Loading...
HomeMy WebLinkAboutCertification Design Load Compliance�a R E C E I'.' ^ D idC'°1 14 Z0�6 Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Diamond Sands Lot 1 Single Family Residence - Brodock Residence Project Address: 79QQ S Ocean Drive (Hutchinson Island); Jensen Beach, Florida 34957 (St. Lucie Qo.) Permit #: Occupancy Type: R-3 Construction Type: Type Vb . ` INSTRUCTIONS FOR USE: 9 This certification must be completed, signed, and sealed by the design professional of record. _ 0 Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following; o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions, DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida building Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed .Partially Enclosed ____Open 3. Risk Category: X 1 II ill IV Expnsure Category: B C �X D 4. Design Wind Velocity 160 Vult ^mph X ASD �LRFD End Zone Width: 5.1 ft 5. Mean Roof Height 30' _ ft Roof Pitch: : 4 12 Parapet: N/A ft 6. Components & Cladding Design Pressures 115ed; (PSF, based on t0sg4t @ 15'MRH, cl?arly label on all plan openings): Zone 1: 42.0 Zone 2: 73.0 Zone 3: 108.0 Zone 4: 49.7 Zone 5: 61.4 Garage: N/A 7, Design Loads: Floor: 55 PSF Roof/Dead: 25 PSF Roof/Live: 20 Balcony: 100 PSF Dock: NSA PSF Deck: 100 PSF Stairs: 60 PSF Fence: N/A PSF Railings: 200�_PSF 8. Were Shear Walls Considered For Structure? Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie CoLTN;; i-alse,ce�tify that structural elements depicted on these plans provide adequate resistance to the design fa ceq�goccl '. d:A,� VA • • .. /G, tt David S. Knight, P.E. 41060 LICE/�rs� . y� �ql Print Name Cert # & Co. Cert Auth. ,•l vl • �' � . �•,• , E t i Knight McGuire & Associates, Inc, p r a US9gna ur:, ate, an'd�eal ; $loyal Balm Pointe Suite 401; Vero Seat , F 3296C1 ''.`- Nr�011'72016 L1 tiP,ev(s2cl,d7/25/�2p . \