Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOF 1/24/22,4,47 PM Florida Building Code Online RECEIVED, �' 'A 2-6 2022ZIIJU BCIS Home Log In User Registration j.•Hot Topics I Submit Surcharge i Stats&Facts i Publications i Contact Us BCIS Site Map Links i Search FlOrlda St.Lucie County t➢. Permitting ,. i;<;E ®�`�Product Approval l�k r fir. USER:Public User rs•X:rSf ti E:rn�: 1 Ph.__.U'�r�•ti�lzn Product Approval Menu>Product or Application Search>Qpplicatlon List>Application Detail FL# FL27499-R4 Application Type Revision Code Version 2020 Application Status Approved Comments Archived OftyvLl Product Manufacturer Dynamic Metals Address/Phone/Email 3201 SE Dominica Terace Stuart,FL 34997 (772)872-8030 juan@dynamicmetal.net 5� Gt-i'ry,P Authorized Signature Lara Jesus juan@dynamicmetal.net rr Q, Ct Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Scott Wolters Evaluation Report Florida License PE-62354 Quality Assurance Entity Keystone Certifications,Inc. ®�� Quality Assurance Contract Expiration Date 12/06/2026 Validated By Lucas A.Turner,RE.,MBA ❑ Validation Checklist-HardcopR�ceived Certificate of Independence' FL27499 R4 COI Dyn COI.pdf Referenced Standard and Year(of Standard) Standard Year TAS 100 1995 TAS 110 2000 TAS 125 2003 Equivalence of Product Standards Certified By Sections from the Code https:/Ifloridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe°/p2bOsCepABg3p/o2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d 1/5 1/24/22,4c47 PM Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 04/18/2021 Date Validated 04/30/2021 Date Pending FBC Approval 05/03/2021 Date Approved 06/08/2021 Summary of Products Go to Page Page 1/2 FL# Model,Number or Name Description 27499.1 DM Class 1000 1"Nailstrip 26 Ga.galvalume coated steel roof panel, 16"wide,with 1" snap fit seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 4991 Dwg_pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 4991 Eval.pdf Created by Independent Third Party:Yes 27499.2 DM Class 1000 1"Nailstrip, .032"Aluminum roof panel, 16"wide,with 1"snap fit seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 4992 Dwg,pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: Please see Eva[report for Limits of Use. FL27499 R4 AE 4992 Eval.pdf Created by.Independent Third Party:Yes 27499.3 DM Class 1050 1 1/2"Nailstrip .032"Aluminum Roof Panel, 19"Wide,with 1 1/2"snap fit seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 4993 Dw pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters,P.E. FLPE#62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 4993 Eval.od Created by Independent Third Party:Yes 27499.4 DM Class 1050 1 1/2"Nailstrip 24 Ga.Galvalume coated steel roof panel, 19"wide,with 1 1/2"snap fit seams Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 4994 Dwg,pdf Approved for use outside HVHZ:Yes Verified By:.Scott Wolters,P.E. FLPE#62354 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation'Reports Other: Please see Eva[report for Limits of Use. FL27499 R4 AE 4994 Eval.pdf Created by Independent Third Party:Yes - 27499.5 DM Class 1150 1"Mechanical Seam .032"Aluminum roof panel,21"wide,with 1"standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 4995 Dwg,pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters FLPE#62394 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other: Please see Eva[Report for Limits of Use. FL27499 R4 AE 4995 Eval.pdf Created by Independent Third Party:Yes 27499.6 DM Class 1150 1"Mechanical Seam .032"Aluminum roof panel,21"wide,with 1"standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: No FL27499 R4 II 4996 Dwg,pd Approved for use outside HVHZ:Yes Verified By: Scott Wolters FLPE# 62394 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Installation Drawings and Eval Report for FL27499 R4 AE 4996 Eval.odf Limits of Use. Created by Independent Third Party:Yes 27499.7 DM Class 1150 1"Mechanical Seam 26 Ga.Galvalume coated steel roof panel,21"wide,with 1" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 4997 Dwg.pd Approved for use outside HVHZ:Yes Verified By: Scott Wolters FLPE#62394 https://floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3°/a2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d 2/5 1/24/22,4'47 PM Florida Building Code Online Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawings and Eva]Report for FL27499 R4 AE 4997 Eval.pdf Limits of Use. Created by Independent Third Party:Yes 27499.8 DM Class 1500 1 1/2"Mechanical .032"Aluminum roof panel,20"wide,with 1 1/2"standing Seam seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 4998 Dwg,pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Eva[report for Limits of Use. FL27499 R4 AE 4998 Eval.pdf Created by Independent Third Party:Yes 27499.9 DM Class 1500 1 1/2"Mechanical 16 oz.Copper roof panel, 16"wide,with 1 1/2"standing Seam seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 4999 Dwag.pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: Please see Eva[report for Limits of Use. FL27499 R4 AE 4999 Eval.pdf Created by Independent Third Party:Yes 27499.10 DM Class 1500 1 1/2"Mechanical 26 Ga.ga]valume coated steel roof panel, 16"wide,with 1 1/2" Seam standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49910 Dwa.pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 49910 Eval.pd Created by Independent Third Party:Yes 27499.11 DM Class 1500 1 1/2"Mechanical .032"Aluminum roof panel,16"wide,with 1 1/2"standing Seam seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49911 Dwg,pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 49911 Eval.pdf Created by Independent Third Party:Yes 27499.12 DM Class 1500 1 1/2"Mechanical 24 Ga.ga]valume coated steel roof panel, 16"wide,with 1 1/2" Seam standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49912 Dwg,pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49912 Eval.pdf Created by Independent Third Party:Yes 27499.13 DM Class 1500 1 1/2"Mechanical 24 Ga.ga[va[ume coated steel roof panel,20"wide,with 1 1/2" Seam, standing seams. Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL27499 R4 II 49913 Dwg,pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 49913 Eval.pdf Created by Independent Third Party:Yes 27499.14 DM Class 1750 1 3/4"Snaplock 24 Ga.Galvalume coated steel roof panel, 18"wide,with 1 3/4"Snaplock seams,attached to metal deck. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49914 Dwgpdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters, P.E. FLPE#62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Eva[report for Limits of Use. FL27499 R4 AE 49914 Eval.pdf Created by Independent Third Party:Yes 27499.15 DM Class 1750 1 3/4"Snaplock 032"Aluminum roof panel, 18"wide,with 1 3/4"Snaplock seams,attached to metal deck. https://fioddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6Ffy6ER6EzwMOZCvLCMMgag%3d%3d 3/5 1/24/22,4-:47 PM Florida Building Code Online Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49915 Dwo,pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 49915 Eval.pdf Created by Independent Third Party:Yes 27499.16 DM Class 1750 1 3/4"Snaplock .032"aluminum roof panel, 18"wide,with 1 3/4"Snaplock seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49916 Dwg,pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 49916 Eval.pdf Created by Independent Third Party:Yes 27499.17 DM Class 1750 1 3/4"Snaplock 24 Ga.galvalume coated steel roof panel, 18"wide,with 1 3/4" Snaplock seams. Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL27499 R4 II 49917 dwg pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 49917 Eval.pdf Created by Independent Third Party:Yes 27499.18 DM Class 2000 2"Mechanical Seam .032 Aluminum roof panel, 18"wide,with 2"standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49918 Dwg.pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 49918 Eval.Ddf Created by Independent Third Party:Yes 27499.19 DM Class 2000 2"Mechanical Seam 24 Ga.galvalume coated steel roof panel, 18"wide,with 2" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49919 Dwg,pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Eva[report for Limits of Use. FL27499 R4 AE 49919 Eval,pdf Created by Independent Third Party:Yes 27499.20 DM Class 500 5V Crimp 26 Ga.galvalume coated steel roof panel,24"wide,with 5V crimp. Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL27499 R4 II 49920 Dwo,pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Eva[report for Limits of Use. FL27499 R4 AE 49920 Eval.pd Created by Independent Third Party:Yes Go to Page Page 1/2 fly Back Plext Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Ibojej _ EC�ec]M hfps://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6Ffy6ER6E2wMOZCvLCMMgag%3d%3d 4/5 WOLTERS ENGINEERING ENGINEERING,DRAFTING,CONSULTING 15211 971h Road N West Palm Beach,FL 33412 Ph/Fx:(561)225-1982 PRODUCT EVALUATION (FOR HVHZ APPROVED PRODUCT) PRODUCT: DM CLASS 500 26 GA. GALVALUME 5V CRIMP 24 WIDE ROOF PANEL(FLPA#27499.20) MANUFACTURER: DYNAMIC METALS, LLC 3201 SE DOMINICA TERRACE STUART, FL 34997 To all concerned, The DM Class 500 Series 26 Ga. Galvalume 5V Crimp 24"Wide Roof Panel, manufactured by Dynamic Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the requirements of Sections 1507.4.and 1518-.9 of the 7th Edition (2020) Florida Building Code. The panel has been tested per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443.38-45044 and H2686.02- 450-44, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004- 02-01 and VLS-005-02-01. Technical Documentation: 1. Drawing "5VS-HZ"dated 8/15/1.9, signed and sealed by Scott Wolters, PE. 2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE. 3. Test Reports listed above by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE. 4. Supplemental Calculations to support 5VS-HZ, signed and sealed by Scott Wolters, PE. I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 7th Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions. Limitations: This panel is approved for use inside and outside of the HVHZ. Overall Limitations: Maximum Panel Width: 24"(nominal) Fastener Spacing across panel: 12"(at Overlaps &Center Rib) Min. Slope: HVHZ: 2'712" Non-HVHZ: Y2'712" (with Lap Sealant) 3712" (no Lap Sealant) 5Pf;CI&IZING IN IMPACT I,�515MW CWTAINWA15, 5TOFZ FFVNf5, & WINI70W5 Option#1 Option#2 Installation Installation Max. Design Pressure: -117.75 psf -206 psf Fastener Spacing: 4" From Ends, 16" Max. O.C. 4" From Ends, 8" Max. O.C. Min Panel Fasteners: #10x1 %" HiLo HWH Screw #10xl '/z" HiLo HWH Screw with Weather-seal Washer with Weather-seal Washer Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note#2 below) Note: Outside of the HVHZ, in areas with windspeeds < 170 mph, 1" round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Underlayment: Minimum ASTM D 226 Type II, installed and anchored per FBC Section 1507.1.1.1 (min). (or) Any underlayment with a valid FLPA or Miami-Dade NOA Note: Outside of the HVHZ, in areas with windspeeds< 170 mph, 1" round plastic caps meeting the requirements of FBC Section 1507.1.1.1 may be used to prevent galvanic reactions. Minimum Substrate: '/Z' (15/32" min)4-ply CDX Plywood or 3/4"solid wood planks (S.G. _ .42 min) nailed to 2x rafters spaced 24" max. on center with 8d ring-shank nails spaced 6"on center. Note: The 1/4"wood planking must be installed as a solid deck and must be nailed or fastened in a manner equal to the deck above, or as specified by a Florida licensed Architect/Engineer Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. 5PrCIALIZING IN IMPACT P,�515TANT CUPfAINWALI,5, 51"OP._FV0Nf5, & WINPOW5 4. All panel system perimeters, penetrations, and transitions to be flashed and sealed per the requirements of RAS 133. 5. Rational analysis, provided by a Florida licensed Architect/Engineer per FAS 61 G20.3.005(e), may be used for project specific approval by the local authorities having jurisdiction. '6. Where required by the Florida Building Code, panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement, "Dynamic Metals FL#27499.20, DM Class 500". Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per approval of 3rd party QA provider, to the dimensions shown on Drawing 5VS-HZ: SSQ-6800617 SSQ-5150216 SSQ-6810617 SSQ-6690517 SSQ-4560615 SSQ2-2310920 5VC-0490718 5VC-0360516 SSQ2-2320920 Re-Roofinq: The DM Class 500 Series 26 Ga. Galvalume 5V Crimp 24"Wide Roof Panel may be installed over a single layer of existing asphalt shingles, provide the existing roof meets the requirements of Section 1511 of the Florida Building Code. If you have any questions or need more information concerning this approval, please contact me. Thank you, �,<°• No 62354 Scott Wolters FL PE#62354 �o STATE OF APR 15 2021 5P�CKIZIN6 IN IMPACT p1�515TANT CUpTAINVVALI,5, 5T0FFPp0NT5, & WIN170W5 m N A' 1 •9 61 x twQQ�� C (� m'. ® is o w cn,^ r•j :� m. r- v ^ m O N t N� O 7, Cl - scoTT ra�s 1 DYNAMIC METALS FL PEP62354 - �: _ - - LTERS'ENGNESIND'K9 „' C � y'✓�� 3201 SE DQMINICA TERRACE wir,�.dynomicmerGlnet n * - r _ - 1 ®� 152t1 4SCA RDAD N:•- { }�t J` NA4SE CHANGE 9/15/14 STUART,FL 34997 FAX:�772)2c7.2465 riEST PAW REACN..�33Al2 CJ�. �gPry I�j 7Uj) .;Q• iST SUBMITTAL _�18 15 , (561)225-1082 !:R (�,� t` =� NPH:(7721 24 1-2'165 EMAIL:injc+��oyrlomicmetal,net ,• „••• t_:.•'�.�•�.'� DRiNTS ISSGED EGRIRFV.tl( DATE