Loading...
HomeMy WebLinkAboutM Energy Calcsz g - o DlJMMFL RESz77FNCE O ° LOT 64 v zo Bl-11— � m NETTLES ISLAND 57 LUCIE COUNTY FLORIDA � oEsieN seA�mcs. uuc - o�seu i enarnuc I ccusuu� iue FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: DUHAMEL RESIDENCE Builder Name: Street: LOT 64 NETTLES ISLAND Permit Office: ST LUCIE COUNTY City, State, Zip: JENSEN BEACH , FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type�2452.0 sqft.) Insulation Area 2. Single family or mulUpte family Detached a. Concrete Block - Polystyrene Bead Aggr9R=5.0 2236.00 W b. Frame - Wood, Adjacent R =11,0 216.00 W 3. Number of units, if multiple family 1 c. N/A R= Z 4. Number of Bedrooms g d. N/A ft R= ft2 5. Is this a worst case? No 11. Ceiling Types (2575.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=19.0 2575.00 W 5. Conditioned floor area above grade (ft2) 2575 b. N/A R= ft2 Conditioned floor area below grade (a2) 0 c. NIA R= ft2 7. Windows(320.9 sqft.) Description Area 12-Ducts R ft2 a. U-Factor. Sgl, U=D.65 267.60 ft2 a. Sup. Attic, Ret. Attic, AH: AHU CLST 6 175 SHGC: SHGC=0.25 b. U-Factor. Sgl, U=0.65 53,33 fe 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 41.0 SEER:16.00 c. 1-1-Factor: NIA fta SHGC: Area Weighted Average Overhang Depth: 1.720 ft. 14. Heating systems kBtulhr Efficiency Area W eighted Average SHGC: 0.258 a. Electric Strip Heat 27.0 COP.1.00 8, Skylights Area c. U-Factor:(AVG) WA ft= 15, Hat water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (2575.0 sqft,) Insulation Area EF: 0.980 a. Raised Floor R=19.0 144a.00 ft' b. Conservation features b. 51ab-On-Grade Edge Insulation R=0.0 1127.00 ft2 None c. N/A R= ft2 16. Credits None Glass/Floor Area; 0.125 Total Proposed Modified Loads: 74.84 PASS Total Baseline Loads: 79.58 1 hereby certify that the plans and specifications covered by Review of the plans and r SfigT this calculation are in compliance with the Florida Energy Code, specifications covered by this a16 fl calculation indicates compliance„ with the Florida Energy Code. PREPARED BY:guL Before construction is completed w DATE: 3-16-2021 this building will be inspected for 0 compliance with Section 553.908 I hereby certify that this buildin as designed, is in compliance Florida Statutes. with the Florida Energy Cod C'01) W-C OWNER/AGENT.- BUILDING OFFICIAL: DATE: `"� DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 3/16/2021 10:09 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: DUHAMEL RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2575 Lot # Owner Name: Total Stories: 1 BlocklSuhdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: LOT 64 NETTLES ISLA Permit Office. ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: JENSEN BEACH , Family Type: Detached FL , NewlExisting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 9 Entire House 2575 20600 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 FOYER 74 592 No 0 1 Yes Yes Yes 2 W IC 1 ST FLR 26 208 No 0 1 Yes Yes Yes 3 LINEN CLST 14 112 No 0 1 No Yes Yes 4 DEN 112 896 No 0 1 Yes Yes Yes 5 LIVING RM 228 1824 No 0 1 Yes Yes Yes 6 DINING 272 2176 No 0 1 Yes Yes Yes 7 BATH 65 520 No 0 1 Yes Yes Yes 8 KITCHEN 336 2688 Yes 0 1 Yes Yes Yes 9 M WIC 112 896 No 0 1 Yes Yes Yes 10 LAUNDRY RM 40 320 No 0 1 Yes Yes Yes 11 BATH 2 45 360 No 0 1 Yes Yes Yes 12 CHANGING RM 36 288 No 0 1 No Yes Yes 13 M TOILET 20 160 No 0 1 No Yes Yes 14 M BATH 119 952 No 0 1 Yes Yes Yes 15 M CLST 16 128 No 0 1 No Yes Yes 16 HALL 131 1048 No 0 1 No Yes Yes 17 STAIRS UP 57 456 No 0 1 Yes Yes Yes 18 AHU CLST 13 104 No 0 1 No Yes Yes 19 BATH 3 60 480 No 0 1 Yes Yes Yes 20 BEDROOM 2 163 1304 No 0 1 1 Yes Yes Yes 21 CLST 2 18 144 No 0 1 Yes Yes Yes 22 BEDROOM 3 168 1344 No 0 1 1 Yes Yes Yes 3/16/2021 10:09 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT S11MMAPY rWFrl<i JQT Q1:pnQT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 23 WIC 3 25 200 No 0 1 Yes Yes Yes 24 MASTER BEDROO 425 3400 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation FOYER 8 ft 74 ft' -___ 1 0 0 2SIab-On-Grade Edge Insulation WIC 1ST FLR 10.4 ft 26 fe ____ 1 0 0 3 Slab -On -Grade Edge Insulation LINEN CLST 1 ft 14 ft2 ____ 1 0 0 4 S€ab-On-Grade Edge Insulation DEN 13.8 ft 112 ft2 ____ 1 0 0 5Slab-On-Grace Edge Insulation LIVING RM 35.8 ft 228 ft2 -___ 1 0 0 6 Slab -On -Grade Edge Insulation DINING 12 ft 272 W _-__ 1 0 0 7 Slab -On -Grade Edge Insulation BAT" 5.1 ft 65 fe __-- 1 0 0 8 Slab -On -Grade Edge Insulation KITCHEN 36.1 ft 336 ft' ____ 1 0 0 9 Raised Floor M W IC ____ --_- 112 ft2 19 1 0 0 10Raised Floor LAUNDRY RM _--_ _--_ 40 ff 19 1 0 0 11Raised Floor BATH 2 _-__ _-__ 45 ft2 19 1 0 0 12Raised Floor CHANGING RM ____ _ 36 fe 19 1 0 0 13Raised Floor M TOILET _-_- _-__ 24 ft2 19 1 0 0 14Raised Floor M BATH -___ --__ 119 ft2 19 1 0 0 15Raised Floor M CLST --__ _-__ 16 ft2 19 1 0 0 16Raised Floor HALL _-_- _-__ 131 ft2 19 1 0 0 17Raised Floor STAIRS UP _-__ __-_ 57 ft' 19 1 0 0 18Raised Floor AHU CLST --__ __-- 13 ft2 19 1 0 0 19Raised Floor BATH 3 _-__ ____ 60 ft2 19 1 0 0 20Raised Floor BEDROOM 2 _-__ -___ 163 fe 19 1 0 0 21Raised Floor CLST 2 _-__ ___- 18 W 19 1 0 0 22Raised Floor BEDROOM 3 --__ __-_ 168 ft2 19 1 0 0 23Raised Floor WIC 3 _-__ -___ 25 ft2 19 1 0 0 24Raised Floor MASTER BEDRO ---- -___ 425 ft2 19 1 0 0 3/16/2021 10:09 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2654 ft2 0 ft' Light N 0.2 No 0.9 No 19 14.04 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2575 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) FOYER 0 Blown 74 ft2 0.1 Wood 2 Under Attic (Unvented) WIC 1ST FLR 0 Blown 26ft2 0.1 Wood 3 Under Attic (Unvented) LINEN CLST 0 Blown 14 W 0.1 Wood 4 Under Attic (Unvented) DEN 0 Blown 112 ft2 0.1 W cod 5 Under Attic (Unvented) LIVING RM 0 Blown 228 W 0.1 Wood 6 Under Attic (Unvented) DINING 0 Blown 272 W 0.1 Wood 7 Under Attic (Unvented) BATH 0 Blown 65 ft2 0.1 Wood 8 Under Attic (Unvented) KITCHEN 0 Blown 336 ft2 0.1 