HomeMy WebLinkAboutConstruction Set0 z 0 a a 3 M J Q U N Y U O 0 O Cr m 0 a 3 v 0 a J 0 (N 0 E 0 M O 1 Im FOUNDATION NOTES GENERAL NOTES 1. THE DESIGN AND CONSTRUCTION OF THE STRUCTURE AND/OR STRUCTURAL COMPONENTS DEPICTED ON THIS PLAN ARE FULLY UNDER THE JURISDICTION OF THE FLORIDA BUILDING CODE 2014. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS WITH THE ARCHITECTURAL PLANS PRIOR TO COMMENCEMENT OF CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR COORDINATION OF CHANGES WITH THE ENGINEERING PLANS AND SPECIFICATIONS. 3. CONTRACTOR SHALL COORDINATE SLAB ELEVATION, CHANGES, DEPRESSIONS, THRESHOLDS, PADS, ETC. AND ANY UNKOWN FIELD CONDITIONS. 4. THE CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO FABRICATION AND START OF CONSTRUCTION AND TO PROTECT AND MAINTAIN ALL THE CONSTRUCTION AND ITS CONTENTS. 5. REFER TO THE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT INDICATED. ANY DIMENSIONAL DISCREPANCY FOUND ON THE STRUCTURAL DRAWINGS SHALL BE FURTHER VERIFIED WITH ARCHITECT * ENGINEER. G. FOR MOUNTING AND SECURING MECHANICAL EQUIPMENT, REFER TO THE MANUFACTURE'S INSTRUCTIONS UNLESS INDICATED ELSEWHERE IN THE CONSTRUCTION DOCUMENTS. 7. THE GENERAL CONTRACTOR SHALL AT ALL TIMES MAINTAIN AT THE JOB -SITE, A CURRENT APPROVED SET OF SHOP DRAWINGS. 8. REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR OPENINGS, SLEEVES, ETC. NOT SHOWN ON THE STRUCTURAL DRAWINGS. 9. ALL CONSTRUCTION PERFORMED IN ACCORDANCE WITH THESE PLANS MUST ALSO MEET OR EXCEED ALL APPLICABLE AND CURRENT BUILDING CODE REQUIREMNT5 AND MUST BE PERFORMED IN ACCORDANCE WITH FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION CCCL PERMIT. 10- AT ALL PHA5E5 OF CONSTRUCTION, IT 5HALL BE THE RESPONSIBILITY OF THE GENERAL_ CONTRACTOR TO CONFIRM THAT ALL PROP05ED CONSTRUCTION 15 IN ACCORDANCE WITH THE M05T UP-TO-DATE CON5TRUCTION DRAWINGS A5 APPROVED BY THE ARCHITECT AND ENGINEER OF RECORD. FOUNDATION NOTES I . FOUNDATIONS SHALL BE PREPARED IN FULL CONFORMANCE WITH THE GEOTECHNICAL ENGINEERING REPORT. 2. ALL RECESSES IN CONCRETE SLAB TO BE COORDINATED WITH ARCHITECT FOR DETAILS INCLUDING BUT NOT LIMITED TO: THRESHOLDS, STEPS, RECESSED SHOWER LOCATIONS, FLOORING FINISH MATERIALS, AND DRAIN LOCATIONS, ETC. 3. A VAPOR BARRIER IS TO TO BE PLACED UNDER ALL NILDING FOUNDATION BEAMS AND FLOOR SLABS IN ACCORDANCE WITH ASTM E 1 993-98. TO BE INSTALLED PRIOR TO POURING CONCRETE FOR FOUNDATION. 4. ALL ELECTRICAL CONDUIT, PLUMBING, A/C DUCTS, AND OTHER MECHANICALLY REQUIRED INTEKIOUK COMPONENT LOCATIONS AND INSTALLATION MUST BE COORDINATED WITH THE ARCHTECT PRIOR TO CONSTRUCTION OF THE FOUNDATION. 5. CONTRACTOR SHALL COORDINATE SLAB ELEVATION`a CHANGES AND ANY UNKNOWN FIELD CONDITIONS. G. THE FOLLOWING FREQUENCY OF TESTING SHALL BE REQUIRED BEFORE PLACING CONCRETE FOR FOOTINGS AND SLABS: CONTINUOUS FOOTING/GRADE BEAM SHALL BE TESTED EVERY 40 LINEAL FEET AT BEARING ELEVATION AND ONE FOOT BELOW BEARING. COLUMN FOOTINGS - 25% OF FOOTINGS SHALL BE TESTED AT BEARING AND ONE FOOT BELOW BEARING. BUILDING PAD 511ALL BE TESTED EVERY 1000 SQUARE FEET OF FLOOR AT GRACE AND ONE FOOT BELOW GRADE. IN AREAS OF THE BUILDING PAD WHERE 501L 15 BEING CUT IT 15 THE RESPONSIBILITY OF THE SITE CONTRACTOR TO DEN5IFY THE TOP 12 INCHES OF EXISTING SOIL TO 95% OR MODIFIED PROCTOR AS RECOMMENDED IN THE SOILS REPORT FOR THIS PROJECT PREPARED BY K5M ENGINEERING, INC. DATED NOVEMBER 2009. THESE SOIL TESTS SHALL MEET OR EXCEED 95% MODIFIED PROCTOR (ASTM D 1 557 METHOD A) DEEP FOUNDATION 1. PILES SHALL BE CAST IN PLACE (AUGER) I G" DIA (SEE TYPICAL DETAIL) 2. ALL PILES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE SOILS ENGINEER AND PROVIDE THE FOLLOWING CAPACITIES: all piles @ 20'± below scour - 40 TONS COMPRESSION; 12 TONS TENSION 3. UNLESS OTHERWISE NOTED ON PLANS, CENTER ALL FILES/PILE CAPS UNDER RESPECTIVE COLUMNS. 4. CAST IN PLACE (AUGER) TYPE PILES SHALL CONSIST OF CONCRETE PLACED AFTER BEING DRILLED BY A CONTINUOUS FLIGHT AUGER. TOLERANCE FOR PILES IS 2" IN ANY DIRECTION UNLE55 NOTED OTHERWISE. ALL PILES TO PENETRATE (-) 20.00 NAVD OR AS NOTED. 5HALLOW FOUNDATIONS I . SOIL TO BE STRIPPED, COMPACTED AND TESTED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE SOILS ENGINEER AND PROJECT SPECIFICATIONS. 2. CENTER ALL FOOTINGS UNDER THEIR RESPECTIVE COLUMNS OR WALLS UNLESS OTHERWISE SHOWN ON PLANS. MAXIMUM MISPLACEMENT OR ECCENTRICITY SHALL BE 2". TOLERANCE FOR M15LOCATION OF COLUMN DOWELS OR ANCHOR BOLTS TO BE PER ACI OR AISC STANDARDS. 3. WHERE VERTICAL CONSTRUCTION JOINTS OCCUR IN CONTINUOUS FOOTINGS, PROVIDE A KEYWAY PER THE TYPICAL DETAIL. HORIZONTAL JOINTS IN FOOTINGS WILL NOT BE PERMITTED. 4. CONTRACTOR TO NOTIFY ARCHITECT/ENGINEER IF SOIL CONDITIONS ARE UNCOVERED THAT PREVENT THE REQUIRED SOIL BEARING PRESSURE FROM BEING OBTAINED, 5. COORDINATE PLUMBING LINES WITH FOOTING LOCATIONS FOR INTERFERENCE. INDIVIDUAL FOOTINGS SHOULD BE LOWERED WITH THE PRIOR APPROVAL OF THE STRUCTURAL ENGINEER. CONTINUOUS WALL FOOTINGS SHOULD BE STEPPED AS DETAILED ON THE DRAWINGS. G. EXCAVATING UNDER OR NEAR IN -PLACE FOOTINGS/FOUNDATIONS WHICH DISTURBS THE COMPACTED SOIL BENEATH THE FOOTINGS/FOUNDATIONS WILL NOT BE PERMITTED. 7. REINFORCING SHALL BE SUPPORTED ON PRECAST CONCRETE PADS. DOWELS FOR COLUMNS AND FILLED CELLS SHALL BE SECURED IN PLACE PRIOR TO POURING CONCRETE. USE TEMPLATES FOR SETTING COLUMN DOWELS AND ANCHOR BOLTS. CONCRETE REI N FORMCEMENT I . CONCRETE REINFORCING BARS SHALL BE DEFORMED NEW BILLET STEEL CONFORMING TO ASTM A-G 15, GRADE GO, WITH MINIMUM YIELD STRENGTH = GO,000 psi. 2. REINFORCEMENT FOR CONTINUOUS FOOTINGS SHALL BE CONTINUOUS AND SPLICED WITH A FULL 24 INCH LAP. PROVIDE CORNER BARS 3. ALL CONCRETE MASONAKY CONSTRUCTION SHALL CONFORM WITH ACI 530-88/A5CE 5-88. ALL CONCRETE MASONRY UNITS SHALL COMPLY WITH ASTM C-90 WITH TYPE M OR S MORTAR COMPLYING TO ASTM C-270, MASONRY UNITS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI ON THE NET AREA. 4. ALL SPLICES SHALL BE LAP SPLICES, SHALL BE A MINIMUM OF 48 BAR DIAMETERS, USING LARGER BAR DIAMETER WHEN SPLICING DIFFEKL=_NT SIZE BARS.REINFOKCEMENT TERMINATIONS INTO TIE BEAMS AND FOUNDATIONS OR AS NOTED. 5. REINFOKMCEMNT MAY BE BENT IN SHOP OR FIELD, PROVIDED THAT THE DIAMTERE OF BEND SHALL BE GREATER THAN G BAR DIAMETERS. REINFORCEMENT PARTIALLY EMBEDED IN CONCRETE SHALL NOT BE BENT. G. SECURE REINFOKMCEMNT FROM DISPLACEMENT DURING PLACEMEMNT UTILIZING CHAIRS AND BOLSTERS. WELDED WIRE MESH SHALL CONFORM TO ASTM A- 185. PROVIDE CHAIRS AND BOLSTERS TO INSURE THAT THE MESH IS EMBEDDED I " FROM TOP OF SLAB. 7. STANDARD 90 DEGREE HOOK (STANDARD HOOK) SHALL TERMINATE WITH A 90 DEGREE BEND AND AN EXTENSION FROM BEND AT LEAST 12 BAR DIAMETERS. THIS SHALL BE USED AT ALL VERTICAL REINFORCEMENT TERMINATIONS INTO TIE BEAMS AND FOUNDATIONS OR AS NOTED. 8. MINIMUM CONCRETE COVER SHALL BE: FOOTINGS * PILES 3" BEAMS, SLABS, WALL 2" GROUTED MASONRY 2" 9. ALL PILE VERTICAL REINFORCEMENT SHALL BE SHOP FABRICATED WITH CLEAN 900BENDS INTO TRANSITION CAPS. HOOKS SHALL HAVE A MINIMUM LEG DIMENSION OF 15" AND SHALL BE TURNED ACRO05 PILE INTO CAP CENTER (MAINTAIN A MINIMUM 3" CONCRETE COVER). 10. ALL BEAM STEEL SPLICES SHALL OCCUR, AT MID5PAN FOR TOP STEEL AND OVER COLUMNS FOR BOTTOM STEEL. CONCRETE NOTES I . ALL CONCRETE DESIGN AND PLACEMEW SHALL BE IN STRICT ACCORDANCE WITH THE ACI "BUILDING CODE REQUIREMENTS FOR STRUCTURAL_ CONCRETE," ACI 3 18-95. 2. CONTACT ENGINEER 48 HOURS PRIOR TO POURING CONCRETE SO ARRANGEMENTS CAN BE MADE TO HAVE AN ENGINEER OR INSPECTOR PRESENT DURING THE POUR. 3. PROVIDE (4) TEST CYLINDERS FOR EACH 50 C.Y. OF CONCRETE PLACED OR FRACTION THEREOF. 4. STRUCTURAL CONCRETE SHALL CONFORM TO ACI 301 SPECIFICATIONS AND SHALL DEVELOP THE FOLLOWING MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS: SPREAD AND WALL FOOTINGS 3000 PSI COLUMNS AND WALLS 3000 PSI BEAMS AND SLABS 3000 PSI USE REGULAR WEIGHT CONCRETE. 5. STRUCTURAL CONCRETE SHALL CONFORM TO ACI 301 AND HAVE THE FOLLOWING SLUMPS AGGREGATE REQUIREMENTS: LOCATION SLUMP MAX. AGGREGATE FOOTINGS 411± I" ASTM #57 COLUMNS 5"± 1 " ASTM #57 BEAMS AND SLABS 511± I" ASTM #57 FILLED CELLS 811± I" ASTM #8 PEAROCK TIE BM5 * TIE COL5 5"± 1 " ASTM #8 PEAKOCK PILES 8"± I " ASTM #8 PEAKOCK THE USE OF JITTERBUGS TO CONSOLIDATE CONCRETE WILL NOT BE PERMITTED, G. ALL PUMPED CONCRETE WITH #57 AGGREGATE IS TO CONTAIN A HIGH RANGE WATER REDUCING AGENT. MINIMUM SIZE OF DISCHARGE TO BE 4" I.D. 7. A 2" I.D. DISCHARGE MAY BE USED WITH #8 AGGREGATE. USE PLASTICIZER ADMIXTURE IF NECESSARY TO INCREASE SLUMPS BEYOND THAT NOTED ABOVE. 