Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
EPL Display Card 7-19-13
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 79 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units; if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft) 7. Windows" Description a. U-Factor: S91, U=0.55 SHGC: SHGC=0.50 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: #921 VENTURE III, FT. PIERCE, FL, New (From Plans) 9. Wall Types Insulation Area a. Concrete Block - Ext Insul, Exterior R=4.1 1558.00 ft' Single-family b. NIA R= ft' 1 c. N/A R= ff 2 d. N/A R= ft2 10. Ceiling Types Insulation Area No a. Under Attic (Vented) R=30.0 1427.00 ft' 1427 b. N/A R= fN c. NIA R= ftz Area 11. Ducts R ftz 321.50 ftz a. Sup: Attic, Ret: Attic, AH: Main 6 195 ftz 12. Cooling systems kBtu/hr Efficiency ftz a. Central Unit 19.2 SEER:16.00 ftz 10.796 ft. 0.500 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1427.00 ftz b. N/A R= ftz c. N/A R= ffz 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be' installed (or exceeded) in this home before final inspection. Otherwise, a new Display Card will be completed based on installed Code co nt fe res Builder Signature: { D I �, y Date: 7/ /q //S- r Lf— „ - Address of New Home: �AO 5 , p 4_D�, City FL Zi : Jewel kBtu/hr Efficiency 27.0 COP:1.00 Cap: 40 gallons EF: 0.92 COD WE - ;Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM),incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. *'Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Proj� Summary Job: : -�+ wrightsoft Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM For. KEVIN FLOYD #/921 VENTURE III, FT. PIERCE, FL Notes: Weather: Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 25432 Btuh Ducts 4916 Btuh Central vent (23 cfm) 714 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 31062 Btuh Infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average 0 Heating Cooling Area (ft2) 1427 1427 Volume (ft3) 11608 11608 Air changesthour 0.45 0.23 Equiv. AVF (cfm) 87 44 Heating Equipment Summary Make Trade Model AHRI ref no. n/a Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 0 Btuh 31062 Btuh 29 OF 973 cfm 0.032 cfm/Btuh 0 in H2O Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 14653 Btuh Ducts 7372 Btuh Central vent (23 cfm) 383 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 21287 Btuh Latent Cooling Equipment Load Sizing Structure 1859 Btuh Ducts 2000 Btuh Central vent (23 cfm) 970 Btuh Equipment latent load 4829 Btuh Equipment total load 26116 Btuh Req. total capacity at 0.70 SHR 2.5 ton Cooling Equipment Summary Make Rheem Trade RHEEM 14AJM SERIES Cond 14AJM30 Coil RHLL-HM3617++RCSL-H*3617 AHRI ref no. 3412355 Efficiency 13.0 EER, 16 SEER Sensible cooling 20440 Btuh Latent cooling 8760 Btuh Total cooling .29200 Btuh Actual air flow 973 cfm Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.82 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. W I-1 Ilt50ft" 2013Jul-Jul13:52:28 