Wood 9 Under Attic (Unvented) M WIC 0 Biown 112 ft2 0,1 Wood 10 Under Attic (Unvented) LAUNDRY RM 0 Blown 40 ft2 0.1 Wood 11 Under Attic (Unvented) BATH 2 0 Blown 45 ft2 0.1 W ood 12 Under Attic (Unvented) CHANGING RM 0 Blown 36 ft2 0.1 Wood 13 Under Attic (Unvented) M TOILET 0 Blown 20 ft2 0.1 Wood 14 Under Attic (Unvented) M BATH 0 Blown 119 ft2 0.1 Woad 15 Under Attic (Unvented) M CLST 0 Blown 16 ft2 0.1 Wood 16 Under Attic (Unvented) HALL 0 Blown 131 ftz 0.1 Wood 17 Under Attic (Unvented) STAIRS UP 0 Blown 57 ft2 0.1 Woad 18 Under Attic (Unvented) AHU CLST 0 Blown 13 ft2 0.1 Wood 19 Under Attic (Unvented) BATH 3 0 Blown 60 ft2 0A Wood 20 Under Attic (Unvented) BEDROOM 2 0 Blown 163 W 0.1 Wood 21 Under Attic (Unvented) CLST 2 0 Blown 18 ft2 0.1 Wood 22 Under Attic (Unvented) BEDROOM 3 0 Blown 168 ft2 0.1 Wood 23 Under Attic (Unvented) WIC 3 0 Blown 25 ft2 0.1 Wood 24 Under Attic (U nvented) MASTERBFDRO 0 Blown 425ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belowo Space 1 S Exterior Concrete Block - PolystyrenBOYER 5 8 0 8 0 64.0 ft2 0 0 0.2 0 2 W Garage Frame - Wood FOYER 11 10 0 8 0 80.0ft2 0 0.1 0.2 0 i 3 SE Exterior Concrete Block - Poiysty WG 1ST FLR 5 4 3 8 0 34.0 ft2 0 0 0.2 0 4 S Exterior Concrete Block - PolystyVIMQ 1ST FLR 5 4 0 8 0 32.0 ft2 0 0 0.2 0 5 SW Exterior Concrete Block - PolystMtG 1ST FLR 5 2 3 8 0 18.0 ft2 0 0 0.2 0 3/16/2021 10:09 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS �z Ornt Adjacent Tn Space Wall Type Cavity Width Height Sheathing Framing Solar Below 0 it 6 SE Exterior Concrete Block - PolystyreneDEN 5 13 11 8 0 111.3 ft2 0 0 0.2 0 7 N Exterior Concrete Block - Polystyr6iVING RM 5 21 0 8 0 168.0 ft2 0 0 0.2 0 8 SE Exterior Concrete Block - Polystyr&AVING RM 5 14 9 8 0 118.0 ft2 0 0 0.2 0 9 N Exterior Concrete Block - Polystyren®INING 5 12 0 8 0 96.0 ft2 0 0 0.2 0 10 W Exterior Concrete Block - PoiystyrenfBATH 5 5 1 8 0 40.7 ft2 0 0 0.2 0 11 S Garage Frame - Wood BATH 11 12 0 8 0 96.0 €t2 0 0.1 0.2 0 12 N Exterior Concrete Block- PolystyreK&TCHEN 5 21 0 8 0 168.0 ft2 0 0 0.2 0 13 W Exterior Concrete Block - PolystyreKd�TCHEN 5 15 2 8 0 121.3 ft2 0 0 0.2 0 14 SW Garage Frame - Wood KITCHEN 11 5 0 8 0 40.0 ft2 0 0.1 0.2 0 15 N Exterior Concrete Block - PolystyrenAl WIC 5 9 0 8 0 72.0 ft2 0 0 0.2 0 16 W Exterior Concrete Block - Polystyren(t WIC 5 13 2 8 0 105.3 ft2 0 0 0.2 0 17 N Exterior Concrete Block- PolystydeADNDRY R 5 6 0 8 0 48.0 ft2 0 0 0.2 0 18 N Exterior Concrete Block - Polystyreni3ATH 2 5 5 0 8 0 40.0 ft2 0 0 0.2 0 19 W Exterior Concrete Block - Polystyrerfid BATH 5 10 2 8 0 81.3 ft2 0 0 0.2 0 20 SE Exterior Concrete Block - Polystyr&Te'11RS UP 5 5 10 8 0 46.7 ft2 0 0 0.2 0 21 ' SE Exterior Concrete Block - Polystyren®ATH 3 5 12 6 8 0 100.0 ft2 0 0 0.2 0 22 N Exterior Concrete Block - PolystyfEt7ROOM 2 5 11 0 8 0 88.0 ft2 0 0 0.2 0 23 N Exterior Concrete Block - PolystyrentiLST 2 5 2 0 8 0 16.0 ft2 0 0 0.2 0 24 N Exterior Concrete Block - Polysty&fif]ROOM 3 5 10 0 8 0 80.0 ft2 0 0 0.2 0 25 SE Exterior Concrete Block - Polystyf&EDROOM 3 5 8 11 8 0 71.3 €t2 0 0 0.2 0 26 N Exterior Concrete Block - PolystyrenEVV iC 3 5 6 0 8 0 48.0 ft2 0 0 0.2 0 27 SE Exterior Concrete Block - Polystyrend/VIC 3 5 6 8 8 0 53.3 ft2 0 0 0.2 0 28 ' SE Exterior Concrete Block - PoiystydTER BE 5 13 5 8 0 107.3 ft2 0 0 0.2 0 29 S Exterior Concrete Block - PoiystydTER BE 5 19 0 8 0 152.0 ft2 0 0 0.2 0 30 W Exterior Concrete Block - Polystyrldfi6TER BE 5 19 5 8 0 155.3 ft2 0 0 0.2 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SW Insulated WIC 1ST FLR None .19 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation Wall Overhang J # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int. Shade Screening 1 S 1 Vinyl Low-E Single Yes 0.65 0.25 Y 8.9 ft2 9 ft 0 in 1 ft 4 in None None 2 S 1 Vinyl Low-E Single Yes 0.65 0.25 Y 20.0 ft2 9 ft 0 in 1 ft 4 in None None 3 SE 6 Vinyl Low-E Single Yes 0.65 0.25 Y 10.0 ft2 1 ft 0 in 1 ft 4 in None None J 4 N 7 Vinyl Low-E Single Yes 0.65 0.25 Y 20.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 5 SE 8 Vinyl Low-E Single Yes 0.65 0.25 Y 10.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 6 SE 8 Vinyl Low-E Single Yes 0.65 0.25 Y 10.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 7 N 9 Vinyl Low-E Single Yes 0.65 0.3 Y 53.3 W 1 ft 0 in 1 ft 4 in None None 8 W 10 Vinyl Low-E Single Yes 0.65 0.25 Y 5.8 ft2 1 ft 0 in 1 ft 4 in None None 9 W 13 Vinyl Low-E Single Yes 0.65 0.25 Y 9.0 ft2 1 ft 0 in 1 ft 4 in None None 31l6/2021 10:09 AM EnergyGauge� USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST RFPORT WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Ornt I❑ Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 10 11 12 13 14 15 16 W 18 19 W 16 Vinyl N 18 Vinyl W 19 Vinyl SE 20 Vinyl N 22 Vinyl N 24 Vinyl SE 25 Vinyl S 29 Vinyl W 30 Vinyl W 30 Vinyl Low-F Single Low-F Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-F Single Low-E Single Low-E Single Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.65 D.25 Y 7.4 ft' 1 ft 0 in 0.65 0.25 Y 6.0 ft' 1 ft 0 in 0.65 0.25 Y 12.0 ft' 1 ft 0 in 0.65 0.75 Y 23.5 ft' 1 ft 0 in 0.65 0.25 Y 15.0 ft' 1 ft 0 in 0.65 0.25 Y 15-0 ft' 1 ft 0 in 0.65 0.25 Y 15.0 ft' 1 ft 0 in 0.65 0.25 Y 60.0 ft2 1 ft 0 in 0.65 0.25 Y 9.6 ft' 1 ft 0 in 0.65 0.25 Y 10.0 ft2 1 ft 0 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in None None None None None None None None None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 280 ft' 2B0 W 27 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 FLA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1716.7 94.18 176.62 .0902 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat] None COP:1 27 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 41 kBtulhr 1230 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name System Model # Collector Model # Collector Area Storage Volume FFF None None ft' 3/16/2021 10:09 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SiJMMARY