HomeMy WebLinkAboutInstallation Instructions Foundation,Pan & ConcreteOLIVER TECHNOLOGIES, .INC.
INSTALLATION INSTRUCTIONS FOR FLORIDA
AA AA scx m r%r-nor—o% . ■ . .....�-- --- -- -- - -- — - -
PATENT # 6634150 & OTHER PATENT PEN
J6a COD'
1
page 1
OLIVER TECHNOLOGIES, INC. revision 6/07
FLORIDA INSTALLATION INSTRUCTIONS FOR THE
MODEL 1101 "V" SERIES ALL STEEL FOUNDATION SYSTEM
MODEL 1101"V" (STEPS 1-15)
LONGITUDINAL ONLY.• FOLLOW STEPS 1-9
FOR ADDING LATERAL ARM: Follow Steps 10-15
FOR CONCRETE APPLICATIONS: Follow Steps 16-19
ENGINEERSSTAMP ENGINEERS STAMP
1. SPECIAL CIRCUMSTANCES: If the following conditions occur - STOP! Contact Oliver Technologies at 1-800-284-7437 :
a) Pier height exceeds 48" b) Length of home exceeds 76' c) Roof eaves exceed 16" d) Sidewall height exceed 96"
e) Location is within 1500 feet of coast
INSTALLATION OF GROUND PAN
2. Remove weeds avid debris in an approximate two foot square to expose firm soil for each ground pan (C) .
3. Place ground pan (C) directly below chassis I-beam . Press or drive pan firmly into soil until flush with or below soil.
SPECIAL NOTE: The longitudinal "V" brace system serves as a pier under the home and should be loaded as any
other pier. It is recommended that after leveling piers, and one-third inch (1/3") before home is lowered completely on.
to piers, complete steps 4 through 9 below then remove jacks.
INSTALLATION OF LONGITUDINAL "V" BRACE SYSTEM
NOTE: WHEN INSTALLING THE LONGITUDINAL SYSTEM ONLY, A MINIMUM OF 2 SYSTEMS PER FLOOR SECTION IS REQUIRED. SOIL TEST
PROBE SHOULD BE USED TO DETERMINE CORRECT TYPE OF ANCHOR PER SOIL CLASSIFICATION. IF PROBE TEST READINGS ARE BETWEEN
175 & 275 A 5 FOOT ANCHOR MUST BE USED. IF PROBE TEST READINGS ARE BETWEEN 276 & 350 A 4 FOOT ANCHOR MAY BE USED. USE
GROUND ANCHORS WITH DIAGONAL TIES AND STABILIZER PLATES EVERY 5W' . VERTICAL TIES ARE ALSO REQUIRED ON HOMES SUPPLIED
WITH VERTICAL TIE CONNECTION POINTS (PER FLORIDA REG.) .
4. Select the correct square tube brace (E) length for set - up (pier) height at support location. (The 18" tube is always
used as the bottom part of the longitudinal arm). Note: Either tube can be used by itself, cut and drilled to length as long as a
40 to 45 degree angle is maintained.
PIER HEIGHT 1.25" ADJUSTABLE 1.50" ADJUSTABLE
(Approx. 45 degrees Max.) Tube Length Tube Length
:+q a3rr,�r♦r,��C7'�"�$;�ai x �r s ;+ka's"yys °"�s
Nr.
24 3/4" to 32 1 /4" 32" 1811
40" to 48" 54" 18"
5. Install (2) of the 1.50" square tubes (E (18" tube) ) into the "U" bracket (J), insert carriage bolt and leave nut loose for final
adjustment.
6. Place I-beam connector (F) loosely on the bottom flange of the I-beam.
7. Slide the selected 1.25" tube (E) into a 1.50" tube (E) and attach to I-beam connectors (F) and fasten loosely with bolt and nut.
8. Repeat steps 6 through 7 to create the 'Y pattern of the square tubes loosely in place. The angle is not to exceed 45
degree and not below 40 degrees.
9. After all bolts are tightened, secure 1:25" and 1.50" tubes using four(4) 1/4"A4 x 3/4" self -tapping screws in pre -drilled holes.
INSTALLATION OF LATERAL TELESCOPING TRANSVERSE ARM SYSTEM
THE MODEL 1101 "V" (LONGITUDINAL & LATERAL PROTECTION) ELIMINATES THE NEED FOR MOST STABILIZER PLATES & FRAME TIES.
NOTE: THE USE OF THIS SYSTEM REQUIRES VERTICAL TIES SPACED AT 51".
FOUR FOOT (4') GROUND ANCHOR MAY BE USED EXCEPT WHERE THE HOME MANUFACTURER SPECIFIES DIFFERENT.
10. Install remaining vertical tie -down straps and 4' ground anchors per home manufacturer's instructions. NOTE: Centerline
anchors to be sized according to soil torque condition. Any manufacturer's specifications for sidewall anchor loads in excess of
4,000 lbs. require a V anchor per Florida Code.
11. NOTE: Each system is required to have a frame tie and stabilizer attached at each lateral arm stabilizing location. This frame tie &
stabilizer plate needs to be located within 18" from of center ground pan. -
12. Select the -correct square tube brace (H) length for set-up lateral transverse at support location. The lengths come in either 60"
or72" lengths. (With the 1.50" tube as the bottom tube, and the 1.25" tube as the inserted tube.)
13. Install the 1.50 transverse brace (H) to the ground pan connector (D) with bolt and nut.
14. Slide 1.25" transverse brace into the 1.50" brace and attach to adjacent I-beam connector ( I ) with bolt and nut.
15. Secure 1.50" transverse arm to 1.25" transverse arm using four (4) 1/4" - 14 x 3/4" self-taDDina screws in Dre-drilled holes.
OLIVER TECHNOLOGIES, INC. Telephone: 931-796-4555
1-800.284-7437 Fax: 931-796-8811
www.alivertechnalogies.com
page 2
INSTALLATION USING CONCRETE RUNNER I FOOTER revision 6/07
1'6. A concrete runner, footer or slab may be used in place of the steel ground pan.
a) The concrete shall be minimum 2500 psi mix
b) A concrete runner may be either longitudinal or transverse, and must be a minimum of 8" deep with a minimum width of 16 inches
longitudinally or 18 inches transverse to allow proper distance between the concrete bolt and the edge of the concrete (see below).
c) Footers must have minimum surface area of 441 sq. in. (i.e. 21" square), and must be a minimum of 8" deep.
d) If a full slab is used, the depth must be a 4" minimum at system bracket location, all other specifications must be per local jurisdiction.
Special inspection of the system bracket installation is not required.. Footers must allow for at least 4" from the concrete bolt to the edge
of the concrete.
NOTE: The bottom of all footings, pads, slabs and runners must be per local jurisdiction.
LONGITUDINAL: (Model 1101 LC "V")
17. When using Part # 1101-W-CPCA (wetset). imply install the bracket in runner/footer OR When installing in cured concrete use Part #
101-D-CPCA (drvset). The 1101 (dryset) CA bracket is attached to the concrete using (2) 5/8"x3" concrete wedge bolts (Simpson part #
S162300H 5/8" X 3" or Powers equivalent). Place the CA bracket in desired location. Mark bolt hole locations, then using a 5/8" diameter
masonry bit, drill a hole to a minimum depth of 3". Make sure all dust and concrete is blown out of the holes. Place wedge bolts into drilled
holes, then place 1101 (dry set) CA bracket onto wedge bolts and start wedge bolt nuts. Take a hammer and lightly drive the wedge bolts
down by hitting the nut (making sure not to hit the top of threads on bolt). The sleeve of concrete wedge bolt needs to be at or below the top
of concrete. Complete by tightening nuts.
