Loading...
HomeMy WebLinkAbout9936426tnxTower Report - version 8.1.1.0 Date: August 13, 2021 Crown Castle 2000 Corporate Drive Canonsburg, PA 15317 (724) 416-2000 Subject: Structural Analysis Report Carrier Designation: DISH Network Co-Locate Site Number: MIMIA00169A Site Name: FL-CCI-T-813722 Crown Castle Designation: BU Number: 813722 Site Name: W INDRIO BRA351 JDE Job Number: 643565 Work Order Number: 1964296 Order Number: 551657 Rev. 1 Engineering Firm Designation: Crown Castle Project Number: 1964296 Site Data: 12888 Indrio Rd., Ft. Pierce, St. Lucie County, FL Latitude 27° 31' 33.7'', Longitude -80° 27' 19.7'' 120.5 Foot - Monopole Tower Crown Castle is pleased to submit this “Structural Analysis Report” to determine the structural integrity of the above-mentioned tower. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC5: Proposed Equipment Configuration Sufficient Capacity This analysis utilizes an ultimate 3-second gust wind speed of 155 mph as required bythe 2020 Florida Building Code, 7th Edition. Applicable Standard references and design criteria are listed in Section 2 - ''Analysis Criteria''. Structural analysis prepared by: Roy Zhou Respectfully submitted by: Eric S. Stover, P.E. Engineering Supervisor August 13, 2021 120.5 Ft Monopole Tower Structural Analysis CCI BU No 813722 Project Number 1964296, Order 551657, Revision 1 Page 2 tnxTower Report - version 8.1.1.0 TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Equipment Configuration Table 2 - Other Considered Equipment 3) ANALYSIS PROCEDURE Table 3 - Documents Provided 3.1) Analysis Method 3.2) Assumptions 4) ANALYSIS RESULTS Table 4 - Section Capacity (Summary) Table 5 – Tower Component Stresses vs. Capacity – LC5 4.1) Recommendations 5) APPENDIX A tnxTower Output 6) APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations August 13, 2021 120.5 Ft Monopole Tower Structural Analysis CCI BU No 813722 Project Number 1964296, Order 551657, Revision 1 Page 3 tnxTower Report - version 8.1.1.0 1) INTRODUCTION This tower is a 120.5 ft Monopole tower designed by FWT INC.. 2) ANALYSIS CRITERIA TIA-222 Revision: TIA-222-H Risk Category: II Wind Speed: 155 mph Exposure Category: C Topographic Factor: 1 Service Wind Speed: 60 mph Table 1 - Proposed Equipment Configuration Mounting Level (ft) Center Line Elevation (ft) Number of Antennas Antenna Manufacturer Antenna Model Number of Feed Lines Feed Line Size (in) 114.0 114.0 3 fujitsu TA08025-B604 1 1-1/2 3 fujitsu TA08025-B605 3 jma wireless MX08FRO665-21 w/ Mount Pipe 1 raycap RDIDC-9181-PF-48 1 tower mounts Commscope MC-PK8-DSH Table 2 - Other Considered Equipment Mounting Level (ft) Center Line Elevation (ft) Number of Antennas Antenna Manufacturer Antenna Model Number of Feed Lines Feed Line Size (in) 121.0 124.0 3 ericsson TME-RRUS-11 12 3 1 2 1-5/8 5/16 3/8 3/4 123.0 3 ericsson TME-RRUS-11 6 kathrein 800 10122 w/ Mount Pipe 3 kathrein 800 10764 w/ Mount Pipe 12 kathrein 860 10025 1 raycap DC6-48-60-18-8F 4 rfs celwave ATM192012B-0 2 rfs celwave ATM19801712-0 6 rfs celwave FDGW5504/3C-3L 121.0 1 tower mounts Miscellaneous [NA 502-1] 1 tower mounts Side Arm Mount [SO 101-3] 96.0 98.0 9 decibel DB848H90E-XY w/ Mount Pipe 9 1-5/8 96.0 1 tower mounts Platform Mount [LP 303-1] 3) ANALYSIS PROCEDURE Table 3 - Documents Provided Document Reference Source 4-TOWER FOUNDATION DRAWINGS/DESIGN/SPECS 1173534 CCISITES 4-TOWER MANUFACTURER DRAWINGS 216137 CCISITES August 13, 2021 120.5 Ft Monopole Tower Structural Analysis CCI BU No 813722 Project Number 1964296, Order 551657, Revision 1 Page 4 tnxTower Report - version 8.1.1.0 3.1) Analysis Method tnxTower (version 8.1.1.0), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. When applicable, Crown Castle has calculated and provided the effective area for panel antennas using approved methods following the intent of the TIA-222 standard. 3.2) Assumptions 1) Tower and structures were maintained in accordance with the TIA-222 Standard. 2) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. This analysis may be affected if any assumptions are not valid or have been made in error. Crown Castle should be notified to determine the effect on the structural integrity of the tower. 4) ANALYSIS RESULTS Table 4 - Section Capacity (Summary) Section No. Elevation (ft) Component Type Size Critical Element P (K) SF*P_allow (K) % Capacity Pass / Fail L1 120.5 - 90.1693 Pole TP37.405x24x0.25 1 -10.09 1706.85 25.2 Pass L2 90.1693 - 45.6719 Pole TP56.569x34.7689x0.375 2 -20.79 3874.25 28.4 Pass L3 45.6719 - 0 Pole TP76x52.6162x0.4375 3 -43.40 6445.20 30.2 Pass Summary Pole (L3) 30.2 Pass Rating = 30.2 Pass Table 5 - Tower Component Stresses vs. Capacity – LC5 Notes Component Elevation (ft) % Capacity Pass / Fail 1 Anchor Rods 0 24.8 Pass 1 Base Plate 0 15.5 Pass 1, 2 Base Foundation (Compared w/ Design Loads) 0 37.9 Pass Structure Rating (max from all components) = 37.9% Notes: 1) See additional documentation in “Appendix C – Additional Calculations” for calculations supporting the % capacity consumed. 2) Foundation capacity determined by comparing analysis reactions to original design reactions. 4.1) Recommendations The tower and its foundation have sufficient capacity to carry the proposed load configuration. No modifications are required at this time. August 13, 2021 120.5 Ft Monopole Tower Structural Analysis CCI BU No 813722 Project Number 1964296, Order 551657, Revision 1 Page 5 tnxTower Report - version 8.1.1.0 APPENDIX A TNXTOWER OUTPUT The Pathway to Possible Crown Castle 2000 Corporate Drive Canonsburg, PA 15317 Phone: (724) 416-2000 FAX: Job: PSEC 9163 (for AT&T) Project: 813722 - W INDRIO BRA351 Client: CROWN CASTLE Drawn by: RZhou App'd: Code: TIA-222-H Date: 08/13/21 Scale: NTS Path: C:\Users\RZhou\Desktop\Work Area\813722\WO 1964296 - SA\Prod\813722_RPA.eri Dwg No. E-1 120.5 ft 90.2 ft 45.7 ft 0.0 ft REACTIONS - 155 mph WIND TORQUE 1 kip-ft 37 K SHEAR 3024 kip-ft MOMENT 43 K AXIAL ARE FACTORED ALL REACTIONS Section123 Length (ft)30'3-31/32"49'3-31/32"52'11-1/32" Number of Sides181818 Thickness (in)0.25000.37500.4375 Socket Length (ft)4'9-31/32"7'3" Top Dia (in)24.000034.768952.6162 Bot Dia (in)37.405056.569076.0000 GradeA572-65 Weight (K)2.59.016.027.5MATERIAL STRENGTH GRADE GRADEFy FyFu Fu A572-65 65 ksi 80 ksi TOWER DESIGN NOTES 1. Tower designed for Exposure C to the TIA-222-H Standard. 2. Tower designed for a 155 mph basic wind in accordance with the TIA-222-H Standard. 3. Deflections are based upon a 60 mph wind. 4. Tower Risk Category II. 5. Topographic Category 1 with Crest Height of 0' 6. TOWER RATING: 30.2% August 13, 2021 120.5 Ft Monopole Tower Structural Analysis CCI BU No 813722 Project Number 1964296, Order 551657, Revision 1 Page 6 tnxTower Report - version 8.1.1.0 Tower Input Data The tower is a monopole. This tower is designed using the TIA-222-H standard. The following design criteria apply: x Tower base elevation above sea level: 19'. x Basic wind speed of 155 mph. x Risk Category II. x Exposure Category C. x Simplified Topographic Factor Procedure for wind speed-up calculations is used. x Topographic Category: 1. x Crest Height: 0'. x Deflections calculated using a wind speed of 60 mph. x A non-linear (P-delta) analysis was used. x Pressures are calculated at each section. x Stress ratio used in pole design is 1. x Tower analysis based on target reliabilities in accordance with Annex S. x Load Modification Factors used: Kes(Fw) = 0.95. x Maximum demand-capacity ratio is: 1.05. x Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered. Options Consider Moments - Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules Consider Moments - Horizontals Assume Legs Pinned Calculate Redundant Bracing Forces Consider Moments - Diagonals ¥ Assume Rigid Index Plate Ignore Redundant Members in FEA Use Moment Magnification ¥ Use Clear Spans For Wind Area SR Leg Bolts Resist Compression ¥ Use Code Stress Ratios Use Clear Spans For KL/r All Leg Panels Have Same Allowable ¥ Use Code Safety Factors - Guys Retension Guys To Initial Tension Offset Girt At Foundation Escalate Ice ¥ Bypass Mast Stability Checks ¥ Consider Feed Line Torque Always Use Max Kz ¥ Use Azimuth Dish Coefficients Include Angle Block Shear Check Use Special Wind Profile ¥ Project Wind Area of Appurt. Use TIA-222-H Bracing Resist. Exemption Include Bolts In Member Capacity Autocalc Torque Arm Areas Use TIA-222-H Tension Splice Exemption Leg Bolts Are At Top Of Section Add IBC .6D+W Combination Poles Secondary Horizontal Braces Leg ¥ Sort Capacity Reports By Component ¥ Include Shear-Torsion Interaction Use Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets SR Members Are Concentric Ignore KL/ry For 60 Deg. Angle Legs ¥ Pole Without Linear Attachments Pole With Shroud Or No Appurtenances Outside and Inside Corner Radii Are Known Tapered Pole Section Geometry Section Elevation ft Section Length ft Splice Length ft Number of Sides Top Diameter in Bottom Diameter in Wall Thickness in Bend Radius in Pole Grade L1 120'6''-90'2- 1/32'' 30'3-31/32'' 4'9-31/32'' 18 24.0000 37.4050 0.2500 1.0000 A572-65 (65 ksi) L2 90'2-1/32''- 45'8-1/32'' 49'3-31/32'' 7'3'' 18 34.7689 56.5690 0.3750 1.5000 A572-65 (65 ksi) L3 45'8-1/32''-0' 52'11-1/32'' 18 52.6162 76.0000 0.4375 1.7500 A572-65 (65 ksi) August 13, 2021 120.5 Ft Monopole Tower Structural Analysis CCI BU No 813722 Project Number 1964296, Order 551657, Revision 1 Page 7 tnxTower Report - version 8.1.1.0 Tapered Pole Properties Section Tip Dia. in Area in2 I in4 r in C in I/C in3 J in4 It/Q in2 w in w/t L1 24.3317 18.8456 1342.9976 8.4313 12.1920 110.1540 2687.7623 9.4246 3.7840 15.136 37.9435 29.4825 5142.0486 13.1900 19.0017 270.6094 10290.863 3 14.7440 6.1433 24.573 L2 37.4163 40.9373 6118.1231 12.2098 17.6626 346.3890 12244.296 6 20.4725 5.4593 14.558 57.3838 66.8849 26683.665 1 19.9489 28.7371 928.5457 53402.441 3 33.4488 9.2961 24.79 L3 56.6123 72.4567 24923.171 0 18.5235 26.7291 932.4375 49879.136 6 36.2352 8.4905 19.407 77.1049 104.9280 75690.501 8 26.8247 38.6080 1960.4875 151480.59 92 52.4740 12.6060 28.814 Tower Elevation ft Gusset Area (per face) ft2 Gusset Thickness in Gusset Grade Adjust. Factor Af Adjust. Factor Ar Weight Mult. Double Angle Stitch Bolt Spacing Diagonals in Double Angle Stitch Bolt Spacing Horizontals in Double Angle Stitch Bolt Spacing Redundants in L1 120'6''- 90'2-1/32'' 1 1 1 L2 90'2-1/32''- 45'8-1/32'' 1 1 1 L3 45'8-1/32''- 0' 1 1 1 Feed Line/Linear Appurtenances - Entered As Round Or Flat Description Face or Leg Allow Shield Exclude From Torque Calculation Componen t Type Placement ft Total Number Number Per Row Clear Spacing in Width or Diamete r in Perimete r in Weight plf *** Feed Line/Linear Appurtenances - Entered As Area Description Face or Leg Allow Shield Exclude From Torque Calculation Componen t Type Placement ft Total Number CAAA ft2/ft Weight plf LCF158-50A(1- 5/8) B No No Inside Pole 120'6'' - 5' 12 No Ice 0.00 0.80 12 PAIR(3/8) B No No Inside Pole 120'6'' - 5' 1 No Ice 0.00 0.08 WR-VG86ST- BRD(3/4) B No No Inside Pole 120'6'' - 5' 2 No Ice 0.00 0.58 840 10414(5/16) B No No Inside Pole 120'6'' - 0' 3 No Ice 0.00 0.06 *** LDF7-50A(1-5/8) C No No Inside Pole 96' - 5' 9 No Ice 0.00 0.82 *** CU12PSM9P6XXX (1-1/2) A No No Inside Pole 114' - 5' 1 No Ice 0.00 2.35 *** 5/8 rod/step C No No CaAa (Out Of Face) 120'6'' - 0' 1 No Ice 0.02 0.27 Safety Line 3/8 C No No CaAa (Out Of Face) 120'6'' - 0' 1 No Ice 0.04 0.22 *** August 13, 2021 120.5 Ft Monopole Tower Structural Analysis CCI BU No 813722 Project Number 1964296, Order 551657, Revision 1 Page 8 tnxTower Report - version 8.1.1.0 Feed Line/Linear Appurtenances Section Areas Tower Sectio n Tower Elevation ft Face AR ft2 AF ft2 CAAA In Face ft2 CAAA Out Face ft2 Weight K L1 120'6''-90'2- 1/32'' A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.744 0.06 0.33 0.06 L2 90'2-1/32''-45'8- 1/32'' A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.559 0.10 0.49 0.35 L3 45'8-1/32''-0' A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.626 0.10 0.45 0.32 Feed Line Center of Pressure Section Elevation ft CPX in CPZ in CPX Ice in CPZ Ice in L1 120'6''-90'2-1/32'' -0.4517 0.2608 -0.2625 0.1516 L2 90'2-1/32''-45'8- 1/32'' -0.4571 0.2639 -0.2643 0.1526 L3 45'8-1/32''-0' -0.4600 0.2656 -0.2653 0.1532 Note: For pole sections, center of pressure calculations do not consider feed line shielding. Discrete Tower Loads Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustmen t ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K Lighting Rod 3/4'' x 8' C From Leg 