CHFr 1<1 [CT RFpnRT DUCTS / ---- Supply---- ---- Return ---- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 175 ft2 Attic 18 ft2 Default Leakage AHU CLST (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Coolin r Jan Heating {X� Jan Feb Feb Mar Apr Mar � A r f Ma May Jun Jun ri Jul Jul X Au AuSep X Se Oct Oct Nov Nov Dec] X] Dec Ventin [[ Jan Feb Mar A r [ Ma Jun Jul [ Aug [ Se LX [ Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WFH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (VVEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 FOYER Default(8lbs/sq.ft. ft2 ft 0.3 WIC 1ST FLR Default(8 lbslsq.ft. W ft 0.3 LINEN CLST Default(& Ibs/sq.ft. ft2 ft 0.3 DEN Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING RM Default(8 lbslsq.ft. ft2 ft 0.3 DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH Default(8 Ibslsq.ft. ft2 ft 0.3 KITCHEN Default(8lbslsq.ft. ft2 ft 0.3 M WIC Default(8 Ibslsq.ft. ft2 ft 0.3 LAUNDRY RM Default(8 Ibslsq.ft. ft, ft 0.3 BATH 2 Default(8lbslsq.ft, ft2 ft 0.3 CHANGING RM Default(8 Ibslsq.ft, ft2 ft 0.3 M TOILET Default(& Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibslsq.ft. ft2 ft 0.3 M CLST Default(8 Ibslsq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 STAIRS UP Default(8 Ibslsq.ft. ft2 ft 0.3 AHU CLST Default(8 Ibslsq.ft, ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft, ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8lbs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO 3/16/2021 10:09 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 7 of 7 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (W) 7. Windows** Description a. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 SHGC: SHGC-0.30 c. U-Factor: N/A SHGC: d. U-Factor: NIA SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): NIA SHGC(AVG): NIA 9. Floor Types a. Raised Floor b. Slab -On -Grade Edge Insulation c. N/A LOT 64 NETTLES ISLAND, JENSEN BEACH, FL, New (From Plans) Detached 1 3 No 2575 Area 267.60 W 10. Wall Typeand Insulation Insulation a. Concrete Block - Polystyrene Bead AggrER=5.0 b. Frame - Wood, Adjacent R=11.0 c. NIA R= d. WA R= 11. Ceiling Type and insulation level Insulation a. Roof Deck (Unvented) R=19.0 b. NIA R= c. N!A R= 12. Ducts, location & insulation level a. Sup: Attic, Rot: Attic, AH: AHU CLST 53.33 ft2 13. Cooling systems W a. Central Unit ft2 1.720 ft. 0.258 Area ft2 Insulation Area R=19.0 1448,00 W R=0.0 1127.00 f12 R= ft2 14. Heating systems a. Electric Strip Heat 15. Hot water systems a Electric b. Conservation features None Credits (Performance method) certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspeA�tion. Otherwise, a new EPL Display Card will be completed based on installed Code corVDfiant features,, Builder Signature: Address of New Home: Date a City/FL Zip:fJ,`���� Area 2236.00 f12 216.00 ft2 ft2 ft2 Area 2575.00 ft2 fe ftz R ft2 6 175 kBtulhr Efficiency 41.0 SEERA6.00 kBtulhr Efficiency 27.0 COP:1.00 Cap: 50 gallons EF: 0.98 4 WV - None *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/16/2021 10:10 AM EnergyGauge® USA 7.0.00 - FiaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 + - wrightsoW Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALGS@AOL.COM ! i ! For: DUHAMEL RESIDENCE LOT 64 NETTLES ISLAND, JENSEN BEACH, FL External static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual air flaw Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.5001 0.500 in H2O 1.000 in/ 1 00ft 1367 cfm Job: Date: Mar 16,2021 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.5001 0.500 in H 20 1.000 in1100ft 1367 cf m 182 ft Supply Bra h Detail Table . Name Design (Btuh) Htg {cfm) CIg (cfm) Design FR Diam (in) H x W (in) Duct Mat] Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH c 1151 30 51 1.000 6.0 Ox0 VIFx 19.7 155.0 sty BATH 2 h 455 21 15 1.000 4.0 Ox 0 Vl Fx 27.9 135.0 st4 BATH 3 h 761 34 20 1.000 5.0 Ox 0 VIFx 16.0 115.0 st 1 BEDROOM 2 c 2168 59 96 1,000 7.0 Ox0 VIFx 16.7 115.0 st1 BEDROOM 3 c 2203 89 98 1.000 7.0 Ox0 VIFx 13.6 115.0 st1 CHANGING RM h 76 3 3 1.000 4.0 Ox0 VIFx 26-0 135.0 st4 DEN c 2268 71 101 1.000 7.0 Ox 0 VIFx 12.7 155.0 st6 DINING c 2808 103 125 1.000 7-0 Ox0 VIFx 20.6 155.0 st5 FOYER c 1543 62 69 1.000 6.0 Ox0 V]Fx 21.7 155.0 st5 KITCHEN h 3864 175 149 1.000 8.0 Ox 0 VIFX 27.4 155.0 st5 LAUNDRY RM c 1105 17 49 1.000 6.0 OX 0 VIFx 27.9 135.0 st4 LIVING RM h 4358 197 151 1.000 8.0 0x 0 VIFx 13.1 155.0 st6 M BATH c 1341 46 60 1.000 6.0 Ox 0 VIFx 20.7 115.0 st2 •TOILET h 66 3 3 1.000 4.0 Ox0 VIFx 24.9 135.0 st4 • WIC h 1440 65 56 1,000 6.0 Ox0 VIFx 32.9 135.0 st4 MASTER BEDROOM In 3014 136 114 1.000 7.0 0x0 VIFx 17.5 115.0 st2 MASTER BEDROOM -A h 3014 136 114 1.000 7.0 Ox 0 VIFx 12.1 115.0 st2 STAIRS UP c 1363 43 61 1.000 6.0 Ox0 VIFx 16.8 115.0 st2 WIC 1STFLR h 1027 46 11 1.000 4.0 Ox0 VIFx 26.9 155.0 st5 WIC 3 h 657 30 22 1.000 5-0 Ox0 VIFx 2C.6 115.0 SO wrightsc)ft- 2021-Mar-16 09:29:10 •. : _ ^• Right -Suite) Universal 2021 21.0.02 RSU081C1 Page 1 -0C'k Ea.Documnets\Wrightseft HVAC1DUHAMEL RESIDENCE rup Calc = MJ8 Front Door faces: S Supply TTu�k Qetaif Table Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk sty Peak AVF 416 405 1.000 763 10.0 0 x 0 VinlFlx st3 st6 Peak AVF 268 252 1.000 607 9.0 0 x 0 VinlFlx st3 st3 Peak AVF 684 657 1.000 871 12.0 0 x 0 VinlFlx st1 Peak AVF 212 237 1.000 536 9.0 0 x 0 VinlFlx st4 Peak AVF 109 125 1.000 469 7.0 0 x 0 VinlFlx st2 st2 Peak AVF 470 473 1.000 602 12.0 0 x 0 VinlFlx Retur>1 Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb 1 Ox 0 1367 1367 0 0 0 0 Ox 0 V I Fx wrightsaft- 2021-Mar-16 09:29:10 t Iu��•.,.��... �F�f.»•.