8. CHAMFER ALL EDGES OF EXPOSED CONCRETE 3/4" UNLESS NOTED OTHERWISE. 9. ALL SLABS ON GRADE SHALL BE FIBER RFINFORCED CONCRETE, UNLESS NOTED OTHERWISE. WELDED WIRE FABRIC SHALL CONFORM TO ASTM-A 185. 10. SLEEVE ALL PENETRATIONS THROUGH BEAMS AND SLABS INDIVIDUALLY. CORE DRILLING WILL NOT BE PERMITTED. SUBMIT LOCATION AND 512L OF SLEEVES THROUGH BEAMS TO ENGINEER FOR REVIEW PRIOR TO CASTING CONCRETE. 1 1. NO REINFORCING BARS SHALL BE CUT TO ACCOMMODATE THE INSTALLATION OF ANCHORS, EMBEDS OR OTHER ITEMS. 12. AT CHANGES IN DIRECTION OF CONCRETE WALLS, BEAMS * STRIP FOOTINGS, PROVIDE CORNER BARS OF SAME SIZE AND QUANTITY UNLESS NOTED OTHERWISE AS HORIZONTAL STEEL, REFER TO TYPICAL DETAIL. 13. ALL EMBEDDED ITEMS SHALL BE SECURELY TIED IN PLACE PRIOR TO CONCRETE PLACEMENT. 14. WEDGE BOLTS SHALL BE ITW RAMSET/REDHEAD BOLTS OR APPROVED EQUIVALENT INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. DO NOT CUT EXISTING REINFORCING TO I N5TALL. 15. HEADED STUD ANCHORS SHALL BE ASTM A 106, GRADE 5, 1010 THROUGH 1020 AS MANUFACTURED BY NELSON STUD OK APPROVED EQUIVALENT. STUD WELDING SHALL CONFORM TO AWS D 1. 1 "STRUCTURAL WELDING CODE." I G. FOOTING SIZES SHOWN ARE FOR FOOTINGS CONSTRUCTED WITH SIDE FORMS. IF SOIL MATERIAL CAN HOLD A VERTICAL SHAPE, IT CAN BE USED AS AN EARTH FORM. ALL SLOUGHED MATERIAL SHALL BE REMOVED FROM EXCAVATION BEFORE AND DURING PLACEMENT OF CONCRETE. 17. PLACEMENT OF CONDUIT AND PIPES IN CONCRETE SHALL CONFORM TO ACI 3 16, SECTION G.3. THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. m P2 P3 CONS RUCTION S P4 P5 PG P7 Ive- a s P25 P2G P27 P26 P29 P30 P3 I PILING OVERVIEW SCALE: 3/ 1 G" = I '-011 CODE * DESIGN CRITERIA I. ALL STRUCTURAL PLANS SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE AND FLOKIDA BUILDING CODE L,ESIDENTIAL 2014. 2. BUILDING CLASSIFICATION ENCLOSED 3. 4. DESIGN WIND SPEED I GOmph Vult IMPORTANCE FACTOR 1.0 5. EXPOSURE CLASSIFICATION D G. 51E5MIC ZONE 0 7. MEAN BUILDING HEIGHT 27. 17' 8 . ALLOWABLE SOIL BEARING PRESSURE 2,500 P5F ASSUMED. VERIFY WITH GEOTECHNICAL ENGINEER PRIOR TO CONSTRUCTION ASSUMPTIONS: A. THE BUILDING IS "ENCLOSED" AS DEFINED IN "FLORIDA BUILDING CODE 2014 B. WIND VELOCITY PRESSURES AND COEFFICIENTS USED ARE FOR MAIN WIND FORCE RESISTING SYSTEM; ALLOWABLE STRESS DESIGN, Kd = 0.85. C. ALL PRE -MANUFACTURED COMPONENTS, I.E. WINDOWS, DOORS, JAMBS, TRUSSES ETC. SHALL BE VERIFIED BY MANUFACTURER. TO BE CAPABLE OF SUSTAINING DESIGN WIND FORCES. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS. D. ALL COMPONENTS AND CLADDING SUBJECT TO WIND LOADINGS: I.E. ROOF TILES, SOFFITS, ETC. SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS FOR ADEQUATELY RESISTING OR TRANSFERRING WIND LOADS TO THE MAIN WIND FORCE RESISTING SYSTEM. E. OWNER OR CONTRACTOR SHALL OBTAIN NECESSARY INSTALLATION SPECIFICATIONS AND INSPECTIONS REQUIRED TO COMPLY WITH MANUFACTURERS RECCOMMENDATION5 FOR INSTALLATION OF COMPONENTS AND CLADDING FOR HIGH WIND VELOCITY AREAS. REFER TO SHEET 5-2 FOR PILING SCHEDULE MA50NKY NOTES I . MASONRY CONSTRUCTION SHALL CONFORM TO ACI 'BUILDING CODE EQUIREMENTS FOR MASONRY STRUCTURES" (ACl/ASCE 530-88) AND SPECIFICATIONS FOR MASONRY STRUCTURES" (ACl/ASCE 530. 1-88) EXCEPT AS AMENDED BELOW, 2. STRUCTURE HAS BEEN DESIGNED AS A BEARING WALL STRUCTURE. ALL MASONRY UNITS SHALL BE LAID PRIOR TO CONCRETE PLACEMENT OF COLUMNS, BEAMS AND SLABS FOR THE SAME STORY. 3. USE TYPE "M" MORTAR WITH MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI FOR ABOVE GRADE APPLICATIONS AND TYPE "S" MORTAR WITH A MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI FOR BELOW GRADE APPLICATIONS. 4. MASONRY UNITS SHALL CONFORM TO ASTM C90 WITH A MINIMUM COMPRESSIVE STRENGTH OF 2600 PSI ON NET SECTION, TO PROVIDE NET AREA COMPRESSIVE STRENGTH OF MASONRY (Fm') OF 2000 PSI. 5. PROVIDE FILLED CELLS AS SHOWN ON PLANS. IN ADDITION, PROVIDE FILLED CELLS: A. AT ANCHORAGE OF CONNECTIONS OR BEARING OF BEAMS AND GIRDER TRUSSES. B. AT ALL CORNERS AND INTERSECTIONS C. (1) CELL ADJACENT TO OPENINGS FOR WALL SPANS LE55THAN 10'. (2) CELLS ADJACENT TO OPENINGS FOR WALL SPANS GREATER THAN 10' D. AS SHOWN ON ARCHITECTURAL PLANS E. MAXIMUM 48" O.C. (UNLESS NOTED OTHERWISE) G. PROVIDE FULL MORTAR BEDDING AROUND ALL FILLED CELLS WITH VERTICAL REINFORCING. 7. REINFORCING FOR FILLED CELLS SHALL CONFORM TO ASTM AG 15, GRADE GO, LAPPED 48 BAR DIAMETERS. 8. ALL FILLED CELLS AND COLUMNS SHALL BE POURED AT LEAST TWO (2) HOURS PRIOR TO POURING BEAMS AND LINTELS. 9. REINFORCE WALL WITH LADDER TYPE REINFORCEMENT ("DUR-O-WALL" OR EQUAL) IN BED JOINTS AT I G" O.C. MEASURED VERTICALLY. LAP SPLICE ALL HORIZONTAL WALL REINFORCING G". PROVIDE PREFABRICATED "TEE" OR CORNER SECTIONS AT ALL INTERSECTING WALLS. TP) 10. REFER TO TYPICAL WALL SECTIONS FOR MAXIMUM CONSTRUCTION HEIGHT OF MASONRY WALLS. PROVIDE CLEAN -OUT HOLES AT BASE OF FILLED CELL WHEN THE CONCRETE POUR EXCEEDS 5 FEET IN HEIGHT. l V1 U 1� Gzr 7A O w a � � z `rV W M�wz� T�U�aw� V ►--i ►� c H Z a � O � w W O U � �+ cat O (t w CCj 7 U � �0 � OCCU � •nr-I 16-0391 S-1 PI F2 7'-101, 8' CRITICAL BEAR 35 kips CON P32 F33 P39 0 r COMBO PILING f TRANSITION CAP refer to sheet 5-3 13' 45 kips COMPRESSION P3 P4 -6" 8 6t —7— TYPICAL PILING @GARAGE - on SHEARWALL FOOTING 25 kips TYPICAL LOADING TYPICAL PILING @ GARAGE (NON SLOPED CAP) 1 7-0" TYPICAL PILING @ GARAGE -- w/ PERIMETER CURB ;AL BEARING PILING 15 COMPRESSION P9 LOAD 81- 10" F(5 1 2 TYPICAL PILING @ F[5hIfAKWALL FOOTING3 p EQU CRITICAL BEARING PILING I 1 ER IT 'rR ENT F-4 G 27 kips COMPRESSION ' F34 LOAD i........................................._ ....... ...... ....... ....... ...... ..................................................... F35 COMBO PILING EXTENDED TYPICAL PILING AT SLAB ELEVATION TRANSITION CAP CHANGE - ASSOCIATED CAP MAY BE refer to sheet 5-3 for dimensions I 4 POURED LEVEL AT THIS LOCATION FP47 P17 �� F1 5 P18 — —� -- - TYPICAL PILING EXTENDED 7' 2„— 7'_4" 6'-8" TRANSITION CAP ch refer to sheet 5-3 for dimensions CRITICAL BEARING PILING 35 kips COMPRESSION F22LOAD F1 G o r TYPICAL PILING @ I 5HEARWALL FOOTING .......... ... ....... ....... ...... ....... ....... .... L L i Sk 8'-8" 1105 TYPICAL PILING EXTENDED TRANSITION CAP P 19 P 2 1 p 2 1 F23 refer to sheet 5-3 for dimensions TYPICAL PILING @ ELEVATOR PIT - REFER CRITICAL BEARING PILING TO DETAIL SHEET 5-9 36 kips COMPRESSION 6" LOAD P40 fTYPICAL PILING TRANSITION CAP F4 I TYPICAL PILING AT SLAB ELEVATION CHANGE - ASSOCIATED CAP MAY BE POURED LEVEL AT THIS LOCATION TYPICAL PILING 4- EXTENDED TRANSITION CAP refer to sheet 5-3 for dimensions � 5'-2" 18'-4" 14'-7" If : -1 P42 O o TYPICAL PILING @ SHEARWALL FOOTING 30 kips MAX. LOADING 91 P2F276 5P2P28 AUGER-CAST PILE LAYOUT SCALE: 114" = 1 '-0" THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT F'RIOR TO CONSTRUCTION. 19" P45 6'- 10" r 7' 13" F29 I 13" P30 rel P31 ING @ PATIO TH POOL DESIGNER -ON FLI CTS NG @ PATIO -H POOL DESIGNER ;ON FLI CTS CONSTRUCTIONS T 8"x I G" POURED -IN -PLACE CONCRETE COLUMN w/ (4,' #5'5 vert. * #2 STIRRUPS 4' O.C. AT BASE * 1 2" O.C. ELSEWHERE AS SHOWN see column detail= TRANSITION CAF REFER TO TRANSITION CAF DETAIL (sheet 5-3) FOR REINF, CLEAN OUT G" BELOW TOP OF PILE PRIOR TO CAP CONSTRUCTION #3 STIRRUPS SPACED 3" O.C, @ TOP OF PILE THEN 10" O.G. FOR REMAINDER AS SHOWN I G" dla. AUGER CAST PILE w/ (G) #G BARS only (3) bars shown PILE SHALL BE DRILLED w/ f CONTINUOUS FLIGHT AUGEF AND CAST w/ 5,000 PSI GROU1 WIRE TIE (G) #3 BARS TAPERED TO POINT * TIED TO PILE CAGE AS SHOWN >K ALL PILE REINF 'ARD5 CENTER OF \151TION CAP E TRAN5. CAP EE _`)CHEDULE 3EDMENT CAPACITY IS RELATIVE TO PILE DEPTH >W THE SCOUR LINE. REFER TO DEEP �DATION NOTES FOR DETAILS. BOTTC_.`)M OF PILE CAGE EL.=5EE 5CHEDULE PILE/CAP/COLUMN DETA iL SCALE: NOT TO SCALE PILING 5CN EDU LE DESIGNATION TYPE TOP OF PILE PILE DEPTH PILE length CAP deation P I -P4 I G" AUGER -CAST 5.42 navd I -24.58 navd 30.00 i 7. 17 P5-P 10 _ _ 1 G" AUGER -CAST _...................._................................................ 5.58 navd -24.42 ........... navd ................................................ 30.00' 7.33' P I 1-F30 I G" AUGER -CAST 5.92 navd I t -24.08 t navd 30.00' I 7.G7' P3 I ......._ OMITTED ......................................................._...............................................,......................