0.00 0' 5' 0.0000 121' No Ice 0.60 0.60 0.03 Top Hat 2' 3'' x 31.83'' C None 0.0000 121'9'' No Ice 2.98 2.98 0.10 *** (2) 800 10122 w/ Mount Pipe A From Leg 4.00 0' 2' 0.0000 121' No Ice 6.24 4.89 0.09 (2) 800 10122 w/ Mount Pipe B From Leg 4.00 0' 2' 0.0000 121' No Ice 6.24 4.89 0.09 (2) 800 10122 w/ Mount Pipe C From Leg 4.00 0' 2' 0.0000 121' No Ice 6.24 4.89 0.09 800 10764 w/ Mount Pipe A From Leg 3.00 0' 2' 0.0000 121' No Ice 4.33 3.12 0.07 800 10764 w/ Mount Pipe B From Leg 3.00 0' 2' 0.0000 121' No Ice 4.33 3.12 0.07 800 10764 w/ Mount Pipe C From Leg 3.00 0' 2' 0.0000 121' No Ice 4.33 3.12 0.07 TME-RRUS-11 A From Leg 3.00 0.0000 121' No Ice 2.96 1.67 0.06 August 13, 2021 120.5 Ft Monopole Tower Structural Analysis CCI BU No 813722 Project Number 1964296, Order 551657, Revision 1 Page 9 tnxTower Report - version 8.1.1.0 Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustmen t ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K 0' 2' TME-RRUS-11 B From Leg 3.00 0' 2' 0.0000 121' No Ice 2.96 1.67 0.06 TME-RRUS-11 C From Leg 3.00 0' 2' 0.0000 121' No Ice 2.96 1.67 0.06 TME-RRUS-11 A From Leg 3.00 0' 3' 0.0000 121' No Ice 2.96 1.67 0.06 TME-RRUS-11 B From Leg 3.00 0' 3' 0.0000 121' No Ice 2.96 1.67 0.06 TME-RRUS-11 C From Leg 3.00 0' 3' 0.0000 121' No Ice 2.96 1.67 0.06 ATM192012B-0 A From Leg 3.00 0' 2' 0.0000 121' No Ice 0.96 0.50 0.01 (2) ATM192012B-0 B From Leg 3.00 0' 2' 0.0000 121' No Ice 0.96 0.50 0.01 ATM192012B-0 C From Leg 3.00 0' 2' 0.0000 121' No Ice 0.96 0.50 0.01 ATM19801712-0 A From Leg 3.00 0' 2' 0.0000 121' No Ice 0.96 0.50 0.02 ATM19801712-0 C From Leg 3.00 0' 2' 0.0000 121' No Ice 0.96 0.50 0.02 (2) FDGW5504/3C-3L A From Leg 3.00 0' 2' 0.0000 121' No Ice 0.33 0.07 0.00 (2) FDGW5504/3C-3L B From Leg 3.00 0' 2' 0.0000 121' No Ice 0.33 0.07 0.00 (2) FDGW5504/3C-3L C From Leg 3.00 0' 2' 0.0000 121' No Ice 0.33 0.07 0.00 (4) 860 10025 A From Leg 3.00 0' 2' 0.0000 121' No Ice 0.14 0.12 0.00 (4) 860 10025 B From Leg 3.00 0' 2' 0.0000 121' No Ice 0.14 0.12 0.00 (4) 860 10025 C From Leg 3.00 0' 2' 0.0000 121' No Ice 0.14 0.12 0.00 DC6-48-60-18-8F B From Leg 3.00 0' 2' 0.0000 121' No Ice 1.21 1.21 0.02 Side Arm Mount [SO 101- 3] C None 0.0000 121' No Ice 5.81 5.81 0.25 Miscellaneous [NA 502-1] C None 0.0000 121' No Ice 3.36 5.41 0.22 *** (3) DB848H90E-XY w/ Mount Pipe A From Leg 3.00 0' 2' 0.0000 96' No Ice 4.63 7.08 0.07 (3) DB848H90E-XY w/ Mount Pipe B From Leg 3.00 0' 2' 0.0000 96' No Ice 4.63 7.08 0.07 (3) DB848H90E-XY w/ Mount Pipe C From Leg 3.00 0' 0.0000 96' No Ice 4.63 7.08 0.07 August 13, 2021 120.5 Ft Monopole Tower Structural Analysis CCI BU No 813722 Project Number 1964296, Order 551657, Revision 1 Page 10 tnxTower Report - version 8.1.1.0 Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustmen t ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K 2' Platform Mount [LP 303-1] C None 0.0000 96' No Ice 14.69 14.69 1.25 ***** MX08FRO665-21 w/ Mount Pipe A From Leg 4.00 0' 0' 0.0000 114' No Ice 8.01 4.23 0.11 MX08FRO665-21 w/ Mount Pipe B From Leg 4.00 0' 0' 0.0000 114' No Ice 8.01 4.23 0.11 MX08FRO665-21 w/ Mount Pipe C From Leg 4.00 0' 0' 0.0000 114' No Ice 8.01 4.23 0.11 TA08025-B604 A From Leg 4.00 0' 0' 0.0000 114' No Ice 1.96 0.98 0.06 TA08025-B604 B From Leg 4.00 0' 0' 0.0000 114' No Ice 1.96 0.98 0.06 TA08025-B604 C From Leg 4.00 0' 0' 0.0000 114' No Ice 1.96 0.98 0.06 TA08025-B605 A From Leg 4.00 0' 0' 0.0000 114' No Ice 1.96 1.13 0.08 TA08025-B605 B From Leg 4.00 0' 0' 0.0000 114' No Ice 1.96 1.13 0.08 TA08025-B605 C From Leg 4.00 0' 0' 0.0000 114' No Ice 1.96 1.13 0.08 RDIDC-9181-PF-48 B From Leg 4.00 0' 0' 0.0000 114' No Ice 2.31 1.29 0.02 (2) 8' x 2'' Mount Pipe A From Leg 4.00 0' 0' 0.0000 114' No Ice 1.90 1.90 0.03 (2) 8' x 2'' Mount Pipe B From Leg 4.00 0' 0' 0.0000 114' No Ice 1.90 1.90 0.03 (2) 8' x 2'' Mount Pipe C From Leg 4.00 0' 0' 0.0000 114' No Ice 1.90 1.90 0.03 Commscope MC-PK8-DSH C None 0.0000 114' No Ice 34.24 34.24 1.75 *** Load Combinations Comb. No. Description 1 Dead Only 2 1.2 Dead+1.0 Wind 0 deg - No Ice 3 0.9 Dead+1.0 Wind 0 deg - No Ice 4 1.2 Dead+1.0 Wind 30 deg - No Ice 5 0.9 Dead+1.0 Wind 30 deg - No Ice 6 1.2 Dead+1.0 Wind 60 deg - No Ice 7 0.9 Dead+1.0 Wind 60 deg - No Ice 8 1.2 Dead+1.0 Wind 90 deg - No Ice 9 0.9 Dead+1.0 Wind 90 deg - No Ice 10 1.2 Dead+1.0 Wind 120 deg - No Ice August 13, 2021 120.5 Ft Monopole Tower Structural Analysis CCI BU No 813722 Project Number 1964296, Order 551657, Revision 1 Page 11 tnxTower Report - version 8.1.1.0 Comb. No. Description 11 0.9 Dead+1.0 Wind 120 deg - No Ice 12 1.2 Dead+1.0 Wind 150 deg - No Ice 13 0.9 Dead+1.0 Wind 150 deg - No Ice 14 1.2 Dead+1.0 Wind 180 deg - No Ice 15 0.9 Dead+1.0 Wind 180 deg - No Ice 16 1.2 Dead+1.0 Wind 210 deg - No Ice 17 0.9 Dead+1.0 Wind 210 deg - No Ice 18 1.2 Dead+1.0 Wind 240 deg - No Ice 19 0.9 Dead+1.0 Wind 240 deg - No Ice 20 1.2 Dead+1.0 Wind 270 deg - No Ice 21 0.9 Dead+1.0 Wind 270 deg - No Ice 22 1.2 Dead+1.0 Wind 300 deg - No Ice 23 0.9 Dead+1.0 Wind 300 deg - No Ice 24 1.2 Dead+1.0 Wind 330 deg - No Ice 25 0.9 Dead+1.0 Wind 330 deg - No Ice 26 Dead+Wind 0 deg - Service 27 Dead+Wind 30 deg - Service 28 Dead+Wind 60 deg - Service 29 Dead+Wind 90 deg - Service 30 Dead+Wind 120 deg - Service 31 Dead+Wind 150 deg - Service 32 Dead+Wind 180 deg - Service 33 Dead+Wind 210 deg - Service 34 Dead+Wind 240 deg - Service 35 Dead+Wind 270 deg - Service 36 Dead+Wind 300 deg - Service 37 Dead+Wind 330 deg - Service Maximum Member Forces Sectio n No. Elevation ft Component Type Condition Gov. Load Comb. Axial K Major Axis Moment kip-ft Minor Axis Moment kip-ft L1 120.5 - 90.1693 Pole Max Tension 1 0.00 0.00 0.00 Max. Compression 4 -10.10 -168.52 291.62 Max. Mx 8 -10.09 -337.87 -0.65 Max. My 14 -10.10 -0.63 -337.27 Max. Vy 8 19.76 -337.87 -0.65 Max. Vx 14 19.73 -0.63 -337.27 Max. Torque 4 -0.77 L2 90.1693 - 45.6719 Pole Max Tension 1 0.00 0.00 0.00 Max. Compression 4 -20.79 -656.37 1136.63 Max. Mx 8 -20.79 -1315.64 -1.87 Max. My 14 -20.79 -1.79 -1313.72 Max. Vy 8 27.03 -1315.64 -1.87 Max. Vx 14 27.00 -1.79 -1313.72 Max. Torque 18 0.70 L3 45.6719 - 0 Pole Max Tension 1 0.00 0.00 0.00 Max. Compression 4 -43.40 -1508.41 2612.48 Max. Mx 20 -43.40 3022.34 3.04 Max. My 14 -43.40 -3.21 -3018.79 Max. Vy 20 -37.45 3022.34 3.04 Max. Vx 14 37.42 -3.21 -3018.79 Max. Torque 20 0.90 Maximum Reactions Location Condition Gov. Load Comb. Vertical K Horizontal, X K Horizontal, Z K Pole Max. Vert 4 43.41 -18.70 32.38 August 13, 2021 120.5 Ft Monopole Tower Structural Analysis CCI BU No 813722 Project Number 1964296, Order 551657, Revision 1 Page 12 tnxTower Report - version 8.1.1.0 Location Condition Gov. Load Comb. Vertical K Horizontal, X K Horizontal, Z K Max. Hx 21 32.56 37.44 0.03 Max. Hz 3 32.56 0.03 37.41 Max. Mx 2 3018.43 0.03 37.41 Max. Mz 8 3022.32 -37.44 -0.03 Max. Torsion 20 0.90 37.44 0.03 Min. Vert 9 32.56 -37.44 -0.03 Min. Hx 9 32.56 -37.44 -0.03 Min. Hz 15 32.56 -0.03 -37.41 Min. Mx 14 -3018.79 -0.03 -37.41 Min. Mz 20 -3022.34 37.44 0.03 Min. Torsion 8 -0.90 -37.44 -0.03 Tower Mast Reaction Summary Load Combination Vertical K Shearx K Shearz K Overturning Moment, Mx kip-ft Overturning Moment, Mz kip-ft Torque kip-ft Dead Only 36.18 0.00 0.00 0.15 0.01 0.00 1.2 Dead+1.0 Wind 0 deg - No Ice 43.41 -0.03 -37.41 -3018.43 3.23 -0.15 0.9 Dead+1.0 Wind 0 deg - No Ice 32.56 -0.03 -37.41 -3012.45 3.22 -0.15 1.2 Dead+1.0 Wind 30 deg - No Ice 43.41 18.70 -32.38 -2612.48 -1508.41 0.32 0.9 Dead+1.0 Wind 30 deg - No Ice 32.56 18.70 -32.38 -2607.29 -1505.39 0.32 1.2 Dead+1.0 Wind 60 deg - No Ice 43.41 32.41 -18.68 -1506.38 -2615.87 0.70 0.9 Dead+1.0 Wind 60 deg - No Ice 32.56 32.41 -18.68 -1503.41 -2610.63 0.70 1.2 Dead+1.0 Wind 90 deg - No Ice 43.41 37.44 0.03 3.40 -3022.32 0.90 0.9 Dead+1.0 Wind 90 deg - No Ice 32.56 37.44 0.03 3.35 -3016.29 0.90 1.2 Dead+1.0 Wind 120 deg - No Ice 43.41 32.44 18.73 1512.32 -2619.09 0.85 0.9 Dead+1.0 Wind 120 deg - No Ice 32.56 32.44 18.73 1509.25 -2613.85 0.85 1.2 Dead+1.0 Wind 150 deg - No Ice 43.41 18.74 32.41 2616.06 -1513.99 0.58 0.9 Dead+1.0 Wind 150 deg - No Ice 32.56 18.74 32.41 2610.78 -1510.96 0.58 1.2 Dead+1.0 Wind 180 deg - No Ice 43.41 0.03 37.41 3018.79 -3.21 0.15 0.9 Dead+1.0 Wind 180 deg - No Ice 32.56 0.03 37.41 3012.72 -3.21 0.15 1.2 Dead+1.0 Wind 210 deg - No Ice 43.41 -18.70 32.38 2612.84 1508.43 -0.32 0.9 Dead+1.0 Wind 210 deg - No Ice 32.56 -18.70 32.38 2607.56 1505.41 -0.32 1.2 Dead+1.0 Wind 240 deg - No Ice 43.41 -32.41 18.68 1506.74 2615.89 -0.70 0.9 Dead+1.0 Wind 240 deg - No Ice 32.56 -32.41 18.68 1503.68 2610.65 -0.70 1.2 Dead+1.0 Wind 270 deg - No Ice 43.41 -37.44 -0.03 -3.04 3022.34 -0.90 0.9 Dead+1.0 Wind 270 deg - No Ice 32.56 -37.44 -0.03 -3.08 3016.31 -0.90 1.2 Dead+1.0 Wind 300 deg - No Ice 43.41 -32.44 -18.73 -1511.96 2619.12 -0.85 0.9 Dead+1.0 Wind 300 deg - No Ice 32.56 -32.44 -18.73 -1508.98 2613.87 -0.85 1.2 Dead+1.0 Wind 330 deg - No Ice 43.41 -18.74 -32.41 -2615.70 1514.01 -0.57 August 13, 2021 120.5 Ft Monopole Tower Structural Analysis CCI BU No 813722 Project Number 1964296, Order 551657, Revision 1 Page 13 tnxTower Report - version 8.1.1.0 Load Combination Vertical K Shearx K Shearz K Overturning Moment, Mx kip-ft Overturning Moment, Mz kip-ft Torque kip-ft 0.9 Dead+1.0 Wind 330 deg - No Ice 32.56 -18.74 -32.41 -2610.51 1510.98 -0.57 Dead+Wind 0 deg - Service 36.18 -0.00 -5.28 -425.46 0.46 -0.02 Dead+Wind 30 deg - Service 36.18 2.64 -4.57 -368.21 -212.66 0.05 Dead+Wind 60 deg - Service 36.18 4.57 -2.64 -212.26 -368.80 0.10 Dead+Wind 90 deg - Service 36.18 5.28 0.00 0.60 -426.12 0.13 Dead+Wind 120 deg - Service 36.18 4.58 2.64 213.35 -369.26 0.12 Dead+Wind 150 deg - Service 36.18 2.65 4.57 368.96 -213.45 0.08 Dead+Wind 180 deg - Service 36.18 0.00 5.28 425.76 -0.44 0.02 Dead+Wind 210 deg - Service 36.18 -2.64 4.57 368.51 212.68 -0.05 Dead+Wind 240 deg - Service 36.18 -4.57 2.64 212.56 368.82 -0.10 Dead+Wind 270 deg - Service 36.18 -5.28 -0.00 -0.30 426.14 -0.13 Dead+Wind 300 deg - Service 36.18 -4.58 -2.64 -213.05 369.28 -0.12 Dead+Wind 330 deg - Service 36.18 -2.65 -4.57 -368.66 213.47 -0.08 Solution Summary Load Comb. Sum of Applied Forces Sum of Reactions % Error PX K PY K PZ K PX K PY K PZ K 1 0.00 -36.18 0.00 0.00 36.18 0.00 0.000% 2 -0.03 -43.41 -37.41 0.03 43.41 37.41 0.002% 3 -0.03 -32.56 -37.41 0.03 32.56 37.41 0.002% 4 18.70 -43.41 -32.38 -18.70 43.41 32.38 0.000% 5 18.70 -32.56 -32.38 -18.70 32.56 32.38 0.000% 6 32.41 -43.41 -18.68 -32.41 43.41 18.68 0.000% 7 32.41 -32.56 -18.68 -32.41 32.56 18.68 0.000% 8 37.44 -43.41 0.03 -37.44 43.41 -0.03 0.002% 9 37.44 -32.56 0.03 -37.44 32.56 -0.03 0.002% 10 32.44 -43.41 18.73 -32.44 43.41 -18.73 0.000% 11 32.44 -32.56 18.73 -32.44 32.56 -18.73 0.000% 12 18.74 -43.41 32.41 -18.74 43.41 -32.41 0.000% 13 18.74 -32.56 32.41 -18.74 32.56 -32.41 0.000% 14 0.03 -43.41 37.41 -0.03 43.41 -37.41 0.002% 15 0.03 -32.56 37.41 -0.03 32.56 -37.41 0.002% 16 -18.70 -43.41 32.38 18.70 43.41 -32.38 0.000% 17 -18.70 -32.56 32.38 18.70 32.56 -32.38 0.000% 18 -32.41 -43.41 18.68 32.41 43.41 -18.68 0.000% 19 -32.41 -32.56 18.68 32.41 32.56 -18.68 0.000% 20 -37.44 -43.41 -0.03 37.44 43.41 0.03 0.002% 21 -37.44 -32.56 -0.03 37.44 32.56 0.03 0.002% 22 -32.44 -43.41 -18.73 32.44 43.41 18.73 0.000% 23 -32.44 -32.56 -18.73 32.44 32.56 18.73 0.000% 24 -18.74 -43.41 -32.41 18.74 43.41 32.41 0.000% 25 -18.74 -32.56 -32.41 18.74 32.56 32.41 0.000% 26 -0.00 -36.18 -5.28 0.00 36.18 5.28 0.002% 27 2.64 -36.18 -4.57 -2.64 36.18 4.57 0.002% 28 4.58 -36.18 -2.64 -4.57 36.18 2.64 0.002% 29 5.29 -36.18 0.00 -5.28 36.18 -0.00 0.002% 30 4.58 -36.18 2.64 -4.58 36.18 -2.64 0.002% 31 2.65 -36.18 4.58 -2.65 36.18 -4.57 0.002% 32 0.00 -36.18 5.28 -0.00 36.18 -5.28 0.002% 33 -2.64 -36.18 4.57 2.64 36.18 -4.57 0.002% 34 -4.58 -36.18 2.64 4.57 36.18 -2.64 0.002% 35 -5.29 -36.18 -0.00 5.28 36.18 0.00 0.002% 36 -4.58 -36.18 -2.64 4.58 36.18 2.64 0.002% 37 -2.65 -36.18 -4.58 2.65 36.18 4.57 0.002% August 13, 2021 120.5 Ft Monopole Tower Structural Analysis CCI BU No 813722 Project Number 1964296, Order 551657, Revision 1 Page 14 tnxTower Report - version 8.1.1.0 Non-Linear Convergence Results Load Combination Converged? Number of Cycles Displacement Tolerance Force Tolerance 1 Yes 6 0.00000001 0.00000001 2 Yes 8 0.00000001 0.00010400 3 Yes 8 0.00000001 0.00008860 4 Yes 9 0.00000001 0.00007242 5 Yes 9 0.00000001 0.00005884 6 Yes 9 0.00000001 0.00006426 7 Yes 9 0.00000001 0.00005209 8 Yes 8 0.00000001 0.00010563 9 Yes 8 0.00000001 0.00008989 10 Yes 9 0.00000001 0.00007073 11 Yes 9 0.00000001 0.00005741 12 Yes 9 0.00000001 0.00006911 