16 -05'00' compliance with Section 553.908 * "' I hereby certify that this building, as designed, is in compliance Florida Statutes. 1�, COD WE'D with the Florida Ener OWNER/AGENT: I BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 403.2.2.1.1. - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist - Heat sys #2 may be undersized. Size of 28.4 was increased to 29.5 for simulation. Please review the Manual J8 report. 11/12/2013 10:35 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 PROJECT Title: Standard Pacific RB Laurel M Bedrooms: 5 Address Type: Lot Information Building Type: User Conditioned Area: 4382 Lot # 47 Owner: Standard Pacific Homes Total Stories: 2 Block/SubDivision: Riverbend # of Units: 1 Worst Case: No PlatBook: Builder Name: Standard Pacific Homes Rotate Angle: 0 Street: Permit Office: Cross Ventilation: County: St. Lucie Jurisdiction: Whole House Fan: City, State, Zip: Port St. Lucie , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL_ST_LUCIE_CO_INTL 2 39 90 70 72 722 58 Medium BLOCKS Number Name Area Volume 1 Blockl 2091 20910 2 Block2 2291 21375.0292 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 AC 1 First Floor 2091 20910 No 6 1 1 Yes Yes Yes 2 AC 2 Second Floor 2291 21375.03 No 4 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio AC 1 First Floor 205 ft 0 2091 ft2 ___ 0 0 1 2 Floor over Garage AC 2 Second Flo ___ _-_ 226 ft2 11 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel tile 2562 ft2 0 ft2 Medium 0.65 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2291 ft2 N N 11 /12/2013 10:35 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) AC 2 Second Flo 30 2291 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Ornt 10 Space Wall lype Et In Et In Area 13-Vaille Fraction Ahsor Grade% _ 1 E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 11.5 0 10 0 115 ft2 0.4 0 0.4 0 _ 2 S Exterior Concrete Block - Int Ins9C 1 First Flo 4.1 52 0 10 0 520 ft2 0.4 0 0.4 0 _ 3 S Exterior Concrete Block - Int InsiNC 1 First Flo 4.1 10 0 10 0 100 ft2 0.4 0 0.4 0 _ 4 W Exterior Concrete Block - Int InsAC 1 First Flo 4.1 19 0 10 0 190 ft2 0.4 0 0.4 0 _ 5 W Exterior Concrete Block - Int InsiNC 1 First Flo 4.1 21 0 10 0 210 ft2 0.4 0 0.4 0 _ 6 W Exterior Concrete Block - Int InsiNC 1 First Flo 4.1 13 0 10 0 130 ft2 0.4 0 0.4 0 _ 7 N Exterior Concrete Block - Int InsiNC 1 First Flo 4.1 44 0 10 0 440 ft2 0.4 0 0.4 0 _ 8 E Garage Frame - Wood AC 1 First Flo 11 22.5 0 10 0 225 ft2 0.4 0.4 0 _ 9 N Garage Frame - Wood AC 1 First Flo 11 12 0 10 0 120 ft2 0.4 0.4 0 _ 10 E Exterior Concrete Block - Int InsiNC 2 Second 4.1 53 0 9.33 0 494.4899 0.4 0 0.4 0 _ 11 S Exterior Concrete Block - Int InsBJC 2 Second 4.1 60 0 9.33 0 559.7999 0.4 0 0.4 0 _ 12 W Exterior Concrete Block - Int InstWC 2 Second 4.1 53 0 9.33 0 494.4899 0.4 0 0.4 0 _ 13 N Exterior Concrete Block - Int InsAC 2 Second 4.1 60 0 9.33 0 559.7999 0.4 0 0.4 0 14 N AC 1 First Interior Wall AC 2 Second 11 10 0 9 90 ft2 0 0 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Area Ft In FHeigh'n 1 E Wood AC 1 First Flo None 0.39 2.5 0 8 0 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Double Yes 0.77 0.22 48 ft2 5 ft 0 in 2 ft 0 in None None 2 S 2 Metal Low-E Double Yes 0.6 0.31 48.51000 2 ft 0 in 12 ft 0 in None None 3 S 2 Metal Low-E Double Yes 0.6 0.31 27.34560 2 ft 0 in 12 ft 0 in None None 4 S 3 Metal Low-E Double Yes 0.77 0.22 20 ft2 39.5 ft 0 i 2 ft 0 in None None 5 W 4 Metal Low-E Double Yes 0.6 0.31 83.93579 6 ft 0 in 2 ft 0 in None None 6 W 5 Metal Low-E Double Yes 0.59 0.32 96 ft2 10 ft 0 in 2 ft 0 in None None 7 W 6 Metal Low-E Double Yes 0.6 0.31 6.652800 2 ft 0 in 12 ft 0 in None None 8 N 7 Metal Low-E Double Yes 0.6 0.31 32.34000 2 ft 0 in 12 ft 0 in None None 9 N 7 Metal Low-E Double Yes 0.6 0.31 9.180000 2 ft 0 in 12 ft 0 in None None 10 E 10 Metal Low-E Double Yes 0.6 