9 RightSuite@ Universal 2012 12.0.07 RSU08101 Page 1 .y--GF: C:1Users%Quick Caics%DocumentslWdghtsoft FNACTLOYD, KEVIN.rup Calc = MA Front Door faces: N wri htsoft, Ri I1® Worksheet Job: 9 g �" . - Entire House date: QUICK CALCS, INC. By; 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 'Room name Entire House LMNG/KITCHEN 2 Exposed wall 236.3 ft 79.1 ft 3 Room height 8.0 ft d 8.0 ft heat1cool 4 Room dimensions 1.0 x 618.0 ft 5 Room area 1451.0 ft2 618.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft? °F) (Btu ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat ' Cool Gross N/P/S Heat Cool 6 V 13AAocs 0.143 n 4.06 2.55 336 162 648 412 169 41 166 105 _�G 1Aciom 1.270 n 35.56 17.90 48 0 1719 865 0 0 0 0 II IA-hiomd 1.270 n 35.56 17.98 127 0 4528 2289 127 0 4528 2289 13AAocs 0.143 a 4.00 2.55 576 530 2122 1349 232 202 809 514 11 1A-h1onn 1.270 a 35.56 40.85 7 0 249 286 0 0 0 0 1A-hlom 1.270 a 35.56 40.85 9 0 320 368 0 0 0 0 IA-hlom 1.270 a 35.56 32.74 30 0 1067 982 30 0 1067 982 13AAocs 0.143 se 4.00 2.55 186 150 601 382 0 0 0 0 1Aclom 1.270 se 35.56 27.28 30 0 1067 818 0 0 0 0 1A hlom 1.270 se 35.56 27.64 6 0 213 166 0 0 0 0 w 13AAocs 0.143 s 4M 2.55 168 168 673 428 0 0 0 0 W 13AAocs 0.143 w 4.00 2.55 624 550 2202 1400 232 186 745 473 1A-hlom 1.270 w 35.56 40.85 12 0 427 490 0 0 0 0 1A-hlom 1.270 w 35.56 32.74 32 0 1138 1048 16 0 569 524 IA-hiom 1.270 w 35.56 32.74 30 0 1067 982 30 0 1067 982 C 16B30md 0.032 0.90 1.68 984 984 882 1653 151 151 135 254 F 22A-tpl 0.989 - 27.69 0.00 984 138 3831 0 618 79 2190 0 6 c)AED excursion 0 -154 Envelope loss/gain 22753 13919 11275 5971 12 a) Infiltration 2679 734 896 245 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 25432 146531 12171 6216 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 25432 14653 12171 6216 15 Duct loads 19°/a 50% 4916 7372 191/0 50% 2352 3128 Total room load 30348 22025 14524 9344 Airrequired.(cfm) 973 973 L 466 413 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 44- wrightsoft- 2013-Jul-1513:52:28 r`x Right -Suite® Universal 2012 12.0.07 RSU08101 Page 1 C:\Users\Quick Calcs\Documents\Wdghtsoft+IVACTLOYD, KEVIN.rup Calc = MJ8 Front Door faces: N " C m m 0 U Oq U U J S Y U_ 5 C% W T O �1 r `t- Qg �« -Moo f00 OOOONO0000 �O 0004�C 9F-', �ufOi x o00goao200oCDC) oorOF 0 o L VD o cn "E -000so00�ocoOCO00�� o 0 OD rn 000 000000000 OOr0 - - tr rno 00 In OOOInF Nr �tv ram- N N Rr 8 c� 'O OO�lOOOOOOOOOOO Es- NO OOONO�; n In O cO m O = x (p OOOOOOOOOO OtD - '77 0D op CDOOOODO v (n a In v �rw _�� «d Z , 0 0 C 000 F80 oOoco coo Oo $ R O e co N T o i� 4 I� �p I� �n �n In �n IInn �Inn pppp.p In�TInW aOt)�In N�In In OpD �c�cVV t00 Nen-n_N�OMNNNNNO�MrO �F� o �(pp E�pppp�p �Vpp'��ppp�p �p pp�Vp �p �p 8 1n ltnn' O 0 0 0 2 m N v N ��n tLLn7 �1nn �1nn tLLn') tlnn �tno ttIonn a9ch f9 t�c'7� 9c'7�� 99 mON O C C C m tV N m y N N N �� ai m O O M 0 0 0 O O M O O O N O rnnvnnn�nnv�n1� nM 0 N N r N N N r N N r r N N N o��C3C), Q0 Dm o n o EE. �C 3i`o V = �Q���c�+d��Tdc� y_ •rn .�a_v c� lE E C m� ° S in y!�22` y t— �JT<n� °a tc a r NM vcn 21 U +�- wrightsoft, Righ,__,J® Worksheet - ' Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM 4 Room name PWDR. MASTER BEDROOM 2 E)osed wall 6.0 ft 31.6 ft 3 Room height 8.0 ft heat/cool 8.0 It heat/cool 4 Room dimensions 3.0 x 6.0 ft 1.0 x 197.0 ft 5 Room area 18.0 ft2 197.0 ftz Ty Construction U-value Or HTM Area (ft-) Load Area (ftz) Load number (Btuhlft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1A-clom 1.270 n 35.56 17.90 0 0 0 0 0 0 0 0 IA-hlomd 1.270 n 35.56 17.98 0 0 0 0 0 0 0 0 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 11IA-hlom 1.270 a 35.56 40.85 0 0 0 0 0 0 0 0 N 1A-h1om 1.270 a 35.66 40.85 0 0 D D 0 D 0 0 1A-h1om 1.270 a 35.56 32.74 0 0 0 0 0 0 0 0 13A■4ocs 0.143 se 4.00 -2.55 � 0 0 0 0 125 95 381 242 1A-clom 1.270 se 35.56 27.28 0 0 0 0 30 0 1067 818 ��-- GG 1A-h1om 1.270 se 35.56 27.64 0 0 0 0 0 0 0 0 W 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 13AAocs 0.143 w 4.00 255 48 48 192 122 128 112 448 285 IA-hlom 1.270 w 35.56 40.85 0 0 0 0 0 0 0 0 N IA-h1om 1.270 w 35.56 32.74 0 0 0 0 16 0 569 524 IA-h1om 1.270 w 35.66 32.74 0 0 0 0 0 0 0 0 C 16B30md 0.032 0.90 1.68 18 18 16 30 197 197 177 331 F 22A-tpl 0.989 27.69 0.00 18 6 166 0 197 32 875 0 6 c)AED excursion 4 55 EnWope'loss/on 374 148 3517 2145 12 a) Infiltration 68 19 359 98 b) Room ventilation 0 0 0 0 13 internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1 442 1671 3875 2243 Less mdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 442 167 3875 2243 15 Duct loadS 1 19% 50% 86 84 19% 50% 749 1129 Total room load 528 251 4624 3372 Air required (cfm) 17 11 148 149 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsof - 2013-Jul-1513:52:28 Right -Suite® Universal 2012 12.0.07 RSU08101 Page 3 C:\Users\Quick Calcs\Documents\Wdghtsoff HVAC\FLOYD, KEVIN.rup Calc = MJ8 Front Door faces: N +I+ wrightsofr RigL `�® Worksheet J. Job: Entire House Date: BY: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772A66-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1' 'Room name OFFICE BEDROOM 2 Evosed wall 20.0 ft 23,11 ft 3 Room height 80 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 105.0 ft 1.0 x . 126.5 ft 5 Room area 105.0 ft2 126.5 ft2 TY Constriction U-value Or HTM Area (ft2) Load Area (ft2) load number (Btuh/ftk F) (Btuh/ft2) or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 % I G 13A4ocs 0.143- n 4.06 2.55 . 86 64 -258 164 88 56 224 143 1Aclom 1.270 n 35.56 17.90 16 0 569 286 32 0 - 1150 579 l-G 1A-hlomd 1.270 n 35.56 17.98 0 0 0 0 0 0 1 0 0 VVV���JJJ 13AAocs 0.143 a 4.00 2'55 0 0 0 0 96 89 356 227 11 1A-hlom 1.270 a 35.56 40.85 0 0 0 0 7 0 249 286 1A-hlom 1.270 a 35.56 40.85 0 0 0 0 0 D 0 D 1A h1om 1.270 a 35.56 32.74 0 0 0 0 0 0 0 0 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1A clom 1.270 se 35.56 27,28 0 0 0 0 0 0- 0 0 1A-hlom 1.270 se 35.56 27.64 0 0 0 0 0 0 0 0 W 13A-0ocs 0.143 s 4.00 255 0 0 0 0 0 0 0 0 13A4ocs 0.143 w 4.00 2.55 80 74 296 188 0 0 0 0 1A,h1om 1.270 w 36.56 40.85 6 '0 213 245 0 0 0 0 1A-h1om 1.270 w 35.66 32.74 0 0 0 0 0 0 0 0 1A-hlom 1.270 w 35.56 32.74 0 0 0 0 ,- 0 0 0 0 C 16B30md 0.032 0.90 _ 1.68 105 105 94 176 127 127 113 213 F 22A3pl 0.989 27.69 , 0.00 0 0 1 0 0 0 1 0 6 c)AED excursion 38 - 37 Envelope'loss/gain 1432 1098 2094' 1410 12 a) Infiltration 227 62 261 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 01 1 0 Subtotal (lines 6 to 13) 1659 1160 2355 1481 Less eMemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1659 1160 2355 1481 15 Duct loads 19% 50% 321 584 19% 50% 4651 745 Total room load 1980 1744 2810 2226 Air required (cfm) 63 77 90 1 98 Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed. wrightsoft- Ri ht-Suite@ Universal 2012 12.0.07 RSU08101 2013-Jul-15 13:62:28 g Page 4 C3Users\Quick Calcs\Documents\Wrightsoft HVAC\FLOYD, KEVIN:rup Calc = MJ8 front Door faces: N +�+ wrightsoft, RigL2ti @ Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST.. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772466-6796 Emil: QUICKCALCS AOL.COM 1 Room name BATH 2 HAIL 2 Exposed wall 17.0 ft 38.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 11.0 x 6.0 ft 10.0 x 17.0 ft 5 Room area 66.0 ft2 170.0 ft2 Ty Constriction U-value Or HTM Area (ft') Load Area (ft-) Load number (Btuh/ft? °F) (Btu h/ft� or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 ludo 13A-4ocs 0.143 A 4.00 2.55 0 0 0 0 0 0 0- 0 II-----GG 1Aclom 1.270 n 35.56 17.90 -0 0 0 0 0 0 0 0 1A-hlomd 1.270 n 35.56 17.98 0 0 0 0 0 0 0 0 yJ 13A4ocs 0.143 a 4.00 2.55 48 39 156 99 88 88 352 224 11 1Afi1om 1.270 a 35.56 40.85 0 0 0 0 0 0 0 0 ILA-_CGGI 1"lom 1.270 a 35:56 40:85 9 0 320 368 0 0 0 0 1A-hlom 1.270 a 35.56 32.74 0 0 0 0 0 0 0 0 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1.270 se 35.56 27.28 0 0 0 0 0 0 0 0 1A-hlom 1.270 se 35.56 27.64 0 0 . 0 0 0 0 0 0 W 13A4ocs 0.143 s 4M 2.55 88 88 352 224 80 80 320 204 yyyyJJJJ 13A4ocs 0.143 w 4.00 2.55 0 0 0 0 136 ' 130 521 331 1A-hiom 1.270 w 35.56 40.85 0 0 0 0 6 0 213 245 IA-hlom 1.270 w 35.56 32.74 0 0 0 0 0 0 0 0 1A-h1om 1.270 w 35.56 32.74 0 0 0 0 0 0 0 0 C 161330md 0.032 0.90 1.68 66 66 59 111 170 170 152 286 F 22A-tpl 0.989 27.69 0.00 0 0 0 0 0 0 0 0 6 c)AM excursion 93 83 Envelope loss/gain 888 895 1559 1372 12 a) Infiltration 193 63 431 118 b) Room ventilation 0 0 0 0 13 internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1080 948 1989 1490 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1080 948 1989 1490 15 Duct loads 190/0 50% 209 477 19% 50% 385 750 Total room load 1289 1425 2374 2240 Air required (cfm) 41 63 76 99 Calculations approved bvACCA to meet all reaUirements of Manual J 8th Ed. 4+ - wrightsoftT 2013-Jul-15 13:52:28 RightSuite4� Universal 2012 12.0.07 RSU08101 Page 5 C:\Users\Quick Calcs\Documents\Wdghtsoft HVAC\FLOYD, KEVIN:rup Cale = MJ8 front Door faces: N