Loading...
HomeMy WebLinkAboutSet-Up Manual AddendumSET-UP MANUAL ADDENDUM ❑ter❑ jAqOBS N HOMES •11 PACKARD COFUF SAFETY HARBOR, FLORIDA (727) 726-1138 NOTICE These specifications and drawings are original, proprietary, and confidential materials of Jacobsen Manufacturing, Inc. Such materials are provided to the recipient for specific purposes and must be kept confidential and secret from others. 6/1 /07 ALL HOMES SET IN FLORIDA MUST COMPLY WITH DMV RULE 15C EFFECTIVE MARCH 29,1999 For information on 15C- contact the Department of Motor Vehicles 850-413-7600 0� NOTES: ADDENDUM EXTERIOR HEATING/COOLING DUCT DUE TO THE NEW THERMAL REQUIREMENTS INSTITUTED BY HUD, THE INSULATION VALUES OF THE MANUFACTURED HOME HAVE INCREASED. IT IS NOW NECESSARY FOR ALL EXTERIOR DUCTS INSTALLED ON JACOBSEN HOMES HAVE A MINIMUM R-VALUE OF B. ALL HEATING AND/OR COOLING SUPPLY AND RETURN DUCTS EXPOSED DIRECTLY TO THE OUTSIDE AIR, SUCH AS UNDER CHASSIS CROSSOVER DUCTS OR DUCTS CONNECTING EXTERNAL HEATING, COOLING OR COMBINATION HEATING/COOLING APPLIANCES SHALL BE INSULATED WITH MATERIAL HAVING A MINIMUM THERMAL RESITANCE OF R=8.0. WITH A CONTINUOUS VAPOR BARRIER HAVING A PERM RATING OF NOT MORE THAN 1 PERM. WHERE EXPOSED UNDERNEATH THE MANUFACTURED HOME, THE DUCT SHALL NOT BE IN CONTACT WITH THE GROUND, /DUCT SUPPLY OR RETURN OOUNG 3SOVER USE MINIMAL AMOUNT OF DUCT. LIMIT DUCT USAGE TO REDUCE THE AMOUT OF BTU, iDUR LOSS. DO NOT OVER BEND OR CRIMP FLEX DUCT, THIS WILL RESTRICT THE AMOUNT OF AIR FLOW THROUGH THE DUCT. USE STRAPPING OR OTHER MEANS OF SUPPORT TO PREVENT THE DUCT FROM COMING IN CONTACT WITH THE GROUND. PLACE STRAPS AS NEEDED TO SUPPORT DUCT (DO NOT RESTICT AIR FLOW BY OVER TIGHTENING SUPPORT STRAPS). ALSO SEE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR DUCT INSTALLATION AND SUPPORT. DANA APPROVAL 'PROVED BY 0 oor 4JlM 1 5 W fl INC JACOBSEN HOMES NOTICE DRAWN BY: ' C.L.Y. °ATEc 5=30-95V`E� THESE SPECYIGTIOHS AND DRAWINGS ARE ORIGINAL, PROPRIETARY. AND CON11DEmnAL DRAWING 71T1E: MATERIALS OF JACOBSEN MANUFAC7"G P.O. BOX 368 INC. SUCN YAIERULS ARE FRONDED TO THE EXTERIOR A/C DUCT SAFETY HARBOR. FLORIDA 34695 RECPENT FCR SKCFIC FL@F 0 AND IAIST BE DRAWWG NUMBER: PHONE (813) 726-1138 IVT MWOCHTIAL Aw SEDU RROY ORQ6 AD-AC-0001 3 ADDENDUM WHOLE HOUSE VENTILATION SYSTEM YOUR HOME HAS BEEN EQUIPPED WITH A 'WHOLE HOUSE' VENTILATION SYSTEM. THIS SYSTEM HAS BEEN DESIGNED TO MEET ALL THE REQUIREMENTS SET FORTH BY THE UNITED.STATES DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT. THE WHOLE HOUSE VENTILATION SYSTEM IS REQUIRED (BY HUD) TO EXCHANGE AIR DIRECTLY WITH THE EXTERIOR OF THE HOME. THE PURPOSE OF THIS SYSTEM IS TO GIVE THE HOME OWNER THE ABILITY TO INTRODUCE FRESH OUTSIDE AIR INTO THE INTERIOR OF THE MANUFACTURED HOME, INSTEAD OF SIMPLY RE— CIRCULATING THE SAME OLD, STALE AIR THROUGHOUT THE HOME, THUS IMPROVING THE INDOOR AIR QUALITY. THE SYSTEM INSTALLED IN YOUR HOME HAS BEEN DESIGNED TO GIVE YOU COMPLETE CONTROL OF WHEN AND HOW THIS SYSTEM IS USED. YOUR HOME IS EQUIPPED WITH A FAN THAT WILL EXHAUST STALE INDOOR AIR (TO THE EXTERIOR OF THE HOME). THIS FAN IS SWITCH CONTROLLED AND MAY BE MANUALLY OPERATED. TO DIsCCNTIP•IUE USE OF THIS SYSTEM, SIMPLY 'TURN OFF' THE SWITCH THAT CONTROLS THE FAN. NOTICE TO HOMEOWNER Whole house ventilation switch You will be able to locate the switch that controls this fan by locating the switch that is labeled -WHOLE HOUSE VENTILATION. (See AD-AC-0100) NOTES- DMA APPROVAL: APPROVED BY C100 00�'r " INC. wa NOTICE: DRAWN BY., DATE: REV. LETTER: C1Ci JACOBSEN HOMES THESE SPECIT1ExnONs AND DRAVANGS ARE C.L.Y. 9-28-95 ,IO W.H. N SYS. CRIONAL. PROPRIETARY, AND DONFIDENTIAL DRAWING TITLE: P.O. BOX 368 B MATERIALS OF JACOBSEN YANUFACIMNC INC. SUCH YATEPJALS ARE PROY.DED 10 THE SAFETY HARBOR, FLORIDA 34695 RECPQJT FOR SKCFIC PURPOSES AND WST BE DRAWING NUMBER PHONE (813) 726-1138 OUT CWDDITUL AND SEWT FROM OTHERS. AD—AC-0100 4 ADDENDUM MULTI -WIDE UNIT FLOOR FASTENING FLOOR JOIST 0.131" X 1 1 /2' MIN. 3/8' X 3 1 /2' MIN. LAG INSTALLED SEE NAILS OR 7/16' X 16 GA. CHART FOR MAXIMUM SPACING, STAGGERED STAPLES PER TABLE: FROM SIDE TO SIDE AT AN APPROX. 45' ANGLE FROM VERTICAL. SEE DETAIL BELOW IF GAP EXISTS BETWEEN FLOORS. 0.016' X 1 1/2' MIN. STEEL STRAP ® 48' O.C. MAX. SPACING 1 4" TO 3 4' GAP WITH FASTENING INTO JOIST EACH SIDE OF CENTER LINE PER TABLE BELOW: FOR GAPS IN FLOOR SYSTEMS INSTALL WOOD SHIM AT ALL LAG TO 1/2', INCREASE LAG LENGTH 1' LOCATIONS FOR LAG SCREW TO GO ' NDS01 AND FOR GAPS TO 3AG INCREASE THROUGH AND TO KEEP CONNECTION EASE (ALL ZONES) LAG LENGTH 1 TIGHT. (SEE NOTE 2) (ALL EFOSURES) MILD Z01E MOM 3/r X 3 1/2' LAG S17IEW 30 GA. SIRUP FAST00 W/ 7/I1' 116 GA. sTAgm we 20NE EXPORK WIR111 NLWIBM OF FASMARS REQI M 0.131' X 1 1/Y' NAMS 7/16' X 15 GA SWIM MAX" SPACNG NAMW SPACING .� IV O.C. 21/4' QC. 3 S 2 2 V 17' at 1 7/!r aC ti• 4 7 'O' 16' O.C. 2' aC 'C' 4 7 3 3 b' W aC 1 1/2' aC. V i 1 e NOTES ENMW APPROVAL• CAM APPRO'VAI: APPROVED BY 1. 1' MK FUMAna1 6 REQU O ON STAAM FOR UK a01f' STRAP. Revised .r 23 _07b L WOW SHW6 70 BE RPPED FROM SPF #3 UK OR BETTER. (3' 4' X CAP IND1H IAK gal May 24,2006 IF 0m OR PLywm YAY K USED Rcum EOUAIS GAP vmTH-4' X 4' 1QE 3V John C. LjbA en, P !=.7NAINC. 3 IOC YAXURJII SMALL NOW. r � !0. ETT(33iioori 1(g, :�iu FEDEML MANUFACTURED MOIRE CONSTRUCTION AND SAFETY STANDARDS 4. SEE CUB KW Fri SEAL4IG FLOORS FOR AIR N1LWIATl011 JACOBSEN HOMES nsg scar N0>las ,=,,,o MAW BY. GAiE 05-22-06 REV. tETiER P.a eox 3ca arAWK. PWWAV AM NWAC llea Iw,E>�Ks a �"°°dg" ""`r"cluw'D uuWac nTIE: M/W FLOOR FASTENING SAFETY NE (81 , FLORN)A 34695 PHONE (813) 726-1138 �ii Mi $ C FO►o6c Y�lST R an cor>mluL me SET "A ORE11S DFUWNG NUYBf7t AD—FA-00�1 ADDENDUM MULTI -WIDE UNIT WALL FASTENING ENDWALL NDS01 1. FASTENING REQUIRED ONLY AT MARRIAGE LINE OF EXTERIOR WALLS. .131- X 3 1/2- MIN. NAILS 8' O.C. MAX. SPACING, STAGGERED FROM SIDE TO SIDE (TOE -NAILED). MARRIAGE LINE aGKO APMAU S 2� ob John C. Dueden, P.L-. K2 Eng- mering. Ina. APPROVED BY Revised May 24,2006 I0 golo FEDEOIL !IwANC. WED HOME CONSTNUCfIpI AND SIiFETY ST�IID�RDS ElEmEl DirclMG JACOBSEN HOMES P.O. BOx m SAFETY HARBOR. FLOWA 34695 PHONE (513) 726-1138 -*m r m=na ma aawm Aac 0140VA. FROPI� UL AID �iLOIML annu °F otem """'rA�am 3= VAINU ARE FROMM 10 M ®ort FOR PJAPOM 010IM t wt mmK mm enm =a Olmm m or. M.T. YAIC 05-22-06 DLL ELIILJG B m1m 11M. M/W WALL FASTENING DRAWNG NOYE*R AD-FA 6 ADDENDUM MULTI -WIDE ROOF FASTENING l� CENTER LINE OR MATING �. LINE OF TRIPLE WIDE UNITS 30 'GA. GALV. STEEL STRIP I SECURED VNTH 7/16' X 16 GA. STAPLES FULL PENETRATION INTO DECKING (SEE CHART ON AD-FA-0001 MAX SPACING). 30 GA. GALV. STEEL STRIP "S' X LENGTH OF ROOF (SECTIONS MAY BE OVERLAPPED 2' MIN.) W/STAPLES AS SHOWN. INSTALL ROOF CAP PER SET- UP MAN. OVER GAL STRIP. I (30 GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS REMOVED FROM -IAG SCREW SET RACKS ROOF IN ORIGINAL CONDITION, FOR TRIPLE WIDES EXCEPT FOR STAPLE HOLES.) FOR DOUBLE WIIOES�\ PLAN VIEW 1 4' 2 3 4' 3/5- X 5' LAG SCREWS •• AG SCREW SET BACKS TRIPLE WDE ROOF UNE (2 1/4' SMOOTH SHANK) FOR DOUBLE W1DES I I� SEE CHART ON SPACING FOR TRIPLE WOES SPACING INSTALL LAG SCREWS � -� FOR MAXIMUM AT A 45' ANGLE - 42 1 4 2 3�4r* STAGGERED 14TO3'GAP _ ROOF PERIMETER RAIL—` OR RIDGE BEAM (FOR RIDGE BEAMS SEE NOTE J4) CROSS-SECTION J �-- INSTALL WOOD SHIM AT ALL LAG FOR GAPS IN ROOF SYSTEMS LOCATIONS FOR LAG SCREW TO GO TO 1/2', INCREASE LAG LENGTH 1' THROUGH AND TO KEEP CONNECTION AND FOR GAPS TO 3/4, INCREASE TIGHT. (SEE NOTE 2) NDS01 LAG LENGTH 1 1/2'. REF CAL.C. PG. (ALL ZONES) CROSS-SECTION (W/GAP-), C WA- 91.01- 91.07 (ALL EXPOSURES) NOTES: -- - OWEER APPROVAL: DARA APPROVAL: L 2 1/C YIN. PEREIRATION N10 RECUMHG MEMBER IS RE"IED FOR LAC SGHEYfS. 2 WOOD SIM TD_BE RAPED FROM SPF P UK OR KTFUL APPROVED BY �3- X C X CAP WMDTH UK SM) Revised 0® OR PLYNOOD MAY B: USED F I NMEM EOUAIS GAP MD1 4 X C MR SHIE) / 3. SIT GM OETALS FOR CM PIJ:TIHG ROOF NTEKCTOL (Q All aY 24,2006 4. *0 NST1U M A LAG SCREW NR1 A RM B.AK FFST-dtLL A 3/8. OF*MM �gilfl�i. IJ06QeF1. P ti .INC. HCIE THROUGH TIC FIRST RIDGE BEA1L XM -ffU A 1/4' HOM MUCH M 1l? E:.flgi119Ern Tq, Inc FEDERAL NMUFACTURED HOME RECOM WCE BEAM FOR TNE WADED PCRTO OF LAC S THESE DNS AM CONSTRUCTION AND SAFETY STANDARDS FOR 3/r LAC SCRM ONLY S We MUMUM SNEMAIL HEIGHT. JACOBSEN HOMES NO11 1FiS'i SiCixJl1Kf6 AM AND DRAr+cs Ali awfw' rRa9e my. " OM#Ixh K wxm w Ahem a VANWACTURIC °RAMN BY' M.T. DAZE' 05-22-06 my. �"u` MAY" TIM M%W ROOF FASTENING \I P.O. BOX 365 !I- an YATFAWS ARE MD+E7m TD I E °RA"Nc "" AD-FA-0020 SAFtIY PHHONE {(813) 726-113D��. a"emproml mEm"mwnPAWD om� 7 ADDENDUM MULTI=WIDE ROOF SEALING/CLOSE-UP MIN. 30 GA. GAIV. STEEL STRAPPING \ (SEE AD-FA-0020) 6" STRIP ROOFING CEMENT RECOMMENDED OVER EDGES I NOTES: 1. 30 GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS REMOVED FROM ROOF IN ORIGINAL CONDITION (EXCEPT FOR STAPLE HOLES). 15# FELT UNDERLAYMENT MULTI -WIDE ROOF LINE BEAD OF ROOFING CEMENT RECOMMENDED EACH SIDE PROVED BY JA 1 5 19m INC NOnCa DRAWN BY: DAIS: REV. LETTER: JACOBSEN HOMES THESE SPEoncAnats AND DRAWINS ARE C.L.Y. 6-5-95 OMONAL PROPPoEUHY. AND Wemm DRAWING ITL£ M�YV ROOF SEALING P.O. BOX 368 MAIERIU OF JACa35EN UMWACIMG m W- stKH YAwjw ARE PROVIDED TO THE SAFETY HARBOR. FLORIDA 34695 RECPgXf rat SPE= ROM AID mW BE DRAWING NUMBER PHONE (813) 726-1138 IQPT CailoOR k me sEaCr nu OTHM AD—FA-0025 8 ADDENDUM MULTI -WIDE ROOF SEALING/CLOSE-UP MIP S (SEI V 'i 1 1% 1 1 1\ V V I 11 \ V v l.._ , ., V,. , RECOMMENDED OVER EDGES - LOW SIDE NOTES: 1. 30 GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS REMOVED FROM ROOF IN ORIGINAL CONDITION (EXCEPT FOR STAPLE HOLES). 6" STRIP ROOFING CEMENT REQUIRED OVER EDGES - HIGH SIDE 15# FELT UNDERLAYMENT MULTI -WIDE ROOF LINE IEAD OF ROOFING CEMENT BEADS REQ'D HIGH SIDE BEAD RECOMMENDED ON HE LOW SIDE) DAPIA APPROVAL 'ROVED BY JW TP1 5 1995 LNG. NOUKAMH UT: . UAIL: rtLr. Lcucnc JACOBSEN HOMES THESE sPEa1u110NSAND ANo oRArwcs ARE C.L.Y. 6-5-95 ORIGINAL, PROPMETARY, AND OOMIOEHML DRAMNG TITLE UATERIALS OF JACOBSEN UANIFACIU7PEG M1W ROOF SEALING P.O. BOX 368 INC. SUCH MATERIALS ARE PROVIDED TO YK SAFETY HARBOR, FLORIDA 34695 RECPEHT FOR SKC1C SMOSS 40 MAT BE DRAPENG NUMBER PHONE (813) 726-1138 INVT COWIDEHTK NO SECREI ERCH OTHERS AD-FA-0026 9 SHIPPED LOOSE HEARTH EXTENSIONS HEARTH. TNSTATU.ATTON- 1. REMOVE ANY CARPET AND/OR PAD FROM UNDER THE HEARTH EXTENSION AREA 2. INSPECT THE METAL FLASHING IN THE HEARTH AREA 10 INSURE THAT IT HAS BEEN INST40 (THIS FLASHING MUST BE PLACED ON THE FLOOR TO PROTECT THE AREA BETWEEN THE FIREPLACE AND THE HEARTH. 3. LOCATE THE HEARTH EXTENSION (SHIPPED LOOSE IN THE HOME) AND INSTALL FOLLOWING THESE STEPS - A. CARMI LY PLACE THE HEARTH EXTENSION BT THE PROPER LOCATION IN FRONT OF THE FIREPLACE ASSEMBLY. B. SECURE THE HEARTH EXTENSION TO THE FLOOR W/ 4 18 1 2' WOOD SCREWS C. FILL THE AREA BETWEEN THE FACE OF THE FIREPLACE AND THE HEARTH EXTENSION WITH A NON-COMBUSTABLE CAUUONG OR MORTAR. D. OR FOLLOW THE HEARTH MANUFACTURERS INSTRUCTIONS FOR INSTALLATION. TILE SURROUND TYP. HEARTH (MAY BE SHIPPED LOOSE) NOTES: 1. A TYPICAL TILE FRONT FIREPLACE IS SHOWN, HOWEVER THIS DETAIL APPLIES TO ALL FACTORY INSTALLED FIREPLACES. (STONE, WOOD, GYPSUM, TILE, STUCCO, ETC... MAY BE USED IN LIEU OF THE TYPE OF FIREPLACE SURROUND SHOWN ABOVE.) TYPICAL WALL WOOD TRIM FACTORY INSTALLED FLASHING APPROVED BY JUN28rZ ON flINC no(PAM WAMoomm MOW" SqM SV Mq JACOBSEN HOMES THESE SPECIi1CANOTLCE DRAWN BY:. DATE 6-16-95 REV. LiTTEf� noNS AND DRANIN(S ARE C.L.Y. S OMONAL, PROPWETARY, AND CONFIDENTIAL DRAWING TITLE P.O. BOX 368 � NAB° NNE T T� SHIP -LOOSE HEARTH PHONE (813) 72SAFETY HARBOR. 6 1138 695 � CW NO SEOV � UOIHM DRAWNG NU48FR AD-FP-0001 10 SMOKE ALARM ADDENDUM Enclosed in the home owner's packet is the smoke alarm user's manual, (if it is not there, contact Jacobsen Homes and one will be sent to you. NOTICE TO DEALER AND SET-UP PERSONNEL This home is equipped with a smoke alarm system and must be tested in accordance with the smoke alarm user's manual after the home is completely set-up and all the electrical connections are done. NOTICE TO CUSTOMER Smoke Alarms have been installed in your Jacobsen Homes. You should be familiar with the locations and operation, and learn how the alarms can be silenced once they have sounded and be familiar with its use. This is a very important safety device installed for your protection. Be sure that it is kept in A-1 working condition by testing if frequently in accordance with the manufacturer's instructions. The alarms operate on household current, and have battery backups. Its purpose is to provide early warning in case of a fire. Again we stress the importance of keeping your smoke alarms in proper working order. TESTING SMOKE ALARM Test smoke alarms after home has been set-up completely. To test the smoke alarm, press and hold the test button on the cover of the unit, until the alarm sounds. All smoke alarms should sound alarms. If all units do not alarm, replace units immediately. This test should be given to all smoke alarms individually. APPROVED BY QED INC.IfB�IR 2 5 20 q FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFELY STANDAHUS SET-UP MANUAL ADDENDUM AD-FS-0001-A 11 TRUSS SHEATHING APPROVED BY NIP INC. FEDERAL MANUFACTURED HOME CONSiRUCTIDNANDSAEETY STANDARDS DEALER (SET-UP)INSTALLED PLYWOOD FOR SHEATHED TRUSSES HINGED TRUSS - NOTE: HOLES TO BE CUT IN SHEATHING TO ALLOW OUTLOOKERS TO PASS THROUGH. TYP. OUTLOOKERS FACTORY INSTALLED PLYWOOD FOR SHEATHED TRUSSES L SIDEWALL - MARRIAGE WALL 3/8• MIN. APA OR TECO RATED SHEATHING APPLIED TO ROOF TRUSSES LOCATED DIRECTLY ABOVE SHEARWALLS (APPLICABLE TO ALL SHEARWALLS) \ \ \ \\ \ \\ \\ \ \ PENETRATIONS OF THE SHEATHING ON THE TRUSS(ES) FOR THE OVERHANG OUTLOOKER5 (PURUNS), ATTIC VENTALATION. 3/8' SHEATHING TO BE INSTALLED ON —SITE OPENINGS IN TRU55 SHEATHING MAY BE LOCATED AT ANY LOCATION ALONG THE LENGTH OF THE TRUSS. WINDZONE III (18• X 14 1/2" MAXIMUM SINGLE OPENING SIZE IN TRUSS SHEATHING) (I10 MPH) ALL EXPOSURES NOTES: ENGINEER APPROVAL: DAPIA APPROVAL• 1. 3/8• MIN. RATED SHEATHING FASTENED TO ROOF TRUSS MATH 7/16• X (NO ICLUE•REOUIRED) PANEL EDGES AND 3• D.C. APPROVED BY AT ALL FRAMING MEMBERS. MAT t 4kas .EIN PINC. FEDERAL MANUFACTURED HOME CONSTWIONANDSAFETYSTANDARDS JACOBSEN HOMES THESE SPECIFICATVO ANDCE: AND DRAWINGS ARE DRAWN BY: R.R. DATE 4-27-98 REV. LETTER-.TIONSS ll m■O MIPROPRIETARY, MID CONFIOENRAL DRAWING nnE P.O. BOX 368 MATERATERIAA LS OF JAC�SEN MANUFACTURING INC. SICK MATERIALS ARE PROVIDED TO THE TRUSS SHEATHING SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-113B RECIPIENT FOR TF.CRTC PIJRPD%s AND WST BE REPT CONIIDEIIUAL AND srm. IrRou oIHERs. DRAWING NUMBER: AD—HR-0001 12 HINGED ROOF DETAIL dSTMM OF MR M RAGE W FROM mm P0911Q1 m W-IP P09u IS APPROX 22 I)f. un HIM ROOF mm SYSIE lay Tm BECJIA A REAM NG UK m t2 FEET APART. WE ll W PW3 WM X W W W ROOF S1:M W A= WW WM 2RFUTAMaNIKRYM HINGED ROOF IN SHIPPING POSITION HINGED ROOF IN SET-UP POSITION NDSOI NOTES: 1. WAM RAND ROOF SECIRN N THE RAM POSW Ea<FOtiE S19KW WWI IMG Pom mm P0411o11 HNGED IN s P061 TO RIDGE MAK 6SFF(!=WPOST 1OPRAL .11OX W=Wff0R3- jaxr Cm REF. CALC. PG. C-RF- 223.0 - 223.6 ENL111EER APPROVAL .Sohn C. Doeden, P.k. ►C2 Enonq, Inc APPROVED BY r PINC. Revised Jun 06,2006 FFDFRAI hIA" CONSTRUCTION AND SAFETY STANDARDS JACOBSEN HOMES nm �TW NO 1 ANN0 „� emu. N O"RAor. An C09EM Al BY: O.A. DAIS 06-02-06 R£V EEi1FR J� OR IM IIM Ra BOX 3N HA S01 OF �C°1" YA"JFACRMC HINGED ROOF DETAIL /-1 QAWf7l3 SAFETY HARBOR. FLOIWA 34693 W. YATUM ARE PR0I�EED 10 AE r1 l F 9'&7iC PRIM AD MW K. DRAIM I6AIBFR PHONE (813) 726-1138 WT caamruL me 4DFIfm onus AD—HR-0002 13 HINGED ROOF DETAIL UNOERIAYMENT TO BE GLUED 3' MIN. ON BOTH SECTIONS OF HINGE ROOF. FOR WIND ZONES 2 AND 3. RAISE EXTENDED SHINGLE AND UNDERLAIIMENT AND AND A MIN. 4 1/2' WIDTH OF ROOFWG CEMENT TO TOP OF LAST SHINGLE ROW ON FIXED ROOF SECTION. (THIS IS TO BE DONE BEFORE RAISING HINGED ROOF SECTION.) SHINGLE AND UNDERLAYMENT CEMENTING AT HINGED AREA ATTACH 2 X 6 X 8' BLOCK BEFYNO 2 X 6 - OVERHANG FASCIA BOARDS AND SECURE WITH 3-/B X 3' WOOD SCREWS EACH SIDE OF GAP. APPROVED BY INRevised Nov 30,2006 INC. FEDERAL UMUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS BLOCK ATTACHMENT AT FRONT AND REAR OVERHANGS WINDZONE IA (110 MPH) ALL EXPOSURES NOTES: I. BRACE RAISED ROOF SECIM N THE RAISED POSITKN BEFORE SM ONG HNGED KING POSTS NTO POSITION. John C. DoedW Rig K2 Eng+• U113- JACOBSEN HOMES NOTICE: raw. SPEOFumm,,o omu= #A DRAM% BY. D.T. DATE 10-02-06 REV. LFTIEIC rliffn Box US C+OMM. P+�T� Aw aMMAL YAIENALS OF J IMMER UUWXNMI6 DRAMNO n7W . HINGED ROOF DETAIL ram-roP.O. SAFETY HARBOR. FLOROA 34693 PHONE (613) 726-1135 FUR � n� raT'K Rm odDwm #A S�Cil[I fra wo ORATING ruueER AD—HR-0003 14 SHINGLE AND UNDERLAYMENT APPLICATION ON HINGED SECTION INSTALL ON SITE 15# FELT WITH A 6' MIN. OVERLAP ONTO MAIN ROOF CEMENTED WITH ROOF TAR AND SECURED PER NOTE #2 CONTINUE 15# FELT TO ROOF PEAK -� ONE-PIECE SHINGLE UNDERLAYMENT 2' MIN. OVERLAP (iYP.) - o i ', rl � I 1 I r I r I fl w J I 1 I 1 7 1 6' MIN. TAR AS SHOWN 1I I I ,1r1I� r —1 SEE ........ (APPLIED ON SITE) -s8 : NOTE #3;:::: :::. . ....... rE .. . 3MIN. SEE DETAIL A r= i I i I i I i I i l i I w `o CD 1 1 I 11 1 1 1 I I I f 11 1 xW SECURE FIRST ROW OF SHINGLE TO BE INSTALLED ON ' SITE WITH • 6 STAPLES (1' X 3/4' X 16 GA OR ROOFING NAILS) PER SHINGLE MANUFACTURER'S INSTRUCTIONS AND CONTINUE TO PEAK. REMOVE THE ONE PIECE SHINGLE UNDERLAYMENT IN THE GAP (HINGE SECTION IN DOWN POSITION) BEFORE UFTING THE HINGED SECTION OF THE ROOF TO ITS FINAL POSITION AND BEFORE INSTALLING THE 15# FELT AND SHINGLES. DETAIL A VANDZONE III (110 MPH) ALL EXPOSURES NOTES: - - - - - 1. CEMENTING OF 15# FELT 1S NOT REQUIRED IN ANY AREA EXCEPT WHERE NOTED. Z FASTENING OF 15# FELT IS NOT REQUIRED. (FASTENERS APPLIED JUST TO HOLD FELT IN PLACE UNTIL A PROVED BY SHINGLES ARE INSTALLED.) 3. EXTEND THE FIRST LAYER OF ON SITE 15f FELT ONTO THE FIXED ROOF A MIN. OF 6' AND UNDER THE UST COURSE OF FACTORY INSTALLED SHINGLES IF NEEDED 70 MAINTAIN THE 6' MIN. OVERLAP ONTO THE FIXED ROOF. 4. INCLUDED IN THE HINGED ROOF ADDENDUM ARE DETAILS AD—HR-00DI (WITH SPECIFIC END PANEL LAYOUT), { I `r C. AD—HR—ODOZ AD—HR-0003, AND AD—HR-0004. FEDE AL 61ANUFACTURED HOh1E CONc TRUCTION AND SAFETY STANDARUS JACO BSEN HOMES NOZ ICR DRAAW' BY: DATE REV. LErMt DOE SPEGFlL MIN AND DRAW= ARE M.T. 9-20-03 ■ OR WIWL PRCPWARY. AND CONFDFN11AL DRAWING TITLE: SHINGLE AND UNDERLAYMENT MATETtlALS OF JAOOBSBJTI MANUFACTURING P.O. BOX 368 W. S,CII MATErM ARE FRONDED TO THE APPUCATION ON HINGED SECTION SAFETY HARBOR. FLORIDA 34696 REWW FOR SWE PUlrW AND MUST BE DRAWING NUMBER PH INE (813) 726-1138 RVT aor WDFI1K w smwr FROM Onm AD-HR-0005 15 PEAK INSTALLATION DETAILS SECURE ROOF PEAK ASSEMBLIES TO - HINGED RAFTER WITH #8 X 4" SCREWS, 6.1/2" O.C. MAX. DECKING ON RIDGE BLOCK ASSEMBLIES FASTENED WITH (6) 7/16" X 1 1/2" X 16 GA. STAPLES INTO EACH 16" O.C. RAFTER 'AND 3 1 /2" O.C. MAX. INTO 2 X 4 RAIL (TYPICAL BOTH SIDES) NDSO1 NOTES: I. SEE AD-HR-0007 FOR INSTALLATION OF UNDERLAYMENT AND SWNIM. SEE AD-HR-0002 FOR ASSEMBLY DETAILS. ALL VANDZONES ALL EXPOSURES 20 PSF ROOF 10 PSF D.L CRC - 167.01 - 167.02 3WER APPROVAL' DAPIA APPROVAL — APPROVED BY Revised gun 09,2006 .4 04 John 0. Dosijwi, F.f=. FEDERAL MfW11Fa(TU ONAIDN C. coRsmucno" Ano sAFEn srAADAaos .92 EAring, Irlc JACOBSEN HOMES None ,Htsc sPEaTleAno"s AND URANNCS AK UT: O.A. 06-06-06 IL•• I I Ili MONAL. PROPKIART. PAD COWEE TAL °Amms or Acam MmrAC7UR ` DRAWING ARE: ,I P.o. Box 366 NG SM YAn3W AK PRDTOED 10 TIC PEAK INSTALLATION DETAILS SAFETY HARBOR., FLORIDA 34695 REMM rot SPECEtC KRNM AND MUST K DRAWING MLIU R: PHONE (727) 726-1138 PVT ovtroam AN slotR "m MCI% AD-HR-0006 16 SHINGLEZUNDERLAYMENT INSTALLATION SITE INSTALLED SHINGLES (USING THE 6 FASTENER METHOD) AND CAP INSTALLED PER MANUFACTURERS INSTALLATION j INSTRUCTIONS. INSTALL FIRST LAYER OF 151 FELT TO ROOF WITH A 6' MIN. WIDTH OF ROOF CEMENT AT EACH END TO ROOF DECK AND/OR EMSTING FELT AS SHOWN. TOP COURSE(S) OF SHINGLES TO OVERLAP PEAK AS SHOWN. SHINGLE INSTALLATION SEE OTHER DETAILS FOR 91 INSTALLED ROOF PEAK INSTALL TOP LAYER OF 151 FELT TO ROOF IMTN A 6' MIN. WIDTH OF ROOF CEMENT AT EACH END TO ROOF DECK AND/OR EXSTING FELT AS SHOWN. UNDERLAYMENT INSTALLATION NOTES: DAPIA APPROVAL• AP ROVED BY AUG 0 1 2004 INC. FEDERII MANUFACTURED HOME - _ NOTICE DRAWN BY: DATE: REV. LETTER: JACOBSEN HOMES TNEsE sKacATXINS me onwi s ARE M.T. 7-2$-04 MMAL. PRWKTARY. AND COWMIIAL DRAWING TITLE: _ „ P.O. BOX 368 MATERIALS Of JACWSEN MANVACTINONG SHINGLE/UNDERLAYMENT INSTALLATION NC 9" MATERIALS ARE PRNM TO TfE SAFETY HARBOR. FLORIDA26-18,695 KOPEK NO ICA5ESET �w5 oRAWAIG NUMBER: OTHM AD-HR-OW7 l ADDENDUM TYP. SHIP -LOOSE PLUMBING SUPPORT �- FASTEN 10 FLOOR FRAMING MEMBER W/ STAPLE OR NAG. BANDING STRAP VWPED' AROUND PIPE AND FASTENED TO FLOOR FRAMING. WE OF NOT LESS THAN 1/4' PER FOOT MUST BE MAINTAINED TOWARD THE OUTLET. * RE 1HIS GRADE CAN NOT BE ACHIEVED, NOT LESS THAN 1/8' 'OOT MAY BE USED WHEN A FULL SZE CLEANOUT IS INSTALLED AT THE UPPER END. I— VIEW OF MAWPIPWG NOTES: 1. PIPE CLEANER AND CLUE SHALL ALSO BE SUPPLIED BY THE MANUFACTURER FOR PLUMBING CONNECTIONS. 2. 48" O.C. MAX. SUPPORT SPACING. M AWROVAL' INFP� s• •,11� A: INC. JACOBSEN HOMES iwsE SKCM q+S MO DRAWNCS M �iA1� 8T. R.R. "' 7--17-97 Rcv. LETTER. I CAMAL PRMTARY. AHD CGr81DFF1— DRAIMG TITLE- P.O. 8Ox 368 MAMMALS OF 4%03M M&NI AMING 70 ?It PLUMBING SUPPORT „ SAFETY HARBOR, FLORIDA 34695 a w+ CM " RE FMCD � "M BE �_H_PHONE (813) 726-1138 ,En CONMU fUl NO IOU MV Gnu DRANHG NW3ER: AD-PL-DDOt 18 ON SITE PITCHED ROOF DETAILS IMPORTANT NOTICE THE ON SITE PITCHED ROOF INSTALLATION (INCLUDING SHINGLES AND CAP) MUST BE COMPLETED WITHIN 60 DAYS OF DELIVERY TO THE HOME SITE. FOR ATTACHMENT OF ALL VENTING (INCLUDES 12 EXHAUST k ROOF), SOLAR TUBES AND PLUMBING 4 1 VENTS SEE AD—PR-7007 do 7009. MAX. ROOF SLOPE FOR ROOF DECKING DETAILS SEE AD—PR-7004. FOR ATTACHMENT OF PITCHED RAFTER TO TRIPLE WIDE SEE FOR ROOFING DETAILS SEE AD—PR-7002 j� SEE AD—PR-7008 SHIP THIS SEC. LOOSE j 1 — � — — -(SITE INSTALLED) — — — FOR OVERHANGS NCLOSEDT-T T S EE E-ET ASL r REMOVE ALL FACTORY INSTALLED POLYVINYL BEFORE INSTALLING THI �TIS yy ON SITE PITCHED ROOF RAFTERS I I ,;L1v ItR SECTION OF TRIPLE WIDE ��✓-o�-o",f v P TYPICAL TRIPLE WIDE HOME WITH SITE INSTALLED PITCHED CENTER SECTION RAFTERS MNDZONE III . ALL EXPOSURES (110 MPH) 20 PSF ROOF 10 PSF D.L. NOTES: DAPIA APPROVAL: AFIPROVED BY JUN IP INC. qFMALUFACTURED HOME NANDSAFEIYSTANDARDS J AC 0 BS E N HOMES THESE sP>:cIFICANOTICE 1IDNs AM atAMLNGS ARE DRAWN BY: M.T. DAIS: f —04-04 REV. if TIER: ORIMAL, PRWRETARY. AND CON WTIAL MATERIALSOF JA008SEN MANUFACTURINGS DRAWING TITLE. ON SITE PITCHED RQOf DETAILS A P.O. BOX 368 uG HOT MATERIALS ARE PROV= TO THE SAFETY HARBOR. FL40RIDA 34,695 NEOPENR FOR SPEONO ROWS ARID MUST K DRAWING NUMBER: PHONE (727) 726-1138 IEPT CdIWRAL NO SEYAET 110I GTHIM AD—PR-7001 19 ROOF- TO ROOF ATTACHMENT SECURE STE SITE INSTALLED 7/16- MIN. ROOF WITH 7/16- I1S1%2X 16 GA. ROOF DECKINGSTAPLES DECKING SECURED WITH 7/16' X 1 1/2- (12) EACH SIDE OF MARRIAGE LINE TO X 16 GA. STAPLES. 2' O.C. MAX. TO EACH 16' O.C. RAFTER. EACH 16' O.C. RAFTER. SEE DETAIL 'A' SEE NOTE jn 11' MIN. SITE INSTALLED DECKING OVERLAP SITE INSTALLED RAFTER TO FACTORY INSTALLED ROOF DECKING ALIGN WITH FACTORY INSTALLED RAFTER BELOW. SEE NOTE 12 18' MIN. BE RIDGE BEAMS EE NOTE /4) h I DECKING YYU CROSS-SECTION REF. PG. RC-07-0044 FACTORY INSTALLED RAFTER (CENTER SECTION) WINDZONE' q ALL EXPOSURES (110 MPH) 20 PSF ROOF 10 PSF D.L. NDS01 -' C-FS3 - 88.01 NOTES: DKRM APPROVAL DAM APPROVAL: 1. SECURE EACH 16' O.C. RAFTER TO RAIL BELOW WITH 2-110 X 4 1/2' SCREWS AT EACH RAFTER END. SITE APPROVED BY INSTALLED PITCHED RAFTER TO ALIGN W17H FACTORY INSTALLED 04 RAFTER. (EA. SCREW TO HAVE 1 1/4' PENEIRA71ON YIN.) 17p, Jun 09,2006 2. ATTACH MATE LINE RAFTER RAILS (OR RIDGE BEAMS) WITH / j10 X 4 1/2' SCREWS 9- QC. MAX SPACING b 09 I SEE AD-FA-0020 FOR GAP TREATMENT BETYIEEN SECTIONS. John C. oe-own, f! b:. FEDERAL MANUFACTURED HOME K2 Engkmr". Inr. CONSTROCFIDN AND SAFETY STANDARDS JACOBSEN HOMES ■ NOTICE: T1ESE=�RDNsAmcRAmrsAK e4w+L ►"RTIA". AM CMUMINn.& DRAYN BY: o.A DAIS: 06-02-05 REV lET1ETC DRAWING nnL: �� P.O. eox 366 wYE M$ OF .M MMM MANWACTUMS6 W. MXH uA70M AK PRo►oEo 1D ROOF TO ROOF ATTACHMENT SAFETY HARBOR. FLORIDA 34695 REOW 91 NEW yip VJR !E DRAWING NUMOM PHONE (727) 726-1138 mF caflo n Mo mmf FROM ns ow AD-PR-7002 20 RAFTER TOP END ZONE RAFTERZOVERHANG ASSEMBLY ALT. CONSTR. RAFTERS 2 X 6 OUTLOOKER 26' O.C. MAX. BETWEEN OUROOKERS �_ ��:_ « o� 2 X 6 OVERHANG FASCIA THIS TRUSS INSTALLED ON SITE BOTTOM CHORD 160' DOUBLED END ZONE RAFTERS TYP. 16' O.C. 2 X 6 FASCIA FASTENED TO OUXOOKER W/MIN. 9- 7/16- X 2 1/2' X 16 GA. STAPLES OR MIN. 6- .131' X 3' NAILS (TYPICAL AT ALL CENTER BRACES) MAXWn To K maw; 16' TYP. 16' 2 X 6 OUTLOOKER 26' O.G MAIL BETWEEN OUTLOOKERS ALL OUTLOOKERS SHOWN ARE 2 x 6 SPF 13 FLAT —2 X 4 NAILING BLOCK (INSTALLED ON SIZE) MIN. 3- .131' X 3' NAILS FROM NAILING BLOCK INTO RIM PLATE OF ADJACENT SECTION OF UNIT, AND MIN. 2- .131' X 3' NAILS FASTENING FASCIA INTO END OF NAILING -BLOCK SEE CHART FOR FASTENING . OUTLOOKER TO TOP CHORD MULTIPLE TRUSSES FASTENED TOGETHER W/IfIN 131' X Jr NAILS OR MIN. 7/16- X 2 1/2 X 15 GA STAPLES 16' O.Q MAXIMUM INTO TOP & BOTTOM CHORDS ONLY. \— 2 X 6 OVERHANG FASCIA END ZONE ASSEMBLY - NOTE: (SHIPPED ASSEMBLED FOR SITE INSTALLATION) OUTLOOKERS TO BE SECURED TO EACH TRUSS OF THE DOW 1RUSSfS LOCATED N THE ETDZONE PER FASTEM CHART: SINGLE TRUSS ONLY REO'O OUTSIDE OF 3 FT. AREA EXM TRUSS WIT BE PLACED ON EITHER SIDE NOTES: 1. ALL TRUSSES LOCATED WITHIN 36" OF THE END OF THE SECTION TO BE DOUBLED. 2. SEE OTHER DETAILS FOR TYPICAL ROOF FRAMING. ` 3. EACH TRUSS IN END ZONE AREAS ARE REQUIRED TO BE FASTENED PER AD-PR-7002 TYP. OUTLOOKER FASTENING: FASTENERS: aimm. PETETRATM .131 PD NAIL 3 1 1/r 15 GAL STAPLE 5 1' 110 SCREW 1 I 1' (" L 1P) OUTLOQOIt FAS1EfM MAY BE IMAM VANDZONE 111 FROM TOP CHORD DO M F PDMIM ALL EXPOSURES 5 MANTAO®. (110 MPH) 20 PSF ROOF 10 PSF D.L. REF. CALCS. C(L(_ - lyb. o ENGINEER APPROVAL I DPM APPROVAL• A PROVED BY JUN �. noes, jft INC. En - 'RdLMANUFACTURED HOME �"�Tk.erjY1g, jm CO STRUCTION AND SAFETY STANDARDS DRAWN BY DATE REV. lET1ER JACOBSEN HOMES TEE MANE Is AK R.R. 1-30-04 01MIN, PRO-MOr, NO OMMM DRAWING MAL _ m m P.O. BOX 368 WASOF �MGME MAPROYMA END ZONE RAFTER OVERHANG ASSEMBLY INc seal Y11WD�5 ME OED 10 iFE SAFETY HARBOR, FLORIDA 34695 faMl F0t 90C PU6'OIf3 MID MAT IE DRAWIG NUMBER PHONE (727) 726-1138 w1 CQr1tr<1rm w mm nw omm AD-PR-7003 21 ON SITE PITCHED ROOF DECKING INSTALLATION 16" MIN. r TYP. ROOF FRAMING DECKING / 16" ON CENTER OFFSET A If C TRIPLE WIDE CENTER SECTION PEAK\ - SITE INSTALLED DECKING ON PITCHED TRUSS SECTION It REMAINDER OF NO BLOCKING REQUIRED BOTH OUTSIDE SECTIONS (1 FAT CONTINUOUS PANEL � ROWS OF SHEATHING) SEAMS BETWEEN TRUSSES SEE OTHER DETAILS TO SECURE TRIPLE WIDE MARRIAGE LINE SITE INSTALLED PITCHED TRUSSES .�.. octosv 'CAI' REVISED D� � APA RATED ROOF DECKING (OR EQUAL) e k 9 WINDZONE III ALL EXPOSURES (110 MPH) 20 PSF ROOF 10 PSF D.L. NOTES: . DAM APPROVAL- 1. 1/4-. MAXIMUM GAP AND 1/16" MINIMUM GAP BETWEEN DECKING AlPROVED BY PERPENDICULAR AND PARALLEL TO TRUSSES. 2. ROOF DECKING MATERIAL TO BE 7/16" APA RATED ROOF (24/0 SPAN RATED) DECKING (EQUAL OR BETTER). JUN to 3. OTHER TRIPLE WIDE SECTION (NOT SHOWN) WILL BE THE INC.SAME DECKING PATTERN. N FED AL MA7AND D HOME CON TRUCTITYSTANDARDS NOTICE: DRAWN BY. DATE:REV. LETTER. JACOBSEN HOMES >� SPEOr1CATION5 AM DRAMICS ARE R.R. -04 ORIGNAl. �r TART. AM �U"� DRAWING TITLE: P.O. BOX -w MAMMALS 0 NA JACOBSEN FAC1<IRNG r INC. Soa MAMMAS ARE FROMM 10 WE � �TCFIED ROOF DEgCING INST. SAFETY HARBOR. FLORIDA 34695 IEEONOirI FOR scan6I NEt Rorm Ab n PHONE (727) 726-1138 IVI Cowso"m Are Starr rRm owm AD—PR-7004 22 NOTES: SITE INSTALLED PITCHED ROOF, VENTING TYP. 50 SO. IN. ROOF VENTS (SEE AD-PR-7006 FOR QUANTITIES) TYP. 100 SO. IN. CUTOUTS FOR - VENTILATION OF ROOF SECTION (SEE AD-PR-7006 FOR QUANTITIES) FIAT CENTER SECTION OF ROOF INSTALLED AT MANUFACTURER TYP. ROOF INSULATION J / CEILING PANEL fr..-cvoL EE s AW V � MARRIAGE WALLS ' F �fA-l' CENTER SECTION SITE INSTALLED CENTER SECTION OF ROOF 1MNDZONE IR ALL EXPOSURES (110 MPH) 20 PSF ROOF 10 PSF D.L. DAM APPROVAL: PROVED BY au�20 IHINC. MANUFACTURED HOME mION AND SAFETY STANDARDS NOTICE DRAWN BY: I DAIS: REV. LETIM JACOBSEN HOMES 7MMsvET>MT06"MA.+aAE R.R. 01-22-04 ael UL PRWKTA". AM O11iMUft DRAWNC TIME _ P.O. BOX 368 MAMIMS Or JACO l MAKFACTLOW SITE INSTALLED PITCHED ROOF VENTS W— WW MM114S ARE PRMV To TIE SAFETY HARBOR. FLORIDA 34695 KMW fdt 9MC PWPM AID Mb1 K DRAWWIG M AXk PHONE (727) 726-1138 IEPT m m va AID smy TRw oT+m • AD -PR- 7005 23 bZ 900L-Nd-av ma0 Nu OWN ON ltlltMMOW Ld31 Ktl-9ZL UZI) 3NOHd 713mm 9mVH0 lv Lsm awv maw 31 101 uadJly 969K vaWOli 'dwsvN AI3JVS 9NIIN3A 30021 �r.nm1 tessom�eo SWRMvvm e9c xoe o d O =311u 9NwvH0 inuoaMoo ara u1vL3aaoae '1v►toalo do—zz—Lo a'a 'b" S2@MV ° °" 9101L1f7W3.6 IM S�Y�IOH H�SSO��P H" Z831131. A3H .. A8 WV'bo 3=OM souVONVIS M39VS ONV NO N00 311OH 03'dnl3v]nNvw lv 3033 ` ONI As MAoL]d b z 0 a J00H do NOI.L03S UNIN33 USMV,LSNI HIIS I I I S11V1A 39VISWA 'I LN3A A01 (SLN3n3min03a NO! LHVH3 33S) I" Mol SLN3A JOOH 'NI '0S OS 'dU %MIR sww"o (M mumv w l06 h i f .0-p9 01 J-29 IN vl 1 i .9-Z9 at .00-.* VON 1 - 91 01 - K Iron Im S-.u' 01 INA 001 -IN A WIN 71191tl1 mm3is f Cast) NOIL33S 831N33 JD WI HILN33 - I F z I Qi� -- � F= LN3A HDIH i I IC'l LN3A 401 1N3A MO1 I a S11VM 39VWHV11 I z cn I I a3'IIV.LSNI AHiO.L3V.4 J008 do N01133S HaIN23 IV'IA S11VM 39VWWR .1 1 r; .e-7 S .0-4ag 01.9-.Z9 .9-.Z9 OL AL-.9► f .O1-.* Ol S-Ar Z S-.(f OL .9-.91 L ,9-.Sl 01 0 'S310H MOM i119N31 Nm:)3s x Lo91) NOI 0 00 S310H .LN3A .Lfl0lfl3 'NI S 001: F� (sLN311MM*ld MOl 1Hv1D 33S) • 1_r MM315 XX)H !D N001106, l 1103 SLrolro 'N 'OS 001 'dU S11VIL 39VINSYN i z 0 OMI NRA A00H PITCHED ROOF EXTENDED VENTS SITE INSTALLED VENT CAP OR SOLAR TUBE SITE INSTALLED FLEX DUCT/ SITE INSTALLED VENT CAP (SEE DETAIL 'A') SITE INSTALLED CENTER ,SECTION OF ROOF EXTEND FLEX DUCT 3' ABOVE RAFTER SHEATHING FLEX DUCT (FACTORY INSTALLED) FACTORY INSTALLED SHEATHING FACTORY INSTALLED CENTER SECTION OF ROOF TYP. CONNECTION TO VENT FAN, SOLAR TUBE, OR EXTEND TO RANGE HOOD MARRIAGE WALLS EXTEND PIPE 3' ABOVE SHEATHING PLUMBING VENT (FACTORY INSTALLED) CEILING PANEL MARRIAGE WALLS SITE INSTALLED PLUMBING VENT PIPE (EXTEND 3' ABOVE ROOF) (SEE DETAIL 'B') FACTORY INSTALLED FLAT CENTER SECTION VENT CAP (OR SOLAR CAP) EXHAUST DUCT SPLIT AND FASTENED TO ROOF DECKING OR BACKER WITH MIN. 4- 8D NAILS IN LIEU OF FASTENING DUCT TO VENT CAP. SITE INSTALLED FLEX DUCT \-SHEET METAL SCREW FLEX DUCT (FACTORY INSTALLED) NOTE: EXHAUST DUCT (FLEX DUCT OR RIGID) SECURED WITH I SHEET METAL SCREW MINIMUM AND ALUMINUM TAPE TO SEAL AROUND DUCT AFTER SCREW IS IN PLACE. DETAIL 'A' NOTES: 1. FOR VENTS NOT SHOWN INSTALL PER MANUFACTURERS SPECIFICATIONS. 2. SEE OTHER DETAILS FOR ROOF FLASHING INSTALLATION. 3. EXHAUST DUCT MAY BE RUN THROUGH EITHER A SOUARE OR ROUND HOLE CUT IN ROOF DECKING. 4. RANGE AND BATH/AIR DUALITY FLEX DUCTS TO BE SPLICED WITH ALUMINUM TAPE AS SHOWN IN THE DETAIL ABOVE. 5. SECURE SITE INSTALLED PLUMBING VENT PIPE IN70 COUPLER WITH APPROVED CLUE. PLUMBING VENT ROOF FLASHING (SITE INSTALLED) VENT PIPE ITE INSTALLED) r(S-"s- ) COUPLER p (SITE INSTALLED) VENT PIPE D-,e(FACTORY INSTALLED) DETAIL 'B' DAPIA AP40VED BY . JU14 INC. RFEDERALNUFACTURED HDIVIE ON AND SAFETY STANDARDS NOTICE DRAWN BY: DATE REV. LETTER: JACOBSEN HOMES THESE SKOFIrAWNS " MAMIGS AK R.R. I 01-23-04 ORKPIAL wlDva[101 AND CD MnAL DRAWING BILE: _ P.O. BOX 368 Nt 9" AT jKC0FUS AK aAHIIr 10 THE PITCHED ROOF EXTENDED VENTS Nc 9X]I rI►malts ARE PRovoE� ro THE SAFETY HARBOR. FLORIDA 34695 REM NI MR 9 E0:1C NTiPM NO NMI K DRAWING MJ ak PHONE (727) 726-1138 KEPT COWMIMI AND 5=1 FROM OTHERS AD-PR-7007 25 SITE INSTALLED SHINGLE AND UNDERLAYMENT FIELD INSTALLED 151 FELT WIN. INSTALLED OVER THE FACTORY INSTALLED UNDERLAYMENT WITH A 6' MIN. OVERLAP AND A MIN. 6'. WIDTH OF ROOF CEMENT. 151 FELT 70 HAVE A 6' MIN. OVERLAP 15/ FELT ALSO CEMENTED WITH A 6' WIDTH AROUND AND A MIN. 6' WIDTH OF ROOF CEMENT ALL PENETRATIONS OF THE UNDERLAYMENT AND THIS ALSO APPLES TO ENDLAP SEAMS. PERIMETER OF ROOF. I l - r 1 r 1-r-1 r -1 ' 1 1 FIELD INSTALLED ROOF 9 0THNG (TV.) � I 6" WIDTH OF ROOF CEMENT WHEN A OPTIONAL 151 FELT IS INSTALLED. I r -1 r1 r1 '1 OPTIONAL LATER OF 151 FELT 0 r-1 N � � >_ lD CLO L WJOF SHEATHING (TYP.) ur SHINGLES TO BE FIELD INSTALLED AFTER 1HE UNDERLAYMENT HAS BEEN INSTALLED. L THE LAST COURSE OF FACTORY INSTALLED SHINGLES TO LEAVE A MINIMUM OF 6' FROM THE TOP OF THE SHINGLE TO THE EDGE OF THE FACTORY INSTALLED DECKING FOR UNDERLAYMENT OVER LAP OF 6' MINIMUM. 1/2' 1/2" TO 1/2' 3' 3' 1/2' 70 TO 1 1/2' A. m 1 1/2 FASTENING DETAIL NOTES: 1. CEMENTING OF OPTIONAL 151 FELT IS NOT REQUIRED IN ANY AREA EXCEPT WHERE NOTED. 2. FASTENING OF OPTIONAL 151 FELT IS NOT REQUIRED. (FASTENERS APPLIED ARE JUST TO HOLD FELT IN PLACE UNTIL SHINGLES ARE INSTALLED.) 3. SHINGLES INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS ONLY WHEN SPECIFIC APPLICATIONS ARE NOT COVERED. WINDZONE DI (110 MPH) ALL EXPOSURES AP ROVED BY �UN� a �04 ING. i FEIDE L MANUFACTURED HOME CONST UCT ION AND SAFELY STANDARDS JACOBSEN HOMES NOTICE DRAWN BY: DATE REV. LETTER >� s+>EaH,Gup,6 AM 11RAw►A;S AKM.T. 02-03-04 o1OMM. PRO KIAn. AM ao EW(IM DRAWING IFI E: ® 26 P.O. BOX 368 W- SLAIs a , MS AK ROWDIDUAIQtA10 If SITE INSTALLED SHNGLE AND UNDERLAAYMENT — 11iC SIIOH 1uTEA1ALS AAE PNOVDED 10 11E SAFETY HARBOR, FLORIDA 34695 RECFW r0l 9fOFlt H1FPati<s MD WIST M DRAWW NUMBER: PHONE (813) 726-1138 IVT cammilk ao SFCKT Twos oum AD —PR— 7U08 26 ol SITE INSTALLED SHINGLE AND UNDERLAYMENT FIELD INSTALLED 150 FELT MIN. INSTALLED OVER THE FACTORY INSTALLED UNDERLAYMENT WITH A 6' MIN. OVERLAP AND A MIN. 6" WDTH OF ROOF CEMENT 151 FELT ALSO CEMENTED VATH -A 6' WOTH AROUND 151 FELT TO HAVE A 6" MIN. OVERLAP ALL PENETRATIONS OF THE UNDERLAYMENT AM I' AND A MIN. 6* WOTH OF ROOF CEMENT PERIMETER OF ROOF. CEMENT SEMIS. THIS ALSO APPLIES TO tENDLAP .. FaD INSTALLED ROOF SHEATHING (TYPI r -i 6' VADTH OF ROOF CEMENT WEN OPTIONAL 151 FELT IS INSTALLED- OPTIONAL L11YfR OF 151 FELT L Ls ONE-PIECE SHINGLE UNDERLAYMENT ROM SHEATHING (TyP-) THIS Row OF SHINGLES TO BE FIELD INSTALLED AFTER THE UNDERLAYMENT HAS BEEN INSTALLED' THE LAST COURSE OF FACTORY INSTALLED SHINGLES TO LEAVE THE TOP OF THE SHINGLE TO THE EDGE A MINIMUM OF 6' FROM INSTALLED DECKING FOR UNDERLAYMENT OVER OF THE FACTORY - LAP OF 6. MINIMUM- 1/2* TO TO 3 31 VANDZONE III FASTF�ING DETAIL (110 MIPH)' ALL EWOSURES . ENGPW APPROVAL- OAPIA APPROVAL NO APPROVED BY 1. CEMENTING OF OPTIONAL 15# FELT IS NOT REQUIRED IN ANY AREA Revised EXCEPT WERE NOTED- Oct 29,2007 2. FASTENING OF OPTIONAL 151 FELT IS NOT REQUIRED. (FASTENERS APPLIED John ..'sn', INC HOLD FELT.IN PLACE UNTIL SHINGLES ARE INSTALLED.) EDEM MANUFACrURED HOME .ARE JUST TO InG. . AFETY I ON INSTRUCTIONS K2 DOMIC0111g' NSTAljcnON AND q STANDARDS 3. SHINGLES INSTALLED PER MANUFACTURERS INSTALLATION ONLY WHEN SPECIFIC APPLICATIONS ARE NOT COVERED. DAIS RD. LETTER: NOTICR O.A. 10-24-07 JACOBSEN HOMES Iftm S-drim.71016 " G llu: 7 omcom PR&m9my. MO cmFumm SHINGLE AND U A 11"FACUM SITE INSTALLED WAManS OF J wt so MAMW mg m Tw NUMBER: P.O. BOX 368 FRIMR W W09 BE AD-PR-7008 SAFETY HAREM. FLOF40A 3495rbi onm PHONE (3113) 726-1136 LZ 600L-Nd-GV d]SMN ONMVH0 SU3f a rai IY= ae WaKUPm 1,CM 31191M OM Si90NW 31a40dS IAi 111 WWI et11-9U. (CIO) 3N0Hd 569►t V01MOli 'MOBMVH A133VS — - muv p wvn 89t x08 'O'd Ah El NOIIVIIVISNI 9NIHSVIJ 'dill 31111 9WVW 31111113 pip O111 'AWL3 "u -MOW 3bV S9ww110 Oa 9NO W3UO3E ISM r� Tit �T (� 7 �a SZW OH NSSgOo V 1 to—vo—zo fn 131131 H AVG 18 rwrao 39LLON SGUVONH1SA13JVSONVN01l3f1H SN00 34"dOH(i3uniovinmItl 13033 'ONI ':)'0 '(39NVlj 3O ON3 N3MOl H30Nn 0311ddV S319NIHS) .9 S3ldV1S A8 C13AOH d -V9 9l X _l X _l 'Nin H1UA 300S 319NIHS Ol 03N31SV3 39NV13 d008 l = S�o@ =1YA08ddY YIdYO 'NVH 3801 MVIOS A8 031lddnS 38n1 (HInVO 03AOMddV NV H1YA 03Mn33S SSV1 MNIHS HIIM M3A03 38 Avw 39NV13 w01108) S310NINS M3AO 30NTU 30 w01108 HL VA 'S3I9NIHS M30Nn 39NVli 30 d01 ONV '1N3rlAVlb30Nn 30 d01 NO '300M Ol 03Mn33S '39NVI3 H311VN Hi WI '3w00 3enl mv105 3008 310NIHS 1V31dU . NOUSTIVISNI SEMI H IOS Ido UVA 3115VW ON1 -300M HIVA V38V 39NVI3 3H1 01 MNIHS 3H1 d00M Ol ONIHSVl3 0NIN31SV3 ONIMn:M A3ONV13 1NM LOOM ANV M3A03 Ol 03nddV 38 AV" 5310NH5 IVNOLLdO MO! S3ldV1S d0 n311 NI O35n 39 AVn SIIVN wnniNin _t x _C11- W SIIVN 9N1300M wnwlNM X 9NIHSVl3 3008 _t _SOL' 3H1 9NIddVlM3A0 S310NHS TIv M30Nn 0NV SM3N31SV3 M313VM 0311V1SNI 01313 1V31dAl M3A0 0311ddV MV1 ON30CM 1 3008 310NIHS 1V31dU SM3N31SV3 11V 1V 39NV13.9NIlIVN 1130Nn MVl 9NI300M NOIZVTIVJSNI ONIHSVIA 'IdOIdU ADDENDUM GENERAL NOTES / TIE -DOWNS NOTES: 1. FRAME DE -DOWNS SHALL BE INSTALLED TO PROPERLY SECURE THE HOME. 2. VERTICAL TIE -DOWNS ARE REQUIRED IN ADDITION TO THE FRAME TIE -DOWNS. A VERTICAL TIES MAY BE SECURED TO THE SAME GROUND ANCHOR AS THE FRAME TIE -DOWNS WHEN A DOUBLE HEADED ANCHOR IS USED AND IS CAPABLE OF RESISTING THE COMB114ED LOADING. WIN ANCHORS ARE NOT INSTALLED AT THE ANGLE(S) SPECIFIED IN THE TABLE(S), A STABILIZER PLATE MUST BE ,NSTALL_E'D IN ACCORDANCE WITH THE ANCHOR MANUFACTURER'S INSTRUCTIONS. 4. FRAME IIE-DOWNS AND ANCHORS ARE NOT SUPPLIED BY JACOBSEN HOMES (TO BE SUPPLIED BY OTHERS). 5. VERTICAL BE STRAPS MAY BE SUPPLIED BY JACOBSEN HOMES OR ANCHOR BRACKET MAY BE INSTALLED BY ' JACOBSEN HOMES FOR ATTACHMENT OF VERTICAL TIE STRAPS, IN EITHER CASE ALL ANCHORS AND END TREATMENTS ARE TO BE SUPPLIED BY OTHERS. 6. ALL GROUND ANCHORS AND FRAME TIES SHALL BE INSTALLED PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. GROUND ANCHORS AND FRAME TIES ARE NOT TO EXTEND BEYOND THE EXTERIOR WALL OF THE UNIT. 7. STEEL ANCHORING EQUIPMENT EXPOSED TO THE WEATHER SHAM BE PROTECTED WITH A MIN. OF 0.30 OL OF ZINC COATING PER SQUARE FOOT OF STEEL 8. DESIGN BASED ON 95 1/2- I -BEAM SPACING AND A MAXIMUM SIDEWALL HEIGHT OF 8'-0• (82• I -BEAM SPACING IS ACCEPTABLE FOR 10' WIDE SECTIONS OF MULTI -WIDE UNITS W/ 90' SIDEWALL HEIGHT ONLY). 9. LONGITUDINAL TIES SHALL BE INSTALLED ON THE INSIDE OF EACH I -BEAM AT THE CROSS -MEMBER LOCATIONS OR PER ALTERNATE DETAILS IN ACCORDANCE WITH THE SPACING TABLES AND NOTES 4, 6, 7 AND 16. 10. FRAME TIE -DOWNS SHALL BE 'WRAPPED' AROUND THE MAIN [-BEAM (AS SHOWN ON TIP. CROSS-SECTION DETAILS) AND SHALL COME OFF THE TOP FLANGE OF THE I -BEAM WITH AN APPROVED BUCKLE OR LOOP. 11. ANCHORS SHOULD BE CERTIFIED FOR THESE CONDITIONS BY A PROFESSIONAL ENGINEER ARCHITECT OR A NAIIONALLY RECOGNIZED TESTING LABORATORY AS TO THEIR RESISTANCE BASED ON THE INSTALLED ANGLE OF THE DIAGONAL TIE AND/OR VERTICAL LOADING AND ANGLE OF ANCHOR INSTALLATION k@ TYPE OF SOIL IN WHICH THE ANCHOR IS TO BE INSTALLED. 12. GROUND ANCHORS SHOULD BE EMBEDDED BELOW THE FROST LINE AND BE AT LEAST 12' ABOVE THE WATER TABLE. 13. GROUND ANCHORS SHOULD BE INSTALLED TO THEIR FULL DEPTH, AND STABILIZER PLATES SHOULD BE INSTALLED TO PROVIDE ADDED RESISTANCE TO OVERTURNING OR SLIDING FORCES. 14. 'ANCHORING EQUIPMENT SHOULD BE BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT TO RESIST THESE SPECIFIED FORCES IN ACCORDANCE WITH TESTING PROCEDURES IN ASTM STANDARD SPECIFICATION D3593-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL AND SEALS. 15. ALL GROUND ANCHORS TO BE RATED FOR LOAD LISTED IN TABLES, TIMES 1.5 SAFETY FACTOR OR AN ULTIMATE LOAD OF 47251 (31501 DESIGN LOAD), WHICHEVER IS GREATER. VALUES IN THE TABLES ARE DESIGN LOAD VALUES. 16. A MAXIMUM OF TWO LONGITUDINAL TIE -DOWN STRAPS MAY BE INSTALLED AT A SINGLE CROSS -MEMBER LOCATION. IF MORE THAN TWO LONGITUDINAL TIE -DOWNS ARE REQUIRED (SEE APPROPRIATE SPACING TABLES) ADDITIONAL CROSS - MEMBERS MUST BE USED FOR ATTACHMENT OF STRAP(S) (OR SEE OTHER DETAILS FOR ALTERNATE STRAP ATTACHMENT). 17. LONGITUDINAL TIE -DOWN STRAP(S) MAY BE INSTALLED AT AN ANGLE NOT PERPENDICULAR TO THE CROSS -MEMBER TO WfBCH IT IS ATTACHED (SEE NOTE 16) IF REQUIRED TO MISS PIER LOCATIONS OR OTHER OBSTRUCTION(S). 18. ALL FIGURES (DETAILS) SHOWN IN THIS SECTION ARE TYPICALS ONLY. REFER TO THE APPROPRIATE TABLES FOR THE REQUIRED NUMBER, SPACING AND/OR SPECS OF SPECIFIC TIE -DOWNS AND ANCHORS REQUIRED. 19. SEE OTHER DETAILS IN THE SET-UP MANUAL AND ADDENDUM FOR BLOCKING P.EQUiREMENTS. ALL BLOCK:NG DETAILS CONTAINED WITHIN THIS MANUAL ARE APPLICABLE FOR ALL ZONES AND ALL EXPOSURES. NOTES: ENGINEER`9QQN4fj�ll D �uJ,,UAMA AFFKUVAL. )O•Q� THESE NOTES No qF cc,L ROVED BY /a,,,., TES AND DETAILS ARE APPLICABLE FOR WIND ZONE II AND/OR WIND ZONE III. THEY - ENE8703571 ,Illt4 1 5 ARE ALSO APPLICABLE TO BOTH EXPOSURE 'C' INC AND EXPOSURE V. SEE APPROPRIATE TABLES � TAr FOR SPECIFIC INFORMATION ON EACH. 6 A r�� - O.• NOTICE ��4j�TT TTIIIIi t itt� DATE: REV. LETTER: C.L.Y. 5-19-95 JACOBSEN HOMES THESE SPECIFICATIONS AND DRAWINGS ARE CRICINAI. PROPRIETARY. AND CONFIDENTIAL DRAWING TITLE: n P.O. BOX 368 UATERIALS OF JACOBSEN MANUFACTURING TD-GENERAL NOTES /A-i\ SAFETY HARBOR, FLORIDA 34695 WC. SUCH MATERIALS ARE PROW TO THE REOPENT FOR SPECFIC PL 41MU AND YUST K DRAWING NUMBER PHONE (813) 726-1138 INEPT COWIDENTLu NO SECRET FRw Dim AD-TD-0001 28 ON SITE PITCHED ROOF DECKING -INSTALLATION TYP. ROOF FRAMING 16' MIN. DECKING 16' ON CENTER OFFSET TRIPLE WIDE CENTER SECTION PEAK . —� SITE INSTALLED DECKING ON PIT108 NO BLOCKING REQUIRED TRUSS SECTION & REMINDER Of BOTH OUTSIDE SECTIONS (2 FULL AT CONTINUOUS PANEL $ ROWS OF SHEATHING) SEAMS BETWEEN TRUSSES. SEE OTHER DETAILS TO SECURE TRIPLE WIDE MARRIAGE LINE SITE INSTALLED PITCHED TRUSSES MIN. WIDTH PER SHEATHING, REQUIREMENT MANUF. INSTALLED DECKING TO HERE bi APA RATED ROOF DECKING (OR EQUAL) WIN020NE III ALL EXPOSURES (110 MPH) 20 PSF ROOF 10 PSF O.L. NOTES ENGNEER APPROVAL• DAM APPROVAL 1. 1/8' MAXIMUM GAP AND 1/16' MINIMUM GAP BETWEEN DECKING PERPENDICULAR AND PARALLEL TO TRUSSES. APPROVED BY 2. ROOF DECKING MATERIAL TO 6E 7/16" APA RATED ROOF (24/0 Revised SPAN RATED) DECKING (EQUAL OR BETTER). .)OhTI t'r.'vJ;��:�. � - Oct 29,2007 3. OTHER TRIPLE WIDE SECTION (NOT SHOWN) WILL BE THE }2F-19,:«oi1:"I'; ,tiff. A SAME DECKING PATTERN. INC.V - FEDEWLL YANUFA(.TURED HOME 4. FASTEN DECKING TO ROOF FRAMING WITH 7/16 X 1 1/2' X 15 CONSTRUCTION AND SAFETY STANDARDS GA. STAPLES AT 3- O/C EDGES AND FIELD N019CE: DRANN 8Y: DA1E: REV. Lan: JAC0BSEN HOMES 1NESESrEofl MIS ANDMUM AM O.A. 10-24-07 CP40WL PRIEIARY. AND COaAnE ft ORAINNC nnF YATEAIAES DF'ucaM YAAAFACRRIIG ON SITE PITCHED ROOF DECKING INST. P.O. BOX ma xG SUGa WERIAlS AX PROW= 10 THE SAFETY HAROCK FLORIDA U695 UEMt tat VWm NOIN5"OW eE WAVMG MMBfR PHONE (727) 725-1138 WT corcom . as SIMI tract owm AD—PR-7004 ON SITE PITCHED ROOF DETAILS IMPORTANT NOTICE THE ON SITE PITCHED ROOF INSTALLATION (INCLUDING SHINGLES AND CAP) MUST BE COMPLETED .WITHIN 60 DAYS OF DELIVERY TO THE HOME SITE.. FOR ATTACHMENT OF ALL VENTING (INCLUDES 12 EXHAUST & ROOF), SOLAR TUBES AND PLUMBING 4 VENTS SEE AD-PR-7007 & 7009. MAX. ROOF` SLOPE FOR ROOF DECKING. DETAILS . -, SEE AD-PR-7004. FOR ATTACHMENT OF PITCHED RAFTER TO TRIPLE WIDE SEE FOR ROOFING DETAILS SEE AD-PR-7002 -SEE AD-PR-7008 SHIP THIS SEC. LOOSE E (SITE INSTALLED) . . >-�------------- - - - - - - FOR OVERHANGS SEE AD-PR-7003. L- FACTORY INSTALLED RAFTERS (CENTER SECTION) REMOVE ALL FACTORY INSTALLED . �--- FOR ROOF VENTING BOTH FACTORY - POLYVINYL BEFORE INSTALLING THE AND ON SITE SEE AD-PR-7005 & 7006 ON. SITE PITCHED ROOF RAFTERS I III CENTER SECTION OF TRIPLE WIDE TYPICAL TRIPLE WIDE HOME REF. PG.IW-07-0011 WITH SITE INSTALLED PITCHED FOR FASTENING CENTER SECTION RAFTERS DAPIA APPROVAL: NOTES: APPROVED BY Revised IN occtl 25,2007 174I . FEDERALMANUFACTUREO HOME CONSTRICTION AND SAFETY STANDARDS NOTICE DRAIN BY: DATE: REV. LETTER: JACOBSEN HOMES THESE sKm,u>Iom me mTTWTs A O.A. 10-24-07 OMMAL, PROPKTARY, AND CONFIDENTIAL DRAWING TITLE: ❑ uATRALS OF Kam+ uANUFACn IM ' ON SITE PITCHED ROOF DETAILS u n_ P.O. BOX 36B WC. M YATM LLS ARE PRO40 TO THE III�IIII^III SAFETY HARBOR. FLORIDA 34695 RE"T FOR XORC Ty%pW Am WST BE DRAWING NUMBER: PHONE (727) 726-1133 KEPT OORRpf1+n4L AND SECTST RIOT OTTERS AD -PR- 7001 ADDENDUM NORMAL TIE -DOWN SPACING TABLES 1 ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE �+1 MIN. WIND ZONE II WIND ZONE III Y:N.OTY. EA. END OF ANCHOR YIN.OTY EA. END OF ANCHOR ANGLE �J S� FLOOR O� WIDTH EA. SECTION YIN. IN. 9 EA. SECTION YIN. B 20'-0' 2 36' 2 45' 24'-0" 2 46' 2 60' � 254 2 50' 3 38, 26'-8' 2 54' 3 41' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DEL HEAD ANCHOR ANGLE SPACING DBL HEAD LOAD ANDIOR ANGLE FLOOR EAVE WIDTH OVERHANG LOAD 26-0' 12' 8'-0" 31501 40'-50' 6'-8' 3150# 40'-50' 24'-O' 12' 8'-0' 31501 40'-50' 6'-8' 3150# 40'-50' 254 12' 8'-0' 1 31501 40'-50' 6'-8' 3150# 40'-50' 26'-8' 12' 8'_p• 315D# 40-50' 6'-8' 31504 40'-50' LONGITUDINAL TIE —DOWN SPACING TABLE MIN. WIND ZONE II LAND ZONE III FLOOR YIN. OTY. EA. END OF ANCHOR AN MIN. OTY. EA. END OFANGLE,v ANCHOR 1- WIDTH EA. SEC110N MIN.. D EA. SECTION YIN..D 20'-0' 2 50' 2 68' 24'-0' 2 70' 3 50' �4 j y 3 45' 3 60' 3 45' 3 60' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE Ilt SPACING DBL HOD ANCHOR ANGLE SPACING DBL HEAD ANCHOR ANGLE FLOOR EAVE WIDTH OVERHANG LOAD LOAD 20'-0' 12" 5-4' 31501 40'-45' 4'-0' 3150# 40'-50' 24'-0' 12' 5'-4' 3150# 40'-50' 4'-0' 3150# 40'-50' 25'-4' 12" 64 31501 40'-50' 4'-0' 31501 40'-50' 26'-8' 12' 5'4 31501 40'-50' L%1L 11,111,E '-0' 3150# NOTES: ENGINEER` O �i��i � Q� G • \ S T Eq . `f,''•� DAPIA APPROVAL• 1. SEE AD—TD—D001 FOR ADDITIONAL REOUIREMENTS. ' v =_APPROVED Q No. O'. BY 2. SEE AD—TO-0011 FOR MAXIMUM PIER HEIGHTS REQUIRED FOR THE LOADS TABULATED ABOW- ENE8 5 *A �o�;•• xq OF NINC, E JACOBSEN HOMES NOTICE: THESE SPECInunONS AND DRAWNGS ARE WONAL, PROPRIETARY. AND CONFIDENTIAL 1CRITW1W. C.L.Y. DATE: 5-30-95 REV. LETTER: DRAYANG TITLE: MATERIALS OF JACOBSEN YAPAJFACiIXtING NORM. SPACING TABLES 1` P.O. BOX 368 SAFETY HARBOR. FLORIDA 34695 WC. SUOi MATERIALS ARE PRONDED TO THE REDPENT FOR SKCFC RRFOSFS Arno W= BE CONFMTVL AHD SECRET FROM OTN M // ORAWNG NUMBER AD-TD-0010 PHONE (813) 726-1138 lut 29 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS NAX PER AD-TD-MIO TABLE PER AD-TD-0010 TABLE PER AD-M-0010 TABLE PER AD-TD-0010 TABLE FER AD-TD-DOIO TABLE MAX TYPICAL CROSS SECTION SHOWING TIEDOWNS FIGURE 1.0 SEE FIGURE 2.0 FOR ALTERNATE TIE -DORM MMOD FIGURE 1.1 SEE FIGURE 5.0 FOR ALTERNATE TIE-DOW NOTES: ENIIeEER 1. SEE AD—TD-0010 FOR SPACING TABLES 2. SEE AD—TD-0010 FOR QUANITY OF LONGITUDIAL TIE —DOWN STRAPS REQUIRED. 3. SEE OTTIER DETAILS FOR BLOCIONG (PIER) QUANTITY AND OTHER REOUIREA1ENTS. 4. SEE AD—TD-0001 FOR ADDITIONAL REQUIREMENTS 5. ZONE 2/EXPOSURE 'C% 60'. MAXIMUM HEIGHT ZONE 2/E:XPOSURE TT': 44' MAXMUM HEIGHT ZONE 3/EXPOSURE V: 40' MAXMUM HEIGHT ZONE 3/EXPOSURE V: 36' MAXIMUM HEIGHT >;Qti N0. Fo a ENE8703571 =. S Tr SEE NOTE 5 FOR MXAAIM HEIGHT REF. CALCS: INC, JACOBSEN HOMES No77C& °�a�u�a►'' DATE: REV. LETTER THESE SPEanCATMS AND DRAINNtS ARE C.L.Y. 3-27-95 ORIGINAL. PROPRIETARY. AND CONFIDFHTIAL DRAWING TITLE: P.O. BOX 368 MA70 LLS OF JACOUMN MANUFACTURING FIGURES 1.0 AND 1.1 WC. SOON MATERIALS ARE PRONDED TO THE SAFETY HARBOR, FLORIDA 34695 RCCPENT Fat SPECFX RIRPM AND MUST BE DRAWING NUMBER PHONE (813) 726-1138 WT CptTMnk Alm SECRET TROY 07MM AD—TD-0011 30 ADDENDUM NORMAL TIE -DOWN SPACING TABLES ZONE II & III/EXP. C & D 1 �' LONGITUDINAL TIE -DOWN SPACING TABLE V 0� MIN. FLOOR WIDTH WIND ZONE II WIND ZONE III WIN. OTr. EA. END IO EA SECTION ANCHOR AN YIN.. A YIN. otr. A EN EA. IO EA SECTION MCHOR ANGLE YIN. B 12'-0 2 43* 2 55' 13'-4' 2 50 50, 2 68' �1 1� VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DEL ANCHOR ANGLE SPACING DBL HEAD LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 12'-0' 6' 8'-0' 31501 40'-50' 6'-8' 3150# 40'-50' 13'-4' 6' B'-0' 31501 40'-50' 6'-8' 3150# 40'-50' LONGITUDINAL TIE -DOWN SPACING TABLE n v MIN. WIND ZONE II WIND ZONE III . FLOOR WIDTH YIN. OTY. EA. END OF FA SECTION ANCHOR ANGLE YIN. B YIN oTY EA END OF EA. SECTION ANCHOR ANGLE YIN. B 12'-0 2 64' 3 47' 12'-0* 3 37' 4 33' 13'-4' 3 42' 3 1 55' 4 30' 1 4 1 38' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DB IL HEAD LOAD ANCHOR ANGLE SPACING DEL HEAD LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 12'-0* 6' 5-4' 31501 40'-45' 4'-0' 3150# 40'-50' 13'-4" 6' 1 5'-4' 31501 40'-50' 4'-0' 3150# 40'-50' I. SEE AD-TD-D001 FOR ADDITIONAL REQUIRELENTS 2. SEE AD-TD-0013 FOR MA)IMU►J PIER HEIGHTS REQUIRED FOR THE LOADS TABULATED ABOVE.ENE8703571 J. MAX EAVE OVERHANG REFERS 70 OVERHANG AT SIDEWALL NOT FRONT OR REAR. 4. ABOVE TABLES APPLY TO 160' FLOOR OR 144' FLOOR WIDTHS WITH 95 1/2' I -BEAU SPACING, 96• MA)IYU1J SIDEWALL HEIGHT AND 6• MAXIMUM SIDE OVERHANG (6' OVERHANG MAX EACH SIDE OF UNIT) ENGINE`R, �•'/� ��` O •'''1ST •��G RFo FZ No. = STA F S1l7fMl � •� � � �������; ' ��/� QN. .''�`J�'`�`�• i��� S '' • •..... • (j `�� DANA APPROVALNOTES: APPROVED BY r T 5 INC WMJKTIf�N]E cosutr.'rrN°s�RrraDbroO JACOBSEN HOMES „ P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 NOTICE: �brrT 11 THESE SPE:CIFICATMS AND DRAMNES ARE' DtadNN. PKM7W AND CONFIDENTIAL MATERIALS OF 1406SEN YAAIFACTURING WC SUCH UATEMS ARE PROVIDED TO THE RECPIEW FOR S?EUX PYPOSFS NO W 57 BE OUT COWEbIM PO 1100 FROU OTIM 1111�� C.L.Y. DATE: 5-30-95 REV. LETTER: / /H` DRAWING TITLE: NORM. SPACING TABLES DRAWNG NUMBER: AD-TD-0012 31 TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS TYPICAL CROSS SECTION SHOWING TIEDOWNS ADDENDUM TIE -DOWN SYSTEM FIGURE 1.2 SEE FIGURE 2.0 FOR ALTERNATE T!E-DOWN MEMOD ANGLE ANGiE FIGURE 1.3 SEE FIGURE 7.0 FOR ALTERNATE TIE-DORN MOD SEE NOTE 5 FOR MAXIMUM HEIGHT NOTES: ENgNEE`R```(�jAROIyWf��I��/' DAPIA APPROVAL- . 1. SEE AD-TD-0012 FOR SPACING TABLES AND NOTES.��``, \",.`' •DOF'''�'�i 2 SEE AD-TD-0012 FOR OUANITY OF LONGIMDIAL TIE -DOWN STRAPS REWIRED. G�STEH • O� ����� APPROVED BY 3. SEE OTHER DETAILS FOR BLDCMNG (PIER) QUANTITY AND OTHER REQUIREMENTS. N0. O 4. SEE AD-TD-0001 FOR ADDITIONAL REQUIREMENTS. — ENE870357 JAN 'i -5. ZONE 2/EXPOSURE V: 30' MAXIMUM HEIGHT ir INC ZONE 2/EXPOSURE V: 48' MAXIMUM HEIGHT AT^ OF :•� " FEDtKk MMWAMM HM ZONE 3/EXPOSURE V: 28' MAXIMUM HEIGHT �O'., �� �� ma�wtirannms�tErcsaraln0 ZONE 3/EXPOSURE 'D': 60• MAXIMUM HEIGHT �4 �!� •.,' Y p I P► . �• \��.�� r1ozTctw'aifM� 1V..��Rr DaTE REV. LETTER: JACOBSEN HOMES THESE SKanCATIONS AHD DRAW MII �►0a0 C.L.Y. 5-19-95 ■ MATERIALS A. PROPRIETARY, AND UFAC TL4LIMIG DRAWING TITLE:FIGURES 1.2 AND 1.3 A P.O. BOX 368 MATERIALS OF JAC08SEN M,ANUFACTURINC „❑ . WC. 9Ia1 MATERIALS ARE PROMM TO THE SAFETY HARBOR, FLORIDA 34695 REOPENT Fat SUM Pi"M AND WbT BE DRAWING NUMBER: PHONE (813) 726-1138 IVT COIFMTM AID SFatET Ri011 ONERS AD-TD-0013 32 ADDENDUM ALTERNATE TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION cunmkii, nr_nnwm cperimm MAX nK AL -Wu ly �ro.t ....... ... ...... .....- . _. .- �- ---- --- FIGURE 2.0 SEE FIGURES 1.1 AND 1.3 FOR TYP. CROSS -SECTIONS) ..tuunuf,.. NOTES: WL, ��EAQ �j\S E/� �i �: FQ ? DAAA APPROVAL AFr ROVED BY 1. SEE AD-TO-0010 FOR SPACING TABLES REQUIRED. 4;`` No. = ENc8703571 c 2 SEE AD-.TD_0DI0 FOR QuA►aT( OF LONG UDIAL TIE-DOYN STRAPS _ g 3. SEE OTHER DETAILS FOR BLDCIONG (PIER) QUANTITY AND OTHER REQUIREMENTS =_ !• - 4. SEE AD-TD-0001 FOR ADDITIONAL REQUIREMENTS INC. � caaTR,cranoswtnsaln�rm A�1cN JACOBSEN HOMES NOTICE: THESE=EaflanONS AND DRANMNGS ARE ORIGINAL, PROPMETARY. AND CONFWTIAL DRAWN BY: C.L.Y. DATE: 5-19-95 REV. LETTER: DRAWING TITLE MATERIALS OF JACOBSEN MANUFACTURING FIGURE 2.0 P.O. BOX 368 „ SAFETY HARBOR. FLORIDA 34695 w_ SUCH MATERIALS APE PW40 TO THE REOMT FCR 9EGM P5KSES AID MUST DE FROM DMn DRAWING NUMBER: - AO—TD-0014 PHONE (613) 726-1138 APT CW6DLT+nAL ADD MOO 33 ADDENDUM ALTERNATE TIE -DOWN SYSTEM(S) ALTERNATE LONGITUDINAL TIE-DOWIN INSTALLATION METHODS SIDE NEW OF MAIN FRAME 'r-DOWN STRAP I SCE OTHER DETAILS FOR TIE -DO M STRAP SPECIFICATIONS, APPROVED ANCHOR BcV = TO MAIN I -BEAN (SEE OTHER DETAILS SEE AD-Tit-0200 FOR FOR WELDNG) TO BE NSTALLEi RADIUS CLIP DL7ALS AT THE FACTORY. (REOUIRED INS LOCATION). (MIN. 31501 INCRAING [DESIGN] LOAD AND 47251 ULTWA7E LOAD.) o GROUND ANCHOR ° SEE OTHER DETAILS FOR SILL~ ANGLE AND OTHER INSTALLATION NOTES. SOLID HEADER (CROSSMEMBER) �.� SEE AD-T'D-0200 FOR ! RADIUS CUP DETAILS (REQUIRED THIS LDCATION). SIDE Y,EW NOTES: 1. SEE AD-TD-0010 FOR SPACING TABLES. 2. SEE AD-M-0010 FOR QUANITY OF LONGITUDIAL TIE -DOWN STRAPS REOU:RED. 3. SEE OTHER DETAILS FOR BLOCKING (PIER) OUANTITY AND OTHER REOUOTEAIENTS. 4. SEE AD-ID-0001 FOR ADDITIONAL REOUIREIAENTS. FIG URE 2.1 3' X 3/4' (t 1/2)0 FRONT VIEW CUT INTO HEADER FOR STRAP ATTACHMENT. . MUST BE LOCATED WWTHN 5' OF MAIN (FACTORY CUT) CHASSIS 1-BEAM. SEE AD-TD--0200 FOR RADIUS CLIP DETAILS (REQCI RED THIS LOCATION). 5' uAx TIE -DOWN STRAP SE OTHER CSAJLS FOR RE -DOWN STRAP SPECIFICATIONS GROUND ANCHOR' SEE OTHER DETAILS FOR SIZE, ANGLE AND OVER INSTALLATION NC-S. hUR APPROVAL::1- I- Nca*. +,^ramA It ��iAArum>InY�,\. ANCHOR BRACKET AND TL-DOWN DEVICES ARE CERTIFIED BY OTiOS FIGURE 2.2 DARA APPROVAL: None JACOBSEN HOMES T� !PEUACA`DNS ANO CRAW)& ARE C.L.Y. fi-13-95 ORGMAL FRCPR,ETART. AN) CGrWTIAL DRAWING TITLE: OWN BDX 368 NAr� OF JACOBSEN "A""rA001SH3 FIGURES 2.1 & 2.2 MG SUCH MAT'UMS A;[ PROYM TO BE SAFETY HARBOR, FLORIDA 34695 RLa OT roR SPECK Pe Frogs AAo LUST !!E DRAWING NVUBER: P.O.PHC.VE (813) 726-1138 W11 MODEM& ka SECRET rRoU onw AD-TD-0015 ii LONGITUDINAL STRAP ATTACHMENT TYPICAL FRAME I -BEAU TYPICAL LONGITUDWAL ANCHOR STRAP (FIELD INSTALLED) NOTES:.. 1. SEE OTHER DETAILS FOR STRAP PROTECTION AT ALL SHARP CORNERS 2. ALL STRAPS TO BE TYPE 1, FINISH 0, GRADE 1 STEEL STRAPPING, 1 1/4" WIDE AND 0.035 INCHES IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D 3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL. AND SEALS. CATOR BEAM CLAMP, MANUFACURED BY TIE -DOWN ENGINEERING, PART 159011 (SEE MANUFACTURERS INSTRUCTIONS FOR COMPLETE INSTALLATION DETAILS) DAPIA APPNUVAL ARPROVED BY j1pi s, 5.20 INC. MANUFACTURED HOME CTION AND SAFETYSTANDARDS NOTICE: DRAWN BY: DATE: REV. LETTER:' JACOBSEN HOMES THESE SPEOMATIONS AND DRAWINGS ARE M.T. 6-12-01 ORIGIM PROPRIETARY, MID CONFIDENTIAL DRAWING TITLE: MATERIALS OF JACOBSEN MANUFACTURING LONGITUDINAL STRAP ATTACHMENT P.O. BOX 368 ` INC. SUCH MATERIALS ARE PROMDED TO THE SAFM HARBOR. FLORIDA 34695 REaRENT Fm S wx PURFM AND MUST BE DRAWING NUMBER: PHONE (727) 726-1138 REPT CONE oDMAAL AND SECRET TROY OTHERS AD-TD-OD16 35 ADDENDUM OFFSET UNIT TIE -DOWN SPACING TABLES ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III V FLOOR WIDTH MIN. ott. EA. END OF EA SECTION ANCHOR ANGLE MIN. a MIN. OTY. EA. END EA SECTION ANCHOR ANGLE uDl e 10'-0' 2 44' 2 56' •�;� 12'-0' 2 57' 3 42' 13'-4' 3 38' 3 50' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III FLOOR WIDTH SAVE OVERHANG SPACING DSL HEAD LOAD ANCHOR ANGLE SPACING DEL HEAD LOAD ANCHOR ANGLE 1O'—O" 12" 4'-0' 31501 40'-50' 4'-0' 31501 40'-50' 12'-0" 12" 4'-0' 30001 40'-50' 4'-0' 3150# 40'-50' 13'-4" 12' 5-3' 31501 1 40'-50' 4'-0' 3D00 j 40'-50' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III * S�� VV �U FLOOR WIDTH MIN. OTT. EA. END OF EA sEcnoN EA..�•�O ANCHOR ANGLE um. a UK OTY. EA. END OF EA. SECTION ANCHOR ANGLE UK e 10'-0' 2 64' 3 46' 12'-0• 3 50' 3 68' 13'-4' 3 58' 4 48' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III FLOOR WIDTH EAVE OVERHANG SPACING DBL HEAD LOAD ANCHOR ANGLE SPACING D& o� ANCHOR ANGLE 10'-0" 12' 4'-0' 3150# 40'-50' 2'-8• 3150# 40'-50' 12'-0" 12' 4'-0' 3100# 40'-50' 2'-8' 3150# 40'-50' 13'-4" 12" 4'-0' 3065,1 40'-50' 2'-8' 40'-50' NOTES: 1. OFFSET SECTION WITH THE MARRIAGE LINE WALL EXTEND94G BEYOND THE ENDWALL OF'G15T+'A� THE ADJACENT SECTIO14 MUST BE TIED DOWN AT ME MARRIAGE LINE IN ACCORDANCE WITH THE TABLES ABOVE: THE SIDEWALL SIDE AND THE ADJACENT SECTION(S) ARE T BE TIED DOVR4IN ACCORDANCE WITH THE NORMAL SPACING TABLES (AD-TD-D010). ; 2. SEE AD-M-000I FOR ADDITIONAL REQUIREMENTS. 3. SEE AD-M-0021 FOR MAXIMUM PIER HEIGHT REWIRED FOR THE LOADS TABULATED ABOVE EN°:�� ��"bA �.' Q� ti• . C� '• ;• y. -0' ;• _r !. iC`''•. ^� Yam•'' �Z FED . ?� l /tire. • �� �� CO �3r0�0g01 VA "t-D BY REVISED SEP 0 9 15 INC. RAL MANUFACTURED HOME STRUCTION AND SAFETY STANDA! "ElElJACOBSEN HOMES BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 NOTICE: �S ARE IHESE sPEanunoNs AND DaAwJlcs ARE ORICINAI. PROPP.IETARY, AND CON110EN11AL INC. SJ i of JACoeSEN MANUFACTURING INC. Ala MATERIALS ARE PRONDED TO THE REoP�•r FCR SPErnC RAPOSF.S AID WST BE WT COIdoEHnAL MO SECRET FRW 0MRS i �L � : R.R. DATE 8-27-96 REV, LETTER: DRAWING TITLE:P.O. OFFSET SPACING TABLES DRAWING NUMBER: AD—TO-0020 CIS u ADDENDUM a r OFFSET UNIT TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) CNnvw TIF-nnm CPAL'INGS till Fib VIA 1, PIA FIN PER AD-RI-0020 TABLE MAIL . PER AD-TD-OD10 TABLE PER AD-TD-D010 TABLE OFFSET SECTION OF UNIT FIGURE 3.0 SEE FIGURE 4.0 FOR ALTERNATE TIE -DOWN 01011 TYP. CROSS SECTION(S) SHOWING TIEDOWNS SEE NOTE 5 FOR Mmll "I", (TABLES ON AD-ID-OD20 DM APPLY TO THIM STANDARD MULTI -WIDE SECTIONS OF THE UNIT -SEE NOTE 1. AD-TO-0020.1 TIP. FLOOR SYSU-7 ANCHOR ANGLE PER AD-10-0010 TABLE MAIL TYR ANCHOR ANGLE ANGLE ANGLE FIGURE 3.1 FIGURE 3.2 SEE FIGURE 6.0 FOR ALTERNATE TIE-DOAN NE HDD p1 WHI VAIM, ALTERNATE TIE-DDVN METHOD NOTES: F�a` O 0 O ��� DAPIA APPROVAL • \ No. APPROVED BY 1. SEE AD-TD-0020 FOR SPACING TABLES (OFFSET SECTION ONLY). �� ; '•G AF '••?/ '- 2. SEE AD-TD-0020 FOR QUANITY OF LONC1UDIAL TIE -DOWN STRAPS REWQ�IRED. - N No. •: (OFFSET SECTION ONLY) ISEE OTHER DETAILS FOR BLOCKING (PIER) OUAN11TY AND 07HER-REQUIREMENTS. _7NI*P L` 3 4. SEE AD-TD-0001 FOR ADDITIONAL REQUIREMENTS. fo INC, 5. ZONE 2/EXPOSURE V.- W MAXIMUM HEIGHTZONE 'I •••: Y� \�•"• \` �� CR6ilpR,TlU1xm5�Ff7T ZONE 3ZONE �OSURE OSUREV.- 32' MAXIMUM HEIGHT (44' 024' WIDE MIN.) ��El JACOBSEN HOMES NO= THESE SPEQFlCARDNS AND DRAWINGS ARE urtnnn or C.L.Y. unit 5-11-95 rccv. cciicn: P.O. BOX 368 ORIGINAL. PROPRIETARY, AND CONFIDENTIAL MATERIALS MATERIALS OF JACOF15fN MANUFACTURING - ORABING TITLE FIG. 3.0, 3.1 & 3.2 INC. SUCH MATERIALS ARE PROVIDED TO THE �0�� SAFETY PHONE (813) FLORIDA 26 1138 95 C CAPSEPag5�OUM M DRAWING NUMBER: AD-TD-0021 37 ADDENDUM ALTERNATE OFFSET UNIT TIE-DOtiUN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SHOWING TIE-GOA`J SPACINGS r FIGURE 4.0 SEE FIGURES 3.1 AND 3.2 FOR TYP. CROSS-SECTION ,,,,,,,11I1E1FFp NOTES: `Er slik OV . F �i�� DAPIA APPROVAL:I. SEE AD—m-0020 FOR SPACL4� TABLES (OFFSET SECTION ONLY). `�OCr•`�G�STERFOF2•�, APPROVED BY 2 (OFFSETSECTIONSECTIONO LLD(»QUAN!TY OF LON01UDIA1 TIE—DOlttl STRAPS 1?EOIJIR£D. ? NE8703571 3. SEE OTHER DETAILS FOR BLOOCNC (PIER) QUANTITY AND OTHER REOUIRDAENTS. 4. SEE AD-1D—OD01 FOR ADDITIOGAL REQUIREMENTS Qj' II C • � �. �/ � lE:FWI�ueJFCi1f1FD IR7E ��, �AN • � �` co��R,aaxosAFSTrsn�cw� JACOBSEN HOMES FE=tHESE P.O. 90x 368 N017CE ""' seEOF1CATIDHS AND DRAMHCS ARE ORIpNN.. PROPRIEIM. AHD vwgI(>ENTIAL MATERIALS OF MCOM YAHIFACTt"O oRANN BY: , C.L1". DATE: 5-11-95 REV. LETTER: n DRAWING TITLE: FIG. 4.0 „ SAFETY H tR^c,R. FLORIDA 34695 DID. SU CH WATEIMS ARE V8mm TO THE RECPQTT FOR TECFIO PIIS'On me wm OE 'Hl DRAWING NUMBER PHONE (813) 726-1138 12PT CDWMTK AND SEOV ERN OTIQ6 AD-TD-0022 38 ADDENDUM vUg� ALTERNATEI TIE -DOWN SPACING TABLES � II &III/EXP. C & D / LONGITUDINAL TIE -DOWN SPACING TABLE E+1 MIN. NAND ZONE II WIND ZONE III MIN. OTY. ANCHOR MIN OTY. ANCHOR r �J FLOOR EA. END ON N EA. END OF NGTE WIDTH EA SECTION MIN.. A EA SECTION MIN. B O� 20'-0' 2 46 ' 2 45' 24' -0' 2 46' 2 60' 25'-4' 2 50, 2 67' 30, VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DBL HEAD ANCHOR ANGLE SPACING DBL HEAD LOAD ANCHOR ANGLE FLOOR SAVE WIDTH OVERHANG LOAD 20'-0' 12' 4'-0' 36701 20' 4'-0' 3900# 20' 24'-0' 12' 4'-O' 3700# 20' 4'-0' 3950# 20' 25'4 12' 6'-8' 4DO01 15' 4'-0' 39501 22' 26'-8' 12' 6'-8' 39501 28' 4'-0' 1 3950# 22' LONGITUDINAL TIE -DOWN SPACING TABLE MIN WIND ZONE II WIND ZONE III vFLOOR MIN.OTY. EA. END O ANCHOR MIN.OTY. EA. END ANCHOR ANGLE W1DTH EA SECTIONN IN. Y01. 0 ON EA SECTION YIN. 0 O� 20'-0' 2 50' N/A N/A 24'-0- 2 70' N/A N/A �j 25'-4' 3 42' N/A N/A 26'-8' N/A N/A N/A N/A VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPADNG m HEAD ANCHOR ANGLE SPACING DBL HEAD ANCHORANGLE FLOOR EAVE WIDTH OVERHANG LOAD 20'-0' 12' 4'-0' 40001 20' N/A N/A N/A 24'-0' 12' 4'-0' 40001 24' N/A N/A N/A 25'-4' 12' 4'-0' 1 40001 26' N/A N/A N/A 26'-8' 12' 4'-0' 1 4000 21 , ,,,,, , N/A N/A N/A NOTES: EN(;NgfI XRMUDQ8 DAPIA APPROVAL- ' 9F0 - - . 1. SEE AD-TD-0001 FOR ADDITIONAL REQUIREMENTS .-I/ LG� ^O 2 SEE AD FOR MAXIMUM PIER HEIGHT REWIRED FOR THE LOADS TABULATED Q, :• EI�E8?03571 ': ;-' ; --•:? ABOVE. • �• 3. 20 WIDES -82' MAXIMUM I -BEAM SPACING ONLY. 4. 4' MAXIMUM INSET TO ANCHOR HEADS (SEE AD-TD-0031). '•���`�• • /Ni�4�� ,��:� _., •_, •,,.I �...:.. —, JACOBSEN HOMES NOTICE '11IIT 14RAW THESE SPEOKATIONS AND DRAW-M ARE C.L.Y. DATE 6-13-95 REV. LETTER: TITLE ALT. SPACING TABLES OR10NAL PROPRIETARY. AND CONTID01➢AL DRAWING MATERIALS OF JACOBS£N MANUFAC11JM P.O. eox 36a SAFETY HARBOR, FLORIDA 34695 INC. 9U01 MATERIALS ARE PROVIDED 70 THE RECANT FOR SPECi1C Pl1RPW"Z51 K DRAWING NUMBER: AD- TD-0030 PHONE (813) 726-1138 WT COFWnAL Arm SECRET rROM OTHERS 39 VISO ALTERNATE TYPICAL CROSS SECTION SHOWING TIEDOWNS ADDENDUM TIE -DOWN SYSTEM(S) SEE NOTE 4 FOR MA)NUN HEIGHT 4' Max NSEr FIGURE 5.0 SRE FIGURE 1.1 FOR RECOM ODED TIE-DO11 METHOD IMPORTANT NOTICE: THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS THEN USING THIS TIE -DOWN CONFIGURATION A STYLE CREST PRODUCTS MODEL 57SH (TYPE 2). AUGER ANCHOR TTTH A DESIGN IDAD (WORKING IDAD) RATING OF 4,000 POUNDS AND AN ULTBLATE LOAD RATING OF 6,0D0 POUNDS MUST BE USED. AN EQUIVII.ANT ANCHOR MEETING THE ABOVE SPECIFICATIONS MADE BY ANOTHER MANUFACTURER MAY BE USED IN LIEU OF THE STYLE CREST PRODUCTS ANCHOR NOTES: THE ALTERNATE TIE -DOWN METHODS SHOWN ABOVE ARE ACCEPTABLE FOR USE IN ALL HIND ZONES AND IN BOTH EXPOSURE 'C' AND EXPOSURE '0'. HOWEVER. BY 1. SEE AD-TD-0001 FOR ADDITIONAL PEOUIREMENTS. INSTALLING THE FRAME TIE -DOWN STRAPS AT THE 'OUTBOARD' I -BEAM THE MAX. 2. SEE OTHER DETAILS FOR BLOCKING (PIER) OUANTITY AND OTHER REQUIREMENTS HEIGHT OFF THE GROUND IS GREATLY REDUCED. SEE OTHER DETAILS FOR THE 3. FOR FIGURE 5.0 SEE ALTERNATE ME -DOWN SPACING TABLES (AD-TD-0030). RECOMMENDED METHODS FOR INSTALLING FRAME TIE-DOVMS 4. ZONE 2/EXPOSURE 'C% 31: MAX ..UM HEIGHT MAXIMIJu ENCtNTM APPROVAL�T •� ' •;% � �N DAPIA APPROVAL' 2/EXPOSURE'D': 27' HEIGHT 'C': �� p �1STFy' �'�� rrrr _ ZONE 3/EXPOSURE 30' MAXDWu HEIGHT 'D': .• , ' Fiy ZONE 3/EXPOSURE THIS APP'JCA71ON IS NOT APPLICABLE. Q�' CIO. _t4ES?O1riT _ T�/J�T JACOBSEN HOMES NOTICE "` THESE SPEanCATIDNSANDDRAVINfSARE :DRAWN BY: C.L.Y. 1 DATE 6-13-95 REV. LETTER: OMONAL. PROPRIETARY. AND CONMENTUL uATETMAIS OF JACOBSEN NANUFACIMNG DRAWING TITLE' FIG. 5.0 „❑ P.O. BOX 368 MC. SUCH NATEM" ARE PRONDED TO THE SAFETY PHONEHARBOR. FLORIDA 726 1138 95 npT O wnk me SECIV � r m DRAWING NUMBER' AD-TD-0031 40 �E ADDENDUM ALT. OFFSET UNIT TIE -DOWN SPACING TABLES & 6 1 6 QQQ ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE MIN I IND ZONE II WIND ZONE III WIN- OTY. ANCHOR MIN. OTY. ANCHOR FLOOR 'MDTH EA END OF N EA ENDANGLE lV �Q O� EA SECTION MIN. IN. A EA SECTIOC N MIN. 6 20'-0" N/A N/A N/A N/A 24'-0" 2 42' 2 53' 25'-4' 2 45' 2 58' 26'-8' 2 48' 3 370 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DELHEAD LOAD ANCHOR ANGLE SPACING HEADE LOAD ANCHOR ANGLEWIDTH FLOOR SAVE OVERHANG 20'-0' 12' N/A N/A N/A N/A N/A N/A 24'-0' 12' 4'-0' 40DOj 20'-30' 4'-0' 4000$ 20`-30' . 25'-4' 12' 4'-0'1 40DO j 20'-30' 4'-0' 40001 20'-30' 26'-8" 12' 4'-0' 40001 20'-30' .4'-0' 4000# 25'-30' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III MIN.OTY. ANCHOR MIN.OTY. ANCHOR FLOOR ` S Q MOTH EA END OF ANGLE EA. END O 0� EA SECTION MIN. a EA. SECTIONSECTIONN IN. MIN. e 20'-0' N/A N/A N/A N/A 24'-0" 2 60' 3 45' 25'-4' 2 66' 3 1 48' 26'-8' 3 41 3 - 52' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DBL HEAD Low ANCHOR ANGLE SPACING DEL � ANCHOR ANGLE FLOOR WIDTH SAVE OVERHANG 20'4 12' N/A N/A N/A N/A N/A N/A 24'-0' 12' 3'-8' 40001 20'-30' 2'-8' 4000# 20'-30' 254 12' 4'-0' 40001 257-30' S-2' 40001 15t-30' 26'-8' 12' 4'-0' 40001 25'-30' S-2' 4000# 25'-30' NOTES:ENGINEER I_`fi1oullfIrT'A, DAPIA APPROVAL C"DO co BY 1. OFFSET SECTION WITH THE MARRIAGE LINE WALL EXTENDING BEYOND THE ENDWALL OF ����APPROVED 13�: �S; ERF ' F� THE ADJACENT SECTION MUST BE TIED DOWN AT THE MARRIAGE LINE IN ACCORDANCE WNTH THE TABLES ABOVE THE SIDEWALL SIDE AND THE ADJACENT SEC11ON(S) ARE TO : No.O ' JUN 1 4 ??� BE TIED DOWN IN ACCORDANCE WITH 1HE ALT. SPACING TABLES (AD-TD-0030). E re, "5 7 1- NAINC 2 SEE AD-TD-0001 FOR ADDITIONAL REQUIREMENTS ST�'T ' .` = rtL, .... :+uFFD wrF 3. SE-M-0033 FOR MAXIMUM PIER HEIGHT REOUIRED FOR THE LOADS TABULATED :�''Q� •, �jy` F�jy.�.c\�4.`` JACOBSEN HOMES NOTICE ��i� i= THESE S°EanCAnm AND DRAMNGS%': .O • �+++``' C.L.Y. DATE: 5-30-95 REV. LETTER: ORAWING nTLE: ALT. SPACING TABLES HE P.O. BOX 368 OFOGNAL, PROPRIETARY, AND CDNiIDENTul MATERIALS OF JAC'0MN MANUFACTURING SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 REOW FOR M aRnP ZRIN"MMO THE BE JVT CDIEWTIAL AND SEOIET FROM 0M DRAWING NUMBER: AD-TD-0032 41 r �oE 0-0, 1H NO lV0105. 1 ADDENDUM 5' 1- `o O � �E °��c R ,ALTERNATE TIE —DOWN SYSTEM TYP. CROSS SECTION(S) SHOWING TIEDOWNS ANOE MOLE FIGURE 6.0 SEE FIGURE 3.1 FOR RECOMMENDED TIE -DOWN METHOD SEE NOTE 5 FOR ROM HEIGHT (TABES ON AD-TD-OOS2 DDM APPLY TO THESE STMOARD Ylllll-Ml SECIM OF THE UNIT -SEE MOTE 1. AD-TD-M32.] TIP. FLOOR S131LL� /NNOHOR MCLE TYR FIGURE 6.1 SEE FIGURE 32 FOR RECOMMENDED TIE -DOWN METHOD IMPORTANT NOTICE: THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS WHEN USING THIS TIE-DOIN CONFIGURATION A STILE CREST PRODUCTS MODEL 57SH (TYPE 2), AUGER ANCHOR WITH A DESIGN IDAD (WORKING LOAD) RATING OF 4,000 POUNDS AND AN ULTBIATE IDAD RATING OF 6,ODO POUNDS MUST BE USED, AN EQUIVIIANT ANCHOR IffMNG THE ABOVE SPECIFICA71ONS MADE BY ANOTHER MANUFACTURER MAY BE USED IN LIEU OF THE STYLE EREST PRODUCTS ANCHOR. NOTES: 1. SEE AD-TD-0001 FOR ADDITIONAL REQUIREMENTS. 2. SEE OTHER DETAILS FOR BLOCKING (PIER) QUANTITY AND OTHER REWIREMENTS. 3. FOR FIGURE 6.0 SEE OFFSET UNIT TIE -DOWN SPACING TABLES (AD-TD-0020). 4. FOR FHAIRE 6.1 SEE NORMAL TlE-DOWN SPACING TABLES (AD-TD-0010). (ALSO SEE AD-m-0020 AND AD-M-0021) 5. ZONE 2/EXPOSURE 'C': 32' MAXIMUM HEIGHT ZONE 2"OSURE 'D% 24' MAXIMUM HEIGHT ZONE 3/ XPOSURE 'C': 24' MAXIMUM HEIGHT ZONE 3/EXPOSURE 'D': 28' MAXIMUM HEIGHT THE ALTERNATE TIE -DOWN METHODS SHOWN ABOVE ARE ACCEPTABLE FOR USE IN ALL WNO ZONES AND IN BOTH EXPOSURE 'C' AND EXPOSURE '0'. HOWEVER, BY INSTALLNG THE FRAME TIE -DOWN STRAPS AT THE 'OUTBOARD'I-BEAM THE MAX HEIGHT OFF THE GROUND IS GREATLY REDUCED. SEE 07HER DETAILS FOR THE RECOMMENDED METHODS FOR INSTALLING FRAME TIE -DOWNS. ENGINEER �WAC "" 'II/I, � NN C' DOF `�Q?�G\STEq" �Cc2 No. o r E87035ZL PPROVED BY NIPINC5 JACOBSEN HOMES THESE sPEon nOQNs AND DRAwNGs ' "���`` C.L.Y. DAT>= 5-30-95 � 'PER: . ONGINAL, PROPRIETART AND CCWDDITUL DRAWING TI1lE MATERIALS CF .IACOBSFN YAMIFACMNG P.O. BOX 368 DC SUCH MATERINs ,RE PROMED Tu THE FIG. 6.0 & 6.1 SAFETY HARBOR FLORIDA 34695 REOW FCR SPECrIC FIFt M NO Y151 K DRAWING NUMBER PHONE (813) 726-1138 KEPT CONITXNRAL AID SECRET 1RW OOWNS AD-TD-0033 42 ADDENDUM ALTERNATE TIE -DOWN SPACING TABLES ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE (+� MIN. WIND ZONE II WIND ZONE III MIN. OTY. ANCHOR MIN. OTY. ANCHOR �J FLOOR WIDTH EA END N EA END O ANGLE EA SECTION MIN. a EA sEcrlcN MIN. e 12'-0' 2 43' 2 55' 13'-4' 2 50' 2 68' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DBL HEAD LOAD ANCHOR ANGLE SPACING DBL HEAD LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 12'-0" 6" 4'4 37501 20' 4'4 3900# 22' IS-4' 6" 54 38501 25' 5'-4" 3960# 30' THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III MIN. OTY. ANCHOR MIN. OTT. ANCHOR FLOOR WIDTH EA ON ANGLE EA END OF ANGLE O EA SECTION MIN. A EA SECTION Mw B 12'-0' 2 64' 3 41' 12'-0' 3 37' 4 33' 13'-4' 3 42' 3 55' 30' 4 38' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DEL HEAD ANCHORANCHOR ANGLE SPACING DBL HEAD LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 12'-0" 6- 4'-0- 39501 25' 2'-8' 3930# 20' 13'-4" 6" 4'-0' 39601 25' 2'-8" 4000# 30' THIS ALTERNATE APPLICATION REQUIRES,,4,,,QOO POUND ANCHORS NOTES ENpr`E`�(t�_`R�J .O� ii �i DAPIA APPROVAL 1. SEE AD-TD-ODOI FOR ADDITIONAL REOUIREMENTS O?���STEg` F'L -,; O .•' APPROVED BY 2. SEE AD-TD-0036 FOR MAXIMUM PIER HEIGHTS REOUIRED FOR THE LOADS TABULATED ABOVE NO _ • ENE$703571 — �. — 1 5 7NIftA 3. MAX EAVE OVERHANG REFERS TO OVERHANG AT SIDEWALL NOT FRONT OR REAR.. 4. ABOVE TABLES APPLY TO 160' FLOOR OR 144" FLOOR WDTHS WITH 95 1/2'ION I z! �Q�'•. / �' �'� '• �•', I \J -BEAM SPACING, 96• MAXIMUM SIDEWALL HEIGHT AND 6" MAXMUM SIDE OVERHANG (6. OVERHANG MAX EACH SIDE OF LRTITJ JACOBSEN HOMES N097CE2 "llim TNEsE sKO11CATWNS AND DRANINCS ARE 1Y1tMt C.L.Y. DATE 5-30-95 REV. LETTER: DRAWING TITLE: ALT. SPACING TABLES ■ „ P.O. BOX 368 0MONAL. PROPRIETARY. AND CQtlMTIA MATERIALS OF JACOBSEN MMUFACTUPoNO PRONGED TO THE n SAFETY HARBOR, fLORIDA 34695 PHONE (813) 726-1138 WG SUCH MATERIALS ARE REOMT FOR SPECFX RF3 M AND 107 BE IVT CON WTUL AND SEM rRW OTHM /HV DRAWING NUMBER AD—TD-0040 43 owl",�000� RvQl� ADDENDUM ALTERNATE TYPICAL CROSS SECTION SHOWING TIEDOWNS TIE —DOWN SYSTEM ANGLE ANGLE FIGURE 7.0 SEE FIGURE L3 FOR RECOMMENDED TIE -DOWN METHOD IMPORTANT NOTICE: SEE NOTE 4 FOR MAIWUM HEID17 THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS WHEN USING DO M-DON CORFIGIJUTIOR A STYLE CREST PRODUCTS MODEL 57SH (TYPE 2). AUGER ANCHOR TIM A DESIGN WAD (TORKING LOAD) RATING OF 4,0DO POUNDS AND AN ULTIMATE WAD RATING OF SADO POUNDS MUST BE USED. AN EQUIVLANT ANCHOR MEETING THE ABOVE SPECIFICATIONS MADE BY ANOTHER MANUFACTURER MAY BE USED IN LIEU OF THE STYLE CREST PRODUCTS ANCHOR NOTES: THE ALTERNATE TIE -DOWN METHODS SHOWN ABOVE ARE ACCEPTABLE FOR USE IN I. SEE AD-TD-0001 FOR ADDITIONAL REOUIREMENTi ALL WIND ZONES AND IN BOTH EXPOSURE 'C' AND EXPOSURE '0'. HOWEVER, BY INSTALLING THE FRAME TIE -DOWN STRAPS AT THE 'OUTBOARD'I-BEAM THE MAX. 2. SEE 01HER DETAILS FOR BLOCIONG (PIER) OUANIITY AND OTHER REQUIREMENTS. HEIGHT OFF THE GROUND IS GREATLY REDUCED. SEE OTHER DETAILS FOR THE 3. FOR FIGURE 7.0 SEE ALTERNATE TIE -DOWN SPACING TABLES (AD-1D-OD35). RECOMMENDED METHODS FOR INSTALLING FRAME TIE -DOWNS 4. ZONE 2/EXPOSURE V: 38" MAXIMUM HEIGHT ZZONE ONE 3/EXPOSURE C: 28' MAXD/UM HEIGHT T ENGI D�F ' DAPoA APPROVAL /°X .��0 N '�srE' �F' APPROVED BY ZONE 3/EXPOSURE 'D': 28- MAXN IUM HEIGHTIN ) ; •'tpG 9F •. 2 .� 5. SEE AD-TD-0035 FOR ADDITIONAL NOTES . NEEI � •. OF IN •- = INC .O'' •� 4 co.�.+.:�i,.,wwmsTw®vao JACOBSEN HOMES MDDRAUMMAREE "'���� C.L.Y. DATA 5-30-95 REv LETTER: ORIDINAL• PROPMEYARY. AND CWnDOdIK DRAWWG TITLE: ^ „ P.O. BOX 368 MATERIALS OF JACDBSrJ1 MANUFACMUG FIG. 7.0 W_ S101 MATERIALS ARE PROVIDED TO THE SAFETY HARBOR. FLORIDA 34695 KWW FOIt SWM PUl W Am um K ORAWWG NUMBER PHONE (813) 726-1138 07 O NWIUL AW IOU FRW OKIM AD-TD-0041 44 ADDENDUM MISC. TIE -DOWN PROTECTION OF STRAP IS PROVIDED AT UPPER CORNERS BY FIRST WRAP OF STRAP. FRAME TIE -DOWN STRAP SHALL SEE DETAIL 'B' COME OFF THE 'TOP' OF THE I -BEAM SEE DETAIL V DETAIL 'A' IUCKLE WITH 3150# Y MINIMUM (DESIGN LOAD) DETAIL V PULL DOWN TIGHT TO GROUND ANCHOR INSTALL RADIUS CLIP (SEE AD-TD-0200) OR L/PIROTECT R DEVICE TO STRAP .AT ALL CORNERS. DETAIL 1 C' THIS TYPE OF PROTECTION MAY BE USED FOR T gjgRN,PT,i LONGITUDINAL TIE CONNECTIONS ALSO. V. STIJ� NOTES: `t l ..�a�RF : < '%� DAPIA APPROVAL• 1. SHOWN ABOVE IS ONLY ONE METHOD OF STRAP ATTACHMENT, = 910334 y} - APPROVED EY AT BEAM —OTHER METHODS THAT ARE CERTIFIED TO MEET o00 •: THE REQUIRED DESIGN LOAD OF 3150# MAY BE USED. 2. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS 'O '• STATE OF .: WHERE THE ANCHORING SYSTEM REQUIRES THE USE %�O•'•.,/ P '�J�'.` OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CLIP). FERAL MMUFACTURED HOh1E CONSTRUCTIONMD ME D AND �E F1ED OTHERS NOV 2 4 1998 JACOBSEN HOMES NOTICE ' THESE SPECIFICATIONS AND DRAIRNCS ARE M ESF"DRAANc TRIALS OF JAAL cBEN wu�ACTUN DRATYN BY: M.T. DATE 11-18-98 ��. ���: B MILE' MISC. TIE —DOWN \� P.O. BOX 368 INC. SUCH YATEM S ARE PROVDED TO THE DRABINC NUMBER: SAFETY HARBOR, 'FLORIDA 34695 KOMT FOR SPECFIC PURPOSES ARD YUST BE PHONE (813) 726-1138 KEPT R:aanE WI MD SECKI M O➢ERS AD-TD-0050 45 r ADDENDUM �g�s NORMAL TIE -DOWN SPACING TABLES ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III l�yo v FLOOR WIDTH NN. CITY. EA END OF EA SECTION ANCHOR ANGLE MIN. a VIN. CITY. EA SEC OF ESL sEnorH ANCHOR ANGLE uul e 36-8' 3 40 3 25 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX WIND ZO'4E II WIND ZONE III FLOOR WIDTH EAVE OVERHANG SPACING DSL. HEAD LOAD ANXR ANGLE SPACING D LOAD HEAD ANCHOR ANGLE 30,-8' 6' 6'-9' 3150# 41-46 5-5' 31501 44-49 LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III t` U ^oa FLOOR WIDTH UK QTY. EA. END OF EA sEcnoN ANCHOR ANGLE MIN. a YIN. QTL EA. DO OF ESL sEcnav ANCHOR ANGLE uIN. e 364 4 42 4 25 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX WIND ZONE n WIND ZONE III FLOOR WIDTH EAVE OVERHANG SPACING DBL HEADHEAD LOAD ANCHOR ANGLE SPACING D LOAD ANCHOR ANGLE 30'-8' 6' 4'-6' 3150146-50 4'-0' 31501 49-52 VANDZONE III (110 MPH) 20 PSF ROOF 10 PSF D.L. REF. CALM G �� - �4. �1- %i• ,,\111111T1T11J,,, NOTES: I. SEE FULL ADDENDUM FOR ADDITIONAL REQUIREMENTS 2. SEE AD-7D-0071 FOR MAXIMUM PIER HEIGHTS REQUIRED FOR THE LOADS TABULATED ABOVE ElItT AWA0, G\ NO R�t`O ` i� 910334 moo DAPIA APPROVAL, `,, APPROVED BY �T.4pTE OF ' c� INC. ■ „ JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTIC TIHEsE SKanCAIIONS AND WA11NCS ARE ORIGINAL PROPRIETARY. AHD CQilpEN11AL NMER1ALS OF JAt0Dgr1 YAHUFACTLn C HNC SUCH YATEMALS ARE PROVIDED 10 THE RCMENT FOR SPECFE RUMS No wm 5L nPI C*ff 0D IA AHD SEan rROM ODM AWN BY: M.T. DATE: 2-8-99 REV. LETTER: DRAN7NC TITLE: NORM. SPACING TABLES CRANING NUMBER AD-TD-0070 46 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE —DOWN SPACINGS ■µ MA n W-wJv JFZU ►u w-w-wiv inxt nx AUiu-WIU IF&t nx ALP-W-MV IM11 nX AU-IU-WO THE MAX FIGURE 10.0 SEE FIGURE 2.0 FOR ALTERNATE M—DOWN IMOD TYPICAL CROSS SECTION SHOVING TIEDOWNS FLOW7 / .—CMOs s SEE NOTE 5 FOR uAXo>ruT INDGTIT N IY.1I1{A AIKTE ANm ANGiE SE[ AN= WAD WINNONE III o (,mil FIGURE 10.1 (110 MPH) SEE FIGURE 50 FOR ALTERNATE TIE -DOWN METHOD 20 PSF ROOF 10 PSF D.L REF. CALCS c w4 NOTES: tJTQa+ElQ1rPJi9YACE••., DAPIA APPROVAL. 1. SEE AD-TD-0070 FOR SPACING TABLES. Q NO. �� •'•, '% 2. SEE AD-TD-0070 FOR OUANITY OF LONGITUDIAL TIE -DORM STRAPS REOUIRED. 910334 = APPROVED BY 3. SEE OTHER DETAILS FOR BLOCKING (PIER) QUANTITY AND OTHER REOUREMQITS ON 4. SEE FULL ADDENDUM FOR ADDITIONAL REOUfREMENTS. ;.•o •. STATE OF : •� 5. ZONE 2/EXPOSURE V. 56' MAXIMUM HEIGHT t'pti•'••,/ P •C��C INC. ZONE 2/EXPOSIK V- 40' MAXIMUM HEIGHT ����, ••ry�l� �•(�� `` "%,�u,�,y o ZONE 3/EXI'OSURE V: 56' MAXIMUM HEIGHT. �4 F s[. • • • . ` ` t� caumuaia+uos nsramwos ZONE SAVOSURE V.- 40' MAXIMUM HEIGHT i� AM DR JACOBSEN HOMES NXNS AM TN°TTORA DATE REV LETTER: . 71FESE SPECi7CATA NfS ARE M.T. 3-1-99 ORMAE. PROPWARY. AND CONFDEN7UL DRAWING ITM- FIGURES 10.0 AND 10.1 HomimpHP.O. BOX 366 MATMALS OF JACOBSEN MANUFACiu = INC. SUCH MATUMS ARE MWED TO 71E SAFETY HARBOR, FLORIDA 34695 PEOPIM FUR SPECFlC PURPOSES AND MUST BE DRAWING NUMBER: PHONE (727) 726-1138 Tarr CONF7oOM AND SWET FROM o7NEIM AD—TD-0071 47 ADDENDUM NORMAL TIE —DOWN S PACING TABLES ZONE II & III/EXP. C & D i LONGITUDINAL TIE —DOWN SPACING TABLE (+� MIN, WIND ZONE U WIND ZONE III to v FLOOR WIDTH MR OTY. EIL END OF Ek SECTION ANCHOR ANGLE UK W DTI EA. END OF ESL SECTIONwN. oN ANCHOR ANGLE a e 154 3 45 3 35 VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III FLOOR %lDTH EAVE OVERHANG SPACING L' D LOAD ANCHOR ME SPACING ffA D�" LOAD AD ANCHOR ANGLE 154 6' EACH SIDE 6'-10' 31501 40-46 5'-6' 31501 42-47 LONGITUDINAL TIE —DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III C� ^ O FLOOR WIDTH UIN. CITY. EA. END OF EA. SECTION ANCHOR ANGLE MIN. B UK OtY. EA DO OF EA. SECTION ANCHOR ANGLE LON. 9 15'-4' 3 30 4 35 a VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX WIND Z(XJE U WIND ZONE III FLOOR WIDTH EAVE OVERHANG SPACING DSL H AD LOAD ANCHOR AN SPACING D HEAD LOAD LOAD ANCHOR ANGLE AN 15'-4' 6' EACH SIDE 4'-6' 3150j 42-50 4'-0' 3150# 44-50 WINDZONE III (110 MPH) 20 PSF ROOF 10 PSF D.L REF. CALCS. C w d _ • GI - 172 TTTuurlr NOTES: 1. SEE FULL ADDENDUM FOR ADDITIONAL REQUIREMENTS.•O!! 2. SEE AD-TD-0073 FOR MAXILVUM PIER HEIGHTS REQUIRED FOR THE LOADS TABULATED ABOVE. 3. MAX EAVE OVERHANG REFERS TO OVERHANG AT SIDEWALL NOT FRONT OR REAR. 4. 4. ABOVE TABLES APPLY TO 184' FLOOR WIDTHS WITH 95 1/2' I -BEAM SPACING, 96' MAXIMUM SIDEWALL HEIGHT AND 6' MAXIMUM SIDE OVERHANG (6' OVERHANG MAX EACH SIDE OF UNIT). ENo`r, Q ov �F .' fV ••'• ''�. Q S 910334ON '. • � -o •. STATE OP cc, ��'•. P • 4 '��� • , ��� , S • ' DAPIA APPROVAL,Mm 0. APPROVED BY ^ f rf! NC. iarlmaAwtTitwanot Muni JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTI • rrrl THESE SPEWCATIONS AND DRAx41CS ARE DRIONAL PRDPPoETARY, AND COI3IDENDAL ISLIDS A RIALSJACOARE NANUFAGTLIRINc INC. SUCN MATERIALS ARE FRONDED TO THE REC51EW FOR SPECtIC PURPOSES AND UUSF BE AFPT CCNnDEHnAL AND SE00 FROU OHM I! BY: M.T. DATE: 2-8-99 REV. LETTER: DRAWING TITLE: NORM. SPACING TABLES DRAMNG NUMBER: AD-TD-0072 48 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS MAIL PER AD-TO-0012 TABLE PER AD-TD-0012 TAaE PER 0-TD-0012 TABLE PER AD-TD-0012 TABLE - PER AD-ID-OD12 TA<iE YAK TYPICAL CROSS SECTION SHOWING JIEDOWNS FIGURE 10.2 SEE FIGURE Z.0 FOR ALTERNATE T[E-DOVN YE(FfOD 1s SEE ROTE 5 FOR MA)UNY HMT N CLE IT IN SIX FIGURE 10.3 SET ANCHOHOME ) R HEAD WINDZUNE III OF ( 110 MPH SEE FIGURE TO FOR ALTERNATE TIE -DOWN MEE80D 20 PSF ROOF 10 PSF D.L. REF. CALLS _ Gf 2, G'I 2 • ib . a�77tunrrrra,�, NOT ES• ENK� 7apP ..,.. �. �iDAM APPROVA' i 1. SEE AD-10-0072 FOR SPACING TABLES AND NOTES. ` �G\No qF� 1. �: APPROVED BY 2. SEE AD-TD-0072 FOR QUANITY OF LONGITUDIAL TIE -DOWN STRAPS REOUM. 910334 3. SEE OTHER DETAILS FOR BLOCKING (PIER) QUANTITY AND OTHER REQUIREMENTS T-N 4. SEE FULL ADDENDUM FOR ADDITIONAL REQLAREMENTS. CF :4c 5. ZONE 2/ MAE 'C: 56" MAXIMUM HEIGHT -Q� S17ATEINC. ZONE 2/E�OSURE V. 56- MA)OMUM HEIGHT ��p�... / P' � ' FEGFIMLYNIIRCIU®NOIE I�V. ZONE 3/E70'OSURE 'C: 56' MIWMUM HEIGHT ZONE 3/0FOSURE 'D': 56- MAXIMUM HEIGHT • �f' �� i � JACOBSEN HOMES THESE SPECF1cATIM D DRa ARE WO"Y. M.T. DATE 3-1-99 REV. LETTER ORIMIAt. PROPRIETARY. AND MF10ErrIIAL DRAWING TITLE: '-m P.O. BOX 368 MAIERIALS OF WMBSEN MANOFACMING FIGURES 10.2 AND .10.3 kJC: RICH MATERIALS ARE PROVIDED TO 7HE SAFETY HARBOR, FLORIDA 34695 RECFtEIIT FOR SPEM MWOM AID MUST BE DRAB NUMBER PHONE (727) 726-1138 IV7 CON OMM MO SEOM R7M OMM AD—TD-0073 49 ADDENDUM �g�s OFFSET TABLES ZONIT E II & III/EXP.PCCING & D 1 LONGITUDINAL TIE -DOWN SPACING TABLE (+� MIN. WIND ZONE II WIND ZONE M 19N un ACHOR �1 FLOOR WIDTH t OY. EA END OF MOLE ANGLE � END OF NGLE ANGLE EA SECTION WL 0 EA SECTION LOLL 0 12'-0' 3 47' 3 61' 13'-4' 2 54' 3 41' 154 2 54' 3 41' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX WIND ZONE 0 WIND ZONE III SPAM DBI- WA Low MOO ANGLE SPACING OBLWA LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 12' 5'-0' 31501 40' C-0' 3150/ 39' 13'4 12' 5'-0' 31501 41' 4'-0' 30001 40' 154' 12' 5'-0' 31501 43' 4'-0' 30001 42' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE 01 MN. QTY. ANCHOR MAR. QTY. ANCHOR FLOOR Y WIDTH EA END OF ANGLE EA END OF ANGLE EA SECTION MIN. 0 EA SECTION MIK 0 12'-0' 4 45' 4 60' 13'-4' 3 45' 3 1 60' 15'-4' 3 45' 3 60' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. VM ZONE I WIND ZONE 01 SPAM � MON ANGLE SPAM � ANCIN ANGLE Y FLOOR EAVE OVERHANG 12'-0' 12' 4'-0' 31501 40' 3'-0' 30001 38' 13'-4' 12' 4'-0' 30651 41' 3'-0' 30001 39' 15-4' 12' 4'-0' 30651 43' 3'-0' 30001 41- NOTES: I-6 l - C4 LZ5, C- SL - /16 O1- l6 • 12- F� ENGINEER A PPjtQlI § 81 •t.', REF. CALCs G1-- 0 - I Q r 7 �.. �'FO r''e• 1. OFFSET SECTION PATH THE MARRIAGE U K WALL EXTENDING BEYOND THE ENDWALL OF THE ADJACENT SECTION MUST BE TIED DOWN AT THE MARRIAGE LINE IN ACCORDANCE ��• • •'•q�, R� D BY N'W! ♦��, �fi1i OY R': WITH THE TABLES ABO%E. THE SIDEWALL SIDE AND THE ADJACENT SECTION(S) ARE TO , BE TO DOWN IN ACCORDANCE 1NTH THE NORMAL SPACING TABLES (SEE AD-70-0010 . JUN 1 FOR 12'-0• & IS-4' WOES, AND AD-M-0070 FOR W-4' NDES). 2 AD-1D-0001 FOR REQUIREMENTS. SEE ADDITIONAL INC. 3. SEE AD-To-0081 FOR MA)dMUM PIER HEIGHT REQUIRED FOR THE LOADS TABULATED ABOVE.••........•EDERALMANUFACTU •• ' �J • RED HDNIE JACOBSEN HOMES �NOn'�' D*m sPEcr amm m DRA utioi4�'`` 1.T. DATE' 6-8-04 ' taTLR DRAWING TITLE. . OFFSET SPACING TABLES A P.O. Box 36e . PRWWAY, AM 111ERM OF W.20 MATQI" AI E w DRAWING NIBIBEf� AD-TD-0080 SAFETY HONE (OR,)FLORID;38 95 Wn f�1CM SNUMM 50 ADDENDUM OFFSET UNIT TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SHOWING IE-DOWN SPACINGS FIGURE 11.0 SE MORE 4.0 Nit ALT>;RNATB TIC —DOWN Y6ffHOD TYP. CROSS SECTION(S) SHOWING TIEDOWNS SEE NOTE 5 FOR MAI m mw (TARES al AD-m-m DUE APPLY M TIM STAIOARD RILTI­-WE SEC➢OHS W 1FE UFIT -SEE WIE 1. AD-M-M) TV FLOOR STSIEII--7 ID t— A A —! I— Him MQE �6��4 c� t6G �� FIGURE 11.1 �- u SBE FtSm &0 FOR AL'tBM= TI —DOWN sm NOTES: 1. SEE AD-TD-M FOR SPACING TABLES (OFFSET SECT N ONLYQ 2. SEE AD-TD-OOBO FOR QUANNTY OF LONGITUD1AL TIE -DOWN STRAPS REQUIRED. (OFFSET SECTION ONLY) 3. SEE OM DETAILS FOR BLO0 NHG (PER) OUANDTY AND OM REQUIREMENTS. 4. SEE AD-TO-0001 FOR ADDITIONAL REQUN WENTS. 5. ZONE- 2Jrf0m1AE V: 48• MAlIM1UM HEIGHT TIP. ANaIaR Al1OE-1 R FIGURE 11.2 fj FOR 1IMMTB TIC —DOWN MCIHOD 1; DAPIA APPROVAL :�� `;` •-afiFi�••.'�t�` 'dam PPROVED BY M ZONE 2AIPOM V: 40' MAXNUM HEIGHT-36• FOR 12'-D• WIDE UNITS '.� (� �••..h ZONE 3/EIlPOSURE V: 4r MAAMUM HEIGHT .��iS� .• R ZONE 3/E�OSIIRE V. 40' MAWA HEIGHT jut4 I I 2mk INC. fACTURED HOME AND SAFETY STANDARDS JACOBSEN HOMES mnca 'r' r�o TESL WEanUTM MV O AIM ARE ... ` M.T. DATE. 6-8-04 REV. LETTER: P.O. BOX 3s8 MGM. plimmmy. AM oNRMTK MAIENAS OF °ACOM YAIMACII IM DRAWING TITHE: FIG. 11.0, 11.1 & 11.2 V SARTY HARBOR, FLORIDA 34695 &THIIACS wx PROm TO TIE FMCaI YA FEt>PNNT FOR NEW ROM AID MIST BE DRAWING NUMBER: PHONE (727) 726-1138 IIFPT aMEMAL AID SECRET MW GUM AD—TD-0081 51 ADDENDUM ALTERNATE* OFFSET UNIT TIE- DOWN SYSTEM I. -OF ,N_ -III I!P WAIL PER 0-1D-0090 TABU I NA>L PQt AD-ID-007D TABLE PER AD-TD-0070 TABLE ff SET SECIIW OF LOT OR AD-TD-COIO TABLE Ot AD-7D-0010 TABLE FIGURE 12.0 SEE FIGURES 11.1 AND 11.2 FOR NOTES: I. SEE AD-ID-0060 FOR SPACING TABLES (OFFSET SECTION ONLY 2. SEE AD-TD-ODRD FOR OUANITY OF LONG17UDIAL TIE-DOTM STRAPS REOUBIED. (OFFSET SECTION ONLY) 3. SEE OTHER DETAILS FOR BLOCKING (PIER) QUANTITY AND OTHER REOUIREMENTS. 4. SEE AO-TO-0001 FOR ADDITIONAL REOUIREMENTS. No. O'•. 910334 y : mea A STA i E O% i PER AD-TD-0070 TAB[ OR AD-W-D010 TABLE - so- SECTION PIA APPROVAL: G7IOFri,;�DSAFEIYSil NOTICE: DRAWBY: DATE: REV. LETTER; JACOBSEN HOMES THESE SOEcaElunoes AND DQAIMNIS ARE R.R. 5-9-01 ORrAAL PROPRIETARY. AND CMDURAL DRAWW TITLE: P.O. BOX 368 MATERIALS OF dACOBSW MANUFACTURING FIG. 12.0 — TME SAFE7Y HARBOR. FLORIDA 34695 A p�� OR y�� �P�S�j p W$7 BE PHONE (727) 726-1138 art coNnamTIAL ASELHEI n= DIM& DRAYANG NUMBER ID AD-TO-0082 52 ADDENDUM GUgEs SPA ING 108" HIGH SMEWALL TIE -DOWN TABLES 1Q 0 ZONE II & HI/EXP. C & LONGIT INAL TIE -DOWN SPACING TABLE c (+� MIN. WINO ZONE II WIND ZONE N FLOOR MN. OTY. AN01 R WK oTY. Alim W1DTH OF A EA. DO OF s sECTIai L Mile EA. SECTION ImQE MEI. e L O� 26'-8' 3 42' 3 53' 30'-8' 3 5T 4 45' VERTICAL TIE -DOWN / FRAME TIE -DOWN I SPACING TABLE MIN. MAX WIND ZONE N WIND ZONE Ill SPAW LDS mam ANml SPA= °�� MOM ANOE MOTH OVERHANG 26'-8' 6' 6'-8' 31501 40' 50' 6-4' 31501. 4U =50' 30'-8' 6' 6'-8' 31501 40'-50' 5'-4' 31501 40'-50' LONGITUbINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE u WIND ZONE In OTT: DAD aF recTm MOM WL oTY. END OF MUR AM FLOOR MOTH IL IN SECTIOtI MIL 9 O 9 FA FA 26'-8' 4 41' 4 57 4 51' 4 70' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE N WIND ZONE M PAW All M ACE SPACH9 HEA �IDADD AWO MM MOIHH OVERHANG 26'-8' 6' 5'-4' 31501 4(-50' 4'-0' 31501 40 -45' 30'-8' 6' S'-4' 31501 40'-50' 4'-0' 31501 40 -45' 1NNDZONE nI (110 MPH) 20 PSF ROOF 10 PSF D.L REF. CALM 054.1 ter 2 3 o�el�j,, otrl . :..'� - DAPIA APPROVAL NOTES• NOTES: ��- �r�`t•'''-�'+' APPROVED BY 1. SEE FULL ADDlX Ml FOR ADDIIHDNAL REOUMMMENTS: Z C) ' No.0045484 u *Oro 2. SEE AD-TD-M FOR MAbLNY PIER NBWS RE01ARED FOR THE LOADS :t TABULATED AB01%E. * ' ` INC ;�� �'/ �RT�•''.y rTF�E� IV- FEDERAL. MANUFACTURED HOME SlALOAROS ; CONSTRUCHON AND SAFEPf P.t, �• JUL 2 r 2 M4 JACOBSEN HOMES NOTICE DRAW UM�rA1d AM DAB NE or M.T. DAIS 07-20-04 REY LEf1Eit TITLE: 108' HIGH SIDEWALL SPACING TABLES P.O. BOX 368 010M. txo MMY NO C&fW X- DRANK MAC W AMMM UffiffAMMO W_ SUCH MAMIMS NE FWAM 10 VE NIMLBM AD-TD—OW3 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOW tat SW flAU8M NO ON BE DRANK Wt caNtmna No smut MOM omm 53 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SNOWING TIE —DOWN SPACINGS TYPICAL CROSS SECTION II SNOWING TIEDOWNs TIE Ilm AN1110t RIM SET ANdIOiHEAD FIGURE 10.0 FIGURE 10.1 REF. TIP. AMm ANHE SSE NOIE 5 FIR VAX" WCHT ro(- ly,, z YMNDZONE III (110 MPH) 20 PSF ROOF 10 PSF D.L NOTES; cnu. `'•,.;ai•• I� vrr n rrrnv.n 1. SEE AD-10-M FOR SPACNC TAEIFS �UG��YIF • • APPROVED BY 2. SEE AD-TD-W FOR QUAFATY OF L NdNDUI X-DOW SWAM KOLO D. N fl J. SEE OTHER OETA/S FOR EILOCMG (PER) QUAM17Y AND OTHER FIEWFO07LEL 4. SEE FM AODEI AI FOR M01I0NAL REOARE31E1ET5 EL 5. ZONE z/EPOSUF E 'e: So MAXIMUM HEICHi y ;� .� Q INC. ZONE 2/E,xPOSIIRfi V. 2r MAMMUM HEIGHT i �`+� � R� Q .� 1 ZONE 3/�OSURE 'C': 3e WAWA HEIGHT INIH i '•• 1 aiaia . ' o� ZONE 3/ExP FIE V. 3r MAXIMUM HEIGHT �iC�rJ' „ ••••-• � \� +e FEDERA MANUFACTUflfO HOME T N + CONSTRUCTION AND SAFEIY STANDAHUS 6. ALL 9PECIFN.ATiO1S ARE BASED ON 2a' ROOF ANGLE MAX. ''� 7 Luuk JACOBSEN HOMES DESE SPEffIGam Me PR,,,� M.T.RE DATE In. L�rLE>� �'� 07-20-04 rlElwlORIGINAL FRwwARY• AND 00*06NUAL, DRANMG Tl=-d. P.O. BOX 3se MATERIALSCF ANCO of MANWAC11°'� FIGURES 10.0 AND 10.1 fIG SM MAIERIMS ARE PRd1�ED 10 x SAFETY HAROOR. FLOMDA 34695 NOW FM 9M F Ff= NO MOT t pRA1� PHONE (727) 726-I IW WT OWWOMM No MW RR[M UMM AD—TD-0084 54 ADDENDUM 108" HIGH SIDEWALL TIE -DOWN SPACING TABLES : ZONE II & III/EXP.. C & D LONGITUDINAL TIE -DOWN- SPACING TABLE WIND ZONE 1 WIND ZONE II t1 FLOOR • Yo+. arr. MDR ix art maraR 1YIDTH � Elm or ANQi EA o+D w WE E,l SECttW 1m1. o Dl s1:CRDl MUL e 23'-4' 2 58' 3 43' 24'-0' 2 62' 3 45' YERTICAI;_ TIE -DOWN : FRAME -TIE-DOWN SPACING- TABLE AIN. MAX WIND ZONE 1 WIND ZONE IJ . . 5r'AONC DBL HEAD LOUD ANDpR AMQI: SPAONC � WAmoat La�o marWlahl FLOOR SAVE OVERHANG . 64' 31501 49' y-4' 3150 f 45' 24'-0' 6' 3150 49' 5'=4' 3150 45' LONGITUDINAL CIE=DOWN SPACING TABLE MIN. WIND ZOME 1 WIND ZONE IR FLOOR MR on ANDiOR lraK DiL ANQfCR WIDTHA E DID Or MuMuA. Qo E a mu O v EA SECiIOi YGL 0 EA SECCB01 VOL A 23'-4' 3 48' 4 43' 14'-0' 3 Sr 4 .45. VERTICAL TIE —DAWN / FRAME TIE —DOWN SPACING TABLE • WN. �� WIND ZONE 1 1NND ZONE II �� o�. A LOAD ANRtOR AMQi SPAanc LOUD ua+cw And,E FLOOR MOTH �EAVE OVERHANG 23'-4' 6' S'-4' 3150 ' 47* 4'-0' 31 43' 24'-0' 6' 5�-4' 31501 41' 4'4' 3150 43' • 108' MAX 9DEWALL HEJCHT N7NDZONE II/IR • (110 MPH) , • 20 PSF ROOF 10 PSF D.L REF. tJILCi ' ,`lija1islyrir��� NOTES: ` ;�'`=Q ��• ! DAPY1 PROV/1L: AP • � 1. SEE it1LL ADOEJtDUY FOR ADOIAOIW. REWI(rFIA►t1S O', . SDK i F: �,4 . �.�'�� G�li APPROVED BY ON Z SEE AD-70-OOBti FMYA7GWMI PIER HMOREOUBtED FOR 1HE LO ti ��. {`'�• �, u 13,2006 TABUiAIED ��.Dec• INC: � Si'.AI c GW �` � :'�� AMIFACIUIED ND1E FEDERAL W CONSINDLTNIN AND SKEfT STANDARDS • �okto�; moo.. JACOBSEN HOMES • NOliCly 2W1 I 111ESE9aE01�11016ANDtIRANTltSARe low Bl: R.R. DAM 11-28-06 REx IETtER: • DRAMeIC All% 108' HIGH SIDEWALL SPApNG TAM � PA eox 38e .. OIIIGNM. !'RWIOLGRG AND R:rFlGEMLx YA7F71WS ti i�DBSFM MAtAN'AC111RDIC nc swi r�eaMs ARE vNDwDm TO ZN[ . SAiETY HARBiOR, FLORIDA 34693 �+oNE (�z�) 729-113e IDL770(� RR Si47fIC 7t16'06ES Am 116E lE gar ao�mocDu.,rm �cr ma aaas DRAIYNC NUMBER: AD—TO-0085 • . 55 ADDENDUM _ TIE -DOWN SYSTEM TIIP,CAL SK ELEVATION . SHOWING TIE —DOWN SPACINGS. FIGURE 10.0' TYPICAL CROSS SECION I SHOP R(G TIEDOWNS Tlp. � + s TV. su ANm r QITIRWI of act AN 0 AKLE CR IIPPRm STABlm MUD D 111111 AWN WR IERIK AL FIGURE 10.1 YAAAN HOGHT 18NDZONE KIM (110 MPH) 20 P5F ROOF 10 PSF D.L. NOTES• I. SEE AD-10-Coss root SPAOW TABLES E�. �` O ^Z �i�%sj ► APPROVAL: BY j;•<:r'�,, APPROVED . Z SEE AD-M-Goes FOR aMan OF lCHanmu IE-DOWN STRAPS REOUM. ON 3. SEE 01HER DETAILS FOR BLOOM (PER) QUANTITY AND OTHER RECINREYENMwoo ` . Cr E 4 ,. SEE FULL ADDEHDW FOR ADanoNu REDUREYENTi ,' ; Dec 23,2006 5, ZDHE 2/DP0AIBE•-E 44' 1101IN HEIWR ZONE 2/EIIPM5 K V. 2r RAMNA1 MW A I N C t ,. • 0� : ZONE 3/EXPOSIX V- M- -MAIIDRAI HEIGHT • •/; 1 . : •n! -)! . FEDERAL KANLWACnIRED HONE STANDARDS ZONE 3jtWOAMIE V. 3r MAX" HELM F, Y .!` : C -• ��• �• c0nsraucnoN AND suer 6. ALL 9?EOIVATIONS ARE BASED ON 2(F ROOF ANGLE MAX AND 106- MAX 90EWALL HE CHT. • •�/ TEFL /�f1.C;�-....• ,f ;14y� tr± JACOBSEN HOMES NOTICE �Ait DIM WCOMUMM1 AK 9�Vt R.R. DATE: 11-28-06 fEV.LE��Eit DRAWL OILS: - ORCHAL MOVE=. AND COfLE1111A11 \I H P.C. BOX 360 MAVA "s OF ACO�D"'A"'�ACU01C 1NC AIM MAIENALS ATE MWAM TO THE FIGURES 10.0 AND 10.1 SAFETY HARBOR. FLORIDA 31693 PHONE (7Z» 726-1135 SwF 1M swrc Firm Am HIM K Nv1 CcNI IAL AM Wo FROM onus DRAIANC NUMBER AD-TD— 0086 =N m � A 56 ADDENDUM SHEARWALL TIE-DAWN/PIER REQUIREMENTS Err. 3A tE►icm+ [ff. 5nr LD1 . , tn. s//r Cc" w It MY It 6� 1 1 - 1 1 TAo PER SHEA"ALLS 1 i Tip PIER 3 AAWALLS (ALL STVAtM) 1 1 (ALL N1UAA0`Rj t cc -Do" Rflalli3D ii-OOrRt3 pEAuom 4. 1 Tr 5M NOTE 1 at WE 1 5m How 1 sm NOTE 1 %a NOTES 2 Arlo J. zN A SEEmmE3 2 Ate 3. Q ►a nQb mm no r£R M3rQ pa Ism'o THs LocAral IRS LDCATM 1FH t9gAT" ms =AnOH FIGURE 8, 0 FIGURE 8.1 THE DETAIL ABOVE IS SHOWN WITH A TWO PIER SHEARWALL CONFIGURATION, HOKYER, THIS DETAIL APPLIES TO All SHEARWALL CONFIGURATIONS, ALL ZONES. -AND ALL °LF VALUES. Dom AFY Ws--- 1. w-caws waxi n"W= MAX Tt-ww mww MAT er LOaTo lx �` PPROVED BY UM Or TNG AcW Woo" ASM Obi F== AT 001� tRa+4 A*pis TN eE PAO MR AN tI.RYATE LOAD 1F mw D s(" LOAD] ....... {g[ AO-�C001 Im-oxgAt MOTO] FM (1m Gf Ct0(i0 Il�3f�t 1KSTld11rA�L) � •_ �Cs�'�1' C-• F� :� '�. { EB 1 0 2W0 L NEILL A M AT Gel DO Cr M 20ft Il J= rrtR ro(C Aflo1C Em Rrqjwm AT Elm Eta w "Sis Itt" ns or X-ova, �TM+w kcaaaycrcTs) i 910334 1 � t�F INC X V 01 51[&"ft LS LOCAM A "C A W KAW M lWfT a -YEm" no W.0-W . t ?&WW 3Tr n Ot FOS AAA¢ R[QMC (KL:1W%lL oW=PAUWM Au UM � � F ERAL MANUFACTURED HONIE �� hOALL (Wo8TA►•F �,`c� C NSTRUC710NANDSAFENSTANDAROS dACOBSEN HOMES T�aTict;.� ; `''R.R. 02--pt-Oo wit artoriupva No osuoxa. reonaErA 4 on •. P.p. eox Jaa MAW"; of yKgaxH q�Vo1� �' R7 � S/W TIE/PIER REQ. w- 9M skimMA Asti — B WET r HAROM FLQRIOA 3093 1e4>t�txi fat 9snrC R+woxs w r„ It pW1w++G KA(s .. . PHONE (777) 720-1138 Mr oarrvcx 4 w4 ao�,t1 9 offa c AO-TO-100 57 ADDENDUM DOUBLE SHEARWALL CONFIGURATION SINGLE —SECTION TIE —DOWNS / CfDLL40 MAY BE FLAT OR SLOPED NOTES: 7-/7114 r. GROUND ANCHORS TO BE RATED FOR AN ULTWATE LOAD OF 47251 13150 DESIG4 LOAD] (SEE AD-1D-001 ITD-CENLRAL ROTES] FOR NOTES ON fROUM AW>IOR INSTALLATIOtL) 2. KSTA71 A PER AT EACH END OF THE SNEARWALL JOISTS (PER THE ABOVE DEWLS). 3. %WLN S-EARWALL IS LOWED ABOVE A SOLID HEADER (FULL HEIGHT CROSS-UEN9FP.) NO TIE-M" STRAPS. OR PIERS ARE REOLARED (ALL SHEARWALL CONFICURATIN.tS ALL ZONES AND ALL EPO_RM). 4. TIE-DOWv STRAP REQUIRED AT EACH END OF JOISTS, ALL OB_ r;,/W CONFIOJRATIONS. 5. CEILWC 54OW`4 FLAT -OPT, CATHEDRAL OR SLOPED CEAJNC MAY BE USED. i 6. FULL WIDTH SHEARWALhS ARE SHOWN IN THE DETAIL•ABOVE. HOWEVER, ANY LENGTH OR CONFIGURATION SHEARWALL MAY BE USED. END VIEW 350 PLF MAWUM SHEARWALL DES'GY VALUE (PER WALL) 1 1/4' X .035' r-E-,^,OWN STRAP COKnVUCJS ARCJSD JOIS75. .. � r I .Z E�TG (Pf1ROVAUQz NOTICE. DRAWN JACOBSEN HOMES .nWSE SPEOrICATIONSAND DRAWNGS ARE CRMAIAL, PROPRILTA.RY, A. -AD CODFID£NT1AL DRAW j� P.O. BOX 368 MAIER.A1S OF JACOBSEN NANIIFACTURNG THE SAFETY HARBOR, FLORIDA 34695 OMI FOR � PURPOSES OS w TO EE DRAW:! PHONE (813) 126-1138 KEPT CONRDEnAL NO SEOREr ntD4 onas. DE VIEW X .OW TIE -DOWN STRAP JOUS ARCAW MTS. DAPIA APPROVAL• APPROVcD BY I V_' 0 Oori N' RDEPALwxnlF1z lve£: lul R.R - 2-6-96 TITLE: DBL. S/W CONFIG. TIE -DOWN NUMBER` AD-7D-0110 58 CEILING MAY BE FLAT OR DOUBLE SHEARWALL CONFIGURATION TRIPLE & MULTI SECTIONS SIDE VIEW SIDE VIEW (MARRIAGE WALL APPLICATION) (SIOEWALL APPLICATION) 350 PLF MAXIMUM SHEARWALL DESIGN VALUE (PER WALL) 1 1/4" X .035' TIE -DOWN STRAP CONTINUOUS AROUND JOISTS. 350 PLF MAXIMUM SHEARWALL DESIGN VALUE (PER WALL) 1 1/4' X .035' TIE -DOWN STRAP CONTINUOUS AROUND JOISTS. BN IS A TRIPLE WIDE RAFTER, ) APPLICABLE TO STANDARD BLE WIDE TRUSSES. qD VIEW X .OW TIE -DOWN STRAP UOUS AROUND JOISTS. NOTE: ALSO APPLICABLE TO 'SUP SIDE' MARRIAGE WALLS WHEN AT LEAST 2 STANDARD VERTICAL TIES ARE INSTALLED, (1 EACH SIDE ADJACENT TO SHEARWALL LOCATION) F TO' �/��j•����: V\ �6: 35' /i / /i NOTES: ENGINEER APPROVAL: DAPIA APPROVAL: I. GROUND ANCHORS TO BE RAID) FOR AN ULTIMATE LOAD OF 47251 [3150 DESIGN LOAD] (SEE AD-TD-DDOI [TD-GENERAL NOTES] FOR NOTES ON GROUND ANCHOR INSTALLATION.) 2. INSTALL A PER AT EACH DO OF THE SHEARWALL JOISTS (PER THE ABOVE DETAILS). pp n ayPPRO 4`' ED By 3. WHEN SHEARWALL IS LOCATED ABOVE A SOLID HEADER (FULL HEIGHT CROSS -MEMBER) NO STRAPSOR PIERS ARE REQUIRED (ALL SHEARWALL CONFIGURATIONS. ALL ZONES AIID ALL � � 4. TIE-DO'ATT STRAP REOUIRED AT EACH END OF JOISTS, ALL DBL S/W CONFIGURATIONS John C. Doe en, P.E. 5. CEILING SHOWN CATHEDRAL OR SLOPED, FLAT CEILING MAY BE USED. ],5133 C. R. ZZ ARE SHOWN W THE DETAIL ABOVE, HOWEVER, ANY LENGTH 6. FULL WIDTH SHOWN ALLSSHEARWALL OR COF:FlCURA110N SHEARWALL MAY BE USED. Goshen, IN 46526 7. THIS DETNL MAY APPLY TO TRIPLE AND/OR DOUBLE WIDE SECTIONS DOD ,I❑NC. HEID JACOBSEN HOMES BOx 368 NOTICE: THESE SPECIFICAna+S AND DRAri1NO5 ARE ORIGINAL. PROPRIETARY. AND CONFIDENTIAL MATERIALS OF JACOBSEN MANUFACTLIRINC SUCH MATEMU ARE PROVIDED TO THE DRAWN BY: R.R. DATE: 4-09-96 REV. LETTER: A DRAWINGE:P.O. �' S/W CONfIG. TIE —DOWN SAFETY FLORIDA261D11384695 �PURPOSTS� EtuST BE APT DRAYANG NUMBER: 0 ER(813) COWf L SEaza opgn AD—TD--0111 59 PORCH ANCHORING DOUBLE HEADED 3,11, NOTES: 1. SEE SET-UP MANUAL AND ADDENDUM FOR APPLICABLE BLOCKING REF.t,CALIS.` ENd AP�RQVA�:; . " '1 A. xONS DRAW JACOBSEN HOMES THESE SPECEi1CAlIDf15 AND ORAMNGS ARE AND HE ORONAI, PROPRIETARY, AND COHFrDENTM DRAIMN „ P.O. BOX 368 MATERIALS CF JACMSEN MMiFACWRW TO SAFETY HARBOR, FLORIDA 34695 Huai Fpq SEOM AND ff DRAWN PRONE {727) 726-1138 KEPT CONMOMAL AND Sf�T ERIM OREOiS. X .035" T(E-DOWN STRAP 10US AROUND STRAP 13LOCKS. WINOZONE III EXPOSURE 1; (110 MPH) 20 PSF ROOF 10 PSF D.L C wfq - 109 ,G f - ►09,V 7 OAMA APPROVAL• PPROVEQ BY INC. MANUFACTURED HOME CTION AND SAFETY STANDARDS M.T. 1 12-13-03 PORCH ANCHORING AD-TD-0112 fiia'A141123 60 ADDENDUM ALTERNATE VERTICAL TIE -DOWN APPLICATION APPROVED VERTICAL 1IE-0 (FACTORY INSTALLED) FLOOR DIAGONAL FRAME TIE ANCHORING EQUIPMENT CAPABLE OF RESISTING THE WORKING LOAD REQUIRED ON THE TIE -DOWN SPACING TABLES (SET_ OTHER DETAILS FOR TABLES) SEE OTHER DETAILS FOR ANCHOR ANGLE. NOTES: 2 3. CRIMP SEAL (3150# WORKING LOAD) LTS x X 6 L� N W W VER i ICAL TIE -DOWN � TYPE 1, FINISH B, w GRADE 1 STEEL STRAPPING o 1 1/4' WIDE k 0.035' IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION 03953-91. STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. ALL VERTICAL TIE —DOWN STRAPS, DIAGONAL FRAME TIE —DOWN STRAPS AND ANCHORING EQUIPMENT SUPPL BY AND INSTALLED BY OTHERS— ON SITE. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR— ATION. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL. STRAPS OR CABLES (SEE RADIUS CLIP). JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR. FLORIDA 34595 PHONE (813) 726-1138 OWN ANCHOR BRACKET RADIUS CUP MUST BE INSTALLED ON ALL TIE —DOWN ANCHOR BRACKETS. (INSTALLER TO FABRICATE RADIUS CUP BY PLACING A STRAIGHT 3' LENGTH OF 1 1/4- X 0.035' TIE —DOWN STRAP MATERIAL IN ANCHOR SLOT AND BENDING TO FORM THE CONFIGURATION SHOWN.) RADIUS CUP MUST BE INSTALLED TO PROTECT THE TIE —DOWN STRAP FROM THE BRACKET EDGES. INSTALL THE TIE —DOWN STRAP THROUGH THE SLOT IN THE BRACKET ' T P ' THE RADIUS CLIP. ``Itj1uIII lall,"ll ,•`a`N C. Do F''% C1` !tt•A{eROva�;i0. c0 • ENE8703571_ per•,•%vl.✓ /'��...•��: E, I A ONAL EN, ANCHOR BRA�I(�iLAND ,TIE`DOriN DEVICES ARE CERTIFIED BY OTHERS NOTIM naAMM RY.. 1145E SPEanCADONS AND DRAMNGS ARE CLONAL PROPFAETARY, AND 0CNFWTIAL t1ATMALS OF JAC08XN YAl"ACTANG W_ 511Qi YANYMS ARE PROVIDED TO THE REW04 FOR !PECFX PUMP AND LLIST BE WT CoHrM0AL NO SE01ET EROY OTTERS C.L.Y PROVED BY JM 1 5 ON 14 INC. FEDERAL WMiKIUi®NDI[ CO'6iRUDIRI AID SA!ETT SLAk= 5-31-95 ALT. TIE -DOWN APPL. AD-TD-0200 MY. LETTER A 61 ADDENDUM ALTERNATE VERTICAL TIE -DOWN APPLICATION APPROVED VERTICAL TIE=DOWN ANCHOR STRAP (FACTORY INSTALLED) FLOOR F— IF FACTORY INSTALLED STRAP IS NOT LONG ENOUGH, - IT MAY BE LENGTHENED BY USING A CRIMP SEAL WITH A WORKING LOAD OF 3150 POUNDS. A0 g� y IF NEEDED, USE VERTICAL TIE -DOWN TYPE 1, FINISH B. p /r GRADE 1 STEEL STRAPPING �y 1 1/4- WIDE k 0.035- �l f IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS DIAGONAL FRAME TIE CONFORMING WITH ASTM STANDARD 0 SPECIFICATION D3953-91. 0 STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL. AND SEALS. II III Illr'III ANCHORING EQUIPMENT —III III -I I I -I i CAPABLE OF RESISTINGI- THE WORKING LOAD REQUIRED ON THE —III -I TIE -DOWN SPACING _ TABLES (SEE OTHER I III —I I (— DETAILS FOR TABLES) _ SEE OTHER DETAILS I i-III—III-I FOR ANCHOR ANGLE. NOTES: ` = �GE� c DAPIA APPROVAL 1. ANY ADDITIONAL VERTICAL TIE -DOWN STRAPS, DIAGONAL ' •;R NO. ,0 FRAME TIE -DOWN STRAPS AND ANCHORING EOUIPMENT 910334 -_ SUPPLIED BY AND INSTALLED BY OTHERS- ON SITE. = APPROVED BY 2 ANCHORING VEARESISTANCETO EQUIPMENTEXPOSED WEATHTO ER SHALLATHERING R DETER OR- � �'•• STATE C00or REVISED ON 14 ATION. �' �� ' 01 10R3J96 3 PROTECTION SHALL BE PROVIDED AT SHARP CORNERS OFERE THE ANCHORING SYSTEM EXTERNAL STRAPS OR CABLES E(SEE ERADIUS S THE UCLIP). '''wMl �``` F�� TXW upT INC. ME11:1 JACOBSEN HOMES THESE smanCATIONS AND DRAmRGS ARE SAFEWSEVaUM DRaxN�Y: R. R. DATE' 30-05-96 �W' �///1���rER: OPIONAL. PROPRIETARY, AND COITIDENML DRAWING TITLE: / \ IL MATERIALS OF JACOBSEN MWIUFACMNC ElElP.O. BOX 368 INC. SUCH MATERKS ARE PRDNDID To THE ALT. TIE —DOWN APPL. SAFETY HARBOR, FLORIDA 34695 REOPENT TOR SPEOTIC PiA7 = Mm u09 RE DRAMNG NUMBER PHONE (813) 726-1138 IVT CDNRDENIUL AND HOST rRou onm AD-TD-0210 62 ADDENDUM COLUMN TIE- DOWN ' APPLICATION 'A' COLUUN 'B' (COLUMN SEE TABLE FOR MAXIMUM SPAN FOR COLUMNS 'A' OR 'B' 'C' COLUMN '0' /COLUMN SEE TABLE FOR MAXIMUM SPAN FOR COLUMNS 'C' OR b'_ I r SEE TABLE FOR SPAN COL 'E' SEE TABLE FOR MAX SPAN FOR COL 'C' COLUMN E' 'r COLIAJN 'G' — �COLUMN SEE TABLE FOR MAXIMUM SPAN'FOR COLUMN r MAXIMUM ALLOWABLE SPAN TYPE OF ANCHORING REO'D (SEE AD-TD-0251. COLUMNS 'A', V. 'D' OR 'E' COLUMNS 'S' OR 'G' COLUMN T' AD-7D-0252 AND ZONE 2 ZONE 3 ZONE 2 ZONE 3 ZONE 2 ZONE 3 AD-TD-0253) SEE NOTE 1 EXP. 'C EXP. V ENP. 'C' EXP. 'D' EXP. 'C' EXP. V EXP. 'C' EXP. V OP. 'C' M. 'D' EXP. 'C' EXP. '0' 2 - 31501 ANCHORS 4Y-O' 29'-6' 33'-9' 23'-7' 43'-0' 29'-6' 33'-9' ' 23'-7' 4Y-O' 29'-6' 33'-9' 2Y-7' 1 - 31501 ANCHOR 21'-6' 14'-9' 16'-10' 11'-10' 21'-6' 14'-9' 16'-10' 11'-10' 21'-6' 14'-9' 16'-10' 11'-10' 1 - 40001 ANCHOR 27'-3' 18'-9' 21'-5' 1 15'-0- 27'-3' 18'-9' 21'-5' 15'-0' 27'-3' 18'-9' 21'-5- 15'-O' NOTES: ENGINEER APPROVAL: DAPIA APPROVAL' APPROVED BYP, 1. SEE AD—TD-0251. AD—TD-0252 AND AD—TD-0253 FOR SPECIFIC INFO. ON ANCHORS. 0151 2. SEE AD—TD-0001 FOR ADDITIONAL NOTES ON ANCHOR 'NA INSTALLATION. John C. Doeden, FEMf^M.sA0LMlCW INC, 15133 C. R. 22 t�„o:AFE„r�+aADe Goshen, IN 46526 JACOBSEN HOMES NOTICE THESE SPEC01CATIONS AND DRAMNGS ARE DRAWN BY: C.L.Y. DATE: 5-31-95 REV. LETTER: MONAL. PROPMETARY. AND MWIDENTA MATERIALS OF JACOBSEN MANUFACTLRING DRAWING TITLE -'A COL TIE APPL. LaP.O. BOX 368 . LNG M MATERIAS ARE PRONDED TO THE —DOWN DRAWING NUMBER AD—TO-0250 SAFETY HARBOR FLORIDA 3*95 PHONE <813) 726-1138 RECRE NT FOR V[CnC NRP0.9:S NO "I BE IVT 0XID XPAt AID SEM FROW OTHERS 63 ADDENDUM COLUMN TIE -DOWN APPLICATION FLOOR ANCHORING EQUIPMENT CAPABLE OF RESISTING THE WORKING LOAD OF 3150 / MIN. ® ANGLE SHOWN. 3Y ANGLE 1=1 I I i t I I- ANCHORS INSTALLED 24' APART COLUMN STRAPS SEPERATE GROUND NOTES: 1. ALL ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS— ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR— ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES. MARRIAGE LINE OF MULTI -WIDE ATTACHED ANCHORS VERTICAL TIE -DOWN TYPE 1. FINISH B. GRADE 1 STEEL STRAPPING 1 1/4- WIDE ✓k 0.035- IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL, AND SEALS. 35' ANGLE TO TWO (3t5O# EA.) No. ENE8703571 'i A F F =... `v`ED 8Y A- -NI,� il JUN 1 5 Fmp^~AINC �� CaaTI XDMAWLVMWAW" JACOBSEN HOMES rtQI1cE A""' TNl:se srtanewnaHs A,a DxAr,Hcs Axe: CRONAL IMtOMVMY. AND CCNnmNT1AL 'dhA1vN BY: C.L.Y. DATE 5-31-95 REV. LETTER: n DRAWING TITLE P.O. BOX 368 m HATkRA S Or JAC08XN YMAAFACVMG COLO TIE —DOWN APPL. SAFETY HARBOR. FLORIDA U695 THE. pT�T rCR 7x PJMM NO ARE PRMMiM 6E /Hl DRAWING NUMBER: PHONE (813) 726-1138 I®T CCNMnk MO gav nmm o11FRi AD—TO-0251 64 ADDENDUM COLUMN TIE -DOWN APPLICATION FLOOR ANCHORING EQUIPMENT CAPABLE OF RESISTING THE WORKING LOAD OF 3150 / MIN. COLUMN STRAPS SINGLE GROUND NOTES: 1. ALL ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS- ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES. H. MARRIAGE LINE OF MULTI-'MDE FLOOR VERTICAL ME -DOWN TYPE 1. FINISH B. GRADE 1 STEEL STRAPPING 1 1/4• WIDE & 0.035' IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91, STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. ATTACHED TO A ANCHOR (3150#) ��� :•• G1S TE'' �UF r•Q.� No. RFo 'i •• E�NE87�3�- • ",,/,,s./ONAL PROVED BYE II V� wu ur�ns�cn� � r' IDaAMI BY: DALE: REV. LETTER JACOBSEN HOMES 1NESE sPEanunWHS a+s AA ND "Druwett ARE C.L.Y. 5-25-95 m =HAL, FROMUARI: AND CO UMENTIAL DRAWING TITLE: P.O. 80X 368 MATERIALS u TE JACOBSEN TO ` COL TIE -DOWN APPL. SAFETY HARBOR. FLORIDA 34695 RECpUiT FOR SR:CM RR'`M uO WST BE DRAWING NUMBER PHONE (813) 726-1138 IDPT COIfWnAL NO SECRET FROM OHM AD—TD-0252 65 ADDENDUM COLUMN TIE -DOWN APPLICATION FLOOR ANCHORING EQUIPMENT CAPABLE OF RESISTING THE WORKING LOAD OF 4000 / MIN. COLUMN STRAPS SINGLE GROUND NOTES: 1. ALL ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS- ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES. Eel MARRIAGE LINE OF Mal -WIDE FLOOR VERTICAL TIE -DOWN TYPE 1. FINISH B. GRADE 1 STEEL STRAPPING 1 1/4- WIDE do 0.035- IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91. STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. ATTACHED TO A ANCHOR (4000#) . . 111►Lluu,.. \ST Ey�v(< Q NO. ENE87 3' PROVED BYE, jM 1 5 19� IVIN INC RDEMI WwIfACi1R!®K7E caaTn,cro� rio swtrt sv+nvrad JACOBSEN HOMES r10T,t 11,w'�»T. uAI� M• ",.LR TNESE srfanunas uro orUwxcs ARE C.L.Y. 5-25-95 m MATERIALS COOBSE' N�MW CA 1lJR1N�C DRAWING TITLE P.O. BOX 368 sua MATU44S ARE PROCS TO THE COL. TIE —DOWN APPI. e+_ SAFETY HARBOR. FLORIDA 34695 RECpprt TAI VECM RIiPM AID WSI BE DRAWING NLIYBER: PHONE (813) 726-1138 IvT CWMTK M SEOV rKV ODM AD—TO-0253 66 ADDENDUM 184" WIDE COLUMN TIE -DOWN APPLICATION COLUMN 'A' COLUMN �� L - - - - ISEE TABLE FOR MAXIMUM SPAN FOR COLUMNS W OR r 'C' COLUMN'0' /COLUMN APPROVED EY SEE TABLE FOR MA1auuM SPAN FOR COLUMNS 'C OR b•_I r � SEE TABLE FOR SPAN COL 'E' SEE TABLE FOR MAX SPAN FOR OFEDLMANUFACTUREDHOME INC. RLICTIONAND SAFETY S TAnDaROS MAR 3 199g COLUMN 'E' COLUMN 'f COLUMN 'G - - ISEE TABLE FOR MA)OIAIY SPAN FOR COLUMN MAXIMUM ALLOWABLE SPAN TYPE OF ANCHORM REO'D (SEE AD -ID -MI. COLUMNS W. V. V OR 'E' COUW 'B' OR V COLUMN 'F• AD-TD-0252 AND ZONE 2 ZONE 3 ZONE 2 ZONE 3 ZONE 2 ZONE 3 AD-M-0253) SEE NOTE 1 EV. 'C W. V W. •C' EXP. •D' EXP. 'C" EXP. V D(P. 'C' EXP. V D(P 'C' EXP. V EW. 'C• EW. V 2 - 3150J ANCHORS 3'1-4' 25'-6" 29'-4' 20'-4' 37'-4' 25'-6" W-4" 20'-4' 37'-4' 25'-6' 29'-4 20'-4' 1 - 31501 ANCHOR 18•-6' 12'-10' 14'-7' 10'-3' IS-6' 12'-10" 14'-7' 10•-3' 16'-6' 12'-10" 14'-7' 10'-3' 1 - 4000/ ANCHOR 23'-8' 16'-4" I8'-7' 13'-0" 23'-8" 16'-4" 18'-7" 13'-0" 23"-8' 16'-4' 18'-7' j 13'-0• R,F. CALCS ` �y Q NOTES: ENGIOMR �c '.,� DAPIA APPROVALwwo p 3 1 yy 1. SEE AD-TD-0251• AD-TD-0252 AND AD-TD-0253 • No. APPROVED BY FOR SPECIFIC INFO. ON ANCHORS. 2. SEE AD-TD-0001 FOR ADDITIONAL NOTES ON ANCHOR 910334 = INSTALLATION.- aoa "-o� OF STATE �' �'O '•. � gyp•' • � ' INC IOE JACOBSEN HOMES NOTICE: THESE SKMCATIONS AND DRAWINGS ARE MA Y M.T. DATE: 2-9-99 REV. LETTER: DRAWING TITLE: MEEI ORIGINAL, PROPRIETARY, AND CMFMTIAL P.O. BOX 368 UMERIALS OF AACOBSEN MANUFACP"G INC. SUCH MATEHN.S ARE PROVIDED TO THE 184° WIDE COL. TIE —DOWN APPL. DRAWING NUMBER: AD—TD-0254 SAFETY HARBOR. FLORIDA 34695 PHONE (727) 726-1138 RECWDfT rOR SPECM KWOM NO MAT BE MPT ODRRDDITIAL AND SECRET FROU OHM 67 ADDENDUM TYPICAL SINGLE WIDE TIE -DOWN PLACEMENT SEE NOTE 2 A B C 24' LARGE OPENING 24' SEE NOTE 1 Jfmlu/ 1L1 ILAL 11L-Wwnn JIM1fl u1 MUiu[ BRACKETS (SEE 120Y N SPACING TABLES -NORMAL AND/OR ALTERNATE- FOR MAXIMUM SPACING ALLOWED). ALSO SEE NOTE I STANDARD VERTICAL TIE -DOWN STRAPS OR ANCHOR BRACKETS TO BE INSTALLED A MUM OF f-0' (24') FROM EACH END OF THE UNIT. NOTES: 1. LARGE OPENING = ANY OPENING WIDER THAN MAX TIE -DOWN SPACING ALLOWED.- 2. VERTICAL TIE -DOWNS MAY EXCEED THE STANDARD VERTck TIE -DOWN SPACINe; ! SO LONG AS, THE AVERAGE SPACING [ (A+B+C) / 3 ] DOES NOT EXCEED THE MAXIMUM TIE -DOWN SPACING REQUIRED ON THE APPROPRIATE VERTICAL/FRAME TIE -DOWN SPACING TABLES (SEE OTHER DETAILS). 3. INSTALL FRAME TIES AT ALL VERTICAL TIE -DOWN LOCATIONS. 4. SEE AD-TO-0001 FOR ADDITIONAL REQUIREMENTS. JACOBSEN HOMES P.O. Box 368 SAFETY HARBOR. FLORIDA 34695 HN PHONE (813) 726-1138 ,YYYYnuuu�Fp 4 C. DO ENE8703571 «•� V • ANCHOR BRACKET AND TIE -DORM DEVICES ARE CERTIRED BY OTHERS N0710Et I DRAWN BY: THESE SPEGFICATM5 AND DRAUNGS ARE ORIGINAL. PROPRIETARY; AND CCNFIDENT4q MATERIALS OF JACOM MANUFACT"O NG SJCH YAILYLIALS ARE PRIMM TO THE RECPIEK FOR SPM PiRPM NO LUST 1E PUT CMMTIAI AM SE V 11= OTTERS 3 ROVED BY l- M 1 5 IM INC, mil va v: m auaia C.L.Y. I "'— 5-31-95 nRE TYP. SINGLE WIDE T/D NUMBER AD—TD-0300 [3A I 68 ADDENDUM TYPICAL MULTI- WIDE TIE -DOWN PLACEMENT SEE NOTE 2, A B C 24' IARGE OPENING 24' SEE NOTE 1 COLUMN SUPPORT TIE -DOWN STRAPS. REQUIRED AT COLUMN LOCATIONS ON EACH SIDE OF OPENINGS GREATER THAN 48'IN WIDTH. MULTI -WIDE FLOOR SHOWN SEPERATED FOR CLARITY V V V L24j' L24'] STANDARD VERTICAL TIE -DOWN STRAPS OR ANCHOR BRACKETS (SEE TIE -DOWN SPACING TABLES -NORMAL AND/OR ALTERNATE- FOR MAXIMUM SPACING ALLOWED). ALSO SEE NOTE I STANDARD VERTICAL TIE -DOWN STRAPS OR ANCHOR BRACKETS TO BE INSTALLED A MAXIMUM OF 2'-0* S24') FROM EACH END OF THE UNIT. FOR TRIPLE WIDE AND LARGER UNIT DESIGNS, INSTALL ``,`,�TI1R11111 fit,,���� ALL TIE -DOWN STRAPS AS SHOWN IN THIS DETAIL ���� r: c i) NOTES: a P vA�� Fo.•Z'� DAPIA APPROVAL I. LARGE OPENING = ANY OPENING WIDER THAN MAX. ME -DOWN SPACING ALLOWED. IENEEL703571 = OVED BY 2. VERTICAL TIE -DOWNS MAY EXCEED THE STANDARD VERTICAL TIE -DOWN SPACI , SO LONG AS, THE AVERAGE SPACING [ (A+B+C) / 3 ] DOES NOT EXCEED THE TA OF , MAXIMUM TIE-DOYN SPACING REQUIRED ON THE APPROPRIATE VERTICAL/FRAME ���'. 6 9�{ �C.�': T 5 10 TIE -DOWN SPACING TABLES (SEE OTHER DETAILS). �F '• ti fqV"•'� .` 3. INSTALL FRAME TIES AT ALL VERTICAL TIE -DOWN LOCATIONS. '•,� �d'/ • .. .. E�1G\ ���•� 4. SEE AD-M-0001 FOR ADDITIONAL REQUIREMENTS �i�j� 10E""""" ANa1tSN6NfQt<T1�ii�TlE-DOWN caar�allosAfmswl�Rof DEVICES ARE CERTIFIED BY OTHERS NOT1DRAWN BY: DATE: REV. LETTER: JACOBSEN HOMES THESE SnaFICATIONS AND DRAwass ARE C.L.Y. 6-1-95 A ORDINAL PROPRIETARY, AND DON1IDENT1A1. DRAWING TITLE: P.O. eox 368 MATMALS OF JACOBSEN MANIFACT"O n?. MULTI —WIDE T/D INC. SO MAIMS ARE PROVIDED TO THE SAFETY HARBOR, FLORIDA 34695 R OPOIT FOR MX RffW No = BE DRAWING NUMBER PHONE (813) 726-1138 JUT OdRFO Rk NO SEaV TIM OWNERS AD-TO-0310 69 ZONE I TIE —DOWNS MARRIAGE WALL I OPENING TIE -DOWN (REQUIRED AT OPENINGS ONLY. OPTIONAL AT SEE DETAIL - 'A' OTHER LOCATIONS.) FRAME TIE -DOWN SEE DETAIL - V SINGLE WIDE TIE —DOWN DOUBLE WIDE TIE —DOWN NOTEI C SECTION MARRIAGE WALL SIMILAR TO I OPENING TIE -DOWN I SINGLE WIDE AT GS (RONLY. EOPTION FRAME TIE -DOWN AL ATD I OTHER LOCATIONS.I P" HT. PULL DOWN TIGHT TO --/ GROUND ANCHOR DETAIL 'A' NOTE: A be B SECTIONS SIMILAR TO DOUBLE WIDE TIE -DOWN TRIPLE WIDE TIE -DOWN BUCKLE WITH 20251 TY MINIMUM SEE DETAIL - 'A' SEE DETAIL - '8' TIE -DOWN STRAP SINGLE HEADED GROUND, ANCHOR (WHEN MARRIAGE WALL TIES AND FRAME TIES ARE LOCATED AND SECURED TO THE SAME GROUND' ANCHOR, A DOUBLE HEADED GROUND ANCHOR MUST BE USED) ALL GROUND ANCHORS MUST BE LISTED TO CARRY THE LOADING IMPOSED BY THE TIE -DOWN STRAPPING (31--b LBS. MAbMUM FOR EACH TIE -DOWN STRAP CONNECTED). DETAIL 'B' TYPICAL TIE -DOWN STRAP (1 1/4' X .035' MINIMUM ZINK COATED STEEL STRAP, OR EQUAL WITH 31SO* CAPACITY MINIMUM) >c 1.S= 4?Z5 r ULT,mm-w Loan a4t�AcITy NOTES: ENGINV i 0F� 1. SEE DETAIL 'B' PAGE 4 NOR MARRIAGE WALL M '�� �O`2'{IFIQgT�E OPENINGS GREATER THAN 49 INCHES. VP To i"7 6 TAI BvTtj� h�. 0335454 2, SEE TIE -DOWN SPACING CHART ON PAGE 2 IfDR s P* . ANCHOR AND TIE -DOWN PLACEMENT. 3. SEE DETAIL 'A' PAGE FOR TYPICAL I -BEAN PIER CONSTRUCTION. STATE OF II P •,: �•� Fc . coato , APPROVED BY velt® OEr, 2 INIM II IC mpNC lw SK[iT�'SLV " JACOBSEN HOMES —cmRS um BY. DATE REV. LETTER* THESE SKWCAMTI DRAVANCS ARE RR 10-31-95 CO ■ CRICINAL. PROPRIETARY, AND CONf1DDITIAI DRAWING i1TlE P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING ZONE I TIE -DOWNS SAFETY HARBOR, FLORIDA 34695 W- SUCH UATERULS ARE PROI= TO THE RECIPIENT FOR SP[M RRPOSES NO MAT BE DRAWING NUMBER PHONE (813) 726-1138 ICPT CONFDENRAL Alm SECIV FROM CIUM AD-Zl -0001 70 ZONE 1 TIE -DOWN SPACING CHART TIE —DOWN SPACING (MAX I —BEAM PIER HEIGHT 33")* SECTION WIDTH I —BEAM SPACING SIDE OVERHANG MAX CENTER SPACING MAX END. SPACING 14' 166' 95" 0' 10 — V - 01.1 14' 160' 95" 6' 10 - 3 rr 2 r - O ° 12' 95" 13" 2' - 0" 12' 82" 0. E_ (n 2'-0" 12' 82" 13" 12 75" 0' lot- 12; 75" 13" TIE —DOWN SPACING (MAX. I —BEAM PIER HEIGHT 48")* SECTION WIDTH I —BEAM SPACING SIDE OVERHANG MAX CENTER SPACING MAX END SPACING 14' 166' 95" 0' 8' ^ I r' '2-'-0" 14' 160' 95" 6' 0r- r` 'Z'-oil 12' 95" 13" 61 r- 6" 7-'-Om 12' 82" 0' a' -loft 12' 82" 13" 12' 75" 0' 12' 75" 13" TYPICAL I -BEAM TTIE -DOWN MAIN FRAME I -BEAM IEND SPAC1NG1 CENTER SPAgNG CENTER SPACING CEN SPACING I SPACING I SPACINGjSPAONGI "I PUCME'NT 51WG>_EWIDES � �oUBI.EWI�ES ENQNE Vq. �� UAMA ArrKUYAu: NOTES: �O�OOj.•''•TIFI 1• TIE -DOWN ANCHORS MUST Bel PLACED INSIDE THE OUTLINE OF `� �. •9J�•'L �: APPROVED BY THE EXTERIOR WALLS OF THE HOME. h0, P045434 2 _ SEC 2. THE ANGLE BETWEEN THE TIE -DOWN STRAP AND THE GROUND - MUST BE BETWEEN 40' AND 50' FOR PIERS UP TO 33 INCHES 7Cs •; STATE OF HIGH, AND NOT GREATER THAN 60' FOR PIERS UP TO 48 INCHES � • 2 � rTOE.K K^^mp+E INC HIGH, UNLESS OTHERWISE SPECIFIED. i�F•••'• :r�OR1OP' N� I ........• G�ti - �'••.SrEAEo EN_..••'• NOTICE: RR DAl 10-31-95 REv. u J AC O B S E N HOMES THESE SPEOnU7MS AND DRAWNNS ARE OICGWR PROPRIETMY, AND WinDEND& DRAWING 71TLE MATERIALS of JACOBSEN uMSACTMNc TIE —GOWN SPACING P.O. BOX 368 INC. SUCH MATERIALS ARE PR04W 10 THE SAFETY HARBOR, FLORIDA 34695 RECPQIT FCR SPECIX RIUM RID LAW U DRAWING NUMBER: HE PHONE (813) 726-1138 IVT HXU3D0 Uk NO SECRET rRW O.M AD-Zl -0010 PAGE 2.- 71 ZONE I TIE -DOWN PLACEMENT TYPICAL I -BEAM TIE -DOWN MAIN FRAME I -BEAM �STE NOTE /1�— MAIN FRAME I -BEAM END SPACINGI it--T�e CENTER SPACING CENTER I SPACING ■ r CENTER I SPACING • e CENTER I SPACING ■ r CENTER I SPACING r END ISPACD�GI DOUBLE WIDE TIE-DOWk PLACEMENT END CENTER CENTER CENTER CENTER CENTER END JrAu"u WAUNU JYAUNG S'AGWc TYPICAL 1-BEAM T1E-DOWN MAIN FRAME I -BEAM •SEE NOTE 111• -SEE NOTE /1-f• MAIN FRAME I -BEAM MAIN FRAME I -BEAM ND END CENTER CENTER JjA.NG SPACING SPACING SPACING TRIPLE WIDE TIE -DOWN PLACEMENT ce c* co 0 0 NOTES: ENGINEER, . DO��♦,♦ DAPIA APPROVAL T' , SEE DETAIL •B• PAGE 4 FOR BLOCKING AND ANCHORING OF ����`'(`(1tIFIC.q O�y♦sue„ APPROVED BY MARRIAGE WALL OPENINGS HIDER THAN 49 INCHES. G F : w NO.0045484 14 • 1 • STATE OF . ..NHOME ��a,,%�.RCIPA Pn NOTICE: I'���} DATE REV, LETTFR JACOBSEN HOMES 1HESE SPEancATONS AND DRAwNGS ARE RR 10-31-95 ■ ORIGINAL. PROPRIETARY. AND CONFIDENTIAL DRANANG TITLE: P.O. BOX 368 MATERIALS OF JACOBSEN UANUFACRONC TIE -DOWN PLACEMENT WC, SO MATERWS ARE PRONDED TO THE SAFETY HARBOR, FLORIDA 34695 RECPfl(f FOR >C PUtPQSES Ala oust BEDRANiNG NUMBER PHONE (813) 726-1138 IVT FOR Ala MORLT n= offs AD-Z1-0020 72 ZONE I INSTALLATIONS 1. FOR HOMES LOCATED IN ZONE I, FOLLOW THE MANUFACTURER'S ZONE 2 INSTALLATION INSTRUCTIONS FOR THE INSTALLATION OF LONGITUDINAL ANCHORS. 2. FOR HOMES LOCATED IN ZONE I ONLY, FOLLOW THE MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR THE INSTALLATION OF SHINGLES AND/OR LAP SIDING. FOR ALL OTHER WIND ZONES REFER TO DETAILS IN THE SET-UP MANUAL AND/OR THIS ADDENDUM. NOTES: AP ROVED BY tz C", FEB 0 1 2000 PINC. L MANUFAMPIED HOME ANSI 71ONANDSAFETY$Waq DS JACOBSEN HOMES THESE SPWCATlau`A DRAW= me Mnnn o.. M.T. 2-1-00 ORMAI. PRONXTARY. AM CQfWRAL DRAWWG 71TLE: O THE P.v. Box J68 WEROLS OF ACOBSEX UAXUFACWRIWC ZONE 1 INST. „ SAFETY HAR$OR. FLORIDA 34695 FXXV rt rQl V fPlNO'SiS AND ITW It PHONE (727) 726-1138 KP1 CCXMINna 00 SEOWT MOM any pRAY+kiC NUAIBfR: AD— Z1-0100 73 ADDENDUM FOR INTERSECTING UNITS MAIN UNIT /DORMER I \ TRIPLE WIDE OR QUAD WIDE SECTION(S) L I TI MAXIMUM PIER HEIGHT FOR VARIOUS ZONES (REFER ALSO TO SIDEWALL TIE -DOWNS MAXIMUM HEIGHT} Z411E2 70NE EXPOSURE V 90' 56' EXPOSURE V 39' 46' LONGITUDINAL TIES ONLY REWIRED 0 EA. HALF OUTSIDE BEAM INS END, EXCEPT FOR ZONE 3 EXP. 'D' THEN 2 REWIRED EA HALF (IE. OX EA. BEAM, ETC..) VERTICAL AND DIAGONAL TIES INSTALLED ALONG THE SIDEWALLS SAME AS THE MAW UNIT. VERTICAL TIES AT CENTER LINE REQUIRED ONLY AT COLUMN SUPPORTS PER DOUBLE WIDE CONNECTION REQUIREMENTS. 24' MAXIMUM SPACING TO FIRST SIDWALL TIE FROM EACH END OF THE UHT (SAME AS TYP. DOUBLE WIDE TIE -DOWN REQUIREMENTS). 2 LMOTUDNAL TIES REWIRED AT EACH HALF THIS END ONLY. CONNECT THE TRIPLE WIDE OR QUAD. WIDE SECTION(S) TO THE DORMER AND MAIN UNIT PER DOUBLE WIDE MARRIAGE LINE DETAILS AS OUTLINED IN THE SET-UP MANUAL (EXCEPTION: NAILING ONLY IS REQUIRED AT FLOOR CONNECTION. NO STRAPS ARE REQUIRED TO BE INSTALLED ACROSS THE FLOOR CONNECTION AT THIS AREA) tttllllllll//�/��'i NOTES: !ter s DAPIA APPROVAL ' `` �e F •F2 -= , I. FOR WAD SECTIONS, EACH 'DOUBLE SECTION' OF THE UNIT 9iAll BE DESIGNEDQ` N0. O '•. INDEPENDENT OF THE OTHER STRUCTURE. (IL SHEARWALLS, TIE -DOWNS, RIDGE -APPROVED BYE_ BEAMS, COLUMN SUPPORTS, ETC... ARE CALCULATED FOR EACH MULTI -SECTION.) — 0 _ .1<;N 1 5 M Z. MIA INC, NOT JACOBSEN HOMES THESE sPEOnCATTIONSJA1D DRAWNGS ARE DRAWN BY. C.L.Y. °" 5-16-95 �" LETTER: ■ OlaaNAL PROMETARY. AND COW MTLOL DRAVANG TITLE: YATERIMS OF JACOM Un"ACMMG „ P.O. BOX 368 WC. M YATERALS ARE PROVM TO 114E ADDENDUM -INT. UNITS SAFETY HARBOR, FLORIDA 34695 MOMENT FOR SKCfIC RIIPOSES kO MM BE DRAMiNG NUMBER PHONE (813) 726-1138 IIEPT CWMTUI AM SCOV TROY ODOM QUADADDI 74 ALT. ROOF ASSEMBLY FOR MULTI- WIDES CENTER IJNE CONNECTION FOR WAD UNITS IS THE SANE AS FOR THE MAIN UNIT (REFER TO SET-UP DETAILS). 30 GA. GALV. STEEL STRIP INSTALLED OVER MATING LINE JOINT (SEE PLAN VIEW BELOW) ROOF PERIMETER RAIL --o' OR RIDGE BEAM CROSS-SECTION 30 GA. GALV. STEEL STRIP 8- X LENGTH OF ROOF SSECTIONS MAY BE OVERLAPPED 2 ION.) W/STAPLES AS SHOWN. INSTALL ROOF CAP PER SET- UP MAN. OVER GALV. STRIP. (SEE NOTE 1) 31 X 5' LAC SCREWS 18' O.C. (ZONES 2 k 3) STAGGERED L— 30 GA. CALV. STEEL STRIP SECURED NTH 7/16- X 16 GA. STAPLES FULL PENETRATION INTO DECKING 2 " O.C. MAX. SPACING (TYP.) �»uliUfii NOTES: ENGIN�F``�` 0 • 10 DAPIA APPROVAL' p % 1. 30 CA. GALV. STRIPS USED MAY BE W9( WIND DEFLECTORS � : , Q• REMOVED FROM ROOF IN ORIGINAL CONDITION NO. (EXCEPT FOR STAPLE HOLES). ENE8703571 JUN , 5 STEEL STRIP MAY BE CONTINUOUS OR PIECED. 2. SHINGLES IN THE DORMER AREA OF THE MAIN UNIT MAY - INC SHIPPED LODSE AND INSTALLED ON STE AFTER - • Q 1 L V THE UNITS HAVE BEEN ATTACHED TO PREVENT ANY % �,�'•• / 9 �c.�': '""�'�� TRANSIT DAMAGE AND TO ENSURE THE SHINGLES UNE-UP '��� �' ' �D) Q`_ ••�C� ���•a�� FROM ONE SECTION TO THE NEXT ����i �s/�A/ A 1 •. EN�����` JACOBSEN HOMES N017CElDH" p1 ""• ' 1HESE sPEancATs AND oRArcs HARE ' C.L.Y. 5-16-95 CRONAL, PROPRIETARY, AND CCH MTIAL DRAWING TITLE: P.O. BOX 368 MATITOALS OF JACaesF1C YNCUFACMUG ALT. ROOF ASSEMBLY DC- la MATLRULS ARE PRO41Df0 TO THE SAFETY HARBOR. FLORIDA 34695 RECPlD f fOR SPECM PJMO AHD MM K DRAWING NUMBER HE PHONE (B13) 726-1138 IvT O mTLAL AID SECIIET FRaI omm QUADADD2 75 F-10FT-1 EIEINF� EIMWF-1 iE]E:]nE] JACOBSEN HOMES 600 PACKARD COURT SAFETY HARBOR, FLORIDA 34695 . (727) 726-1-138