HomeMy WebLinkAboutProduct Approval (2)7/11/2Fi17 Florida Building Code Online File Copy
I j E
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff . BCIS Site Map j links f Search I
FiCI'i(jr7
A
Product Approval
USER: Public User
Product Approval Menu > Product or Application
Search > Application Detail
=i
FL #
Application Type
FL5325-R6 ,
Revision
Code Version
2614
Application Status
Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year.,(of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
SDP Inc.
410-130 Bridgeland Ave
Toronto,
(866) 747-4035 Ext4
sdipede@sdp-products.com
Sandra DiPede
sdipede@sdp-products.com
Sandra DiPede
410-130 Bridgeland Ave
Toronto
(416)780-1700
sa ndrod ipede@ bellnetca
Sandra DiPede
410-130 Bridgeland Ave
Toronto
(416)780-1700
sa ndrod ipede@bellnet.ca
Roofing
llnderlayments
JUL ; ? r'g,3
PE1=i JIII--I G'
St Lucie i:,,ountj.L
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
d Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
Intertek Testing Services NA, Inc.
11/18/2017
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL5325 R6 COI 2015 01 COI Nieminen^odf
1507.2.3
1507.2.4
https:IlHoHdabuilding.org/prlpr app dtl.aspx7param=wGEVXQwtDgvBaw2gXbdthvuV98c7IHpC6fu7nYigY]Up/`3d 1/2
7/11/2017
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Florida Building Code Online
1507.2.8
1507.3.3
1507.4.5.1
1507.4.5.2
1507.5.3
1507.7.3
1507.8.3
1507.9.3
1507.9.5
1518.4
1523.6.5.2.1
1523.6.5.2.9
Method 2 Option B
04/29/2015
04/30/2015
05/10/2015
06/23/2015
FIL #
Model, Number or Name
Description
5325.1
PALISADE Roofing
Synthetic Roofing Underlayments
Underayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL5325 R6 II 2015 04 FINAL ER SDP UNDERLAYMENTS FL5325-
R6.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: 1.) PALISADE is for use in non-HVHZ and
Evaluation Reports
HVHZ jurisdictions. 2.) PALISADE SA -HT is not for use
FL5325 R6 AE 2015 04 FINAL ER SDP UNDERLAYMENTS FL5325-
R6.Ddf
in HVHZ. 3.) Refer to ER Section 5 for Limits of Use.'
Created by Independent Third Party: Yes
Qacic PoCi
Contact Us :: 2601 Blair Stone Road, Ibllahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for offldal communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
e— — M
.�::,-CreditmCaid
Sak
securi tF" ai I_TR ICS
https:lMoridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgvBaw2gXbdthvuV98c7lHpC6fu7nYgYIU%3d 2/2
M
TRINITY ERD
EVALUATION REPORT
SDP, Inc.
410-130 Bridgeland Avenue
Toronto, Ontario M6A 1Z4
Canada
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report S19010.07.09-112
F15325-R6
Date of Issuance:07/03/2009
Revision 2: 04/29/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: PALISADETM Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 04/29/2M. This does not serve as an electronically signed
document signed, sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
K
�,i} TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: PALISADETM Roof Underlayments, as produced by SDP, Inc., have demonstrated compliance with the
intent of the following sections of the Florida Building Code through testing in accordance with the applicable sections of the
following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.3,1507.2.8,1507.4.5.1,
Unrolling, Breaking Strength, Pliability, Loss
ASTM D226
2006
1507.4.5.2,1507.5.3, 1507.5.3.2,
on Heating
1507.7.3,1507.7.3.2, 1507.8.3,
1507.8.3.2, 1507.9.3, 1507.9.3.2,
1507.9.5,1518.4
1518.4
Unrolling, Pliability, Behavior on Heating,
ASTM D2626
2004
Breaking Strength, Water Vapor
Permeance
1507.2.4,1507.5.3
Unrolling, Thickness, Max Load, Elongation
ASTM D1970
2009
at Break, Adhesion, Thermal Stability, Low
Temp Flex, Tear Resistance, Moisture
Vapor Permeance, Self-Sealability
1507.3.3
Installation Practice
FRSA/TRI April 2012 (04-12)
2012
1523.6.5.2.1
Dimensional Stability, Tear Resistance,
TAS 104
1995
Breaking Strength, Water Absorption, Low
Temp Flex, UV Exposure, Accelerated
Aging, Cyclic Elongation, Water Vapor
Transmission
1523.6.5.2.9
Comparative Rupture
TAS 117, Appendix B
1995
TAS 110
Accelerated Weathering
TAS 110
2000
3. REFERENCES:
Kniinl
Examination
Reference
Date
ERD (TST6049)
Physical Properties
54240.10.06
10/03/2006
ERD (TST6049)
Physical Properties & Rupture
SO404C.12.05-R2
02/23/2009
ERD (TST6049)
Accelerated Weathering
537000.06.11
06/14/2011
ICC-ES (EVL2396)
IBC/IRC Compliance
ESR-1847
03/O1/2015
Miami -Dade (CERiS92)
HVHZ Compliance
11-0714.05
11/10/2011
ITS-ETL/WH (QUA1673)
Quality Control
Inspection Report
11/18/2014
4. PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlayments:
4.1.1 PALISADETM is a synthetic roofing underlayment comprised of a polyolefin-coated, woven construction with dual skid
resistant surfaces. PALISADETM is acceptable for use in non-HVHZ and HVHZ jurisdictions. Refer to Limits of Use herein.
4.2 Self -Adhering Underlayments:
4.2.1 PALISADETM SA -HT is a self -adhering roofing underlayment comprised of a polyolefin-coated, woven construction with
skid resistant upper surface and self -adhering bottom surface. PALISADE' SA -HT is not for use in HVHZ. Refer to Limits
of Use herein.
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation ReportS19010.07.09-R2
FL5325-R6
Revision 2: 04/29/2015
Page 2 of 5
TRINITY 1 ERD
S. LIMITATIONS:
5.1
This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose
5.2
Non-HVHZJurisdictions:
5.2.1
Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this
product.
5.2.2
PALISADETM Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation
combined with supporting data for the prepared roof covering.
5.2.3
Allowable Roof Covers:
Table 1: Roof Cover'Options
Asphalt
Wood Shakes
Underl ayment
Nail -On Tile
Foam -On Tile
Metal
Slate
Shingles
& Shingles
PALISADE-
Yes
Yes
No
Yes
Yes
Yes
(as base layer only)
PALISADE- SA -HT
Yes
No
No
Yes
Yes
Yes
5.2.4 Allowable Substrates:
PALISADE— SA -HT adhered to plywood or to mechanically attached PALISADETM.
5.2.5 Exposure Limitations:
PALISADE' shall not be left exposed for longer than 180-days after installation.
PALISADETM SA -HT shall not be left exposed for longer than 30-days after installation
5.3 HVHZ Jurisdictions:
5.3.1 PALISADETM SA -HT is not for use in HVHZ
5.3.2 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.3.3 This Evaluation is for prepared roofing applications. Minimum deck requirements shall be compliant with applicable
FBC sections.
5.3.4 PALISADE— shall not be applied in hot asphalt.
5.3.5 PALISADE— shall be installed in strict compliance with the requirements for ASTM D226, Type II or ASTM D2626
underlayment in Section 1518 for the type of prepared roof covering to be installed.
5.3.6 PALISADETM may be used with asphalt shingles, the roofs (base layer only), non-structural metal roofing / metal shingles,
quarry slate, slate -type shingles and wood shakes & shingles.
For the roof applications, PALISADETM shall be mechanically attached as an anchor sheet in accordance with Section 6.4
herein, followed by Tamko TW Metal and Tile Underlayment (NOA 12-0406.07), GAF UnderRoof 2 (NOA 13-1104.11) or
CertainTeed Flintlastic SA Cap (NOA 14-0724.16).
5.3.7 If PALISADE' is not specifically listed in the prepared roof covering NOA, this report may be submitted to the AHJ or
Miami -Dade Product Control Dept., along with fire classification information, for their consideration.
5.3.8 PALISADE' underlayment shall not be left exposed for longer than 180-days after installation.
5.4 All products listed herein shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3 requirements.
Exterior Research and Design, LLC. Evaluation Report S39030.07.09-112
Certfflcate of Authorization OW03 FL5325-116
Revision 2: 04/29/2015
Page 3 of 5
N
6.
AINITY ERD.
INSTALLATION:
6.1 PALISADETM Roof Underlayments shall be installed in accordance with SDP published installation requirements subject
to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate with Elastocol Stick.
6.3 Non-HVHZ Jurisdictions-
6.3.1 PALISADETM:
Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Sections 1507
for the type of prepared roof covering to be installed.
6.3.1.1 Non -Tile Applications:
PALISADE— is installed horizontally with the printed side up, and with 3-inch horizontal laps and 6-inch vertical laps.
Overlaps must run with the flow of the water in a shingle pattern. The underlayment is only attached to the roof deck
with roofing nails (smooth or ring-shanked) having 1-inch minimum diameter plastic or steel caps compliant with FBC
1507.2.6. Cap nails are spaced at 6 inches on center at vertical laps, and at 11 inches on center at horizontal laps. In the
field area, apply fasteners at 13 inches spaced vertically and 22 inches on center horizontally. All caps (including nails)
must be fully flush with the underlayment surface. Do not install fasteners over unsupported areas/voids. Repair all
tears, holes, or damage to the underlayment. For slopes less than 4:12, use a full 20" half lap over the underlying
course. Apply underlayment up all abutments at least 6 inches.
In non-HVHZ high wind regions where Vint > 181 mph (Vasd > 140 mph) or exposure beyond 30 days, increase the
fastener density to cap nails spaced 3 inches on center at vertical laps, and at 5.5 inches on center at horizontal laps. In
the field area, apply fasteners at 6.5 inches spaced vertically and 11 inches on center horizontally. In addition, secure
laps by folding all laps over before nailing, or taping securely across lap seams using exterior grade sheathing tape, or
sealants such as roofing cement (asbestos free meeting ASTMD4586), EPDM or butyl to seal laps.
6.3.1.2 Nail -On Tile Applications, Base Layer in 2 Ply System:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein using PALISADETM as the
mechanically attached base ply in a 2 ply underlayment system, followed by Tamko TW Metal and Tile Underlayment
(FL12328), GAF UnderRoof 2 Polyester -Surfaced Leak Barrier (FL10626) or CertainTeed Flintlastic SA Cap (FL11288) as
the top layer.
For mechanically fastened tile roofing, refer to SDP published installation instructions, but not less than FRSA/TRI April
2012 (04-12), Table 1.
6.3.2 PALISADE SA-HTTM:
Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type
of prepared roof covering to be installed.
The installer is responsible to determine whether priming is required to ensure PALISADE— SA -HT will stay adhered to
the substrate.
6.3.2.1 Non -Tile Applications:
PALISADE SA-HTTM is installed horizontally with the printed side up, and with 3-inch horizontal laps and 6-inch vertical
laps. Starting at the low point, and with salvage edge at the high point, position horizontally a full roll or cut the
membrane into 10-15 ft. (3-5m) lengths and re —roll loosely. Peel back 1-2 ft. (300-600mm) of release film, align the
membrane, and continue to peel the release film from the membrane. Press the membrane in place with heavy hand
pressure. Apply uniform pressure to the membrane roll side and end laps to insure water tightness and bonding to the
substrate.
Always work from the low to the high point of the roof. Follow good roofing practice by orientating PALISADE -SA -HT -
so side laps shed water. Apply the membrane in valleys before the membrane is applied to the eaves. For valley and
ridge application, peel the release film; center the sheet over the valley or ridge, drape, and press into in place. Work
the center of the valley or ridge outward in each direction. Following placement along the eaves, continue application
of the membrane up slope. If nailing of the membrane is necessary on steep slopes, especially during hot or cold
weather, back nail and cover the nails by overlapping with the next sheet.
Exterior Research and Design, LLG
Certij+cate of Authorhation AW03
Evaluation Report S19030.07.09-R2
FL5325-RG
Revision 2: 04/29/2015
Page 4 of 5
-
`,�J TRINITY t ER®
6.4 HVHZ Jurisdictions:
6.4.1 System E(1):
Underlayment mechanically fastened to deck
Deck Type 1:
Wood, Non-Irsulated
Deck Description:
Min. 19/32" plywood or wood plank
Underlayment:
One or more plies of PALISADETM' with minimum 4" wide head laps and minimum 6" wide end
laps, mechanically fastened to deck.
Fastening:
HVHZ Approved nails and tin caps 6" o.c. at lap and three equally spaced staggered rows 12"
o.c. in the field.
- Surfacing:
HVHZ Approved asphalt shingle, non-structural metal, wood shakes & shingles or slate.
6.4.2 System E(2):
Base underlayment mechanically fastened to deck, top layer adhered
Deck Type 1:
Wood, Non -Insulated
Deck Description:
Min.19/32" plywood or wood plank
Base Layer:
One or more plies of PALISADE' with minimum 4" wide head laps and minimum 6" wide end
laps, mechanically fastened to deck.
Fastening:
HVHZ Approved nails and tin caps 6" o.c. at lap and three equally spaced staggered rows 12"
o.c. in the field.
Top Layer:
Tamko TW Metal and Tile Underlayment (NOA 12-0406.07), GAF UnderRoof 2 (NOA 13-
1104.11) or CertainTeed Flintlastic SA Cap (NOA 14-0724.16), self -adhered to the base layer.
See current FBC HVHZ approval for installation guidelines and limits of use of top layer.
Surfacing:
HVHZ Approved asphalt shingle, non-structural metal, wood shakes & shingles, slate or tile.
Note:
For tile applications, AH1 shall verify that top layer underlayments listed herein hold current
HVHZ Product Approval and/or Miami -Dade NOA for use as a tile underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named
CIA entity for information on plants covered under Rule 61G20-3 QA requirements.
9. QUALITY A58URANCE ENTITY:
Intertek Testing Services NA Inc. —
ETL/Warnock Hersey— QUA1673; (90S) 678-4913
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C.
Cen ficote of Authorization 09.503
Evaluation Report S19030.07.09-R2
FL5325-R6
Revision 2: 04/29/2015
Page 5 of 5