HomeMy WebLinkAboutCertification Design Load Compliance�a
R E C E I'.' ^ D idC'°1 14 Z0�6
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: Diamond Sands Lot 1 Single Family Residence - Brodock Residence
Project Address: 79QQ S Ocean Drive (Hutchinson Island); Jensen Beach, Florida 34957 (St. Lucie Qo.)
Permit #: Occupancy Type: R-3 Construction Type: Type Vb
. ` INSTRUCTIONS FOR USE:
9 This certification must be completed, signed, and sealed by the design professional of record.
_ 0 Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following;
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions,
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida building Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one):
X Enclosed
.Partially Enclosed ____Open
3. Risk Category: X 1 II
ill IV
Expnsure Category: B C �X D
4. Design Wind Velocity 160 Vult
^mph X ASD
�LRFD End Zone Width: 5.1 ft
5. Mean Roof Height 30' _
ft Roof Pitch: : 4 12 Parapet: N/A ft
6. Components & Cladding Design Pressures 115ed; (PSF, based on t0sg4t @ 15'MRH, cl?arly label on all plan openings):
Zone 1: 42.0 Zone 2: 73.0
Zone 3: 108.0
Zone 4: 49.7 Zone 5: 61.4 Garage: N/A
7, Design Loads: Floor: 55 PSF
Roof/Dead: 25
PSF Roof/Live: 20 Balcony: 100 PSF
Dock: NSA PSF Deck: 100 PSF Stairs: 60
PSF Fence: N/A PSF Railings: 200�_PSF
8. Were Shear Walls Considered For Structure? Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? X Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
CoLTN;; i-alse,ce�tify that structural elements depicted on these plans provide adequate resistance to the design
fa ceq�goccl '. d:A,� VA
• • .. /G, tt David S. Knight, P.E. 41060
LICE/�rs� . y� �ql Print Name Cert # & Co. Cert Auth.
,•l vl • �' � . �•,• , E
t i Knight McGuire & Associates, Inc, p r a
US9gna ur:, ate, an'd�eal ; $loyal Balm Pointe Suite 401; Vero Seat , F 3296C1
''.`- Nr�011'72016
L1 tiP,ev(s2cl,d7/25/�2p .
\