HomeMy WebLinkAboutReview CommentsPlanning & Development Services
Building &Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462.2172 Fax:(772)462-6443
PROPERTY INFORMATION
Address: 3116 Nw Radcliffe Way
City / State / Zip: Palm City, FI 34990
Parcel 4425-703-0028-000/7
Zoning: PUD
REVIEW COMMENTS
Page 1
Owner(s):
Standard Pacific Of Florida
Jurisdiction: SAINT LUCIE COUNTY
Lot#: 23 Block:
APPLICATION INFORMATION
Permit Number: 1607-0482 Stories:
Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS)
CONTRACTOR INFORMATION
Contractor Name: Scott David Harala
Business Name: Standard Pacific Of Florida Gp Inc
Business Addr: 825 Coral Ridge Rd
City / State / Zip: Coral Springs, FI 33071
REVIEWS AND COMMENTS
ReviewTyoe Status Reviewed By
ADDRESSING ASSIGNMENT COMPLETE Lydia Galbraith
Comment:
DOCUMENTS MISSING
7/26/2016 Comment:
ENVIRONMENTAL REVIEW
Comment:
FRONT COUNTER REVIEW
Comment:
PLANS EXAMINER REVIEW
Comment:
8/9/2016
8/9/2016
Comment:
Comment:
8/9/2016
Comment:
8/9/2016
Comment:
8/9/2016
PENDING Karen Nielsen
VEG PERMIT IN BIN UNDER "S" STANDARD
COMPLETE Ben Balcer
COMPLETE Karen Nielsen
Automatic Sprinkler System? No
Fax Number: 954-575-7324
M
Email: Scott.Harala@Calatl.Com
Date Started Date Completed Date Released
7/27/2016 7/27/2016 7/27/2016
7/22/2016
7/2212016 7/25/2016 7/25/2016
7/22/2016 7/22/2016 7/22/2016
INCOMPLETE William Durden 8/9/2016
- U-FACTOR AND SHGC ON THE ENERGY CALC'S ARE HIGH PLEASE CORRECT THE U-FACTOR AND THE
SHGC SHOWING COMPLIANCE WITH CHAPTER 4 SECTION 402.1.1 OF THE 2014 ENERGY CODE FIFTH
EDITION.
AREA WEIGHTED AVERAGE FOR THE OVERHANG AND THE SHGC DO NOT MEET THE REQUIREMENTS OF
R405.5.3.4 FBCEC. PLEASE SEE THE SHGC FOR THE GLAZED OPENINGS.
- PLEASE SUBMIT THE ENERGY PERFOMANCE SHEETS OR SUBMIT A THE NFRC FENSTRATION
MANUFACTURE CERTIFICATE FOR THE U-FACTOR AND THE SHGC FOR EACH GLAZED OPENING SHOWING
COMPLIANCE WITH CHAPTER 4 SECTION 402.1.1 OF THE 2014 ENERGY CODE FIFTH EDITION.
PRODUCT INFORMATION FOR N.O.A. #11-1013.4 IS AN OUTDATED APPROVAL NUMBER. PLEASE SUBMIT
CORRECT APPROVAL NUMBER FOR THE PGT 700 WINDOWS. SEE (5) (C) OF 9B-72 STATE PRODUCT
APPROVAL OF THE FLORIDA ADMINISTRATIVE CODE.
PRODUCT INFORMATION FOR N.O.A. 11-0922.01 IS AN OUTDATED APPROVAL NUMBER. PLEASE SUBMIT
CORRECT APPROVAL NUMBER FOR THE PGT 700 WINDOWS. SEE (5) (C) OF 913-72 STATE PRODUCT
APPROVAL OF THE FLORIDA ADMINISTRATIVE CODE.
Planning & Development Services
Building &Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462.2172 Fax:(772)462-6443
REVIEW COMMENTS
Page 2
Comment:
PRODUCT REVIEW AFFIDAVIT CALLS OUT METAL ROOFING MATERIAL, ENERGY CALC'S CALL OUT
8/9/2016
BARREL TILE ROOF SYSTEM. PLEASE CORRECT DOCUMENTS TO REFLECT THE ACTUAL CONDITIONS TO
BE INSTALLED. SEE SECTION 107 OF THE 2014 FLORIDA BULDING CODE.
Comment:
PLANS AND ENERGY CALC'S CALL OUT BARREL TILE ROOF, THE PRODUCT REVIEW AFFIDAVIT CALLS OUT
8/9/2016
A METAL ROOF. PLEASE CORRECT DOCUMENTS TO REFLECT THE ACTUAL CONDITIONS TO BE
INSTALLED. SEE SECTION 107 OF THE 2014 FLORIDA BULDING CODE.
Comment:
• PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE
8/9/2016
SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED
DOCUMENTS.
ZONING REVIEW
COMPLETE Lydia Galbraith 7/27/2016 7/27/2016 7/27/2016
Comment: