Architects 10-11-16
ELECTRICAL LEGEND ELEU I RK AL NOTES REVISIONS BY DATE PERMIT SETS SH 8.29.2016 STRUCTURAL COORC SH 9.7.2016 PHONEJACK ELECTRIC METER WF WALL MOUNTED FIXTURE DOUBLE CAT 5e CABLE O ELECTRIC PANEL ❑D DISCONNECT F 4- CEILING MOUNTED FIXTURE tv VIDEO OUTLET CV CENTRAL VAC. HOSE OUTLET ® 220 VOLT RECEPTACLE WJ WALL MOUNTED J-BOX O EXHAUST FAN SINGLE OUTLET O SMOKE DETECTOR DUPLEX OUTLET CJ CEILING MOUNTED J-BOX T O THERMOSTAT DUPLEX OUTLET -HALF SWITCHED ST SPRINKLER TIMER GF :@r G.F.C.I. PROTECTED OUTLET -(PC"-PULL CORD FIXTURE 'I OINTERCOM WPGF � WEATHER PROOF GFCI OUTLET ® DUPLEX FLOOR OUTLET 6RECESSED ADJUSTABLE FIXTURE kp KEYPAD WALL SWITCH [3 RECESSED LIGHT FIXTURE MOTION DETECTOR -b9-3 3-WAY WALL SWITCH VP ® VAPOR PROOF RECESSED FIXTURE -69-4 4-WAY WALL SWITCH / FLUURESCENT LIGHT FIXTURE D DIMMER WALL SWITCH CEILING FAN APB PUSH BUTTON SWITCH FLOOD/SECURITY LIGHTS / '--' UNDER CABINET FIXTURE ELECTRICAL RISER DIAGRAM ELECTRICAL METER & MAIN DISCONNECT AF=] 150AMP 150A 150A 0 PANEL PANEL g= B A METER 150AMP 40 CKTS 40 CKTS M.L.O. M.L.O. A.I.C. A.I.C. 10,000 10,000 (2) #6, 1 #6 NEUTRAL, UNDERGROUND TO FP&L TIE-IN LOCATION POOL PANE 60 AMP M.L.O. (3) #2/0 CU &(1)#6 (1) #2 CU TO 5/8" GROUNDING ROD IN 2" C. & TO FOOTER STEAL (1) 42 CU. GND. WIRE TO H2O PNL AMPS VOLTAGE CKTS WIRE PHASE A 150 120/240 42 3 1 1 CIR # WIRE POLE AMPS SERVING KW I CIR # WIRE POLE AMPS SERVING KW 1 6 2 60 AHU #1 10.0 2 6 2 50 ACCU #1 - 3 4 5 10 2 30 DRYER 4.5 6 6 2 50 OVENS 5.4 7 8 9 12 1 20 COOKTOP HOOD 1.5 10 12 1 20 GARAGE DR OPENER 1.5 11 12 1 20 SMALL APPLIANCE #1 1.5 12 12 1 20 BATH GFI'S #1 1.5 13 12 1 20 WETBAR REF 1.2 14 12 1 20 WETBAR ICE 1.2 15 SPACE 16 12 1 20 CEN VAC 1.2 17 SPACE 18 SPACE 19 14 1 15 GEN'L LIGHTING ** 20 14 1 15 GEN'L LIGHTING ** 21 14 1 15 GEN'L LIGHTING ** 22 14 1 15 GEN'L LIGHTING ** 23 14 1 15 GEN'L LIGHTING ** 24 14 1 15 GEN'L LIGHTING ** 25 14 1 15 GEN'L LIGHTING ** 26 14 1 15 GEN'L LIGHTING ** 27 14 1 15 GEN'L LIGHTING ** 28 14 1 15 GEN'L LIGHTING ** 29 14 1 15 GEN'L LIGHTING ** 30 14 1 15 GEN'L LIGHTING ** 31 14 1 15 GEN'L LIGHTING ** 32 14 1 15 GEN'L LIGHTING ** 33 SPACE 34 SPACE 35 36 37 38 39 40 41 42 PANEL'A' LOAD CALCULATIONS 1st 10.0 KW @ 100% 10.0 LARGEST OF: HEATING @ 65% 6.5 COOLING @ 100% REMAINING KW @ 40% 6.8 TOTAL KW 23.3 ** GEN. UTING (2,506 SF @ 3W/SF) 7.5 PANEL A TOTAL KW = 37.0 23,300 W. = 97.1 Amps 240 V. PNL AMPS VOLTAGE CKTS WIRE PHASE B 150 120/240 42 3 1 CIRftj WIRE POLE AMPS SERVING KW CIR # WIRE POLE AMPS SERVING KW 1 6 2 60 AHU #2 10.0 2 10 2 30 ELEVATOR 10 3 4 5 6 2 60 ACCU #2 6 12 2 20 DW & DISP 91 2.2 7 8 9 6 2 60 AHU #3 10.0 10 6 2 60 ACCU #3 - 11 12 13 12 1 20 COOKTOP IGNITER 0.5 14 12 1 20 WASHER 1.2 15 12 1 20 W/H IGNITER 0.5 16 12 1 20 KIT REF 1.5 17 12 1 20 RECIRCULATING PUMP 1.2 18 12 1 20 BATH GFI'S #2 1.5 19 10 2 30 STACK WA/DRYER 4.5 20 12 1 20 SMALL APPLIANCE #2 1.5 21 22 12 1 20 MORNING BAR REF 1.2 23 14 1 15 GEN'L LIGHTING ** 24 14 1 15 GEN'L LIGHTING ** 25 14 1 15 GEN'L LIGHTING ** 26 14 1 15 GEN'L LIGHTING ** 27 14 1 15 GEN'L LIGHTING ** 28 14 1 15 GEN'L LIGHTING ** 29 14 1 15 GEN'L LIGHTING ** 30 14 1 15 GEN'L LIGHTING ** 31 14 1 15 GEN'L LIGHTING ** 32 14 1 15 GEN'L LIGHTING ** 33 14 1 15 GEN'L LIGHTING ** 34 14 1 15 GEN'L LIGHTING ** 35 14 1 15 GEN'L LIGHTING ** 36 14 1 15 GEN'L LIGHTING ** 37 SPACE 38 SPACE 39 40 41 42 ** GEN. UTING (2,506 SF @ 3W/SF) 7.5 PANEL'B' LOAD CALCULATIONS PANEL B TOTAL KW = 46.3 1 st 10.0 KW @ 100% 10.0 LARGEST OF: HEATING @ 65% 13.0 COOLING @ 100% REMAINING KW @ 40% 6.5 TOTAL KW 29.5 29,500 W. = 122.9 240 V. Amps GENERAL: 1) CONTRACTOR SHALL VERIFY THE LOCATION OF SERVICE AND SHALL LOCATE THE METER & PANELS AS REQUIRED. 2) ALL WIRE SHALL BE THHN COPPER, UNLESS NOTED OTHERWISE. 3) WHERE REQUIRED BY OTHER CODES, SERVICE AND FEEDER CONDUCTORS SHALL BE COPPER OF EQUAL AMPACITY. 4) ALL BRANCH CIRCUITS IN RACEWAY OR NON METALLIC SHEATHED CABLE 5) COORDINATE RACEWAY INSTALLATIONS WITH OTHER TRADES PRIOR TO CONSTRUCTION. 6) ROMEX MAY BE USED WHERE CONDUIT IS NOT REQUIRED. 7) BX CABLE MAY BE USED IN LIEU OF RIGID CONDUIT. 8) VERIFY ALL CONDUCTORS AND BREAKERS WITH EQUIPMENT MANUFACTURER SPECIFICATIONS. 9) PROVIDE DISCONNECT SWITCHES OF SIZE AS REQUIRED BY LOADS. 10) PROVIDE NON -FUSIBLE GENERAL DUTY SAFETY SWITCHES AT A/C EQUIP AND AT PUMPS NOT VISIBLE FROM CIRCUIT BREAKER PANEL AND AS PER MANUFACTURER RECOMMENDATIONS, 11) PROVIDE DISCONNECTS FOR POOL PUMP PER N.E.C. 680. POOL CONTRACTOR SHALL PROVIDE ELECTRICAL CONTRACTOR WITH ALL LOADS PRIOR TO INSTALLATION. ELECTRICAL CONTRACTOR TO MAKE ALL CONNECTIONS PER POOL COMPANY DRAWINGS. VERIFY LOCATION OF ALL POOL/SPA EQIUPMENT. 12) ALL 120 VOLT 15 AND 20 AMP CIRCUITS THAT SERVE FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, REC ROOMS, CLOSETS, HALLWAYS, OR SIMILIAR ROOMS TO BE ARC FAULT CIRCUIT PROTECTED PER FBCR E3902.12. 13) WIRES SMALLER THAN #6 SHALL HAVE THHN INSULATION, #6 & LARGER SHALL HAVE THWN INSULATION. FIXTURES: 1) PROVIDE GREEN WIRE GROUND TO ALL EXTERIOR FIXTURES AND "J" BOXES. 2) ELECTRICAL FIXTURES, TRIM AND APPLIANCES SHALL BE UL APPROVED AND AS SELECTED BY OWNER. 3) ALL LIGHTING FIXTURES AND FANS TO BE SELECTED & LOCATED BY OWNER/ARCHITECT/INTERIOR DESIGNER, UNLESS OTHERWISE NOTED. 4) ARCHITECT TO SET MOUNTING HEIGHTS FOR ALL FIXTURES WHERE APPLICABLE, UNLESS OTHERWISE NOTED. 5) FLUORESCENT CLOSET LIGHT FIXTURES SHALL HAVE A MINIMUM CLEARANCE OF 6" AWAY FROM CLOTHING. 6) PREWIRE FOR GARAGE DOOR OPENER SENSOR. 7) HIHATS TO BE 4" ROUND OUTLETS: 1) ALL COUNTERTOP RECEPTACLES SHALL BE GFCI OUTLETS. 2) PROVIDE GFCI BREAKERS FOR ALL BATHROOMS, GARAGE AND EXTERIOR OUTLETS AS SHOWN ON PLANS. 3) ALL 125 VOLT 15 AND 20 AMP RECEPTACLES TO BE TAMPER RESISTANT PER FBCR E3902.12. 4) PROVIDE PRE -WIRED TELEPHONE & CABLE T.V. OUTLETS AS SHOWN ON PLAN. PROVIDE OPTIONAL PRE -WIRED HIGHSPEED DATA OUTLETS AS SHOWP ON PLANS. (IF APPLICABLE) 5) FOR FLOOR RECEPTACLES, PROVIDE A COVER PLATE AND FLUSH WITH FLOOR. VERIFY EXACT LOCATION WITH GC/OWNER. PROVIDE 1/2" CONDUIT UNDER SLAB FROM WALL. SMOKE DETECTORS: 1) ALL SMOKE DETECTORS TO HAVE BATTERY BACK UP AND SIGNAL SIMULTANEOUSLY W/ TEMPORAL SOUND. 2) SMOKE DETECTORS TO BE LOCATED MIN 3'-0" FROM: R/A & SUPPLY GRILLS KITCHENS, BATH ROOMS. 3) SMOKE DETECTORS TO BE COMBINATION TYPE CARBON MONOXIDE ALARK & SMOKE DETECTOR. ELEVATOR NOTES: 1. ELEVATOR SHALL MEET NEC 620 22-23; VERIFY LOCATION AND ELECTRICAL REQUIREMENTS OF ELEVATOR EQUIPMENT WITH MFG SPECS PRIOR TO CONSTRUCTION. 2. IF THERE IS AN ELEVATOR PIT LOCATED BELOW, PROVIDE WITH FLOAT SWITCH SENSOR; LIGHT FIXTURE SHALL NOT BE INSTALLED IN ELEVATOR PIT 3. PROVIDE A LIGHTING FIXTURE WITH RECEPTACLE OUTLET, CONTROLLED BY A SWITCH LOCATED AT THE PASSAGEWAY OPENING PER FMC 306.3.1. PNL JAMPS1 VOLTAGE CKTS WIRE PHASE P (POOL) 1 60 1 120/240 1 12 3 1 1 CIR # WIRE POLE AMPS SERVING KW CIR # WIRE POLE AMPS SERVING KW 1 2 12 1 20 POOL LIGHTS 0.8 8 2 40 POOL PUMP 1.5 3 4 12 1 20 POOL HEATER IGNITER 0.5 5 SPACE 6 12 1 20 POOL CONTROLLER 0.5 7 8 SPACE 9 10 11 12 PANEL P TOTAL KW = 3.3 PANEL'P' LOAD CALCULATIONS 