_ _......................,........................._..................... t i P32-P33 1 G" AUGER -CAST 5.42 navd ................................ -24.58 ..._..................1................................._...,..........-__............:................ navd I 30.00 ................................ ............................ 7. 1 7' P34-P35 ....................................................................................................................................................................... I G" AUGER -CAST .......:............................................................_.............i..........._...........................................................,................ 5.58 navd -24.42 navd 30.00' E `..............................................., t .. .................. �/7.33' / . . P3G-P43 I G" AUGER -CAST 5.92 navd t E -24.08 navd `..........,.,..................................... 30.00' t 7.67' ....--- ....------------ ........--._-._.-----_.._......................_..__,._.__....._........__..........._......._._..........__.__.._................._._._..........._....._,................_.,,,_.___..L----------.__---------...................,._-----_..._._..,.__'___........_.:__....._.,,._...__._.........._._.._._...,...............i_.._._--._____. ..... _._....._...----- - - P44 P 4G ......................................................................................................................................................................:.......................................................................... I G AUGER -CAST 5.58 navd -24.42 .................................................................................................................................... navd 1 30.00 7.3 3 P47 I G" AUGER -CAST 5.92 navd -24.06 navd I 30.00 I 7 G7 P48-P54 I G" AUGER -CAST 5.58 navd E -24.42 navd 30.00' I I 7.33' INSTALLATION NOTE: TOP OE PILE STEEL SHALL NOT EXCEED 3" (0.25 feet) BELOW THE CAP ELEVATION U ® � 7O 4� U � J 7 oAAVV-^I�/111; r-I O W R0JEC TU. 16-039 Q,HEE S-2 CONSTRUCTIONS T 41 N N N MONOLITHIC FOOTER (typ.) refer to details — ALL STEEL DISCONTINUOUS AT TRANSITION CAPS ,_2" 2 1 THICKENED E E - _...under—patio nt to N I (t . pa . . . . . . . ... ... (at under t' y� ►: slab perimeter) i 0 I THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIC NED AND SEALED BY THE ENGINEER. J ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONC)ITIONS AND CONTRACT DOCUMENTS. E CONTRACTOR SHALL COORDINATE ALL DETAILS AND M ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. 4" thick FRANGIBLE SLAB (A/C equipment pad — refer to architecturals for locations) 71- ^ II TRANSITION CAP LAYOUT fRANG115LE FOOTINGS �SLABS SCALE: 114" == 1 '-0" refer to EXTERIOR STEPS FOl)NDAfiION PLAN sheet S-10 a 4" THICK CONCRETE SLAB (MINIMUM 3000 PSI @ 28 DAYS) MESH REINFORCED — SAW CUT AS SHOWN 60. OVER 6 MIL. VISQUEEN VAPOR BARRIER ✓ER CLEAN COMPACTED TERMITE TREATED FILL (COMPACTED TO 95% DENSITY) typical for all GROUND FLOOR slabs SAW —CUT FRANGIBLE 51-At5 DETAIL SCALE: not to scale ..... CONTINUOUS POOTER @ EXTERIOR PERIMETER / 2 #5' t TYP #3 STIRRUPS MFR'd w/ 9%4" INSIDE DIA. (G) #GO IN AUGER CAST PILE exterior edge r interior edge �I G" AUGER CAST PILE W ( ) 5 con ( ,) PILE CAP see detail TYPICAL PILE @ TRANSITION CAP (w/ a@acenL contlnUOUS footing) #3 STIRRUPS MFK'd #3 STIRRUPS MPR'd exterior edge of grade beam w/ 9%4" INSIDE DIA. w/ 9%4' INSIDE DIA. @@ (G) #GO IN AUGER CAST PILE I G" AUGER CAST PILE interior edge of grade beam I G" AUGER CAST PILE TYPICAL PILE @ GRADE BEAM TYPICAL #G IN AUGER CAST PILE top of Ile bottom of transltlon cap 7CAST GERPILE 4. -4. I G TYPICAL PILE PROIFILE exterior edge of tirade beam interior edge of grade beam - (G) #GO IN AUGER CAST PILE TYPICAL PILE @ GLADE BEAM (CORNER) PILE REINfORCEMENT DETAILS SCALE: NOT TO SCALE (7) #Gx 16" @ 9" O.C. AS 5MOWN (3) #3 STIRRUPS @ 9" O.C. #Gx 18" EACH SIDE AS SHOWN PROVIDE A MINIMUM 3" CONCRETE COVER FOR ALL kEINFORCING STEEL TRANSITION CAP DETAILS SCALE: NOT TO SCALE CCU U � o • • ^+ • CCU V� � CCU TT® "V U O U 0 cn O � � • rn-I I� PROJEC T ?C. 16-039 S-3 1 5-8 CONSTRUCTIONS T x2 PRE f NGI NEERffD WOOD I ; i C- { cv ` "U -00R TRJS5ffS G124n J.0 > Jn f rl - SLOPE 1 - reer td 5ho d awln _ (2) 2x 10 fs. 1`. LEDGER CA CTB-1 C- I 101-0° THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. I st FLOOR FRAMING PLAN CONCRETE COLUMN LAYOUT c LE 1/411 = .o FI RST FLOOR CONCRETE TI E BEAM SCH EDU LE MARK PLAN 51ZE REINFORCEMENT TOP of BEAM REMARKS D W TOP M. BOT. 5TIRRUP5 CTB- I 2411 8" (2) #5 n/a (2) #5 #3 @ 1 2" O.C. +0'-0" TYPICAL 15t FLOOR BEAM exterior CT15-2 24" 1 2" (3) #5 n/a (3) #5 #3 @ 1 2" O.C. +0'-O" 1 2" BEAM - FLOOR SUPPORTING CTB-3 2411 1 G11 (3) #5 n/a (3) #5 #3 @ 1211 O.C. +0'-011 INTERIOR I G" BEAM @ GARAGE CTB-4 24" 1 2" (3) #5 n/a (3) #5 #3 @ 1 2" O.C. sloped BOTTOM @ -2'-0" B.F.F. CTB-5 24" 1 2" (2) #5 n/a (2) #5 #3 @ 1 2" O.C. +0'-0" 1 2" BEAM - EXTERIOR WALL BEARING CTB-5a 3G" 1 1 2" (2) #5 n/a (2) #5 #3 @ 1 2" O.C. +0'-0" DEPTH TO COINCIDE w/ WINDOW El. CTB-G 20" 8" (2) #5 n/a (2) #5 #3 @ 1 2" O.C. sloped BOTTOM @ -2'-0" B.F.F. CTB-7 20" 8" (2) #5 n/a (2) #51 #3 @ 1 2" O.C. varies TYPICAL PATIO SLAB BEAM CTB-8 2311 1 81' (2) #5 n/a (2) #5 #3 @ 1 2" O.C. -0'-2" TYPICAL 15t FLOOR BEAM Interior 7r—W—� CTB 2 C"TE3-5 �W "I f i CTE3-2 _Je _ W , CTE3-G G11 PATIO 5LA5 REINFORCEMENT 15 IDENTICAL TO CTB- I CTE3-1.- CTE3-'-/" �W� o i CTE3-4 I I CTE3-8 SPECIALLY LOADED BEAM W (3) #5's cont. TOP STEEL 4-4-41 (3) #5x72" left side TOP 5TEEL (4) #3 5TIRRUP5 @ G" O.C. o (typical at beam ends) } #3'5 @ 1 2" O.C. elsewhere k i !. • .••:t (3) #55 cont. BOTTOM STEEL CTt5--2a CONCRETE COLUMN SCHEDULE MARK PLAN 51ZE REINFORCEMENT REMARKS B h VERTICAL TIES C 1 811 1 G" (4) #5 #3 @ 1 2" O.C. TYPICAL FORM -POURED COLUMN C2 811 1 G" (G) #5 #3 @ 1 2" O.C. TYPICAL CORNER FORM -POURED COLUMN C3 12 I 0 (G) #5 #3 @ 1 2" O.C. TYPICAL FORM -POURED COLUMN @ I G11 BEAM C4 1 211 1 211 (4) #5 N/A 1 2" 561, PILASTER BLOCK COLUMN - see note below C5 811 301 (8) #5 (2) #3 @ 1211 O.C. BOUCLE "C- I " COLUMN CG 2411 30' (10) #5 (2) #3 @ 1 2" O.C. ECCENTRIC CORNER COLUMN C7 2411 3G" (10) #5 (2) #3 @ 1 2" O.C. DOUBLE 11C-2" CORNER COLUMN C8 1 211 12" (4) #5 #3 @ 1 2" O.C. 1 2" sc[. FORM -POURED COLUMN 5EE PLAN FOR ORIENTATION C-7 51MILAR rn C - (f) C-8 MAY BE U5ED IN PLACE OF C-4 I PRO„ EC T NO, 16-039 S IFE I S-4 E 0 0 0 Z CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. 2nd FLOOR FRAMING PLAN LOWER RO- -OfOA:MING FLAN. scare. va.= P-o' CONSTRUCTIONS T LOWER ROOF/SECOND FLOOR CONNECTOR SPECIFICATION CHART CONNECTOR MARK REACTIONS CONNECTOR ALLOWABLE FASTENERS REQUIRED per TRUSS MANUFACTURER LOAD MFR's SPECIFICATIONS & DESCRIPTION LABEL(s) UPLIFT 1 NUMBER GRAVITY 1 GRAVITY 1 UPLIFT t TYPE QUANTITY A ALL WOOD TO WOOD CONNECTIONS, UNLESS 1950 MTS12 SIMPSON t 1000 10d x Q2" NAILS 14 <xxxx NOTED BELOW. max. B ALL WOOD TO CONC. CONNECTIONS, UNLESS t 1800 HETA20 SIMPSON 11810 10d x 1)/2" NAILS 9 xxX <XNOTED BELOW. max. SINGLE PLY GIRDER C TRUSS TO CONCRETE t 2400 DETAL20 SIMPSON t 2480 10d x Q2" NAILS 18 (truss) <xxxx LINTEL/BOND BEAM Max. WOOD TRUSS TO (2) D ALL TRUSS LEDGER t 458 max. LUS26 SIMPSON t 1165 10d NAILS 4 (truss) <xXXx 2x8 LEDGER (bucket) U. N. 0. 