Loading...
HomeMy WebLinkAboutProduct Approval (2)7/11/2Fi17 Florida Building Code Online File Copy I j E BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff . BCIS Site Map j links f Search I FiCI'i(jr7 A Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application Detail =i FL # Application Type FL5325-R6 , Revision Code Version 2614 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year.,(of Standard) Equivalence of Product Standards Certified By Sections from the Code SDP Inc. 410-130 Bridgeland Ave Toronto, (866) 747-4035 Ext4 sdipede@sdp-products.com Sandra DiPede sdipede@sdp-products.com Sandra DiPede 410-130 Bridgeland Ave Toronto (416)780-1700 sa ndrod ipede@ bellnetca Sandra DiPede 410-130 Bridgeland Ave Toronto (416)780-1700 sa ndrod ipede@bellnet.ca Roofing llnderlayments JUL ; ? r'g,3 PE1=i JIII--I G' St Lucie i:,,ountj.L Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer d Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 Intertek Testing Services NA, Inc. 11/18/2017 John W. Knezevich, PE Validation Checklist - Hardcopy Received FL5325 R6 COI 2015 01 COI Nieminen^odf 1507.2.3 1507.2.4 https:IlHoHdabuilding.org/prlpr app dtl.aspx7param=wGEVXQwtDgvBaw2gXbdthvuV98c7IHpC6fu7nYigY]Up/`3d 1/2 7/11/2017 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Florida Building Code Online 1507.2.8 1507.3.3 1507.4.5.1 1507.4.5.2 1507.5.3 1507.7.3 1507.8.3 1507.9.3 1507.9.5 1518.4 1523.6.5.2.1 1523.6.5.2.9 Method 2 Option B 04/29/2015 04/30/2015 05/10/2015 06/23/2015 FIL # Model, Number or Name Description 5325.1 PALISADE Roofing Synthetic Roofing Underlayments Underayments Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5325 R6 II 2015 04 FINAL ER SDP UNDERLAYMENTS FL5325- R6.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: 1.) PALISADE is for use in non-HVHZ and Evaluation Reports HVHZ jurisdictions. 2.) PALISADE SA -HT is not for use FL5325 R6 AE 2015 04 FINAL ER SDP UNDERLAYMENTS FL5325- R6.Ddf in HVHZ. 3.) Refer to ER Section 5 for Limits of Use.' Created by Independent Third Party: Yes Qacic PoCi Contact Us :: 2601 Blair Stone Road, Ibllahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for offldal communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: e— — M .�::,-CreditmCaid Sak securi tF" ai I_TR ICS https:lMoridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgvBaw2gXbdthvuV98c7lHpC6fu7nYgYIU%3d 2/2 M TRINITY ERD EVALUATION REPORT SDP, Inc. 410-130 Bridgeland Avenue Toronto, Ontario M6A 1Z4 Canada EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report S19010.07.09-112 F15325-R6 Date of Issuance:07/03/2009 Revision 2: 04/29/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: PALISADETM Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 04/29/2M. This does not serve as an electronically signed document signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. K �,i} TRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: PALISADETM Roof Underlayments, as produced by SDP, Inc., have demonstrated compliance with the intent of the following sections of the Florida Building Code through testing in accordance with the applicable sections of the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.3,1507.2.8,1507.4.5.1, Unrolling, Breaking Strength, Pliability, Loss ASTM D226 2006 1507.4.5.2,1507.5.3, 1507.5.3.2, on Heating 1507.7.3,1507.7.3.2, 1507.8.3, 1507.8.3.2, 1507.9.3, 1507.9.3.2, 1507.9.5,1518.4 1518.4 Unrolling, Pliability, Behavior on Heating, ASTM D2626 2004 Breaking Strength, Water Vapor Permeance 1507.2.4,1507.5.3 Unrolling, Thickness, Max Load, Elongation ASTM D1970 2009 at Break, Adhesion, Thermal Stability, Low Temp Flex, Tear Resistance, Moisture Vapor Permeance, Self-Sealability 1507.3.3 Installation Practice FRSA/TRI April 2012 (04-12) 2012 1523.6.5.2.1 Dimensional Stability, Tear Resistance, TAS 104 1995 Breaking Strength, Water Absorption, Low Temp Flex, UV Exposure, Accelerated Aging, Cyclic Elongation, Water Vapor Transmission 1523.6.5.2.9 Comparative Rupture TAS 117, Appendix B 1995 TAS 110 Accelerated Weathering TAS 110 2000 3. REFERENCES: Kniinl Examination Reference Date ERD (TST6049) Physical Properties 54240.10.06 10/03/2006 ERD (TST6049) Physical Properties & Rupture SO404C.12.05-R2 02/23/2009 ERD (TST6049) Accelerated Weathering 537000.06.11 06/14/2011 ICC-ES (EVL2396) IBC/IRC Compliance ESR-1847 03/O1/2015 Miami -Dade (CERiS92) HVHZ Compliance 11-0714.05 11/10/2011 ITS-ETL/WH (QUA1673) Quality Control Inspection Report 11/18/2014 4. PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlayments: 4.1.1 PALISADETM is a synthetic roofing underlayment comprised of a polyolefin-coated, woven construction with dual skid resistant surfaces. PALISADETM is acceptable for use in non-HVHZ and HVHZ jurisdictions. Refer to Limits of Use herein. 4.2 Self -Adhering Underlayments: 4.2.1 PALISADETM SA -HT is a self -adhering roofing underlayment comprised of a polyolefin-coated, woven construction with skid resistant upper surface and self -adhering bottom surface. PALISADE' SA -HT is not for use in HVHZ. Refer to Limits of Use herein. Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation ReportS19010.07.09-R2 FL5325-R6 Revision 2: 04/29/2015 Page 2 of 5 TRINITY 1 ERD S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose 5.2 Non-HVHZJurisdictions: 5.2.1 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.2.2 PALISADETM Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.2.3 Allowable Roof Covers: Table 1: Roof Cover'Options Asphalt Wood Shakes Underl ayment Nail -On Tile Foam -On Tile Metal Slate Shingles & Shingles PALISADE- Yes Yes No Yes Yes Yes (as base layer only) PALISADE- SA -HT Yes No No Yes Yes Yes 5.2.4 Allowable Substrates: PALISADE— SA -HT adhered to plywood or to mechanically attached PALISADETM. 5.2.5 Exposure Limitations: PALISADE' shall not be left exposed for longer than 180-days after installation. PALISADETM SA -HT shall not be left exposed for longer than 30-days after installation 5.3 HVHZ Jurisdictions: 5.3.1 PALISADETM SA -HT is not for use in HVHZ 5.3.2 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3.3 This Evaluation is for prepared roofing applications. Minimum deck requirements shall be compliant with applicable FBC sections. 5.3.4 PALISADE— shall not be applied in hot asphalt. 5.3.5 PALISADE— shall be installed in strict compliance with the requirements for ASTM D226, Type II or ASTM D2626 underlayment in Section 1518 for the type of prepared roof covering to be installed. 5.3.6 PALISADETM may be used with asphalt shingles, the roofs (base layer only), non-structural metal roofing / metal shingles, quarry slate, slate -type shingles and wood shakes & shingles. For the roof applications, PALISADETM shall be mechanically attached as an anchor sheet in accordance with Section 6.4 herein, followed by Tamko TW Metal and Tile Underlayment (NOA 12-0406.07), GAF UnderRoof 2 (NOA 13-1104.11) or CertainTeed Flintlastic SA Cap (NOA 14-0724.16). 5.3.7 If PALISADE' is not specifically listed in the prepared roof covering NOA, this report may be submitted to the AHJ or Miami -Dade Product Control Dept., along with fire classification information, for their consideration. 5.3.8 PALISADE' underlayment shall not be left exposed for longer than 180-days after installation. 5.4 All products listed herein shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3 requirements. Exterior Research and Design, LLC. Evaluation Report S39030.07.09-112 Certfflcate of Authorization OW03 FL5325-116 Revision 2: 04/29/2015 Page 3 of 5 N 6. AINITY ERD. INSTALLATION: 6.1 PALISADETM Roof Underlayments shall be installed in accordance with SDP published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick. 6.3 Non-HVHZ Jurisdictions- 6.3.1 PALISADETM: Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.1.1 Non -Tile Applications: PALISADE— is installed horizontally with the printed side up, and with 3-inch horizontal laps and 6-inch vertical laps. Overlaps must run with the flow of the water in a shingle pattern. The underlayment is only attached to the roof deck with roofing nails (smooth or ring-shanked) having 1-inch minimum diameter plastic or steel caps compliant with FBC 1507.2.6. Cap nails are spaced at 6 inches on center at vertical laps, and at 11 inches on center at horizontal laps. In the field area, apply fasteners at 13 inches spaced vertically and 22 inches on center horizontally. All caps (including nails) must be fully flush with the underlayment surface. Do not install fasteners over unsupported areas/voids. Repair all tears, holes, or damage to the underlayment. For slopes less than 4:12, use a full 20" half lap over the underlying course. Apply underlayment up all abutments at least 6 inches. In non-HVHZ high wind regions where Vint > 181 mph (Vasd > 140 mph) or exposure beyond 30 days, increase the fastener density to cap nails spaced 3 inches on center at vertical laps, and at 5.5 inches on center at horizontal laps. In the field area, apply fasteners at 6.5 inches spaced vertically and 11 inches on center horizontally. In addition, secure laps by folding all laps over before nailing, or taping securely across lap seams using exterior grade sheathing tape, or sealants such as roofing cement (asbestos free meeting ASTMD4586), EPDM or butyl to seal laps. 6.3.1.2 Nail -On Tile Applications, Base Layer in 2 Ply System: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein using PALISADETM as the mechanically attached base ply in a 2 ply underlayment system, followed by Tamko TW Metal and Tile Underlayment (FL12328), GAF UnderRoof 2 Polyester -Surfaced Leak Barrier (FL10626) or CertainTeed Flintlastic SA Cap (FL11288) as the top layer. For mechanically fastened tile roofing, refer to SDP published installation instructions, but not less than FRSA/TRI April 2012 (04-12), Table 1. 6.3.2 PALISADE SA-HTTM: Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. The installer is responsible to determine whether priming is required to ensure PALISADE— SA -HT will stay adhered to the substrate. 6.3.2.1 Non -Tile Applications: PALISADE SA-HTTM is installed horizontally with the printed side up, and with 3-inch horizontal laps and 6-inch vertical laps. Starting at the low point, and with salvage edge at the high point, position horizontally a full roll or cut the membrane into 10-15 ft. (3-5m) lengths and re —roll loosely. Peel back 1-2 ft. (300-600mm) of release film, align the membrane, and continue to peel the release film from the membrane. Press the membrane in place with heavy hand pressure. Apply uniform pressure to the membrane roll side and end laps to insure water tightness and bonding to the substrate. Always work from the low to the high point of the roof. Follow good roofing practice by orientating PALISADE -SA -HT - so side laps shed water. Apply the membrane in valleys before the membrane is applied to the eaves. For valley and ridge application, peel the release film; center the sheet over the valley or ridge, drape, and press into in place. Work the center of the valley or ridge outward in each direction. Following placement along the eaves, continue application of the membrane up slope. If nailing of the membrane is necessary on steep slopes, especially during hot or cold weather, back nail and cover the nails by overlapping with the next sheet. Exterior Research and Design, LLG Certij+cate of Authorhation AW03 Evaluation Report S19030.07.09-R2 FL5325-RG Revision 2: 04/29/2015 Page 4 of 5 - `,�J TRINITY t ER® 6.4 HVHZ Jurisdictions: 6.4.1 System E(1): Underlayment mechanically fastened to deck Deck Type 1: Wood, Non-Irsulated Deck Description: Min. 19/32" plywood or wood plank Underlayment: One or more plies of PALISADETM' with minimum 4" wide head laps and minimum 6" wide end laps, mechanically fastened to deck. Fastening: HVHZ Approved nails and tin caps 6" o.c. at lap and three equally spaced staggered rows 12" o.c. in the field. - Surfacing: HVHZ Approved asphalt shingle, non-structural metal, wood shakes & shingles or slate. 6.4.2 System E(2): Base underlayment mechanically fastened to deck, top layer adhered Deck Type 1: Wood, Non -Insulated Deck Description: Min.19/32" plywood or wood plank Base Layer: One or more plies of PALISADE' with minimum 4" wide head laps and minimum 6" wide end laps, mechanically fastened to deck. Fastening: HVHZ Approved nails and tin caps 6" o.c. at lap and three equally spaced staggered rows 12" o.c. in the field. Top Layer: Tamko TW Metal and Tile Underlayment (NOA 12-0406.07), GAF UnderRoof 2 (NOA 13- 1104.11) or CertainTeed Flintlastic SA Cap (NOA 14-0724.16), self -adhered to the base layer. See current FBC HVHZ approval for installation guidelines and limits of use of top layer. Surfacing: HVHZ Approved asphalt shingle, non-structural metal, wood shakes & shingles, slate or tile. Note: For tile applications, AH1 shall verify that top layer underlayments listed herein hold current HVHZ Product Approval and/or Miami -Dade NOA for use as a tile underlayment. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the manufacturer or the named CIA entity for information on plants covered under Rule 61G20-3 QA requirements. 9. QUALITY A58URANCE ENTITY: Intertek Testing Services NA Inc. — ETL/Warnock Hersey— QUA1673; (90S) 678-4913 - END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Cen ficote of Authorization 09.503 Evaluation Report S19030.07.09-R2 FL5325-R6 Revision 2: 04/29/2015 Page 5 of 5