Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
I I 1 Manual S Compliance Report Job: LotlDiamondSands Date: 10/412016 - ahul I By: FJF DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL32771 Phone: 407-831-2665 Fax 407-333-3853 Vft: WWW.DEL-AIR.COM For: Phoenix Realty Homes Design Conditions Outdoor design DB: 90.5°F Sensible gain: 19208 Btuh Entering coil DB: 76.1°F Outdoor design WB: 77.8OF Latent gain: 1804 Btuh Entering coil WB: 63.2°F Indoor design DB: 75.0°F Total gain: 21012 Btuh Indoor RH: 50% Estimated airflow: 807 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: trane Model: 4TWR6024H1+TEM6AOB24H21++TDR Actual airflow: 807 cfm Sensible capacity: 20347 Btuh 106% of load Latent capacity: 2639 Btuh 146% of load Total capacity: 22986 Btuh 109% of load SHR: 89% Design Conditions Outdoor design DB: 43.0°F Heat loss: 16555 Btuh Entering coil DB: 68.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: trane Model: 4TWR6024H1+TEM6AOB24H21++TDR Actual airflow: 807 cfm Output capacity: 22602 Btuh 137% of load Capacity balance: 36 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 807 cfm Output capacity: 4.6 kW 95% of load Temp. rise: 50 OF The above equipment was selected in accordance with ACCA Manual S. f�l[°It' 2 -0 19 E'�li� Right -Suite® Universal 2017 17.0.03 RSU24019 e 1 ATK ..traction)lLotlDiamondSandsILotlDiamondSands.rup Calc=MJB Housefaces: W W �,� �� :� , kodfi tAms, 9 Manual S Compliance Report ahu2 DEL -AIR HEATING & AIR CONDITIONING Job: Date: By: LotlDiamondSands 10/4/2016 FJF 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-3853 Mb: WWW.DEL-AIR.COM For: 61 Phoenix Realty Homes Design Conditions Outdoor design DB: 90.5'F Sensible gain: 45502 Btuh Outdoor design WB: 77.8OF Latent gain: 5429 Btuh Indoor design DB: 75.0°F Total gain: 50931 Btuh Indoor RH: 50% Estimated airflow: 1833 cfm ' Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Trane Model: 4TWR6060H1+TEM6AOD6OH51++TDR Actual airflow: 1833 cfm Sensible capacity: 46448 Btuh 102% of load Latent capacity: 8910 Btuh 164% of load Total capacity: 55358 Btuh 109% of load SHR: 84% Design Conditions Outdoor design DB: 43.0°F Heat loss: 35203 Btuh Indoor design DB: 70.0°F Entering coil DB: 75.5°F Entering coil WB: 63.2°F Entering coil DB: 69.4'F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Trane Model: 4TWR606OH1+TEM6AOD6OH51++TDR Actual airflow: 1833 cfm Output capacity: 54259 Btuh 154% of load Capacity balance: 32 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1833 cfm Output capacity: 11.5 kW 112% of load Temp. rise: 50 OF The above equipment was selected in accordance with ACCA Manual S. � � 2016-Dec-02 09:e Tr 2 Right -Suite® Universal 2017 17.0.03 RSU24019 Page ...truction)1LotlDiamondSandslLotlDiamondSands.rup Calc = MJ8 House feces: W �r a Manual S Compliance Report Job: LotlDiamondSands Date: 10/412016 ahu3 By: FJF DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-3853 Wab: WWW.DEL-AIR.COM Project• • For: Phoenix Realty Homes Cooling Equipment Design Conditions Outdoor design DB: 90.5°F Sensible gain: 40561 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.8'F Latent gain: 8236 Btuh Entering coil WB: 63.7°F - Indoor design DB: 75.0°F Total gain: 48796 Btuh Indoor RH: 50% Estimated airflow: 1833 cfm ' Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Trane Model: 4TWR606OH1+TEM6AOD6OH51++TDR Actual airflow: 1833 cfm Sensible capacity: 45113 Btuh 111% of load Latent capacity: 10755 Btuh 131% of load Total capacity: 55868 Btuh 114% of load SHR: 81% Design Conditions Outdoor design DB: 43.0°F Heat loss: 39293 Btuh Entering coil DB: 68.9°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASH Manufacturer: Trane Model: 4TWR6060H1+TEM6AOD6OH51++TDR Actual airflow: 1833 cfm Output capacity: 54374 Btuh 138% of load Capacity balance: 34 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1833 cfm Output capacity: 5.6 kW 49% of load Temp. rise: 50 OF The above equipment was selected in accordance with ACCA Manual S. W 2016-Dec-02 09:e 3 rVhftoft Right -Suite® Universal 2017 17.0.03 RSU24019 Page 3 ...traction)\LotlDiamondSands%LotlDiamondSands.rup Calc=MJ8 Housefaces: W v Component Constructions Job: LotlDiamondSands Date: 10/4/2016 .D..�e� Wi Entire House By: FJF DEL AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-U53 Web: WWW.DEL-AIR.COM Project• • For: Phoenix Realty Homes - Design Conditions Location: Indoor: Heating Cooling Vero Beach Muni, FL, US Indoor temperature (T) 70 75 Elevation: 30 ft Design TD (T) 27 16 Latitude: 280N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.1 59.4 Dry bulb ('F) 43 91 Infiltration: Daily range (°F) - 15 (,L ) Method Simplified - Wet bulb (°F) - 78 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain itBtuhlft'-°F fY-°F/BWh Btuhff Btu Btuhffl Btuh Walls 13A-2ocs: Blk wall, stucco ext, r-2 ext bd ins, 8" thk, 1/2" gypsum board i nt fish Partitions 12C-Osw: Frm wall, r-13 cav ins, 1/2" gypsum board int fish, 2"x4" wood frm, 16" o.c. stud n 1055 0.201 0 5.43 5727 4.06 4285 e 735 0.201 0 5.43 3986 4.06 2982 s 1424 0.201 0 5.43 7728 4.06 5782 w 1038 0.201 0 5.43 5635 4.06 4216 all 4252 0.201 0 5.43 23077 4.06 17265 559 0.091 13.0 2.46 1374 1.31 733 Windows 2A 2ov: 2 glazing, cir outr, air gas, vnl frm mat, cir low-e innr, 1/4" gap, n 1/8" thk; NFRC rated (SHGC=0.45); 50% drapes, medium; 2 ft s overhang (6 ft window ht, 1.17 ft sep.); 6.67 ft head ht s w all 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, n 1/8" thk; NFRC rated (SHGC=0.52); 2 ft overhang (1.5 ft window ht, 5.67 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, cir outr, air gas, vni frm mat, clr low-e innr, 1/4" gap, n 1/8" thk; NFRC rated (SHGC=0.47); 50% drapes, medium; 2 ft e overhang (3 it window ht, 0.83 ft sep.); 6.67 ft head ht all 2A-2ovd: 2 glazing, clr outr, air gas, vni frm mat, cir low-e innr, 114' n gap, 1/8" thk; NFRC rated (SHGC=0.46); 15.67 ft overhang (10 ft window ht, 1 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, cir low-e innr, 1/4" gap, e 1/8" thk; NFRC rated (SHGC=0.47); 50% drapes, medium; 2 ft overhang (3 ft window ht, 2 ft sep.); 6.67 ft head ht 2A-2ovd: 2 glazing, cir outr, air gas, vnl frm mat, clr low-e innr, 1/4" e gap, 1/8" thk; NFRC rated (SHGC=0.46); 9.5 ft overhang (8 ft window ht, 0.33 It sep.); 6.67 ft head ht 2A-2ovd: 2 glazing, cir outr, air gas, vnl frm mat, cir low-e innr, 1/4" e gap, 1/8" thk; NFRC rated (SHGC=0.46); 2 ft overhang (10 ft window ht, 0.17 ft sep.); 6.67 ft head ht 30 0.760 0 20.5 616 18.2 545 12 0.760 0 20.5 246 18.2 218 28 0.760 0 20.5 575 18.2 509 30 0.760 0 20.5 616 43.2 1296 100 0.760 0 20.5 2052 25.7 2568 15 0.960 0 25.9 389 25.8 387 9 1.030 0 27.8 250 22.4 201 9 1.030 0 27.8 250 42.1 379 18 1.030 0 27.8 501 32.2 580 60 1.030 0 27.8 1669 25.6 1537 9 1.030 0 27.8 250 49.7 447 160 1.030 0 27.8 4450 27.5 4405 120 1.030 0 27.8 3337 55.0 6602 2016-Dec-02 09:01:19 Right -Suite® Universal 2017 17.0.03 RSU24019 Page 1 ...traction)\LotlDiamondSands%LotlDiamondSands.rup Calc=MJ8 Housefaces: W 2A-2ovd: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" a 200 1.030 gap, 1/8" thk; NFRC rated (SHGC=0.46); 2 ft overhang (10 ft window ht, 11.67 ft sep.); 6.67 ft head ht 2A-2ovd: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" a 70 1.030 gap, 1/8" thk; NFRC rated (SHGC=0.46); 18.67 ft overhang (10 ft e 80 1.030 window ht, 1 ft sep.); 6.67 ft head ht all 150 1.030 1OC-v: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, s 27 1.030 1/8" thk; NFRC rated (SHGC=0.35); 15.67 ft overhang (10 ftwindow ht, 1 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, s 11 0.760 1/8" thk; NFRC rated (SHGC=0.45); 50% drapes, medium; 2 ft overhang (4.5 ft window ht, 0.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, s 4 0.960 1/8" thk; NFRC rated (SHGC=0.52); 2 ft overhang (2 ft window ht, 1.83 w 4 0.960 ft sep.); 6.67 ft head ht all 8 0.960 1OC-v: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 27 1.030 1/8" thk; NFRC rated (SHGC=0.35); 8.33 ft overhang (9 ftwindow ht, 0.33 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 10 0.760 1/8" thk; NFRC rated (SHGC=0.45); 50% drapes, medium; 2 ft overhang (5 ft window ht, 1.17 ft sep.); 6.67 ft head ht 2A 2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 10 0.760 1/8" thk; NFRC rated (SHGC=0.45); 50% drapes, medium; 2 ft overhang (5 ft window ht, 12.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 41 0.760 1/8" thk; NFRC rated (SHGC=0.45); 50% drapes, medium; 2 ft overhang (5.5 ft window ht, 1.17 ft sep.); 6.67 ft head ht 2A 2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 22 0.760 1/8" thk; NFRC rated (SHGC=0.45); 50% drapes, medium; 2 ft overhang (5.5 ft window ht, 1.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 28 0.760 1/8" thk; NFRC rated (SHGC=0.45); 50%. drapes, medium; 4.83 ft overhang (5.5 ft window ht, 1.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 43 0.760 1/8" thk; NFRC rated (SHGC=0.45); 50% drapes, medium; 2 ft overhang (8 ft window ht, 0.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 9 0.960 1/8" thk; NFRC rated (SHGC=0.52); 2 ft overhang (4.5 ft window ht, 0.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1X' gap, w 45 0.960 1/8" thk; NFRC rated (SHGC=0.52); 2 ft overhang (5 ft window ht, 0.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 21 0.960 1/8" thk; NFRC rated (SHGC=0.52); 2 ft overhang (8 ftwindow ht, 0.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 53 0.960 1/8" thk; NFRC rated (SHGC=0.52); 8.33 ft overhang (9 ftwindow ht, 0.33 ft sep.); 6.67 ft head ht 2A-2ovd: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 114' w 72 1.030 gap, 1/8" thk; NFRC rated (SHGC=0.46); 2 ft overhang (9 ft window ht, 12.83 ft sep.); 6.67 ft head ht 2A-2ovd: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" w 99 1.030 gap, 1/8" thk; NFRC rated (SHGC=0.46); 2 ft overhang (11 ft window ht, 10 ft sep.); 6.67 ft head ht Doors 11 DO: Door, wd sc type n 21 0.390 Ceilings 0 27.8 5562 60.2 12033 0 27.8 1947 25.6 1793 0 27.8 2225 25.6 2049 0 27.8 4172 25.6 3841 0 27.8 742 16.3 435 0 20.5 231 18.2 204 0 25.9 104 25.8 103 0 25.9 104 64.8 259 0 25.9 207 45.3 363 0 27.8 751 21.3 574 0 20.5 205 42.8 428 0 20.5 205 45.4 454 0 20.5 846 43.0 1774 0 20.5 451 45.4 1000 0 20.5 564 34.6 952 0 20.5 876 42.6 1818 0 25.9 233 57.6 519 0 25.9 1166 58.4 2626 0 25.9 553 60.8 1297 0 25.9 1361 36.3 1904 0 27.8 2002 60.2 4332 0 0 16X19-Omd: Attic ceiling, mtl roof mat, r-20 roof ins, 1/2" gypsum board 2953 0.408 19.0 int fish Floors 20P-13t: Fir floor, frm fir, 12" thkns, r-13 cav ins, amb ovr 62 0.068 13.0 68 0.068 13.0 all 130 0.068 13.0 W Oft Right -Suite® Universal2017 17.0.03 RSU24019 ...truction)1LotlDiamondSands%LotlDiamondSands.rup Calc=MJ8 Housefaces: W 27.8 2753 60.2 5957 10.5 225 11.4 244 1.53 4514 1.50 4444 1.84 114 0.87 54 1.84 125 0.87 59 1.84 239 0.87 113 2016-Dec-02 09:01:19 Page 2 20P-13t: Fir floor, frm fir, 12" thkns, r-13 cav ins, gar ovr 22A-tpl: Bg floor, light dry soil, on grade depth 1532 0.068 13.0 1.84 2812 0.87 1333 121 0.989 0 26.7 3218 0 0 2016-Dec-02 09:01:19 wrkhftgft Right -Suite® Universal 2017 17.0.03 RSU24019 Page 3 ... truction)\LotlDiem ondSands\LotlDism ondSands.rup Calc = MJ8 House faces: W Ciom onent Constructions Job: Lot1DiamondSands ahu1p Byte: FJF/2016 DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-3853 Web: WWW.DEL-AIR.COM _ For: Phoenix Realty Homes ' Design Conditions Location: Indoor: Heating Cooling Vero Beach Muni, FL, US Indoor temperature (T) 70 75 ' Elevation: 30 ft Design TD (°F) 27 16 Latitude: 28°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.1 59.4 Dry bulb (T) 43 91 Infiltration: Daily range (7) ' - 15 (L ) Method Simplified Wet bulb (T) - 78 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain f, BWh/ft'--"F W-01`/9Wh MUM' Btuh Btuh/fF BWh Walls 13A-2ocs: Blk wall, stucco ext, r-2 ext bd ins, 8" thk, 1/2" gypsum n 63 0.201 0 5.43 342 4.06 256 board intfnsh a 212 0.201 0 5.43 1148 4.06 859 s 428 0.201 0 5.43 2320 4.06 1736 w 254 0.201 0 5.43 1376 4.06 1029 all 956 0.201 0 5.43 5185 4.06 3880 Partitions 12C-Osw: Frm wall, r-13 cav ins. 1/2" gvpsum board int fish. 2"x4" 559 0.091 13.0 2.46 1374 1.31 733 wood frm, 16" o.c. stud Windows IOC-v: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 27 1.030 1/8" thk; NFRC rated (SHGC=0.35); 8.33 ft overhang (9 ft window ht, 0.33 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 22 0.760 1/8" thk; NFRC rated (SHGC=0.45); 50% drapes, medium; 2 ft overhang (5.5 ft window ht, 1.83 It sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 28 0.760 1/8" thk; NFRC rated (SHGC=0.45); 50% drapes, medium; 4.83 It overhang (5.5 ft window ht, 1.83 ft sep.); 6.67 ft head ht 2A 2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 53 0.960 1/8" thk; NFRC rated (SHGC=0.52); 8.33 ft overhang (9 ft window ht, 0.33 ft sep.); 6.67 ft head ht Doors 11 DO: Door, wd sc type n 21 0.390 Ceilings (none) Floors 22A-tpl: Bg floor, light dry soil, on grade depth 121 0.989 W. rk 9 ` Right -Suite® Universal2017 17.0.03 RSU24019 ..traction)%LotlDiamondSandslLotlDiamondSands.rup Calc=MJS Housefaces: W 0 27.8 751 21.3 574 0 20.5 451 45.4 1000 0 20.5 564 34.6 952 0 25.9 1361 36.3 1904 0 10.5 225 11.4 244 0 26.7 3218 0 0 2016-Dec-02 09:01:19 Page 4 J J 2016-Dec-02 09:01:19 W�°}g�� Right -Suite® Universal 17.0.03 RSU24019 Page 9 traction)lLotlDiamondSandslLotlDiamondSands.rup Calc=MJ6 Housefaces: W RJob:�. �; ! r;,DE �`"iSe Component Constructions ''UZZa ahu2 DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-3853 Mb: WWW.DEL-AIR.COM LotlDiamondSands Date: 10/4/2016 By: FJF Project• • For: Phoenix Realty Homes - Design Conditions Location: Indoor: Heating Cooling Vero Beach Muni, FL, US Indoor temperature (T) 70 75 - Elevation: 30 ft Design TD (°F) 27 16 Latitude: 280N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.1 59.4 Dry bulb (T) 43 91 Infiltration: Daily range (T) - 15 (L ) Method Simplified " Wet bulb (T) - 78 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions or Area U-value Insul R Htg HTM Loss Clg HTM Gain fF Btuh/fP--°F fF-°F/Btuh Btuh/ft' Btuh Btuhfft' Btu Walls 13A-2ocs: Blk wall, stucco ext, r-2 ext bd ins, 8" thk, 1/2" gypsum n 494 0.201 0 5.43 2678 4.06 2004 board intfnsh a 156 0.201 0 5.43 844 4.06 631 s 141 0.201 0 5.43 767 4.06 574 w 259 0.201 0 5.43 1407 4.06 1053 all 1050 0.201 0 5.43 5696 4.06 4262 Partitions (none) Windows 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, n 30 1/8" thk; NFRC rated (SHGC=0.45); 50% drapes, medium; 2 ft overhang (6 ft window ht, 1.17 It sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 114' gap, n 15 1/8" thk; NFRC rated (SHGC=0.52); 2 ft overhang (1.5 ft window ht, 5.67 ft sep.); 6.67 ft head ht 2A-2ovd: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 114' n 60 gap, 1/8" thk; NFRC rated (SHGC=0.46); 15.67 It overhang (10 It window ht, 1 ft sep.); 6.67 ft head ht 2A-2ovd: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 114' a 200 gap, 1/8" thk; NFRC rated (SHGC=0.46); 2 ft overhang (10 ft window ht, 11.67 ft sep.); 6.67 ft head ht 2A-2ovd: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 114' a 70 gap, 1/8" thk; NFRC rated (SHGC=0.46); 18.67 ft overhang (10 ft e 80 window ht, 1 ft sep.); 6.67 ft head ht all 150 10C-v: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, s 27 1/8" thk; NFRC rated (SHGC=0.35); 15.67 ft overhang (10 ftwindow ht, 1 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 41 1/8" thk; NFRC rated (SHGC=0.45); 50% drapes, medium; 2 ft overhang (5.5 ft window ht, 1.17 ft sep.); 6.67 ft head ht 2A-2ovd: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" w 72 gap, 1/8" thk; NFRC rated (SHGC=0.46); 2 ft overhang (9 ft window ht, 12.83 ft sep.); 6.67 ft head ht w a w Right -Suite® Universal2017 17.0.03 RSU24019 ...traction)%LotlDiamondSands%LotlDiamondSands.rup Calc=MJ8 Housefaces: W 0.760 0 20.5 616 18.2 545 0.960 0 25.9 389 25.8 387 1.030 0 27.8 1669 25.6 1537 1.030 0 27.8 5562 60.2 12033 1.030 0 27.8 1947 25.6 1793 1.030 0 27.8 2225 25.6 2049 1.030 0 27.8 4172 25.6 3841 1.030 0 27.8 742 16.3 435 0.760 0 20.5 846 43.0 1774 1.030 0 27.8 2002 60.2 4332 2016-Dec-02 09:01:19 Page 6 2A-2ovd: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" w 99 1.030 0 27.8 2753 60.2 5957 gap, 1/8" thk; NFRC rated (SHGC=0.46); 2 ft overhang (11 ftwindow ht, 10 ft sep.); 6.67 ft head ht Doors (none) Ceilings 16X19-Omd: Attic ceiling, mtl roof mat, r-20 roof ins, 1/2" gypsum board 775 0.408 19.0 1.53 1184 1.50 1166 int fish Floors 2013-13t: Fir floor, frm fir, 12" thkns, r-13 cav ins, amb ovr 29 0.068 13.0 1.84 52 0.87 25 2013-13t: Fir floor, frm fir, 12" thkns, r-13 cav ins, gar ovr 1478 0.068 13.0 1.84 2714 0.87 1286 may. 2016-Dec-02 09:01:19 Wr%htVW Right -Suite® Universal2017 17.0.03 RSU24019 Page 7 ...traction)lLotlDiamondSands\LotlDiamondSands.rup Calc = MJS House faces: W Component Constructions Job: Lot1DiamondSands ���,,,,*•�� p Date: 10/4l2016 ahu3 By: FJF DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-3853 Wdb: WWW.DEL-AIR.COM _ For: Phoenix Realty Homes Location: Indoor: Heating Cooling Vero Beach Muni, FL, US Indoor temperature (T) 70 75 Elevation: 30 ft Design TD (T) 27 16 Latitude: 28°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.1 59.4 Dry bulb (T) 43 91 Infiltration: Daily range (T) - 15 ( L ) Method Simplified Wet bulb (T) - 78 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Walls 13A-2ocs: Blk wall, stucco ext, r-2 ext bd ins, 8" thk, 1/2" gypsum board i nt fish Or Area U-value Insul R Htg HTM Loss Clg HTM Gain tP Btuh/tt'-°F tP-°F/Btuh Btuh/IF Btu Btuh/fP Btuh n 499 0.201 0 5.43 2707 4.06 2025 e 368 0.201 0 5.43 1994 4.06 1492 s 855 0.201 0 5.43 4641 4.06 3472 w 526 0.201 0 5.43 2852 4.06 2134 all 2247 0.201 0 5.43 12195 4.06 9124 Partitions (none) Windows 2A 2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, s 1/8" thk; NFRC rated (SHGC=0.45); 50% drapes, medium; 2 ft s overhang (6 ft window ht, 1.17 ft sep.); 6.67 ft head ht w all 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, n 1/8" thk; NFRC rated (SHGC=0.47); 50% drapes, medium; 2 ft e overhang (3 it window ht, 0.83 It sep.); 6.67 ft head ht all 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, e 1/8" thk; NFRC rated (SHGC=0.47); 50% drapes, medium; 2 ft overhang (3 ft window ht, 2 ft sep.); 6.67 ft head ht 2A-2ovd: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" e gap, 1/8" thk; NFRC rated (SHGC=0.46); 9.5 ft overhang (8 ft window ht, 0.33 ft sep.); 6.67 ft head ht 2A-2ovd: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" e gap, 1/8" thk; NFRC rated (SHGC=0.46); 2 ft overhang (10 ft window ht, 0.17 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, s 1/8" thk; NFRC rated (SHGC=0.45); 50% drapes, medium; 2 ft overhang (4.5 ft window ht, 0.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, s 1/8" thk; NFRC rated (SHGC=0.52); 2 ft overhang (2 ftwindow ht, 1.83 w ft sep.); 6.67 ft head ht all 12 0.760 0 20.5 246 18.2 218 28 0.760 0 20.5 575 18.2 509 30 0.760 0 20.5 616 43.2 1296 70 0.760 0 20.5 1436 28.9 2023 9 1.030 0 27.8 250 22.4 201 9 1.030 0 27.8 250 42.1 379 18 1.030 0 27.8 501 32.2 580 9 1.030 0 27.8 250 49.7 447 160 1.030 0 27.8 4450 27.5 4405 120 1.030 0 27.8 3337 55.0 6602 11 0.760 0 20.5 231 18.2 204 4 0.960 0 25.9 104 25.8 103 4 0.960 0 25.9 104 64.8 259 8 0.960 0 25.9 207 45.3 363 2016-Dec-02 09:01:19 WdghtKOW Right-Suite(D Universal 2017 17.0.03 RSU24019 Page 8 truction)\LotlDiamondSands\LotlDiamond5ands.rup Calc=MJ8 Housefaces: W 2A 2ov: 2 glazing, cir outr, air gas, vnl frm mat, cir low-e innr, 1/4" gap, w 10 0.760 0 1/8" thk; NFRC rated (SHGC=0.45); 50% drapes, medium; 2 ft overhang (5 ft window ht, 1.17 ft sep.); 6.67 ft head ht ' 2A-2ov: 2 glazing, cir outr, air gas, vnl frm mat, cir low-e innr, 1/4" gap, w 10 0.760 0 y 1/8" thk; NFRC rated (SHGC=0.45); 50% drapes, medium; 2 ft overhang (5 ft window ht, 12.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 43 0.760 0 ' 1/8" thk; NFRC rated (SHGC=0.45); 50% drapes, medium; 2 ft overhang (8 ft window ht, 0.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, cir outr, air gas, vnl frm mat, cir low-e innr, 1/4" gap, w 9 0.960 0 1/8" thk; NFRC rated (SHGC=0.52); 2 ft overhang (4.5 ft window ht, 0.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, cir outr, air gas, vni frm mat, clr low-e innr, 1/4" gap, w 45 0.960 0 1/8" thk; NFRC rated (SHGC=0.52); 2 ft overhang (5 ft window ht, 0.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, w 21 0.960 0 1/8" thk; NFRC rated (SHGC=0.52); 2 ft overhang (8 ftwindow ht, 0.83 ft sep.); 6.67 ft head ht - Doors (none) Ceilings 16X19-Omd: Attic ceiling, mtl roof mat, r-20 roof ins, 1/2" gypsum board 2178 0.408 19.0 int fish Floors 20P-13t: Fir floor, frm fir, 12" thkns, r-13 cav ins, amb ovr 34 0.068 13.0 68 0.068 13.0 all 102 0.068 13.0 20P-13t: Fir floor, frm fir, 12" thkns, r-13 cav ins, gar ovr 54 0.068 13.0 20.5 205 42.8 428 20.5 205 45.4 454 20.5 876 42.6 1818 25.9 233 57.6 519 25.9 1166 58.4 2626 25.9 553 60.8 1297 1.53 3330 1.50 3278 1.84 62 0.87 29 1.84 125 0.87 59 1.84 187 0.87 89 1.84 99 0.87 47 ,. p.�i� 2016-Dec-02 09:01:19 WrIghva RightSuite® Universal 2017 17.0.03 RSU24019 Page 9 ►...traction)%LotlDiamondSands%LotlDiamondSands.rup Calc=MJ6 Housefaces: W �!'� ,�� Job: Lot1DiamondSands 14.�"'#`""�� Project Summary Date: 10/4/2016 11�!1k1�Glll Entire HOIISe By: FJF DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-3333853 Mb: WWW.DEL-AIR.COM Project• • For: Phoenix Realty Homes Notes: Design Information Weather: Vero Beach Muni, FL, US Winter Design Conditions Outside db 43 OF Inside db 70 OF Design TD 27 OF Heating Summary Structure 77995 Btuh Ducts 9972 Btuh Central vent (104 cfm) 3085 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 91052 Btuh Infiltration Method Simplified Construction quality Semi -tight Fireplaces 0 Heating Cooling Area (ft2 5012 5012 Volume (ft3) 56690 56690 Air changes/hour 0.25 0.13 Equiv. AVF (cfm) 236 123 Summer Design Conditions Outside db 91 OF Inside db 75 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 59 gr/lb Sensible Cooling Equipment Load Sizing Structure 92922 Btuh Ducts 8029 Btuh Central vent (104 cfm) 1771 Btuh Blower 0 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Equipment sensible load 102723 Btuh Latent Cooling Equipment Load Sizing Structure 5953 Btuh Ducts 5323 Btuh Central vent (104 cfm) 4194 Btuh Equipment latent load 11276 Btuh Equipment total load 113999 Btuh Req. total capacity at 0.70 SHR 12.2 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref. n/a Coil n/a AHRI ref. n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Universal 2017 17.0.03 RSU24019 2016-Dec-02 09:01:19 Right -Suite® Page 1 ...truction)\LotlDiamondSands\LotlDiamondSands.rup Calc = MJ8 House faces: W Pro ect Summaw Job: LotiDiamondSands DELI I ' s Date: 10/4/2016 = ` W�IdN � { plMlil6�iMf0 _ ahul By: FJF DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-3853 Mb: WWW.DEL-AIR.COM +Project Information For: Phoenix Realty Homes Notes: Design Information Weather: Vero Beach Muni, FL, US Winter Design Conditions Outside db 43 OF Inside db 70 OF Design TD 27 OF Heating Summary Structure 14484 Btuh Ducts 1448 Btuh Central vent (21 cfm) 623 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 16555 Btuh Infiltration Method Simplified Construction quality Semi -tight Fireplaces 0 Heating Cooling Area (ft2) 1286 1286 Volume (ft3) 11617 11617 Air changes/hour 0.24 0.12 Equiv. AVF (cfm) 46 24 Summer Design Conditions Outside db 91 OF Inside db 75 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 59 gr/lb Sensible Cooling Equipment Load Sizing Structure 17136 Btuh Ducts 1714 Btuh Central vent (21 cfm) 358 Btuh Blower 0 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Equipment sensible load 19208 Btuh Latent Cooling Equipment Load Sizing Structure 958 Btuh Ducts 0 Btuh Central vent (21 cfm) 847 Btuh Equipment latent load 1804 Btuh Equipment total load 21012 Btuh Req. total capacity at 0.80 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make trane Make trane Trade TRANE Trade TRANE Model 4TWR6024H1 Cond 4TWR6024H1 AHRI ref 7562095 Coil TEM6AOB24H21++TDR AHRI ref 7562095 Efficiency 9 HSPF Efficiency 13.0 EER, 16 SEER Heating input Sensible cooling 19360 Btuh Heating output 22000 Btuh @ 47°F Latent cooling 4840 Btuh Temperature rise 25 OF Total cooling 24200 Btuh Actual air flow 807 cfm Actual air flow 807 cfm Air flow factor 0.051 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0.38 in H2O Static pressure 0.38 in H2O Space thermostat Load sensible heat .ratio 0.91 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Dec-02 09:01:19 At--. WWrlgh"Oft Right -Suite® Universal 2017 17.0.03 RSU24019 Page 2 ATh ...truction)lLotlDiamondSands%LotlDiamondSands.rup Calc = MJ8 House faces: W DEA L-„� Project Summary «1►+a ahu2 DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD,.FL 32771 Phone: 407-831-2665 Fax 407-333-3853 Wab: WWW.DEL-AIR.COM For: Phoenix Realty Homes Notes: Weather: Vero Beach Muni, FL, US Winter Design Conditions Outside db 43 OF Inside db 70 OF Design TD 27 OF Heating Summary Structure 30574 Btuh Ducts 3887 Btuh Central vent (25 cfm) 742 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 35203 Btuh Infiltration Method Simplified Construction quality Semi -tight Fireplaces 0 Heating Cooling Area (ftz) 1717 1871 Volume (ft') 20472 20472 Air changes/hour 0.22 0.11 Equiv. AVF (cfm) 73 38 Job: Lot1DiamondSands Date: 10/4/2016 By: FJF Summer Design Conditions Outside db 91 OF Inside db 75 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 59 gr/lb Sensible Cooling Equipment Load Sizing Structure 41849 Btuh Ducts 3226 Btuh Central vent (25 cfm) 426 Btuh Blower 0 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Equipment sensible load 45502 Btuh Latent Cooling Equipment Load Sizing Structure 2339 Btuh Ducts 2082 Btuh Central vent (25 cfm) 1008 Btuh Equipment latent load 5429 Btuh Equipment total load 50931 Btuh Req. total capacity at 0.80 SHR 4.7 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade TRAN E Trade TRAN E Model 4TWR6060H1 Cond 4TWR606OH1 AHRI ref 7563852 Coil TEM6AOD6OH51++TDR AHRI ref 7563852 Efficiency 9 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 44000 Btuh Heating output 55000 Btuh @ 47°F Latent cooling 11000 Btuh Temperature rise 27 OF Total cooling 55000 Btuh Actual air flow 1833 cfm Actual air flow 1833 cfm Air flow factor 0.053 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0.25 in H2O Static pressure 0.25 in H2O Space thermostat Load sensible heat ratio 0.89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wE°fthts Right Universal 2017 17.0.03 RSU24019 2016-Dec-02'09:01:19 -Suite® Page 3 ...truction)\LotlDiamondSands\LotlDiamondSands.rup Calc = MJB House faces: W Project SummaryJob: LotiDiamondSands ,�++Date: 10/4/2016 IIr1IYMi$+>11�11ahu3 By: FJF DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-3853 Web: WWW.DEL-AIR.COM For: Phoenix Realty Homes Notes: Weather: Vero Beach Muni, FL, US Winter Design Conditions Outside db 43 °F Inside db 70 °F Design TD 27 °F Heating Summary Structure 32936 Btuh Ducts 4636 Btuh Central vent (58 cfm) 1721 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 39293 Btuh Infiltration Method Simplified Construction quality Semi -tight Fireplaces 0 Heating Cooling Area (ftZ) 2009 2397 Volume (ft3) 24601 24601 Air changes/hour 0.29 0.15 Equiv. AVF (cfm) 117 61 Summer Design Conditions Outside db 91 °F Inside db 75 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 59 gr/lb Sensible Cooling Equipment Load Sizing Structure 36281 Btuh Ducts 3292 Btuh Central vent (58 cfm) 988 Btuh Blower 0 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Equipment sensible load 40561 Btuh Latent Cooling Equipment Load Sizing Structure 2656 Btuh Ducts 3241 Btuh Central vent (58 cfm) 2339 Btuh Equipment latent load 8236 Btuh Equipment total load 48796 Btuh Req. total capacity at 0.75 SHR 4.5 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade TRANE Trade TRANE Model 4TWR606OH1 Cond 4TWR6060H1 AHRI ref 7563852 Coil TEM6AOD6OH51++TDR AHRI ref 7563852 Efficiency 9 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 41250 Btuh Heating output 55000 Btuh @ 47°F Latent cooling 13750 Btuh Temperature rise 27 °F Total cooling 55000 Btuh Actual air flow 1833 cfm Actual air flow 1833 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.25 in H2O Static pressure 0.25 in H2O Space thermostat Load sensible heat ratio. 0.83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Dec-02 09:01:19 Right -Suite® Universal 2017 17.0.03 RSU24019 Page 4 doM ..tructionjlLotlDiamondSandslLotlDiamondSands.rup Calc = MJB House faces: W -M Worksheet 9L Right Entire House DEL -AIR HEATING &AIR CONDITIONING 531 GODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-M53 Wsb: WWW.DEL-AIR.COM Job: LotlDlamondSancls Date: 101412016 By: FJF I Room name Entire House ahul 2 Exposed wall 555.5 ft 120.5 ft 3 Room height 10.2 ft 9.0 ft 4 Room dimensions 5 Room area 5559.0 W 1290.8 ft' Ty Construction U-value Or HTM Area (ft� Load Area (ft5 Load number (Btuh/W*F) (BtuhlftI I or perimeter (ft) (Bt h) I or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat cool 6 7n 7776 a" 77z9665 5727 4285 63 63 77777W -256 �-o b 766 -616 545 D "e 31 2 . ..... 09M "W, 25.92 �'O 0 M 387,," 25.70 RD' -V - ' ' , " , , , 5 -37"Ik' � -, " " , -2- 1 20o 1 -;2 630 n 7, 22.3 9 13A-2ocs 0.201 a 5.43 4.06 1383 735 3986 2982 212 212 1148 859 2A-2ov 1.030 a 27.81 42.11 9 2 250 379 0 0 0 0 --G 2A-2ov 1.030 a 27.81 49.66 9 0 250 447 0 0 0 0 --G 2A-2ovd 1.030 a 27.81 27.53 160 151 4450 4405 0 0 0 0 --G 2A-2ovd 1.030 a 27.81 55.02 120 18 3337 6W2 0 0 0 0 2A-2ovd 1.030 a 27.81 60.17 200 0 5562 12033 0 0 0 0 2A-2ovd 1.030 a 27.81 25.61 70 70 1947 1793 0 0 0 0 --G 2A-2ovd 1.030 a 27.81 25.61 SO so 2225 2049 0 0 0 0 '7014151 $:4 777�� �-7 14N4 - --T -6*2 77777?0 -7-T-426 20 1126 ---17-77777 C) -0 27, 0 0 --G: I oc-V _-_27 .42 435 - : - " 0 '204,�� :,0.760 -18 17,-'- -4 . �'o 0 t�o 12 '0 8- 246 2' 0.760 S'� 2 12 0 28 28 0760 ',s' 20'52 e-- I - 11 'A"I 0 ""��o - - 26.5 �'L---G o%LL 2AW6 L ��o �L� Q. 13A-2ocs 0.201 w 5.43 4.06 1552 1038 5635 4216 383 254 1376 1029 10C-V 1.030 w 27.81 21.25 27 20 751 574 27 20 751 574 2A-2ov 0.760 w 20.52 42.76 10 1 205 428 0 0 0 0 --G 2A-20v 0.760 w 20.52 45.43 10 0 205 454 0 0 0 0 ---G 2A-2ov 0.760 w 20.52 43.01 41 4 846 1774 0 0 0 0 --G 2A-2ov 0.760 w 20.52 45.43 22 0 451 1000 22 0 451 1000 --G 2A-2ov 0.760 w 20.52 34.63 28 11 564 952 28 11 564 952 2A-2ov 0.760 w 20.52 43.21 30 2 616 1296 0 0 0 0 --G 2A-2ov 0.760 w 20.52 42.61 43 4 876 1818 0 0 0 0 2A-2ov 0.960 w 25.92 64.85 4 0 104 259 0 0 0 0 2A-2ov 0.960 w 25.92 57.64 9 2 233 519 0 0 0 0 A 2A-2ov 0.960 w 25.92 58.36 45 7 1166 2626 0 0 0 0 --G 2A-2ov 0.960 w 25.92 60.79 21 2 553 1297 0 0 0 0 --G 2A-2ov 0.960 w 25.92 36.27 53 38 1361 1904 53 38 1361 19134 G 2A-2ovd 1.030 w 27.81 60.17 72 0 2002 4332 0 0 0 0 G 2A-2ovd 1.030 w 27.81 60.17 99 0 2753 5957 0 0 0 0 -559 13 4 L L`.AE,6 "22'5 244 21. , --21 .�,1-225 c 16X19-ftd 0.408 1.53 1.50 2953 2953 4514 4444 0 0 0 0 . .. . ...... , 77 20P2 ==bm =AX =j1V ==% 7, _ _ '-- _.5!t =,0'. F 20P-13t 0.0613 1.84 0.87 68 68 125 59 0 0 0 0 ,P- .2Op:fi I 11TIUZ:' =11E I I =-- - , =71.44 F 2�26- 0.00 0.989 26.70 1291 121 3218 0 1291 121 3218 0 77 777-= 6 c) AED excursion 1611 3846 Envelope loss/gain 70987 82780 13129 13132 12 a) Infiltration 7008 2D92 1355 404 b) Room ventilation 0 0 0 0 13 1 ntemal gains: Occupants @ 230 5 11501 0 0 Appliances/other 69M 3600 Subtotal (lines 6 to 13) 77995 92922 14484 17136 Less external load 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 77995 92922 14484 7136 9% 9972 8029 10% 10% 1448 1714 15 Duct loads 13% 01 Less transfer 0 0 0 Total man load 879671 1009521 15932 183850 Air required (cfm) 4473 4473 807, .71 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -fj�- w0ghlootr 2016-Dec-02 09:01:19 AN% Right -Suite@ Universal 2017 17.0.03 RSU24019 Page I ... truction)lLotlDiamondSands%LotlDiamand8ands.rup Calc=MJB House faces: W J PeL Rig ht-JO Works heet Entire House DEL -AIR HEATING &AIR CONDITIONING 531 CODISCO WAY, SANFORD, Ft. 32771 Phone: 407-831-2665 Fax 407-333-3853 Web: WWW.DEL-AIR.COM Job: LotlDiamondSands Date: 1014/2016 By: FJF 1 Room name ahu2 ahu3 2 Exposed wall 162.0 ft 273.0 ft 3 Room height 10.9 ft 10.3 ft 4 Room dimensions 5 Room area 1871.3 ft2 2397.0 ft' Ty Construction U-value Or HTM Area (ft5 Load Area (ftj Load number (Btuhlftk'F) (Btuh/ft) or perimeter (ft) (Bt h) or perimeter (ft) (Btuh) I Heat Cool Gross N/P/s Heat Cool Gr.. N/P/S Heat Cool "'A 2025 6 1 �, , -'�,O-lm 7V 4177466 too �Z -5-�7NM 99 �'o cw� 0.960 5 2 5 6, 760 k�,20M '616 545 '26i 30 2 8 AV 7 389 0 % �2 �9 1030 o 0 a 0 9 13A-2ocs 0.201 a 5.43 4.06 506 156 844 631 666 368 1994 1492 2A-2ov 1.030 a 27.81 42.11 0 0 0 0 9 2 250 379 ---G 2A-2ov 1.030 a 27.81 49.66 0 0 0 0 9 0 250 447 2A-2ovd 1.030 a 27.81 27.53 0 0 0 0 160 151 4450 4405 --G 2A-2ovd 1.030 a 27.81 55.02 0 0 0 0 120 18 3337 6602 2A-2ovd 1.030 a 27.81 60.17 200 0 5562 12033 0 0 0 0 2A-2ovd 1.030 a 27.81 25.61 70 70 1947 1793 0 0 0 0 --Q 2A-2ovd 1.030 a 27.81 25.61 BO 80 2225 2049 0 0 0 0 7-s,,.-,, 9.1a 77i �J,67 7 7777 7,r Z4 % 41 --742 0 0 0 0 -27, 771S s, -"� '�" �""2t 436 811� 16,31 7 2A2ou 6760112052 1817 0 0, -0 �231 204 ��^ 2At2dVe 0:-7160 2662 ,�18-17 60 9 -,,20.52 �!'� 71 o " 12 12 246 218 "'o 28 " " 728 5 509 ',--- !LQ.W Ls- 'L�25,92 j5;7.8 ;..Lo -A -4 13A-2ocs 0.201 w 5.43 4.06 472 259 1407 1053 698 526 2852 2134 --G 10C-v 1.030 w 27.81 21.25 0 0 0 0 0 0 0 0 2A-2ov 0.760 w 20.52 42.76 0 0 0 0 10 1 205 428 --G 2A-2ov 0.760 w 20.52 45.43 0 0 0 0 10 0 205 454 2A-2ov 0.760 w 20.52 43.01 41 4 846 1774 0 0 0 0 --G 2A-2ov 0.760 w 20.52 45.43 0 0 0 0 0 0 0 0 --G 2A-2ov 0.760 w 20.52 34.63 0 0 a 0 0 0 0 0 G 2A-2ov 0.760 w 20.52 43.21 0 0 0 0 30 2 616 1296 --G 2A-2ov 0.760 w 20.52 42.61 0 0 0 0 43 4 876 1818 G 2A-2ov 0.960 w 25.92 64.85 0 0 0 0 4 0 104 259 G 2A-2ov 0.960 w 25.92 57.64 0 0 0 0 9 2 233 519 --G 2A-2ov 0.960 w 25.92 58.36 0 0 0 0 45 7 1166 2626 2A-2ov 0.960 w 25.92 60.79 0 0 0 0 21 2 553 1297 --G 2A-2ov 0.960 w 25.92 36.27 0 0 0 0 0 0 0 0 2A-2ovd 1.030 w 27.81 60.17 72 0 2002 4332 0 0 0 0 2A-2ovd 1.030 w 27.81 60.17 99 0 2753, 5957 0 0 0 0 !7 00 77=b -0 7 7� 7- Dd 1�0 6 -""-0b A -'�-o --o -L-0 C 16X19-0md 0.408 1.53 1.50 775 775 1184 1166 2178 2178 3330 3278 It -,:�734 347 F 2013-13t 0.068 1.84 0.87 0 0 0 0 68 68 125 59 �p �� � 111--=,01, ==RM �1 ._ 1286 5l �� ==-2-41. F 22A-tpl 0.989 26.70 0.00 0 0 0 0 0 0 0 0 =7 6 c) AED excursion 0 110 Envelope loss/gain 28396 37579 29462 34413 12 a) Infiftration 2178 650 3475 1037 b) Room ventilation 0 0 0 0 13 1 ntemal gains: Occupants @ 230 4 920 1 230 Appliances/other 27001 600 Subtotal (lines 6 to 13) 30574 41849 32936 36281 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 30574 41849 32936 36281 15 1 Duct loads 13%1 8%1 3887 3226 14% 9%1 4636 3292 Total mom load 344621 450761 37573 39573 Air required (cfm) 1833 1833 1 Im 1833_ Calculations approved bV ACCA to meet all requirements of Manual J 8th Ed. Vwr#g*"w0ft- 2016 -Dec-02 09:01:19 Right -Suite® Universal 2017 17.0.03 RSU24019 Page 2 IJ4- ... truction)\LotlDiamondSands%LotlDiamondSands.rup Calc=MJ8 Housefaces: W 9;. R7 r N v 0O m �' r v 55 L z n r2 Z Z g +n M �0 =r W a CD V C 1. 1- Right-JO Worksheet ahul DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-3853 Wab: WWW.DEL-AIR.COM Job: Lot1DiamondSands Date: 101412016 By: FJF Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 44#. wastighikataIr 2016-Dec-02 09:01:19 Aft Right -Suite® Universal 2017 17.0.03 RSU24019 Page 4 ...truction)lLotlDiamondSands\LotlDiamondSands.rup Calc = MJ8 House faces: W '� Right-J® Worksheet Job: LotlDiamondSands OX004M ahu2 Date: 10/4/2016 By: FJF DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-3853 Web: WWW.DEL-AIR.COM 1 Roan name ahu2 utility 2 Exposed wall 162.0 ft 16.5 ft 3 Roan height 10.9 ft 10.0 ft heat/cool 4 Roan dimensions 9.5 x 7.0 ft 5 Roan area 1871.3 ft2 66.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Grass N/P/S Heat Cool 6 13A foci' T , 0 201 'n m 5, 4.06 ' S99 • ;494 2878 = ; 2DD4 95 95 516 2A 2ovU 760 n , 20 52 1817 _ 30 0 616 545 0 0 0 0 2578 15 0 389 387 0 0 0 0 2A 2ov 4 960 n� 25 9f ; 2A 2ov 1 030 t1' 0 0 ffi a & 0 �� D (� 0 0 0 0 11 .2A.2ovd 103p _n r _27.81 ___..25 61 _ 6t3 __ 0 _. 1669 . ,1.537 13A-2ocs 0.201 a 5.43 4.06 506 156 844 631 0 0 0 0 2A-2ov 1.030 a 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ov 1.030 a 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ovd 1.030 a 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ovd 1.030 a 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ovd 1.030 a 27.81 60.17 200 0 5562 12033 0 0 0 0 2A-2ovd 1.030 a 27.81. 25.61 70 70 1947 1793 0 0 0 0 2A-2ovd 1.030 a 27.81 25.61 80 80 2225 2049 0 0 0 0 13A 2ocs` p 20! s 543 406 `� 188 V"''"" "'" 141 Z67 ,574 0 0 0 d 10C V. ! 030 s 27.81 16 31 - ` 27 27 Z42 435 0 0 0 0 2A 2ov ba U 76D s 0.0O 0 00Q b 0 0 0 0 0 0 2A 2ov ;�, 0 760 s 0;00 0 00 0 0 �e �0 0 0 0 0 0' 2A2ou p760 s 0.00 s 000"0 0 0 0 0 0 0 Q W 13A-2ocs 0201.w _ 5.43 4.06 472 259 1407 1053 70 56 305 228 10C-v 1.030 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-20v 0.760 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ov 0.760 w 0.00 0*00 0 0 0 0 0 0 0 0 2A-2ov 0.760 w 20.52 43.01 41 4 846 1774 14 1 282 591 2A-2ov 0.760 w 0.00 0'0) 0 0 0 0 0 0 0 0 2A-2ov 0.760 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ov 0.760 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ov 0.760 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ov 0.960 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ov 0.960 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ov 0.960 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ov 0.960 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ov 0.960 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ovd 1.030 w 27.81 60.17 72 0 2D02 4332 0 0 0 0 _ 2A-2ovd 1.030 w 27.81 60.17 99 0 2753 5957 0 0 0 0 Rj 12C:- •psw -0 091 i 0 OQ 0.00 ' 0 0777.- 0 0 0 7"0 a 0 0 s 11DO _ .__......_.-.0.390 _nL 0.00 . -.0.00 'r - _0 _ 0 _ .:,0 D `.__0 _ 0 _.w 0 _._ 0 C 16X19-0md 0.408 1.53 1.50 775 775 1184 1166 67 67 102 100 _. F% 13E - _ 0066 .... , 1,84; 4 87 ': m � �° ° a° .. 11. 1 �;,•.���,,. 7-. F 20P-13t 0.068 0.00 0.00 0 0 D 0 0 0 0 0 F� 20P 13t U.068 = 184 ._.._..w ': >.14Z8 147$ 2Z19 _ 12@B _�.-_, 756' F 22A tpl 0.989 - 0.00 0.00 0 0 0 _ 0 0 0 0 0 ....a,,.✓-----.--r $.nA._2 e_»u ,� w-.""'RM."..,. fr ° "^""""_"rm ".,N;"`C".�.rsr'*• "----^.^w7uz--"---"- 3-:,;y--m%-----.++ :>:4 6 c) AED excursion 0 79 Envelope loss/gain 28396 37579 1327 1442 12 a) Infiltration 2178 650 206 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 0 0 Appliances/other 27001 600 Subtotal (lines 6 to 13) 30574 41849 1533 2104 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 30574 41849 1533 2104 r Duct loads 113% 8% 3887 3226 13% 7% 206 146 Total mom load 34462 45076 1739 2250 Air required (cfm) Mm 1833 92 91 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigivillwow Right -Suite® Universal 2017 17.0.03 RSU24019 2016 Dec-02 0 Page 5 ...traction)\LotlDiamondSonds\LotlDiamondSands.rup Calc = MJ8 House faces: W 9 n O U Q _1 W L CO w, W � � o L Z LL Zf0 Q W Zc.4 ® 2 p; FO N a C J ZL _Q) LU OE co c ok m LL Ix 0 z Q U y S O ' U X I. 3. cQ N }/ m U c � w C C m O N O Q CU o Qo U O U N -a 0 2 0 > V 5C N (a Q= 0) O �E USmv ii CD C O E �? o c li 10 'O C N _ O E CD 0 N LL J LLL ti 2 O m O U K Q W s o Y L 0 v Z ZLL lu ZN tN Qo � J ZL W Ou. N LL O O 0 LL t Z � In O aoaod0oo00000000o0C�ooao000o0000ao00000ao� o 00 0§ c7S ct i�f c'00 93 i�5 R� _ g � S U �F 33 Ejj «� �� Bm $ �;°d jfr� gOOa'-0000000004 QOO Ot0000 o00000o00o oOQ 00�00(�[O t� oo c� ooOc�m ^`j 'tl O a ao x 000Q000000000Q000000000000000000000tlooloou�o d o; 0 o E QQaQQ'000000000tlooaoj000000000000000000000lno o 0 f 00000 000001N0002000000000 NOQQN�CO O $(g " go 0 00 n Ooaq R§ jOOOOC,k000 p� OD m GD co j]�yY 0 0 0 Q QO O O O O O O 01,9 Oa0 O Q O O O O O O O O O O O O N O 0 a 01m O ; N VN' ;4 f�7O 0 0 0 O (O �VI cmo I c.oni E a x O x V1ri NN _ OQO 00�00000000�0 Q0Q 01N0 O.O NOO OO 000000OOO�m0�0 ( � y p 3 i I Pk o co "E 00000:0000000o tl0000m000m000000000Nooa mo 0 0 1�niO+�S�OSS SS �f0 t0 Qf7S9S OOS SS OSS SS SSS SS.n-�;S 01n CnO S�nmS { � � '+ g 'V'�ONp;�vod dd �Nu�vW00p gvd ddr�'dd dd ddd od ��}}00 Ca9g(o - Ji j[, g�ppt�3o m �+r`rn84o"�888Smmm`�w$888Q888�j888888888mm8S�"3 u�OufOnuicccor��nal�nOOtlCSuid0a 000ddddddr�niSO o 0 g NNN€ Ns N NNi.. } ===ac�ddmdmddd�mmu+wNra3333333333333333 c�� � O . x � � � �,s �L� ppp ��pp���spp p}1 tpO Epp �09 �+py �.p7 op p Q o 0 0 o O o o Epp Epp {� ( 7g 1(3 00 dddddddddadoodo, tti�iii0n CL i y{ E � H�»»>9 2�5F'i,i�So, � '� rn c �j jNNNNN NNNNNNNN N,.+>,NNN(VNNN NN NN N N N NN �OXa p C C NO 3 rn U c S W 3;E s sB TT wcoo sa �- N f9 -t 1n m 10 � / 1 3r m U 0I w N 0 mx D_' m o� d It U n m o 0 N CL � C C O0 Right-M Worksheet ahu2 DEL -AIR HEATING &AIR ' CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-3853 Web: WWW.DEL-AIR.COM Job: Lot1DiamondSands Date: 10/412016 By: FJF 1 Roan name stairs great nn 2 Exposed wall 22.5 It 32.5 It 3 Roan height 11.0 It heat/cool 11.0 ft heat/cool 4 5 Roan dimensions Roan area 18.0 x 16.0 It 288.0 ft' 1.0 x 640.8 ft %0.8 ft' Ty Construction U-value Or HTM Area (ft� Load Area (ft5 Load number (Btuhlft;°F) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross I N/P/S Heat I Cool 13A-2ocs 2A-2ov 2A-2ov 2A-2ovd 2A-2ovd 2A-2ovd 2A-2ovd 10C-v 2A-2ov 2A-2ov 2A-2ov 2A-2ov 2A-2ov 2A-2ov 2A-2ov 2A-2ov 2A-2ov 2A-2ov 2A-2ov 2A-2ov 2A-2ovd 2A-2ovd 12C Osw' -' 1 C 16X19-0md 0.201 a 5.43 4.0E 1.030 a 0.00 0.0C 1.030 a 0.00 0.0C 1.030 a 0.00 0.0C 1.030 a 0.00 0 oc 1.030 a 27.81 60.17 1.030 a 27.81 25.61 1.030 a 27.81 25.61 0, 201 s°< 5.43 4.Ok 1'U30 s': 2%81 i 16.31 0760";,D OC FC 0,7ED s : 0.000.0C O.00 0.00 _Q.960 .s `0.00 0.201 w 5.43 4.0E 1.030 w 0.00 0.00 0.760 w 0.00 0.00 0.760 w 0.00 0.00 0.760 w 20.52 43.01 0.760 w 0.00 0.00 0.760 w 0.00 0.00 0.760 w 0.00 0.00 0.760 w 0.00 0'0C 0.960 w 0.00 0.00 0.960 w 0.00 0.00 0.960 w 0.00 0.00 0.960 w 0.00 0.00 0.960 w 0.00 0.00 1.030 w 27.81 60.17 1.030 w 27.81 60.17 � b 09'I :� fl 00 a K 6A 0.408 - 1.53 1.50 Q:06r3: 1.84 0:87 0.068 - 0.00 0.00 _p0E8 1.64L1:8 n 9fl9 - 0 nn 0 n0 0 264 64 347 260! 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 200 0 5562 12033 0 0 0 0 0 0 0 0 0 0 'r 0 0" 0 0 0 0 0 0 0 0 ..." 0 0 0 :. ." . 0 = `:.. U 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 077 0� 6 _.. Lo _o �o .• o' 180 ISO 275 271 61 c) AED excursion 1 1389 -1601 Envelope loss/gain 3568 7953 9061 13122 12 a) Infiltration 309 92 447 133 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 3 690 Appliances/other 0 0 Subtotal (lines 6 to 13) 3877 80451 9508 13945 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3877 8045 9508 13945 15 Duct loads 10% 100/0 388 805 13% 7% 12781 970 r Total room load 4265 8850 10786 14915 Air required (cfm) 227 360 574 607 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Vr 0ghtwoft 2016-Dec-0209:01:19 Aft Right -Suite® Universal 2017 17.0.03 RSU24019 Page 8 ...truction)1LotlDiamondSands\LotlDiamondSands.rup Calc=MJ8 Housefaces: W Right-J® Worksheet Job: Lot1DiamondSands ahu2 Date: 10/4/2016 By: FJF DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-3853 Web: WWW.DEL-AIR.COM Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wIPbahwaft" 2016-Dec-02 09:01:19 Aft Right -Suite® Universal 2017 17.0.03 RSU24019 Page 9 ...truction)1LotlDiamondSands\LotlDiamondSands.rup Calc = MJ8 House faces: W Right-M Worksheet ahu3 DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-3853 Web: WWW.DEL-AIR.COM Job: Lot1DiamondSands Date: 1014/2016 By: FJF 1 Room name ahu3 f13 stairs 2 Exposed wall 273.0 ft 22.5 ft 3 Room height 10.3 ft 10.0 ft heat/cool 4 Room dimensions 1.0 x 392.8 ft 5 Room area 2397.0 ft2 392.8 ft' Ty Construction U-value Or HTM Area (ftj Load Area (ftj Load number (Btuh/ft? °F) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat I Cool Gross N/P/S Heat Cool s 13A 2ocs 0201 n = 5 43 4 06 508 493 27t)7 2025 30 30 163 122 2A 2ov 0.760 n O DO : 0 00 0' D 0 0 0 D 0 0 2A 2ov a, 0960 n 0 00 0 DO -; 0 0 A 0 0 0 2A�2ov e4 1t030 n<_ 2781 2237 t? q 25D 201 0 0 0 0 D 13A-2ocs 0.201 a 5.43 4.06 666 368 1994 1492 0 0 0 0 2A-2ov 1.030 a 27.81 42.11 9 2 250 379 0 0 0 0 2A-2ov 1.030 a 27.81 49.66 9 0 250 447 0 0 0 0 2A-2ovd 1.030 a 27.81 27.53 160 151 4450 4405 0 0 0 0 2A-2ovd 1.030 a 27.81 55.02 120 18 3337 6602 0 0 0 0 2A-2ovd 1.030 a 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ovd 1.030 a 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ovd 1.030 a 0.00 0.00 0 0 0 0 0 0 0 0 13A 2ocs a D:201 s 543 4 06 910 855 4641 7,,"�3472 35 142 10Cv 1:030 s°: D:OD `'-D'Do 0 0 0D. 02A S 817 11 k 11 23i204 0 0 0 0 2A 2ov r 0760 s 2052 1817 12 12 e246 218 0 0 0 0 2A 2ov 0:760 s: 20 52 ; 181728 28 575 509 0 0 0 0 2A-2au 0:960 ..:s 25.a2n104 .-103 W 13A-2ocs 0.201 w 5.43 4.06 698 526 2852 2134 160 115 624 _ 467 10C-v 1.030 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ov 0.760 w 20.52 42.76 10 1 205 428 0 0 0 0 2A-2ov 0.760 w 20.52 45.43 10 0 205 454 0 0 0 0 2A-20v 0.760 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ov 0.760 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ov 0.760 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ov 0.760 w 20.52 43.21 30 2 616 1296 0 0 0 0 2A-2ov 0.760 w 20.52 42.61 43 4 876 1818 0 0 0 0 2A-2ov 0.960 w 25.92 64.85 4 0 104 259 0 0 0 0 2A-2ov 0.960 w 25.92 57.64 9 2 233 519 0 0 0 0 2A-2ov 0.960 w 25.92 58.36 45 7 1166 2626 45 7 1166 2626 2A-2ov 0.960 w 25.92 60.79 21 2 553 1297 0 0 0 0 2A-2ov 0.960 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ovd 1.030 w 0.00 0.00 0 0 0 0 0 0 0 0 2A 2ovd 1.030 w 0.00 0.00 0 0 0 0 0 0 0 0 1�C Osw k"i U.66 006 6 6 'D 0 6 - 6 0 � 6 11D0_ g �_.0:390..._n O.OD ` A -DO "L�b LL"- 0 0 L..� _.0 S: ° ,..._0 �0 _ 0 C 16X19-0md 0.408 1.53 1.50 2178 2178 3330 3278 393 393 600 591 �_.,� 20P 13t r :_ .DM � ° ""•"`184 _ Q 87 I ,...x.x......,, -34 � r 62 =29 F 20P 13t,� 0.068 1.84 0.87 68 68 125 59 0 _ 0 0 0 26P 13k - - a:S>GB ; _, 184.7- 54 �. 54 , �.��.;�'�99 w:r m_47 �.........__... 0 __' ,. 0 F 22A-tpl w 0.989 0.00 0.00 •_ 0 0 0 0 0 0 0 0 6 c) AED excursion 110 760 Envelope loss/gain 29462 34413 2744 4708 12 a) Infiltration 3475 1037 281 84 b) Room ventilation 0 0 0 0 13 1ntemal gains: Occupants @ 230 1 230 0 0 Appliances/other 6001 0 Subtotal (lines 6 to 13) 32936 36281 3025 4792 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 32936 36281 3025 4792 15 1 Duct loads 1 14% 9% 4636 3292 14% 9% 428 434 Total room load 37573 39673 3452 5226 Air required (cfm) 1833 1833 1 168 242 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigs CKW 2016-Dec-02 09:01:19 Aft Right -Suite® Universal 2017 17.0.03 RSU24019 Page 10 ...truction)\LotlDiamondSandslLotlDiamondSands.rup Calc=MJ8 Housefaces: W Right-M Worksheet ahu3 DEL -AIR HEATING & AIR ' CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-3333853 Web: WWW.DEL-AIR.COM Job: LotlDiamondSands Date:. 10/4/2016 By: FJF 1 Room name mech2 mt 2 2 Exposed wall 13.0 ft 25.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 12.5 x 6.0 ft 75.0 W 1.0 x 240.3 ft 240.3 ftz Ty I Construction number U-value (Btuhlft2 °F) Or HTM Area (ftj or perimeter (ft) Load (Btuh) Area (ft5 or perimeter (ft) Load (Btuh) Heat Cool 1 Gross I N/P/S Heat I Cool Gross I N/P/S Heat I Cool 6 13A 2ocs' � '0 201 n. 5 43 � 4,05 2A 2ov ^., 0 760 � n. , 0 00 " ? D:OG 2A 2ov „ 0 96o n D 00 O.00 2A 2ov 7 n = 2i 8!, 22.37 030 1'I :.2A.2w�. `•` _'1,030.^:0� ,.�,�.4.OEt �Q.QC 13A-2ocs 0.201 a 5.43 4.0E 2A-2ov 1.030 a 27.81 42.11 2A-2ov 1.030 a 27.81 49.6E 2A-2ovd 1.030 a 27.81 27.0 2A-2ovd 1.030 a 27.81 55.02 2A-2ovd 1.030 a 0.00 O.00 2A-2ovd 1.030 a 0.00 0.0C 2A-2ovd 1.030 a 0.00 0.0C 32acs fl201 s 10Cv �$ 8 1030 a' OOD OOG 2A 2ov 0 760 s 20 52 1617 2A 2ov 076D s2052: i817 2A 2ov „0 760 s 20 52' �18 77 0960 . s � 25:01 2516 W 13A-2ocs 0.201 w 5.43 4.OE 10C-v 1.030 w 0.00 O.00 2A-2ov 0.760 w 20.52 42.7E 2A-2ov 0.760 w 20.52 45.43 2A-2ov 0.760 w 0.00 O.00 2A-2ov 0.760 w 0.00 O.00 2A-2ov 0.760 w 0.00 O.00 2A-2ov 0.760 w 20.52 43.21 2A-2ov 0.760 w 20.52 42.61 2A-2ov 0.960 w 25.92 _ 64.8E G. 2A-2ov 0.960 w 25.92 57.64 G. 2A-2ov 0.960 w 25.92 58.3E 2A-2ov 0.960 w 25.92 60.7E 2A-2ov 0.960 w 0.00 O.00 2A-2ovd 1.030 w 0.00 O.00 2A-2ovd 1.030 w 0.00 O.00 12CoW4';, 091 D0C{' OOG d1D0 9390. i {1.Od 0:0G C 16X19-0md 0.408 - 1.53 1.5C F 2013-131: 0.068 - 1.84 0.87 F 22A-tnl 0.989 - 000 0.017 380 0 0 2225 0 0 0 0 367 61 c) AED excursion 1 110 -437 Envelope loss/gain 1005 1233 3766 3063 12 a) Infiltration 162 48 312 93 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1 1167 12821 1 4079 3156 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1167 1282 4079 3156 15 Duct loads 14% 9% 165 116 14% 9% 577 286 Total room load 1332 13% 4655 3442 Air required (cfm) 65 65 227 159 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrho"Woft 2016-Dec-02 09:01:19 Right -Suite® Universal 2017 17.0.03 RSU24019 Page 11 truction)1LotlDiamondSands%LotlDiamondSands.rup Calc=MJ8 Housefaces: W �IEL�r� Right-J® Worksheet ahu3 DEL -AIR HEATING &AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-3053 Web: WWW.DEL-AIR.COM Job: LotlDiamondSands Date: 10/4/2016 By: FJF 1 Room name rrn 2 wic bth 2 2 Exposed wall 11.0 ft 17.5 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 4.5 x 6.5 ft 29.3 ft2 11.0 x 6.5 ft 71.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number I (Btuh/ft2.-'F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross T N/P/S Heat I Cool 1 Gros I N/P/S Heat Cod 6 13A 2ocs 0 201 n 5:43 A 4.fl6 0 0 0 t 0 fl 0 0 fl 2A 2oV -� 0 760 n:.' 0:00 _, O:QQ' 0 �.fl s0 4° 0 0 s V 0 10 d 2A 2ov; f R 0.196 n 0:00 O.UQ ° 0 0 0 0 0 0 0 _ D 2A 2ov �� 1030 n E 27:81 2237; 0 0 0 0 0 0 0 H -A IQ'W 0:. Q,Ofl � Q,00 : � _.._ 4 __.. 'Q , x�. �.L 0 Q � 0 _ _0 , 0 13A-2ocs 0.201 a 5.43 4.06 65 65 353 264 0 0 0 0 2A-2ov 1.030 a 27.81 42.11 0 0 0 0 0 0 0 0 2A-2ov 1.030 a 27.81 49.66 0 0 0 0 0 0 0 0 2A-2ovd 1.030 a 27.81 27.53 0 0 0 0 0 0 0 0 2A-2ovd 1.030 a 27.81 55.02 0 0 0 0 0 0 0 0 2A-2ovd 1.030 a 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ovd 1.030 a 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ovd 1.030 a 0.00 0.00 0 0 0 0 0 0 0 0 {3A 2acs�777 77T7bWj 77j7 5 a ' 110 597 10Cv �.030� s O.OD; 000'`0 m0 " 0 0 0 �0 0 2A 2ov A 760 s a 1 20.52 1817 0 0 0 0 0 0 0 Q' ?rA 2ov 0 760 s. 20.52 18.17 0 �0 = 0 0 0 0 00 2A2ov�,ps 0760 s' 20.52�r 18:)7' 0 D 0 0 0 0 0 '0 .2A 2ov> 'F 0.960 _.s ± 25.82' . 2&7t1 Q Q _.. ..0 . 0 _ ...'Q .._ ,. 0 >. 0 0: W 13A-20cs 0.201 w 5.43 4.06 0 0 0 0 65 61 331 248 10C-v 1.030 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ov 0.760 w 20.52 42.76 0 0 0 0 0 0 0 0 2A-2ov 0.760 w 20.52 45.43 0 0 0 0 0 0 0 0 2A-2ov 0.760 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ov 0.760 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ov 0.760 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ov 0.760 w 20.52 43.21 0 0 0 0 0 0 0 0 2A-2ov 0.760 w 20.52 42.61 0 0 0 0 0 0 0 0 2A-2ov R960 w 25.92 64.85 0 0 0 0 4 0 104 259 2A-2ov 0.960 w 25.92 57.64 0 0 0 0 0 0 0 0 2A-2ov 0.960 w 25.92 58.36 0 0 0 0 0 0 0 0 2A-2ov 0.960 w 25.92 60.79 0 0 0 0 0 0 0 0 2A-2ov 0.960 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ovd 1.030 w 0.00 0.00 0 0 0 0 0 0 0 0 2A-2ovd 1.030 w 0.00 0.00 0 0 0 0 0 0 0_ 0 12COsw Q091 fl.00, 0OD'n °'_ Q."..77, 0 0 7. 0 0 0 0 Q _ZQ 39a h ___.a0o ... Sao' m 0 �Q __ _0 n �Q o c 16x19-Omd 0.408 - 1_53 1.50 29 29 45 44 72 72 109 106 F mm0 068 184 0.87 ' `.._... 0 p F 20P-13t 0.068 - 1.84 0.87 0 0 0 0 0 0 0 0 =3W ._ 0.8Z _ Q __. D _..-,.-.�, ..fl " ' Q 0 F 22A tpl 0.989 0.00 0.00 0 0 0 0 0 0 0 0 77=7- ....... .,,_' z-- .:.`w..,..... aw...�.•.;:....,.' ..�. ,. .......mow.. _:.�. mil_ 6 c) AED excursion -65 -33 Envelope loss/gain 642 426 1141 1028 12 a) Infiltration 137 41 219 65 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 01 0 Subtotal (lines 6 to 13) 779 467 1360 1094 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 779 467 1360 1094 15 Duct loads 1 14% 90/0 110 42 140/6 9% 192 99 Total room load 889 509 1552 1193 Air required (cfm) 43 24 76 55 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. a, -rk 1AIRupA1}t'&i ft. 2016-Dec-02 09:01:19 Right -Suite® Universal2017 17.0.03 RSU24019 Page 12 ..truction)lLotlDiamondSands%LotlDiamondSands.rup Calc=MJ8 Housefaces: W G W f0 84 W N p� D� Do) ,OFF 23� 10 :s m m a�_.� -� 3 d Io 8 m o o p_p N 0 N m n = � N O VW OA000 A O+� N (per A N co L71 N OND O O O fT O O O &UIS9 DDDDDDDD Y. CL ,000000000000,0 gMugggann ffffff�fffffff� N N N N N N N N O pO tlt (11 f110�00 Np0 p0 p000 p0 (A71 N O O O Npp N O W O O O V A itA W O O O N N o A WN SSS hrn S�R �OrS,£0000000000000000 1000;0000000000000000 N N N N N N N 0000000 nnnna 0 0 V V V 74. m 8O �W11W a�D jD 00Nr(�tpmO�N pA SSNCJ �f�S 00000000 00000000 (n4, WN-+ ;'11' �+ m =m �cpp� �°CD = ON ID 2 0 �1 m C � n3 OO N ? V O 3� O o � O N X O CO 2 pp V O =, g g oy � � m N � x m� X cn W x g, c _ 8 g 0 O O W x amiz T O M 0 N ;v v lbvo m -• .z v nA. 1••h �Z > °yy„Z d O x� Z g +) N V go 3 �i CD rf W 0 r X O O 9 0 01 °a co .. 0 0 T `, .a O C ti CD 3 0 7 a CO) 7 a N C 8L� 1 F Right-M Worksheet ahu3 DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-3333853 Web: WWW.DEL-AIR.COM Job: Lot1DiamondSands Date: 10/4/2016 By: FJF Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Dec-02 09:01:19 Right -Suite® Universal 2017 17.0.03 RSU24019 Page 14 ...traction)lLotlDiamondSandslLotlDiamondSands.rup Calc = MJ8 House faces: W M :seoel esnoH grw = oleo dru•spuespuowe!Olio-!ispuespuowelONoii(uolioNi"' 9L e6ed 6104Znsd E0'01l LWZ IeSrenlun @9j!nS-!461a 6l:10:60 Zo-0ea-9LOZ ASOMM45prA 'p3 Mo r lenueW Jo s;uawaim as lie jeew o; VOOV Aq paAoidde suoppoleo. We 69Z CS M (w1o) pw!nbai j!V OEM 90E5 ZOEE 996Z peol woajleiol E89 L99 %6 %4l 4LZ L9E 0/66 %44 speOl ion0 SL L45L 9694 9Z0E 669Z IeloignS 4l 0 0 0 0 uolinquislpaa 0 0 0 0 191sum SSG] 0 0 0 0 Peol !ewapm ssal L09L ent? BZO£ 669Z (EL of 9 saull) Ieioign8 009 0 ja43o/saouel!ddV O£Z l 0 0 OEZ @ swwnoop :sule6!ewaiul £L 0 0 0 0 uo!18111-A woos (q OB 99Z COL 9K uo!iw8!1ul (e ZL LE99 08E4 4Z6Z £SZZ u1e6/ssol adolanu3 OZe- 49£ ualsmoxe a3V (0 9 LE4 0 U U 0 0 0 0 0 0. 68 _�, 6LL, 0 0 0 0 0 0 Z099 LE££ 0 0 0 0 0 0 'L £9'l OOVO PUAML 91 .0 00'0 m 060'6 µPAOe-VZ '0 00'0 m OEO'l PAOe-VZ '0 00'0 m 096'0 noZ-yZ .m Z6'9Z m 096'0 AoZ-VZ 'BS Z6'9Z m 096'0 AoZ-VZ 'L5 Z6'9Z m 096'0 AOZ-VZ '49 Z6'9Z m 096'0 noZ-VZ 'Z4 Z5'0Z m 09L'0 AoZ-VZ '£4 ZS'OZ m 09L'O AoZ-VZ '0 00'0 m 09L'0 AoZ-VZ '0 00'0 m 09L'O AoZ-VZ '0 00'0 m 09L'O AoZ-VZ '614 Z9'0Z m 09L'O noZ-VZ 'Z4 Z9'0Z m 09L'O n0Z-yZ '0 00'0 m OEO'l A-001 '4 E4'S m LOZ'O SMZ-VEL oo Dv, - 000 s Ow L YA-ool . 00*0 00'0 a oeo'L PAoZ-VZ or— OTO 00'0 a OEO'l PAOZ-VZ 00*0 00'0 a 0E01 PAoZ-VZ Z0'95 L8'LZ a OEO'L PAoZ-VZ ME L9'LZ a OEO'l PAOZ-VZ 99'64 l9'LZ a OEO'l noZ-VZ Ll'Z4 l9'LZ a OEO'l noZ-VZ SOZ 4LZ l5 lLl 0 0 0 0 9011 £4'S a LOZ'O SOOZ-V£l 0 0 0 0 0 0 0 0 0 0 '^ 0 D, 0; �. 0-' 0 = 0 �L£7Z 00 0 ttb a 68LZ U, O✓ l pE0'L 1�p!OV y:� r�x J�Oe:W l L 0 0` e. 0 0- 0, %` 0_ 0 0 00 0 000 u 096 0 noZ-VZ 0 0 0 r 0' ` 0 : 0 ";� 0- 0 00 0 000 u O8L'p noZ vz 9 loon ieaH S/d/N sswa 1000 ieaH S/d/N sswa 1000 1 ieaH (do-.i1/4nis) Jaqumu (4n3e) jaiawuad jo F (4nle) (11) jaiawuad jo GII/4nie) Peol Gil) —V pem Gu) —V W1H jo an!en-n uolioruisuoo Ll ri1 £'01 Al 9'99L ewe woos S 8 £'Mr x 0'l u TEL x 5'Zl suolsuawlp woos 4 10001Ma4 u 0'll 1003/Iee4 u £'Ll VAN woos £ N 5'% 4 Tire 11— pasodx3 Z uL Jisw 831110 aweu woos l INOo'aIV-l3a'MMM :geAA ESBE-£££-LOh xed 999Z-LEB-LO4 :auoyd ULZE 1=1 'abO=INVS AVM OOSIOOO Mg JNINOIlIaNOO • 211b�'8 JNIlV3H 211H-13a - drd :As %oz/4/U .aaea gnye ��a trurrl, ra spuespuowe!a63o1 :4or ;Gays)IjoM or-;4s!21 t � Q Right-M)Worksheet ahu3 DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-3853 Wab: WWW.DEL-AIR.COM Job: Lot1DiamondSands Date: 10/4/2016 By: FJF 1 Roan name mstr bar mstr we 2 Exposed wall 0 ft 5.5 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Roan area 5.0 x 10.5 ft 52.5 ftz 5.5 x 4.5 ft 24.8 ft' Ty Construction U-value Or HTM Area (M Load Area M Load number I (Btuh/ft? °F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 13A-Locs U.LUI a o.4s 4.uti u 2A-2ov 1.030 a 27.81 42.11 0 2A-20v 1.030 a 27.81 49.66 0 2A-2ovd 1.030 a 27.81 27.53 0 2A-2ovd 1.030 a 27.81 55.02 0 2A-2ovd 1.030 a 0.00 0.00 0 2A-2ovd 1.030 a 0.00 0.00 0 13A-2ocs 0201. w 5.43 4.0E 10C-v 1.030 w 0.00 0.0C 2A-2ov 0.760 w 20.52 42.7E 2A-20v 0.760 w 20.52 45.42 2A-20v 0.760 w 0.00 0.0c 2A-2ov 0.760 w 0.00 0.0C 2A-2ov 0.760 w 0.00 0.0C 2A-20v 0.760 w 20.52 43.21 2A-2ov Q760 w 20.52 42.61 2A-2ov 0.960 w 25.92 64.8E 2A-2ov 0.960 w 25.92 57.64 2A-2ov Q960 w 25.92 58.3E 2A-2ov 0.960 w 25.92 60.79 2A-2ov 0.960 W 0.00 0.0C 2A-2ovd 1.030 w 0.00 0.0C 2A-2ovd 1.030 w 0.00 0.0C 12C-Oaw' � 1100 °F J).390 n - 0.06 -_' (IOC 16X19-0md 0.408 - 1.53 1.5C OOP 13t== =6068 =jW < W 20P-13t 0.068 1.84 0.87 20P 13t. s :.: ..�. _ A.068 _ 1,8.4: 99G_fH n oAq _ n nn n m 0 0 0 0, 0 0, 0 0', 0 0 0 0 0 0 0 0 0 0 6 c) AED excursion 1 -3 -55 Envelope loss/gain 27 23 517 375 12 a) Infiltration 0 0 69 21 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 271 23 586 396 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 27 23 586 396 15 Duct loads 14% 90/0 4 2 14% 9% 83 36 Total room load 31 25 669 431 Air required (cfm) 1 1 33 20 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Ww righ" 2016-Dec-02 09:01:19 Right -Suite® Universal 2017 17.0.03 RSU24019 page 17 ...traction)\LotlDiamondSands\LotlDiamondSands.rup Calc=MJ8 Housefaces: W M :seoeW ;esnoH g�_o!eo dru•spuegpuowe!OL;ollspuespuowe!a"oli(uogoru;•.• 9L e6ed 61:10:60 ZO•oa0-9LOZ slobznsa Eo o u uoz IBsteR!un cans we!a 'P3 Me f lenueW jo sluawa.Jln ai lle;aaw 01 VOOV Aq paAoi a suollelnoleo VL Be 90L Z% (wJ0) pw!nbw j!v 68% LLBL ZZ£Z LZ££ Peol wont lelol Z£L Vzz %6 °/OK E6l LW °/66 %4L speol hna 5L LM L89L 6ZLZ OWZ IelolqnS 4L 0 0 0 o uoilnqulslPaa 0 0 0 0 Asued ssel 0 0 0 0 peol lewepra ml LS6l L99L 6Z2 M6Z (£L ol9 scull) lelo3gnS 0 0 js430/saauegddV 0 0 0 0 o£Z @ sluedn000 :su1e6leweluI £L 0 0 0 0 UOIWIIJ-A woos (q LL L£Z 0" 69£ uoliwA!Jul (B ZL 99E1 64£L 6LOZ Lh9Z ule6/ssol 9d0l8nu3 £9 96Z- uoistnoxa 03V (0 9 o`er o o'-��: p ....x._ 0_ _.> P __ q _" o .��.., za o �9 L.��.. = est�o, �c �oz 0 0 0 0 _ 0 ' Om mm 0 mm 0 L9'O "I 990'0 1£L-dOZ R d 0.._ _ .. 0 _ 0. ... " ".� 0� 0 .. 0 AV— WI es0'0 _ �4 doZ, 3 99L LM _ -- MM M MLOZ LOZ 09'L £9l SOVO pu"WL 0 0-7— _ o 0 0— 07 0�m o: 0 0070� 00o -u06VO TOQCI P 0 9 Q o`- u o o. o qoo. . 000 ,6qO 0 0 0 0 0 0 0 0 00'0 00'0 m 0£0' L PROZ-VZ 0 0 0 0 0 0 0 0 00'0 00'0 m 0£0' L PRoZ-VZ 0 0 0 0 0 0 0 0 00'0 00'0 M 096'0 RoZ-VZ 0 0 0 0 0 0 0 0 6L'09 Z6'9Z m 096'O ROZ-VZ 0 0 0 0 0 0 0 0 9£'89 Z6'9Z m 096'0 ROZ-VZ 0 0 0 0 0 0 0 0 49'L9 Z6'9Z m 096'0 ROZ-VZ 0 0 0 0 0 0 0 0 99'49 Z6'9Z M 096'0 ROZ-VZ 0 0 0 0 0 0 0 0 W717 Z9'OZ m 09L'0 ROZ-VZ 0 0 0 0 0 0 0 0 OD Z9'0Z m 09L'0 ROZ-VL 0 0 0 0 0 0 0 0 00'0 00'0 m 09L'O ROZ-VZ 0 0 0 0 0 0 0 0 00'0 00'o m 09L'0 ROZ-VZ 0 0 0 0 0 0 0 0 00'0 00'0 m 09L'O ROZ-VZ 0 0 0 0 0 0 0 0 £6'96 ZS'OZ m 09L'o ROZ-VZ gZ4 90Z L OL 0 0 0 0 9L'Zt4 Z9'OZ m 09L'0 ROZ-VZ 0 0 0 0 0 0 0 0 00'0 p0'0 m o£0'l R-001 49Z o9£ OL 09 0 0 0 0 901F £h'9 m LOZ'0 sooZ-V£L M 0 0 0,: 0 0- 0 SZ 9Z _ Z6 5i 3— 098 KoZ 0 O O O 609 9L9 9Z $Z LL 9L �m Z5 OZ ' ' S 09L'O' ROZ 0 0 0 0 0 0 0 0 a L: LL Sl a Z5 OZ z s" 09L'0 R0Z-VZ 0 0 0° < U LL 8L js �9 OZ 5 09L'0 pnoZ^tfi 0 0 0 0 0 0 .: 0`- 0 00 0% t W 0 s OEO L n 001 "_ :...._.. �.G L65 04L.,., ,.;- Q(F 6,l $tOl 19L _-,,,,,,;.,` 9LZ W .. 0 0 0 0 0 0 0 0 W'0 00'0 a 0E01 PROZ VZ 0 0 0 0 0 0 0 0 00'0 00'0 a o£0'L PROZ-VZ 0 0 0 0 0 0 0 0 00'0 00'0 a o£0'L pnoZ-VZ 0 0 0 0 0 0 0 0 Z0'99 L9'LZ a o£0'L PROZ-VZ 0 0 0 0 0 0 0 0 £9'LZ L8'LZ a O£O'L pnoZ-VZ 0 0 0 0 L" o9z 0 6 99'64 L9'LZ a OM'l ROZ-VZ 0 0 0 0 0 0 0 0 474 L9'LZ a OCT L RoZ-VZ 0 0 0 0 e8Z SS£ LL 09 90'4 £4'S a LOZ'0 sooZ-V£L o o o o 0 0 0p o 00 0 00 og ,� ` u �e0 pRoz bz _ L L 0 0 0 0 © 18 LZ U OEO`l �Z Vl s o9ro 0 0 o a o o x o; 0 00 0 00 0 u 09s'o Roz:t2 0 0 0 0 0 o 0 0 00 0 o0 o u RoZ vz 0 0...:"._.o &�_ o z o.'_ -o pt so�s..3`u pogo".zr�e4m s 1000 WaH S/d/N sswJ 1000 WOH S/d/N SSOJE) 1000 IMH (4n18) (11) ialawuad Jo (4nle) (4) jalewuad jo Gu 4n18) (do z1J/4n18) jagwnu peol 6s) —V peol Gv) —V W1H jo an!eR-n uollaw;suo0 Al. zu 9'6M .11 9'90Z Bate woos 9 u 9'6M x o'L u 9'90Z x O'L suoisuawip woos 4 1003/1Ba4 u O'OL l000/1a4 u O'OL 146!a4 woos £ u O'M U 9'6Z llem pasodx3 Z aim i1sw 41q i1sw eweu woos L WOO'NIV-130'MMM :geAA Me-eSE-LOh xej 999Z-L88-LOb :euo4d ULM ld 'OaOdNVS AVM OOSI000 L£9 JNINOIIIaNOO aIV V JNIld3H HIV-130 %ozilplU .03eO Exile VIOLLOWrrr + 1, spuespuowelapol aor iaays��oM O('"�4B21 U-L'iA Right-J® Worksheet ahu3 DEL -AIR HEATING &AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-3333853 Web: WWW.DEL-AIR.COM Job: Lot1DiamondSands Date: 10/4/2016 By: FJF pwdr 5.0 ft 10.0 ft heat/cool 8.0 x 5.0 ft 40.0 ft' Or HTM Area Load Area Load (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter Heat I Cool I Gross N/P/S Heat I Cool 1 Grass I N/P/S Heat I Cool Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. VS rIgS►w 2016-Dec-02 os:ge 9 Right -Suite® Universal 2017 17.0.03 RSU24019 Page 19 ... traction)\LotlDiamondSands%LotlDiem ondSands.rup Calc = MJ8 House faces: W Duct System Summary Job: LotlDiamondSands Date: 10/4/2016 DIE ahul By: FJF DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-3853 Web: WWW.DEL-AIR.COM For: Phoenix Realty Homes External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.38 in H2O 0.06 in H2O 0.32 in H2O 0.160 / 0.160 in H2O 0.244 in/100ft 807 cfm Cooling 0.38 in H2O 0.06 in H2O 0.32 in H2O 0.160 / 0.160 in H2O 0.244 in/100ft 807 cfm 131 ft Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk bonus nn h 3587 182 172 0.354 7.0 Ox 0 VIFx 20.3 70.0 bonus rm-A h 3587 182 172 0.363 7.0 Ox 0 VIFx 18.0 70.0 bonus rm-B h 3587 182 172 0.280 7.0 Ox 0 VIFx 29.2 85.0 st3 lobby c 6799 262 291 0.244 9.0 OxO VIFx 46.4 85.0 st3 Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st3 Peak AVF 444 463 0.244 590 12.0 0 x 0 VinlFlx Return Branch Detail Table Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/JDist Opening (in) Duct Matl Trunk rb2 Ox 0 807 807 0 0 0 0 Ox 0 VIFx Ir ow Right -Suite® Universal 2017 17.0.03 RSU24019 ...traction)\LotlDiamondSands\LotlDiamondSands.rup Calc=MJB Housefaces: W 2016-Dec-02 09:01:22 Page 1 U;AIRDuct System Summary ahu2 DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-831-2665 Fax 407-333-3853 Web: WWW.DEL-AIR.COM Project• • For: Phoenix Realty Homes Job: Lot1DiamondSands Date: 10/4/2016 By: FJF Heating Cooling External static pressure 0.25 in H2O 0.25 in H2O Pressure losses 0.06 in H2O 0.06 in H2O Available static pressure 0.19 in H2O 0.19 in H2O Supply / return available pressure 0.095 / 0.095 in H2O 0.095 / 0.095 in H2O Lowest friction rate 0.086 in/100ft 0.086 in/100ft Actual air flow 1833 cfm 1833 cfm Total effective length (TEL) 221 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk bth h 2515 134 77 0.088 6.0 Ox 0 VIFx 65.2 150.0 st9 club bar c 363 9 15 0.092 4.0 Ox 0 VIFx 56.8 150.0 st8 club rm c 4374 137 178 0.090 9.0 OxO VIFx 61.3 150.0 st8 club nn-A c 4374 137 178 . 0.089 9.0 OxO VIFx 63.3 150.0 st8 dining h 2679 142 89 0.091 8.0 OxO VIFX 57.9 150.0 st8 greatnn c 7458 287 303 0.108 10.0 OxO VIFx 40.1 135.0 st7 great rm-A c 7458 287 303 0.114 10.0 OxO VIFX 32.2 135.0 st7 kitchen h 3580 190 119 0.088 9.0 Ox0 VIFX 66.1 150.0 st9 kitchen -A h 3580 190 119 0.090 9.0 Ox 0 VIFx 60.2 150.0 st9 stairs c 4425 113 180 0.107 9.0 Ox 0 VIFX 42.7 135.0 st7 stairs -A c 4425 113 180 0.105 9.0 Ox0 VIFx 45.5 135.0 st7 utility h 1739 92 91 0.086 6.0 OxO VIFx 70.6 150.0 st8 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st8 Peak AVF 518 551 0.086 516 14.0 0 x 0 VinlFlx st7 st9 Peak AVF 515 315 0.088 481 14.0 0 x 0 VinlFlx st7 st7 Peak AVF 1833 1833 0.086 1313 16.0 0 x 0 VinlFlx st4 st4 Peak AVF 1833 1833 0.086 694 22.0 0 x 0 VinlFlx Tr Wr4oftar Right -Suite® Universal2017 17.0.03 RSU24019 ...truction)lLotlDiamondSands%LotlDiamondSands.rup Calc = MJ8 House faces: W 2016-Dec-02 09:01:22 Page 2 t- Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1833 1833 0 0 0 0 Ox 0 VIFx wrviftlaft, Right -Suite® Universal2017 17.0.03 RSU24019 ...truction)\LotlDiamondSands\LotlDiamondSands.rup Calc = MJ8 House faces: W 2016-Dec-02 09:01:22 Page 3 m o� O C O O. ca C N � m m � m N -4 n u � �0 OD x co m 0 m m N 3 3 T7a R 3 3 3 3 3 Q Q O A A W W N N ? m O N A W N m £ E E F£ Q o 0 0 0 0 D v CD CD = 0 = = = = 0 0 = = 0 n = = = O = = = �CD (_ CA W W i p p W i CJ7 N- NODmr1l D�00 W OD CAii W WN VCAUf CA CA)O OD OD CA O i (3) j W CA) 002 OCOCA)MWC" N—wCYI T iNOCDO M W N -4 CA) OV(DW-40mwW0w111) U7ODVOCA 00 V i -� N U1 W U7 V NCO CO O CA A NN V CJ1 i (O V O CT CO CO W W P 0 OD CT N N 0o U1 v 0000000000000000000 my. i i i i i i i i i i -- i i i Con AW W W V VOWNNNWNO(OOD:aNV �7 -N CA UI CT --• N O W W V CA N N N M" -4 O �o;AOD;NP.N w0-N0mwt�-tnmP.rntn v� 0000000000000000000 0000000000000000000 x k X X X X X X X X X X X X X X X X X X _ 0 7 WW AANNiN pA PW AN iiW cqNN UICOOO. W WOOUIN n snSO. W9)p�ON -•W AW40W V-t-N OD.PV0 CO .� 0CD0C)w D00--ii—CO OD OD0CDw Ca O O O O M O M M O 0 0 0 0 m m m O 0 U1 O O C O O O O O O O O C O O O O O O O .-. p tnmwCnmCnmmmtn�mmwtaCnww� '� 1 r! -Y• N• N• rF K ,T rh rr in •M •rt �r M N• r► M O�tAtnNNiiCTU1CJfCTCTiNNtAInN � 7C' y om O n (_ C 1 x CD CD .. CD N .n....fD..fA.� O N O •� M CD C) cc CD N �c m �m CD CD Cn Cn C CD 0 cn O O co:,N6000 W Nchco W �CD 3 ONNNNo 20000 cn rn o O CC°n i O O O iN 0 0 0 0 mwmcho 0 Z 7 7 7 C N N N NCC 0000 n "" - O O CD, 0 O D Z -n O O d 0 N m s s o D _ W r O 2. mCD A V/ X CD 0) m D MIL N 2 B R Z ci CD CA A w Qp 3 m v_ � si 5w a Z • v 0 m r 0 • s Z 0 Z O im L p�j O L CD 0 T A � N O o rn 3 0 C a CO a U) V^ Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st5 Peak AVF 542 582 0.122 545 14.0 0 x 0 VinlFlx st1 st6 Peak AVF 539 512 0.127 687 12.0 0 x 0 VinlFlx st2 st2 Peak AVF 1119 1057 0.127 633 18.0 0 x 0 VinlFlx st1 Peak AVF 714 776 0.122 556 16.0 0 x 0 VinlFlx Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb3 Ox 0 1833 1833 0 0 0 0 0x 0 VIFx WfthtSOW Right-Suite(D Universal 2017 17.0.03 RSU24019 ...traction)\LotlDiamondSands\LotlDiamondSands.rup Calc=MJ6 Housefaces: W 2016-Dec-02 09:01:22 Page 5