1st 10.0 KW @ 100% 3.3 LARGEST OF: 0.0 HEATING @ 65% (6.5 KW) 3,300 W. COOLING @ 100% (KW) = 13.8 Amps REMAINING KW A 40% 240 V. TOTAL KW 3.3 101 I f WA DR CF j' I L �I I ! @ +6Q" (VERIFY HT.) W/ BACKING FOR TV MOUNT ! TO UPP5F(---- FLOOR SWITCH FOR DW & DISP if t ELECTRIC METER Cid ELECTRIC PANEL [] DISCONNECT 220 VOLT RECEPTACLE SINGLE OUTLET DUPLEX OUTLET DUPLEX OUTLET - HALF SWITCHED GF 2@-_ G.F.C.I. PROTECTED OUTLET WPGF 4D- WEATHER PROOF GFCI OUTLET RNDUPLEX FLOOR OUTLET -Efl- WALL SWITCH -&w-3 3-WAY WALL SWITCH �4 4-WAY WALL SWITCH -69-D DIMMER WALL SWITCH APB PUSH BUTTON SWITCH ELECTRICAL LEGEND WF WALL MOUNTED FIXTURE CF CEILING MOUNTED FIXTURE WJ WALL MOUNTED J-BOX CJ CEILING MOUNTED J-BOX L 4P /- 1 PULL CORD FIXTURE aRECESSED ADJUSTABLE FIXTURE ® RECESSED LIGHT FIXTURE VP ® VAPOR PROOF RECESSED FIXTURE FLOURESCENT LIGHT FIXTURE FLOOD/SECURITY LIGHTS —� UNDER CABINET FIXTURE PHONE JACK © DOUBLE CAT 5e CABLE tV VIDEO OUTLET CV CENTRAL. VAC. HOSE OUTLET Q EXHAUSTFAN O SMOKE DETECTOR OT THERMOSTAT ST SPRINKLER TIMER OINTERCOM kp KEYPAD J MOTION DETECTOR CEILING FAN GARAGE LEVEL ELECTRIC FLAN SCALE: 3/16" = 1'-O" 5 REVISIONS BY DATE Q PERMIT SETS SH 8.29.201E Q STRUCTURAL COOR SH 9.7.2016 y ,r 9 r .s N IN y A .Le i 4 18, 4 o b, No. im 4� ffi g ELECTRIC METER ® ELECTRIC PANEL ❑D DISCONNECT ® 220VOLT RECEPTACLE SINGLE OUTLET DUPLEX OUTLET DUPLEX OUTLET - HALF SWITCHED GF $ G.F.C.I. PROTECTED OUTLET WPGF WEATHER PROOF GFCI OUTLET ® DUPLEX FLOOR OUTLET -fl- WALL SWITCH -&c�-3 3-WAY WALL SWITCH -69-4 4-WAY WALL SWITCH -dcY-D DIMMER WALL SWITCH -FH-PB PUSH BUTTON SWITCH TO LOWER<:� FLOOR SWITCH CF ❑0 ELEVATOR D : CF is D AHU 2 AHU 3 VP _J ELECTRICAL LEGEND WF WALL MOUNTED FIXTURE CF CEILING MOUNTED FIXTURE WJ WALL MOUNTED J-BOX CJ CEILING MOUNTED J-BOX L 4PCL 1 PULL CORD FIXTURE aRECESSED ADJUSTABLE FIXTURE ® RECESSED LIGHT FIXTURE VP ® VAPOR PROOF RECESSED FIXTURE ® FLOURESCENT LIGHT FIXTURE FLOOD/SECURITY LIGHTS UNDER CABINET FIXTURE @ +60" w/ BACKING FOR TV M I � I PHONEJACK © DOUBLE CAT 5e CABLE tv VIDEO OUTLET Cv CENTRAL VAC. HOSE OUTLET O EXHAUSTFAN O SMOKE DETECTOR O THERMOSTAT ST SPRINKLER TIMER O INTERCOM kp KEYPAD 21 MOTION DETECTOR 9 CEILING FAN 2ND FLOOR ELECTRIC PLAN ,SCALE: 21/16" = l'-0" (D IREVISIONS BY DATE Q PERMIT SETS SH 8.29.2016 Q STRUCTURAL COOR SH 9.7.2016 N 0 PA �i t z a� IL U11105 E 2 2 202