« ., Right-SulteAe7 Universal 2021 21.0.02 RSUG8101 Page 2 E:1DooumnetslWrightsoft RVAMDURAMEL RESIDENCE_rup talc = MJ8 Front Door faces: S Project Summary Job: wrightsoft , Entire House Date: Mar 16, 20a� QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466.6796 Email: OUICKCALCS@ACL.COM ` •dbtlfformation For: DUHAMEL RESIDENCE LOT 64 NETTLES ISLAND, JENSEN BEACH, FL Notes: InfOrmation, Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 'F Design TD 28 OF Design TD 15 'F Daily range M Relative humidity 50 % Moisture difference 61 grub Heating Summary Sensible Cooling Equipment Load Sizing Structure 22653 Btuh Structure 20042 Btuh Ducts 7584 Btuh Ducts 10673 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30238 Btuh Use manufacturer's data n Rate/swing multiplier Equipmenf 0.95 Infiltration sensible load 29180 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4295 Btuh Ducts 2988 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling Area (none) (fitz) 2575 2575 Equipment latent load 7283 Btuh Volume (W) 20600 20600 Air changes/hour 0.32 0.16 Equipment Total Load (Sen+Lat) 36462 Btuh Equiv- AVF (cfm) 110 55 Req. total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANS Model Cond 4TTR6042J 1 AHRI ref Coil TEM4AOC42S41++TDR AHRI ref 8703699 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 7.9 kW Sensible cooling 28700 Btuh Heating output 26892 Btuh Latent cooling 12300 Btuh Temperature nse 18 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.045 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wrigksfsolFt" 2021-Mar-16 09:29:01 '^""""""""'¢" Right -Suite® Universal 2021 21.0.02 RSUO8101 �` E:1DooumnetslWrightsoft HVACIDUHAMEL RESIDENCE_rup Calc = MJ8 Froni Door faces: S Page 1 wrightsoft' Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A66-6799 Fax 772-466-6796 Email: QUICKCALCs@,AAL.COM Entire House 1 Room name 279.0 ft 2 Exposed wall 8.0 ft 3 Room height 4 Room dimensions 2574.9 ft2 5 Room area Ty Construction U-value Or °F) HTM (Btuhlft2) Area (ft2) or perimeter (ft) Load (Btuh) number (Btuhlft= Heat Coal Gross N/P/S Heat Cool 6 13A-5fcs 0,105 n 2.94 1.61 824 6 714 0 2100 1148 109 90 2 glazing, cir low-e 0,650 n 0.850 n 18.20 18.20 14.99 14.99 30 0 54b 450 2 glazing, cir low-e 2 glazing, cir low-e 0.650 n 18.20 14,99 54 0 976 364 804 214 11 2 glazing, clr Icw-e 0.650 n 18.20 2.94 10.68 1.61 20 643 0 574 1687 922 13A 5fcs 2 glazing, cir low-e 0.105 se 0.650 se 18.20 25.63 10 1 182 56 384 84 2 glazing, cir low-e 0.650 se 18.20 25.63 15 2 2 273 428 608 2 glazing, cir low-e 0.650 se 18.20 25.86 24 10 1 182 166 2 glazing, cir low-e 0.650 se 18.20 18.20 16.62 16.62 10 1 190 173 2 giazinq, cir low-e 13A 5fcs 0.650 se 0.105 s 2.94 1.61 248 159 467 255 899 2 glazing, cir low-e 0.650 s 18.20 14.99 60 60 9 1092 163 134 2 glazing, cir low-e 0.650 s 0.650 s 18.20 18.20 14.99 14.99 9 20 20 366 301 2 glazing, cir lcw-e W 13A-5fcs 0.105 sw 2.94 1.61 18 18 53 29 723 13A 5fcs 0.105 w 2.94 1.61 504 7 450 0 1324 134 249 2 glazing, cir low-e 0.650 w 18.20 33.77 6 0 106 197 2 glazing, cir low-e 0.650 w 18.20 33.77 9 0 164 304 2 glazing, clrlow-e 0.650 w 0.650 w 18.20 18.20 33.77 33.77 12 0 218 405 2 glazing, clr low-e 2 glazing, cir Saw-e 0.650 w 18.20 33.77 10 0 174 324 338 2 glazing, cir low-e 0.650 w 18.20 1.59 33.77 1.37 10 1545 0 1545 182 2449 2114 C 16X19-0md F 22A-tph 0.408 1.358 38.02 0.00 1256 141 5344 0 6 c)AED excursion Envelope loss/gain 12 a) Infiltration b) Room ventilation 13 Internal gains: Subtotal (lines 6 to 13) Less external load Less transfer Redistribution 14 Subtotal 15 Duct loads Total room load A r required (cfm) Job: Date: Mar 16,2021 By: FOYER 8.0 ft 8.0 ft heaticool 1.0 x 75.5 ft 75.5 ft2 Area (W) Load or perimeter (ft) (13tuh) Gross N/PIS Heat Cool 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 64 35 103 56 0 0 0 0 9 9 163 134 20 20 366 301 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 76 8 304 0 0 -11 19272 11487 935 481 3381 906 97 26 0 0 0 0 Occupants @ 230 0 7650 0 D Appliancestother 22653 20042 1032 1007 0 0 0 0 0 0 0 0 0 0 0 0 22653 20042 1032 1007 33% 53% 7584 10673 33°l0 53% 346 536 30238 30715 1378 1543 1367 1367 62 69 Calculations approved b ACCA to meet all.requirements of Manual J 8ttl Ed. 2021-Mar-16 09:29:01 _ - wrgril-atsoft" °•FtighY-Suite® Un9versal 2421 21.0.02 RSU08101 Page 1 AG�A E:0ocumnets\Whghts0ft HWACIDUHAMEL RESIDENCE.rup Calc = MJ6 Front Door faces: S -- wr,ghtsoft° Right-J® Worksheet Job: Entire House Date: Mar 16, 2021 B y: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-46"799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-16 09,29:01 Right -Suite@ Universal 2021 21.0,02 RSU08101 Page 2 lot& E:1Documnets\Wrightsoft HVACIDUHAMEL RESIDENCE.rup Calc = MJS Front Door faces: S wrightsoft Ri9 ht-M Worksheet Job: 16, 2021 . Enure House Date: Mar By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phcne: 772-466-6799 Fax: 772-466-6796 Email: QUI C KCALC S@AOL. C OM 1 Room name DEN LIVING RM 2 Exposed wall 3 Room height 8.0 ft 13.8 ft heat/cool 8.0 ft 35.8 ft heat/cool 4 Room dimensions 1.0 x 112.0 ft 1.0 x 227.5 ft 5 Room area 112.0 ft2 227.5 ft2 Ty Constriction number U-value Or HTM (Btuhlft? °F) (Btuhlft=) Area (ft') or perimeter (ft) Load (Btuh) Area (tt2) or perimeter (ft) Load (Btuh) Neat Cool Gross N/P/S Heat Cool Gross NIPIS Heat Cool 6 13A-5fcs 0.105 n 2.94 1.61 0 0 0 0 168 14$ 0 435 0 238 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18-20 14.99 0 0 0 0 0 0 2 glazing, clr low-e 0,650 n 18.20 14.99 0 0 0 0 0 0 0 0 20 0 0 0 364 214 11 2 glazing, clr low-e 13A 5fcs 0.650 n 18.20 0.105 se 2.94 10.68 1.61 0 111 101 297 162 118 98 287 157 2 glazing, clr low-e 0.650 se 18.20 25-63 10 1 182 256 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 se 18.20 25.63 0 0 0 0 0 0 2 glazing, clr low-e 0.650 se 18.20 25.86 0 0 0 0 a 0 0 10 0 1 0 182 166 2 glazing, clr low-e 0.650 se 18.20 16.62 0 0 0 10 1 190 173 2 alazinq. clr low-e 0,650 se 18.20 16.62 0 0 0 0 0 0 0 13A-5fcs 0-105 s 2.94 1.61 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 2 glazing, clr low-e 0.650 s 18,20 14.99 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 W 13A-5fcs 0.105 sw 2.94 1.61 0 0 0 0 0 0 0 0 0 0 13A-5fcs 0.105 w 2.94 1.61 