1918 max. 11070 4 (ledger) GIRDER TRUSS TO (2) E D7 t 838 max. LUS28 SIMPSON 1165 10d NAILS 4 (truss) 2x8 LEDGER (bucket) 11345 max. 11360 6 (ledger) <xxxx Jz 1= <xxxx G <xxxx SECOND FLOOR CONCRETE TIE BEAM SCMEDULE MARK PLAN 51ZE REINFORCEMENT TOP of BEAM REMARKS D W TOP M. BOT. STIRRUPS CTB-9 24" 8" (2) #5 n/a (2) #5 #3 @ 1 2" O.C. + 1 3'-0'' 8" BEAM - 2nd FLOOR WALL CTB-1 0 24" 1211 (3) #5 n/a (3) #5 #3 @ 1 2" O.C. + 1 1'-4'' 1 2" PATIO ROOF BEARING CTB- I 1 20" 1 2" (3) #G n/a (3) #G #3 @ 1 2" O.C. + 1 3'-0" 1 2" BEAM - COFFERED CLG BELOW CTB- 1 2 24" 1 2" (3) #5 n/a (3) #5 #3 @ 1 2" O.C. + 1 2'-G" BALCONY SLAB 5UPPORTING CTB- 1 3 1 4" 1 G" (3) #G n/a (3) #G #3 @ 1 2" O.C. + 1 1'-4" see notes on detail below CTB- 1 4 24" 1 2" (2) #5 1 (2) #5 #3 @ 1 2" O.C. + 1 3'-0" 1 2" BEAM - 21 FLOOR SLAB CT13-1 5 24" 8" (2) #5 n/a (2) #5 #3 @ 1 2" O.C. + 13'-0" 21 FLOOR CANTILEVERED AREA CTB- 1 5a 1 9" 8" (2) #5 n/a (2) #5 #3 @ 1 2" O.C. + 1 2'-1 1 " with (2) #5x3G" TOP STEEL at ends CTB- I G 23" 8" (2) #5 n/a (2) #5 #3 @ 1 2" O.C. + 1 2'-1 1 " TYPICAL INTERIOR BEAM 3) #05 Cont. TOP x3G" TOP at ends #5x72" BOTTOM (center) "5 cont. BOTTOM THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. CTE3--9 CTE5-13 N�e CTE3-14 C715-11 CTE3-1 5 ( ,'TE3-. I G 51MILAR CT13-12 CT13- LOWER ROOF CONCRETE LINTEL SCHEDULE APPLIED LOADS ON ALL PRECAST LINTELS HAVE BEEN REVIEWED TO INSURE THEY ARE WITHIN ALLOWABLE LIMITS. LINTEL NO. LENGTH SAFE GRAVITY LOAD APPLIED GRAVITY LOAD SAFE UPLIFT LOAD APPLIED UPLIFT LOAD COMPOSITE BEAM REMARKS L� 3'-10" 10394 240 5740 175 8F28-1 B/1 T 0 6'-2" 10394 495 3498 130 8F28-1 B/1 T L3 13'-6" 2127 265 1052 210 8F28-1 B/1 T L4 4'-6" 10294 210 5077 150 81`28-1 B/1 T L5 6'-2" 10394 550 3498 260 8F28-1 B/1 T L6 3'-6" 10394 300 6613 100 81`28-1 B/1 T L� 3'-6" 10394 240 6613 175 8F28-1 B/1 T L8 6'-6" 10394 180 3498 100 8F28-1 B/1 T L9 3'-6" 10394 NL 6613 NL 8F28-1 B/1 T SCHEDULE TO BE FILLED IN BY ENGINEER LINTEL DEPTHS MAY BE INCREASED, BUT NOT REDUCED NOTE: R=RECESS NOTE: ALL GABLES & JACKS = <250PLF NOTE: USE CASTCRETE F=FILLED w/ GROUT-- . - QUANITY OF #5 U=UNFILLED Q 1 j REBAR AT TOP NOMINAL WIDTH,,,,,,,,,,,,,,OF I ��' 1 B/l T ;_ QUANITY OF #5 REBAR AT NOMINAL HEIGHT ...,,_„_„% -- ------ ---"- BOTTOM OF LINTEL CAVITY rJ rl. v o Z Zw �< x d� UaW,G OA��E >W� �iov E � ^r E Wz c V � E t .. 5z, E �U00z � Z o a x blJ O� � o O O 7� N U � O c .0 • r� r Vl C Ufa � c � PPojr r No. 16-039 S-5 E 0 M O) 04 0 Z 0 CL a a 3 M O Q 0 U Y U O a O m m M 0 0 U .3 0 a a 0 0 E 0 C, to UPPER ROOF fRAMING PLAN SCALE: 114" = I '-0" THESE PLANS ARE NOT FOR CONSTRUCTION UNLE �S STAMPED "Construction Set", DATED, SIGNED AND SEALED by THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WI1I-1 ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTR/\CT DOCUMENTS. CONSTRUCTIONS T UPPER ROOF CONNECTOR SPECIFICATION CHART CONNECTOR MARK TRUSS REACTIONS CONNECTOR ALLOWABLE FASTENERS REQUIRED per & DESCRIPTION LABEL(s) UPLIFT 1 NUMBER M MANUFACTURER LOAD MFR's SPECIFICATIONS TYPE QUANTITY GRAVITY 1 GRAVITY ! UPLIFT t A ALL WOOD TO WOOD CONNECTIONS, UNLESS t 950 MTS12 SIMPSON t 1000 10d x 1Y2" NAILS 14 `xxxx NOTED BELOW. max. ALL WOOD TO CONC. D CONNECTIONS, UNLESS HJ7A, t 1684 HETA20 SIMPSON t 1810 10d x 1Y2" NAILS 9 <xxxx NOTED BELOW. A7, A8, max. G7, et. al. C SINGLE PLY GIRDER A8 TRUSS TO CONCRETE t 2409 DETAL20 SIMPSON t 2480 10d x 1Y2" NAILS 18 (truss) `xxxx LINTEL/BOND BEAM max. 2+ PLY GIRDER TRUSS D G6 TO CONCRETE t 23. (2) HETA20 SIMPSON t 2700 16d NAILS 12 (truss) `xxxx LINTEL/BOND BEAM max. E GIRDER TRUSS TO CONCRETE BEAM A8A t 2985 MGT SIMPSON t 3965 10d NAILS 22 (truss) � xxxx 5/8" ATR in EPDXY 1 (beam) 1= `xxxx G `xxxx Ir (2) #G Cont. TOP BOTTOM w/ #3 STIRRUPS @ 12" O.C. 7 � SET TRUSSES TO 51MP5ON VTCR @ lin. 2 per tru55) ALL MASONRY WALL TOP Of REAM (upper roof bearing) @ +23'-0" A. F. E unless noted otherw15e ALL UPPER ROOF SEARING Sr iALL DE ON 8"x24" (3-COURSE) E )ND REAM, UNLESS NOTED OTHER\NISE refer to 5ectlon5 and detail-) UPPER ROOF CONCRETE LINTEL SCHEDULE APPLIED LOADS ON ALL PRECAST LINTELS HAVE BEEN REVIEWED TO INSURE THEY ARE WITHIN ALLOWABLE LIMITS. LINTEL NO. LENGTH SAFE GRAVITY LOAD APPLIED GRAVITY LOAD SAFE UPLIFT LOAD APPLIED UPLIFT LOAD COMPOSITE BEAM REMARKS L� 10'-10" 2423 765 1272 850 185 650 150 NL 600 8F24-1 B/1 T L2 9'-7" 2781 290 1458 8F24-1 B/1 T L3 4'-6" 8672 1320 4292 81`24-1 B/1 T L4 4'-6" 8672 220 4292 8F24-1 B/1 T L5 11'-4" 2423 NL 1272 8F24-1 B/1 T Ls 4'-0" 8974 1175 4853 8F24-1 B/1 T L� 3'-6" 10394 220 5591 150 8F24-1 B/1 T L8 L9 SCHEDULE TO BE FILLED IN B1 ENGIN-ER LINTEL DEPTHS MAY BE INCREASED, 1'UT NOT REDUCED NOTE: R=RECESS F=FILLED w/ GROUT a„ ............................ QUANITY OF #5 NOTE: ALL GABLES & U=UNFILLED '`` REBAR AT TOP JACKS == <250PLF NOMINAL WIDTH ....... gF 16— 1 BA T NOTE: USE CASTCRETE NOMINAL HEIGHT • --' QUANITY OF #5 REBAR AT ` BOTTOM OF LINTEL CAVITY )ATSTOP R Q'D W% 1-1 /2" CLEAR ._ i- C.M.U. _ GROUT— 7.. w < = -) _ _I �-- Q U z BOTTOM REINFORCING PROVIDED IN LINTEL 0 0 o� z i� #5 REBAR AT BOTTOM C° `n (TYP. VARIES) 7-5/8 ACTUAL 8" NDMINAL WIDTH OF LINTEL CAVITY PRECAc>T LINTEL NOTES 1. PROVIDE FULL MORTOR BED AND HEAD JOINTS. 2. SHORE FILLED LINTELS AS REQUIRED. 3. INSTALLATION OF ALL LINTELS MUST COMPLY WITH THE ARCHITECTURAL and/or STRUCTURAL DOCUMENTS. 4. U-LINTELS ARE MANUFACTURED WITH 5 1 /2" LONG NOTCHES AT THE ENDS TO ACCOMODATE VERTICAL CELL REINFORCING AND GROUTING. 5. REFERENCE THE CAST-CRETE LOAD DEFLECTION GRAPH ROCHURE FOR LINTEL DEFLECTION INFORMATION. 6. BOTTOM FIELD ADDED REBAR TO BE LOCATED AT THE BOTTOM OF THE LINTEL CAVITY. 7. 7�32" DIAMETER WIRE STIRRUPS ARE WELDED TO THE BOTTOM STEEL F R MECHANICAL ANCHORAGE 8. CAST -IN -PLACE CONCRETE MAY BE PROVIDED IN COMPOSITE LINTEL IN LIEU OF CONCRETE MASONRY UNITS. 9. SAFE LOAD RATING BASED ON RATIONAL DESIGN ANALYSIS PER ACI 318 AND ACI 530. 10. PRODUCT APPROVALS: MIAMI-DADE COUNTY FLORIDA NOS. 03-0606.05 & 03-0605.04. FLORIDA CERTIrICATE OF PRODUCT APPROVAL NUMBER FL158. 11. THE EXTERIOR SURFACE OF LINTELS INSTALLED IN EXTERIOR CONCRETE MASONRY WALLS SHALL HAVE A COATING OF STUCCO APPLIED IN ACCORDANCE WITH ASTM C-296 OR OTHER APPROVED COATING.. 12. ALL RACEWAYS AND PIPES PLACED IN OR THROUGH ANY CONCRETE SLAB SHALL BE SPACED A MINIMUM OF THREE DIAMETERS OF THE LARGEST CONDUIT OR PIPE FROM ANY OTHER SERVICE. ADDIied ve tical load + A lied horizontal load Safe ver cal load afe horizontal load 51.0 13. ADDITIONDESIGNER Eft LATERAL LOAD CAPACITY CAN BE OBTAINED BY THE Y PROVIDING ADDITIONAL REINFORCED CONCRETE MASONRY ,ABOVE THE LINTEL. SEE DETAIL AT RIGHT. c r� C c_ 0 2 r= ice_ rr _ C; o (j U, L� o Vl w M bUD E M W J' en �U w o �vi�wo dx�min w �wz`� V �y W ZO � � U i�Vow � 00 a w � l� U 0 M � � O U 0 � � 0 0c , lM�1 •� PPOJFC. T NO. 16-039 HEFT S-6 CONSTRUCTION SET 11 2x4 P.T. CONT. LEDGER w/ 4'x3" T.C. @ 24" O.C. SIMPSON H2.5A at each TRUSS TAIL to NAILI�,R 0 0 MASONRY WALL (beyond) 8"x3G" CONCRETE TIC BEAM w/ (2) #55 TOP, BOTTOM 4 MIDDLE and #3 STIRRUPS @ I G" O.C. TOP @ + 13-0" A.F.F. Oj #5 REBAR ?n FILLED CELL COLUMN refer to plank for locations E 0 m 0 0 o - Z C W d m d a L a 3 v n 0 Q N Y O O 0 0 m rn 0 i o U 2 in N m 3 0 0 i a RAILING per ARCH G" nominal CONCRETE SLAB w/ #415 1 2" O.C. E.W. MASONRY WALL (beyond) FRANGIBLE ENTRY STOOP * STEPS refer to architecturals TILE ROOFING over 32" CDX PLYWOOD over WOOD TRUSSES by others WOOD ROOF TRU55E5 DE5IGNED DY' OTHER5. 5IMP50N HETA 20 typical at all trusses unless noted otherwise 8"x24" (3-COUR5E) BOND BEAM w/ (1) #5 cont. TOP $ BOTTOM - PRECAST LINTEL AT OPENINGS refer to schedule � details #5 REBAR in PILLED CELL COLUMN refer to plans for locations 9 TYPICAL 8" CMU I CONSTRUCTION - typical wall sectio E E g O M #5x8' REBAR w/ 30" LAP at FILLED CELL COLUMN STEEL IN MASONRY ABOVE $ BELOW E L o TYPICAL 8" CMU MASONRY CONSTRUCTION - refer to typical wall section sheet 5-8 I #5 REBAR LAP 30" w/ FILLED CELL COLUMN STEEL f 1: G" STRUCTURAL E CONCRETE SLAB w/ ir. #4'5 1 2" O.C. E.W. �._........... ................. ...... .........._ Frame Ceiling by ---1 2" HOOK CONTRACTOR <' 8"x24" CONCRETE TIE BEAM 8"x 19";CONCRETE TIE BEAM w/ (2) #55 TOP t BOTTOM w/ (2) #,5'5 TOP * BOTTOM and #3 STIRRUPS @ I G" O.C. and #3STIRRUP5 @ I G" O.C. TOP @ +0'-0" Finish Floor TOP @( -0'-1 " B.F.F. 8"x24" (3-COUR5E) BOND BEAM w/ (1) #5 cont. TOP BOTTOM - PRECAST LINTEL AT OPENINGS refer to schedule * details SIMPSON META 20 typical at all trusses unless noted otherwise FRANGIBLE MASONRY (beyond) �FKflFT3A 11 ;..�T I�FT TILE ROOFING over 32" CDX PLYWOOD over WOOD TRUSSES by others SIMPSON HETA 20 \� typical at all trusses \\ unless noted otherwise Is 4" thick 3000psi CONCRETE E I 4" thick 3000ps1 CONCRETE SLAB - TYPICAL SHEARWALL FOOTING ELEVATOR PIT t- ASSOCIATED 4" thick 3000ps1 CONCRETE SLAB - SLAB - FIBERMESH REINF. - g TYPICAL FRANGIBLE FOOTING FIBERMESH REINF. - FRANGIBLE - - refer to details sheet 5-9 PILING and FOUNDATION (before) FIBERMESH REINF. -FRANGIBLE - g FRANGIBLE -SAW CUT into 5'x5' SAW CUT Into 5'x5' max. SECTIONS mak. SECTIONS - refer to plans g - refer to details sheet 5-9 SAW CUT Into 5'x5' max. SECTIONS �m refer to plans and details m O - refer to plans for cut locations for,, out locations O 1s c w - J w ca L T CP L.J • U ;~ Z U N V1 W M E M M bA � O �W �x 9z z z � w w�Qneq ex � ZF � V �* vi x � r z h�l 2011 max. Z Z ._:. ._ ..... _..... ..,. r� U � C) J h°VI refer to plans for cut locations : I CC$ 17 - MM � l 0 24"501. SHEARWALL FOOTING. refer to plans details (before) 1 2"x 1 2" THICKENED EDGE f 2 # CONT (frangible) w/ O 5's N .............. .............. / .`` G" AUGER CAST PILE AND ... AUGER -CAST PILE AND » » I G" AUGER -CAST PILE I G" AUGER -CAST PILE TYPICAL (before) TYPICAL (before) BUILDING 24"s TRANSITION CAP 5ECTION a I refer to plans * details 24" TRANSITION CAP refer to plans � details I G AUGER -CAST FIL4 TYPICAL (beyond) 1 SCALE: 112" _ 1 5-7 PRoJEC T No. THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS S.AMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL 0 JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. 16-039 CONTRACTOR SHALL C 00 F D I NATE ALL DETAILS AND SHEET � CONSTRUCTION. S-7 ELEVATIONS WITH AR:c�HITE_�T PRIOR TO E N m 0 0 z° 0 0 m a a a .o 3 n 0 U F- V) Y 0 0 0 X m oD n 0 1 10 0 in 0 0 / d a 0 0 0 C O E En 0 to CID -13 THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set' , DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. 5IMP50N HETA 20 typical at all trusses unless noted otherwise REFER TO ARCHITECTURAL PLANS FOR FASCIA, SOFFIT * DRIP EDGE DETAILS REFER TO ARCHITECTURAL PLANS FOR INTERIOR OEXTERIOR WALL FINISHES #5 REBAR in FILLED CELL COLUMN refer to plans for locations 5IMP50N HETA 20 typical at all trusses unless noted otherwise TILE ROOFING over 32" O CDX PLYWOD over WOOD TRUSSES by others - 8"x24" (3-COURSE) BOND BEAM w/ (1) #5 cont. TOP BOTTOM - PRECAST LINTEL AT OPENINGS REFER TO ARCHITECTURAL • refer to schedule details PLANS FOR FASCIA, SOFFI- - --- --- - ----- -- DRIP EDGE DLTAILS? #5 REBAR in FILLED CELL COLUMN frefer to plans for locations REFER TO ARCHITECTURAL PLANS FOR INTERIOR EXTERIORWALL FINISHES TYPICAL 8" CMU MASONRY CONSTRUCTION - refer to Itypical wall section at right 0 � 1� I ELEVATOR SHAFT (beyond) TYPICAL 8" CMU MASONRY CONSTRUCTION . I ............. t '• zf #5x50" REBAR w/ 30" LAP I. I I : at FILLED CELL COLUMN STEEL IN MASONRY ABOVE TILE ROOFING over CDX PLYWOOD over WOOD TRUSSES by others o ' f r GYP-CRETE OVER '•, PLYWOOD SUBFLOOK _......,,_...__._ _..._ ._.,..,...____ \._.,......_ 2;x4 (or better) P.T ` FONT. NAILER COFFER CEILING _._------------- �..... ... ........_ _...._,,. �._.. _ _ ...,.._.,,,. ......... ...__ .. refer to architecturals ' CONCRETE TIE BEAM 8"x26" (32-COURSE) BOND EMBEDDE STEEL refer to plans * schedule BEAM w/ (1) #5 cont. TOP WELq PLATE * BOTTOM - PRECAST (before) LINTEL- AT OPENINGS refer to?details refer to schedule $ details I TYPICAL 8" CMU MASONRY 1 CONSTRUCTION - refer to typical wall section at right #5x50" REBAR LAP 30" w/ FILLED CELL COLUMN STEEL E Q LAP VERTICAL STEEI 0 A MINIMUM OF 48 (9 k;. BAR DIAMETERS G" nominal 3000p51 CONCRETE SLAB w/ #4's 1 2" O.C. E.W. 12" HOOK 8"x24" CONCRETE TIE BEAM € w/ (2) #5'5 TOP * BOTTOMS ........................2, 8.._.................... and #3 STIRRUPS @ I G" O.C. CAN I ILCVCK STUB #5 REBAR into CONCRETE BEAM max. G" embedment #5 REBAR in FILLED CELL COLUMN refer to plans for locations STUB #5 REBAR into TRANSITION CAP max. G" embedment I G" AUGER -CAST PILE 24"5q. TRANSITION CAP refer to plans * details GYP-CRETE OVER PLYWOOD SUBFLOOP, 2x4 PT. CONT. NAILED? W0017 FLOOR TRUSSES:'• (ty icap DES16N?ED BY OTHERS '............._..__................................................._...._.......... ..... ®.............._.__..._........._.....�I.........................._.................i�l............................._:: _ f-2-3z3G-60NCRETE TIE BEAM w/ (2) #5'� TOP * BOTTOM (bottom of beam @ top of window elevation) FRANGIBLE I?" CMU MASONRY CONSTRUCTIO 0 N ELEVATOR SHAFT (beyond) TUBE STEEL TYPICAL 8" CMU MASONRY COLUMN (before) CONSTRUCTION refer to details ANCHORED STEEL 4" thick 30001251 CONCRETE SLAB - WELD PLATE r--FIBERMESH REINF. - FRANGIBLE - (before) SAW CUT into 5'x5' max. SECTIONS refer to details - refer to plans for cut locations I G" AUGER -CAST PILE AND 24" TRANSITION CAP (before) WALL SECTION �3� SCALE: 112" = 1'-0" SIMPSON META 20 typical at all trusses unless noted otherwise REFER TO ARCHITECTURAL PLANS FOR FASCIA, SOFFIT * DRIP EDGE DETAILS REFER TO ARCHITECTURAL PLANS FOR INTERIOR � EXTERIOR WALL FINISHES E 0- TILE ROOFING over32 CDX PLYWOOD over WOOD p TRUSSES by othersn SIMFSON HETA 20 apical at all trusses iy unless noted otherwise TO ARCHITECTURAL -0R FASCIA,! SOFFIT DRIP EDGE DETAILS 8"x28" (32 COUR$Q BOND BEAM w/ (1) #5 co nt. TOP * BOTTOM - PRE(tAST LINTEL AT OFENINGS refer to schedule ® details _FER TO ARCHITECTURAL---` :PLANS FOR INTERIOR -XTERIOR WALL FINISHES TYPICAL " CMU MA-4ONRY O ; CONSTRICTION - refs to typical wall section atricjht #5 REBAR in FILLED CELL COLUMN refer to plans for locations TILE ROOFING over 32" CDX PLYWOOD over WOOD TRUSSES by others WOOD ROOF TRUSSES DESIGNED BY OTHERS. 8"x24" (3-COUR5E) BOND BEAM w/ (1) #5 cont. TOP * BOTTOM - PRECAST LINTEL AT OPENINGS refer to schedule * details #5 REBAR in FILLED ICE COLUMN refer to plans for locatio TYPICAL 8" CMU MASONRY CONSTRUCTION - refer to typical wall section at right #5x50" REBAR w/ 30? LAP at FILLED CELL COLUMN; STEEL IN MASONRY ABOVE I (2) 2x 10 P.T. LEDGER -5/b"x7' WEDGE ANCHORS @ 24" O.C. STAGGERED GYP CRETE OVER PLYWOOb SUBFLOOR ............. . WOOD FLOOR TRUSSES DESIGNED BY OTHERS 7z depth to be determined 8"x24" CONCRETE TIE BEAM w/ (2) #5's TOP * BOTTOM and #3 STIRRUPS @ I G" O.C. TOP @ + 1 3'-0" A.F.F. i L` A,560" REBAR LAP 30" w/ FILLED l CELL COLUMNSTEEL E I (2) 2x 10 P:T• LEDGER Q I 5/g'x7" WEDGE ANCHORS @ LAf VERTICAL 124" I (` O.C. STAGGERED ( A MINIMUM Off BAR DIAMETE4GYP CRETE OVER PLYWOOD SUBFLOOR....... .......... ) . ..............._..._.. �. 's6 nominal3000P51-7Z :CONCRETE SLAB w/ WOOD FLOOR TRUSSES #4'5 12" O.C. E.W. DESIGNED BY OTHERS depth to be determined 12"HOOK 8"x24' CONCRETE TIE BEAM w/ (�) #5'5 TOP $ BOTTOM `• ` and #3'=:=:5TIRRUP5 @ I G" O.C. CANTILEVERji ' I G"x42" CONCRETE TIE BEAM w/ (3) #5'5 TOP It BOTTOM and #3 STIRRUPS @ I G" O.C. TOP @ +0'-0" finish Floor i FORM -POURED CONCRETE COLUMN refer to plans * schedule o FRANGIBLE MASONRY (beyond) I i 4" thick 3000p5i CONCRETE SLAB - FIBERMLSH REINF. - FRANGIBLE - I RECESS FOR GARAGE SAW CUT into 5'x5' max. SECTIONS (4) STANDARD HOOKS-± -nr,,p --Z-- �- A-4-1 -refer to plans for cut locations —�r TRANSITION CAP refer to plans * details SCALE: 112" = 1 '-0" CONSTRUCTIONS T METAL ROOFING over 3 , CDX PLAWWOOD over WOOD TRUSSES by others SIMPSON META 20 typical at all trusses unless noted otherwise REFER TO ARCHITECTURAL PLANS FOR rASCIA, SOFFIT DRIP EDGE DETAILS _I REFER TO ARCHITECTURAL PLANS FOR INTERIOR � EXTERIOR WALL FINISHES j c::i"ccz 3 8"x24" CONCRrTL TIE BEAM ip w/ (2) #5'5 TOP BOTTOM =. and #3 STIRRUPS @ 16" O.C. TOP @ +0'-O" Finish Floor 8"x28" (32-COURSE) BOND BEAM w/ (1) #5 cont. TOP * BOTTOM - PRECAST LINTEL AT OPENINGS refer to schedule � details �-TYPICAL 8" C.M.U. MASONRY WALL w/ 9ga. LADDER TYPE HORIZONTAL REINFORCEMENT AT EVERY OTHER COURSE (I G" O.C.) * #5 vert. IN FILLED CELL COLUMN AS INDICATED ON PLANS �-FILLED CELL COLUMNS SHALL BE LOCATED MAX. 4'-0" O.C. � ... a) EACH SIDE OF ANY OPENING b) AT ALL CORNERS c) AT ALL WALL ELEVATION CHANGES d) AS INDICATED ON PLAN #5x50" REBAR LAP 30" w/ -FILLED CELL COLUMN STEEL -2x P.T. CONT. NAILER GYP-CRETE OVER PLYWOOD SUBFLOOR .................... #PRE ENGINEERED rLC OR I TRUSSES @ 24"IOjC. 3 ra ivniviivi�ivi vi -tc� BAR DIAMETERS E g Cif O 4" min. CURB m TYPICAL @GARAGE SLAB PERIMETER :... •V •rI rI STANDARD 10"w® ^ Q� HOOK I v 1 E l.. 4" thick 3000p5i CONCRETE SLAB FIBERMESH REINF. - FRANGIBLE I G" AUGER -CAST FILE SAW CUT into 5'x5' max. SECTIONS 24"5q. TRANSITION CAP refer to plans for cut locations `' - refer to plans * details TYPICAL WALL SCALE: I /2" = I ' 0" SECTION CONTRACTOR (-'--' HALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. - SHrLT S-8- COFFER CEILING _._------------- �..... ... ........_ _...._,,. �._.. _ _ ...,.._.,,,. ......... ...__ .. refer to architecturals ' CONCRETE TIE BEAM 8"x26" (32-COURSE) BOND EMBEDDE STEEL refer to plans * schedule BEAM w/ (1) #5 cont. TOP WELq PLATE * BOTTOM - PRECAST (before) LINTEL- AT OPENINGS refer to?details refer to schedule $ details I TYPICAL 8" CMU MASONRY 1 CONSTRUCTION - refer to typical wall section at right #5x50" REBAR LAP 30" w/ FILLED CELL COLUMN STEEL E Q LAP VERTICAL STEEI 0 A MINIMUM OF 48 (9 k;. BAR DIAMETERS G" nominal 3000p51 CONCRETE SLAB w/ #4's 1 2" O.C. E.W. 12" HOOK 8"x24" CONCRETE TIE BEAM € w/ (2) #5'5 TOP * BOTTOMS ........................2, 8.._.................... and #3 STIRRUPS @ I G" O.C. CAN I ILCVCK STUB #5 REBAR into CONCRETE BEAM max. G" embedment #5 REBAR in FILLED CELL COLUMN refer to plans for locations STUB #5 REBAR into TRANSITION CAP max. G" embedment I G" AUGER -CAST PILE 24"5q. TRANSITION CAP refer to plans * details GYP-CRETE OVER PLYWOOD SUBFLOOP, 2x4 PT. CONT. NAILED? W0017 FLOOR TRUSSES:'• (ty icap DES16N?ED BY OTHERS '............._..__................................................._...._.......... ..... ®.............._.__..._........._.....�I.........................._.................i�l............................._:: _ f-2-3z3G-60NCRETE TIE BEAM w/ (2) #5'� TOP * BOTTOM (bottom of beam @ top of window elevation) FRANGIBLE I?" CMU MASONRY CONSTRUCTIO 0 N ELEVATOR SHAFT (beyond) TUBE STEEL TYPICAL 8" CMU MASONRY COLUMN (before) CONSTRUCTION refer to details ANCHORED STEEL 4" thick 30001251 CONCRETE SLAB - WELD PLATE r--FIBERMESH REINF. - FRANGIBLE - (before) SAW CUT into 5'x5' max. SECTIONS refer to details - refer to plans for cut locations I G" AUGER -CAST PILE AND 24" TRANSITION CAP (before) WALL SECTION �3� SCALE: 112" = 1'-0" SIMPSON META 20 typical at all trusses unless noted otherwise REFER TO ARCHITECTURAL PLANS FOR FASCIA, SOFFIT * DRIP EDGE DETAILS REFER TO ARCHITECTURAL PLANS FOR INTERIOR � EXTERIOR WALL FINISHES E 0- TILE ROOFING over32 CDX PLYWOOD over WOOD p TRUSSES by othersn SIMFSON HETA 20 apical at all trusses iy unless noted otherwise TO ARCHITECTURAL -0R FASCIA,! SOFFIT DRIP EDGE DETAILS 8"x28" (32 COUR$Q BOND BEAM w/ (1) #5 co nt. TOP * BOTTOM - PRE(tAST LINTEL AT OFENINGS refer to schedule ® details _FER TO ARCHITECTURAL---` :PLANS FOR INTERIOR -XTERIOR WALL FINISHES TYPICAL " CMU MA-4ONRY O ; CONSTRICTION - refs to typical wall section atricjht #5 REBAR in FILLED CELL COLUMN refer to plans for locations TILE ROOFING over 32" CDX PLYWOOD over WOOD TRUSSES by others WOOD ROOF TRUSSES DESIGNED BY OTHERS. 8"x24" (3-COUR5E) BOND BEAM w/ (1) #5 cont. TOP * BOTTOM - PRECAST LINTEL AT OPENINGS refer to schedule * details #5 REBAR in FILLED ICE COLUMN refer to plans for locatio TYPICAL 8" CMU MASONRY CONSTRUCTION - refer to typical wall section at right #5x50" REBAR w/ 30? LAP at FILLED CELL COLUMN; STEEL IN MASONRY ABOVE I (2) 2x 10 P.T. LEDGER -5/b"x7' WEDGE ANCHORS @ 24" O.C. STAGGERED GYP CRETE OVER PLYWOOb SUBFLOOR ............. . WOOD FLOOR TRUSSES DESIGNED BY OTHERS 7z depth to be determined 8"x24" CONCRETE TIE BEAM w/ (2) #5's TOP * BOTTOM and #3 STIRRUPS @ I G" O.C. TOP @ + 1 3'-0" A.F.F. i L` A,560" REBAR LAP 30" w/ FILLED l CELL COLUMNSTEEL E I (2) 2x 10 P:T• LEDGER Q I 5/g'x7" WEDGE ANCHORS @ LAf VERTICAL 124" I (` O.C. STAGGERED ( A MINIMUM Off BAR DIAMETE4GYP CRETE OVER PLYWOOD SUBFLOOR....... .......... ) . ..............._..._.. �. 's6 nominal3000P51-7Z :CONCRETE SLAB w/ WOOD FLOOR TRUSSES #4'5 12" O.C. E.W. DESIGNED BY OTHERS depth to be determined 12"HOOK 8"x24' CONCRETE TIE BEAM w/ (�) #5'5 TOP $ BOTTOM `• ` and #3'=:=:5TIRRUP5 @ I G" O.C. CANTILEVERji ' I G"x42" CONCRETE TIE BEAM w/ (3) #5'5 TOP It BOTTOM and #3 STIRRUPS @ I G" O.C. TOP @ +0'-0" finish Floor i FORM -POURED CONCRETE COLUMN refer to plans * schedule o FRANGIBLE MASONRY (beyond) I i 4" thick 3000p5i CONCRETE SLAB - FIBERMLSH REINF. - FRANGIBLE - I RECESS FOR GARAGE SAW CUT into 5'x5' max. SECTIONS (4) STANDARD HOOKS-± -nr,,p --Z-- �- A-4-1 -refer to plans for cut locations —�r TRANSITION CAP refer to plans * details SCALE: 112" = 1 '-0" CONSTRUCTIONS T METAL ROOFING over 3 , CDX PLAWWOOD over WOOD TRUSSES by others SIMPSON META 20 typical at all trusses unless noted otherwise REFER TO ARCHITECTURAL PLANS FOR rASCIA, SOFFIT DRIP EDGE DETAILS _I REFER TO ARCHITECTURAL PLANS FOR INTERIOR � EXTERIOR WALL FINISHES j c::i"ccz 3 8"x24" CONCRrTL TIE BEAM ip w/ (2) #5'5 TOP BOTTOM =. and #3 STIRRUPS @ 16" O.C. TOP @ +0'-O" Finish Floor 8"x28" (32-COURSE) BOND BEAM w/ (1) #5 cont. TOP * BOTTOM - PRECAST LINTEL AT OPENINGS refer to schedule � details �-TYPICAL 8" C.M.U. MASONRY WALL w/ 9ga. LADDER TYPE HORIZONTAL REINFORCEMENT AT EVERY OTHER COURSE (I G" O.C.) * #5 vert. IN FILLED CELL COLUMN AS INDICATED ON PLANS �-FILLED CELL COLUMNS SHALL BE LOCATED MAX. 4'-0" O.C. � ... a) EACH SIDE OF ANY OPENING b) AT ALL CORNERS c) AT ALL WALL ELEVATION CHANGES d) AS INDICATED ON PLAN #5x50" REBAR LAP 30" w/ -FILLED CELL COLUMN STEEL -2x P.T. CONT. NAILER GYP-CRETE OVER PLYWOOD SUBFLOOR .................... #PRE ENGINEERED rLC OR I TRUSSES @ 24"IOjC. 3 ra ivniviivi�ivi vi -tc� BAR DIAMETERS E g Cif O 4" min. CURB m TYPICAL @GARAGE SLAB PERIMETER :... •V •rI rI STANDARD 10"w® ^ Q� HOOK I v 1 E l.. 4" thick 3000p5i CONCRETE SLAB FIBERMESH REINF. - FRANGIBLE I G" AUGER -CAST FILE SAW CUT into 5'x5' max. SECTIONS 24"5q. TRANSITION CAP refer to plans for cut locations `' - refer to plans * details TYPICAL WALL SCALE: I /2" = I ' 0" SECTION CONTRACTOR (-'--' HALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. - SHrLT S-8- WALL SECTION �3� SCALE: 112" = 1'-0" SIMPSON META 20 typical at all trusses unless noted otherwise REFER TO ARCHITECTURAL PLANS FOR FASCIA, SOFFIT * DRIP EDGE DETAILS REFER TO ARCHITECTURAL PLANS FOR INTERIOR � EXTERIOR WALL FINISHES E 0- TILE ROOFING over32 CDX PLYWOOD over WOOD p TRUSSES by othersn SIMFSON HETA 20 apical at all trusses iy unless noted otherwise TO ARCHITECTURAL -0R FASCIA,! SOFFIT DRIP EDGE DETAILS 8"x28" (32 COUR$Q BOND BEAM w/ (1) #5 co nt. TOP * BOTTOM - PRE(tAST LINTEL AT OFENINGS refer to schedule ® details _FER TO ARCHITECTURAL---` :PLANS FOR INTERIOR -XTERIOR WALL FINISHES TYPICAL " CMU MA-4ONRY O ; CONSTRICTION - refs to typical wall section atricjht #5 REBAR in FILLED CELL COLUMN refer to plans for locations TILE ROOFING over 32" CDX PLYWOOD over WOOD TRUSSES by others WOOD ROOF TRUSSES DESIGNED BY OTHERS. 8"x24" (3-COUR5E) BOND BEAM w/ (1) #5 cont. TOP * BOTTOM - PRECAST LINTEL AT OPENINGS refer to schedule * details #5 REBAR in FILLED ICE COLUMN refer to plans for locatio TYPICAL 8" CMU MASONRY CONSTRUCTION - refer to typical wall section at right #5x50" REBAR w/ 30? LAP at FILLED CELL COLUMN; STEEL IN MASONRY ABOVE I (2) 2x 10 P.T. LEDGER -5/b"x7' WEDGE ANCHORS @ 24" O.C. STAGGERED GYP CRETE OVER PLYWOOb SUBFLOOR ............. . WOOD FLOOR TRUSSES DESIGNED BY OTHERS 7z depth to be determined 8"x24" CONCRETE TIE BEAM w/ (2) #5's TOP * BOTTOM and #3 STIRRUPS @ I G" O.C. TOP @ + 1 3'-0" A.F.F. i L` A,560" REBAR LAP 30" w/ FILLED l CELL COLUMNSTEEL E I (2) 2x 10 P:T• LEDGER Q I 5/g'x7" WEDGE ANCHORS @ LAf VERTICAL 124" I (` O.C. STAGGERED ( A MINIMUM Off BAR DIAMETE4GYP CRETE OVER PLYWOOD SUBFLOOR....... .......... ) . ..............._..._.. �. 's6 nominal3000P51-7Z :CONCRETE SLAB w/ WOOD FLOOR TRUSSES #4'5 12" O.C. E.W. DESIGNED BY OTHERS depth to be determined 12"HOOK 8"x24' CONCRETE TIE BEAM w/ (�) #5'5 TOP $ BOTTOM `• ` and #3'=:=:5TIRRUP5 @ I G" O.C. CANTILEVERji ' I G"x42" CONCRETE TIE BEAM w/ (3) #5'5 TOP It BOTTOM and #3 STIRRUPS @ I G" O.C. TOP @ +0'-0" finish Floor i FORM -POURED CONCRETE COLUMN refer to plans * schedule o FRANGIBLE MASONRY (beyond) I i 4" thick 3000p5i CONCRETE SLAB - FIBERMLSH REINF. - FRANGIBLE - I RECESS FOR GARAGE SAW CUT into 5'x5' max. SECTIONS (4) STANDARD HOOKS-± -nr,,p --Z-- �- A-4-1 -refer to plans for cut locations —�r TRANSITION CAP refer to plans * details SCALE: 112" = 1 '-0" CONSTRUCTIONS T METAL ROOFING over 3 , CDX PLAWWOOD over WOOD TRUSSES by others SIMPSON META 20 typical at all trusses unless noted otherwise REFER TO ARCHITECTURAL PLANS FOR rASCIA, SOFFIT DRIP EDGE DETAILS _I REFER TO ARCHITECTURAL PLANS FOR INTERIOR � EXTERIOR WALL FINISHES j c::i"ccz 3 8"x24" CONCRrTL TIE BEAM ip w/ (2) #5'5 TOP BOTTOM =. and #3 STIRRUPS @ 16" O.C. TOP @ +0'-O" Finish Floor 8"x28" (32-COURSE) BOND BEAM w/ (1) #5 cont. TOP * BOTTOM - PRECAST LINTEL AT OPENINGS refer to schedule � details �-TYPICAL 8" C.M.U. MASONRY WALL w/ 9ga. LADDER TYPE HORIZONTAL REINFORCEMENT AT EVERY OTHER COURSE (I G" O.C.) * #5 vert. IN FILLED CELL COLUMN AS INDICATED ON PLANS �-FILLED CELL COLUMNS SHALL BE LOCATED MAX. 4'-0" O.C. � ... a) EACH SIDE OF ANY OPENING b) AT ALL CORNERS c) AT ALL WALL ELEVATION CHANGES d) AS INDICATED ON PLAN #5x50" REBAR LAP 30" w/ -FILLED CELL COLUMN STEEL -2x P.T. CONT. NAILER GYP-CRETE OVER PLYWOOD SUBFLOOR .................... #PRE ENGINEERED rLC OR I TRUSSES @ 24"IOjC. 3 ra ivniviivi�ivi vi -tc� BAR DIAMETERS E g Cif O 4" min. CURB m TYPICAL @GARAGE SLAB PERIMETER :... •V •rI rI STANDARD 10"w® ^ Q� HOOK I v 1 E l.. 4" thick 3000p5i CONCRETE SLAB FIBERMESH REINF. - FRANGIBLE I G" AUGER -CAST FILE SAW CUT into 5'x5' max. SECTIONS 24"5q. TRANSITION CAP refer to plans for cut locations `' - refer to plans * details TYPICAL WALL SCALE: I /2" = I ' 0" SECTION CONTRACTOR (-'--' HALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. - SHrLT S-8- TRANSITION CAP refer to plans * details SCALE: 112" = 1 '-0" CONSTRUCTIONS T METAL ROOFING over 3 , CDX PLAWWOOD over WOOD TRUSSES by others SIMPSON META 20 typical at all trusses unless noted otherwise REFER TO ARCHITECTURAL PLANS FOR rASCIA, SOFFIT DRIP EDGE DETAILS _I REFER TO ARCHITECTURAL PLANS FOR INTERIOR � EXTERIOR WALL FINISHES j c::i"ccz 3 8"x24" CONCRrTL TIE BEAM ip w/ (2) #5'5 TOP BOTTOM =. and #3 STIRRUPS @ 16" O.C. TOP @ +0'-O" Finish Floor 8"x28" (32-COURSE) BOND BEAM w/ (1) #5 cont. TOP * BOTTOM - PRECAST LINTEL AT OPENINGS refer to schedule � details �-TYPICAL 8" C.M.U. MASONRY WALL w/ 9ga. LADDER TYPE HORIZONTAL REINFORCEMENT AT EVERY OTHER COURSE (I G" O.C.) * #5 vert. IN FILLED CELL COLUMN AS INDICATED ON PLANS �-FILLED CELL COLUMNS SHALL BE LOCATED MAX. 4'-0" O.C. � ... a) EACH SIDE OF ANY OPENING b) AT ALL CORNERS c) AT ALL WALL ELEVATION CHANGES d) AS INDICATED ON PLAN #5x50" REBAR LAP 30" w/ -FILLED CELL COLUMN STEEL -2x P.T. CONT. NAILER GYP-CRETE OVER PLYWOOD SUBFLOOR .................... #PRE ENGINEERED rLC OR I TRUSSES @ 24"IOjC. 3 ra ivniviivi�ivi vi -tc� BAR DIAMETERS E g Cif O 4" min. CURB m TYPICAL @GARAGE SLAB PERIMETER :... •V •rI rI STANDARD 10"w® ^ Q� HOOK I v 1 E l.. 4" thick 3000p5i CONCRETE SLAB FIBERMESH REINF. - FRANGIBLE I G" AUGER -CAST FILE SAW CUT into 5'x5' max. SECTIONS 24"5q. TRANSITION CAP refer to plans for cut locations `' - refer to plans * details TYPICAL WALL SCALE: I /2" = I ' 0" SECTION CONTRACTOR (-'--' HALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. - SHrLT S-8- TYPICAL WALL SCALE: I /2" = I ' 0" SECTION CONTRACTOR (-'--' HALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. - SHrLT S-8- CONSTRUCTIONS T E CN 0 z C O N a ta cL a 3 M o J of D U U Y U o 0 0 m m rn o i i a V 3 0 a J N O 0 o o v) 0 refer to TYPICAL WALL SECTION (sheet 5-5) for masonry construction specifications TYPICAL 8" CMU MA50NRY CONSTRUCTION 4" thick 3000p5i CONCRETE l SLAB - FIBERME5H REINF. - I' FRANGIBLE - SAW CUT into 5'x5' max. SECTIONS - refer 1... to plans for cut locations 4 MIN. CURB—\ STANDARD I. HOOK FINISH GRADE._..____ �0 18"deep x 1 2' N 3000p5i CONCRETE T O MONOLITHIC FOOTER (2) #5'5 (3" MIN. PROTECTION) Emil VISQUEEN VAPOR BARRIER DISCONTINUE STEEL MIN. 3" FROM over TERMITE TREATED COMPACTED TRANSITION CAP - refer to TYPICAL PILE FILL (96% max. density) @ PILE CAP detail sheet 5-3 similar " TRANSITION CAP (2) #5'5 SHALL BE CONTINUOUS (beyond) AT ALL 5HEARWALL FOOTINGS - refer to plans for locations AUGER CAST PILE (beyond) OUNDATION SECTION SCALE: 3/4" = I '-0" refer to TYPICAL WALL SECTION (-iheet 5-8) for masonry construction specifications TYPICAL 8" CMU 4" thick .3000p5; CONCRETE MASONRY SLAB - FIBERMt5H REINF. - CONSTRUCTION FRANGIBLE - SAW CUT into 5'x5' max. SECTIONS - refer to plans for cut locations STANDARD HOOK FINISH GRADE 1 18"deep x 1 2" 1 N 3000p5i CONCRETE 0 0 MONOLITHIC FOOTER Gmil VISQUEEN VAPOR BARRIER (2) #5'5 (3" MIN. PROTECTION) over TERMITE TREATED COMPACTED DISCONTINUE STEEL MIN, 3 FROM TRANSITION CAP - refer to TYPICAL PILE 1 FILL (98% max. density) @ PILE CAP detail sheet 5-3 (similar) 1 2;;........ TRANSITION CAP (2) #5'5 SHALL BE CONTINUOUS (beyond) AT ALL 5HEAKWALL FOOTINGS - refer to plans for locations AUGER CAST PILE (beyond) FOUNDATION SECTION SCALE: 3/4" = I '-0" 4" thick 3000p5; CONCRETE SLAB - FIBERME511 REINF. - FRANGIBLE - SAW CUT into 5'x5' max. SECTIONS - refer to plans for cut locations refer to TYPICAL WALL SECTION (sheet 5-8) for masonry construction specifications F2 STANDARD elevation changes may occur at HOOK SHEAR WALL FOOTING - refer to plans for locations i 6O, . clean termite treated granular file N clean termite treated granular fill 24" x 24" deep FOOTING w/ (3) #5's "'"', "` "" CLEAN OUT G" BELOW TOP CONT. (top * bottom) * #3 STIRRUPS OF PILE PRIOR TO BEAM @ I G" O.C. - TYPICAL at ALL SHEAR CONSTRUCTION WALL5 $ ELEVATOR WALLS .::'`�:.._.............. 1 8" .......,.,........fit: 3" MIN. PILE' TYPICAL AUGER CAST PILE EMBEDMENT REFER TO DETAILS I G" refer to TYPICAL WALL SECTION refer to TYPICAL WALL SECTION (sheet 5-8) for masonry (sheet S-8) for masonry construction specifications construction specifications 4" thick 3000p5; CONCRETE 4" thick 3000p51 CONCRETE SLAB - FIBERMESH REINF. - STANDARD STANDARD I SLAB - FIBERMESH REINF. - FRANGIBLE -SAW CUT into HOOK HOOK FRANGIBLE -SAW CUT into 5'x5' max. SECTIONS - refer 5'x5' max. SECTIONS - refer to to plans for cut locations I plans for cut locations 7" STRUCTURAL SLAB clean term to Ln (elevator pit base) - #4'5 treated granular fill 12" O.C.E.W. 18"x24" deep ELEVATOR SHAFT FOUNDATION w/ (3) #55 CONT. (top bottom) * #2 TIES @ I G" O.C. - TYPICAL @ TYPICAL AUGER CAST FILE ELEVATOR PERIMETER REFER TO DETAILS (beyond) 2" MIN COVERAGE typ. for all slab steel ELEVATOR PIT DETAIL SCALE: 3/4" = 1'-0" refer to TYPICAL WALL SECTION (sheet 5-8) for masonry construction specifications TYPICAL 8" CMU :I MASONRY- 4" thick 3000p5; CONCRETE CONSTRUCTION SLAB - FIBERME5H REINF. - FRANGIBLE - SAW CUT into 5'x5' max. SECTIONS -refer to plans for cut locations 4" THICK 3000p5; STEP - STANDARD FM REINFORCED refer to HOOK CONCRETE SLAB plans ------------ 77 18"deep x 1 2" N 3000p5i CONCRETE 0 o MONOLITHIC FOOTER (2) #5'5 CONT. Gmil VISQUEEN VAPOR BARRIER 3" MIN. PROTECTION - over TERMITE TREATED COMPACTED DISCONTINUE STEEL MIN. 3" _ FILL (98% max. density) FROM TRANSITION CAP - refer °"°\ 1 2"" to TYPICAL PILE @ PILE CAP TRANSITION CAP (beyond) detail sheet 5-3 (similar) AUGER CAST FILE (beyond) FOUNDATION SECTION SCALE: 3/4" = I '-0" 4" thick 3000p;i CONCRETE SLAB - FI13ERMP5H REINF. - CONCRETE COLUMN FRANGIBLE - SAW CUT into or MASONRY WALL 5'x5' max. SECTIONS - refer (beyond) to plans for cut locations 1/2" RECESS i. .. _.S _...._ ....._.. -------- _- o. PAVE�DRIVE 18"deep x 12" 1 3000p5i CONCRETE I C0 MONOLITHIC FOOTER _, Gmil VISQUEEN VAPOR BARRIER — over•: \(2) #5's CONT. TERMITE TREATED COMPACTED -" ---- i 7° :"° 3" MIN. PROTECTION - a•, FILL (98% max. density) DISCONTINUE STEEL MIN. 3" FROM TRANSITION CAP - refer TRANSITION CAP to TYPICAL PILE @ PILE CAP (beyond) detail sheet 5-3 (similar) AUGER CAST PILE (beyond) TYPICAL 5HEAR WALL FOOTING �`' FOUNDATION SECTIONI F6 SCALE: 3/4" = I'-0" SCALE: 3/4" = I'-0" 4" thick 3000p5i CONCRETE SLAB - FIBERME51­1 REINF. - FRANGIBLE - SAW CUT into 5'x5' max. SECTIONS - refer to plans for cut locations 4" STEP TYPICAL SLAB TRANSITION SCALE: 3/4" = 1 '-0" WINDOW FR/\ME--\ /4" x 311 TAPCON GLA`35 2x4 P.T BUCK JAMB DETAIL PRE EN WOOD CONCRETE OR BLOCK BEAM BUCK/FRAME ATTACHMENT 2x4 (MAX.) P.T. WINDOW BUCK �I #5 BAR (i (TYP . ) #5 CORNER BAR w/ 24" LEG II j COLUMN BELOW I I - - PRECAST 45 DEG. MITER CUT CPRECAST LINTEL ORNER LI NTEL CORNER DETAIL SCALE: 3/4" = I '-0" FILLED CELL MASONRY COLUMN W/ I #5 VERT. IN EA. CEL L, LAPPED @ O O FOOTING AND EXTENDED INTO TIE � o BEAM. FILL W/ 3000 PSI CONCRETE. (REFER TO PLAN AT LEFT FOR SPECIFIC LOCATIONS) FASTEN TO C.B.S. w//4"x2 4" MIN. FILLED CELL MASONRY COLUMN W/ 1 TAPCONS G" MAX. FROM ENDS AND #5 VERT. IN EA. CELL. LAPPED @ 1 2" O/C MAX. (TYP. THREE SIDES) El 11M O O FOOTING AND EXTENDED INTO TIE 1x3 (MIN.) P.T. WINDOW BUCK BEAM. FILL W/ 3000 PSI FASTEN TO C.B.S. w/ 3/6"x2/4" MIN. CONCRETE. (REFER TO PLAN AT LEFT TAPCONS G" MAX. FROM ENDS AND FOR SPECIFIC LOCATIONS) 1 2" O/C MAX. (TYP. THREE SIDES) OPTIONAL FASTENING (WINDOW & DOOR) OPTIONAL FASTENING: /4"x3"MIN. COLUMN DETAIL TAPCONS THRU FRAME, BUCK $ INTO C.B.S. (I 2" MIN. EMBEDMENT). TAPCONS REQ'D AT EACH SCREW SCALE: 3/4" = I '-0" LOCATION PROVIDED BYMANUFACTURER "DETAILS ABOVE DEPICT THIS OPTION- FILLED CELLS SHALL BE LOCATED NO FURTHER APART THAN 46" O.C., UNLE55 SPECIFICALLY DIMEN51ONED OTHEKW15E ON THE FOUNDATION PLAN. =D SIMPSON HETA20 CONNECTOR DETAILS SCALE: NOT TO SCALE C❑NDITI❑N #1; STRAP IS ❑' TO 3/8' AWAY FROM EDGE OF TRUSS. REPAIR; NO REPAIR NECESSARY, C❑NDITI❑N #2; STRAP IS 3/8' TO 1-1/2' AWAY FROM EDGE OF TRUSS. REPAIR; PLACE MAXIMUM 2x4 BLOCK BETWEEN TRUSS AND STRAP, BEND PER DETAIL AND NAIL 7-10d, C❑NDITI❑N #3; STRAP IS MORE THAN 1-1/2' AWAY FROM EDGE OF TRUSS. REPAIR; PER DETAIL SHOWN USING USP RT18112 ANCHORED TO WALL WITH (3) 1/4'x2-1/4' (MIN,) TAP -CONS AND NAILED TO TRUSS WITH 7-10d, MAXIMUM 1200 LBS. UPLIFT, APPLIES TO MULTIPLES AND C❑NSECUTIVE TRUSSES, AND MAY BE USED ON EITHER SIDE OF WALL, NOTE: USP-RT 1 61 12 MAY BE SUBSTITUTED WITH 51MP50N HT5M I G AT ANY LOCATION 1/4' X 2-1/4' TAPC❑NS SPACED Y AT LEAST 2' FROM TOP STRAP MISALIGNMENT REPAIR SCALE: not to scale THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, I�ONDITIONS AND CONTRACT DOCUMENTS. 0 �> CONTRACTOR R SHALL COORDINATE R D I HATE ALL DETAILS AN D ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. s ' w U ' o �Aoa� W � i Z r� O h xO a � V ~ O a p U 4_4 C) U I.-� c� U CC U � � //C) O � Q 17, 16-039 S-9. CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. CONSTRUCTIONS T E 0 0 z 0 ir a a r 3 M U ir 0 U U 0 0 m m 10 0 i 0 U i 0 o, c 0 0 a 0 J y c c 0 E 0 0 CONTRACTOR SHALL COORDINATE ELEVATION w/ FINISH SURFACE POOUPATI O EXTEND POUR AS NECESSARY TO COMPLETE STEPS - NO STEEL CONNECTION TO MAIN STRUCTURE 8"x8" C.M.U. MASONRY FILLED CELL COLUMN w/ (1) #50 vert. PROPOSED GRADE I GN I G" SPREAD FOOTING w/ (2) #5's Cont. I THE ILLUSTRATED STEPS ARE DESIGNED TO DE ENTIRELY INDEPENDANT OF THE MAIN STRUCTURE AND SHALL NOT DE CONNECTED IN ANY SIGNIFICANT MANNER L„ I 1 _:J #4 "LONG" STEEL G) ,— #4 "SHORT" STEEL �s 8"x 18"deep CONC. - 1- BEAM w/ (4) #4'5 #2 I G"x8" C.M.U. Q STIRRUPS @ I G" o.c. QMASONRY FILLED J J ^ CELL COLUMN w/ - (2) #5 s vert. I GN(5" C.M.U. STANDARD �j O MASONRY FILLED ' m O 8" HOOK CELL COLUMN w/- m I (long direction) IJT (2) #5's vert. IBLE FOOTER w/ (2) #5 BARS Cont. STANDARD 8" HOOK (long direction) �, �, CENTER -TO -CENTER of COLUMNS CENTER -TO -CENTER of COLUMNS COLUMN CENTER to FOOTING CENTER EXTERKDRE� IDETAIL FORM -POURED CONC. STEPS w/ (4) #4'5 @ 1 0" o.c. (long) #4'5 @ 1 4" o.c. (short) 8" min. CONC. THICKNESS \ ) T t I G"x I G" S11 PRE1. AI FOOTING w/ (2) #5's Cont. SCALE: 112" = I '-0" refer to sheet 5-4 1 v 17-0" f_XTERIOR STEMS fOUNDATION PLAN_.,_ SCALE: 1 /4" = I '-0" THESE PLANS ARE NOT FOR CON§TRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNEd AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN POMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIdNS AND CONTRACT DOCUMENTS. IVA a #4x30N24" STAIR 'HOOK"- TYP. at each "LONG" STEEL PROPOSED GRADE TO BE ADJUSTED TO COINCIDE WITH STEPS N CONSTRUCTION 12"x24" CONCRETE SPREAD E FOOTING (FIRST READ/RISER) w/ (2) #5'5 T*B � #3 STIRRUPS @ I G" O.C. E �e Pik C 4" thick 3000p51 CONCRETE SLAB - FIBERMESH REINF. - FRANGIBLE - SAW CUT into E 5'x5' max. SECTIONS - refer to plans for cut locations"" VAPOR BARRIER clean termite treated granular Ni N 20" x 24" deep FOOTING w/ (3) #5'5 "` CONT. (top * bottom) * #3 STIRRUPS @ I G" O.C. - TYPICAL at ALL SHEAR WALLS � ELEVATOR WALLS20 E 3" MIN. PILE EMBEDMENT refer to TYPICAL WALL SECTION (sheet 5-8) for masonry construction specifications CURB TYPICAL AT GARAGE PERIMETER - VARIES BETWEEN 4" min. $ G" max. (94" WIDE typ.) - STANDARD HOOK TYPICAL AUGER CAST PILE REFER TO DETAILS f ............... 511EAR WALL FOOTING w/ CURBF SCALE: 3/4'= I'-0" refer to TYPICAL WALL SECTION (sheet 5-8) for masonry construction specifications r. 4" thick 3000p5i CONCRETE SLAB - FIBERMESH REINF. FRANGIBLE - SAW CUT into 5'x5' max. SECTIONS - refer 2° to plans for cut locations ,�: EXPANSION JOINT n E per contractor 4" frangible SLAB VAPOR BARRIER t 7K.8_ clean termite treated granular fill N -� E € VAPORARRIf I clean termite treated granular 41J 20" x 24" deep FOOTING w/ (3) #5's CONT. (top * bottom) * #3 STIRRUPS STANDARD @ I G" O.C. - TYPICAL at ALL SHEAR �__ I HOOK WALLS * ELEVATOR WALLS f ; ` .-,,,,,,,,,,,,,,,,, 20- ...........,,, -� TYPICAL AUGER CAST PILE 3" MIN. PILE EMBEDMENT REFER TO DETAILS I G" SHEAR WALL FOOTING @ TRAN51TIO SCALE: 3/4" = 1'-0" NF8 CONCRETE TIE BEAM E E ADDITIONAL 1 #5 O — �-- -� — (1) 24"x24"x#5 .::..... � _ � .,�.�.., � 12 0 C CORNER each side m. COMPOSITE LINTEL I 4 MIN ,LAP C E N ..�.._.,.,........S ... w/ (1) #5 ,_,,. __.,,._,,,,,.,,,_,,,.,,_ 90" 411 MIN _ ? ,,,..,.., '. max. A.,..------ #5 VERT. IN FILLED I E I I # VERT INFILLED- CELL1 1`" 5 _ �............... L... ...A. COLUMN (typ.) ? € ? E_.,_.. �- 0 P EN FOR CELL COLUMN (typ ') W I I WINDOW -� I I "_ "_,__ "„_, - NDOW OPENING i I 1 E ` "DEMONSTRATED ................. Y -E OOR OPENING IS MASONRY ROUGH SIMILAR (no sill, etc.) ..... OPENING - REFRTO.,,...................... A R C H I TECTU R ALS _....................._,W,. ANGIBLE FOOTER NOTE: POUR SOLID 8" CHEEP I = r p.) w/ (2) #5'5 (MIN) ® EACH WINDOW SILL ? I FORM -POUR 8'x8" min. PRECAST CAST-CRgTE SILLS CONCRETE CONCRETE SILL w/ (1) #5 MAY BE USED ­IN ttEU OF "" ...,I,,,,, I (" BLOCK WALL or j' TYPICAL C.M.U. POURED ILL I PRECAST CAST-CRETE "" T MASON Y WALL .,Y, SILL (or equal) I E i 1 FINAL K15ER/a i i FOOTING ( I E E r w/ (2) #5's top, center, ;._... ),�,,,..<.........,,._.. _W..,......._ __....... bottom - refer to details EXISTING LAP VERT. - STANDARD HOOK A MINIMUM OF I j ? LAP VERT STEEL & 48 BAR DIAVE.TAR.S....:..............L...L.......................,.. ..........................__... L....................., 411 MINIMUM a STANDARD HOOK A E BAR *-:z 4" MIN E M 0 F 48 " E E,... DIAMETERS"min.) t„ (30 ..... ,..�,...�................ y E i 1 MONOLITHIC FOUNDATION J_ FOUNDATION or — _ CONCRETE BEAM (below) nF ENING WINDOWE SC/- LE: NOT TO SCAAE i� n� CCU • p..i O ct � O N U � � 0 7 Q e PPOJECT NO. 16-039 S-10 B -- e o., -�:--> rq P r\i �f 1st F oor a n e r-, <E--1 o w n e 1-1 UL\, 2 b FOR CONSSTANCY 1MTH STRUCTURAL DESIGN SC TT B. WG U I RE + P. E. FL REG. #3953 DT I 45# Tile Loading 12 Reef Pitch 4, TYPICAL TRUSS END ALL BEAMS BY OTHERS UNLESS NOTED ON LAYOUT. BEARING HEIGHTS i ----------------- NOTE IT IS THE RESPONSIBILITY CIF THE BUILDING UES1GNER DR ARCHITECI TD PROVIPC AN APPR❑PRIATE CaNNECTION FOR TRUSSES 70 S UPPDR7 9 NG Tk'UCT L1RE PER REACTI❑NS SHOWN` ON TRUSS ENGINEEPING. SPECIAL C❑NSIDER'ATI❑NS FOR MECHANICAL EQUIPMENT AND/OR PLUMBING <AND THEIR CONNECTION IN TRUSS ''PACE MUST BE DIAGRAMMED BY BUILDER ❑N APPROVED TRUSS LAB 667 PRIOR TO FABRICATION, THIS COMPANY IS A TRUSS MANUFACTURER WHOSE RE PDNSII3ILITIES: ARE LIMITED TO THOSE DESCPIBEB IN WTCA 7-1995 'DESNI N RESPONhI IRILITIES'- ACCORDINGLY, IT D13C'LAIMS ANY RESPONSJDILITIE^ AND/OR LIABILITY FOR THE C-UNSTRUCTIDN DESIGN, DRAWINGS, DOCUMENTS INCLUDING THE INSTALLATI❑N AND BRACING OF TRUSSES MANUFACTURED BY THIS COMPANY, \A/T R, N I N CONVENTIONAL FRAMING, ERECTION AND/OR PERMANENT DRACINE IS NOT THE RESPONSIBILITY OF THE TRUSS DESIGNER, PLATE MANUFACTURER, OR TRUSS MANUFACTURER, PERSONS ERECTING TRUSSES ARE CAUTIONED TD SEED PROFESSIONAL ADVICE REGARDING EREC-TION BRACING WHICH IS ALWAYS REQUIRED TO PREVENT TDPPLING AND DOMINOING DUR1NC ERECTI❑ICI; AND P RMANENT BRACING 'WHICH MAY BE REQUIRED IN SP C:IEiC APPLICATIDN . SEE 'G111DI:; TO FjD DD PRACTICE FUR HANDLING, INSTALLING, RESTRAINING Px BRACING OF METAL PLATE IONNEIrTED WOOD TRUSSES RECLIMh'€ENDATIONS` (BCSI 2006) FOR FURTHER I'NFORMATI❑N, TRUSSCS SHALL BE INSTALLED IN A STRAIGHT AND PLUMB POSITION, WHERE NO SHEATHING IS APPLIED DIRECTLY TO TOP 3 ACID/DR BOTTOM CH❑RDS, THEY SHALL BE BRACED AS SPECIFIED DPI THE ENGINEERED DESIGN, TRUSSES SMALL BE HANDLED WITH s REASONABLE CARE DURING ERECTION TO PREVENT DAMAGE OR PERSDNAL INJURY. ATTENTICIN APPPDVAL DE THIS TRUSS LAYOUT I NECESSARY BEFORE EA IC:ATION CAN BEGIN, VERIFY SPANS, PITCHES, OVERHANGS, GS, HEELS AND BEARING CONDITIONS. AC C[PTANCE FJF THIS LAYDUT ASSUMES TOTAL RESPONSIBILITY. TRUSSES WILL BE BUILT PER THIS LAYDUT, ROOF TRUSSES FLOOR TRUSSES Y Y Y JL i 407- 3 1-14401386- 872— 50 98 f 352- 557- 4901 LUNG OUP / LIRMUN BEACH / f AS DTTE Customer Y Phoenl:-: ReaAy Homes e Iric, LOT/BLK/SUBDIV Lot I Diamond Sards SCALE DATE DRAWN BY M JDB NUMBER evlsi-0r Date(s) - in /i g /lc.. FT T HJ> F PFP I AYFIIJT ANIT) F 1f iTNFi-- IN F, THAT , FFTI iPANY THE TRU FS A T TTI T '7 RY