LATERAL: (Model 1101 TC "V")
18. For wet set (part # 1101-W-TACA) installation simply install the anchor bolt into runner/footer. For dry set installation (part ,# 1101-D-TACA)
mark bolt hole locations, then using a 5/8" diam. masonry bit, drill a hole to a minimum depth of 3". Make sure all dust and concrete is
blown out of the hole. Place wedge bolts (Simpson part #S162300H 5/8" X 3" or Powers equivalent) into (D) concrete dry transverse
connector and into drilled hole. If needed, take a hammer and lightly drive the wedge bolts down by hitting the nut (making sure not to hit
the top of threads on bolt), then remove the nut. The sleeve of concrete wedge bolt needs to be at or below the top of concrete
19. When using part # 1101 CVW (wetset) or 1101 CVD (dryset), install per steps 17 & 18.
Notes:
1. LENGTH OF HOUSE IS THE ACTUAL BOX SIZE
2. • = STABILIZERR PLATEAND FRAMETIE LOCATION (needs b
be bc&d mft 18 hches of oal3rof gxrld pan or oonaeb)
3. C� LOCATION OF LONGITUDINALBRAGNG ONLY
4. ga- TRANSVERSE & LONGf f UDINAL LOCATIONS
REQUIRED NUMBER AND LOCATION OF MODEL 1101 "V" OR 1101 C "V"
ALL WIDTHS; AND LENGTHS UP TO 52'
it
IIII
i'
i
I�I
S
ALL WIDTHS; AND LENGTHS OVER 52' TO 80'
•
•
•
•
•
t -
Florida approved 4' ground
anchors may be used in all
locations except where
home manufacturers speck
fications for sidewall straps
are in excess of 4,000 lbs.
These locations require a 5'
anchor. Per Florida Code.
D -Ground
Pan
transverse
connectors
Longitude dry
concrete bracket
part # 1101 D-CPCA
Wet bracket part #
1101 W-CPCA not
shown
Ida approved 4' ground
hors may be used In all
lions except where home
iufacturers specifications
>idewall straps are In
ass of 4,000 lbs. These
itions require a V anchor.
Florida Code.
I - Transverse arm I-beam
connector I -
<H - Transversearm
Top (
bottomm (1. (1.5" )
E - "V" Brace Tub
Top (1.25")
Bottom (1.5")
- Ground Pan
U bracket
F- :"V" brace I-beam t
connectors
J - ground Pan
V Bracket
page 3
revision 6/07'
C = GROUND PAN
D = GROUND PAN CONNECTOR
U BRACKETS TRANSVERSE
E = TELESCOPING V BRACE
TUBE ASSEMBLY W/ 1.5 BOT-
TOM TUBE AND 1.25 TUBE
INSERT
F = "V" BRACE I -BEAM CONNEC-
TORS ASSEMBLY
H = TELESCOPING TRANSVERSE
ARM ASSEMBLY
I = TRANSVERSE ARM I -BEAM
CONNECTOR
J= V PAN BRACKET
Model # 1101 " V"
Alternate Hole for
Narrower Beam Flange
Grade 5 -.1/2" x 1"
Carriage Bolt & Nut
Grade 5 -1/2" x 2 1/2"
Carriage Bolt & Nut
I -BEAM CONNECTOR BRACKET
I - Transverse arm I-beam
connector — -
<H Transverse arm
Top (1.25")
i bottom
Tub
1.5")
F-
connectors
\Y/
J - Concrete
�- "V" Bracket
Model 1101 CVD
Model 1101 CVw
not shown
C = CONCRETE FOOTER/RUNNER
D = CONCRETE U BRACKET TRANSVERSE
CONNECTOR (connects with grade 5 -1/2" x 2
i 1/2"" carriage bolt & nut)
+� E = TELESCOPING V BRACE
TUBE ASSEMBLY W/ 1.5 BOT-
TOM TUBE AND 1.25 TUBE
INSERT
F = "V" BRACE I -BEAM CONNECTOR ASSEMBLY
(connects with grade 5 - 1/2" x 4" carriage bolt
& nut)
H = TELESCOPING TRANSVERSE ARM
ASSEMBLY
I = TRANSVERSE ARM I -BEAM CONNECTOR
(connects with grade 5 -112" x 2112"" carriage bolt
& nut)
J= CONCRETE "V" BRACKET (connects with
grade 5 - 1/2" x 4" carriage bolt & nut)
- Concrete
Footed Runner
Model # 1101 C "V"
OLIVER TECHNOLOGIES, INC. Telephone: 931-796-4555
1-800.284-7437 Fax: 931-796-8811