Loading...
HomeMy WebLinkAboutEnergy Efficiency Code 7-19-13J FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KEVIN FLOYD Builder Name:0/111 4 ^ K t5i' A C-e tJ Street: #921 VENTURE III Permit Office: c. LV Cie- coup.*; I %t/ City, State, Zip: FT. PIERCE, FL, Permit Number: ! 3 t!�' 0 J z Owner: Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (1558.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a_ Concrete Block - Ext Insul, Exterior R=4.1 1558.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1427.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) 2 R=30.0 1427.00 ft . 6. Conditioned floor area above grade (ft2) 1427 b. NIA R= ft2 c. N/A R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(321.5 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 195 a. U-Factor: Sgl, U=0.55 321.50 ft2 SHGC: SHGC=0.50 ft2 12. Cooling systems kBtumr Efficiency b. U-Factor: N/A a_ Central Unit 19.2 SEER:16.00 SHGC: c. U-Factor: N/A ft, SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00, SHGC: Area Weighted Average Overhang Depth: 10.796 ft. Area Weighted Average SHGC: 0.500 14. Hot water systems a. Electric Cap: 40 gallons S. Floor Types (1427.0 sgft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 1427.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Area: 0.225 Total Proposed Modified Loads: 25.95 PASS Glass/Floor Total Standard Reference, Loads: 32.76 I hereby certify that the plans and specifications covered by Review of'the plans and ST42, _ °c�,0�' this calculation are in compliance with the Florida Energy specifications covered by this indicates �� ; Code. calculation with the Florida Energy Code. compliance51 tf gwP�i,'C, s' -,,,; .: y ' =A"'l o a 1: 3� l)_f .' _F°�' PREPARED -BY: ' 4 _} DATE: Before construction is completed p this building will be inspected for compliance with Section 553.908 �� •_e y� s •� I hereby certify that this building d,s I o lianc Florida Statutes. ` r �� ^OOWNER/AGENT: with the Florida Energ Xdig BUILDING OFFICIAL: DATE: %mil � DATE: 7/15/2013 1:54 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 r-'� PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/F)dsting: Comment: KEVIN FLOYD Bedrooms: 2 User Conditioned Area: 1427 Total Stories: 1 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: -No Whole House Fan: Yes Single-family New (From Plans) Address Type: Street Address Lot # Block/SubDivision: PlatBook: Street: #921 VENTURE III County: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, CLIMATE Design Location IECC Design Temp TMY Site Zone 97.5 % 2.6 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 1427 12843 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1427 12843 Yes 4 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 156 ft 0 1427 f' —_ 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Emid Deck Pitch Tested Tested Insul. (deg) 1 Hip Composition shingles 1546 ft= 0 ft2 Medium 0.96 No. 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1427 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 1427 ft2 0.11 Wood 7/15/2013 1:54 PM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 r ,\ WALLS Adjacent Cavity Width Height 'Sheathing Framing Solar Below Tn Wall TVnP Space R_VaILLP Ft In Ft In Qreg R-VA-le Fraction bsor_Grade? ' rot _ 1 N Exterior Concrete Block - Ext Insul Main 4.09999 40 8 320.0 ftz 0 0 0.75 . 0 _ 2 E Exterior Concrete Block - Ext Insul Main 4.09999 51 9 459.0 ftz 0 0 0.75 0 _ 3 S Exterior Concrete Block - Ext Insul Main 4.09999 40 8 320.0 ftz 0 0 0.75 0 4 W Exterior Concrete Block - Ext Insul Main 4.09999 51 9 459.0 ftz - 0 0 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated Main None .46 3 6 8 20 ftz_ WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Metal Single (Tinted) Yes 0.55 0.5 128.0 ftz 12 It 0 in 6 ft 0 in Drapes/blinds None 2 N 1 Metal Single (Tinted) Yes 0.55 0.5 48.0 ftz 10 it 0 in 6 ft 0 in Drapes/blinds None 3 E 2 Metal Single (Tinted) Yes 0.55 0.5 30.0 ftz 10 ft 0 in , 6 ft 0 in ' Dtapes/blinds None 4 E 2 Metal Single (Tinted) Yes. 0.55 6.5 8.5 ftz 10 ft 0 in 6 it 0 in Drapes/blinds None 5 E 2 Metal Single (Tinted) Yes 0.55 0.5 9.0 ftz 10 it 0 in 6 ft 0 in Drapesiblinds None 6 S 3 Metal Single (Tinted) Yes 0.55 0.5 30.0 ftz 10 ft 0 in 6 ft 0 in Drapesiblinds None 7 S 3 Metal Single (Tinted) Yes 0.55 0.5 6.0 ftz 10 ft 0 in 6 ft 0 in Drapesiblinds None 8 W 4 Metal Single (Tinted) Yes 0.55 0.5 32.0 ftz 10 ft 0 in 6 ft 0 in Drapes/blinds None 9 W 4 Metal Single (Tinted) Yes 0.55 0.5 30.0 ftz 10 ft 0 in 6 ft 0 in Drapesiblinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 308 it' 308 ftz 20 ft 9 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0005 1871.5 102.74 193.23 .365 8.7434 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 27 kBtuihr 1 sys#1 7/15/20131:54 PM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 L COOLING SYSTEM # System Type Subtype Efficiency Capacity _Air Flow SHR Block Ducts - I Central Unit None SEER: 16 19.2 kBtulhr 576 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 40 gal 50 gal 120 deg. None SOLAR HOT WATER SYSTEM FSEC Collector . Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None IF DUCTS — Supply — —Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 195 ftz Attic 20 ftz Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan [ ]Feb Heating Jan 1 Feb Mar Mar [ ] r j ] Apr W [ ] Ma [X Jun Jul [ ] MY j Jun 4 Jul [X] Au ] Aug [X] Se [ ] j ].S:p [ ] Oct Oct [ j Nov [X] Nov [ ] Dec [X] Dec Venting Jan [ ]Feb X Mar Apr [) Ma [ Jun [ Jul E J Au [ ] Se [X] Oct [X] Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 78 80 78 •78 78 78 78 78 78 78 78 78 80 78 78 80 78 80 78 80 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM PM 66 68 66 66 68 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (1NEH) AM PM 66 68 66 66 68 68 ,66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 7/15/20131:54 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 r FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: #921 VENTURE III PERMIT #: FT. PIERCE, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2.- Thermostat & 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation systems shall not exceed the minimum ASHRAE 62 level. ventilation No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 - HP shall have the capability of operating at two or more speeds. Spas & Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 7/15/2013 1:54 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5