13 Yes 9 0.00000001 0.00005607 14 Yes 8 0.00000001 0.00010427 15 Yes 8 0.00000001 0.00008881 16 Yes 9 0.00000001 0.00006460 17 Yes 9 0.00000001 0.00005237 18 Yes 9 0.00000001 0.00007296 19 Yes 9 0.00000001 0.00005929 20 Yes 8 0.00000001 0.00010527 21 Yes 8 0.00000001 0.00008961 22 Yes 9 0.00000001 0.00006691 23 Yes 9 0.00000001 0.00005426 24 Yes 9 0.00000001 0.00006834 25 Yes 9 0.00000001 0.00005545 26 Yes 7 0.00000001 0.00008947 27 Yes 7 0.00000001 0.00008822 28 Yes 7 0.00000001 0.00008826 29 Yes 7 0.00000001 0.00008970 30 Yes 7 0.00000001 0.00008852 31 Yes 7 0.00000001 0.00008846 32 Yes 7 0.00000001 0.00008959 33 Yes 7 0.00000001 0.00008824 34 Yes 7 0.00000001 0.00008833 35 Yes 7 0.00000001 0.00008963 36 Yes 7 0.00000001 0.00008839 37 Yes 7 0.00000001 0.00008832 Maximum Tower Deflections - Service Wind Section No. Elevation ft Horz. Deflection in Gov. Load Comb. Tilt ° Twist ° L1 120.5 - 90.1693 2.950 30 0.2420 0.0005 L2 95.0026 - 45.6719 1.766 30 0.1894 0.0002 L3 52.9193 - 0 0.512 30 0.0908 0.0000 Critical Deflections and Radius of Curvature - Service Wind Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt ° Twist ° Radius of Curvature ft 121'9'' Top Hat 2' 3'' x 31.83'' 30 2.950 0.2420 0.0005 105662 121' Lighting Rod 3/4'' x 8' 30 2.950 0.2420 0.0005 105662 114' MX08FRO665-21 w/ Mount Pipe 30 2.633 0.2292 0.0004 81278 August 13, 2021 120.5 Ft Monopole Tower Structural Analysis CCI BU No 813722 Project Number 1964296, Order 551657, Revision 1 Page 15 tnxTower Report - version 8.1.1.0 Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt ° Twist ° Radius of Curvature ft 96' (3) DB848H90E-XY w/ Mount Pipe 30 1.808 0.1917 0.0002 21976 Maximum Tower Deflections - Design Wind Section No. Elevation ft Horz. Deflection in Gov. Load Comb. Tilt ° Twist ° L1 120.5 - 90.1693 20.907 10 1.7144 0.0034 L2 95.0026 - 45.6719 12.524 10 1.3430 0.0012 L3 52.9193 - 0 3.632 10 0.6437 0.0003 Critical Deflections and Radius of Curvature - Design Wind Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt ° Twist ° Radius of Curvature ft 121'9'' Top Hat 2' 3'' x 31.83'' 10 20.907 1.7144 0.0034 14966 121' Lighting Rod 3/4'' x 8' 10 20.907 1.7144 0.0034 14966 114' MX08FRO665-21 w/ Mount Pipe 10 18.664 1.6235 0.0028 11512 96' (3) DB848H90E-XY w/ Mount Pipe 10 12.819 1.3587 0.0012 3112 Compression Checks Pole Design Data Section No. Elevation ft Size L ft Lu ft Kl/r A in2 Pu K IPn K Ratio Pu IPn L1 120.5 - 90.1693 (1) TP37.405x24x0.25 30'3- 31/32'' 0' 0.0 27.787 5 -10.09 1625.57 0.006 L2 90.1693 - 45.6719 (2) TP56.569x34.7689x0.375 49'3- 31/32'' 0' 0.0 63.072 8 -20.79 3689.76 0.006 L3 45.6719 - 0 (3) TP76x52.6162x0.4375 52'11- 1/32'' 0' 0.0 104.92 80 -43.40 6138.29 0.007 Pole Bending Design Data Section No. Elevation ft Size Mux kip-ft IMnx kip-ft Ratio Mux IMnx Muy kip-ft IMny kip-ft Ratio Muy IMny L1 120.5 - 90.1693 (1) TP37.405x24x0.25 338.24 1319.77 0.256 0.00 1319.77 0.000 L2 90.1693 - 45.6719 (2) TP56.569x34.7689x0.375 1316.74 4517.54 0.291 0.00 4517.54 0.000 L3 45.6719 - 0 (3) TP76x52.6162x0.4375 3024.36 9774.42 0.309 0.00 9774.42 0.000 August 13, 2021 120.5 Ft Monopole Tower Structural Analysis CCI BU No 813722 Project Number 1964296, Order 551657, Revision 1 Page 16 tnxTower Report - version 8.1.1.0 Pole Shear Design Data Section No. Elevation ft Size Actual Vu K IVn K Ratio Vu IVn Actual Tu kip-ft ITn kip-ft Ratio Tu ITn L1 120.5 - 90.1693 (1) TP37.405x24x0.25 19.78 487.67 0.041 0.17 1495.58 0.000 L2 90.1693 - 45.6719 (2) TP56.569x34.7689x0.375 27.05 1106.93 0.024 0.44 5136.93 0.000 L3 45.6719 - 0 (3) TP76x52.6162x0.4375 37.47 1841.49 0.020 0.85 12185.83 0.000 Pole Interaction Design Data Section No. Elevation ft Ratio Pu IPn Ratio Mux IMnx Ratio Muy IMny Ratio Vu IVn Ratio Tu ITn Comb. Stress Ratio Allow. Stress Ratio Criteria L1 120.5 - 90.1693 (1) 0.006 0.256 0.000 0.041 0.000 0.264 1.050 4.8.2 L2 90.1693 - 45.6719 (2) 0.006 0.291 0.000 0.024 0.000 0.298 1.050 4.8.2 L3 45.6719 - 0 (3) 0.007 0.309 0.000 0.020 0.000 0.317 1.050 4.8.2 Section Capacity Table Section No. Elevation ft Component Type Size Critical Element P K øPallow K % Capacity Pass Fail L1 120.5 - 90.1693 Pole TP37.405x24x0.25 1 -10.09 1706.85 25.2 Pass