0.31 22068000 2 ft 0 in 2 ft 0 in None None 11 E 10 Metal Low-E Double Yes 0.6 0.31 27.54000 2 ft 0 in 2 ft 0 in None None 12 E 10 Metal Low-E Double Yes 0.4 0.31 4 ft2 2 ft 0 in 2 ft 0 in None None 13 S 11 Metal Low-E Double Yes 0.6 0.31 65.45000 2 ft 0 in 2 ft 0 in None None 14 S 11 Metal Low-E Double Yes 0.4 0.31 21.78000 2 ft 0 in 2 ft 0 in None None 15 W 12 Metal Low-E Double Yes 0.6 0.31 11207099 2 ft 0 in 2 ft 0 in None None 16 W 12 Metal Low-E Double Yes 0.4 0.31 21.78000 2 ft 0 in 2 ft 0 in None None 11 /12/2013 10:35 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 WINDOWS Orientation shown is the entered, Proposed orientation. # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Area Depth Separation Int Shade Screening 17 18 19 N 13 Metal Low-E Double Yes N 13 Metal Low-E Double Yes N 13 Metal Low-E Double Yes 0.6 0.31 26.18000 2 ft 0 in 2 ft 0 in None 0.6 0.31 13.30560 2 ft 0 in 2 ft 0 in None 0.4 0.31 10.48499 2 ft 0 in 2 ft 0 in None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 400 ft2 174 ft2 56 ft 9 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess 0.000500 5747.0 315.50 593.35 0.4616 8.1546 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Heat Pump Electric Heat Pump None None HSPF: 8.6 42 kBtu/hr 1 HSPF: 8.5 28.4 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit Central Unit Split Split SEER: 15.5 42 kBtu/hr 1260 cfm 0.75 1 SEER: 15 29 kBtu/hr 870 cfm 0.75 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.91 50 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / v # --- Supply ---- Location R-Value Area ---- Return — Air Percent Location Area Leakage Type Handler CFM 25 Leakage QN RLF HVAC # Heat Cool 1 2 AC 1 First Flo 6 440 ft2 Attic 6 380 ft2 AC 1 First Flo 30 ft2 Default Leakage AC 2 Secon (Default) (Default) % Attic 120 ft' Default Leakage AC 2 Secon (Default) (Default) % 1 1 2 2 11/12/2013 10:35 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 TEMPERATURES Programabl[e ]Thermostat: Y Heating [X] Jan H Feb [[ ]]Jan Feb Mar ki Mar Apr Ceiling Fans: May LXJun Jun Jul rl Jul Aug ri Aug ri Sep Sep Oct Oct Nov Nov Dec DecVenting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78• Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 11/12/2013 10:35 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: PERMIT #: Port St. Lucie, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete ir envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating controls. and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and in Section 503.2.7.2 of this code. sealed accordance with 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawispaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special f equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. / 11/12/2013 10:35 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 try ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 62 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftz) 7. Windows- Description a. U-Factor: Dbl, U=0.60 SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.59 SHGC: SHGC=0.32 c. U-Factor: Dbl, U=0.77 SHGC: SHGC=0.22 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types -a. Slab -On -Grade Edge Insulation b. Floor over Garage c. N/A , Port St. Lucie, FL, New (From Plans) 9. Wall Types Insulation Area a. Concrete Block - Int Insul, Exterior R=4.1 3813.60 ftz Single-family b. Frame - Wood, Adjacent R=11.0 345.00 ft2 1 c. Interior Wall, Interior R=11.0 90.00 ftz 5 d. N/A R= ftz 10. Ceiling Types Insulation Area No a. Under Attic (Vented) R=30.0 2291.00 ftz 4382 b. N/A R= ftz c. N/A R= ftz Area 11. Ducts R ftz 475.83 ftz a. Sup: AC 1 First Floor, Ret: AC 1 First Floor, AH: A 6 440 b. Sup: Attic, Ret: Attic, AH: AC 2 Second Floor 6 380 96.00 ftz 12. Cooling systems kBtu/hr Efficiency 68.00 ftz a. Central Unit 42.0 SEER:15.50 b. Central Unit 