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 0 0 2 glazing, c!r low e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, ctr tow-c 0,650 w 15.20 33.77 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18-20 33.77 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 16.20 33.77 0 0 0 0 10 10 15 13 C 16X19-Omd F 22A-tph 0.408 1.59 1.358 38.02 1.37 0.00 3 112 3 14 4 526 4 0 228 36 1359 0 12 -65 6 c)AED excursion Envelope loss/gain 1010 435 2833 896 12 a) Infiltration 168 45 433 0 116 0 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 p 0 1200 Applianceslother loco Subtotal (lines 6 to 13) 1178 1480 3265 2212 Less external load 0 0 0 0 0 0 0 0 Less transfer 0 O 0 0 Redistribution 1178 1480 3265 2212 14 Subtotal 33% 53% 394 788 33% 53% 1093 1178 15 Duct loads Total room load 1572 71 2268 101 4358 1971151 3390 Asf required (cfm) Calculations approved b ACCA to meet all requirements of Manual J 8th Ed. wr-syrri tsolt 2021-Mar-16 09:29:01 Right -Suited Universal 2021 21.0.02 RSU08101 Page 3 ' � E:1DocumnetslWrightsoft HVACIDUHAMEL RESIDENCE.rup Calc = MJB Front Door faces: S +- wrightsoft Right-JO Worksheet Job: Entire House Date: Mar 16, 2021 QUICK CALCS, INC, By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Roam name Fxposed wall Room height Room dimensions Room area DINING 12.0 ft 8.0 ft heat/cool 1.0 x 272.0 ft 272.0 ft' BATH 5.1 ft 8.0 ft heaticool 1.0 x 64.5 ft 64.5 f? Ty Construction number U-value (Btuhlft2 "F) Or HTM (Btuhlftz) Area (ft) or perimeter (ft) Load (Btuh) Area (ft-) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Grass NIP/ 5 Heat I Cool 6 11 13A-5fcs 2 glazing, clr low-e 2 glazing, clr low-.0.650 2 glazing, clr low-o 2 glazing, clr low-e 13A 5fcs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazinq, & low-e 13A 5fcs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-. 13A-5fcs 13A-5fcs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 16X19-Omd 22Atph 0.105 0.650 0.650 0.650 0.105 0.650 0.650 0.650 0.650 0.650 0. 0.650650 0.650 0.650 0.105 0.105 0,650 0,650 0.650 0.650 0.650 0.650 0.408 1,358 n n n n n se se se se se se s s s s sw w w w w w w w 2.94. 18.20 18.20 18,20 18.20 2.94 18.20 18.20 18.20 18.20 18.20 . 188.2020 18.20 M20 2.94 2.94 18.20 18,20 18.20 18.20 18.20 18.20 1.59 38.02 1.61 14.99 14.99 14.99 10.68 1.61 25.63 25.63 25.86 16.62 16.62 1.61 94,99 14.99 14.99 1.61 1.61 33.77 .33.77 33.77 33.77 33.77 33.77 1.37 0.00 96 0 0 54 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 272 42 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12 125 0 0 976 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 456 68 0 0 804 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 41 0 • 6 0 0 0 0 22 65 0 0 0 0 0 0 0 0 0 0 0 0 D 0 0 0 35 0 0 0 0 0 0 22 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 103 0 106 0 0 0 0 35 193 p p 0 0 0 0 0 0 0 0 0 0 0 0 0 0 56 0 197 0 0 0 0 30 0 1r! w G F 6 c)AED excursion -78 51 Envelope Iosslgain 1556 794 437 334 12 a) .Infiltration 145 39 62 17 b) Room vantilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancesiother 1000 400 Subtotal (lines 6 to 13) 1702 1832 499 751 Less edemal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 1702 0 0 1332 0 0 499 0 0 751 15 Duct loads 33'% 53% 570 976 33% 53% 167 400 Total room load Ar required (cfm) 2271 103 2805 125 T666 30 1151 51 _ Calculations approved byACCA to meet all requirements of Manual J 8th Ed. WrigFwtsoft 2021-Mar-16 09:29:01 Right -Suited Universal 2021 21.0.02 RSU08101 Page 4 E:1DocumneWWrightsott HVACIDUHAMEL RESIDENCE.rup Calc =M-18 Front Door faces: S + wrightsatt, Right-JO Worksheet Date: Mar 1s, zo21 Entire House QUICK CALCS, INC. By 317 ST LUCIE LANE, FORT PILRCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: RUICKCALCS@AOLCOM 1 Room name KITCHEN M WIC 2 3 Exposed wall Room height 9 36.1 ft 8.0 ft heat/cool 22.1 ft 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 336.0 ft 336.0 ft' 1.0 x 1111.8 ft 111.8 ft, Ty Construction J-}slue Or HTM Area (w) Load Area (ft2) Load number (Btuh/11`11:221F) (Btuhlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIPIS Heat Cool Gross N/l Heat Ccol 6 13A-5fcs 2 glazing, clr lower 2 glazing, clr low-e 0.105 0.650 0.650 n n n 2.94 18.20 18.20 1.61 14.99 14.99 168 0 0 168 0 0 494 0 a 270 0 0 72 0 0 72 0 0 212 0 a 116 0 0 11 2 glazing, clr low-e 2 glazing, clr low-e 0.650 0.650 n n 18.20 18.20 14.99 10.68 0 D 0 0 0 0 C 0 0 0 0 0 0 0 0 0 13A-5fcs 2 glazing, cir low-e 2 glazing, clr low-e 0.105 0.650 0.650 se se se 2.94 18.20 18.20 1.61 25.63 25.63 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a 0 0 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 0.650 0.650 se se 18,20 18-20 25.86 16.62 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 alazina, clr low-e 2 glazing, c{r low-e 2 glazing, 0.650 0,650 0.850 se s s 18.20 2.94 18.20 16.52 1.61 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 L-� 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 a 0 0 0 0 W 13A-5fcs 13A-5fcs 0.105 0.105 sw w 2.94 2.94 1.61 1.61 0 121 0 112 0 329 0 180 a 105 a 98 0 266 0 157 2 glazing, clr low-e 0,650 w 18.20 33.77 D 0 0 0 7 0 134 249 2 glazing, cir low-e 2 glazing, Or low-e 2 glazing, Or low-e 0.650 0.650 0.650 w w w 18.20 18.20 18.20 33.77 33.77 33.77 0 9 0 0 0 0 0 164 0 0 304 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, ckr low-e 0.650 0.650 w w 18.20 18.20 33.77 33.77 0 0 0 0 a 0 0 0 0 0 0 0 C 0 0 0 C 16M-Omd 0.408 1.59 1.37 62 62 99 85 112 112 177 153 F 22A-tph 1.358 38.02 0,00 336 36 1372 0 0 0 0 0 61 c) AED excursion 35 70 Envelope loss/gain 2458 874 811 745 12 a) Infiltration 437 117 268 72 b) Room ventilation 0 0 C 0 13 Internal gains: Occupants @ 23C 0 0 0 0 Appliances/other 1200 0 Subtotal (lines 6 to 13) 2895 2191 1079 817 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2895 2191 1079 817 15 Duct loads 33% 53% 969 1167 331/6 53% 361 435 Total roam load 3864 335a 1440 1252 Air required (cfm) 75 149 65 56 Calculations approved by AC CA to meet all reauirements of Manual J 8ttt Ed. -I- " 202 1 -Mar-1 6 09:29: 0 1 1GCP a _." .,_,.., Right -Suite® Universal 2021 2L0.02 RSU08101 Page 5 E 1DocumnetslWrightsoit HVACIDUHAMEL RESIDENCE.rup Calc = MJ8 Front Door faces: S - wrightsoft` Right-J@ Worksheet Jab: Entire House Date: Mar 16, 2021 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY RM BATH 2 2 Exposed wall 6.0 ft 5.0 ft 3 Room height 6.0 ft heat/cool 8.0 ft heaticool 4 Room dimensions 1.0 x 40.3 ft 1.0 x 45.0 ft 5 Room area 40.3 ft2 45.0 W Ty Construction U-value Or HTM Area (ft-) Load Area W) Load number (Btuhlft� °F) (Btuhlfi1) or perimeter (ft) (Btuh) or perimeter (ft) (8tuh) Heat Cool Gross NIPIS Heat Go04 Gross NlPIS Heat I Cool 6 v 13A 5fcs 0:105 n 2.94 1.61 48 48 141 77 40 34 100 55 2 glazing, cir low-e 0.650 n 16.20 14.99 0 0 0 0 6 0 109 90 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 11 2 glazing, ctr tow-e 0.650 n 18,20 10.68 0 0 0 0 0 0 0 0 13A-5fcs 0.105 se 2.94 1.61 0 0 0 0 0 0 0 0 2 glazing, clr lows 0.650 se 18.20 25.63 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 se 18.20 25.63 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 se 18.20 25.86 0 0 0 0 0 0 0 0 2 glazing, cir iow-e 0.650 se 18.20 16.62 0 0 0 0 0 0 0 0 2 glazin4, cir low-e 0.650 se 18.20 16.62 0 0 0 0 0 0 0 0 13A-5fcs 0.105 s 2.94 1.61 0 0 D 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 D 0 0 0 0 2 gtazing, cir low-e 0.650 s 18.20 14.99 0 0 D 0 0 0 0 0 2 glazing, c1r low-e 0,650 s 18.20 14.99 0 0 0 0 0 0 0 0 W 13A-5fcs 0.105 sw 2.94 1.61 0 0 0 0 0 0 0 0 13A-5fcs 0.105 w 2.94 1.61 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.2.0 33.77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 D 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 13.20 33.77 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 83.77 0 0 0 0 0 0 0 0 C 16X19-Omd 0.408 1.59 1.37 40 40 64 55 45 45 71 62 F 22A tph 1.35E 38.02 0.00 0 0 a 0 0 0 0 0 6 c)AFD excursion -31 -9 Envelope losslgain 205 101 251 197 12 a) Infiltration 73 19 60 16 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 600 0 Subtotal (lines 6 to 13) 277 721 341 213 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 277 721 341 213 15 Duct loads 33% 53'. 93 384 33% 53% 114 114 Totai room load 370 1 1105 455 327 Air required (cfm) 17 491 211 15 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ f� vnrr9gl RlsoFt 2021-Mar-16 09:29:01 Right-SuiteO Universal 2021 21.0.02 RSU08101 Page 6 �� E:1DocumnetslW6ghtsoft HVACI6UHAMEL RESIDENCE.rup Calc = MJ8 Front Door faces: S + wrightsoft' Right-J@ Worksheet .lob: Entire House Date: Mar 16, 2021 QUICK CALCs, INC. By. 317 ST LUCIE LANE, FORT PIERCE. FL 34046 Phone: 772-466-6799 Fax: 772-466-6796 Email, QUICKCALCS@AOL.COM 1 Room name CHANGING RM M TOILET 2 Exposed wall 0 ft 0 ft 3 Room height 8.0 ft heaticcol 8.0 fi heat/cool 4 5 Room dimensions Room area 6.0 x 6.0 ft 36.0 ft, 4.0 x 5.0 ft 20.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft`) Load number (Btuh1ft2 °F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N1P15 Heat Cool Gross NIPIS Heat Cool 6 V 13A-5fcs 2 glazing, cir ow-e 2 glazing, cir low-e 0.105 0.650 0.650 n n n 2.94 18.20 18.20 1.61 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 11 2 glazing, clr low-, 0.650 In 18.20 10.68 0 0 0 0 0 0 0 0 13A-5fcs 0.105 se 2.94 1.61 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, cir low-, 0.650 0.650 se se, 18.20 18.20 25.63 25.63 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 se 18.20 25.86 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 se 18.20 16.62 0 0 0 0 0 0 0 0 2 cllazir q. cir low- 0.650 se 18.20 16.62 0 0 0 0 0 0 0 0 1� 13 0,650 s 1.61 0 0 0 0 0 0 0 0 az[ng 2 glazing, c!r !ow-e 0.650 s 18.20 8,20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 vv 13A-5fcs 0.105 sw 2.94 1.61 0 0 0 0 0 0 0 0 13A-5fcs 0.105 w 2.94 1.61 0 0 0 Q 0 0 0 0 2 glazing, clr low- 0.650 w 18-20 33,77 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 Q 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 0.650 0.650 w w 18.20 18.20 33.77 33.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16X19-Omd 0.408 1.59 1.37 36 36 57 49 20 20 32 27 F 22A-tph 1.358 38.02 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -2 -1 Envelope loss/gain 57 47 32 26 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 57 47 32 26 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 17 14 14 Subtotal 57 47 49 41 15 Duct loads 33% 53% 19 25 33% 53% 16 22 Total room load 76 72 66 62 Air required (cfm) 3 3 3 3 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed .,.w -► wr➢g:-.tsaft 2021-Mar-16 09:29'01 Right-Sulte,& Universal 2021 21.0.02 RSU08101 Page 7 E:1DacurnnetslWrightsott HVAC\DUHAMEL RESIDENCE.rup Calc = l Front Door faces: S wrighfsoft- Right-J® Worksheet Job: Entire House Date: Mar 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name M BATH M CLST 2 Exposed wall 10.2 rt 0 ft 3 Room height 8.0 ft heaticool 8.o ft heat/cool 4 Room dimensions 1.0 x 120.0 ft 4.0 x 4.0 ft 5 Roam area 120.0 ft' 16.0 ft2 Ty Construction U-value Or HTM Area (ft') Load Area (1`11) Load number (Btuhlft"F) (Btuhlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Coal Gross I N/PIS Heat Cook 6 13A-5fcs 0.105 n 2.94 1.61 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0_fi50 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 11 2 glazing, clr low-o 0.650 n 18.20 10.68 0 0 0 0 0 0 0 0 13A-5fcs 0.105 se 2.94 1.61 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 0.650 0.650 se se 18.20 18.20 25.63 25.63 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr Iew-e 0.650 se 1&2D 25.86 0 0 0 0 0 0 0 0 2 glazing, clrlow-e 0.650 se 18.20 16.62 0 0 0 0 0 0 0 0 2 cilazina, clr low-e 0.650 se 18.20 16.62 0 0 0 0 0 0 0 0 13A-5fcs 0.105 s 2.94 1.61 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 D 0 0 -G 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 W 13A-5fcs 0.105 sw 2.94 1.61 0 0 0 0 0 0 0 0 13A-5fcs 0.105 w 2.94 1.61 82 70 205 112 0 0 0 0 2 glazing, clr low-e 0.650 w 1&20 33.77 D D 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 1820 33.77 0 0 0 0 0 0 0 0 2 glazing, Or low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0,650 w 1&20 33.77 12 0 218 405 0 0 0 0 2 glazing, clr low-e 0.650 w 16.20 33-77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 C 16X19-0m6 0.408 1.59 1.37 120 120 190 164 16 16 25 22 F 22Atph -IMB 38.02 0-00 0 0 0 0 0 0 0 0 6 c) AED excursion 135 -1 Envelope loss/gain 613 816 25 21 12 a) Infiltration 123 33 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 ApplOncesfother 0 0 Subtotal (lines 6 to 13) 737 B49 25 21 Less e)demal load 0 D 0 0 Less transfer 0 0 0 0 Redistribution 31 26 25 -21 14 Subtotal 768 875 0 0. 