L2 90.1693 - 45.6719 Pole TP56.569x34.7689x0.375 2 -20.79 3874.25 28.4 Pass L3 45.6719 - 0 Pole TP76x52.6162x0.4375 3 -43.40 6445.20 30.2 Pass Summary Pole (L3) 30.2 Pass RATING = 30.2 Pass August 13, 2021 120.5 Ft Monopole Tower Structural Analysis CCI BU No 813722 Project Number 1964296, Order 551657, Revision 1 Page 17 tnxTower Report - version 8.1.1.0 APPENDIX B BASE LEVEL DRAWING August 13, 2021 120.5 Ft Monopole Tower Structural Analysis CCI BU No 813722 Project Number 1964296, Order 551657, Revision 1 Page 18 tnxTower Report - version 8.1.1.0 APPENDIX C ADDITIONAL CALCULATIONS Monopole Base Plate Connection *TIA-222-H Section 15.5 Applied #VALUE! Anchor Rod Data Anchor Rod Summary (units of kips, kip-in) (28) 2-1/4" ø bolts (A615-75 N; Fy=75 ksi, Fu=100 ksi) on 83" BC Pu_c = 64 φPn_c = 268.39 Stress Rating Vu = 1.34 φVn = 120.77 24.8% Base Plate Data Mu = 2.83 φMn = 128.14 Pass 89" OD x 2.75" Plate (A633 Gr. E; Fy=60 ksi, Fu=70 ksi) Base Plate Summary Stiffener Data Max Stress (ksi): 8.78 (Flexural) N/A Allowable Stress (ksi): 54 Stress Rating:15.5%Pass Pole Data 76" x 0.4375" 18-sided pole (A572-65; Fy=65 ksi, Fu=80 ksi) 43.40 37.47 Adjusted Pole Reactions BU # 813722 Applied Loads Site Name W INDRIO BRA351 Order # 551657 Rev. 1 Analysis Considerations Site Info TIA-222 Revision H Grout Considered:No Analysis ResultsConnection Properties Iar (in) 3.25 Moment (kip-ft) 3024.36 Axial Force (kips) 43.40 Shear Force (kips) 37.47 Moment (kip-ft) Axial Force (kips) Shear Force (kips) 0.00 Analysis Date: 8/13/2021CCIplate - Version 4.1.2 Select Select BU # : Monopole Base Reaction Comparison Test MOMENT (kip-ft)37.9% % CAPACITY Component:Monopole Base 5635.0 7607.3 3024.4 Design TIA: TIA-222-F Compared To TIA-222-H DESIGN REACTIONS *MODIFIED DESIGN REACTIONS CURRENT REACTIONS TIA-222-F 813722 Deisgn loads from: CCIsites Doc #216137 Although the shear capacity is at 42.0%, the moment reaction is the governing criteria for a monopole drilled pier foundation. Therefore, the overall capacity for this foundation is 37.9%. 216137 Order Number: Site Name: Current TIA:TIA-222-H SHEAR (kips)62.9 84.9 37.5 42.0% MONOPOLE BASE FOUNDATION REACTION COMPARISON REACTIONS W INDRIO BRA351 Reference Doc ID: 551657 Rev. 1 *Design loads were multiplied by 1.35 for comparison as allowed by TIA-222-H, Section 15.6. Version 3.0.0 ASCE 7 Hazards Report Address: No Address at This Location Standard:ASCE/SEI 7-16 Risk Category:II Soil Class:D - Default (see Section 11.4.3) Elevation:19.81 ft (NAVD 88) Latitude: Longitude: 27.526028 -80.455472 Wind Results: Wind Speed: 155 Vmph 10-year MRI 86 Vmph 25-year MRI 105 Vmph 50-year MRI 117 Vmph 100-year MRI 128 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Fri Aug 13 2021 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Glazed openings shall be protected against wind-borne debris as specified in Section 26.12.3. Page 1 of 3https://asce7hazardtool.online/Fri Aug 13 2021 SS : 0.051 S1 : 0.028 F a :1.6 F v :2.4 SMS : 0.081 SM1 : 0.068 SDS : 0.054 S D1 :0.046 T L :8 PGA : 0.024 PGA M :0.038 F PGA :1.6 Ie :1 C v :0.7 Design Response SpectrumDesign Response Spectrum S (g) vs T(s)a MCE Response SpectrumRMCE Response Spectrum S (g) vs T(s)a Design Vertical Response SpectrumDesign Vertical Response Spectrum S (g) vs T(s)a MCE Vertical Response SpectrumRMCE Vertical Response Spectrum S (g) vs T(s)a Seismic Site Soil Class: Results: Seismic Design Category D - Default (see Section 11.4.3) A Data Accessed: Date Source: Fri Aug 13 2021 USGS Seismic Design Maps based on ASCE/SEI 7-16 and ASCE/SEI 7-16 Table 1.5-2. Additional data for site-specific ground motion procedures in accordance with ASCE/SEI 7-16 Ch. 21 are available from USGS. Page 2 of 3https://asce7hazardtool.online/Fri Aug 13 2021 Ice Results: Data Source: Date Accessed: Ice Thickness: 0.00 in. Concurrent Temperature: 25 F Gust Speed: 30 mph Standard ASCE/SEI 7-16, Figs. 10-2 through 10-8 Fri Aug 13 2021 Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds, for a 500-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain. Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. Page 3 of 3https://asce7hazardtool.online/Fri Aug 13 2021