HomeMy WebLinkAboutReview CommentsPlanning & Development Services Building &Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 3116 Nw Radcliffe Way City / State / Zip: Palm City, FI 34990 Parcel 4425-703-0028-000/7 Zoning: PUD REVIEW COMMENTS Page 1 Owner(s): Standard Pacific Of Florida Jurisdiction: SAINT LUCIE COUNTY Lot#: 23 Block: APPLICATION INFORMATION Permit Number: 1607-0482 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Scott David Harala Business Name: Standard Pacific Of Florida Gp Inc Business Addr: 825 Coral Ridge Rd City / State / Zip: Coral Springs, FI 33071 REVIEWS AND COMMENTS ReviewTyoe Status Reviewed By ADDRESSING ASSIGNMENT COMPLETE Lydia Galbraith Comment: DOCUMENTS MISSING 7/26/2016 Comment: ENVIRONMENTAL REVIEW Comment: FRONT COUNTER REVIEW Comment: PLANS EXAMINER REVIEW Comment: 8/9/2016 8/9/2016 Comment: Comment: 8/9/2016 Comment: 8/9/2016 Comment: 8/9/2016 PENDING Karen Nielsen VEG PERMIT IN BIN UNDER "S" STANDARD COMPLETE Ben Balcer COMPLETE Karen Nielsen Automatic Sprinkler System? No Fax Number: 954-575-7324 M Email: Scott.Harala@Calatl.Com Date Started Date Completed Date Released 7/27/2016 7/27/2016 7/27/2016 7/22/2016 7/2212016 7/25/2016 7/25/2016 7/22/2016 7/22/2016 7/22/2016 INCOMPLETE William Durden 8/9/2016 - U-FACTOR AND SHGC ON THE ENERGY CALC'S ARE HIGH PLEASE CORRECT THE U-FACTOR AND THE SHGC SHOWING COMPLIANCE WITH CHAPTER 4 SECTION 402.1.1 OF THE 2014 ENERGY CODE FIFTH EDITION. AREA WEIGHTED AVERAGE FOR THE OVERHANG AND THE SHGC DO NOT MEET THE REQUIREMENTS OF R405.5.3.4 FBCEC. PLEASE SEE THE SHGC FOR THE GLAZED OPENINGS. - PLEASE SUBMIT THE ENERGY PERFOMANCE SHEETS OR SUBMIT A THE NFRC FENSTRATION MANUFACTURE CERTIFICATE FOR THE U-FACTOR AND THE SHGC FOR EACH GLAZED OPENING SHOWING COMPLIANCE WITH CHAPTER 4 SECTION 402.1.1 OF THE 2014 ENERGY CODE FIFTH EDITION. PRODUCT INFORMATION FOR N.O.A. #11-1013.4 IS AN OUTDATED APPROVAL NUMBER. PLEASE SUBMIT CORRECT APPROVAL NUMBER FOR THE PGT 700 WINDOWS. SEE (5) (C) OF 9B-72 STATE PRODUCT APPROVAL OF THE FLORIDA ADMINISTRATIVE CODE. PRODUCT INFORMATION FOR N.O.A. 11-0922.01 IS AN OUTDATED APPROVAL NUMBER. PLEASE SUBMIT CORRECT APPROVAL NUMBER FOR THE PGT 700 WINDOWS. SEE (5) (C) OF 913-72 STATE PRODUCT APPROVAL OF THE FLORIDA ADMINISTRATIVE CODE. Planning & Development Services Building &Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462-6443 REVIEW COMMENTS Page 2 Comment: PRODUCT REVIEW AFFIDAVIT CALLS OUT METAL ROOFING MATERIAL, ENERGY CALC'S CALL OUT 8/9/2016 BARREL TILE ROOF SYSTEM. PLEASE CORRECT DOCUMENTS TO REFLECT THE ACTUAL CONDITIONS TO BE INSTALLED. SEE SECTION 107 OF THE 2014 FLORIDA BULDING CODE. Comment: PLANS AND ENERGY CALC'S CALL OUT BARREL TILE ROOF, THE PRODUCT REVIEW AFFIDAVIT CALLS OUT 8/9/2016 A METAL ROOF. PLEASE CORRECT DOCUMENTS TO REFLECT THE ACTUAL CONDITIONS TO BE INSTALLED. SEE SECTION 107 OF THE 2014 FLORIDA BULDING CODE. Comment: • PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE 8/9/2016 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. ZONING REVIEW COMPLETE Lydia Galbraith 7/27/2016 7/27/2016 7/27/2016 Comment: