Loading...
HomeMy WebLinkAboutSewage (2)J t i STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION PERMIT CONSTRUCTION PERMIT FOR: OSTDS New APPLICANT: (Standard Pacific of Florida GP Inc.) PROPERTY ADDRESS: 3001 NW Radcliffe Way Port Saint.Lucie, FL 34952 LOT: 47 BLOCK: SUBDIVISION: Riverbend PERMIT # : 56-S F-1529657 APPLICATION #:AP1141186 DATE PAID: FEE PAID: RECEIPT #: DOCUMENT #: PR934752 PROPERTY ID #: 4425-703-0052-000-4 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT "EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY, SYSTEM DESIGN AND SPECIFICATIONS T [ 1,350 ] GALLONS / GPD Septic CAPACITY A [ ] GALLONS / GPD N/A CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS 0[ ]DOSES PER 24 HRS •#Pumps [ ] D [ 867 ] SQUARE FEET Bed SYSTEM R [ ] SQUARE FEET N/A SYSTEM .A TYPE SYSTEM: [ ] STANDARD [ ] FILLED [x] MOUND I CONFIGURATION: [ ] TRENCH [x] BED [] N _F LOCATION OF BENCHMARK: Top Of Catch Basin Ne Corner I ELEVATION OF PROPOSED SYSTEM SITE [ 23.001[ INCHES FT ][ ABOVE BELOW] BENCHMARK/REFERENCE POINT L E BOTTOM OF DRAINFIELD TO BE [ 23.001 INCHES FT ][ ABOVE BELOW]BENCHMARK/REFERENCE POINT DI --- -- 0 T H E R W �-- _YUincu: Llb.00] INCHES EXCAVATION REQUIRED: [ ] INCHES The system is sized for 5 bedrooms with a maximum occupancy of 10 persons (2 per bedroom), for a total estimated flow of 520 gpd. The licensed contractor installing the system is responsible for installing the minimum category of tank in accordance with s. 64E-6.013(3)(0, FAC. SPECIFICATIONS BY: Andrew R Gatewood TITLE: Environmental Specialist II APPROVED BY: TITLE: Environmental Specialist II Andrew R Gatewood DATE ISSUED; 03/31/2014 P..XDTD21mTnXT n�M. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, PAC v 1.1.4 AP1141186 SE924280 St. Lucie CHD 09/3012015 Page 1 of 3 NOTICE OF RIGHTS A party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the Department, within twenty-one (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way, BIN # A02, Tallahassee, Florida 32399-1703. The Agency Clerk's facsimile number is 850-410-1448. Mediation is not available as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative hearing, and this order shall become a'final order'. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order.