HomeMy WebLinkAboutEnergy Efficiency Code 5-21-13FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KEVIN FLOYD Builder Name: SsTeet: #921 VENTURE III Permit Office: City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (1558.0 sgft.) Insulation Area a'. Concrete Block - Ext Insul, Exterior R=4.1 1558.00 ft2 2.:iingle family or multiple family Single-family b. N/A R= ft2 3. Number of units, if multiple family • 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A 10. Ceiling Types (1427.0 sgft.) R= ftz Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=38.0 1427.00 ft2 6. Conditioned floor area above grade (ft2) 1427 b. N/A R= ft2 ; ft2 c. WA R= ti Conditioned floor area below grade (ft2) 0 11. Ducts R fP 7. 'Nindows(321.5 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 195 ri. U-Factor: Sgl, U=0.55 321.50 ft2 SHGC: SHGC=0.50 12. Cooling systems kBtulhr Efficiency b. U-Factor. NIA. � ft2 a. Central Unit 19.2 SEER:16.00 SHGC: u. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 10.796 ft. Area Weighted Average SHGC: 0.500 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1427.0 sgft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 1427.00 ft2 b. Conservation features b. N/A R= tt2 None c. NIA R= fI2 15. Credits Total Proposed Modified Loads: 25.45 PASS Glass/Floor Area: 0.225 Total Standard Reference Loads: 32.77 I hereby certify that the plans and specifications covered by Review of the plans and �TFiE ST9� ; f0�, this calculation are incompliance with the Florida Energy specifications covered by this calculation indicates compliance y ,,, j� _ 41 'ice=:•• Code ;; il- with the Florida Energy Code. Before construction is completed ti+" •- `=•?'' ���..-<� ! PREPARE Y: v DATE:_K_ this building will be inspected for compliance with Section 553.908 i :;+-i�o ° I hereby certify that this building,. as. designed, is in compii ce Florida Statutes. f,I,COy� ry O wG with the Florida EnergyCode. OWNERIAGENT: BUILDING OFFICIAL: - 7-1 / 2 DATE: DATE: 5/21/2013 8:57 AM EnergyGauge® USA - FlaRes2010, Section 405.4.1 Compliant Software Page 1 of 5 PROJECT Tide: KEVIN FLOYD Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1427 Lot #' Block/SubDivision: Owner: Total Stories: 1 Worst Case: No PlatBook: # of Units: 1 Rotate Angle: 0 Street: #921 VENTURE III Builder Name: Cross Ventilation: No County: ST. LUCIE COUNTY Permit Office: Whole House Fan: Yes City, State, Zip: FT. PIERCE, Jurisdiction: FL, Family Type: Single-family NewlE)Mng: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp / Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS rNumber Name. Area Volume Blockl 1427 12843 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1427 12843 Yes 4 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 156 it 0 1427 ft2 0 0 1 ROOF FRoof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1546 ft2 0 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1427 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) Main 38 1427 ft� 0.11 Wood 5/2112013 8:57 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below 1 i! C)mt To Wall Space Type p R-Value Ft In Ft In Area R-Value Eraction�lbso 1 N - Exterior Concrete Block - Ext Insul Main 4.09999 40 8 320.0 ft' 0 0 0.75 0 2 E Exterior Concrete Block - Ext Insul Main 4.09999 51 9 459.0 ft2 0 0 0.75 0 3 S Exterior Concrete Block - Ext Insul Main 4.09999 40 8 320.0 ft2 0 0 0.75 0 4 W Exterior Concrete Block - Ext Insul Main 4.09999 51 9 459.0 ft' 0 0 0.75 0 DOORS # Omt Door Type Space ' Storms U-Value Ft Width In FHeight In Area 1 S Insulated Main None 0.460000 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Omt_ ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade . Screening 1 N 1 Metal Single (Tinted) Yes 0.55 0.5 128.0 ft' 12 ft 0 in 6 ft 0 in Drapes/blinds None 2 N 1 Metal Single (Tinted) Yes 0.55 0.5 48.0 f12 10 ft 0 in 6 ft 0 in Drapes/blinds None 3 E 2 Metal Single (Tinted) Yes 0.55 0.5 30.0 f12 10 ft 0 in 6 ft 0 in Drapes/blinds None 4 E 2 Metal Single (Tinted) Yes 0.55 0.5 8.5 ft' 10 ft 0 in 6 ft 0 in Drapes/blinds None 5 E 2 Metal Single (Tinted) Yes 0.55 0.5 9.0 ft' 10 ft 0 in 6 ft 0 in Drapes/blinds None 6 S 3 Metal Single (Tinted) Yes 0.55 0.5 30.0 ft' 10 ft 0 in 6 ft 0 in Drapes/blinds None 7 S 3 Metal Single (Tinted) Yes 0.55 0.5 6.0 f12 10 ft 0 in 6 ft 0 in Drapes/blinds None 8 W 4 Metal Single (Tinted) Yes 0.55 0.5 32.0 ft' 10 ft 0 in 6 ft 0 in Drapes/blinds None 9 W 4 Metal Single (Tinted) Yes 0.55 0.5 30.0 ft2 10 ft 0 in 6 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 308 f12 308 ft' 20 ft 9 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess 0.000500 1871.52 102.744 193.225 0.36500 8.74338 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts _ anvaliElectric Strip Heat None COP: 1 27 kBtulhr 1 sys#1. 5121/2013 8:57 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 COOLING SYSTEM # System Type Subtype _ Efficiency Capacity Air Flow SHR Block Ducts _ (lnvaliCentral Unit None SEER: 16 19.2 kBtu/hr 576 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 40 gal. 50 gal 120 deg None SOLAR HOT WATER SYSTEM 77 FSEC Collector Storage Cert # Company Name System Model # Collector Model .# Area Volume FEF None None ft2 DUCTS — Supply — — Return — Air CFM25 HVAC # # Location R Value Area Location Area Leakage Type Handler CIM125 OUT QN RLF Heat Cool Qnvali Attic 6 195 ft2 Attic 20 ft2 Default Leakage Main (invalid) cf (Default) .1 1 TEMPERATURES Frogramable Thermostat: Y Ceiling Fans: Cooling Jan ((]] Feb Heating (X] Jan [X) Feb Mar Mar [ ] Apr [ ]Apr May ri Jun rl Jul May Jun Jul Au ri Au Sep rl Se W Oct Oct Nov Nov H ((]] Dec [X] Dec Venting [[ ]] Jan [[ ]] Feb X Mar [Xl Apr l Ma Jun Jul L Aug Se Oct Nov [[ 11 Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 78 80 78 78 78 78 78 78 78 78 78 78 80 78 78 80 78 80 78 80 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM PM 66 68 66 66 68 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH) AM PM 66 68 66 66 68 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 5/2M013 8:57 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations RPGidpritial Whole Buildina Performance Method ADDRESS: #921 VENTURE III PERMIT #: FT. PIERCE, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfmisq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas.. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more.stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 5/21/2013 8:57 AM EnergyGauge@ USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5