29.0 SEER:15.00 Insulation R=0.0 R=11.0 R= 58.05 ftz 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 42.0 HSPF:8.60 4.863 ft. b. Electric Heat Pump 28.4 HSPF:8.50 0.303 Area 14. Hot water systems Cap: 50 gallons 2091.00 ft z a. Electric EF: 0.91 226.00 ftz b. Conservation features ftz None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. W Builder Signature: pn,t,Q •--� Date: 411 1, V Address of New Home: c,,jvj (a �j City/FL Zip: PairgL, 2%0. *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Rhvac"- Res�denttal 8� light Commercial HVAC Loads ,;� . Elite Software Development,°Inca EngirieeredAir`iLLG'' gar xis_° ° .LaurellUlodel. Mar"ate,.FL,33063 � =;'- ,,n ''°,�, ."� h?;•_:t _ � _ �` -'Pa e2 Project Report Project Title: Laurel Model Designed By: Greg Bolinsky Project Date: Wednesday, October 23, 2013 Client Name: Standard Pacific Homes Company Name: Engineered Air LLC CACO45860 Company Representative: Greg Bolinsky Company Address: 2520 N Andrews Ave Ext Company City: Pompano Beach, FL 33064 Company Phone: 954 974-7277 Company Fax: 954 973-1883 Reference City: Fort Pierce, Florida Building Orientation: House faces East Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 90 75 50% 50% 72 48 Total Building Supply CFM: 2,219 CFM Per Square ft.: 0.503 Square ft. of Room Area: 4,408 Square ft. Per Ton: 838 Volume (ft) of Cond. Space: 42,528 ^°lt, Builclin .Loads g ,,ppAA ,7 Total Heating Required Including Ventilation Air: 45,693 Btuh 45.693 MBH Total Sensible Gain: 48,781 Btuh 77 %' Total Latent,Gain: 14,347 Btuh 23 % Total Cooling Required Including Ventilation Air: 63,127 Btuh 5.26 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. S:\ ...\Stan Pac RB Laurel 5512 WBonus PSL.rh9 Tuesday, November 12, 2013, 10:14 AM Total Building Summary Loads Lo-E French Door: Glazing-Low-E French Door, u-value 68 1,465 0 1,838 1,838 0.77, SHGC 0.22 Lo-E operable: Glazing-Low-E Operable Glass, u-value 475.8 8,000 0 12,754 12,754 0.6, SHGC 0.31 Lo-E S G D: Glazing -Low E Sliding Glass Door, ground 96 1,587 0 2,361 2,361 reflectance = 0.32, u-value 0.59, SHGC 0.32 Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value 58 651 0 1,328 1,328 0.4, SHGC 0.31 11 D: Door -Wood - Solid Core 20 117 0 117 117 13A-4ocs: Wall -Block, board insulation only, R-4 board 3115.7 12,474 0 7,388 7,388 insulation, open core, siding finish 12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud 325 473 0 473 473 cavity, no board insulation, siding finish, wood studs 16D-30: Roof/Ceiling-Under Attic with Insulation on Attic 2317 2,076 0 .2,224 2,224 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Tile, Slate or Concrete, R-30 insulation 22A-pl: Floor -Slab on grade, No edge insulation, no 205 5,677 0 0 0 insulation below floor, any floor cover, passive, light dry soil 20P-11: Floor -Over open crawl space or garage, 226 494 0 176 176 Passive, R-11 blanket insulation, any cover _ Subtotals for structure: 33,014 0 28,659 28,659 _ People: 10 3,000 2,800 5,800 Equipment: 4,600 3,000 7,600 Lighting: 700 2,387 2,387 '-Ductwork: 4,609 2,614 4,948 7,562 Infiltration: Winter CFM: 262, Summer CFM: 135 8,070 4,133 2,439 6,572 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 4,547 4,547 Total Building Load Totals: 45,693 14,347 48,781 63,127 Total Building Supply CFM: 2,219 CFM Per Square ft.: 0.503 Square ft. of Room Area: 4,408 Square ft. Per Ton: 838 Volume (ft') of Cond. Space: 42,528 d r 4` "-'YYV M M ,-�drhs Yi"' G{�v'_.:4d rl � .,r3'e �1 *i'4*4Q I' ?n*1 Total Heating Required Including Ventilation Air: 45,693 Btuh 45.693 MBH Total Sensible Gain: 48,781 Btuh 77 % Total Latent Gain: 14,347 Btuh 23 % Total Cooling Required Including Ventilation Air: 63,127 Btuh 5.26 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. S:\ ...\Stan Pac RB Laurel 5512 WBonus PSL.rh9 Tuesday, November 12, 2013, 10:14 AM