HomeMy WebLinkAboutNotice of Acceptance (3) RECEIVED JUL 201,7 File Copy Wn DiADE MAMI-DADE COUNTY Z. PRODUCT CONTROL SECTION DEPARTMENT.OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street Room.208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.mlamidade.sovleconomy Sun-TekManufacturing,Inc. 10303 General Drive Orlando,FL 32824 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ)• This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance ptirposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing.and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ISFG Skylight System APPROVAL DOCUMENT: Drawing No. STI 00000298,titled"JUG",sheet 1 &2 of 2,prepared by Sun-Tek Manufacturing,Inc., dated August 07,2007, last revision#A dated May 04,2015, signed and sealed by James D. Wells, Jr., P.E., on May 04, 2015, bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and the expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series and the following statement; "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#13-1028.05 and consists of this page 1, evidence submitted pages E-1, E-2, &E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Helmy A.Makar,P.E.,M.S. CMIAMI�-DADECO=UN NOA No.15-0513.10 Expiration Date: 10/31/2018 Approval Date: 09/03/2015 oq Io3/ZoJ� Pagel sun Te1t1Y1an° � L,1n C. I NOTICE OF ACCEPTANCE:EVIDENCE SUBMTTED /VIDENCE SUBMITTED UNDER PREVIOUS APPROVAL 407-0425.04 1, /DRAWINGS A� 1. Drawing No. STI 00000298-SHTIISHT2, titled "ISFG", sheet 1 & 2 of 2, prepared / by Sun-Tek Manufacturing, Inc, dated 06104107 with last revision dated 08107107, ` signed and sealed by Tames D. Wells, Jr., P.E. l B. TESTS (submitted under NOA#02-0618.06) I 1. Test Report on Large Missile.Impact Test per PA 201, Cyclic Wind Pressure Test per % PA 203 and Uniform Static Air Pressure Test per PA 202 of"Insulated Glass Skylight / with Polycarbonate Inner Liner" prepared by National Certified Testing Laboratories, Report No. 210-2760-1, 2 & 3, dated 01122102, signed and sealed by A Portnoy,P.E. C. CALCULATIONS 1. Anchor Calculations for attachment.of skylight to curbing and curbing to decking, dated 08113107, signed and sealed by James D. Wells, Jr., P.E. i D. MATERIAL CERTIFICATIONS (submitted under NOA#02-0618.06) 1. Test report on Rate of Burning per ASTMD635 of Geon 87416 White 141 Exterior, 0.137 inch,prepared by Commercial Testing Company, Report No. 01- 11293, dated 11129101, signed by J.Jackson, 2. Test report on Self Ignition Temperature per ASTM D1929 of Geon 87416 White 141 Exterior,prepared by Commercial Testing Company, Report No. 01-11292, dated 11129101, signed by J. Jackson. E. STATEMENTS (submitted under NOA#02-0618.06) 1. Code compliance letter issued by Product Technology Corporation. on 09127102, signed and sealed by R. J. Quiroga P.E. F. OTHER 1. NOA renewal request letter issued by Sun-Tek Manufacturing, Inc., dated 08116107, James Feudner, 2. EVIDENCE SUBMTTED UNDER PREVIOUS APPROVAL 911-0601.02 A. DRAWINGS 1. Drawing No. STI-00000298 SIMISHT2, titled "ISFG", sheet I & 2 of 2, prepared by Sun-Tek Manufacturing, Inc, dated August 07, 2007, last revision #A dated October 14, 2011, signed and sealed by James D. Wells, Jr., P.E. eImy A..Makar,P.E.,M.S. Product Control Section Supervisor NOA,No.15-0513.10 Expiration Date: 1013112018 Approval Date: 09/03/2015 . E-1 I Sun-Te1c Manufacturing,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL 407-0425.04 A. DRAWINGS 1. Drawing No. STI-00000298-S=ISIIT2, titled "ISFG", sheet I & 2 of 2, prepared by Sun-Tek Manufacturing, Inc, dated 06104107 with last revision dated 08107107, signed and sealed by James D. Wells, Jr., P.E. B. TESTS (submitted under NOA#02-0618.06) 1. Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per PA 203 and Uniform Static Air Pressure Test per PA 202 of"Insulated Glass Skylight with Polycarbonate Inner Liner" prepared by National Certified Testing Laboratories, Report No. 210-2760-1, 2 & 3, dated 01122102, signed and sealed by B. Portnoy, P.E. C. CALCULATIONS 1. Anchor Calculations for attachment.of skylight to curbing and curbing to decking, dated 08113107, signed and sealed by James D. Wells, Jr., P.E. D. MATERIAL CERTIFICATIONS (submitted under NOA#02-0618.06) 1. Test report on Rate of Burning per ASTMD635 of Geon 87416 White 141 Exterior, 0.137 inch,prepared by Commercial Testing Company, Report No. 01- 11293, dated 11129101, signed by J. Jackson. 2. Test report on Self Ignition Temperature per ASTMD1929 of Geon 87416 White 141 Exterior,prepared by Commercial Testing Company, Report No. 01-11292, dated 11129101, signed by J. Jackson. E. STATEMENTS (submitted under NOA#02-0618.06) 1. Code compliance letter issued by Product Technology Corporation, on 09127102, signed and sealed by R. J. Quiroga P.E. F. OTHER 1. NOA renewal request letter issued by Sun-Tek Manufacturing, Inc., dated 08116107, James Feudner, 2. EVIDENCE SUBMTTED UNDER PREVIOUS APPROVAL#11-0601.02 A. DRAWINGS 1. Drawing No. STI-00000298-SHTIISHT2, titled `ISFG", sheet I & 2 of 2, prepared by Sun-Tek Manufacturing, Inc, dated August 07, 2007, last revision #A dated October 14, 2011, signed and sealed by James D. Wells, Jr., P.E. elmy A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No.15-0513.10 Expiration Date: 10/31/2018 Approval Date: 09/03/2015 E-1 Sun-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS 1. Test Addendum for Test Report NCTL 210-2760-1, prepared by national Certified Testing Laboratories, dated October 17, 2011, certifying the interlayer thickness, signed by Mark Bennett, Manager of Testing Services. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE -1. By Miami-Dade County Department of Permitting, Environment, and Regulatory Affairs(PERA). E. MATERIAL CERTIFICATIONS 1. None. 3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#12-1011.15 A. DRAWINGS 1. Drawing No. STI-00000298, titled "ISFG", sheet I & 2 of 2, prepared by Sun-Tek Manufacturing Inc, dated August 07, 2007, last revision #A dated May 03, 2012, signed and sealed by James D. Wells, Jr., P.E. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE I. By Miami-Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. OTHERS 1. A compliance letter,prepared by.J&L Wells Consulting LLC, dated April 25, 2012, certify compliance with FBC 2010 edition, sign&sealed by James D. Wells, Jr., P.E. 2. Verification testing to be performed per letter from National Certified Testing Laboratories, dated September 18, 2012, signed by Christopher Bennett. .Helmy A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No.15-0513.10 Expiration Date: 10/31/2018 Approval Date: 09/03/2015 E-2 . � s Sun-Tek Manufacturing,Inc. NOTICE OF ACCEPTANCE:EVIDENCE SUBMITTED 4. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#13-1028.05 A. DRAWINGS 1. ' Drawing No.' STI-00000298, titled "ISFG", sheet I & 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated August 07, 2007, last revision #A dated August 15, 2013, signed and sealed by James D. Wells, Jr., P.E., on February 07, 2014. B. TESTS 1. Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per PA 203 and Uniform.Static Air Pressure Test per PA 202 of"Insulated Glass Skylight -with Polycarbonate Inner Liner" prepared by National Certified Testing Laboratories, Report No. 210-3915-01, dated 0812712013, signed and sealed by Gerard Ferrara, P.E. C. CALCULATIONS 1. Anchor Calculations for attachment of skylight Model ISFG to Decking, dated 1010312013, signed and sealed by James D. Wells, Jr., P.E. D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. Bill of Material and Components Die Drawings. 5. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. STI-00000298, titled "ISFG", sheet 1 & 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated August 07, 2007, last revision #A dated May 04, 2015, signed and sealed by James D. Wells, Jr., P.E., on May 04, 2015. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami-Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. elmy A.Makar,P.E.,M.S. Product Control Section Supervisor NOA No. 15-0513.10 Expiration Date: 10/31/2018 Approval Date: 09/03/2015 E-3 .. t ti M PART NAME:ISFG SKYLIGHT ASSEMBLY FILE NAME:Z:\DWG\DWG\ACAD 2000 DRAWINGS\DADE COUNTY ISFG STI-00000298-SHT1 I SHEET 1 OF 2 DWG.NO.STI-00000298-SHT1 STI-215 DECO COVER 0.075 6063 T6 ALUM 17132"GLASS BITE 1/8"OUTBOARD DSB TEMPERED STI-214 DECO RING MITERED AND SILICONE BEDDING(CONTINUOUS) 1/8"INBOARD GLASS DSB TEMPERED WRAP AROUND 0.050 6063 T6 ALUM. STI-6 GLASS GASKET EPDM (CONTINUOUS) INSULATED AIR SPACE STI-205 CMG FRAME MITERED U) ARGON GAS FILLED AND WELDED 6063 T6 ALUM. LUM. STI-401 WOOD LINER 1.160.935" (CONTINUOUS) SWIGGLE SPACER(0. 5) 'A' \ I #8-32 PHILLIPS PAN HD SCREW AND HEX NUT 7 PER LONG SIDE 7 PER SHORT SIDE 177 POLYCARBONATE SHEET SILICONE SEAL TOP AND BOTTOM ' PALRAM PALSUN (CONTINUOUS) LLO a BUTYL 3 RINGS OF SEALANT STI-300 PVC LINER WELDED 0,075 SUB-FRAME3 T6 MITERED AND O BENEATH FLANGE(CONTINUOUS) GEON 87416 WHITE C�O AROUND PERIMETER OF FLANGE 141 EXTERIOR w (CONTINUOUS)AND ON TOP OF EACH vRODUcr REVISED z FLANGE SCREW Q AIR SPACE OR ae ild11%ad Hd h Oia Tlmte„ u. B�rildite c N DADE COUNTY APPROVED eNo -05 )o #8 X 1"PHILLIPS PAN HEAD SHINGLES EXPANDED POLYSTYRENE INSULATION nDa19SCREW, (9)PER S{DE (SEE NOTE 1) a u'contra ROOF DECK mina"thick U� I--- - DESIGN PRESSURE RATING+/-80 PSF. LARGE MISSILE IMPACT RESISTANCE Engineer of Record James D.Wells,Jr.,P.E. c \\ OAVIDW�s��/i Professional Engineer No.5361E NOTE: y `����'� ✓�*� . *(1)ALL ROOFING DETAILS SHALL COMPLY WITH o_ 0.53616 CHAPTER 15 OF THE FLORIDA BUILDING CODE 2014 edition �• J&L Wells Consulting LLC (2)4"MINIMUM DISTANCE FROM ANGLE LIP TO ROOF s0 SI 70It SURFACE IS FOR SHINGLE OR B.U.R.WITHOUT 1453 Arbitus Circle ~p^E%,� gs�c�TA��Ta$B`�or 1453A Oviedo, it 32765 INSULATION.FOR INSULATION AND TILE ROOF ADD TILE HEIGHT AND INSULATION THICKNESS TO 4". (407)496-5489 (3)ANCHORS TO BE MADE FROM NON-CORROSIVE MATERIAL Certificate of Authorization COMPATIBLE WITH ALUMINUM. RAFTER OR TRUSS NO.27162 (4)NO ONE-THIRD INCREASE IN THE DESIGN PRESSURE WAS USED. (5)TESTED TO TAS 201,TAS 202 AND TAS 203. REVISION: REVISION: PRODUCT NAME; REVISION MADE ON SHT.2 OF 2 ISFG SUN-TEK MANUFACTURING, INC. BY: BSD D T ' OBX07107 BY:jwf DATE: 8/15/2013 DRAWN BY: JWF DATE: 08/15/201 DWG. N0.STI 00000298-SHT1 REV. A 10303 GENERAL DRIVE ORLANDO,FL 32824 �l y n � PART NAME:ISFG SKYLIGHT PLAN VIEW FILE NAME:Z:\DWG\DWGIACAD 2000 DRAWINGS\DADE COUNTY ISFG STI-0000029E-SHT2 SHEET 2 OF 2 DWG.NO.STI-00000298-SHT2 54.5 STI-214 DECO RING MITERED AND WRAPPED tip to tip O AROUND 0.050 6063T6 ALUM 4•000 5.8125 4'000 0 SILICONE BEDDING(CONTINUOUS) STI-215 DECO COVER 0.0756063 T6 ALUM —5.8 25 5.8125 STI.6 GLASS GASKET EPDM OUTBOARD DSB TEMPERED 5, 1250. (CONTINUOUS) — --_ — STI-401 WOOD LINER SWIGGLE SPACER(0.625") — — (CONTINUOUS) STI-205 CMG FRAME 0.060 MITERED AND SULATED AIR SPACE 5.8125 WELDED CORNERS 6063 T6 ALUM _ARGON GAS FILLED #8-32 X i"PHILLIPS PAN HD SCREW Q I I ^ AND HEX NUT(7)PER SIDE INBOARD GLASS DSB TEMPERED SILICONE SEAL TOP FASTENERS SKYLIGHT AND BOTTOM(CONTINUOUS) TO DECK#8 X 1"(9)PER SIDE ^ .177 POLYCARSONATE SHEET O STI-207 HSF SUB-FRAME MITERED pALRAM PALSUN AND WELDED CORNERS 0.075 p a 6063 T6 ALUM I ISFG 4949 W O 3 RINGS OF BUTYL SEALANT AIR SPACE OR O w BENEATH FLANGE(CONTINUOUS) DADE COUNTY APPROVED I z Q AROUND PERIMETER OF FLANGE INSULATION SYME RICAL p n LL (CONTINUOUS)AND ON TOP OF EACH FLANGE SCREW STI-300 PVC LINER O 'v U) SHINGLES I I I I r (SEE NOT ♦\\\\,QpVDW�//// = FASTENERS SUB-FRAME TO FRAME #8 X 1"PHILPS PA .53616 SCREW(9)PER SIDE = min.protrusion IIT1 E OF r ROOF DECK"min thickness �i� jO<ORID� ♦�� RAFTER OR TRUSS FO111 AL,�'\\\♦♦` 4� 4"MININUM LIP TO FASTENER SCHEDULE SKYLIGHT TO DECK FASTENER SCHEUL DE 00 ROOF SURFACE A #8 X 1"PAN HEAD SUB-FRAME TO FRAME SCREWS #8-32 X 3/4"WITH HEX NUTS �t DESIGN PRESSURE RATING+/-80 pSF. O tip to tip MODEL PER PER PER PERLONG SIDE SHORT SIDE LONG SIDE SHORT SIDE LARGE MISSILE IMPACT RESISTANCE N Engineer of Record 54.5x54.5 4949 9 9 7 7 NOTE: James D.Wells, Jr.,P.E. 51.sxst.s 4646 8 8 7 7 * Professional Engineer No 53616 3as53as 33 (1)ALL ROOFING DETAILS SHALL COMPLY WITH roesson . � S 3333 6 7 5 49 9 6 6 5 5 CHAPTER 15 OF THE FLORIDA BUILDING CODE 2014 edition PRODuCI REVISED 35.561.5 3046 8 s 7 5 2 4"MINIMUM DISTANCE FROM ANGLE LIP TO ROOF W�Pl,q°g with ltwFl°nda 35.905.5 3030 6 6 5 5 ( ) D°ildi°g Cale SURFACE IS FOR SHINGLE OR B.U.R.WITHOUT A ��N° - 3.1° J&L Wells Consulting LLC 3oss z5a9 s 5 7 a oD'd° �s a'18 1453 Arbitus Circle �• 2533 6 5 5 4 INSULATION.FOR INSULATION AND TILE ROOF ADD 30.s:305 2525 5 5 4 4 TILE HEIGHT AND INSULATION THICKNESS TO 4", Mc°n°°. Oviedo, Fl.32765 27.9x5t.5 2246 8 5 7 4 (3)ANCHORS TO BE MADE FROM NON-CORROSIVE MATERIAL (407)496-5489 27.5,ct5.5 2230 6 5 5 4 COMPATIBLE WITH ALUMINUM. 27.547.5 2222 5 5 4 4 (4)NO ONE-THIRD INCREASE IN THE DESIGN PRESSURE WAS USED. Certificate Of Authorization 22.sxsa.S 1733 9 4 7 3 22.5:3e. (5)TESTED TO TAS 201,TAS 202 AND TAS 203. No.27162 17 6 4 5 3 te.sXst.s 1448 8 4 7 3 19.9a35.5 1430 6 L 4 1 5 3 REVISION: REVISION: PRODUCT NAME: ISFG SUN-TEK MANUFACTURING, INC. BY: JWF DATE: 08/19/13 BY: DATE: DRAWN BY: JWF I DATE: 10/14/201 DWG.NO.STI-00000298-SHT2 REV. A 10303 GENERAL DRIVE ORLANDO,FL 32824