HomeMy WebLinkAboutEnergy Efficiency Code 5-21-13FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KEVIN FLOYD
Builder Name:
SsTeet: #921 VENTURE III
Permit Office:
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing
New (From Plans)
9. Wall Types (1558.0 sgft.)
Insulation Area
a'. Concrete Block - Ext Insul, Exterior
R=4.1 1558.00 ft2
2.:iingle family or multiple family
Single-family
b. N/A
R= ft2
3. Number of units, if multiple family •
1
c. N/A
R= ft2
4. Number of Bedrooms
2
d. N/A
10. Ceiling Types (1427.0 sgft.)
R= ftz
Insulation Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=38.0 1427.00 ft2
6. Conditioned floor area above grade (ft2)
1427
b. N/A
R= ft2 ;
ft2
c. WA
R=
ti
Conditioned floor area below grade (ft2)
0
11. Ducts
R fP
7. 'Nindows(321.5 sgft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Main
6 195
ri. U-Factor: Sgl, U=0.55
321.50 ft2
SHGC: SHGC=0.50
12. Cooling systems
kBtulhr Efficiency
b. U-Factor. NIA. �
ft2
a. Central Unit
19.2 SEER:16.00
SHGC:
u. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
10.796 ft.
Area Weighted Average SHGC:
0.500
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1427.0 sgft.)
Insulation Area
EF: 0.920
a. Slab -On -Grade Edge Insulation
R=0.0 1427.00 ft2
b. Conservation features
b. N/A
R= tt2
None
c. NIA
R= fI2
15. Credits
Total Proposed Modified Loads: 25.45
PASS
Glass/Floor Area: 0.225
Total Standard Reference Loads: 32.77
I hereby certify that the plans and specifications covered by
Review of the plans and
�TFiE ST9� ;
f0�,
this calculation are incompliance with the Florida Energy
specifications covered by this
calculation indicates compliance
y ,,, j� _ 41
'ice=:••
Code
;; il-
with the Florida Energy Code.
Before construction is completed
ti+" •- `=•?''
���..-<� !
PREPARE Y:
v
DATE:_K_
this building will be inspected for
compliance with Section 553.908
i :;+-i�o
°
I hereby certify that this building,. as. designed, is in compii ce
Florida Statutes.
f,I,COy�
ry
O wG
with the Florida EnergyCode.
OWNERIAGENT:
BUILDING OFFICIAL:
- 7-1 / 2
DATE:
DATE:
5/21/2013 8:57 AM EnergyGauge® USA - FlaRes2010, Section 405.4.1 Compliant Software Page 1 of 5
PROJECT
Tide:
KEVIN FLOYD
Bedrooms: 2
Address Type: Street Address
Building Type:
User
Conditioned Area: 1427
Lot #'
Block/SubDivision:
Owner:
Total Stories: 1
Worst Case: No
PlatBook:
# of Units:
1
Rotate Angle: 0
Street: #921 VENTURE III
Builder Name:
Cross Ventilation: No
County: ST. LUCIE COUNTY
Permit Office:
Whole House Fan: Yes
City, State, Zip: FT. PIERCE,
Jurisdiction:
FL,
Family Type:
Single-family
NewlE)Mng:
New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp Heating Design Daily Temp
/ Design Location
TMY Site Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture Range
FL,
Fort Pierce FL ST LUCIE_CO_INTL 2 39 90
70
75 722 62 Low
BLOCKS
rNumber
Name.
Area Volume
Blockl
1427 12843
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
1427 12843 Yes 4
2
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
Main 156 it 0
1427 ft2
0 0 1
ROOF
FRoof
Gable Roof
Solar
SA Emitt Emitt Deck Pitch
#
Type
Materials Area Area Color
Absor.
Tested Tested Insul. (deg)
1
Hip Composition shingles 1546 ft2 0 ft2 Medium 0.96
No 0.9 No 0 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300
1427 ft2
N N
CEILING
#
Ceiling Type
Space R-Value
Area
Framing Frac Truss Type
1
Under Attic (Vented)
Main 38
1427 ft�
0.11 Wood
5/2112013 8:57 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5
WALLS
Adjacent
Cavity Width
Height
Sheathing
Framing Solar
Below
1 i!
C)mt
To Wall
Space
Type p
R-Value Ft In
Ft In Area
R-Value
Eraction�lbso
1
N
-
Exterior Concrete Block - Ext Insul Main
4.09999 40
8 320.0 ft'
0
0 0.75
0
2
E
Exterior Concrete Block - Ext Insul Main
4.09999 51
9 459.0 ft2
0
0 0.75
0
3
S
Exterior Concrete Block - Ext Insul Main
4.09999 40
8 320.0 ft2
0
0 0.75
0
4
W
Exterior Concrete Block - Ext Insul Main
4.09999 51
9 459.0 ft'
0
0 0.75
0
DOORS
#
Omt
Door Type Space '
Storms
U-Value Ft
Width In
FHeight In
Area
1
S
Insulated Main
None
0.460000 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Omt_ ID Frame
Panes NFRC
U-Factor SHGC
Area Depth
Separation
Int Shade . Screening
1
N 1 Metal
Single (Tinted) Yes
0.55 0.5
128.0 ft' 12 ft 0 in
6 ft 0 in
Drapes/blinds
None
2
N 1 Metal
Single (Tinted) Yes
0.55 0.5
48.0 f12 10 ft 0 in
6 ft 0 in
Drapes/blinds
None
3
E 2 Metal
Single (Tinted) Yes
0.55 0.5
30.0 f12 10 ft 0 in
6 ft 0 in
Drapes/blinds
None
4
E 2 Metal
Single (Tinted) Yes
0.55 0.5
8.5 ft' 10 ft 0 in
6 ft 0 in
Drapes/blinds
None
5
E 2 Metal
Single (Tinted) Yes
0.55 0.5
9.0 ft' 10 ft 0 in
6 ft 0 in
Drapes/blinds
None
6
S 3 Metal
Single (Tinted) Yes
0.55 0.5
30.0 ft' 10 ft 0 in
6 ft 0 in
Drapes/blinds
None
7
S 3 Metal
Single (Tinted) Yes
0.55 0.5
6.0 f12 10 ft 0 in
6 ft 0 in
Drapes/blinds
None
8
W 4 Metal
Single (Tinted) Yes
0.55 0.5
32.0 ft' 10 ft 0 in
6 ft 0 in
Drapes/blinds
None
9
W 4 Metal
Single (Tinted) Yes
0.55 0.5
30.0 ft2 10 ft 0 in
6 ft 0 in
Drapes/blinds
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
308 f12
308 ft'
20 ft
9 ft
11
INFILTRATION
#
Scope
Method
SLA
CFM 50 ELA
EgLA ACH
ACH 50
1 Wholehouse Best Guess
0.000500
1871.52 102.744 193.225 0.36500
8.74338
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Block
Ducts
_
anvaliElectric Strip Heat None
COP: 1 27 kBtulhr
1
sys#1.
5121/2013 8:57 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5
COOLING SYSTEM
# System Type
Subtype _
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
_ (lnvaliCentral Unit
None
SEER: 16 19.2 kBtu/hr
576 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.92 40 gal.
50 gal
120 deg
None
SOLAR HOT WATER SYSTEM
77 FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model .# Area
Volume
FEF
None None
ft2
DUCTS
— Supply —
— Return —
Air
CFM25
HVAC #
# Location R Value Area
Location
Area Leakage Type
Handler CIM125 OUT QN
RLF
Heat Cool
Qnvali Attic
6 195 ft2
Attic
20 ft2 Default Leakage
Main
(invalid) cf (Default)
.1 1
TEMPERATURES
Frogramable Thermostat: Y
Ceiling Fans:
Cooling Jan ((]] Feb
Heating (X] Jan [X) Feb
Mar
Mar
[ ] Apr
[ ]Apr
May ri Jun rl Jul
May Jun Jul
Au
ri Au
Sep
rl Se
W Oct
Oct
Nov
Nov
H
((]] Dec
[X] Dec
Venting [[ ]] Jan [[ ]] Feb
X Mar
[Xl Apr
l Ma Jun Jul
L
Aug
Se
Oct
Nov
[[ 11 Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
PM
78
80
78 78
80 78
78 78 78
78 78 78
78
78
78 80
78 78
80
78
80
78
80
78
Cooling (WEH) AM
PM
78
78
78 78
78 78
78 78 78
78 78 78
78
78
78 78
78 78
78
78
78
78
78
78
Heating(WD) AM
PM
66
68
66 66
68 68
66 66 68
68 68 68
68
68
68 68
68 68
68
68
68
66
68
66
Heating (WEH) AM
PM
66
68
66 66
68 68
66 66 68
68 68 68
68
68
68 68
68 68
68
68
68
66
68
66
5/2M013 8:57 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
RPGidpritial Whole Buildina Performance Method
ADDRESS: #921 VENTURE III PERMIT #:
FT. PIERCE, FL,
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfmisq.ft. Testing or visual inspection required.
Fireplaces: gasketed doors & outdoor combustion air. Must complete
envelope leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating
controls
and cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies
in Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to =
R-2 + accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas..
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more.stages.
Ceilings/knee walls