Loading...
HomeMy WebLinkAboutEngineering �3 V3eQ� PAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie,FL 34984 Phone(772) 785 - 9888 ?� Email pwelchinc@aol.com st Sv pc e4/�iM Coon G JUNE 6,2017 ( Q� � F` RE: SHUTTER CHANNEL LEDGER 9232 SHORT CHIP CIR SAINT LUCIE COUNTY,FL SCOPE OF WORK INSTALL LEDGER ABOVE REAR SLIDING GLASS DOOR FOR ACCORDIAN SHUTTER CHANNEL SUPPORT. NOTES: 1) THE CONTRACTOR,SUBCONTRACTOR, SUPPLIER,ECT.SHALL VERIFY ALL DEviENSIONS, CONDITIONS AT JOB SITE,PLANS, SPECIFICATIONS,ECT. 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. 3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4) ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE(FBC)2014,AND FBC 2014 RESIDENTIAL. 5) ALL ADDITIONS,REPAIRS,AND ALTERATIONS MUST COMPLY WITH THE F.B.0 2014 FOR EXISTING BUILDINGS. STRUCTURAL NOTES 1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10. 2) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. 3) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALATION OF HARDWARE IS NOT PERMITED. 4) UNLESS OTHERWISE NOTED,THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICIES. ( �I IL YVELCH INC. ,��a ,, .r:� Cr��ELECT-CIVILENG ,,� �....t.�-0,,.BILTMORE ST.;h-114 -�• -, ..�1 . ,.;' .�-, 3;,.,:E°1 ST.P—UCIE,FL 34984 FLA REG NO2994.5 2017 . ----- - - U ---- Ticcam - jso I uA�.JtJfce. L __. 1ZaD_lSG'E okp P-r VA/ L. ' .' --I�-�D►-�7_�i�- v�J.-►-TIC—� OK - ff . - i '[1 = :__ .u: _�.i :_C�_-L ; pad --- -- �_- L.09P _ : _S --u-TTE 'kUL WELCH INC. i%,`4E',+ELECT-CIVIL EWG 1RIi_TMCAE ST.--114 ` ORT ST.LUCIE,FL 34984 1 6 WELCH,R.E.FLA REG NO 29945 SHUTTER CHANNEL LEDGER 9232 SHORT CHIp CIR. SAINT LUCIE COUNTY,FL u tjN t® IG 2017 r3 j - Y Planning&Development Services Department ® Building&Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982—(772)462-1553 Certification for Design Load Compliance Project Name: SHUTTER CHANNEL LEDGER' Project Address: 9232 SHORT CHIP CIR. Permit#: IL�J p ccupancy Tye: R Construction Type: V INSTRUCTIONS FOR USE: •This certification must be completed,signed,and sealed by the design professional of record. •Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following: o New Residences(single or multi-family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. *Note:Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official.Contact the#above for questions., DESIGN PARAMETERS AND ASSUMPTIONS USED:(complete all that anolv) 1.DESIGN CODE:Florida Building .Code 2014 Edition with 20 Supplements using ASCE 7-10 2.Structure Designed as(check one): X Enclosed Partially Enclosed Open 3.Risk Category:_I X 11 111 IV Exposure Category: _B X C D 4.Design Wind Velocity 160 mph 124 ASD N/A LRFD End Zone Width: 5 . ft 5.Mean Roof Height: 20 ft Roof Pitch: N/A :12 Parapet: N/A ft 6.Components&Cladding Design Pressures Used:(PSF;based on 10sgft @ 15'MRH,clearly label on all plan openings): N/A N/A N/A 35.5 35.5 N/A Zone 1: N/A Zone 2: N/A Zone 3: N/A Zone 4: -38.5 Zone 5: -47.6 Garage: N/A 7.Design Loads:Floor: N/A PSF Roof/Dead: N/A PSF Roof/Live: N/A Balcony:-N/A PSF Dock: N/A . PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF/CONCENTRATED 8.Were Shear Walls Considered For Structure?_X Yes Not Applicable Explain Why Not: 9.Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10.Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT.* I certify that,to the best of my knowledge and belief,the attached plans&specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St.Lucie Countyi1 also certify;that structural elements depicted on these plans provide adequate resistance to the design forces�speif)edo':�'�//// ., Paul Welch P.E. 29945 / 5115 Print Name Cert#&Co.Cert Auth. Paul Welch Inc. 6 6/2017. S! riature� .e ncl Seal w 1984 S.W..Biltmore St.Suite#114 Port St.Lucie, FL Company Name&Address sf�C��!'RormCt�i320�]2(fewsed 3/15/12(is) ,'•// yam/ n re l