15 Duct loads 33% 53% 257 466 33% 53% 0 0 Total room load Air required (cfm) 1025 46 1341 60 0 0 0 0' Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wF+- ♦nrrAgt�Fso 2021-Mar-16 09:29:01 Right -Suite® Universal 2021 21,0,02 RSU08101 Page 8 E:1Documnets\Wrightsofl HVACIDUHAMEL RESIDENCE.rup Calc = MJ8 Front Door faces, S wrightsoft° Right-J® Worksheet Job: Entire House Date: Mar 16, 2021 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-679B Emall: QUICKCALC,9@AOL.CQM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area HALL 0 ft 8.0 ft heat/cool 1.0 x 130.E ft 130.6 ft2 STAIRS UP 5.8 ft 8.0 ft heaticoot 1.0 x 56.5 ft 56,5 ftz Ty Construction number U-value (Btuhlft 7) Or HTM (Btuhlft2) Area or perimeter (ft) (BBttauhh) or�pen .meter (ft) (Btuh ) Heat Cool Gross NlP1S Heat Cool Gross NIPIS Heat Cool 6 11 13A-5fcs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, cir low-e 13A-5fcs 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 plazina, cir iow-e l 5fcs 2 g 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, cir low-e 13A-5fcs 13A 5fcs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 16X19-0md 22A-tph 0.105 0.650 0.650 0.650 0.650 0.105 0.650 0.650 0.650 0.650 0.650 0.650 0.650 0,650 0.650 0.105 0.105 0,650 0,650 0.650 0.650 0.650 0.650 0.408 1.358 n n n n n se se se se se se s s S s SW w w w w w w w 2.94 18.20 18.20 18.20 18.20 2.94 18.20 18.20 18.20 18.20 18.20 2.94 18.20 18.20 18.20 2.94 2.94 18.20 18.20 18,20 18.20 18.20 1820 1.59 38.02 1.61 14.99 14.99 14.99 10.68 1.61 25.63 25.63 25.86 16.62 16,62 1.61 14.99 14.99 14.99 1.61 1.61 33.77 33.77 33.77 33.77 33.77 33.77 1.37 0.00 0 0 0 0 a 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 131 0 0 0 0 0 a 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 131 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 207 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 179 0 0 0 0 0 0 47 0 0 24 0 0 0 0 0 0 0 0 0 0 0 0 D 0 57 0 0 0 0 0 0 23 0 0 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 57 0 0 0 0 0 0 68 0 0 428 0 0 0 0 0 0 0 0 0 0 0 0 0 0 90 0 0 0 0 0 0 37 0 0 608 0 0 0 0 0 0 0 0 0 0 0 0 0 0 77 0 4 W G F 6 c)AED excursion -7 108 Envelope losslgain 207 171 685 830 12 a) Infittration 0 0 71 19 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 D 0 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 207 171 656 849 Less external load 0 0 0 6 14 Less transfer Redistribution Subtotal 0 -207 0 0 -171 0 0 49 705 0 40 889 15 Duct loads 531/0 0 0 33% 53% 236 474 Total room load 0 D 941 1363 Air required (cfm) 0 0 43 61 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ �-►- wr[g11-its """"`-"--"'- VACIRight Suite® Universal 2021 21.0.02 RStJu81fl1 2021-Mar-16 09:29:01 Page 9 �A E:00cumnetslWrightsoft HDUHAMEL RESIDENCE.rup Calc - MJB Front Door faces: S wrightsoft, Right-J® Worksheet Job: Entire House Date: Mar 16, 2021 By: QUICK CALCS, INC, 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone- 772-466-6799 Fax: 772-466-6796 Email. 4UICKCALCS@AOL.COM 1 Room name AHU CLST BATH 3 2 Exposed wall 0 ft 12.5 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 13.3 ft 1.0 x 60.5 ft 5 Room area 13.3 ft2 60.5 ft' Ty Construction U-value Or HTM Area (w) Load Area (ft') Load number (Btuhlft''F) (Btuhlftz) or perimeter (ft) (Btuh) or perimeter (ft) (Stuh) Heat Cool Gross NIPIS Heat Cool Gross NIPIS Heat Cool 6 13A-5fcs 0.105 n 2.94 1.61 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 rr 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 11 2 glazing, clr low-e 0,650 n 18.20 10.68 0 0 0 0 0 0 0 0 13A-5fcs 0,105 se 2.94 1.61 0 0 0 0 100 100 295 161 2 glazing, cir low-e 0,650 se 18.20 25.63 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 se 18.20 25.63 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 se 18.20 25.86 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0,650 se 18.20 16.62 0 0 0 0 0 0 0 0 2 giazinq, or low-e 0.650 se 18.20 16.62 0 0 0 0 0 0 0 0 W, 0,650 s 2.20 1.61 0 0 0 0 0 0 0 ��_c 2 glazing, cir low-e 2 glazing 0.650 s 18.20 14.99 0 0 0 0 0 0 D 0 0 2 glazing, clr low-e 0,650 s 18.20 14.99 0 0 0 0 0 0 0 0 ���CCG 2 glazing, cir low-o 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 W 13A-5fcs 0.105 sw 2.94 1.61 0 0 0 0 0 0 0 0 13A-5fcs 0.105 w 2.94 1.61 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0,650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.65D w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18,20 33.77 0 0 0 0 0 0 0 0 C 16X19-0md 0,408 1.59 1.37 13 13 21 18 60 60 96 83 F 22A tph 1.358 38.02 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -1 -12 Lrtvelope loss/gain 21 17 391 232 12 a) Infiltration 0 0 152 41 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 21 17 542 273 Less external load 0 0 0 0 Less transfer 0 0 D 0 Redistribution -21 -17 28 23 14 Subtotal 0 0 570 296 15 Duct loads 33% 53% 0 0 33% 53% 191 158 Total room load 0 0 761 454 Air required (cfm) 0 0 34 20 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed - v.rragFwsoit^ 2021-Mar-16 09:29:01 Right -Suite® Universal 2021 21.0.02 RSU08101 Page 10 �� CADocumnets\WrightsoR HVACIDUHAMEL RESIDENCE_rup Calc = MJ8 Front Door faces' S + wrightsoft' Right-JO Worksheet Job: Entire House Date: Mar 16, 2021 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax, 772-466.6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 CLST 2 2 Exflosed wall 11.0 ft 2.0 ft 3 Room height 8.0 ft heatfcool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 163.0 ft 163.0 ft' 2.0 x 9.0 ft 18.0 ft2 Ty Construction U-value Or HTM Area (ft-) Load Area (ft.) Load number (Btuhlftl-°F) (Btuh/W) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat C001 Gross N/P/S Heat Cool Gross N/P/S Heat G06 6 13A-5fcs 0.105 n 2.94 1.61 88 73 215 117 16 16 47 26 2 glazing, clr low-e 0.65C n 18.2C 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.99 15 0 273 225 0 0 0 0 2 glazing, cir low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 11 2 glazing, clr low-e 0.650 n 18.20 10.68 0 0 0 0 0 0 0 0 13A-51cs 0.105 se 2.94 1.61 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 se 18.2C 25.63 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0,650 se 18.20 25.63 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 se 18.20 25.86 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 se 18.20 16.62 0 0 0 0 0 0 0 0 2 aiazinq, cir low-e 0.650 se 18.20 16.62 0 0 0 0 0 0 0 0 13A 5fcs 0.105 s 2.94 1.61 0 0 0 0 0 0 0 0 2 glazing, cir iow-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 D 4 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 W 13A-5fcs 0.105 sw 2.94 1.61 0 0 0 0 0 0 0 0 13A 5fcs 0.105 w 2.94 1.61 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 33.77 0 C 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.65D w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr low-o 0-650 w 18.20 33,77 0 0 0 0 0 0 0 0 2 glazing, cir iow-e C.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 163 163 258 223 18 18 29 25 F 22A-tph 1.358 38.02 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -57 2 Envelope loss/gain 746 508 76 48 12 a) Infiltration 133 36 24 6 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 800 0 Subtotal (lines 6 to 13) 879 1344 100 54 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 101 71 -100 -54 14 Subtotal 980 1415 0 0 15 Duct loads 33% 53% 328 753 33% 53% 0 0 Total room load 1308 2168 0 0 Air required (cfm) 59 961 01 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - w, ,,,,F,,,.,`... ft^' 2021-Mar-16 09,29,01 _ r�g1-�tso "" "' Right-SuiteO Universal 2021 21.0.02 RSU08101 Page 11 E1Documnets\Wrightsoii HVAC DUHAIv1EL RESIUENCE,rup Calc = M-18 Front hoot faces: S + wrightsoft, Right-J® Worksheet Job: Entire House Date: Mar 16, 2021 QUICK CALCS, INC. By 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone_ 772-466-6799 Fax: 772-466-6796 Email: RUICKCALCS@AOL.COM 1 Roam name BEDROOM 3 WIC 3 2 Exposed wall 18.9 ft 12.7 ft 3 Room height 8.0 ft heaticool &0 ft heaticeol 4 5 Room dimensions Room area 1.0 x 167.5 ft 167.5 ft225.0 1.0 x 25.0 ft ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/W °F) (Btu ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIPIS Heat Cool Gross NlP1S Heat Cool 6 13A-5fcs 0.105 n 2.94 1.61 80 65 191 104 48 48 141 77 2 glazing, clr Icw-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 15 0 273 225 0 0 0 0 2 glazing, cir low-e 0.650 n 18,20 14.99 0 0 0 0 0 0 0 0 11 2 glazing, clr low-e 0.650 n 18.20 10.68 0 0 0 0 0 0 0 0 13A 5fcs 0.105 se 2.94 1.61 72 57 166 91 54 54 158 86 2 glazing, clr low-e 0.650 se 18.20 25.63 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 se 18.20 25.63 15 2 273 384 0 0 0 0 2 glazing, cir low-e 0.650 se 18-20 25.86 D 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 se 18.20 16.62 0 0 0 0 0 0 0 0 2 q VACI, cir low-e 0.650 se 18.20 16.62 0 0 0 0 0 0 0 0 1� 0.105 s 1.61 0 0 0 0 0 0 0 0 2 glazing, clr lower; 2 glazing, 0.650 s 18.20 8.20 14.99 0 0 D 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 W 13A-5fcs 0.105 sw 2.94 1.61 0 0 0 0 0 0 0 0 13A-5fcs 0.105 w 2.94 1.61 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, oir 11 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 1.59 1.37 168 168 266 229 25 25 40 34 F 22A-tph 1.358 38.02 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -59 -14 Envelope loss/gain 1169 975 339 184 12 a) 4nfiltration 229 61 154 41 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Applianceslother 350 100 Subtotal (lines 6 to 13) 1398 1386 492 325 Less external load 0 0 0 0 Less transfer a 0 0 0 Redistribution 81 51 0 a 14 Subtotal 1479 1437 492 325 15 Duct loads 33% 53% 495 765 33% 53% 165 173 Total room load 1974 2203 657 498 Air required (cfm) 89 981 130 22' Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -- -41- wr9grrtsafi°- 2021-Mar-16 09:29:01 Rlght-Suite@ Universal 2021 21.0.02 RSUG8101 Page 12 E:1Qocumnets\Wrightsoft HVACIDUHAMEL RESIDENCE_rup Cafe = MJ6 Front Door faces: S wr;g tsoft Right-JO Worksheet Date: Entire House By: QUICK CALCS, INC. __... , ..,— ---- -- n�,,— 779-AFR_F7AQ v= 772-466-6796 Email- QUICKCALCS@AOL.COM alt Mar 16, 2021 �.F- wlr"i91-ststy7F�^ Right -Suite® Universal 2021 21.0.02 RSUO$lDi 'EGA E:\DocumnetslWrightSoftHVAC\DUHAMF-LRESIDENCE.rup Calc = MJ8 Front Door faces: 2021-Mar-16 09:29V Page 13 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: DUHAMEL RESIDENCE Builder Name: Street: LOT 64 NETTLES ISLAND Permit Office: ST LUCIE COUNTY City, State, Zip: JENSEN BEACH , FL, Permit Number: U Owner: Jurisdiction: ST LUCIE COUNTY w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in an dropped ceiling/soffit Y PP g /soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealer!. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed, material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be pennitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Showeritub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shalt be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 3/16/2021 10:10 AM EnergyGaugeJ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1